Information on this quick guide  
Information on this quick guide  
Please make sure to read the “Safety information” supplement included separately  
with the product. This supplement contains important information on the safe  
operation of the product as well as the manufacturer’s declaration and warranty  
notes.  
A detailed instruction manual for the overall ADN conference system can be found  
www  
Manual  
on the DVD-ROM supplied with the ADN CU1 central unit.  
The ADN PS power supply  
The ADN PS power supply is part of the Sennheiser ADN conference system.  
For large conference systems with up to 400 conference units, you require ADN PS  
power supplies. A max. of 15 ADN PS power supplies can be used in a conference  
system. When the conference units are connected in simple strings, one ADN PS  
power supply can power up to 70 conference units. When the conference units are  
connected in ring topology, one ADN PS power supply can power a max. of  
40 conference units.  
ADN CU1  
Conferences with up to a max. of 400 participants  
ADN PS  
ADN PS  
max. 15 ADN PS  
max. 400 ADN D1/  
ADN C1  
per ADN PS with  
per ADN PS with  
standard cabling a  
redundant ring cabling a  
max.of 70 ADN D1/ADN C1  
max. of 40 ADN D1/ADN C1  
Delivery includes  
1
1
1
1
ADN PS power supply with premounted rack mount “ears”  
mains cable (EU, UK or US version), length 1.8 m  
quick guide  
“Safety information” supplement  
2 | ADN PS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Delivery includes  
Components required for operation  
Central unit/  
Power supplies  
Number  
Description  
Cat. No. Function  
1
ADN CU1-EU central unit, 505553 Controls the conference and  
EU version  
supplies power to max. of  
40 conference units  
ADN CU1-UK central unit, 505554  
UK version  
ADN CU1-US central unit, 505555  
US version  
1 –15  
ADN PS-EU power supply, 505546 Supplies power to conference  
EU version  
units connected in simple  
strings or in redundant ring  
topology,  
for conferences with up to  
400 conference units  
(optional)  
ADN PS-UK power supply, 505547  
UK version  
ADN PS-US power supply, 505548  
US version  
Conference units  
Number  
Description  
Cat. No. Function  
Max. 400 ADN D1 delegate unit  
502758 Allows to make contributions  
to the conference  
1 – 10  
(optional)  
ADN C1 chairperson unit 502759 Allows to manage the  
conference  
System cables  
The system cables are black and have two shielded RJ45 plugs.  
Number  
Description, length  
Cat. No. Function  
Divers  
SDC CBL RJ45-2, 2 m  
SDC CBL RJ45-3, 3 m  
SDC CBL RJ45-5, 5 m  
SDC CBL RJ45-10, 10 m  
SDC CBL RJ45-20, 20 m  
SDC CBL RJ45-50, 50 m  
009842 Allow to interconnect  
components and conference  
009843  
units  
009844  
009845  
009846  
009847  
Additional accessories for the ADN conference system can be found at  
ADN PS | 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product overview ADN PS power supply  
Product overview ADN PS power supply  
1
2
3
4
5
1
ADN PS  
PORT  
I
PORT II  
DATA  
/S  
S  
1
2
1
2
100 20V  
-
50/60H385W  
PORT  
I
&
PORT II: max. 5.25A sum  
C
B
6
7
8
9
0
A
D
E
15  
A Front view  
B Rear view  
1
2
3
6
7
8
9
<
Rack mount “ears”  
On/off switch  
PORT I socket – output 1 (RJ45) for  
connection of conference units  
PORT I socket – output 2 (RJ45) for  
connection of conference units  
PORT I status LED for  
outputs 1 and 2  
PORT II socket – output 1 (RJ45) for  
connection of conference units  
4
5
PORT II status LED for  
outputs 1 and 2  
PORT II socket – output 2 (RJ45) for  
connection of conference units  
POWER status LED  
DATA CU/PS input socket (RJ45) for  
connection of ADN CU1 central unit or  
ADN PS power supply  
A
DATA PS output socket (RJ45) for  
connection of additional ADN PS  
B
C
D
E
Fans  
Mains socket  
Hazard warnings  
Type plate  
Overview of the status LEDs  
Status LED Color  
Meaning  
5
POWER  
green  
ADN PS is switched on  
Not used, switched off  
3
PORT I /Port II  
output 1/2  
4
orange Conference units are connected in strings  
green Conference units are connected in redundant  
ring topology via outputs 1 and 2  
flashing Error in a cable string;  
orange output is switched off  
4 | ADN PS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Structuring and controlling the conference system  
Structuring and controlling the  
conference system  
Structuring the conference system  
The ADN conference system is suitable for conferences with up to 400 conference  
units. For safe operation of the conference system, make sure that all conference  
units are supplied with a voltage of at least 35 V! The voltage supplied depends on  
the number of connected conference units and on the cable lengths. The standard  
cable length between the central unit or power supply and the first conference unit  
is 80 m max. and the standard cable length between the individual conference  
units is 2 to 5 m.  
