Wall Mounted Mini Split
Heat Pump
Air Conditioner
OPERATING AND INSTALLATION MANUAL
Model: KFHHP-18-ID / KFHHP-18-OD
Indoor Unit.
Outdoor Unit.
Thank you for selecting Soleus Air. To ensure proper
operation, please read this manual and keep it for
future reference.
Download from Www.Somanuals.com. All Manuals Search And Download.
Use and Maintenance
◆Precautions on Use
Carefully read the following precautions before use
Warning
★In case of malfunction (e.g. burnt
smell), cut off the power supply
immediately and then contact the
Authorized Service Center (626-820-
1436).
★To avoid electric shock. Never
operate the unit with wet hands.
★Do not cut or use damaged power
cords and control lines.
The malfunction continues, the air
conditioner may be damaged.
★Never use unapproved wire or
controls.
★There is a possibility of electric
shock or fire. To avoid electric shock
or fire, use an approved circuit.
★Disconnect the power supply if
you plan to discontinue using the unit
for the season.
★Please turn off the power before
cleaning the air conditioner.
★Rated voltage of this air
conditioner 208-230V~, with a
tolerable fluctuation at 10%. Any
other voltage will cause damage to
the unit.
★This unit requires a circuit breaker
as specified by your building code.
cut off the
power
- 1 -
Download from Www.Somanuals.com. All Manuals Search And Download.
◆Precautions on Use
★Grounding: The unit must be
properly grounded.
★Set the room temperature appropriately.
The difference
between indoor
and outdoor
temperature
shall be 40 °F.
★To avoid the possibility of fire.
★Close all doors & windows for
★Never block the air inlet or outlet
Never store chemicals or flammable
items within 3.28 feet of the unit.
efficient operation.
of indoor and outdoor unit.
Otherwise it may cause fire or
explosion.
★To avoid damage make sure the
★To avoid damage never place any ★Call an authorized service repair
mounting of the unit is secure.
object on the condensing unit.
man if your unit malfunctions.
- 2 -
Download from Www.Somanuals.com. All Manuals Search And Download.
◆Precautions on Use
★Adjust the air flow and direction properly. When the air conditioner is running, you can press the SWING key on
the remote control to adjust the guide louver and change the direction of air flow.
★To avoid harm to your pets or plants, never direct the
★To avoid injury or damage, never stick your fingers or
airflow at them.
any other object into the unit.
★To avoid damage or electric shock, never spray liquid
★To avoid carbon monoxide poisoning, never direct the
onto the unit.
airflow near or at your gas top burners.
★To avoid any harm to your health, do not blow the cold
air on your body for long periods or decrease the room
temperature too low.
★This air conditioner cannot be used for drying clothes
or refrigerating foods.
- 3 -
Download from Www.Somanuals.com. All Manuals Search And Download.
◆Specifications and Technical Data
Model
Function
KFHHP-18-ID / KFHHP-18-OD
Heating and Cooling
18000 / 5300 (1400-6000)
20000 / 6000 (1100-7000)
208-230V~
60Hz
Cooling capacity(BTU/hr) & (Watts)
Heating capacity(BTU/hr) & (Watts)
Rated voltage
Rated Frequency
Cooling/Heating rated current(A)
Cooling/Heating rated power(W)
Cooling/Heating power input(W)
SEER
10.6/10.6
2440/2440
1350/1800
13.25
EER/COP(W/W)
3.93/3.22
HSPF
8.5
Recycling Air Volume(m3/h
Factory Charge 410A (lbs.)*
Noise (Indoor/Outdoor) dBA
)
800
R410A 3.9 lbs
50/57
Maximum Vertical
Maximum Length
16.4 ft
Height Differential
32.8 ft
Net Weight (Indoor/Outdoor) (lb)
28.7/130.1
Indoor unit :40.16” ×8.98” ×12.20”
Outdoor unit:37.40” ×13.39” ×26.93”
Dimensions (Indoor/Outdoor)
(WxDxH)(inch)
Connection Pipe:
Length (ft)
26.25
Gas additional charge(oz/ft)
0.21
Liquid Pipe (mm)
Φ9.52(5/8”)
Φ16(3/8”)
26.25
Outer Diameter
Max Distance
Gas Pipe (mm)
Height (ft)
Length (ft)
49.21
All above are tested and certified to ETL specification. Among them, the cooling capacity, heating
capacity and noise level are tested before shipment.
