R
FU-40SE-K
AIR PURIFIER
OPERATION MANUAL
Tabletop / wall-mounting type
Download from Www.Somanuals.com. All Manuals Search And Download.
ENGLISH
FEATURES
Cluster Ion Control
The unit controls the ratio of minus cluster
ions and plus cluster ions depending on
the condition of the room.
CONTENTS
SAFETY PRECAUTIONS ........................ E-2
• Clean mode
Approximately the same amount of plus
and minus cluster ions are discharged.
This mode is effective for reducing floating
mold and household odors in the air.
• CAUTIONS CONCERNING THE USAGE
OF THIS PRODUCT ....................................E-3
• CAUTIONS WHEN MOUNTING THIS
PRODUCT ON A WALL ...............................E-3
• CAUTIONS CONCERNING
THE INSTALLATION ....................................E-3
• Refresh mode
It is said that plenty of minus ions exist in
places such as waterfalls or forests.
In this operation mode, minus ions will be
released in an increased rate, in order to
bring the room air close to this condition.
NAMES OF PARTS ................................. E-4
• ACCESSORIES ...........................................E-5
• AUTO cluster ion mode
INSTALLATION ....................................... E-6
The unit will switch between the Clean
mode and Refresh mode automatically
depending on the amount of pollution in
the air detected by dust and odor sensor.
•
WHEN USING THE UNIT ON A TABLETOP .. E-6
• WHEN WALL MOUNTING THE UNIT..........E-7
PREPARATION........................................ E-8
HEPA Filter
• High-efficiency dust collection
• INSTALLING THE FILTERS .........................E-8
• INSERTING BATTERIES
IN THE REMOTE CONTROL ......................E-8
• USING THE REMOTE CONTROL...............E-9
Stamina-power carbon
Powerful deodorization by large particles
of columnar charcoal.
OPERATION .......................................... E-10
• MAIN UNIT OPERATION .......................... E-10
• REMOTE CONTROL OPERATION ...........E-11
CARE AND MAINTENANCE................. E-12
FOR UNDERSTANDING
THE PRODUCT
• MAIN UNIT................................................ E-12
• FILTERS.................................................... E-12
• GUIDE FOR LIFE OF FILTERS ................ E-13
Some of the odor ingredients
adsorbed by the filters become sepa-
rated and are discharged through the
exhaust port as odor.
TROUBLE SHOOTING.......................... E-14
SPECIFICATIONS ................................. E-14
Depending on the usage environment,
this odour may become strong after
several months and the exhaust port
may smell.
In this case, purchase an exchange
filter FZ-40SEF of the option goods,
and replace the filters.
Thank you for purchasing the SHARP FU-40SE.
Please read this manual carefully for the correct
usage.Before using this product, be sure to read
“Safety precautions.”
After reading this manual, retain it in a conven-
ient location for future reference.
This product is for household use only.
This equipment complies with the
requirements of Directives 89/
336/EEC and 73/23/EEC as
amended by 93/68/EEC.
E-1
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETY PRECAUTIONS
• Do not use the unit if the power cord or plug is damaged or the connection to the wall
outlet is loose.
Electrical shock, short circuit and/or fire may occur as a result.
• Do not damage, break, coat, forcefully bend, pull, twist,bundle, pinch or place heavy objects
on the power cord.
If the power cord is damaged, fire and/or electrical shock may occur as a result.
• Use AC 220~240V only.
• Do not modify. Repair and disassembly of this product are to be performed by authorized
service personnel only.
Fire, electrical shock and/or bodily injury may occur if not.
For repair, contact your dealer or the nearest Sharp Service Center.
• Periodically remove dust from the power plug
Accumulated dust on the power plug may cause bad insulation from humidity, etc.
Fire and/or electrical shock may occur as a result.
• When cleaning the unit, be sure to remove the power plug from the wall outlet.
In addition, never handle the power plug with wet hands.
Electrical shock and/or bodily injury may occur as a result.
• Do not use the unit where there are oil ingredients such as cooking oil, etc., in the air.
Cracking of the unit surface may occur as a result.
• Do not wipe the unit with benzene or paint thinner. Also, do not spray insecticides on the
unit.
Cracking, electrical shock and/or fire may occur as a result.
• Do not operate the unit when using indoor smoke-generating insecticides.
Chemical ingredients may accumulate within the unit and then discharge from the exhaust port
when the unit operates. Discharge of such chemicals may be unhealthy to your body.
