Sharp Air Cleaner FU 40SE K User Manual

R
FU-40SE-K  
AIR PURIFIER  
OPERATION MANUAL  
Tabletop / wall-mounting type  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ENGLISH  
FEATURES  
Cluster Ion Control  
The unit controls the ratio of minus cluster  
ions and plus cluster ions depending on  
the condition of the room.  
CONTENTS  
SAFETY PRECAUTIONS ........................ E-2  
• Clean mode  
Approximately the same amount of plus  
and minus cluster ions are discharged.  
This mode is effective for reducing floating  
mold and household odors in the air.  
• CAUTIONS CONCERNING THE USAGE  
OF THIS PRODUCT ....................................E-3  
• CAUTIONS WHEN MOUNTING THIS  
PRODUCT ON A WALL ...............................E-3  
• CAUTIONS CONCERNING  
THE INSTALLATION ....................................E-3  
• Refresh mode  
It is said that plenty of minus ions exist in  
places such as waterfalls or forests.  
In this operation mode, minus ions will be  
released in an increased rate, in order to  
bring the room air close to this condition.  
NAMES OF PARTS ................................. E-4  
• ACCESSORIES ...........................................E-5  
• AUTO cluster ion mode  
INSTALLATION ....................................... E-6  
The unit will switch between the Clean  
mode and Refresh mode automatically  
depending on the amount of pollution in  
the air detected by dust and odor sensor.  
WHEN USING THE UNIT ON A TABLETOP .. E-6  
• WHEN WALL MOUNTING THE UNIT..........E-7  
PREPARATION........................................ E-8  
HEPA Filter  
• High-efficiency dust collection  
• INSTALLING THE FILTERS .........................E-8  
• INSERTING BATTERIES  
IN THE REMOTE CONTROL ......................E-8  
• USING THE REMOTE CONTROL...............E-9  
Stamina-power carbon  
Powerful deodorization by large particles  
of columnar charcoal.  
OPERATION .......................................... E-10  
• MAIN UNIT OPERATION .......................... E-10  
• REMOTE CONTROL OPERATION ...........E-11  
CARE AND MAINTENANCE................. E-12  
FOR UNDERSTANDING  
THE PRODUCT  
• MAIN UNIT................................................ E-12  
• FILTERS.................................................... E-12  
• GUIDE FOR LIFE OF FILTERS ................ E-13  
Some of the odor ingredients  
adsorbed by the filters become sepa-  
rated and are discharged through the  
exhaust port as odor.  
TROUBLE SHOOTING.......................... E-14  
SPECIFICATIONS ................................. E-14  
Depending on the usage environment,  
this odour may become strong after  
several months and the exhaust port  
may smell.  
In this case, purchase an exchange  
filter FZ-40SEF of the option goods,  
and replace the filters.  
Thank you for purchasing the SHARP FU-40SE.  
Please read this manual carefully for the correct  
usage.Before using this product, be sure to read  
“Safety precautions.”  
After reading this manual, retain it in a conven-  
ient location for future reference.  
This product is for household use only.  
This equipment complies with the  
requirements of Directives 89/  
336/EEC and 73/23/EEC as  
amended by 93/68/EEC.  
E-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY PRECAUTIONS  
• Do not use the unit if the power cord or plug is damaged or the connection to the wall  
outlet is loose.  
Electrical shock, short circuit and/or fire may occur as a result.  
• Do not damage, break, coat, forcefully bend, pull, twist,bundle, pinch or place heavy objects  
on the power cord.  
If the power cord is damaged, fire and/or electrical shock may occur as a result.  
• Use AC 220~240V only.  
• Do not modify. Repair and disassembly of this product are to be performed by authorized  
service personnel only.  
Fire, electrical shock and/or bodily injury may occur if not.  
For repair, contact your dealer or the nearest Sharp Service Center.  
• Periodically remove dust from the power plug  
Accumulated dust on the power plug may cause bad insulation from humidity, etc.  
Fire and/or electrical shock may occur as a result.  
• When cleaning the unit, be sure to remove the power plug from the wall outlet.  