In case of any change in performance parameters, the data provided on nameplate shall prevail.
Test the maximum input power under maximum cooling condition (89.6°F /73.4°F, 109.4°F /78.8°F)
and maximum heating condition (44.6°F /-, 75.2°F /69.8°F).
Working temperature range
Indoor side DB/WB(°F)
Outdoor side DB/WB(°F)
Maximum cooling
Minimum cooling
Maximum heating
Minimum heating
89.6 / 73.4
69.8 / 59
80.6 / -
109.4 / 78.8(T1)
64.4 / -
75.2 / 64.4
19.4 / 17.6
68 / -
- 4 -
Download from Www.Somanuals.com. All Manuals Search And Download.
◆Instructions for Use
Principle and Special Functions during Cooling Mode
Principle:
The air conditioner absorbs heat from indoor air and transmits it outdoors for discharge, hence to decrease the indoor
ambient temperature. The cooling capacity decreases with the rise of outdoor ambient temperature.
Anti-freeze Function:
If the air conditioner is running under low-temperature cooling mode, frost will appear on the surface of indoor heat
exchanger. When the temperature of indoor heat exchanger is decreased to 32°F or below, the microcomputer of indoor
unit will stop the compressor to protect the complete unit. A low ambient kit [not supplied] is required to make unit
operate at lower than 32°F.
Principle and Special Functions under Heating Mode
Principle:
*
The air conditioner absorbs heat from outdoor air and transmits it indoors for emission, hence to increase the
air temperature in the room. The heating capacity decreases with the reduction of the outdoor ambient
temperature.
*
*
It takes only a short time for this type of hot air circulating system to increase the indoor temperature.
Use this air conditioner with other heating equipment if the outdoor temperature is extremely low.
Defrost:
*
When the outdoor temperature is low but the humidity is high, the heat exchanger of outdoor unit may freeze
after the air conditioner has run for a period of time. This will decrease the heating effect. In this case, auto
defrost function will be activated and the heating mode will temporarily stopped for 8-10 minutes.
Both the indoor fan and outdoor fan will be stopped during auto defrost.
During defrost, the indicator on indoor unit will blink and steam might flow from the indoor unit. This is
caused by quick defrost other than fault.
*
*
*
Heating mode will automatically resume upon completion of defrost process.
Anti-freeze Function:
Under heating mode, if the indoor heat exchanger fails to reach a specific temperature under the following conditions,
the indoor fan will not be started, so as to avoid blowing of cold air (within 3 minutes):
1. Start of heating mode.
2. End of auto defrost.
3. Heating under low-temperature environment.
★Conditions that the Air Conditioner will be unable to run normally:
The protection device will be activated within such temperature range as specified below, so that the unit will be shut
down.
Outdoor temperature
over 75.2°F
Outdoor temperature
below 19.4°F
Room temperature
over 80.6°F
Outdoor temperature
over 109.4°F
Room
temperature
below 64.4°F
Cooling
Mode
Dehumidify
Mode
Heating Mode
Room temperature
below 69.8°F
If the unit is run for extended periods under high humidify (80% +) condensation will be present at the outlets.
- 5 -
Download from Www.Somanuals.com. All Manuals Search And Download.
◆Description of Air-Conditioner Components
(1) Front Panel
(2) Guide Louver
(3) Remote Sensor
(4) Wall Pipe
(5) Wrapping Tape
(6) Drainage hose
(7) Connection pipe
- 6 -
Download from Www.Somanuals.com. All Manuals Search And Download.
