ENGLISH  
FEATURES  
Cluster Ion Control  
The unit controls the ratio of minus cluster  
ions and plus cluster ions depending on  
the condition of the room.  
CONTENTS  
SAFETY PRECAUTIONS ........................ E-2  
• Clean mode  
• CAUTIONS CONCERNING THE USAGE  
OF THIS PRODUCT ....................................E-3  
• CAUTIONS WHEN MOUNTING THIS  
PRODUCT TO A WALL ................................E-3  
Approximately the same amount of plus  
and minus cluster ions are discharged.  
This mode is effective for reducing floating  
mold and household odors in the air.  
• CAUTIONS CONCERNING  
• Refresh mode  
THE INSTALLATION ....................................E-3  
It is said that plenty of minus ions exist in  
places such as waterfalls or forests in  
natural environment. In this operation  
mode, minus ions will be released in an  
increased rate, in order to bring the room  
air close to this condition.  
NAMES OF PARTS ................................. E-4  
• ACCESSORIES ...........................................E-5  
INSTALLATION ....................................... E-6  
• AUTO cluster ion mode  
WHEN USING THE UNIT ON A TABLETOP .. E-6  
The unit will switch between the Clean  
mode and Refresh mode automatically  
depending on the amount of pollution in  
the air detected by dust and odor sensor.  
• WHEN USING THE UNIT  
WITH A MOUNTED WALL ...........................E-7  
PREPARATION........................................ E-8  
• INSTALLING THE FILTERS .........................E-8  
• INSERTING BATTERIES  
IN THE REMOTE CONTROL ......................E-8  
HEPA Filter  
• High-efficiency dust collection  
• USING THE REMOTE CONTROL...............E-9  
Stamina-power carbon  
Powerful deodorization by large particles  
of columnar charcoal.  
OPERATION .......................................... E-10  
• MAIN UNIT OPERATION .......................... E-10  
• REMOTE CONTROL OPERATION ...........E-11  
CARE AND MAINTENANCE................. E-12  
FOR UNDERSTANDING  
THE PRODUCT  
• MAIN UNIT................................................ E-12  
• FILTERS.................................................... E-12  
• GUIDE FOR LIFE OF FILTERS ................ E-13  
Some of the odor ingredients  
adsorbed by the filters become sepa-  
rated and are discharged through the  
exhaust port as odor.  
TROUBLE SHOOTING.......................... E-14  
Depending on the usage environment,  
this odor may become strong in  
several months and the exhaust port  
may smell.  
SPECIFICATIONS ................................. E-14  
In this case, purchase the exchange  
filter FZ-40SEF of the option goods,  
and replace the filters.  
Thank you for purchasing the SHARP FU-40SE.  
Please read the instruction manual carefully for  
the correct usage. Before using this product,  
be sure to read “Safety precautions.”  
After reading this manual, retain it in a conven-  
ient location for future reference.  
This product is for household use only.  
This equipment complies with the  
requirements of Directives 89/  
336/EEC and 73/23/EEC as  
amended by 93/68/EEC.  
E-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY PRECAUTIONS  
• Do not use the unit if the power cord or plug is damaged or the connection to the wall  
outlet is loose.  
Electrical shock, short circuit and/or fire may occur as a result.  
• Do not damage, break, coat, forcefully bend, pull, twist, bundle, pinch or place heavy  
objects on the power cord.  
If the power cord is damaged, fire and/or electrical shock may occur as a result.  
• Use AC 220~240V only.  
Fire and/or electrical shock may occur as a result.  
• Do not modify. Repair and disassembly of this product are to be performed by authorized  
service personnel only.  
Fire, electrical shock and/or bodily injury may occur as a result.  
For repair, contact your dealer of purchase or the nearest Sharp Service Center.  
• Periodically remove dust from the power plug  
Accumulated dust on the power plug may cause bad insulation from humidity, etc.  
Fire and/or electrical shock may occur as a result.  
• When cleaning the unit, be sure to remove the power plug from the wall outlet.  
In addition, never handle the power plug with wet hands.  
Electrical shock and/or bodily injury may occur as a result.  