In addition, never handle the power plug with wet hands.  
Electrical shock and/or bodily injury may occur as a result.  
• Do not use the unit where there are oil ingredients such as cooking oil, etc., in the air.  
Cracking of the unit surface may occur as a result.  
• Do not wipe the unit with benzene or paint thinner. Also, do not spray insecticides on the  
unit.  
Cracking, electrical shock and/or fire may occur as a result.  
• Do not operate the unit when using indoor smoke-generating insecticides.  
Chemical ingredients may accumulate within the unit and then discharge from the exhaust port  
when the unit operates. Discharge of such chemicals may be unhealthy to your body.  
• Do not allow the unit to intake flammable gases, sparks from lit cigarettes, incense, etc.  
The unit may ignite as a result.  
• Do not use the unit where it is humid, such as in a bathroom, etc., or where the unit may  
get wet.  
Electrical shock and/or malfunction may occur as a result.  
• Do not insert fingers or foreign objects into the intake or exhaust ports.  
Electrical shock and/or malfunction may occur as a result.  
• When mounting to a wall, select a sturdy wall or studding.  
The unit may fall if not.  
• When removing the power plug, always hold the plug and never pull the cord.  
Electrical shock and/or fire from short circuit may occur as a result.  
• Ventilate when using the unit along with a heating appliance.  
Carbon monoxide poisoning may occur as a result.  
• Remove the power plug when not using the unit.  
• If the supply cord is damaged, it must be replaced by the manufacturer or its service agent  
or similarly qualified person in order to avoid a hazard.  
• The batteries must be disposed of safely.  
E-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUTIONS CONCERNING THE USAGE OF THIS PRODUCT  
• Do not block the intake and exhaust ports.  
• Do not use the unit near or on hot objects, such as a stove, etc. Also, do not use the unit where it may  
come into contact with steam.  
• Do not use the unit on its side.  
Deformation, malfunction and/or overheating of the motor may occur as a result.  
• Do not install when there is generation of lampblack, such as in a kitchen, etc.  
• Do not use detergent when cleaning the unit.  
The unit surface may become damaged or cracked.  
In addition, the sensors may malfunction as a result.  
• When transporting the unit, always hold the handle on the back of the unit.  
Holding the front panel when carrying may cause it to detach, thus dropping the unit and resulting in  
bodily injury.  
CAUTIONS WHEN MOUNTING THIS PRODUCT ON A WALL  
• Never mount the unit to a thin wall or plasterboard of insufficient strength.The unit may fall as  
a result.  
• When mounting the unit to a wall, remove the front panel and hold the main unit.  
Holding the front panel may cause it to become detached, thus dropping the unit and resulting in  
bodily injury.  
• Do not install when there is generation of lampblack, such as in a kitchen, etc.  
The unit surface may crack or the sensors may malfunction as a result.  
CAUTIONS CONCERNING THE INSTALLATION  
DO NOT USE THE REMOTE CONTROL IN THE FOLLOWING LOCATIONS  
• Locations where there are inverter lighting equipment or electronic spontaneous lighting equip-  
ment  
The remote control may become inoperative. In this case, move away from such lighting equipment  
or change direction.  
• Location exposed to direct sunlight  
The unit may not received signals from the remote control  
INSTALLATION  
• Leave at least 2m of space from televisions and radios  
Electrical interference may occur if not.  
• Leave at least 60cm of space from the wall  
The motor may overheat, causing malfunction if not.  
• Avoid a location where sensors are exposed to direct wind  
The unit may not operate properly.  
• Avoid a location where curtains, etc., come into contact with the intake or exhaust port.  
Curtains, etc., may become dirty or malfunction may occur as a result.  
EFFECTIVE USAGE  
• Place on a stable surface with sufficient air circulation  
• Near smoking area  
Air pollution is detected quickly.  
ABOUT THE FILTER  
• Do not wash or reuse Apatite HEPA filter and deodorization filter.  
• Small dust particles and odors such as tobacco smoke rise and accumulate at the top of the room.  
• Large dust such as pollen and house dust accumulate at the bottom of the room.  
