R
FU-W53J
Plasmacluster is a trademark of
Sharp Corporation.
AIR PURIFIER
OPERATION MANUAL
Free standing type
Download from Www.Somanuals.com. All Manuals Search And Download.
ENGLISH
FEATURES
CONTENTS
"Plasmacluster" technology
.....
IMPORTANT SAFETY INSTRUCTIONS
E-2
Plasmacluster technology uses plas-
ma discharge to produce and release
the same positive and negative ions
as those found in nature ("Plasma-
cluster ions").
• WARNING ....................................................
• CAUTIONS CONCERNING OPERATION ...
• INSTALLATION GUIDELINES......................
• FILTER GUIDELINES ..................................
E-2
E-3
E-3
E-3
This is a unique air cleaning technol-
ogy of the SHARP CORPORATION
for breaking down and inactivating
such potential allergens as the faecal
matter or corpses of aerial mites*1,
viruses*2 and mould and bacteria*3
suspended in the air, and has been
substantiated by third-party organisa-
tions both in Japan and overseas.
When there is a high density of Plas-
macluster ions in the air, the smell of
cigarette smoke trapped in curtains
or sofas is removed in about 80 min-
utes*4, and when clothing is hung in
a place exposed to the direct air ex-
pelled from the unit generating Plas-
macluster ions, the smell of sweat is
reduced to a virtually imperceptible
level in one night (about 6 hours).
...............................................
PART NAMES
E-4
• MAIN UNIT DISPLAY ...................................
• ILLUSTRATIVE DIAGRAM...........................
• BACK............................................................
• INCLUDED...................................................
E-4
E-4
E-5
E-5
............................................
PREPARATION
E-6
E-6
• FILTER INSTALLATION ...............................
.................................................
OPERATION
E-8
E-8
• MAIN UNIT OPERATION .............................
...................
CARE AND MAINTENANCE
E-10
• FILTER RESET INDICATOR LIGHT ..........
• MAIN UNIT.................................................
• FILTER .......................................................
• SENSORS..................................................
E-10
E-10
E-10
E-10
E-11
•
WASHABLE ACTIVE CARBON FILTER CARE.....
• FILTER REPLACEMENT
GUIDELINES..............................................
E-12
E-13
*1 Graduate School of Advanced Sci-
ences of Matter, Hiroshima University,
Japan
..............................
TROUBLESHOOTING
Measurement of action on the potential
allergens of aerial mites (in the area of
13m²).
......................................
SPECIFICATIONS
E-14
*2 Retroscreen Virology, Ltd., London, UK
Measurement of ratio of viruses re-
moval from the air in a 1m³ box
*3 Ishikawa Health Service Association,
Japan
Measurement of aerial mould and bac-
teria in a 13m² lab using an air sampler.
*4 Japan Spinners Inspecting Foundation,
Japan
Evaluation of deodorising effect on
odour-imbued fragments of cloth
Thank you for purchasing the SHARP Air Puri-
fier. Please read this manual carefully for the
correct usage information. Before using this
product, be sure to read the section: “Important
Safety Instructions.”
After reading this manual, retain it in a conven-
ient location for future reference.
E-1
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed, including the
following:
- To reduce the risk of electrical shock, fire or injury to persons:
WARNING
• Read all instructions before using the unit.
• Use only a 220-240 volt outlet.
• Do not use the unit if the power cord or plug is damaged or the connection to the wall outlet
is loosened.
• Periodically remove dust from the power plug.
• Do not insert fingers or foreign objects into the air intake or outlet.
• When removing the power plug, always hold the plug and never pull the cord.
Electrical shock and/or fire from short circuit may occur as a result.
• Do not remove the plug when your hands are wet.
• Do not use this unit near gas appliances or fireplaces.
• Remove the power plug from the wall outlet before cleaning the unit and when not using the
unit.
Electrical shock from bad insulation and/or fire from short circuit may occur as a result.
• If the power cord is damaged, it must be replaced by the manufacturer, its service agent,
Sharp Approved Service Centre or similarly qualified person in order to avoid a hazard.
• Do not operate when using aerosol insecticides or in rooms where there is oily residue, incense,
sparks from lit cigarettes, chemical fumes in the air or in very high humidity condition, such as a
bathroom.
• Be cautious when cleaning the unit. Strong corrosive cleansers may damage the exterior.
• Only Sharp Approved Service Centres should service this air purifier. Contact your nearest Ap-
proved Service Centre for any problems, adjustments, or repairs.