If these cable lengths are observed, safe operation of conference systems with the  
following number of conference units is ensured:  
small conference systems comprising only an ADN CU1 central unit  
– 30-40 conference units connected in simple strings  
large conference systems comprising an ADN CU1 central unit and a max. of  
15 ADN PS power supplies  
– max. 400 conference units connected in simple strings or in ring topology  
per ADN PS power supply  
– 60-70 conference units connected in simple strings  
– 30-40 conference units connected in ring topology  
If cable lengths are shorter, it might be that more conference units can be used.  
ADN D1 delegate units and ADN C1 chairperson units can be combined in an  
arbitrary order. The number of chairperson units, however, is limited to 10 max. per  
conference system. All components of the conference system are interconnected  
using SDC CBL RJ-45 system cables.  
Small conference system with simple cabling  
For small conference systems with approx. 30-40 conference units, you require one  
ADN CU1 central unit for controlling the conference. The conference units are  
interconnected in two cable strings which are directly connected to the central unit.  
ADN CU1  
max. 40  
ADN D1/ADN C1  
ADN CU1  
1
2
3
...  
20  
max. 80 m  
approx.. 2-5 m approx.. 2-5 m  
52.8 V  
>35 V  
ADN PS | 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Structuring and controlling the conference system  
Large conference system with simple cabling  
For setting up a large conference system with the maximum number of conference  
units (i.e. up to 400), you require one ADN CU1 central unit for controlling the  
conference and additional ADN PS power supplies for powering the conference  
units. The conference units are interconnected in cable strings and up to four cable  
strings can be connected to each ADN PS power supply.  
ADN CU1  
ADN PS (max. 15)  
max. 70  
ADN D1/ADN C1  
ADN CU1  
ADN PS  
...  
1
2
3
20  
max. 80 m  
max. 80 m  
approx. 2-5 m approx. 2-5 m  
52.8 V  
>35 V  
6 | ADN PS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Structuring and controlling the conference system  
Large conference system with redundant ring topology  
The redundant ring topology ensures that, should one conference unit or system  
cable fail or be manipulated, all other conference units of the cable ring will  
continue to function reliably.  
For setting up a large conference system with redundant ring topology, you require  
one ADN CU1 central unit for controlling the conference and additional ADN PS  
power supplies for powering the conference units. The conference units are  
interconnected in rings and two rings can be connected to each ADN PS power  
supply.  
ADN CU1  
ADN PS (max. 15)  
max. 40  
ADN D1/ADN C1  
ADN CU1  
ADN PS  
1
2
3
... 20  
max. 80 m  
max. 80 m  
approx. 2-5 m approx. 2-5 m  
52.8 V  
>35 V  
Calculating the voltage supply of the conference units  
The “ADN Cable Calculator” software allows you to calculate the voltage supply on  
the individual sections of a cable string or cable ring and to plan the structure of  
the conference system. The software is available from your Sennheiser partner or  
For further information on the installation and use of the “ADN Cable Calculator”  
software, refer to the help section of the “ADN Cable Calculator” software and to  
the detailed instruction manual “ADN Conference System”.  
ADN PS | 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preparing the ADN PS power supply for use  
Preparing the ADN PS power supply  
for use  
Setting up the power supply  
CAUTION  
Danger of material damage and personal injury due to stacked  
power supplies!  
When stacking several ADN PS power supplies on top of each other,  
the stack may topple over,  
the temperature of the individual ADN PS power supplies may  
drastically increase,  
high mechanical loading may be exerted on e.g. the housings,  
cables or installation surfaces.  
This can cause material damage and personal injury.  
̈ Never stack several ADN PS power supplies on top of each other.  
̈ Make sure that the air vents are not covered or blocked.  
̈ Place the ADN PS power supply on a flat surface as shown.  
IFor information on how to mount the power supply into a 19” rack, refer to  
the detailed instruction manual “ADN Conference System”.  
Connecting the ADN PS power supply to the mains power supply  
CAUTION  
Product damage due to unsuitable mains cables or power outlets!  
An unsuitable power supply can damage the product.  