• Do not use the unit where there are oil ingredients such as cooking oil, etc., in the air.  
Cracking of the unit surface may occur as a result.  
• Do not wipe the unit with benzene or paint thinner. Also, do not spray insecticides on the  
unit.  
Cracking, electrical shock and/or fire may occur as a result.  
• Do not operate the unit when using indoor smoke-generating insecticides.  
Chemical ingredients may accumulate within the unit and then discharge from the exhaust port  
when the unit operates. Discharge of such chemicals may be unhealthy to your body.  
• Do not allow the unit to intake flammable gases, sparks from lit cigarettes, incense, etc.  
The unit may ignite as a result.  
• Do not use the unit where it is humid, such as in a bathroom, etc., or where the unit may  
get wet.  
Electrical shock and/or malfunction may occur as a result.  
• Do not insert fingers or foreign objects into the intake or exhaust ports.  
Electrical shock and/or malfunction may occur as a result.  
• When mounting to a wall, select a sturdy wall or studding.  
The unit may fall as result.  
• When removing the power plug, always hold the plug and never pull the cord.  
Electrical shock and/or fire from short circuit may occur as a result.  
• Ventilate when using the unit along with a heating appliance.  
Carbon monoxide poisoning may occur as a result.  
• Remove the power plug when not using the unit.  
Electrical shock from bad insulation and/or fire from short circuit may occur as a result.  
• If the supply cord is damaged, it must be replaced by the manufacturer or its service agent  
or similarly qualified person in order to avoid a hazard.  
• The batteries must be removed from the appliance before it is scrapped and that they are  
disposed of safely.  
E-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUTIONS CONCERNING THE USAGE OF THIS PRODUCT  
• Do not block the intake and exhaust ports.  
• Do not use the unit near or on hot objects, such as a stove, etc. Also, do not use the unit where it may  
come into contact with steam.  
• Do not use the unit on its side.  
Deformation, malfunction and/or overheating of the motor may occur as a result.  
• Do not install when there is generation of lampblack, such as in a kitchen, etc.  
• Do not use detergent when cleaning the unit.  
The unit surface may become damaged or cracked.  
In addition, the sensors may malfunction as a result.  
• When transporting the unit, always hold the handle on the back of the unit.  
Holding the front panel when carrying may cause it to detach, thus dropping the unit and resulting in  
bodily injury.  
CAUTIONS WHEN MOUNTING THIS PRODUCT TO A WALL  
• A wall side to install is to choose the place to have the strength done firmly.  
• Never mount the unit to a thin wall or plasterboard of insufficient strength.The unit may drop  
as a result.  
• When mounting the unit to a wall, remove the front panel and hold the main unit.  
Holding the front panel may cause it to become detached, thus dropping the unit and resulting in  
bodily injury.  
• Do not install when there is generation of lampblack, such as in a kitchen, etc.  
The unit surface may crack or the sensors may malfunction as a result.  
CAUTIONS CONCERNING THE INSTALLATION  
DO NOT USE THE REMOTE CONTROL IN THE FOLLOWING LOCATIONS  
• Location where there are inverter lighting equipment or electronic spontaneous lighting equip-  
ment  
The remote control may become inoperative. In this case, move away from such lighting equipment  
or change direction.  
• Location exposed to direct sunlight  
The unit may not received signals from the remote control  
The unit may not respond to the signals of the remote control if the ends of fluorescent lighting  
become black or lights flicker due the depletion of service life;however, this is not a malfunction of the  
remote control or the main unit. In this case, replace the lighting with new fluorescent tubes.  
TAKE CAUTION TO THE FOLLOWING DURING INSTALLATION  
• Leave at least 2m of space from televisions and radios  
Electrical interference may occur as a result.  
• Leave at least 60cm of space from the wall  
The motor may overheat, causing malfunction as a result.  
• Avoid a location where sensors are exposed to direct wind  
The unit may not operate properly.  
• Avoid a location where curtains, etc., come into contact with the intake or exhaust port.  
Curtains, etc., may become dirty or malfunction may occur as a result.  