◆Remote Control Operation
Function-Remote control
Note:
•
•
•
Don't drop the remote control.
Don't place the remote control in a location exposed to direct sunlight.
When the unit is restarted after stopped, it will automatically resume its last running mode, and the
outdoor unit will start there after.
MODE Button:
TEMP+ TEMP- Button:
When the unit is
turned on, press this
button. The AUTO,
COOL, DRY, FAN or
HEAT mode can then
be selected.
Under the COOL, DRY,
FAN or HEAT mode,
press these two buttons
could set the temperature,
the temp. setting range is
60.8°F -86°F, the temp.
can be memorized under
each mode.
FAN SPEED Button:
When the unit starts up,
under the AUTO, COOL,
FAN or HEAT mode, press
this button and select Auto
fan, Low fan, Middle fan,
High fan. At DRY mode,
the fan speed runs at Low
fan speed. The FAN
CLOCK Button:
When pressing this
button once, the icon of
CLOCK will flash, and
can be adjusted. At
SPEED can be memorized
under various modes.
CLOCK adjustment,
press the TIME+ once,
the ones placed on the
minute will be increased
1, and continuously press
1 sec above, the tens
place on the minute will
be increased 1 in every
half second. When
SLEEP Button:
pressing the TIME-, the
ones placed on the
Under COOL, DRY &
HEAT mode, press the
button once to start the
SLEEP function, when
pressed again, it will stop.
minute will be decreased
1, and continuously press
1 sec above, the tens
place will be decreased 1
in every half second.
After adjusting please
press the CLOCK button
again for confirming.
- 7 -
Download from Www.Somanuals.com. All Manuals Search And Download.
◆Remote Control Operation (Continued)
Liquid Crystal Display.
It shows all set contents.
SWING Button:
ON/OFF Button
Press once to have louvers
swing [oscillate]. Press
twice in one second the
panel light will turn on.
Press twice again and the
light will turn off.
Press ON.
Press OFF.
T-ON Button.
When pressing this button
once, enter into T-ON
setting, the icon of T-ON
flash, every press of
T-OFF Button
TIME+, the time of T-ON
will be increased 1min.
When continuously press 1
sec above, the tens placed
on minute will be
increased 1, every press of
TIME- will be decreased 1
minute, when continuously
press 1 sec above, the tens
placed on minute will be
decrease 1 in every half
second, and it goes round
with 12 hours.
Press this button once to
enter into T-OFF
setting, the icon of T-
OFF will flash, the T-
OFF button is available
in ON or OFF mode, the
setting method is the
same with T-ON.
CANCEL Button
Pressing this button will
cancel timer.
TIME+ TIME- Button
Function instruction please
refer to T-ON button, T-
OFF button, CLOCK
button.
- 8 -
Download from Www.Somanuals.com. All Manuals Search And Download.
◆How to Insert Batteries
1. Remove the cover from the back of the remote control.
2. Insert the two batteries (Two AAA dry-cell batteries).
3. Re-attach the cover.
NOTE:
• Don’t mix different batteries.
• Remove batteries when not in use for a longtime.
• The batteries can be used for about one year.
• Keep remote at least 3.28 feet from TV’s and other electronic devices.
When the wireless remote control is lost or broken, please use the manual switch,
It will start in AUTO mode, the temperature setting and fan speed cannot
be changed. Please use a ball point pen or similar device to operate switch.
Turn on the unit: By pressing the Manual Switch the unit will start in AUTO automatically.
The microcomputer will adjust to the indoor temperature by selecting (COOL, HEAT, FAN), in order to
achieve a comfortable condition.
•
Turn off the unit: When unit is running, press the manual switch STOP button, the unit will stop running.
- 9 -
Download from Www.Somanuals.com. All Manuals Search And Download.
◆Cleaning and Maintenance
• Be sure to cut off the power supply before cleaning the air conditioner; otherwise electric shock might
occur.
• Liquids on the air conditioner may cause the risk of electric shock. Make sure not to spray wash your
air conditioner in any case.