̈ Use the mains cable (supplied) for connecting the product to the mains power  
supply.  
̈ Only use multi-outlet power strips or extension cables with protective ground  
contacts.  
̈ Only use mains cables with a 3-pin connector.  
C
̈ First connect the mains cable (supplied) to the mains socket  
.
̈ Connect the mains cable to the mains power supply.  
The ADN PS power supply is now ready for operation.  
15  
100  
-
240V  
50/60Hz 385W  
C
8 | ADN PS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting up the conference system  
Setting up the conference system  
CAUTION  
Product damage due to an unsuitable power supply!  
If you connect standard network devices with RJ45 plugs (e.g. switches or network  
cards) to the connection sockets PORT I and PORT II, the network devices can be  
damaged due to an unsuitable power supply.  
̈ Only connect ADN C1 and ADN D1 conference units to the connection sockets  
PORT I and PORT II.  
Basic information on the set-up of the conference system  
Regardless of the number of conference units and the room size, we recommend  
the following procedure for setting up the conference system:  
̈ Plan the number of conference units required for your conference system.  
A total of 400 conference units can be used in a conference system (the  
number of ADN C1 chairperson units is limited to 10 max.). Always take the  
largest possible number of participants as a starting point.  
̈ Plan if simple cabling is sufficient or if you require a redundant ring topology  
(see page 5).  
̈ If necessary, calculate the number of ADN PS power supplies required (a max.  
of 15 ADN PS power supplies can be used in a conference system).  
̈ If necessary, calculate the maximum length of the cabling in order to ensure  
that all conference units connected are supplied with sufficient voltage  
(see page 7).  
̈ Place the ADN CU1 central unit and, if necessary, the ADN PS power supplies in  
the electrical equipment room.  
̈ Place the conference units at the corresponding seats.  
̈ Put out a sufficient number of SDC CBL RJ45 system cables in the required  
lengths.  
Setting up a small conference system with only the central unit  
For a small conference system, you do not require ADN PS power supplies. The  
conference units can be directly connected to the ADN CU1 central unit (refer to the  
quick guide of the ADN CU1 central unit or to the detailed instruction manual “ADN  
Conference System”).  
ADN PS | 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting up the conference system  
Connecting ADN PS power supplies to the ADN CU1 central unit  
For conference systems comprising more than 40 conference units or when the  
conference units are connected in a redundant ring topology, you require ADN PS  
power supplies. A max. of 15 ADN PS power supplies can be used in a conference  
system.  
8
9
̈ Use a system cable to connect the PORT II socket  
or PORT I socket  
of the  
<
ADN CU1 central unit to the DATA CU/PS input socket  
of the first ADN PS  
power supply (shorter cables increase the operational reliability, the maximum  
length allowed is 80 m).  
A
̈ Use a system cable to connect the DATA PS output socket of the first ADN PS  
<
power supply to the DATA CU/PS input socket  
supply.  
of the second ADN PS power  
̈ Repeat these steps for the remaining ADN PS power supplies.  
ADN CU1  
ADN PS  
IN –– AUDIO –– OUT  
PORT  
I
PORT II  
DATA  
CU/PS  
PS  
PORT II PORT  
I
1
2
1
2
100-240V~  
50/60Hz 240W  
100  
50/60Hz 385W  
-
240V  
2x 52.8V  
1.75A  
PORT  
I
&
PORT II: max. 5.25A sum  
8
9
<
A
DATA  
DATA  
CU/PS PS  
DATA  
CU/PS PS  
PORT II PORT I  
CU/PS PS  
Setting up a large conference system comprising ADN PS power supplies and  
conference units connected in cable strings  
For large conference systems with up to 400 conference units, you require ADN PS  
power supplies. When the conference units are connected in simple strings, one  
ADN PS power supply can power approx. 60-70 conference units.  
Connecting conference units  
connected in a cable string to the  
ADN PS power supply  
The following describes how to connect one cable string to an ADN PS power  
supply. If necessary, repeat these steps for additional cable strings and additional  
ADN PS power supplies.  
̈ Connect the required number of ADN PS power supplies to the ADN CU1 central  
unit (see above).  
6 8  
or  
̈ Use a system cable to connect the PORT I or PORT II socket – output 1  
7 9  
of the first  
/
µ
2
/
– of the ADN PS power supply to the IN socket  
conference unit.  
¸
̈ Use a system cable to connect the OUT socket of the first conference unit to  
µ
the IN socket  
of the second conference unit.  
̈ Repeat these steps for additional conference units.  
