Sherwood Scuba Diving Equipment SR 7206 User Manual

SERVICE INSTRUCTIONS  
DUAL OCTO  
SECOND STAGE REGULATOR  
SR 7206  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
The instructions set forth in this document are intended to guide the experienced scuba equipment repair  
technician through the standard service procedure for the Dual Octo second stage regulator.  
It is assumed that the technician possesses basic scuba equipment repair training and the skill necessary to  
perform the service. If you have not received regulator service training as an Authorized Sherwood Scuba  
Dealer do not attempt to perform the service described in this document. If you are uncertain as to whether  
you are qualified to perform this service contact your regional Sherwood Scuba Distributor for advice.  
GENERAL INSTRUCTIONS  
Special Notations  
WARNING: Indicatesapotentiallyhazardousconditionorsituationwhich,ifnotavoided,may  
result in serious injury or death.  
CAUTION: Indicatesapotentiallyhazardousconditionorsituationwhich,ifnotavoided,may  
result in minor or injury. It may also be used to alert against unsafe practices.  
NOTE:  
Indicates an important point or reminder.  
When to service  
Generally the Dual Octo should be inspected for service at least annually. If the regulator has been  
subjected to less than 100 hours of use it may just require a routine inspection not necessarily requiring the  
replacement of parts.  
If the regulator has been subjected to more than 100 hours of use or it has not received the benefit of  
careful post-dive cleaning and storage in a clean environment, the regulator should receive standard  
service. Standard service includes cleaning, inspection for damaged parts, replacement of seals and the  
valve seat, reassembly and adjustments.  
Dual Octo regulators that are subjected to extreme conditions such as daily use or infrequent cleaning may  
need service more frequently depending on inspection results.  
Sherwood Scuba offers a standard service kit (P/N 6000-9) that contains the parts that should be replaced  
at the standard service interval.  
Use only authorized parts and lubricants. Substitution of parts other than those available from  
Sherwood Scuba may cause the regulator not to perform as intended by the manufacturer and will void  
the warranty.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Working conditions  
Service should be performed in a well lighted, clean area with access to proper tools. Use of improper tools  
or techniques may cause permanent damage and void the warranty.  
Service Procedure  
The standard service procedure involves disassembly, inspection, cleaning, reassembly and adjustment of the  
regulator. As each step of the process is performed check the parts for damage or distortion. Replace parts  
that appear to have sustained damage.  
Cleaning can normally be performed by rinsing with the aid of mild detergent and a soft brush  
followed by a thorough rinsing with fresh water. Use of an ultrasonic cleaner and commercially available  
solutions can accelerate this process. Be certain to check with the supplier of the solution for compatibility with  
respiratory equipment. Thorough rinsing should always follow the use of any cleaning agents.  
O-rings should be lightly lubricated with Crysto-Lube MCG 111 before installation. Avoid the use of  
silicone spray or other lubricants containing hydrocarbons.  
Disassembly  
1. Pull back the hose protector (26) and inspect the hose for signs of cuts, cracks or other damage. A  
damaged hose should be replaced.  
2. Remove the Dual Octo assembly from the first stage regulator at the hose connection with a 9/16"  
(14 mm) wrench.  
3. Use a 3/4" (19 mm) wrench to support the Inlet Fitting (1) and 5/8"(16mm) wrench to separate the  
swivel end of the hose from the Inlet Fitting. Do not allow the Inlet fitting to rotate within the Housing (10),  
as this may cause damage to the Housing.  
4. Inspect the o-rings (18 and 20) at the both ends of the hose for signs of wear or damage. If these are  
damaged they should be replaced. Use only a nonmetallic or a soft brass instrument to remove the o-  
rings. Use of other tools and carelessness may cause damage to the sealing surfaces on the hose fittings  
requiring replacement of the entire hose. Sherwood does not recommend replacement of the o-ring at  
the swivel end of the hose if it does not show evidence of wear or damage.  
5. Remove the Mouthpiece (12) by cutting the Mouthpiece Strap (13) with side cutting pliers. Be careful  
not to cut or damage the Mouthpiece. Discard the strap and examine the Mouthpiece for cuts or tears.  
If there is damage it should be replaced.  
6. Remove the Cover Ring (24) by unthreading it from the Housing by hand. Tools should not be  
necessary and could cause damage to the Cover Ring. If it is difficult to remove, soak the entire  
regulator in warm water for a few minutes to loosen mineral deposits. Remove the Purge Cover (23)  
and Diaphragm Retainer (22).  