• The wall, etc., behind the exhaust port may become dirty as time passes. When using the unit for  
extensive period in the same location, use a vinyl sheet, etc., to prevent the wall from becoming dirty.  
In addition, periodically clean the wall, etc.  
E-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NAMES OF PARTS  
It can not remove the noxious substances (carbon  
monoxide etc.) from cigarette smoke.  
*
MAIN UNIT DISPLAY  
Filter timer lamp  
AUTO operation lamp  
Fan level lamps  
Tobacco smoke mode operation lamp  
Power lamp  
*
(Lights when the power plug is  
Pollen mode operation lamp  
inserted into the wall outlet)  
OFF timer display lamps  
(set using remote control)  
Plasmacluster  
Clean-sign lamp  
Silent  
Median Max  
Remote control receiver  
High  
The colour changes when the air is dirty  
Very dirty (red)  
Clean (green) Little dirty (orange)  
Odor sensor  
Dust sensor  
ABOUT THE CLEAN-SIGN LAMP  
(Detects odors such as tobacco  
smoke, incense, pets, cosmetics,  
(Detects dust, smoke,  
pollen, house dust, etc.)  
• The dust sensor displays a clean sign depending on  
the environment at the time the power plug is inserted  
in the wall outlet.  
etc.)  
• When the air is extremely dirty at the time the power  
plug is inserted, the clean sign lamp may light green  
since the polluted state is the environment which the  
sensor bases the pollution rate on.  
EXPLODED  
DIAGRAM  
• In this case, switch manually to the desirable operation  
mode as effective operation can’t be done in auto  
operation.  
To reset the base pollution rate of the clean-sign lamp  
remove and insert the power plug.  
MODE-ON/OFF button  
(Used to select operations or turn the  
unit off)  
Main unit  
HEPA filter (white)  
(Dust collection filter)  
(W/ apatite antibacterial filter)  
Stamina-power carbon (black)  
(Deodorization filter)  
Pre-filter  
Front panel  
Remote control  
Hook  
Stand  
(Be sure to mount for tabletop instal-  
lation)  
Thumbscrew  
E-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLUSTER ION LAMP  
Cluster ion operation is selected using the remote control.  
Blue light  
When the cluster ion operation is in the Clean mode or AUTO cluster ion mode and the  
air in the room is dirty, the light turns on and the unit will operate in the Clean mode.  
Green light  
When the cluster ion operation is in the Refresh mode or AUTO cluster ion mode and  
the air in the room is clean, the light turns on and the unit will operate in the Refresh  
mode.  
Light off  
No cluster ions are generated.  
If the lamp is to bright when sleeping, or if the ion generation noise is irritating, turn off  
the cluster ion operation.  
ACCESSORIES  
Remote control  
(1 unit)  
Battery  
BACK  
(AA battery X  
2 units)  
When used on a tabletop  
Stand  
(1 unit)  
Thumbscrew  
(2 units)  
Handle  
Located on  
bottom of  
stand  
Exhaust port  
When wall mounting this product  
Wall mounting  
bracket 1  
Wall mounting  
bracket 2  
Wood screw  
(4 units)  
Small screw  
Power cord  
Power plug  
(2 units)  
Cushions  
(2 units)  
E-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
WHEN WALL MOUNTING  
CAUTION  
WHEN USING THE UNIT ON A  
TABLETOP  
FIXING THE STAND  
Remove the front panel.  
• When mounting the air purifier on a wall, the  
wall will become dirty as time passes.To pre-  
vent this, place a vinyl sheet, etc., around the  
unit.  
1 • At this time, also remove the pre-filter,  
stamina-power carbon and the HEPA  
filter.  
1
• Ensure that the wall is suitable for mounting  
the air purifier.  
Front panel  
2
1
• Do not install in a location with heavy smoke,  
such as in a kitchen, etc.The unit surface may  
crack as a result.  
Determine the mounting location  
1 Leave space around the bracket by referring  
to the illustration below. The unit cannot be  
mounted if there is insufficient spacing  
around the bracket.  