EFFECTIVE USAGE  
• Stable surface with sufficient air circulation  
• Near smoking area  
Air pollution is detected quickly.  
ABOUT THE FILTER  
• Do not wash and reuse Apatite HEPA filter and deodorization filter. It doesn’t have effect, and they  
become an electric shock and the cause of the trouble.  
• Small dust and odors such as tobacco smoke rise and accumulate at the top of the room.  
• Large dust such as pollen and house dust accumulate at the bottom of the room.  
• The wall, etc., behind the exhaust port may become dirty as time passes. When using the unit for  
extensive period in the same location, use a vinyl sheet, etc., to prevent the wall from becoming dirty.  
In addition, periodical clean the wall, etc.  
E-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NAMES OF PARTS  
It can’t remove the noxious substances  
(carbon monoxide etc.) of cigarette.  
MAIN UNIT DISPLAY  
*
Filter timer lamp  
AUTO operation lamp  
Fan level lamps  
Tobacco smoke mode operation lamp  
Power lamp  
*
(Lights when the power plug is  
Pollen mode operation lamp  
inserted into the wall outlet)  
OFF timer display lamps  
(set using remote control)  
Plasmacluster  
Clean-sign lamp  
Silent  
Median Max  
Remote control receiver  
High  
The color changes when the air is dirty  
Very dirty (red)  
Clean (green) Little dirty (orange)  
Odor sensor  
Dust sensor  
ABOUT THE CLEAN-SIGN LAMP  
(Detects odors such as tobacco  
smoke, incense, pets, cosmetics,  
(Detects dust, smoke,  
pollen, house dust, etc.)  
• The dust sensor displays a clean sign depending on  
the relative change of the environment at the time the  
power plug is inserted in the wall outlet and after.  
• When the air is extremely dirty at the time the power  
plug is inserted, the clean sign lamp may light green  
since the polluted state is the environment which the  
sensor bases the pollution rate on.  
etc.)  
EXPLODED  
DIAGRAM  
• In this case, switch manually to desirable operation as  
effective operation can’t be done in auto operation.  
To reset the base pollution rate of the clean-sign lamp  
remove and insert the power plug again the room air  
becomes clean.  
MODE-ON/OFF button  
(Used to select operations or turn the  
unit off)  
Main unit  
HEPA filter (white)  
(Dust collection filter)  
(W/ apatite antibacterial filter)  
Stamina-power carbon (black)  
(Deodorization filter)  
Pre-filter  
Front panel  
Remote control  
Hook  
Stand  
(Be sure to mount for tabletop instal-  
lation)  
Thumbscrew  
E-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLUSTER ION LAMP  
Cluster ion operation is selected using the remote control.  
Blue light  
When the cluster ion operation is in the Clean mode or AUTO cluster ion mode and the  
air in the room is dirty, the light turns on and the unit will operate in the Clean mode.  
Green light  
When the cluster ion operation is in the Refresh mode or AUTO cluster ion mode and  
the air in the room is dirty, the light turns on and the unit will operate in the Refresh  
mode.  
Light off  
No cluster ions are generated.  
If the lamp is bright when sleeping, or if the ion generation noise is irritating, turn off the  
cluster ion operation.  
ACCESSORIES  
Remote control  
(1 unit)  
Battery  
BACK  
(AA battery X  
2 units)  
When using on tabletop  
Stand  
(1 unit)  
Thumbscrew  
(2 units)  
Handle  
Located on  
bottom of  
stand  
Exhaust port  
When using this product to a wall  
Wall mounting  
bracket 1  
Wall mounting  
bracket 2  
Wood screw  
(4 units)  
Power cord  
Power plug  
Small screw  
(2 units)  
Cushions  
(2 units)  
E-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
WHEN USING THE UNIT WITH  
A MOUNTED WALL  
WHEN USING THE UNIT ON A  
TABLETOP  
MOUNTING THE STAND  
CAUTION  
Remove the front panel.  
• When mounting the air purifier to the wall, the  
mounted wall will become dirty as time passes.  
To prevent this, place a vinyl sheet, etc.,  
around the unit.  