̈ If necessary, repeat all steps for a second, third and fourth cable string and  
additional ADN PS power supplies.  
10 | ADN PS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting up the conference system  
ADN PS  
ADN D1/ADN C1  
PORT  
I
PORT II  
DATA  
CU/PS  
PS  
1
2
1
2
100  
-
240V  
50/60Hz 385W  
PORT  
I
&
PORT II: max. 5.25A sum  
µ
¸
6 7 8 9  
PORT I PORT II  
IN OUT  
IN OUT  
IN OUT  
1
2
1
2
ADN CU1  
ADN PS  
ADN PS  
PORT I  
1
IN  
IN  
OUT  
...  
OUT  
OUT  
20  
20  
1
PORT I  
2
IN  
IN  
OUT  
IN  
IN  
OUT  
1
1
...  
20  
20  
PORT II  
1
IN  
IN  
OUT  
1
...  
PORT II  
2
OUT  
OUT  
...  
PORT I  
1
IN  
IN  
OUT  
...  
OUT  
OUT  
20  
20  
1
1
PORT I  
2
IN  
IN  
OUT  
IN  
IN  
OUT  
1
...  
20  
20  
PORT II  
1
IN  
IN  
OUT  
...  
PORT II  
2
OUT  
OUT  
1
...  
Please note that there is a limited number of approx. 15-20 conference  
units per cable string due to the voltage drop on the cable string  
(see page 5).  
One ADN PS power supply can power a total of 60-70 conference units if all  
connection sockets (PORT I and PORT II/outputs 1 and 2) are used.  
You can use optional cable holders for guiding the system cables. For  
further information, refer to the detailed instruction manual “ADN  
Conference System”.  
ADN PS | 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting up the conference system  
Setting up large conference system comprising ADN PS power supplies  
conference units connected in redundant ring topology  
In large conference systems with up to 400 conference units, the redundant ring  
topology ensures that, should one conference unit or system cable fail or be  
manipulated, all other conference units of the cable ring will continue to function  
reliably. When the conference units are connected in ring topology, one ADN PS  
power supply can power approx. 30-40 conference units.  
To ensure full operational reliability in a redundant ring topology, the  
hardware of the ADN C1 and ADN D1 has been revised. If you combine  
conference units with hardware revision 1 (no marking on the type plate)  
and conference units with hardware revision 2 (“HW: v2” is printed on the  
type plate), fail-safe operation is only possible to a limited extent.  
̈ In a redundant ring topology, only use conference units with hardware  
revision 2.  
T
U
IN  
O
Connecting conference units  
connected in a cable ring to the  
ADN PS power supply  
The following describes how to connect one cable ring to an ADN PS power supply.  
If necessary, repeat these steps for a second cable ring and additional ADN PS  
power supplies.  
̈ Connect the required number of ADN PS power supplies to the ADN CU1 central  
unit (see page 10).  
6
̈ Use a system cable to connect output 1  
of the PORT I socket of the ADN PS  
µ
power supply to the IN socket  
of the first conference unit.  
¸
̈ Use a system cable to connect the OUT socket of the first conference unit to  
µ
the IN socket  
of the second conference unit.  
̈ Repeat these steps for additional conference units.  
¸
̈ Use a system cable to connect the OUT socket  
of the last conference unit in  
7
the cable ring to output 2  
of the PORT I socket of the ADN PS power supply.  
̈ If necessary, repeat all steps for a second cable ring on PORT II and the  
additional ADN PS power supplies.  
12 | ADN PS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting up the conference system  
ADN PS  
ADN D1/ADN C1  
PORT  
I
PORT II  
DATA  
CU/PS  
PS  
1
2
1
2
100 240V  
-
50/60Hz 385W  
PORT  
I
&
PORT II: max. 5.25A sum  
µ
¸
6 7 8 9  
PORT I PORT II  
IN OUT  
IN OUT  
IN OUT  
1
2
1
2
ADN CU1  
ADN PS  
ADN PS  
PORT I  
PORT II  
PORT I  
PORT II  
1
2
1
2
1
2
1
2
IN  
IN  
IN  
IN  
1
1
1
1
OUT  
... 20  
IN  
OUT  
OUT  
OUT  
OUT  
OUT  
OUT  
OUT  
... 20  
IN  
... 20  
IN  
... 20  
IN  
Please note that there is a limited number of approx. 15-20 conference  
units per cable string due to the voltage drop on the cable string (see  
page 5).  