Place the unit with its front  
2 side facing down on a flat  
and stable surface.  
• Place a soft cloth, etc., to prevent  
damaging the unit.  
75cm or more  
69cm or more from  
the ceiling  
Size of main  
unit  
75cm or more  
75cm or more  
Mounting  
bracket 1  
60cm or more from  
sidewall  
60cm or more  
from sidewall  
Insert the tabs on the stand  
3 into the holes on the main  
unit and fix the stand using  
the supplied thumbscrews  
(2 units).  
Holes  
Tabs  
CAUTION  
Mount on a flat sur-  
face  
• Do not mount the unit to  
a thin wall with little  
strength such as a plas-  
terboard, etc. The unit  
may fall and can be very  
dangerous.  
Thumb-  
screws  
E-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mount mounting bracket 2 to the  
main unit  
2
3
REMOVING THE UNIT  
Mount the bracket to the back of the main unit  
using the small screws included.  
Pull the bottom of the unit towards you and then  
lift.  
NOTES  
Mounting bracket 2  
• When removing  
the unit disconnect  
the power cord.  
Small screws  
(2 units)  
Place the cushions as shown  
Cushions (2 units)  
Mount the main unit  
4(1) Align the horizontal positions of mounting  
brackets 1 and 2 and hook the bracket 2 to  
bracket 1.  
(2) Hold the bottom  
of the main unit,  
pull the unit to-  
wards you and  
then pull down.  
Check the installation  
5 • Check to make sure that the tabs on mount-  
ing bracket 2 are securely mounted to the  
tabs on mounting bracket 1.  
• Check that the power cord is not pinched.  
Download from Www.Somanuals.Eco-m7. All Manuals Search And Download.  
PREPARATION  
Be sure to remove the power plug from the wall outlet.  
INSTALLING THE FILTERS  
To maintain the quality of the filters, they are installed in the main unit within polyvinyl bags.  
Be sure to remove the filters from the polyvinyl bags before using the unit.  
1
Remove the filters  
1 Place the unit facing up  
Place the unit on a table, etc., so that the  
Place so stand  
does not touch  
the surface  
stand does not touch the surface.  
Soft cloth  
Table, etc.  
1
2 Remove the front panel  
Front panel  
2
Press in the hook on the bottom of the front  
panel and lift to remove.  
2
1
1
Hook  
Prefilter  
Remove the pre-filter, and  
then remove the stamina-  
power carbon (black) and  
HEPA filter (white) that are  
inside the polyvinyl bags.  
3
Stamina-power carbon  
INSERTING BATTERIES IN THE REMOTE CONTROL  
About the batteries  
Remove the  
1 back cover  
• The battery life is about 1 year.  
Replace the batteries when the remote con-  
Press and slide the  
trol becomes inoperative.  
• Incorrect usage of the batteries may cause  
back cover to re-  
move.  
battery fluid leakage and/or damage. Take  
caution of the following when handling:  
• When replacing the batteries, replace  
both batteries with new ones of the same  
type. (Use AA alkaline batteries (2 units)  
or AA manganese batteries (2 units).)  
• When not using the unit or remote con-  
trol for an extensive period, remove the  
batteries.This prevents malfunction of the  
remote control from battery fluid leakage.  
Insert batteries  
2
Insert batteries with  
and  
as shown  
below.  
Close the back  
3 cover  
E-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Tabs  
HEPA filter  
2
1
Install the filter  
Remove the HEPA filter from  
the polyvinyl bag and install it  
in the main unit with the  
display facing up.  
Insert so that the tabs on the HEPA filter  
are facing you.  
Proper operation cannot be achieved if  
installed incorrectly.  
Stamina-power carbon  
Remove the stamina-power car-  
bon from the polyvinyl bag and  
install it in the main unit.  
Make sure the tabs on the HEPA filter remain vis-  
ible.  
2
3 Install the pre-filter  
Insert the 4 tabs on the pre-filter in the holes of the  
main unit.  
Back of front panel  
Replacement label  
Fill in the usage start date on  
4
the replacement label affixed on  
the back of the front panel and  
then mount the front panel.  