• This appliance is not intended for use by persons (including children) with reduced physical, sen-
sory or mental capabilities, or lack of experience and knowledge, unless they have been given su-
pervision or instruction concerning use of the appliance by a person responsible for their safety.
• Children should be supervised to ensure they do not play with the appliance.
- Radio or TV Interference
NOTE
If this air purifier should cause interference to radio or television reception, try to correct the interfer-
ence by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation distance between the unit and radio/TV receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is con-
nected.
• Consult the dealer or an experienced radio/TV technician for help.
E-2
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
CAUTIONS CONCERNING OPERATION
• Do not block the air intake and/or outlet.
• Do not use the unit near or on hot objects, such as stoves or heaters or where it may come into
contact with steam.
• Do not lay the unit down when turned on.
• Always hold the handle on the back of the unit when moving it.
Holding the front panel when carrying may cause it to detach, thus dropping the unit and resulting
in personal injury.
• Do not operate the unit without the filter.
• Do not wash and reuse HEPA filter .
It not only does not improve filter performance, it may cause electric shock or malfunction.
• Clean the exterior with a soft cloth only.
Otherwise the unit surface may get damaged or cracked.
In addition, the sensors may malfunction as a result.
INSTALLATION GUIDELINES
• During operation, please place the unit at least 2 m away from equipment which may be
subject to electrical waves such as televisions, radios or wave clocks.
• Avoid a location where the sensor is exposed to direct wind.
The unit may not operate properly.
• Avoid locations where curtains, etc., come into contact with the air intake or outlet.
Curtains, etc., may become dirty or a unitl malfunction may occur.
• Avoid locations where the unit is exposed to condensation, due to drastic temperature
changes.
(Use under appropriate conditions between 0 and 35˚C in the room.)
• Place on a stable surface with sufficient air circulation.
When placing the unit on a thick carpeted area, it may cause the unit to vibrate slightly.
• Do not install when there is a possibility of soot, such as in a kitchen, etc.
The unit surface may crack or the sensor may malfunction as a result.
• Leave about 60cm of space from the wall.
The wall behind the air outlet may become dirty as time passes. When using the unit for an ex-
tended period of time in the same location, use a vinyl sheet, etc., to prevent the wall from becom-
ing dirty. In addition, periodically clean the wall.
FILTER GUIDELINES
• Follow the instructions in this manual for correct care and maintenance of the filters.
Use only filters designed for this product.
E-3
Download from Www.Somanuals.com. All Manuals Search And Download.
PART NAMES
MAIN UNIT DISPLAY
Fan Speed Indicator Lights
Filter Reset Indicator Light
Plasmacluster
ON/OFF Indicator Light
Plasmacluster Ion ON/OFF
Button
Fan Speed Button
ION SHOWER Indicator Light
ION SHOWER Mode Button
ILLUSTRATIVE DIAGRAM
Date Label
Odour Sensor
Main Unit
HEPA Filter
Washable Active
Carbon Filter
Filter Support
Front Panel
E-4
Download from Www.Somanuals.com. All Manuals Search And Download.
Plasmacluster Indicator Light(Blue)
Blue light : Plasmacluster ON
Light off : Plasmacluster OFF
CLEAN - SIGN Light
The colour changes according to
the air condition.
Clean
Green
Slightly Impure Very Impure
Yellow Red
ABOUT THE CLEAN-SIGN
•The condition of the CLEAN-SIGN depends on the room air condition detect-
ed by the Dust and Odour Sensors when the plug is inserted into the wall outlet.
•It is possible to have a green CLEAN-SIGN with impurities in the air at the time
that the air purifier was just introduced to the room environment. After a while,
however, the base impurity rate will be adjusted to detect room air condition
correctly.
POWER ON/OFF
Button
Light Control Button
BACK
INCLUDED
Air Outlet
Handle
• Operation manual
Dust Sensor
Rating Label
Air Inlet
Power Cord
Plug
(Shape of plug depends on country).
E-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Be sure to remove the power plug from the wall outlet.
PREPARATION
FILTER INSTALLATION
To maintain the quality of the filters, they are installed in the main unit and packed in
plastic bags. Be sure to remove the filters from the plastic bags before using the unit.
Remove the filters
Front Panel
1
Remove the Front Panel.
Pull the Front Panel on the
lower sides, and lift up.
1
Remove the Filter Support.
Push in the hooks on top, then pull the Filter Support.
2
Filter Support
Remove the washable Active Carbon Filter (Black) and
HEPA Filter (White) from the plastic bags.
