SUPER MICRO Computer Computer Hardware X9DRD iF User Manual

X9DRD-iF  
X9DRD-LF  
USER’S MANUAL  
Revision 1.1a  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
Preface  
This manual is written for system integrators, PC technicians and  
knowledgeable PC users. It provides information for the installation and use of the  
X9DRD-iF/LF motherboard.  
About This Motherboard  
The Super X9DRD-iF/LF motherboard supports dual Intel E5-2600(v2) Series Pro-  
cessors (Socket R LGA 2011) that offer QPI (Intel QuickPath Interface) Technology  
(V.1.1), providing point-to-point connection with a transfer speed of up to 8.0 TG/s.  
With the C602 built in, the X9DRD-iF/LF motherboard supports Intel® Management  
Engine (ME), Rapid Storage Technology, Digital Media Interface (DMI), PCI-E Gen.  
3.0 and up to 1866 MHz DDR3 memory. This motherboard is ideal for 2U high-end  
server platforms. Please refer to our website (http://www.supermicro.com) for CPU  
and memory support updates.  
Manual Organization  
Chapter 1 describes the features, specifications and performance of the mother-  
board. It also provides detailed information about the Intel C602 chipset.  
Chapter 2 provides hardware installation instructions. Read this chapter when in-  
stalling the processor, memory modules and other hardware components into the  
system. If you encounter any problems, see Chapter 3, which describes trouble-  
shooting procedures for video, memory, and system setup stored in CMOS.  
Chapter 4 includes an introduction to BIOS, and provides detailed information on  
running the CMOS Setup utility.  
Appendix A provides BIOS Error Beep Codes.  
Appendix B lists Software Installation Instructions.  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Conventions Used in the Manual  
Pay special attention to the following symbols for proper system installation and to  
prevent damage to the system or injury to yourself:  
Warning: Important information given to ensure proper system installation or to prevent  
damage to the components  
Note: Additional information given to differentiate between various models  
or provides information for correct system setup.  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
Contacting Supermicro  
Headquarters  
Address:  
Super Micro Computer, Inc.  
980 Rock Ave.  
San Jose, CA 95131 U.S.A.  
+1 (408) 503-8000  
Tel:  
Fax:  
Email:  
+1 (408) 503-8008  
[email protected] (General Information)  
[email protected] (Technical Support)  
www.supermicro.com  
Web Site:  
Europe  
Address:  
Super Micro Computer B.V.  
Het Sterrenbeeld 28, 5215 ML  
's-Hertogenbosch, The Netherlands  
+31 (0) 73-6400390  
Tel:  
Fax:  
Email:  
+31 (0) 73-6416525  
[email protected] (General Information)  
[email protected] (Technical Support)  
[email protected] (Customer Support)  
Asia-Pacific  
Address:  
Super Micro Computer, Inc.  
3F, No. 150, Jian 1st Rd.  
Zhonghe Dist., New Taipei City 23511  
Taiwan (R.O.C)  
Tel:  
+886-(2) 8226-3990  
Fax:  
+886-(2) 8226-3992  
Web Site:  
www.supermicro.com.tw  
Technical Support:  
Email:  
Tel:  
+886-(2)-8226-3990  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Table of Contents  
Preface  
Chapter 1 Overview  
1-1  
1-2  
1-3  
1-4  
1-5  
1-6  
1-7  
1-8  
Overview ......................................................................................................... 1-1  
Processor and Chipset Overview...................................................................1-11  
Special Features ........................................................................................... 1-12  
PC Health Monitoring.................................................................................... 1-12  
ACPI Features............................................................................................... 1-13  
Power Supply................................................................................................ 1-13  
Super I/O....................................................................................................... 1-14  
Advanced Power Management..................................................................... 1-14  
Intel® Intelligent Power Node Manager (NM) (Available when the NMView  
utility is installed in the system).................................................................... 1-14  
Management Engine (ME)............................................................................ 1-14  
Overview of the Nuvoton WPCM450 Controller ........................................... 1-15  
Other Features Supported by the WPCM BMC Controller........................... 1-15  
1-9  
Chapter 2 Installation  
2-1  
2-2  
2-3  
Standardized Warning Statements ................................................................. 2-1  
Battery Handling.............................................................................................. 2-1  
Product Disposal............................................................................................. 2-3  
Static-Sensitive Devices.................................................................................. 2-4  
Precautions ..................................................................................................... 2-4  
Unpacking ....................................................................................................... 2-4  
Processor and Heatsink Installation................................................................ 2-5  
Installing the LGA2011 Processor ................................................................. 2-5  
Installing a Passive CPU Heatsink ................................................................. 2-9  
Removing the Heatsink................................................................................. 2-10  
Installing and Removing the Memory Modules..............................................2-11  
Installing & Removing DIMMs........................................................................2-11  
Removing Memory Modules ..........................................................................2-11  
Motherboard Installation................................................................................ 2-16  
Tools Needed ................................................................................................ 2-16  
Location of Mounting Holes .......................................................................... 2-16  
An Important Note on PCI-E Slot Population ............................................... 2-16  
Installing the Motherboard ............................................................................ 2-17  
Control Panel Connectors and I/O Ports ...................................................... 2-18  
Back Panel Connectors and I/O Ports.......................................................... 2-18  
Back Panel I/O Port Locations and Definitions ........................................... 2-18  
2-4  
2-5  
2-6  
vi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Serial Ports............................................................................................... 2-19  
Video Connection..................................................................................... 2-19  