7. Gently remove the Diaphragm (21) from the Housing. Hold the Diaphragm up to a light source  
and gently stretch to search for tears or pin holes. If any are found replace the Diaphragm. If it is  
undamaged it may be reused.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Before further disassembly check the alignment of the Demand Lever (7) with regard to the Housing (10).  
The surface of the Demand Lever that contacts the Diaphragm should be parallel to the Housing within  
1/16 inches. Place a straight edge across the Housing to check the alignment of the Demand Lever.  
(Refer to Illustration 1). If the Demand Lever is above or below the edge of the Housing, it usually can be  
adjusted later as long as the surfaces are parallel. If the Demand Lever is distorted, it should be replaced.  
If the Lever Support (6) rotates within the Housing and causes the Demand Lever to deviate from a  
parallel position with regard to the Housing, check the Housing indexing feature for damage after  
the Lever Support is removed from the Housing. Damage of this type is generally caused by improper  
tightening of the LP Hose fitting without supporting the Inlet Fitting.  
1) Checking alignment of Demand Lever  
9. Use a wrench to remove the Inlet Fitting (1) from the Housing. Remove and discard the o-ring (2) using  
a nonmetallic or soft brass instrument to avoid damage to the sealing surfaces of the Inlet Fitting.  
NOTE: Deep scratches on metallic sealing surfaces may interfere with  
sealing and require replacement of the part.  
10. Gently remove the demand valve subassembly from the Housing as a complete subassembly. (Refer  
to Illustration 2) This subassembly consists of the Lever Support (6), Lever (7), Washer (8), Locknut (9),  
Spring (5), Poppet (4) and Seat (3). In most cases it is unnecessary to further disassemble the demand  
valve subassembly if it is free of corrosion or mineral deposits and the lever will move the poppet  
smoothly. If this is the case, then remove and discard the Seat (3). This may require the use of a straight  
pin or needle to pierce and extract the Seat. Be careful not to damage the metallic surfaces around and  
under the seat.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2) Demand Valve Subassembly  
11. If the subassembly shows salt or other mineral deposits that prevent the poppet from moving smoothly,  
it should be cleaned as an entire unit using an ultrasonic cleaner with a mild cleaning agent. If this fails  
to remove the deposits, the demand valve subassembly should be disassembled by unthreading the Lock  
Nut (9) from the Poppet (4). The disassembled parts may then be soaked in a mild solution of 50% white  
vinegar and scrubbed with a medium soft brush to remove deposits.  
12. Remove the mouthpiece Boss Retaining Ring (15) using snap ring pliers with 45 degree angled  
cylindrical tips. Use of this tool enables you to spread the Retaining Ring and slip it over the Mouthpiece  
Boss (11). Remove and discard the o-ring (14). Gently clean the o-ring groove on the Mouthpiece Boss  
and inspect the groove for cuts, deep scratches or other damage. Replace it if it is damaged.  
13. Remove the Exhaust Valve Cover (16) on each side of the Housing by grasping the cross bars on the  
cover by hand and gently unthreading. Gently remove each Exhaust Valve (17) by grasping the valve  
with the fingers and folding it in half. (Refer to Illustration 3). With the other hand grasp the stem of  
the valve and gently stretch it. This will allow you to pull the valve away from the Housing to remove it.  
Clean the surface of the housing where the Exhaust Valve seats. Inspect the seating surface under the  
valve for nicks, cuts or other damage that may prevent sealing of the exhaust valve. If these surfaces  
are damaged the Housing must be replaced. The valves are made of a durable material and should not  
require replacement unless they show signs of damage.  
3) Removal of Exhaust Valve  
14. Clean and rinse all parts in preparation for reassembly.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reassembly  
15. Install the Exhaust Valves using the same gentle stretching technique used for removal.  
16. Install each Exhaust Valve Cover using only your fingers to tighten. Use of tools may damage the  
Exhaust Valve Cover.  
17. If the demand valve subassembly was cleaned as a unit and not further disassembled install a  
new LP Seat (3). Do not attempt to use an old seat as the impression in the old seat may prevent  
adequate sealing.  
If the subassembly was disassembled, then place the Poppet (4) on a flat surface with the face the  
Poppet against the flat surface. Place the Spring (5) over the poppet stem and then place the Lever  
Support (6) over the Spring. Press down on the Lever Support taking care to match the square feature  
on the poppet stem with the matching square hole in the Lever Support. When the square features are  
aligned you will be able to compress the Spring until the Lever Support makes contact with the supporting  
flat surface. While maintaining the applied fore on the Lever Support, insert the Demand Lever as shown  
in Illustration 4. Use your fingers to hold the Demand Lever in place and add the stepped Washer (8) to  
the subassembly with the smallest diameter making contact with the Demand Lever.  