1 • At this time, also remove the pre-filter,  
stamina-power carbon and the HEPA  
filter.  
1
• A wall side to install is to choose the place to  
have the strength done firmly.  
Front panel  
2
1
• In the case of a wall or concrete wall with little  
strength, request installation to a specialist  
such as an electric appliance shop, etc.  
• Do not install in a location with heavy lamp-  
black, such as in a kitchen, etc. The unit sur-  
face may crack as a result.  
Determine the mounting location  
1 Leave space around the bracket by referring  
to the illustration below. The unit cannot be  
mounted if there is insufficient spacing  
around the bracket.  
Place the unit with its front  
2 side facing down on a flat  
and stable surface.  
• Place a soft cloth, etc., to prevent  
damaging the unit.  
75cm or more  
69cm or more from  
the ceiling  
Size of main  
unit  
75cm or more  
75cm or more  
Mounting  
bracket 1  
Insert the tabs on the stand  
60cm or more from  
sidewall  
60cm or more  
from sidewall  
3 into the holes on the main  
unit and fix the stand using  
the included thumbscrews  
(2 units).  
Holes  
Tabs  
CAUTION  
Mount on a flat sur-  
face  
• Do not mount the unit to  
a location that is not flat  
such as a wall with a  
door header, etc.  
Do not mount the unit to  
a thin wall with little  
strength such as a plas-  
terboard, etc. The unit  
may fall and can be very  
dangerous.  
Thumb-  
screws  
E-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mount mounting bracket 1  
Place the 2 cushions  
2 • Install it after you ask a specialist and you  
4
can get the confirmation of the strength.  
• Mount the bracket using the included wood  
screws (long screws) so that it level.  
Use 4 wood screws (long screws)  
Cushions (2 units)  
Mount the main unit  
5(1) Align the horizontal positions of mount-  
Wood  
ing brackets 1 and 2 and hook the bracket  
2 to bracket 1.  
Mounting  
bracket 1  
(2) Hold the bot-  
tom of the main  
Wood screws  
(4 units)  
unit, pull the  
unit towards  
you and then  
pull down.  
Use 3 wood screws (long screws)  
Wood  
Mounting  
bracket 1  
Check the installation  
6 • Check to make sure that the tabs on mount-  
ing bracket 2 are securely mounted to the  
tabs on mounting bracket 1.  
• Check that the power cord is not pinched.  
Wood screws  
(3 units)  
Mount mounting bracket 2 to the  
REMOVING THE UNIT  
3 main unit  
Mount the bracket to the back of the main unit  
using the included small screws (2 units).  
Pull the bottom of the unit towards you and then  
lift.  
Do not use wood screws  
(long screws)  
NOTES  
• When removing  
the unit, use a firm  
stand.  
• Disconnect the power  
cord before remov-  
ing the unit.  
Mounting bracket 2  
Small screws  
(2 units)  
Download from Www.Somanuals.Eco-m7. All Manuals Search And Download.  
PREPARATION  
Be sure to remove the power plug from the wall outlet.  
INSTALLING THE FILTERS  
To maintain the quality of the filters, they are installed in the main unit within polyvinyl bags.  
Be sure to remove the filters from the polyvinyl bags before using the unit.  
1
Remove the filters  
1 Place the unit facing up  
Place the unit on a table, etc., so that the  
Place so stand  
does not touch  
surface  
stand does not contact the surface.  
Soft cloth  
Table, etc.  
1
2 Remove the front panel  
Front panel  
2
Press in the hook on the bottom of the front  
panel and lift to remove.  
2
1
1
Hook  
Prefilter  
Remove the pre-filter, and  
then remove the stamina-  
power carbon (black) and  
HEPA filter (white) that are  
inside the polyvinyl bags.  
3
Stamina-power carbon  
INSERTING BATTERIES IN THE REMOTE CONTROL  
About the batteries  
• The battery life is about 1 year.  
Replace the batteries when the remote con-  
trol becomes inoperative.  
Remove the  
1 back cover  
Press and slide the  
back cover to re-  
move.  