Universal Serial Bus (USB)...................................................................... 2-20  
Ethernet Ports .......................................................................................... 2-21  
Unit Identifier Switch/UID LED Indicators ................................................ 2-22  
Front Control Panel....................................................................................... 2-23  
Front Control Panel Pin Definitions............................................................... 2-24  
NMI Button ............................................................................................... 2-24  
Power LED .............................................................................................. 2-24  
HDD LED.................................................................................................. 2-25  
NIC1/NIC2 LED Indicators ....................................................................... 2-25  
Overheat (OH)/Fan Fail/PWR Fail/UID LED............................................ 2-26  
Power Fail LED ........................................................................................ 2-26  
Reset Button ........................................................................................... 2-27  
Power Button ........................................................................................... 2-27  
Connecting Cables........................................................................................ 2-28  
Power Connectors ................................................................................... 2-28  
Fan Headers............................................................................................. 2-29  
Chassis Intrusion ..................................................................................... 2-29  
Internal Speaker....................................................................................... 2-30  
Power LED/Speaker................................................................................. 2-30  
TPM Header/Port 80 ................................................................................ 2-31  
Overheat LED/Fan Fail ............................................................................ 2-31  
Power SMB (I2C) Connector .................................................................... 2-32  
IPMB......................................................................................................... 2-32  
T-SGPIO 1/2 & 3-SGPIO 1 Headers........................................................ 2-33  
DOM Power Connector............................................................................ 2-33  
Standby Power Header............................................................................ 2-34  
Jumper Settings ............................................................................................ 2-35  
Explanation of Jumpers ................................................................................ 2-35  
GLAN Enable/Disable .............................................................................. 2-35  
CMOS Clear............................................................................................. 2-36  
Watch Dog Enable/Disable ...................................................................... 2-36  
VGA Enable.............................................................................................. 2-37  
BMC Enable ............................................................................................ 2-37  
Management Engine (ME) Recovery ...................................................... 2-38  
Management Engine (ME) Recovery ...................................................... 2-38  
Manufacture Mode Select ........................................................................ 2-38  
I2C Bus to PCI-Exp. Slots ........................................................................ 2-39  
2-7  
2-8  
vii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
2-9  
Onboard LED Indicators ............................................................................... 2-40  
GLAN LEDs.............................................................................................. 2-40  
IPMI Dedicated LAN LEDs....................................................................... 2-40  
Onboard Power LED ............................................................................... 2-41  
BMC Heartbeat LED ................................................................................ 2-41  
2-10 SATA/SCU Connections................................................................................ 2-42  
SATA Ports/SCU Connectors ................................................................... 2-42  
Chapter 3 Troubleshooting  
3-1  
3-2  
3-3  
3-4  
3-5  
Troubleshooting Procedures ........................................................................... 3-1  
Technical Support Procedures........................................................................ 3-5  
Battery Removal and Installation.................................................................... 3-6  
Frequently Asked Questions........................................................................... 3-7  
Returning Merchandise for Service................................................................. 3-8  
Chapter 4 BIOS  
4-1  
4-2  
4-3  
4-4  
4-5  
4-6  
4-7  
4-8  
Introduction...................................................................................................... 4-1  
Main Setup...................................................................................................... 4-2  
Advanced Setup Configurations...................................................................... 4-4  
Event Logs....................................................................................................4-24  
IPMI...............................................................................................................4-26  
Boot...............................................................................................................4-28  
Security.........................................................................................................4-29  
Save & Exit ...................................................................................................4-30  
Appendix A BIOS Error Beep Codes  
A-1  
BIOS Error Beep Codes .................................................................................A-1  
Appendix B Software Installation Instructions  
B-1  
Installing Software Programs..........................................................................B-1  
B-2  
Configuring SuperDoctor® III..........................................................................B-2  
viii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1: Overview  
Chapter 1  
Overview  
1-1 Overview  
Checklist  
Congratulations on purchasing your computer motherboard from an acknowledged  
leader in the industry. Supermicro boards are designed with the utmost attention to  
detail to provide you with the highest standards in quality and performance.  