• Volatile liquids such as thinner or gasoline will cause damage to the appearance of air conditioner.
(Only use soft dry cloth or wet cloth soaked with neutral detergent to clean the air conditioner
cabinet).
Clean the front panel (Don’t remove the front panel when
cleaning).
When the indoor unit front panel is dirty, please use the cloth which is soaked in the warm water
under 104°F, then dry it and wipe the dirty places.
NOTE:
There are microcomputer components and circuit board on the displayer of the indoor unit front
panel, never let it dip in the water.
Clean filter (Approximately every three months)
Note: Clean the air filter more frequently if the air conditioner is used under dusty environment. To avoid
injury, do not touch the fins of indoor unit with your finger after removing
the filter.
① Remove the air filter
Hold the groove on two ends of the front panel. Along arrow direction,
pull with force to open the front panel for an angle. Then pull the air filter
downward for removal. See Fig. 5 (a, b, c)
② Clean the air filter
Wash the filter with vacuum cleaner or water. If the filter is too dirty,
wash with warm water (below 113°F) with neutral detergent. Then air dry it
at a cool place.
Note: To avoid discoloring or deformation, do not wash
with hot water over 113°F. Never dry on the fire, as the
filter may be burnt or deformed.
- 10 -
Download from Www.Somanuals.com. All Manuals Search And Download.
◆Cleaning and Maintenance
③Installing the air filter
Mount the air filter in the direction of the arrows. Then, clamp the cover
of front panel securely.
Check before Seasonal Use
① Check the air inlet/outlet on indoor and outdoor units for any blockage.
② Check the grounding cable for reliability.
③ Check the batteries of remote control for replacement.
④ Check the mounting frame of outdoor unit for damage. If damaged,
please contact the Authorized Service Center.
Check after Seasonal Use
①Cut off the power supply to air conditioner.
②Clean the filter and the indoor/outdoor unit.
③Clear off the dust and foreign particles on outdoor unit.
④If the outdoor unit is rusted, paint on the rusty portion to prevent corrosion.
- 11 -
Download from Www.Somanuals.com. All Manuals Search And Download.
◆Trouble-Shooting
Do not repair by yourself. Incorrect repair may cause electric shock or fire, so please contact the
Authorized Service Center for professional repair.
Fault
Cause Analysis
Air conditioner does not run upon immediate restart after a To protect the air conditioner upon immediate restart
stop.
after a stop, the microcomputer control will delay the
unit for 3 minutes before the air conditioner will run.
Air conditioner blows out a bad odor when it is initially
started.
The air conditioner itself has no bad odor. If any, it is the
bad odor accumulated from the environment.
Solution: Clean the air filter (Refer to Page 10). If the
problem persists please call the Authorized Service
Center.
You may hear a “water flowing” noise when the air
conditioner is running.
The noise you hear is the refrigerant in the system.
Sometimes a thin fog will flow out of the outlet when the air
conditioner is running under cooling mode.
This might occur when indoor temperature and humidity
are high. This is because the indoor air is quickly cooled
down.
After a period of time, the fog will disappear with the
decrease of indoor temperature and humidity.
You may hear a slight crack when the air conditioner is
started or stopped.
This is the sound of friction caused by expansion of panel
or other parts due to the change of temperature.
- 12 -
Download from Www.Somanuals.com. All Manuals Search And Download.
◆Trouble-Shooting
Fault
Cause Analysis
Air conditioner does not run.
•
•
•
Power failure?
Circuit protection device tripped?
The voltage is too high or too low?
(
Refer to Page 15). (To be tested by
professional technicians).
•
Timer function is correctly used?
(
Refer to Page 7).
Air conditioner is poor in cooling (or heating) effect.
•
•
•
Is temperature setting proper? (
Is the air inlet or outlet of outdoor unit blocked?
Is the air filter clogged by dust? (
10).
Refer to Page 7)
Refer to Page
•
•
•
Are all doors and windows closed?
Is air flow set to “LOW FAN”?