Use the date as a guide for the filter replacement  
period.  
USING THE REMOTE CONTROL  
• Operate the remote control facing the main unit (re-  
ceiver).  
• The signal range is about 7m (front).  
Receiver  
• Make sure there are no objects blocking the path of the  
Transmitter  
signal.  
• A Beep will be heard from the main unit when a signal is  
received.  
NOTE  
• Avoid strong impact on the remote control. In addition,  
do not wet the remote control or place it under direct  
sunlight or near a stove, etc. Malfunction may occur.  
E-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
For the first 30 seconds after the power plug is inserted  
into the wall outlet, the unit will check the conditions of  
the air. If operation is set to ON during this time, the  
Clean sign lamp will alternately flash in green, orange  
and red. During this time, the Cluster ion lamp will light  
blue and the unit will be in the Clean mode.  
OPERATION  
Operations available with  
main unit  
MAIN UNIT OPERATION  
• AUTO operation  
• Silent operation  
• Median level operation  
• High level operation  
• Max level operation  
Tobacco smoke mode  
*
operation  
• Pollen mode operation  
MODE-ON/OFF button  
Plasmacluster  
Cluster ion lamp  
The unit will start operation when the MODE-ON/OFF button is pressed.  
(The unit will start operation in AUTO mode)  
• During operation, the cluster ion lamp will light.  
(During start of operation, the cluster ion mode will be AUTO)  
The operation mode suitable for the usage condition can be set.  
Stop  
AUTO operation  
The fan level is automatically switched (High, Median, Silent) depend-  
ing on the amount of pollution in the air detected by the dust sensor for  
efficient air purification.  
Silent operation  
The unit will operate using little air.  
Median ~ Max operation  
The unit will operate with fan level of median, high or max.  
Tobacco smoke mode operation  
*
The unit will operate in High for 10 minutes, then the unit will return to  
the AUTO mode.  
It can not remove the noxious  
substances (carbon monoxide  
etc.) from cigarette smoke.  
10 minutes: High fan level  
AUTO mode operation  
*
Pollen mode operation  
The unit will operate in High for 10 minutes, then the unit will alternately  
operate between Median and High.  
10 minutes: High fan level  
20 minutes: Median level  
20 minutes: High fan level  
E-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operations available with  
remote control  
• Fan level manual opera-  
tion  
• Fan level AUTO operation  
• Silent operation  
• Max operation  
REMOTE CONTROL  
OPERATION  
To start operation, press the ON/OFF button.  
A short beep will sound and operation will start in the  
AUTO mode.  
Tobacco smoke mode  
*
operation  
• Pollen mode operation  
• OFF timer setting  
• Cluster ion select  
AUTO cluster ion  
Clean mode  
To stop operation, press the ON/OFF button again.  
A long beep will sound and operation will stop.  
Refresh mode  
Transmitter  
AUTO (fan level) but-  
Manual (fan level)  
ton  
button  
The fan speed depends upon  
the amount of pollution in the  
air.  
The fan level can be switched  
between Silent, Median, High  
and Max.  
Max operation button  
Used to quickly clean the air in  
the room.  
Silent operation but-  
ton  
Operation will be in the Silent  
mode with little air.  
Pollen mode opera-  
tion button  
Tobacco smoke  
*
The unit operates effectively  
when you suspect pollen in the  
air.  
mode operation but-  
ton  
Unit will operate effectively  
when smoking cigarettes, etc.  
RESET  
OFF timer button  
Used to set the OFF timer.  
The set time switches every  
time the button is pressed as  
shown below.  
ON/OFF button  
Plasmacluster  
AUTO  
OFF  
Used to start AUTO operation  
(short beep) and stop opera-  
tion (long beep).  
1 hour  
4 hours  
8 hours  
Filter reset button  
Press this button after replac-  
ing the filters.  
Cancel  
AIR PURIFIER  
• The remaining time is indi-  
cated by the lamp as time  
passes.  
• The unit will stop operation  
It can not remove the noxious  
when the timer is up.  