Please check that the following items have all been included with your motherboard.  
If anything listed here is damaged or missing, contact your retailer.  
The following items are included in the retail box.  
One (1) Supermicro Mainboard  
Four (4) Serial ATA cables (CBL-0044L) (X9DRD-iF)  
Two (2) Serial ATA cables (CBL-0044L) (X9DRD-LF)  
One (1) I/O Shield (MCP-260-00042-0N)  
One (1) Quick Reference Guide (MNL-1312-QRG) (X9DRD-iF)  
One (1) Quick Reference Guide (MNL-1488-QRG) (X9DRD-LF)  
Note: For your system to work properly, please follow the links below to  
download all necessary drivers/utilities and the user's manual for your  
motherboard.  
SMCI product manuals: http://www.supermicro.com/support/manuals/  
Product Drivers and utilities: ftp://ftp.supermicro.com/  
If you have any questions, please contact our support team at support@supermicro.  
com.  
1-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
X9DRD-iF Motherboard Image  
Note: All graphics shown in this manual were based upon the latest PCB  
revision of the X9DRD-iF available at the time of publishing of the manual.  
The motherboard you've received may or may not look exactly the same  
as the graphics shown in this manual.  
1-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1: Overview  
X9DRD-iF Motherboard Layout  
USB2/3  
USB0/1  
COM2  
JUIDB  
COM1  
VGA  
USB6  
BMC  
FAN7  
LAN2  
LAN1  
FAN8  
JPG1  
JPB1  
LAN CTRL  
IPMI_LAN  
LAN  
CTRL  
SP1  
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
JBT1  
CPU2  
BIOS  
B1  
A1  
D1  
C1  
CPU1  
JBAT1  
JOH1  
:OH LED  
LED2  
JPW5  
FAN4  
JVR1  
Note 1: For the latest CPU/Memory updates, please refer to our website  
at http://www.supermicro.com/products/motherboard/ for details.  
Note 2: Changing BMC log-in information is recommended during initial  
system power-on. The default username is ADMIN and password is  
ADMIN. For BMC best practices, please refer to: http://www.supermicro.  
com/products/nfo/files/IPMI/Best_Practices_BMC_Security.pdf  
1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
X9DRD-iF Quick Reference  
USB2/3  
USB0/1  
COM2  
JUIDB  
COM1  
VGA  
USB6  
BMC  
FAN7  
LAN2  
LAN1  
FAN8  
JPG1  
JPB1  
LAN CTRL  
IPMI_LAN  
LAN  
CTRL  
SP1  
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
JBT1  
CPU2  
BIOS  
B1  
A1  
D1  
C1  
CPU1  
JBAT1  
JOH1  
:OH LED  
LED2  
JPW5  
FAN4  
JVR1  
Notes:  
See Chapter 2 for detailed information on jumpers, I/O ports and JF1 front panel  
connections. " " indicates the location of "Pin 1".  
Jumpers/LED Indicators not indicated are for testing only. Also, components that  
are not documented in this manual are reserved for internal use only.  
Use only the correct type of onboard CMOS battery as specified by the  
manufacturer. Do not install the onboard battery upside down to avoid possible  
explosion.  