You can use optional cable holders for guiding the system cables. For  
further information, refer to the detailed instruction manual “ADN  
Conference System”.  
ADN PS | 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Switching the ADN PS power supply on/off  
Switching the ADN PS power supply  
on/off  
The ADN PS power supplies can only be switched on when the central unit  
and the previous ADN PS connected in series are also switched on.  
You can set up your conference system so that you can increase or reduce  
the number of conference units used by simply switching individual ADN PS  
on or off.  
ADN CU1  
ADN PS  
ADN PS  
ADN PS  
ADN PS  
ESC  
ON  
ON  
ON  
OFF  
OFF  
ADN CU1  
ADN PS  
ADN PS  
ADN PS  
ADN PS  
ESC  
OFF  
ON  
ON  
ON  
ON  
Switching the conference system on  
̈ On the ADN CU1 central unit and the ADN PS power supplies, set the on/off  
ADN CU1  
1
2
switch  
or  
to position “I”.  
ESC  
The central unit switches on and its display panel lights up. The power supplies  
switch on and their status LEDs light up:  
Status LED  
Color  
green  
Meaning  
1
5
POWER  
ADN PS is switched on  
Not used, switched off  
3
PORT I /Port II  
output 1/2  
4
ADN PS  
orange Conference units are connected in strings  
green  
Conference units are connected in  
redundant ring topology via output 1  
and 2  
3
4
2
5
flashing Error in a cable string;  
orange output is switched off  
Switching the conference system off  
1
̈ Set the on/off switch  
of the ADN CU1 central unit to position “0”.  
The central unit is switched off and the display panel goes off. All ADN PS power  
supplies connected to the central unit and switched on are switched off and the  
status LEDs go off.  
To switch individual ADN PS power supplies off:  
2
̈ Set the on/off switch  
of the ADN PS power supply to position “0”.  
The power supply is switched off and all status LEDs go off. Additional  
connected ADN PS power supplies are also switched off.  
To completely switch the ADN CU1 central unit or the ADN PS power supply off:  
̈ Disconnect the mains connector of the ADN CU1 central unit or the mains  
connector of the ADN PS power supply from the mains power supply.  
14 | ADN PS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cleaning and maintaining the conference system  
Cleaning and maintaining the  
conference system  
CAUTION  
Liquids can damage the product!  
Liquids entering the product can cause a short-circuit in the electronics or damage  
the mechanics.  
Solvents or cleansing agents can damage the surfaces of the product.  
̈ Keep all liquids away from the product.  
̈ Do not use any solvents or cleansing agents.  
̈ Switch the conference system off (see page 14).  
̈ Before cleaning, disconnect the ADN CU1 central unit and the ADN PS power  
supplies from the mains power supply.  
̈ Only use a dry and soft cloth to clean the product.  
To ensure optimum cooling of the ADN CU1 central unit and the ADN PS power  
supplies:  
̈ Clean the air vents on the front, back and bottom from time to time with a soft  
brush or paintbrush in order to avoid dust deposits.  
ADN CU1  
ADN PS  
ADN PS | 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications ADN PS  
Specifications ADN PS  
Dimensions  
482.5 x 168 x 100 mm (B x H x D)  
Weight  
approx. 4.6 kg  
100 to 240 V~  
50 to 60 Hz  
385 W  
Nominal input voltage  
Mains frequency  
Power consumption  
Output voltage at RJ45  
PORT I/II output 1/2  
52.8 V  
Nominal output current at  
RJ45 PORT I/II output 1/2  
max. 5.25 A in total  
max. 1.75 A per output  
Output voltage at RJ45 DATA  
52.8 V  
Nominal output current at  
RJ45 DATA  
max. 0.08 A  
Temperature range  
operation: +5°C to +50°C  
storage: 25°C to +70°C  
Relative humidity  
operation: 10 to 80%  
storage: 10 to 90%  
16 | ADN PS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Publ. 09/11  
543374/A01  
Sennheiser electronic GmbH & Co. KG  
Am Labor 1, 30900 Wedemark, Germany  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sierra Products Stove EF 4001B User Manual
Sonance Speaker 20 LCR User Manual
Sony Kitchen Entertainment Center VGN C200 User Manual
Sony Stereo Amplifier TA DA9000ES User Manual
SOYO Computer Drive Lite Motherboard User Manual
Star Manufacturing Fryer 615FD User Manual
Star Micronics Printer NX 2450 User Manual
Sunbeam Mixer SM6100 User Manual
Sungale Tablet ID430WTA User Manual
Tapco DJ Equipment MIX10FXP User Manual