• Incorrect usage of the batteries may cause  
battery fluid leakage and/or damage. Take  
caution of the following when handling:  
• When replacing the batteries, replace  
both batteries with new ones of the same  
type. (Use AA alkaline batteries (2 units)  
or AA manganese batteries (2 units).)  
• When not using the unit or remote con-  
trol for an extensive period, remove the  
batteries.This prevents malfunction of the  
remote control from battery fluid leakage.  
*The included batteries are for initial use only  
and may deplete before 1 year.  
Insert batteries  
2
Insert batteries with  
and  
as shown  
below.  
Close the back  
3 cover  
E-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Tabs  
HEPA filter  
2
1
Install the filter  
Remove the HEPA filter from  
the polyvinyl bag and install it  
in the main unit with the  
display facing up.  
Insert so that the tabs on the HEPA filter  
are facing toward you.  
Proper operation cannot be achieved when  
installing the filter backwards.  
Stamina-power carbon  
Remove the stamina-power car-  
bon from the polyvinyl bag and  
install it in the main unit.  
Make sure the tabs on the HEPA filter remain vis-  
ible.  
2
3 Install the pre-filter  
Insert the 4 tabs on the pre-filter in the holes of the  
main unit.  
Back of front panel  
Replacement label  
Fill in the usage start date on  
4
the replacement label affixed on  
the back of the front panel and  
then mount the front panel.  
Use the date as a guide for the filter replacement  
period.  
USING THE REMOTE CONTROL  
• Operate the remote control facing the main unit (re-  
ceiver).  
• The signal range is about 7m (front).  
• Make sure there are no objects blocking the path of the  
signal.  
Receiver  
Transmitter  
• A sound will be heard from the main unit when a signal  
is received.  
NOTE  
• Avoid strong impact on the remote control. In addition,  
do not wet the remote control or place it under direct  
sunlight or near a stove, etc. Malfunction may occur as  
a result.  
E-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
For the first 30 seconds after the power plug is inserted  
into the wall outlet, the unit will check the conditions of  
the air. If operation is set to ON during this time, the  
Clean sign lamp will alternately flash in green, orange  
and red. During this time, the Cluster ion lamp will light  
blue and the unit will be in the Clean mode.  
OPERATION  
Operations available with  
main unit  
MAIN UNIT OPERATION  
• AUTO operation  
• Silent operation  
• Median level operation  
• High level operation  
• Max level operation  
Tobacco smoke mode  
*
operation  
• Pollen mode operation  
MODE-ON/OFF button  
Plasmacluster  
Cluster ion lamp  
The unit will start operation when the MODE-ON/OFF button is pressed.  
(The unit will start operation in AUTO mode)  
• During operation, the cluster ion lamp will light.  
(During start of operation, the cluster ion mode will be AUTO)  
The operation mode suitable for the usage condition can be set.  
Stop  
AUTO operation  
The fan level is automatically switched (High, Median, Silent) depend-  
ing on the amount of pollution in the air detected by the dust sensor for  
efficient air purification.  
Silent operation  
The unit will operate using little air.  
Median ~ Max operation  
The unit will operate with fan level of median, high or max.  
Tobacco smoke mode operation  
*
The unit will operate in High for 10 minutes, then the unit will return to  
the AUTO mode.  
It can’t remove the noxious  
substances (carbon monoxide  
etc.) of cigarette.  
10 minutes: High fan level  
AUTO mode operation  
*
Pollen mode operation  
The unit will operate in High for 10 minutes, then the unit will alternately  
operate between Median and High.  
10 minutes: High fan level  
20 minutes: median level  
20 minutes: High fan level  
E-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operations available with  
remote control  
• Fan level manual opera-  
tion  
• Fan level AUTO operation  
• Silent operation  
• Max operation  
REMOTE CONTROL  
OPERATION  
To start operation, press the ON/OFF button.  
A short beep will sound and operation will start in the  
AUTO mode.  
Tobacco smoke mode  
*
operation  
• Pollen mode operation  
• OFF timer setting  
• Cluster ion select  
AUTO cluster ion  
Clean mode  
To stop operation, press the ON/OFF button again.  