Is any other heating source in the room?
Remote control cannot execute control.
•
Remote control sometimes cannot execute control if
the air conditioner is subject to abnormal interference
or frequent switching of functions. To resume normal
operation, just pull out the battery and reinsert it
properly.
•
•
Is remote within receivable range or blocked by any
obstacles? (
Refer to Page 7)
Check the battery in remote control for power level.
If low power, replace the battery. (
9)
Refer to Page
•
Is the remote control is damaged.
Water leaks from indoor unit.
Water leaks from outdoor unit.
•
•
•
Room air humidity is excessively high.
Condensation water overflowing.
Connection of indoor unit drain pipe is leaking.
•
•
•
Under cooling mode, water might condense on pipe
or pipe joint due to cooling.
Defrosted water flows out under heating or defrost
(auto defrost) mode.
Under cooling mode, water attached on heat
exchanger will drip.
Indoor unit has unusual noise.
•
•
The sound that the fan or compressor relay is
switching (close/open).
Air conditioner may give out sounds under defrost
or when it is stopped. This is caused due to inverse
flow of refrigerant in the unit.
- 13 -
Download from Www.Somanuals.com. All Manuals Search And Download.
◆Trouble-Shooting
Fault
Cause Analysis
No air blows out from indoor unit.
•
•
When the temperature of indoor heat exchanger is
low during heating process, the indoor unit will stop
blowing to prevent blowing of cold air (within 3
minutes).
Under dehumidify mode, the fan of the indoor unit
might be stopped to prevent evaporation of
condensing water and inhibit the rise of temperature.
Moisture exists on outlet grill.
•
If the unit is run for extended periods under high
humidity condensation will be present at the outlets.
In the event of any of the following, please contact Authorized
Service Center.
- 14 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Services
◆Precautions on Installation
Important Caution
1. The air-conditioning unit must be installed by professional technicians in accordance with the state and local
codes.
2. Contact the local installation and service agency before installation.
3. For relocation of the air conditioner to another position, please contact the local Authorized Service Center.
Basic Requirements for Installation Position
Installation at the following places may cause failure of the air conditioning unit. Please contact installation and service
agency if the installation at such places cannot be avoided.
•
Any environment where the strong heat, steam, flammable or explosive gas exists or the volatile matters are
distributed in the air.
•
•
•
•
•
Any place close to high-frequency facilities, e.g. welding machine, medical equipment.
A region with saline-sodic soil near the ocean.
A place where the air contains oil (mechanical oil).
A place with sulphide gases (such as sulphur spring).
Any environment with special conditions.
Indoor unit Selection of Installation Position
1. The air inlet and air outlet must be away from obstacles to ensure that airflow can reach every corner of the room.
2. Choose a position where condensation water can be easily discharged and the outdoor unit can be easily connected.
3. Install the unit in a place where the children can not reach.
4. Choose a place where the weight of indoor unit can be withstood and operating noise and vibration are not
increased.
5. Ensure sufficient clearance and space for service and maintenance; Ensure the indoor unit is at least 2.3m from the
floor.
6. Choose a position at least 3.28 feet from any TV, sound system or other household electric appliances.
7. Choose a place so that the air filter can be easily pulled out.
8. Ensure the installation of indoor unit is in conformity with the requirements of installation dimension drawing.
(
page 17)
Outdoor unit Selection of Installation Position
1. The place where the noise and air flow from the fan will not affect the neighbors, animals or plants.
2. Ensure good ventilation of outdoor unit.
3. No obstacles near the outdoor unit obstructing the air intake and air exhaust of the unit.
4. The installation position shall be able to withstand the weight and vibration of the outdoor unit and ensure safe
installation.
5. Select a dry place but not exposed to direct sunshine or strong wind.
6. Ensure that the outdoor unit is installed in compliance with installation dimensions for easy repair and
maintenance. (
page 17)
7. Height difference of fitting pipes shall be within 16.4 feet and the length of fitting pipe shall be within 32.8 feet.