3
Active Carbon Filter
HEPA Filter
E-6
Download from Www.Somanuals.com. All Manuals Search And Download.
Tab
Install the filters
2
Place the HEPA Filter into the
main unit.
1
Please make sure that the HEPA
Filter(blue) and the tab is placed
in proper direction.
(blue)
HEPA Filter
Do not install the filter backwards or the
unit will not operate properly.
Insert two bottom tabs (left and right)
of the Filter Support into the small
holes in the unit, and slide the Active
Carbon Filter between the HEPA Filter
and the Filter Support.
2
Active Carbon Filter
Filter Support
Bottom tabs
Gently push in the upper tabs (left and
right) to lock in place.
3
4
5
Upper tabs
Fill in the usage start date on the Date
Label.
Use the date as a guide for the Filter Replace-
Date Label
ment schedule.
Replace the Front Panel.
Place the Front Panel from the top first, then
mount the hooks at the bottom.
Front Panel
E-7
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION
MAIN UNIT OPERATION
Power ON/OFF Button
FAN Speed Indicator Lights
FAN SPEED Button
Plasmacluster
ON/OFF Button
• Used to start operation (short beep) and
stop operation (long beep)
• Plasmacluster Indicator Light and Fan
Speed Indicator Light turn on/off.
• Unless the power cord is unplugged, the op-
eration will start in the previous mode.
• When stopping the operation in ION SHOW-
ER mode, the unit will return to the prior
ION SHOWER mode.
FAN SPEED Button
• The operation mode can be switched as below.
AUTO operation
SILENT operation
The fan speed is automatically switched
(MEDIUM, LOW) depending on the
amount of impurities in the air. The sen-
sors detect the impurities for efficient
air purification.
The unit will operate quietly
using minimal air intake.
MEDIUM operation
The unit will operate at a fan
speed of MEDIUM.
POLLEN mode operation
The unit will operate at HIGH* fan
speed for 10 minutes, then will alter-
nate between MEDIUM and HIGH* for
20 minutes.
MAX operation
The unit will operate at a fan
speed of MAX.
10 minutes: HIGH fan speed
20 minutes: MEDIUM fan speed
20 minutes: HIGH fan speed
* HIGH fan speed is an inter-
mediate speed between ME-
DIUM and MAX.
*LOW fan speed is an interme-
diate speed between SILENT
and MEDIUM.
ION SHOWER Mode Button
When the ION SHOWER Mode button is pushed, the ION SHOWER
operation will be activated. (Direct start is available even when the unit
is not turned on.)
By continuously discharging a strong airflow for 15 minutes the unit effectively
removes airborne dust, pollen, mould and allergens from the air as they are
drawn through the filter system.
•When the operation finishes, the unit will return to the prior operation.
Download from Www.Somanuals.cEom-.8All Manuals Search And Download.
Plasmacluster Indicator Light
CLEAN - SIGN Light
POWER ON/OFF Button
LIGHT CONTROL Button
ION SHOWER Mode Button
Plasmacluster ON/OFF Button
Press the Plasmacluster ON/OFF Button to turn Plasmacluster Ion
Mode ON and OFF.
When Plasmacluster is ON, both the Indicator Light and Plasmaclus-
ter Indicator will turn on.
LIGHTS CONTROL Button
Turns the Plasmacluster Indicator
Light and CLEAN-SIGN Light brighter,
darker or off.
Refer to the diagram on the right to
The lights are brighter.
The lights are darker.
The lights turn off.
「 」
「 」
「 」
select the desired brightness of the
Plasmacluster Indicator Light and
CLEAN-SIGN Light.
CAUTION
The lights on the front monitor are always brighter when starting.
ADJUSTMENT OF SENSOR DETECTION SENSITIVITY
Set to “low” if CLEAN-SIGN Light is constantly red to reduce sensitivity, and set to
“high” if CLEAN-SIGN Light is constantly green to increase sensitivity.
With the unit OFF, press the Fan Speed Button for 3 seconds.
The Fan Speed Indicator Lights will display the currently set sensor sensitivity level. The
factory setting is Standard, indicated by the MED light.
1
Fan Speed
Indicator Light
Sensor Detection
sensitivity
Press the Fan Speed Button to set
the desired sensor sensitivity.
Refer to the diagram on the right to select the
desired sensor sensitivity level.
2
High
Standard
Low
Press the Power ON/OFF Button.