A long beep will sound and operation will stop.  
Refresh mode  
Transmitter  
AUTO (fan level) but-  
Manual (fan level)  
ton  
button  
The fan level switched auto-  
matically depending on the  
amount of pollution in the air.  
The fan level can be switched  
between Silent, Median, High  
and Max.  
Max operation button  
Used to quickly clean the air in  
the room.  
Silent operation but-  
ton  
Operation will be in the Silent  
mode with little air.  
Pollen mode opera-  
tion button  
Tobacco smoke  
*
The unit operates effectively  
when you suspect pollen in the  
air.  
mode operation but-  
ton  
Unit will operate effectively  
when smoking cigarettes, etc.  
RESET  
OFF timer button  
Used to set the OFF timer.  
The set time switches every  
time the button is pressed as  
shown below.  
Plasmacluster  
ON/OFF button  
AUTO  
OFF  
Used to start AUTO operation  
(short beep) and stop opera-  
tion (long beep).  
1 hour  
4 hours  
8 hours  
Filter reset button  
Press this button after replac-  
ing the filters.  
Cancel  
AIR PURIFIER  
• The remaining time is indi-  
cated by the lamp as time  
passes.  
• The unit will stop operation  
It can’t remove the noxious  
when the timer is up.  
*
substances (carbon monoxide  
At the start of operation, the  
Cluster ion mode is also set  
to AUTO.  
etc.) of cigarette.  
Cluster ion select button  
OFF button  
AUTO cluster ion button  
The generation of ions is stopped and the  
cluster ion lamp is turned off.  
The unit will switch between the Clean mode and  
Refresh mode automatically depending on the  
amount of pollution in the air detected by dust  
and odor sensor.  
Refresh button  
The unit will constantly operate in the Re-  
fresh mode.The Refresh mode maintains  
the balance of ions in the air for a refresh-  
ing effect.  
Clean button  
The unit will constantly operate in the Clean  
mode. The Clean mode is effective for removing  
mold fungus in the air.  
(Cluster ion lamp on (green))  
(Cluster ion lamp on (blue))  
If the room smells especially moldy, operate the unit in the Clean mode.  
Download from Www.Somanuals.Eco-m1. 1All Manuals Search And Download.  
CARE AND MAINTENANCE  
(To maintain the best performance of this product, please clean the unit periodically.)  
When cleaning, be sure to remove the power plug from the wall outlet. In addition, never  
handle the power plug with wet hands.  
Electrical shock and/or bodily injury may occur as a result.  
MAIN UNIT  
FILTERS  
For soiling on the main unit and the installed  
surface, clean as early as possible. Stubborn  
dirt may be hard to remove.  
Clean using the nozzle of a vacuum  
cleaner without removing the pre-filter.  
Dry wipe with a soft cloth  
For stubborn dirt, wipe with a soft cloth damp-  
ened with water or warm water of 40°C or less.  
Do not use volatile fluids  
Benzene, paint thinner, polishing powder, etc.,  
may damage the unit surface.  
Do not use detergents  
Detergent ingredients may damage the unit  
surface.  
NOTE  
Do not get wet  
Never apply water on the unit.  
Never wash or clean the HEPA filter or  
stamina-power carbon by directly con-  
tacting the nozzle of a vacuum cleaner.  
This will greatly decrease the perform-  
ance of the filters.  
ODOR SENSOR  
DUST SENSOR  
The sensitivity of the sensors will be come  
unstable if the odor or dust sensor is dirty or  
blocked.  
Remove dust on the surfaces of the sensor  
openings using a vacuum cleaner.  
Odor sensor  
Dust sensor  
Download from Www.Somanuals.Eco-m1. 2All Manuals Search And Download.  
GUIDE FOR LIFE OF FILTERS  
The replacement period differs depending on the usage hours and  
location of installation.  
Some of the odor ingredients adsorbed by the filters become separated  
and are discharged through the exhaust port as odor.  
Depending on the usage environment, this odor may become strong in  
several months and the exhaust port may smell.  