1
2
4) Compress the Spring against a flat surface and add the  
Demand Lever and Washer to the subassembly.  
Thread the Lock Nut (9) onto the Poppet just until the end of the poppet shaft starts to protrude from the  
end of the Lock Nut. The Lock Nut may be reused for several repeated services, but if it has been used  
to the extent that it rotates with very little resistance or will not stay in position it should be replaced.  
Install a new Seat into the Poppet.  
18. Inspect the crowned seating surface inside the Inlet Fitting for nicks, deep scratches or other signs of  
damage. Light corrosion may be removed with a pencil eraser. Do not attempt to polish with abrasive  
materials. If it is damaged it should be replaced. Install o-ring (2) onto the Inlet Fitting.  
19. Insert the demand valve subassembly into position inside the Housing taking care to align the indexing  
notch with the block feature in the Housing. If these parts cannot be aligned, check to be certain the  
Demand Lever is not installed upside down.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
20. Hold the demand valve subassembly in place and install the Inlet Fitting. Hand tighten (approximately  
40 in lbs). As the Inlet Fitting is installed the Demand Lever position will change and it will be loosely  
retained until the final adjustment is made.  
21. Use the nut driver to tighten the Lock Nut until the Demand Lever rises to be level with the top of  
the Housing.  
22. Install the LP Hose (19) onto the Inlet Fitting. Be certain to secure the Inlet Fitting with a wrench as the  
hose fitting is tightened (40 in-lbs).  
CAUTION – Rotation of the Inlet Fitting within the Housing will damage the  
indexing feature and may cause the Demand Lever to misalign. This could  
compromise regulator performance and will require replacement of the Housing.  
23. Attach the LP Hose to the first stage regulator and torque to 40 in lbs.  
24. The Dual Octo is designed to be compatible with regulators that operate with an intermediate pressure  
ranging from 120 to 150 PSI. If the first stage is not operating within these pressures, the Dual Octo  
may not perform properly. If necessary, service the first stage regulator so that it operates within these  
pressures or match the Dual Octo to a first stage that does operate within the prescribed limits.  
25. Apply pressure to the regulator assembly and tighten the Lock Nut until a very slight leak is presented.  
Loosen the Lock Nut slowly until the leakage stops. Continue loosening approximately 1/8 turn. The  
Demand Lever should be aligned with or slightly below the surface of the top of the Housing and should  
allow slight movement of the lever without opening the valve. If the correct alignment is not present  
continue loosening the Lock Nut until alignment is achieved, but do not loosen the Lock Nut more than  
1/4 turn past the point where leakage is stopped. If alignment cannot be achieved it is likely the Demand  
Lever is distorted and must be replaced.  
26. Install o-ring (14) on to the Mouthpiece Boss.  
27. Install the Mouthpiece Boss into the Housing noting the desired orientation of the Mouthpiece. There  
are two positions available and the selection should match the users choice. Use snap ring pliers to  
spread the Retaining Ring (15) and position it over the groove on the Mouthpiece Boss. After the  
Retaining Ring is released, check to verify that it contained in the groove. Pull on the Mouthpiece Boss to  
check retention.  
WARNING – Failure to properly secure the Mouthpiece Boss to the Housing may  
result in separation during a dive. If this were to occur the diver may be exposed  
to inhalation of water causing a potentially hazardous condition requiring an  
appropriate emergency response to avoid serious injury or death.  
28. Install the Mouthpiece (12) and secure with the Mouthpiece Strap (13).  
29. Install the Diaphragm, Retainer and Purge Cover with the Sherwood logo aligned parallel with the axis  
of the Inlet Fitting.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
30. Install the Cover Ring and hand tighten until there is no gap between the Housing and the  
Purge Cover.  
Final Check  
31. With pressure applied to the regulator assembly immerse the entire regulator to check for air leaks.  
Air leaks are most commonly caused by damaged or contaminated o-rings. Repair or replace  
as necessary.  
32. Release the pressure from the regulator assembly keeping the assembly mounted to the closed cylinder  
valve. Apply a vacuum to the Dual Octo until movement of the diaphragm is detected. Stop applying  
the vacuum and observe whether air is leaking back into the Housing. Sources of leakage must be  
corrected and are usually traceable to a damaged or improperly installed a) Diaphragm,  
b) Mouthpiece or Mouthpiece Boss or c) Exhaust Valves.  