Note that if the Power ON/OFF Button is not pushed within 8 seconds of adjusting sensor sensitivity, the set-
ting will be saved automatically. The sensor sensitivity setting will be saved even if the unit is unplugged
3
.
E-9
Download from Www.Somanuals.com. All Manuals Search And Download.
CARE AND MAINTENANCE
To maintain optimum performance of this air purifier, please clean the unit including the sen-
sor and filters periodically. When cleaning the unit, be sure to unplug the power cord, and nev-
er handle the plug with wet hands. Electrical shock and/or bodily injury may occur as a result.
FILTER RESET INDICATOR LIGHT
The Filter RESET Indicator Light will illuminate as a reminder to perform mainte-
nance of the Filters and Sensors.The Indicator Light will turn on after approximately
720 hours of use.
After performing maintenance, reset the Filter Reset Indicator. Plug the unit in, turn
power ON, and press the Plasmacluster Ion ON/OFF Button for 3 seconds. The Fil-
ter Indicator Light will go off. Even if the Filter Indicator Light is already off, the Plas-
macluster Ion ON/OFF Button should be pressed to reset the maintenance timer.
MAIN UNIT
Care Cycle 1 month
To prevent dirt or stains on the main unit, clean as often as necessary. If stains are allowed to
remain, they may become hard to clean.
Wipe with a dry, soft cloth
For stubborn stains or dirt, use a soft cloth dampened with warm water.
Do not use volatile fluids
Benzine, paint thinner, polishing powder, etc., may damage the surface.
Do not use detergents
Detergent ingredients may damage the unit.
Keep the unit away from water
FILTER
Care Cycle 2 months
Washable Active
Carbon Filter
Clean the top surface of the Washable Active
Carbon Filter lightly with a vacuum cleaner.
(DUST SENSOR, ODOUR SENSOR)
SENSORS
Care Cycle 2 months
SENSOR FILTER CARE
Remove dust from the surface of the hole of the
Detach the sensor filter and
sensors using a vacuum cleaner.
tap it lightly with your hand to
remove the dust.
Hole of Odour Sensor
If it is very dirty, wash it with
water and then allow it to dry
thoroughly.
Sensor Cover
Sensor Cover
Sensor Filter
It does not have a
front and a back.
Hole of Dust Sensor
E-10
Download from Www.Somanuals.com. All Manuals Search And Download.
WASHABLE ACTIVE CARBON FILTER CARE
Care Cycle 2 months
HAND WASH ONLY!
DO NOT TUMBLE DRY!
HEPA Filter
Washable Active
Carbon Filter
Rinse dirt from the WASHABLE ACTIVE CARBON
FILTER under lukewarm water.
Remove dust on the washable active carbon filter before washing.
1
CAUTION
•When washing the filter for the first time, the rinse water may be
brown. This does not affect deodorisation performance.
•Avoid bending or folding the filter when washing.
Drip dry filter to remove excess water.
2
3
Dry filter completely in a well ventilated area. If
possible, dry outdoors.
Dry filter in a sideways position to avoid warping of the filter.
The filter takes about 6 hours to dry out.
CAUTION
• Avoid drying filter outdoors during inclement weather (e.g. rain or cold
temperatures).
• Do not allow filter to freeze.
• If filter is dried indoors, take precautions, such as placing towels, etc
under the filter to prevent water damage to the floor.
Replace the filter in unit. (See E-6).
Dry filter completely before replacing to prevent odours.
Do not operate unit without all filters properly installed.
4
E-11
Download from Www.Somanuals.com. All Manuals Search And Download.
CARE AND MAINTENANCE
FILTER REPLACEMENT GUIDELINES
The replacement period differs depending on the room environment, the usage hours
and location of the Air Purifier.
If dust or odour persist, replace the filters.
(Refer to “Please read before operating your new Air Purifier”)
HEPA Filter / Washable Active Carbon Filter
Up to 5 years after opening
Guide for filter replacement timing
• Filter life can be greatly reduced in a poor environment.
The presence of cigarette smoke, pet dander and other concentrations of airborne particles
will cause filters to become clogged in less time. Please check filters regularly and replace
as needed.
Replacement Filters
Model • HEPA Filter : 1 unit
FZ-W53SFJ • Washable Active Carbon Filter : 1 unit
REPLACING THE FILTERS
1. See page E-6,7 for directions on how to install the filters when replacing.
2. Fill in the usage start date of the filters on the Date Label.
Disposal of Filters
Please dispose of replaced filters according to the local disposal laws and regulations.