8. Install the unit in a place where the children can not reach.
9. A place not affecting the public passage or city view.
Electrical Safety Requirements
1. The power supply must be of rated voltage via special circuit for air conditioning. The wire size of power lines
shall conform to code.
2. Applicable voltage range: the normal operation range of voltage is 90%~110% of rated voltage.
3. Do not pull the power line with force.
- 15 -
Download from Www.Somanuals.com. All Manuals Search And Download.
◆Precautions on Installation
4. Ensure safe grounding and the grounding wire shall be connected with the special grounding equipment of the
building and must be installed by professional technicians. In the fixed line there must be an electrical leakage
protection switch and an air switch with sufficient capacity. The air switch shall also have the magnetic tripping
and thermal tripping functions to achieve protection of both short-circuit and overload.
5. The minimum clearance between air conditioner and flammable surface is 1.5m.
Grounding Requirement
1. This air-conditioning unit is a Class I electrical appliance, reliable grounding measures must be taken for it.
2. The double color (yellow and green) cable inside the air conditioner is for grounding and shall not be used for
other purposes nor can it be cut. Do not tighten with tapping screw; otherwise electric shock is possible.
3. The ground resistance shall be in conformity with the state and local codes.
4. The unit must be properly grounded. It is prohibited to connect the grounding wire to the following items:
①Water Supply Pipe
②Gas Pipe
③Sewage Pipe
④Other positions that are considered to be unreliable by professionals.
- 16 -
Download from Www.Somanuals.com. All Manuals Search And Download.
◆Installation Dimension Drawing
- 17 -
Download from Www.Somanuals.com. All Manuals Search And Download.
◆Install Indoor Unit
Installing Wall-Mounting Frame
1. Level with plumb line or spirit level. As the drain outlet is on left side, it is better that the left side shall be lower
when adjusting the wall-mounted board.
2. Use screws to secure the wall-mounting frame on
the wall.
3. After installation is completed, manually pull
the wall-mounting frame to check if it is secured.
The mounted frame shall be able to withstand the
weight of an adult (132 lbs) and the fixing screws
shall have relatively even stress.
Wall Opening and Wall Pipe Installation
1. After deciding the hole position of the fitting pipe according to
Figure 6, drill a declining hole (Φ65)
2. To prevent the fitting pipe and the cable passing through the wall
from being harmed, it is necessary to install a wall pipe.
Installing Drainage Pipe
1. The flexible drainage pipe must descend to allow smooth running
of water.
2. Pay attention not to allow twists, ridges and distortion of the
drainage pipe in the layout and not to immerse the outlet in water.
3. Extended part of flexible drainage pipe passing through the
indoor unit must be wrapped by thermal insulation material.
Connection of Indoor and Outdoor Cables
1. Pull open the front panel from the above. (
page 10 Fig5 (a))
2. Unscrew the screw fixing the covering plate of terminal board.(Fig 7)
3. Pass the power cable through a separate cable duct on the back of
indoor unit and pull it out from the front.
4. Connect the Neutral wire of the power connection cables to the “N(1)”
terminal of the terminal board, connect the Signal wire to the “2”terminal
and connect the Live wire to the“3”terminal and connect the grounding wire
to the“ ”terminal (See Fig. 8).
5. Place the section of power cable with protective pipe into pressing groove and
close the cover plate. Tighten the fixing screws to clamp the connecting cable.
6. Install the front panel back into position
- 18 -
Download from Www.Somanuals.com. All Manuals Search And Download.
◆Install Indoor Unit
Notes:
If the connecting cable is not long enough, please contact your distributor for a piece of special cable with
sufficient length. No joints are allowed in the middle of the cable.
• Be sure to connect the cable correctly. Incorrect connection will cause fault to some electrical parts.
• Tighten the terminal screw.
• After tightening the screw, gently pull the cable for tightness.
• Incorrect connection of grounding cable might cause electric shock.
