TROUBLE SHOOTING GUIDE  
GETTING TO KNOW YOUR HAND VACUUM  
PROBLEM  
POSSIBLE REASON  
POSSIBLE SOLUTION  
1. Power cord not firmly plugged 1. Plug unit in firmly.  
HAND VACUUM  
WILL NOT  
OPERATE  
into outlet.  
2. Check fuse or breaker.  
Replace fuse/reset breaker.  
3. Call 1-800-798-7398.  
2. No power in wall outlet.  
3. Needs servicing.  
1. Allow unit to cool down, then  
Restart. Empty dust cup –  
(see page 4).  
2. Turn unit off and unplug  
from wall outlet. Remove  
Dust Cup Filter and check  
for object(s) in air duct and  
remove.  
3. Clean or replace Dust Cup  
Filter. (see page 4)  
HAND VACUUM  
1. Dust cup is full.  
WILL NOT PICK-UP 2. Unit clogged.  
OR SUCTION  
POWER IS WEAK  
3. Dust Cup Filter needs  
cleaning or replacing.  
1. Dust cup is full.  
2. Dust Cup Filter is not  
installed correctly.  
3. There is a puncture/hole in  
Dust Cup Filter.  
1. Empty dust cup.  
2. Review Dust Cup Filter  
instructions. (see page 4)  
3. Replace dust cup filter. (see  
page 4)  
DUST ESCAPING  
FROM HAND  
VACUUM  
HAND VACUUM  
HOSE OR  
BRUSHES WILL  
NOT PICK-UP  
1. Remove hose and/or  
bushes. Remove obstruction  
from hose.  
1. Hose clogged.  
2. Dust cup is full.  
2. Empty and clean dust cup.  
REPLACEMENT FILTERS  
Replacement dust cup filter SKU# AKC031  
for Model EP031KC  
Call:  
1-866-98SHARK (1-866-987-4275)  
6. Dust Cup Filter  
7. Upholstery Brush  
8. Crevice Tool  
1. Suction Hole  
Monday to Friday 8:30 A.M. - 5:00 P.M. Eastern Standard Time  
2. Dust Cup Release Button  
3. On/Off Power Switch  
4. Handle  
or  
9. Flexible Hose  
5. Dust Cup (Container)  
FOR TECHNICAL SUPPORT  
Call: 800-798-7398  
Technical Specifications  
Monday to Friday 8:30 A.M. - 5:00 P.M. Eastern Standard Time  
Voltage:  
Power:  
120V., 60Hz.  
3.75 Amps, 450 Watts  
Please Note  
The Dust Cup Filter is washable. It should, however, be replaced every three  
(3) months to ensure peak performance of your vacuum.  
Important  
Make sure that Dust Cup Filter is completely dry before re-installing back  
in the hand vacuum.  
2
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
OPERATING INSTRUCTIONS cont.  
Cleaning & Changing the  
3. To use the flexible hose, push  
3. Empty the dust from the dust cup  
Warning: Always unplug from  
electrical outlet before opening the dust  
cup (container).  
Note: Dust cup filter must be used  
when operating the hand vacuum.  
the end of the hose into the  
suction hole, then attach the  
desired accessory to the other  
end of the flexible hose, as  
shown below.  
(container). (Fig. 3)  
Dust Cup Filter  
4. Rinse the dust cup filter in cold water  
and then wait 24 hours until it dries  
completely before replacing back  
into the dust cup (container).  
(Fig. 4 & 5)  
5. When the dust cup filter is completely  
dry, replace the dust cup filter carefully  
back into the dust cup (container).  
6. Attach the dust cup (container) to the  
Hand Vacuum.  
Warning: Always unplug the unit from  
electrical outlet before opening the Dust  
Cup (container).  
Important: Do NOT use the hand  
vacuum without the dust cup filter in  
place.  
Assembling the Hand Vacuum  
1. To open the dust cup (container), push  
the dust cup release button and pull  
out the dust cup. Verify that the dust  
cup filter is inside, then attach the dust  
cup (container) to the hand vacuum.  
Warning: After each Use - Always  
remove and empty the Dust Cup Filter.  
1. To open the Dust Cup (container),  
push the dust cup release button  
and detach the Dust Cup  
(container). (Fig. 1)  
2. Remove the dust cup filter. (Fig. 2)  
Fig. 1  
How To Operate Your  
Hand Vacuum  
Fig. 3  
1. Hold the hand vacuum firmly in  
your hand by the Handle.  
2. Push the On/Off Power Button to  
“On” position.  
2. To attach the crevice tool or  
upholstery brush to the Hand  
Vacuum, push desired accessory  
into the suction hole, as shown  
below.  
3. Start vacuuming.  
CAUTION: The Hand Vacuum is a  
very powerful unit. Make sure that you  
hold it firmly, otherwise it can slip out of  
your hand and cause injury.  
Fig. 4  
Fig.2  
Fig. 5  
CAUTION: The suction hole must be  
open, free of any obstructions at all  
times. Otherwise, the motor will overheat  
and could become damaged.  
Please Note: The Dust Cup Filter is  
washable. It should, however, be  
replaced every three (3) months to  
ensure peak performance of your  
vacuum.  
Important: Make sure that Dust Cup  
Filter is completely dry before re-  
installing back in the hand vacuum.  
3
4
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sharp Computer Monitor TINSE1166MPZZ User Manual
SIIG Network Card 04 0638E User Manual
Silvercrest Headphones KH2349 User Manual
Sony Car Stereo System 757MX User Manual
Sony CRT Television KV HF21M80 User Manual
Sony DJ Equipment DPS V77 User Manual
Sony Ericsson Camera Accessories SAL1855 User Manual
Star Micronics Printer TSP700II User Manual
Sunbeam Bread Maker PM4210 User Manual
Tandberg Data Cassette Player VXA 320 VXA 3 User Manual