• Do not allow the unit to intake flammable gases, sparks from lit cigarettes, incense, etc.
The unit may ignite as a result.
• Do not use the unit where it is humid, such as in a bathroom, etc., or where the unit may
get wet.
Electrical shock and/or malfunction may occur as a result.
• Do not insert fingers or foreign objects into the intake or exhaust ports.
Electrical shock and/or malfunction may occur as a result.
• When mounting to a wall, select a sturdy wall or studding.
The unit may fall if not.
• When removing the power plug, always hold the plug and never pull the cord.
Electrical shock and/or fire from short circuit may occur as a result.
• Ventilate when using the unit along with a heating appliance.
Carbon monoxide poisoning may occur as a result.
• Remove the power plug when not using the unit.
• If the supply cord is damaged, it must be replaced by the manufacturer or its service agent
or similarly qualified person in order to avoid a hazard.
• The batteries must be disposed of safely.
E-2
Download from Www.Somanuals.com. All Manuals Search And Download.
CAUTIONS CONCERNING THE USAGE OF THIS PRODUCT
• Do not block the intake and exhaust ports.
• Do not use the unit near or on hot objects, such as a stove, etc. Also, do not use the unit where it may
come into contact with steam.
• Do not use the unit on its side.
Deformation, malfunction and/or overheating of the motor may occur as a result.
• Do not install when there is generation of lampblack, such as in a kitchen, etc.
• Do not use detergent when cleaning the unit.
The unit surface may become damaged or cracked.
In addition, the sensors may malfunction as a result.
• When transporting the unit, always hold the handle on the back of the unit.
Holding the front panel when carrying may cause it to detach, thus dropping the unit and resulting in
bodily injury.
CAUTIONS WHEN MOUNTING THIS PRODUCT ON A WALL
• Never mount the unit to a thin wall or plasterboard of insufficient strength.The unit may fall as
a result.
• When mounting the unit to a wall, remove the front panel and hold the main unit.
Holding the front panel may cause it to become detached, thus dropping the unit and resulting in
bodily injury.
• Do not install when there is generation of lampblack, such as in a kitchen, etc.
The unit surface may crack or the sensors may malfunction as a result.
CAUTIONS CONCERNING THE INSTALLATION
DO NOT USE THE REMOTE CONTROL IN THE FOLLOWING LOCATIONS
• Locations where there are inverter lighting equipment or electronic spontaneous lighting equip-
ment
The remote control may become inoperative. In this case, move away from such lighting equipment
or change direction.
• Location exposed to direct sunlight
The unit may not received signals from the remote control
INSTALLATION
• Leave at least 2m of space from televisions and radios
Electrical interference may occur if not.
• Leave at least 60cm of space from the wall
The motor may overheat, causing malfunction if not.
• Avoid a location where sensors are exposed to direct wind
The unit may not operate properly.
• Avoid a location where curtains, etc., come into contact with the intake or exhaust port.
Curtains, etc., may become dirty or malfunction may occur as a result.
EFFECTIVE USAGE
• Place on a stable surface with sufficient air circulation
• Near smoking area
Air pollution is detected quickly.
ABOUT THE FILTER
• Do not wash or reuse Apatite HEPA filter and deodorization filter.
• Small dust particles and odors such as tobacco smoke rise and accumulate at the top of the room.
• Large dust such as pollen and house dust accumulate at the bottom of the room.
• The wall, etc., behind the exhaust port may become dirty as time passes. When using the unit for
extensive period in the same location, use a vinyl sheet, etc., to prevent the wall from becoming dirty.
In addition, periodically clean the wall, etc.
E-3
Download from Www.Somanuals.com. All Manuals Search And Download.
NAMES OF PARTS
It can not remove the noxious substances (carbon
monoxide etc.) from cigarette smoke.
*
MAIN UNIT DISPLAY
Filter timer lamp
AUTO operation lamp
Fan level lamps
Tobacco smoke mode operation lamp
Power lamp
*
(Lights when the power plug is
Pollen mode operation lamp
inserted into the wall outlet)
OFF timer display lamps
(set using remote control)
Plasmacluster
Clean-sign lamp
Silent
Median Max
Remote control receiver
High
The colour changes when the air is dirty
Very dirty (red)
Clean (green) Little dirty (orange)
Odor sensor
Dust sensor
ABOUT THE CLEAN-SIGN LAMP
(Detects odors such as tobacco
smoke, incense, pets, cosmetics,
(Detects dust, smoke,
pollen, house dust, etc.)