WARNING – If the sources of leakage into the Housing are not resolved the user may  
be exposed to entrance of water into the regulator while diving. If this is not treated  
with an appropriate response the user may become stressed and subject to risk of  
serious injury or death.  
33. Pressurize the regulator and depress the purge to verify that a strong flow of air is available. If the flow is  
slight, the position of the Demand Lever is probably the cause and a correction should be made. Repeat  
Step 25 or replace Demand Lever if necessary.  
34. If a regulator test bench is available check to verify that the cracking pressure is between 0.75 and  
1.5 inches of water. If no bench is available, cracking pressure can be verified by slowly immersing  
the pressurized Dual Octo with the mouthpiece in an upward position. The regulator should begin to  
deliver air when the Diaphragm is 0.75 to 1.5 inches below the surface of the water. Be certain to  
allow the regulator to completely dry before storing in a closed container.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY INFORMATION  
The Dual Octo Regulator is warranted against manufacturing defects for a period of two years from the  
date of purchase from an Authorized Sherwood Dealer. Warranty extends only to the original purchaser  
of the product and is not transferable. Warranty services requires proof of purchase. Keep your sales  
receipt to present as proof of valid purchase. Warranty is limited to repair or replacement at the discretion  
of Sherwood Scuba.  
In addition, as an original owner of the Dual Octo Regulator you may be eligible to receive two sets of stan-  
dard service parts provided that service is performed by an Authorized Sherwood Dealer. Service labor is  
not included and is the responsibility of the product owner. The Hose Protector on the Dual Octo has two  
removable plastic rings. Each ring may be redeemed for a standard service parts kit (P/N 6000-9) at the  
time service is performed. Please see your Authorized Sherwood Dealer for details.  
PETER SKOP INDUSTRIES  
6161 Atlantic Blvd.  
Norcross · Georgia 30071  
Toll Free: 800-774-4447  
TL: 770-449-4141  
Toll Free FX: 800-849-4774  
FX: 770-242-0683  
DIVERSCO  
495 Conestoga Blvd.  
Cambridge · Ontario N1R 7P4  
Toll Free: 800-650-0061  
TL: 519-740-1210  
Toll Free FX: 877-264-3920  
FX: 519-740-9051  
CRAMER DECKER INDUSTRIES  
1641 E. St. Andrew Place  
Santa Ana · California 92705  
Toll Free: 800-347-9766  
TL: 714-566-3820  
: 714-566-3839  
Download from Www.Somanuals.com. All Manuals Search And Download.  
24  
25  
23  
22  
21  
10  
20  
18  
19  
13  
15  
17  
14  
16  
12  
11  
9
8
7
5
4
6
3
2
1
Item Qty. Part No.  
Description  
Inlet Fitting  
O-ring  
LP Seat  
Poppet  
Item Qty. Part No.  
Description  
O-ring  
Retaining  
Cover, Exhaust  
Valve, Exhaust  
O-ring  
Hose, Octo, LP  
O-ring  
Diaphragm  
Retainer  
Purge Cover  
Cover Ring  
Warranty Ring  
Hose Protector  
1
2
3
4
1
1
1
1
1-7206-7  
G015B  
7206-9BN  
9-7206-18  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
1
1
2
2
1
1
1
1
1
1
1
2
1
G020-B  
7206-68  
7206-8  
7206-15  
G011B  
7206-50-36  
G010A  
7206-4A  
7206-6  
7206-23  
7206-24  
SWC01  
7206-27  
5
6
7
8
9
10  
11  
12  
13  
1
1
1
1
1
1
1
1
1
19-7206-29  
9-7206-9  
7206-10  
7206-73  
7206-71  
7206-5  
7206-2  
7206-3  
7206-1  
Spring  
Lever Support  
Lever  
Washer  
Locknut  
Housing  
Boss, Mouthpiece  
Mouthpiece  
Strap, Mouthpiece  
WARNING  
Use only Sherwood Scuba parts! Use of other manufacturer’s parts will void all warranties  
and could result in air delivery failure, causing serious personal injury or death.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Servis Rhino Compact Loader 2407TL User Manual
Shoprider Wheelchair UL8W36 User Manual
SIIG Computer Keyboard 04 0585C User Manual
Sony Portable CD Player D E330 User Manual
Sony Portable Speaker Walkman CD User Manual
Sony Speaker STR AV1000 User Manual
Sony Webcam VGN BZ User Manual
Summit Freezer AL 650 User Manual
Swisher Trimmer E4 S3000 User Manual
Sylvania TV VCR Combo 6719DD User Manual