HEPA Filter Materials:
• Filter: Polypropylene • Frame: Polyester
Active Carbon Filter Materials:
• Deodoriser: Activated charcoal • Net: Polypropylene 60%, Polyester 40%
E-12
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
Before calling for repair, please review the list below, since the problem may not be a unit malfunction.
SYMPTOM
REMEDY (not a malfunction)
• Clean or replace the filters if they appear to be heavily soiled.
(Refer to E-11, E-12)
Odours and smoke are not
removed.
• The air could be impure at the time the unit was plugged in. (Refer
to E-5) Pull out the plug from the electrical outlet, and insert the
The CLEAN-SIGN Light shows
green even when the air is im-
pure.
plug one minute later
.
• The sensitivity of the sensors becomes unstable when the
opening of the odour sensor or dust sensor is dirty or is clogged.
Clean the dust around the sensor opening using a vacuum
cleaner. (Refer to E-10)
The CLEAN-SIGN Light shows
yellow or red even when the air
is clean.
• Clicking or ticking sounds may be audible when the unit is gen-
erating ions.
A clicking or ticking sound is
heard from the unit.
• Check to see if the filters are heavily soiled.
Replace the filters.
• Plasmacluster Air Purifiers emit small traces of ozone which
may produce an odour. These ozone emissions are well below
safety levels .
The discharged air has an aroma
or odour.
• Is the unit installed in a location that is difficult for the sensor to
detect cigarette smoke?
• Are the dust or odour sensor openings blocked or clogged?
(In this case, clean the openings.) (Refer to E-10)
The unit does not operate when
cigarette smoke is in the air.
• Check to see if the Lights OFF Mode is selected. If so, then
press the Light Control Button to activate the indicator lights.
(Refer to E-9)
The Plasmacluster Indicator
Light or the CLEAN-SIGN Light
will not activate.
If you still require service, contact your SHARP approved service centre.
SHARP approved service centre locations can be found in the support area of our website:
ERROR DISPLAY
LAMP INDICATION
REMEDY
Fan motor disconnected or abnormal.
Operation stops.
• Pressing the POWER ON/OFF button will reset the error dis-
play, but if error occurs again, contact the shop where you
purchased the unit.
The “Silent” Fan Speed Indica-
tor Light blinks.
E-13
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS
Model
FU-W53J
220-240V 50Hz
MED
Power supply
SILENT
3.5W(3.2W) *1
36m3/hour
MAX
42W
Fan Speed Adjustment
Fan
Speed
Operation
15W
Rated Power
204m3/hour
~41m2 *2
~20m2 *3
2.0m
318m3/hour
Fan Speed
Recommended Room Size
High density Plasmacluster ion applicable floor surface
Cord Length
Dimensions
Weight
338mm(W)x205mm(D)x620mm(H)
6.1kg
Numbers in parentheses indicate the power consumption when the Plasmacluster indicator light and the
CLEAN-SIGN light are off.
*1
*2
The applicable floor surface area is appropriate for operating the unit at maximum fan speed.
•Applicable floor surface area indicates the space where a certain amount of dust particles can be
removed in 30 minutes.(JEM1467)
*3
Size of a room in which approximately 7000 ions can be measured per cubic centimeter in the
center of the room (at a height of approximately 1.2 meters from the floor) when the product is
placed next to a window and run at the MAX operation position.
The class of the HEPA filter by EN1822 is H10.
In order to operate the electrical circuits while the power plug is inserted in the
wall outlet, this product consumes about 0.8W of standby power.
Standby Power
For energy conservation, unplug the power cord when the unit is not in use.
Download from Www.Somanuals.Eco-m1. A4ll Manuals Search And Download.
Memo
Download from Www.Somanuals.com. All Manuals Search And Download.
Memo
Download from Www.Somanuals.com. All Manuals Search And Download.
Memo
Download from Www.Somanuals.com. All Manuals Search And Download.
SHARP CORPORATION OF AUSTRALIA PTY.LTD.
A. B. N. 40 003 039 405
1 HUNTINGWOOD DRIVE, HUNTINGWOOD, N.S.W. 2148
P.O.BOX 6827, BLACKTOWN. N.S.W. 2148
SHARP CORPORATION OF NEW ZEALAND LIMITED
59 HUGO JOHNSTON DRIVE PENROSE, AUCKLAND
Printed in China
TINS-A352KKRZ 09K
1
CN
Download from Www.Somanuals.com. All Manuals Search And Download.
|