• The dust sensor displays a clean sign depending on
the environment at the time the power plug is inserted
in the wall outlet.
etc.)
• When the air is extremely dirty at the time the power
plug is inserted, the clean sign lamp may light green
since the polluted state is the environment which the
sensor bases the pollution rate on.
EXPLODED
DIAGRAM
• In this case, switch manually to the desirable operation
mode as effective operation can’t be done in auto
operation.
• To reset the base pollution rate of the clean-sign lamp
remove and insert the power plug.
MODE-ON/OFF button
(Used to select operations or turn the
unit off)
Main unit
HEPA filter (white)
(Dust collection filter)
(W/ apatite antibacterial filter)
Stamina-power carbon (black)
(Deodorization filter)
Pre-filter
Front panel
Remote control
Hook
Stand
(Be sure to mount for tabletop instal-
lation)
Thumbscrew
E-4
Download from Www.Somanuals.com. All Manuals Search And Download.
CLUSTER ION LAMP
Cluster ion operation is selected using the remote control.
Blue light
When the cluster ion operation is in the Clean mode or AUTO cluster ion mode and the
air in the room is dirty, the light turns on and the unit will operate in the Clean mode.
Green light
When the cluster ion operation is in the Refresh mode or AUTO cluster ion mode and
the air in the room is clean, the light turns on and the unit will operate in the Refresh
mode.
Light off
No cluster ions are generated.
If the lamp is to bright when sleeping, or if the ion generation noise is irritating, turn off
the cluster ion operation.
ACCESSORIES
Remote control
(1 unit)
Battery
BACK
(AA battery X
2 units)
When used on a tabletop
Stand
(1 unit)
Thumbscrew
(2 units)
Handle
Located on
bottom of
stand
Exhaust port
When wall mounting this product
Wall mounting
bracket 1
Wall mounting
bracket 2
Wood screw
(4 units)
Small screw
Power cord
Power plug
(2 units)
Cushions
(2 units)
E-5
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
WHEN WALL MOUNTING
CAUTION
WHEN USING THE UNIT ON A
TABLETOP
FIXING THE STAND
Remove the front panel.
• When mounting the air purifier on a wall, the
wall will become dirty as time passes.To pre-
vent this, place a vinyl sheet, etc., around the
unit.
1 • At this time, also remove the pre-filter,
stamina-power carbon and the HEPA
filter.
1
• Ensure that the wall is suitable for mounting
the air purifier.
Front panel
2
1
• Do not install in a location with heavy smoke,
such as in a kitchen, etc.The unit surface may
crack as a result.
Determine the mounting location
1 Leave space around the bracket by referring
to the illustration below. The unit cannot be
mounted if there is insufficient spacing
around the bracket.
Place the unit with its front
2 side facing down on a flat
and stable surface.
• Place a soft cloth, etc., to prevent
damaging the unit.
75cm or more
69cm or more from
the ceiling
Size of main
unit
75cm or more
75cm or more
Mounting
bracket 1
60cm or more from
sidewall
60cm or more
from sidewall
Insert the tabs on the stand
3 into the holes on the main
unit and fix the stand using
the supplied thumbscrews
(2 units).
Holes
Tabs
CAUTION
Mount on a flat sur-
face
• Do not mount the unit to
a thin wall with little
strength such as a plas-
terboard, etc. The unit
may fall and can be very
dangerous.
Thumb-
screws
E-6
Download from Www.Somanuals.com. All Manuals Search And Download.
Mount mounting bracket 2 to the
main unit
2
3
REMOVING THE UNIT
Mount the bracket to the back of the main unit
using the small screws included.
Pull the bottom of the unit towards you and then
lift.
NOTES
Mounting bracket 2
• When removing
the unit disconnect
the power cord.
Small screws
(2 units)
Place the cushions as shown
Cushions (2 units)
Mount the main unit
4(1) Align the horizontal positions of mounting
brackets 1 and 2 and hook the bracket 2 to
bracket 1.
(2) Hold the bottom
of the main unit,
pull the unit to-
wards you and
then pull down.
Check the installation
5 • Check to make sure that the tabs on mount-
ing bracket 2 are securely mounted to the
tabs on mounting bracket 1.
• Check that the power cord is not pinched.
Download from Www.Somanuals.Eco-m7. All Manuals Search And Download.