• Be sure to fit the junction cover plate securely and press it closely against connecting cable. Improper
fitting of junction over plate might allow dust or water to enter or expose connecting terminal directly
under the external force, fire or electric shock might occur.
Installing the Indoor Unit
• Fitting pipe can come out from one of four directions, i.e. right, rear right, left and rear left.
1. When laying the pipe (line) at the left or right side
cut as needed the extra part of the fitting pipe left at the
tube-exit plate of the unit base. (See Fig. 9).
(1) When only drawing out the power line, cut extra part 1.
(2) When drawing out the connecting pipe and the
electrical line, cut extra parts 1 & 2 (or 1, 2 & 3).
2. Pull out the fitting pipe from bottom case. Use adhesive tape
to bond the fitting pipe, electrical cable and drain hose
properly together and then pass them through the fitting pipe hole
(See Fig. 10).
3. Hang the claws at the rear side of the indoor unit to the hook on
the wall-mounting frame. Move the unit left and right to see if
it is steady. (See Fig 11)
4. The installation height of the indoor unit must be at least 78.74in.
Installing Connecting Pipe
1. The taper end of the connecting pipe must be in line with
the corresponding tape face of the valve joint.
2. Use enough force to manually tighten the nut of the connecting pipe
and then use spanner to tighten the nut.
Tightening Torque
Hexagon Nut (mm)
(N.m)
φ6.
φ12
15~20
50~55
Notes:
Connect the connecting pipe to the indoor unit first and then connect it to the outdoor unit. Pay attention to
the bending and layout when preparing the connecting pipe in order not to harm it. Do not screw the joint
nut too tight, otherwise leakage will occur.
- 19 -
Download from Www.Somanuals.com. All Manuals Search And Download.
◆Install Outdoor Unit
Power Cable Connection
1. Remove the handle at the right side plate of the outdoor unit
(one screw).
2. Remove the cable clamp, connect the power connection cable
with the terminal at the row of connection and make the
connection. The fitting line distributing must be consistent
with the indoor unit.
3. Use cable clamp to make the cable connection cable.
4. Confirm the fitting lines are properly installed.
5. Install the handle (fixed by one screw).
Notes:
•
Improper line connection may cause failure of some electrical
components and parts
•
When fixing the cable, a certain degree of play shall be
maintained for the cable between the connection point and the
fixing point.
Vacuum – Pumping and Leakage Inspection
1. Remove the nut cover at the shutoff valve.
2. Align with the center of the fitting pipe and manually
tighten the conical nut sufficiently.
3. Use spanner to tighten the conical nut.
4. Remove the liquid valve cap, the gas valve cap and the
nut of refrigerant charging mouth.
5. Use inner hexagon spanner to twist off the liquid valve
body and at the same time use screwdriver to open the valve
core of the liquid valve. Now gas shall flow out.
6. After gas continues flowing out for about 15 second and
refrigerant gas begins to flow out, close the valve core and
tighten the nut of refrigerant charge mouth.
7. Completely open the valve body of the liquid valve and the
gas valve. (See Fig 12)
8. Turn and tighten the valve cap, then use soap water or a leak
detector to check if there is gas leakage at the outdoor and
indoor units and the pipeline connections.
9. If conditions permit, use a vacuum pump to exhaust air in
the unit from the valve core. (See Fig 13)
Draining of Condensate Water of Outdoor Unit
When the air-conditioning unit is in the heating mode, the
condensate water generated at the outdoor unit and the water
generated by defrosting shall be drained through the drainage
pipe to proper place.
Installation methods: As shown in Figure, insert the drainage
joint of the outdoor unit into the Φ25 hole on the base plate.
Connect the drainage pipe to the drainage mouth so as to drain
the condensate water and water generated by defrosting to
proper place.
- 20 -
Download from Www.Somanuals.com. All Manuals Search And Download.
◆Install Outdoor Unit
Check Items After Installation
Check Items
Problems Owing to Improper Installation
Is the installation reliable?