If dust or odors cannot be removed easily, replace the filters.  
(Refer to page1, FOR UNDERSTANDING THE PRODUCT)  
Guide for filter replacing timing  
• The following is a guide from JEM 1467 by Japan Electrical Manufacturers Association in  
Japan, and in JEM 1467, the replacement period is set as when smoking 10 cigarettes per  
day and the dust collection/deodorization power is reduced by half than that of new filters.  
• HEPA filter  
About 5 years after opening  
• Stamina-power carbon About 5 years after opening  
• The filter timer lamp is programmed to light in about 5 years, when using the unit for 12  
hours everyday, in order to indicate accumulated usage time of the guide above.  
• The filter timer lamp is to be used only as a guide.  
• The operation hours are kept in memory even when removing the power plug for  
transportation to another room, etc.  
REPLACING THE FILTERS  
See page 8 “Installing the filters” for the replacement method.  
1
After replacing the filters:  
2
Be sure to press the Reset button on the remote control with the power plug inserted in  
the wall outlet.  
A short beep will be heard and the operation hours stored in the memory will be reset. If  
the filter replacement lamp is on, the lamp will turn off.  
Fill in the usage start date of the filters on the date label in-  
3
cluded with the replacement filters. Affix the label on top of the  
replacement label that is already on the back of the front panel.  
Replacement filters  
• HEPA filter: 1 unit  
• Stamina-power carbon: 1 unit  
Model: FZ-40SEF  
Please ask for replacement filters at your dealer of purchase.  
Cautions concerning the disposal of filters  
Please dispose of replaced filters according to the local disposal laws and regulations.  
HEPA filter materials:  
• Filter: Polypropylene  
• Frame: Polyester  
Stamina-power carbon materials:  
• Deodorizer: Activated charcoal  
• Frame: Polyester  
Download from Www.SomanualsE.co-m1.3All Manuals Search And Download.  
TROUBLESHOOTING  
Before calling for repair, check the symptoms below for possible remedies, since the problem may  
not be a malfunction of the unit.  
SYMPTOM  
REMEDY (not a malfunction)  
• Has the batteries depleted?  
The remote control does not  
work  
• Are the batteries inserted with correct polarity?  
• Is a fluorescent lighting in the room flickering due to  
service life? (Refer to E-3)  
• Are the filters heavily dirty? (Refer to E-13)  
Odors and smoke cannot be  
removed easily  
• Is the opening of the dust sensor blocked or clogged?  
• Was the air already dirty when the power plug was  
inserted into the wall outlet? (Refer to E-4)  
The Clean sign lights green  
even when the air is dirty  
• The sensitivity of the sensor becomes unstable when  
the opening of the dust sensor is dirty or is clogged.  
Clean the dust around the sensor opening using a  
vacuum cleaner. (Refer to E-12)  
The Clean sign lights orange  
or red even when the air is  
clean  
• During the Clean mode (or Refresh mode), the cluster  
ion lamp color will not change.  
The cluster ion lamp remains  
green (blue) and does not  
change  
• This is the sound that is emitted when the unit is in  
the Refresh mode.  
Click, click  
A sound is  
heard from  
the unit  
If the sound is irritating, switch the unit to the Clean mode.  
• This is the sound that is emitted when the unit is gener-  
ating cluster ions.  
Tick, tick, tick  
If the sound is irritating, such as when sleeping, etc., set  
the Cluster ion mode to OFF.  
• The ozone generated by the cluster ion generator may  
have an odor. However, the density of ozone generated  
is very little and is harmless to the human body.  
Furthermore, the ozone decomposes quickly so it does  
not accumulate in the room.  
The discharged air smells  
• Is the unit installed in a location that is difficult for the  
sensors to detect cigarette smoke?  
• If the odor or dust sensor openings blocked or clogged?  
(In this case, clean the openings.) (Refer to E-12)  
The unit does not operate  
even when smoking ciga-  
rettes  
The applicable floor surface area is the surface area  
for when operating the unit in Max fan level.  