PREPARATION
Be sure to remove the power plug from the wall outlet.
INSTALLING THE FILTERS
To maintain the quality of the filters, they are installed in the main unit within polyvinyl bags.
Be sure to remove the filters from the polyvinyl bags before using the unit.
1
Remove the filters
1 Place the unit facing up
Place the unit on a table, etc., so that the
Place so stand
does not touch
the surface
stand does not touch the surface.
Soft cloth
Table, etc.
1
2 Remove the front panel
Front panel
2
Press in the hook on the bottom of the front
panel and lift to remove.
2
1
1
Hook
Prefilter
Remove the pre-filter, and
then remove the stamina-
power carbon (black) and
HEPA filter (white) that are
inside the polyvinyl bags.
3
Stamina-power carbon
INSERTING BATTERIES IN THE REMOTE CONTROL
About the batteries
Remove the
1 back cover
• The battery life is about 1 year.
Replace the batteries when the remote con-
Press and slide the
trol becomes inoperative.
• Incorrect usage of the batteries may cause
back cover to re-
move.
battery fluid leakage and/or damage. Take
caution of the following when handling:
• When replacing the batteries, replace
both batteries with new ones of the same
type. (Use AA alkaline batteries (2 units)
or AA manganese batteries (2 units).)
• When not using the unit or remote con-
trol for an extensive period, remove the
batteries.This prevents malfunction of the
remote control from battery fluid leakage.
Insert batteries
2
Insert batteries with
and
as shown
below.
Close the back
3 cover
E-8
Download from Www.Somanuals.com. All Manuals Search And Download.
Tabs
HEPA filter
2
1
Install the filter
Remove the HEPA filter from
the polyvinyl bag and install it
in the main unit with the
display facing up.
Insert so that the tabs on the HEPA filter
are facing you.
Proper operation cannot be achieved if
installed incorrectly.
Stamina-power carbon
Remove the stamina-power car-
bon from the polyvinyl bag and
install it in the main unit.
Make sure the tabs on the HEPA filter remain vis-
ible.
2
3 Install the pre-filter
Insert the 4 tabs on the pre-filter in the holes of the
main unit.
Back of front panel
Replacement label
Fill in the usage start date on
4
the replacement label affixed on
the back of the front panel and
then mount the front panel.
Use the date as a guide for the filter replacement
period.
USING THE REMOTE CONTROL
• Operate the remote control facing the main unit (re-
ceiver).
• The signal range is about 7m (front).
Receiver
• Make sure there are no objects blocking the path of the
Transmitter
signal.
• A Beep will be heard from the main unit when a signal is
received.
NOTE
• Avoid strong impact on the remote control. In addition,
do not wet the remote control or place it under direct
sunlight or near a stove, etc. Malfunction may occur.
E-9
Download from Www.Somanuals.com. All Manuals Search And Download.
For the first 30 seconds after the power plug is inserted
into the wall outlet, the unit will check the conditions of
the air. If operation is set to ON during this time, the
Clean sign lamp will alternately flash in green, orange
and red. During this time, the Cluster ion lamp will light
blue and the unit will be in the Clean mode.
OPERATION
Operations available with
main unit
MAIN UNIT OPERATION
• AUTO operation
• Silent operation
• Median level operation
• High level operation
• Max level operation
•
Tobacco smoke mode
*
operation
• Pollen mode operation
MODE-ON/OFF button
Plasmacluster
Cluster ion lamp
The unit will start operation when the MODE-ON/OFF button is pressed.
(The unit will start operation in AUTO mode)
• During operation, the cluster ion lamp will light.
(During start of operation, the cluster ion mode will be AUTO)
The operation mode suitable for the usage condition can be set.
Stop
AUTO operation
The fan level is automatically switched (High, Median, Silent) depend-
ing on the amount of pollution in the air detected by the dust sensor for
efficient air purification.
Silent operation
The unit will operate using little air.
Median ~ Max operation
The unit will operate with fan level of median, high or max.
Tobacco smoke mode operation
*
The unit will operate in High for 10 minutes, then the unit will return to
the AUTO mode.
It can not remove the noxious
substances (carbon monoxide
etc.) from cigarette smoke.
10 minutes: High fan level
AUTO mode operation
*
Pollen mode operation
The unit will operate in High for 10 minutes, then the unit will alternately
operate between Median and High.