*
substances (carbon monoxide  
At the start of operation, the  
Cluster ion mode is also set  
to AUTO.  
etc.) from cigarette smoke.  
Cluster ion select button  
OFF button  
AUTO cluster ion button  
The generation of ions is stopped and the  
cluster ion lamp is turned off.  
The unit will switch between the Clean mode and  
Refresh mode automatically depending on the  
amount of pollution in the air detected by the dust  
and odour sensor.  
Refresh button  
The unit will constantly operate in the Re-  
fresh mode.The Refresh mode maintains  
the balance of ions in the air for a refresh-  
ing effect.  
Clean button  
The unit will constantly operate in the Clean  
mode. The Clean mode is effective for removing  
mold fungus in the air.  
(Cluster ion lamp on (green))  
(Cluster ion lamp on (blue))  
If the room smells especially moldy, operate the unit in the Clean mode.  
Download from Www.Somanuals.Eco-m1. 1All Manuals Search And Download.  
CARE AND MAINTENANCE  
(To maintain the best performance of this product, please clean the unit periodically.)  
When cleaning, be sure to remove the power plug from the wall outlet. In addition, never  
handle the power plug with wet hands.  
Electrical shock and/or bodily injury may occur as a result.  
MAIN UNIT  
FILTERS  
For soiling on the main unit and the installed  
surface, clean as early as possible. Stubborn  
dirt may be hard to remove.  
Clean using the nozzle of a vacuum  
cleaner without removing the pre-filter.  
Dry wipe with a soft cloth  
For stubborn dirt, wipe with a soft cloth damp-  
ened with water or warm water of 40°C or less.  
Do not use volatile fluids  
Benzene, paint thinner, polishing powder, etc.,  
may damage the unit surface.  
Do not use detergents  
Detergent ingredients may damage the unit  
surface.  
NOTE  
Do not get wet  
Never apply water on the unit.  
Never wash or clean the HEPA filter or  
stamina-power carbon by directly con-  
tacting the nozzle of a vacuum cleaner.  
This will greatly decrease the perform-  
ance of the filters.  
ODOR SENSOR  
DUST SENSOR  
The sensitivity of the sensors will become  
unstable if the odor or dust sensor is dirty or  
blocked.  
Remove dust on the surfaces of the sensor  
openings using a vacuum cleaner.  
Odor sensor  
Dust sensor  
Download from Www.Somanuals.Eco-m1. 2All Manuals Search And Download.  
GUIDE FOR LIFE OF FILTERS  
The replacement period differs depending on the usage hours and  
location of installation.  
Some of the odor ingredients adsorbed by the filters become separated  
and are discharged through the exhaust port as odor.  
Depending on the usage environment, this odor may become strong in  
several months and the exhaust port may smell.  
If dust or odors cannot be removed easily, replace the filters.  
(Refer to page1, FOR UNDERSTANDING THE PRODUCT)  
Guide for filter replacing timing  
• The following is a guide from JEM 1467 by Japan Electrical Manufacturers Association in  
Japan, and in JEM 1467, the replacement period is set as when smoking 10 cigarettes per  
day and the dust collection/deodorization power is reduced by half that of new filters.  
• HEPA filter  
About 5 years after opening  
• Stamina-power carbon About 5 years after opening  
• The filter timer lamp is programmed to light in about 5 years, when using the unit for 12  
hours everyday, in order to indicate accumulated usage time of the guide above.  
• The filter timer lamp is to be used only as a guide.  
• The operation hours are kept in memory even when removing the power plug for  
transportation to another room, etc.  
REPLACING THE FILTERS  
See page 8 “Installing the filters” for the replacement method.  
1
After replacing the filters:  
2
Be sure to press the Reset button on the remote control with the power plug inserted in  
the wall outlet.  
A short beep will be heard and the operation hours stored in the memory will be reset. If  
the filter replacement lamp is on, the lamp will turn off.  
Fill in the usage start date of the filters on the date label in-  
3
cluded with the replacement filters. Affix the label on top of the  
replacement label that is already on the back of the front panel.  