The unit may drop, vibrate or make noises
May cause unsatisfactory cooling (heating)
effect
Has the refrigerant gas leakage been checked?
Is the thermal insulation of the unit sufficient?
Is the drainage smooth?
May cause condensation and water dripping
May cause condensation and water dripping
Does the power supply voltage accord with the
rated voltage specified on the nameplate?
The unit may break down or the components
may be burned out
The unit may break down or the components
may be burned out
Are the lines and pipelines correctly installed?
Has the unit been safely grounded?
Risk of electrical shock or electrocution.
Are the models of lines in conformity with
requirements?
The unit may break down or the components
may be burned out
Are there any obstacles near the air inlet and outlet The unit may break down or the components
of the indoor and outdoor units?
may be burned out
Have the length of refrigerating pipe and
refrigerant charge amount been changed?
It is not easy to measure the charge amount of
refrigerant.
Test Run
1. Preparation of Test Run
(1) Do not switch on the power before all installation work is completed.
(2) Confirm that the control line is correctly installed and all electrical lines are firmly connected.
(3) Open the shutoff valves of the big and small lineset.
(4) Remove all foreign articles, especially metal scraps, line ends and forceps, from the unit.
2. Method of Test Run (
page 17)
(1) Connect to the power supply, press the“ON/OFF”key on the remote controller, and the
air conditioning unit starts to operate.
(2) Press the Mode key, select the operating modes such as cooling and fan, and observe if the operation
is normal.
- 21 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical Schematic Diagram
◆Electrical Schematic Diagram (Indoor Unit)
- 22 -
Download from Www.Somanuals.com. All Manuals Search And Download.
◆Electrical Schematic Diagram (Outdoor Unit)
- 23 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Warranty
Soleus International Inc. warrants the accompanying Soleus Air Wall Mounted Mini Split Heat Pump Air
Conditioner (KFHHP-18-ID/KFHHP-18-OD) to be free of defects in material and workmanship for the
applications specified in its operation instruction for the period of parts specified below.
5 YEARS FOR COMPRESSOR
1 YEAR FOR OTHER COMPONENTS
This warranty shall not apply to broken or marred cabinets, accessories, knobs, filters or routine
maintenance. This warranty does not apply to uncrating, setup, installation, removal of the product for
repair or reinstallation of the product after repair.
This warranty does not apply to repairs or replacements necessitated by any cause beyond the control of
Soleus International including, but not limited to, any malfunction, defect or failure caused by or resulting
from unauthorized service or parts, improper maintenance, operation contrary to furnished instructions,
shipping or transit accidents, modification or repair by the user, abuse, misuse, neglect, accident, incorrect
power line voltage, fire, flood or other Acts of God, or normal wear and tear.
Warranty service must be performed by a qualified HVAC contractor. Soleus maintains a centralized
service network to provide parts and assist in resolving service problems if difficulties are encountered.
Soleus agrees to provide service information, sell repair parts and reimburse the dealer /serviceman for parts
in accordance with Soleus International’s Policies and Procedures.
SOLEUS INTERNATIONAL MAINTAINS THAT ALL WARRANTIES, INCLUDING IMPLIED
WARRANTY OR MERCHANTABILITY ARE LIMITED TO THE TERMS AND CONDITIONS
SPECIFIED ABOVE. SOLEUS INTERNATIONAL DISCLAIMS ANY LIBILITY FOR
CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT SHALL SOLEUS
INTERNATIONAL INC.’S LIABILITY EXCEED THE RETAIL VALUE OF THE AIR
CONDITIONER.
This warranty covers only new products purchased from our authorized dealers or retailers. It does not cover
internet sales, used, salvaged, or refurbished products.
FOR TECHNICAL SUPPORT AND WARRANTY SERVICE
Soleus International Inc.
Tel: 1-888-8 SOLEUS
Monday through Friday, 9:00 AM to 5:00 PM, PST
Email: [email protected]
Website:www.soleusair.com
- 24 -
Download from Www.Somanuals.com. All Manuals Search And Download.
|