10 minutes: High fan level
20 minutes: Median level
20 minutes: High fan level
E-10
Download from Www.Somanuals.com. All Manuals Search And Download.
Operations available with
remote control
• Fan level manual opera-
tion
• Fan level AUTO operation
• Silent operation
• Max operation
REMOTE CONTROL
OPERATION
• To start operation, press the ON/OFF button.
A short beep will sound and operation will start in the
AUTO mode.
•
Tobacco smoke mode
*
operation
• Pollen mode operation
• OFF timer setting
• Cluster ion select
AUTO cluster ion
Clean mode
• To stop operation, press the ON/OFF button again.
A long beep will sound and operation will stop.
Refresh mode
Transmitter
AUTO (fan level) but-
Manual (fan level)
ton
button
The fan speed depends upon
the amount of pollution in the
air.
The fan level can be switched
between Silent, Median, High
and Max.
Max operation button
Used to quickly clean the air in
the room.
Silent operation but-
ton
Operation will be in the Silent
mode with little air.
Pollen mode opera-
tion button
Tobacco smoke
*
The unit operates effectively
when you suspect pollen in the
air.
mode operation but-
ton
Unit will operate effectively
when smoking cigarettes, etc.
RESET
OFF timer button
Used to set the OFF timer.
The set time switches every
time the button is pressed as
shown below.
ON/OFF button
Plasmacluster
AUTO
OFF
Used to start AUTO operation
(short beep) and stop opera-
tion (long beep).
1 hour
4 hours
8 hours
Filter reset button
Press this button after replac-
ing the filters.
Cancel
AIR PURIFIER
• The remaining time is indi-
cated by the lamp as time
passes.
• The unit will stop operation
It can not remove the noxious
when the timer is up.
*
substances (carbon monoxide
At the start of operation, the
Cluster ion mode is also set
to AUTO.
etc.) from cigarette smoke.
Cluster ion select button
OFF button
AUTO cluster ion button
The generation of ions is stopped and the
cluster ion lamp is turned off.
The unit will switch between the Clean mode and
Refresh mode automatically depending on the
amount of pollution in the air detected by the dust
and odour sensor.
Refresh button
The unit will constantly operate in the Re-
fresh mode.The Refresh mode maintains
the balance of ions in the air for a refresh-
ing effect.
Clean button
The unit will constantly operate in the Clean
mode. The Clean mode is effective for removing
mold fungus in the air.
(Cluster ion lamp on (green))
(Cluster ion lamp on (blue))
If the room smells especially moldy, operate the unit in the Clean mode.
Download from Www.Somanuals.Eco-m1. 1All Manuals Search And Download.
CARE AND MAINTENANCE
(To maintain the best performance of this product, please clean the unit periodically.)
When cleaning, be sure to remove the power plug from the wall outlet. In addition, never
handle the power plug with wet hands.
Electrical shock and/or bodily injury may occur as a result.
MAIN UNIT
FILTERS
For soiling on the main unit and the installed
surface, clean as early as possible. Stubborn
dirt may be hard to remove.
Clean using the nozzle of a vacuum
cleaner without removing the pre-filter.
Dry wipe with a soft cloth
For stubborn dirt, wipe with a soft cloth damp-
ened with water or warm water of 40°C or less.
Do not use volatile fluids
Benzene, paint thinner, polishing powder, etc.,
may damage the unit surface.
Do not use detergents
Detergent ingredients may damage the unit
surface.
NOTE
Do not get wet
Never apply water on the unit.
Never wash or clean the HEPA filter or
stamina-power carbon by directly con-
tacting the nozzle of a vacuum cleaner.
This will greatly decrease the perform-
ance of the filters.
ODOR SENSOR
DUST SENSOR
The sensitivity of the sensors will become
unstable if the odor or dust sensor is dirty or
blocked.
Remove dust on the surfaces of the sensor
openings using a vacuum cleaner.
Odor sensor
Dust sensor
Download from Www.Somanuals.Eco-m1. 2All Manuals Search And Download.
GUIDE FOR LIFE OF FILTERS
• The replacement period differs depending on the usage hours and
location of installation.
• Some of the odor ingredients adsorbed by the filters become separated
and are discharged through the exhaust port as odor.
Depending on the usage environment, this odor may become strong in
several months and the exhaust port may smell.
If dust or odors cannot be removed easily, replace the filters.