(According to Japan Electrical Manufacturers’ Asso-  
SPECIFICATIONS  
ciation JEM1467)  
Power supply  
220V-240V 50Hz  
Fan level adjustment  
Rated power  
Fan level  
Applicable floor surface  
Cord length  
Dimensions  
Weight  
Max  
39W  
High  
21W  
Median  
10W  
Silent  
4W  
Fan level  
operation  
240m3/hour 180m3/hour 117m3/hour 30m3/hour  
~31m2  
2.5m  
415mm(W)X197mm(D)X572mm(H)(W/ stand)  
6.6kg  
About the reduction of standby power  
In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this product  
consumes about 0.8W of standby power.  
(At this time, the power lamp will be on) For the conservation of energy, remove the power plug when  
not using the unit  
E-14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Во исполнение Статьи 5 Закона Российской Федерации «О  
защите прав потребителей», а также Указа Правительства  
Российской Федерации № 720 от 16 июня 1997 г.  
устанавливается срок службы данной модели – 7 лет с  
момента производства при условии использования в  
строгом соответствии с инструкцией по эксплуатации и  
применяемыми техническими стандартами.  
Страна–изготовитель: Произведено в Японии  
Фирма–изготовитель: Шарп Корпорейшн  
Юридический адрес изготовителя:  
22–22 Нагайке–чо, Абено–ку,  
Осака 545–8522, Япония  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVICE PROCEDURE / SERVICE VORGEHENSWEISE  
SERVICE PROCEDURE - ONLY EFFECTIVE IN GERMANY  
Dear SHARP customer,  
SHARP machines are proprietary articles which are produced with precision and care according  
to most modern production methods.  
In case of proper handling and with considering of the instruction book, this machine will serve  
you well for a long time.  
Of course, a defect cannot be ruled out.  
If your appliance has a warrantyable defect in the period of warranty, please contact your dealer,  
where you bought the appliance. This dealer is your only contact person for any claim of war-  
ranty.  
As proof for repairs during Warranty period, you need the invoice of the machine.  
Please bring your defect appliances also to your dealer (where you bought the appliance) when  
the warranty period is over.  
SHARP ELECTRONICS (EUROPE) GMBH  
Parts & Technical Service  
SERVICE VORGEHENSWEISE - GILT NUR FÜR DEUTSCHLAND  
Lieber SHARP-Kunde  
SHARP- Geräte sind Markenartikel, die mit Präzision und Sorgfalt nach modernen  
Fertigungsmethoden hergestellt werden.  
Bei sachgemässer Handhabung und unter Beachtung der Bedienungsanleitung wird lhnen lhr  
Gerät lange Zeit gute Dienste leisten.  
Das Auftreten von Fehlern ist aber nie auszuschließen.  
Sollte lhr Gerät während der Gewährleistungsfrist einen gewährleistungspflichtigen Mangel  
aufweisen, so wenden Sie sich bitte an den Handelsbetrieb, bei dem Sie dieses Gerät erworben  
haben, denn dieser ist lhr alleiniger Ansprechpartner für jegliche Gewährleistungsansprüche.  
Als Nachweis lm Gewährleistungsfall dient lhr Kaufbeleg.  
Sollte sich nach Ablauf der Gewährlelstrungsfrist ein Fehier des Gerätes zeigen, so wenden Sie  
sich bitte auch in diesem Fall an den Handelsbetrieb, bei dem Sie dieses Gerät erworben  
haben.  
SHARP ELECTRONICS (EUROPE) GMBH  
Parts & Technical Service  
SHARP CORPORATION  
OSAKA, JAPAN  
TINS-A040KKRZ 02EK 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Shark Iron GI472 User Manual
Sharp Cash Register ER 3231 User Manual
Sharp PDAs Smartphones YO P5B User Manual
Sony Projector CX75 User Manual
Spectra Laser Level QM75 User Manual
Sprint Nextel Laptop S205s User Manual
Stamina Products Exercise Bike UX2 User Manual
Sun Microsystems Network Card GigaSwift Ethernet Adapter User Manual
Swann DVR DVR16 8500AI User Manual
SWR Sound Musical Instrument Amplifier Bass Combo Amplifier User Manual