Replacement filters  
• HEPA filter: 1 unit  
• Stamina-power carbon: 1 unit  
Model: FZ-40SEF  
Please ask for replacement filters at your dealer of purchase.  
Cautions concerning the disposal of filters  
Please dispose of replaced filters according to the local disposal laws and regulations.  
HEPA filter materials:  
• Filter: Polypropylene  
• Frame: Polyester  
Stamina-power carbon materials:  
• Deodorizer: Activated charcoal  
• Frame: Polyester  
Download from Www.SomanualsE.co-m1.3All Manuals Search And Download.  
TROUBLESHOOTING  
Before calling for repair, check the symptoms below for possible remedies, since the problem may  
not be a malfunction of the unit.  
SYMPTOM  
The remote control does not  
REMEDY (not a malfunction)  
• Have the batteries depleted?  
• Are the batteries inserted correctly?  
• Is a fluorescent lighting in the room flickering due to service  
life? (Refer to E-3)  
work  
• Are the filters heavily soiled? (Refer to E-13)  
Odors and smoke cannot be re-  
moved easily  
• Is the opening of the dust sensor blocked or clogged?  
• Was the air already dirty when the power plug was inserted  
into the wall outlet? (Refer to E-4)  
The Clean sign lights green  
even when the air is dirty  
• The sensitivity of the sensor becomes unstable when the  
opening of the dust sensor is dirty or is clogged.  
Clean the dust around the sensor opening using a vacuum  
cleaner. (Refer to E-12)  
The Clean sign lights orange or  
red even when the air is clean  
The cluster ion lamp remains  
green (blue) and does not  
change  
• During the Clean mode (or Refresh mode), the cluster ion lamp  
colour will not change.  
• This is the sound that is emitted when the unit is in t  
Refresh mode.  
h
e
A sound is  
heard from the  
unit  
Click, click  
If the sound is irritating, switch the unit to the Clean mode.  
• This is the sound that is emitted when the unit is generating  
cluster ions.  
If the sound is irritating, such as when sleeping, etc., set the  
Cluster ion mode to OFF.  
Tick, tick, tick  
• The ozone generated by the cluster ion generator may have  
an odor. However, the density of ozone generated is very little  
and is harmless to the human body. Furthermore, the ozone  
decomposes quickly so it does not accumulate in the room.  
The discharged air smells  
The unit does not operate even  
when smoking cigarettes  
• Is the unit installed in a location that is difficult for the sensors  
to detect cigarette smoke?  
• Are the odour and dust or dust sensor openings blocked or  
clogged? (In this case, clean the openings.)  
(Refer to E-12)  
The applicable floor surface area is the surface area for  
when operating the unit in Max fan level.  
(According to Japan Electrical Manufacturers’ Association  
JEM1467)  
SPECIFICATIONS  
Power supply  
220V-240V 50Hz  
Fan level adjustment  
Rated power  
Fan level  
Applicable floor surface  
Cord length  
Dimensions  
Weight  
Max  
39W  
High  
21W  
Median  
10W  
Silent  
4W  
Fan level  
operation  
240m3/hour 180m3/hour 117m3/hour 30m3/hour  
~31m2  
2.5m  
415mm(W)X197mm(D)X572mm(H)(W/ stand)  
6.6kg  
About the reduction of standby power  
In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this product  
consumes about 0.8W of standby power.  
(At this time, the power lamp will be on) For the conservation of energy, remove the power plug when  
not using the unit  
SHARP CORPORATION  
OSAKA, JAPAN  
TINS-A056KKRZ 02HK 1  
E-14  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Shark Vacuum Cleaner SV726 User Manual
Sharp Copier AR 153E N User Manual
Sony Cassette Player TC TX77 User Manual
Sony Computer Monitor PFM 510A1WU PFM 510A1WE PFM 510A1WJ User Manual
Sony DVD Recorder RDR GX3 User Manual
Sony Portable CD Player NE320 User Manual
SOYO Computer Hardware SY 6IZA User Manual
Sylvania VCR 6260VC User Manual
TANDBERG Flat Panel Television 150MXP User Manual
Tanita Scale BC 530 User Manual