(Refer to page1, FOR UNDERSTANDING THE PRODUCT)
Guide for filter replacing timing
• The following is a guide from JEM 1467 by Japan Electrical Manufacturers Association in
Japan, and in JEM 1467, the replacement period is set as when smoking 10 cigarettes per
day and the dust collection/deodorization power is reduced by half that of new filters.
• HEPA filter
About 5 years after opening
• Stamina-power carbon About 5 years after opening
• The filter timer lamp is programmed to light in about 5 years, when using the unit for 12
hours everyday, in order to indicate accumulated usage time of the guide above.
• The filter timer lamp is to be used only as a guide.
• The operation hours are kept in memory even when removing the power plug for
transportation to another room, etc.
REPLACING THE FILTERS
See page 8 “Installing the filters” for the replacement method.
1
After replacing the filters:
2
Be sure to press the Reset button on the remote control with the power plug inserted in
the wall outlet.
A short beep will be heard and the operation hours stored in the memory will be reset. If
the filter replacement lamp is on, the lamp will turn off.
Fill in the usage start date of the filters on the date label in-
3
cluded with the replacement filters. Affix the label on top of the
replacement label that is already on the back of the front panel.
Replacement filters
• HEPA filter: 1 unit
• Stamina-power carbon: 1 unit
Model: FZ-40SEF
Please ask for replacement filters at your dealer of purchase.
Cautions concerning the disposal of filters
Please dispose of replaced filters according to the local disposal laws and regulations.
HEPA filter materials:
• Filter: Polypropylene
• Frame: Polyester
Stamina-power carbon materials:
• Deodorizer: Activated charcoal
• Frame: Polyester
Download from Www.SomanualsE.co-m1.3All Manuals Search And Download.
TROUBLESHOOTING
Before calling for repair, check the symptoms below for possible remedies, since the problem may
not be a malfunction of the unit.
SYMPTOM
The remote control does not
REMEDY (not a malfunction)
• Have the batteries depleted?
• Are the batteries inserted correctly?
• Is a fluorescent lighting in the room flickering due to service
life? (Refer to E-3)
work
• Are the filters heavily soiled? (Refer to E-13)
Odors and smoke cannot be re-
moved easily
• Is the opening of the dust sensor blocked or clogged?
• Was the air already dirty when the power plug was inserted
into the wall outlet? (Refer to E-4)
The Clean sign lights green
even when the air is dirty
• The sensitivity of the sensor becomes unstable when the
opening of the dust sensor is dirty or is clogged.
Clean the dust around the sensor opening using a vacuum
cleaner. (Refer to E-12)
The Clean sign lights orange or
red even when the air is clean
The cluster ion lamp remains
green (blue) and does not
change
• During the Clean mode (or Refresh mode), the cluster ion lamp
colour will not change.
• This is the sound that is emitted when the unit is in t
Refresh mode.
h
e
A sound is
heard from the
unit
Click, click
If the sound is irritating, switch the unit to the Clean mode.
• This is the sound that is emitted when the unit is generating
cluster ions.
If the sound is irritating, such as when sleeping, etc., set the
Cluster ion mode to OFF.
Tick, tick, tick
• The ozone generated by the cluster ion generator may have
an odor. However, the density of ozone generated is very little
and is harmless to the human body. Furthermore, the ozone
decomposes quickly so it does not accumulate in the room.
The discharged air smells
The unit does not operate even
when smoking cigarettes
• Is the unit installed in a location that is difficult for the sensors
to detect cigarette smoke?
• Are the odour and dust or dust sensor openings blocked or
clogged? (In this case, clean the openings.)
(Refer to E-12)
The applicable floor surface area is the surface area for
when operating the unit in Max fan level.
(According to Japan Electrical Manufacturers’ Association
JEM1467)
SPECIFICATIONS
Power supply
220V-240V 50Hz
Fan level adjustment
Rated power
Fan level
Applicable floor surface
Cord length
Dimensions
Weight
Max
39W
High
21W
Median
10W
Silent
4W
Fan level
operation
240m3/hour 180m3/hour 117m3/hour 30m3/hour
~31m2
2.5m
415mm(W)X197mm(D)X572mm(H)(W/ stand)
6.6kg
About the reduction of standby power
In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this product
consumes about 0.8W of standby power.
(At this time, the power lamp will be on) For the conservation of energy, remove the power plug when
not using the unit
SHARP CORPORATION
OSAKA, JAPAN
TINS-A056KKRZ 02HK 1
E-14