1-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1: Overview  
X9DRD-iF/LF Jumpers  
Description  
Jumper  
Default Setting  
JBT1  
Clear CMOS  
See Chapter 2  
JI2C1/JI2C2  
SMB to PCI-E Slots  
BMC Enabled  
Off (Disabled)  
JPB1  
Pins 1-2 (Enabled)  
Pins 1-2 (Enabled)  
Pins 1-2 (Enabled)  
Pins 1-2 (Normal)  
JPG1  
VGA Enabled  
JPL1  
GLAN1/GLAN2 Enable  
JPME1  
Management Engine (ME)  
Recovery Mode Enable  
JPME2 (X9DRD-iF)  
JWD1  
Management Engine (ME)  
Manufacture Mode Select  
Pins 1-2 (Normal)  
Pins 1-2 (Reset)  
Watch Dog Timer Enable  
Connectors  
Connectors  
Description  
COM1/COM2  
Backplane COM Port1/Front Accessible COM2 Header  
(COM1 only: X9DRD-LF)  
(COM1/COM2: X9DRD-iF)  
FAN1~8  
CPU/System Fan Headers  
(FAN1~6: X9DRD-LF)  
(FAN1~8: X9DRD-iF)  
I-SATA 0~5 (X9DRD-iF)  
I-SATA 0~1 (X9DRD-LF)  
Four SATA 2.0 and Two SATA 3.0 Connectors from AHCI  
Two SATA 3.0 Connectors from AHCI  
JBAT1  
Onboard Battery (See Chpt. 3 for Used Battery Disposal)  
Speaker/Power LED Indicator  
JD1  
JF1  
Front Panel Control Header  
JIPMB1 (X9DRD-iF)  
JL1 (X9DRD-iF)  
JOH1 (X9DRD-iF)  
JPI2C1  
4-pin External BMC I2C Header (for an IPMI Card)  
Chassis Intrusion  
Overheat LED Indicator  
Power Supply SMBbus I2C Header  
JPW1  
24-Pin ATX Main Power Connector (Warning on Pg. 1-6.)  
12V 8-Pin Power Connectors (See Warning on Pg. 1-6.)  
12V 4-Pin Power Connectors (See Warning on Pg. 1-6.)  
SATA DOM (Device on Module) Power Connector  
+5V Standby Power Header  
JPW2/3  
JPW4/5  
JSD1 (X9DRD-iF)  
JSTBY1 (X9DRD-iF)  
JTPM1  
TPM (Trusted Platform Module)/Port 80  
Note: PCI-E slots support Low-Profile MD2 form factor for devices/add-on  
cards that are shorter than 167.64mm or 6.59" (in) in length only.  
1-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
JUIDB  
UID (Unit Identification) Switch  
LAN1/LAN2  
(IPMI) LAN  
SP1  
G-bit Ethernet Ports 1/2  
IPMI_Dedicated LAN  
Onboard Buzzer (Internal Speaker)  
(I-)SATA 0~5, SCU0~3  
Onboard Serial_Link Connections  
(I-)SATA 0~1 (X9DRD-LF)  
(SATA Connections 0~5, SCU Connections 0~3)  
(CPU1) Slot3, Slot4, Slot5,  
(CPU2) Slot7 (X9DRD-iF)  
PCI-Express 3.0 x8 Slots (See Note Below)  
(CPU2) Slot6 (X9DRD-iF)  
PCI-E x16 Slot (X9DRD-LF)  
(3-)SGPIO 1 (X9DRD-iF)  
PCI-Express 3.0 x16 Slot (See Note Below)  
PCI-Express 3.0 x16 Slot (from P1PE2) (See note on page 1-5)  
Serial_Link General Purpose I/O Headers for SCU Connec-  
tions  
(T-)SGPIO 1/2 (X9DRD-iF)  
(BP) USB 0/1, 2/3  
Serial ATA (SATA) General Purpose I/O Header  
Back Panel USB 0/1, 2/3  
(FP) USB 4/5, USB 8/9  
Front Panel Accessible USB Connections (4/5, 8/9)  
(FP USB4/5 only: X9DRD-LF)  
(FP) USB 6 (X9DRD-iF)  
VGA  
Type A USB Embedded Drive Connector  
Backpanel VGA Port  
LED Indicators  
LED  
Description  
State  
Status  
LED2  
LED3  
LEDM1  
Standby PWR LED  
Rear UID LED  
Green: On  
Blue: On  
Standby PWR On  
Unit Identified  
BMC Normal  
BMC Heartbeat LED  
Green: Blinking  
Warning: To avoid damaging your motherboard and components, please use a power  
supply that supports a 24-pin, two 4-pin and two 8-pin power connectors. Be sure to  
connect the 24-pin and the 8-pin power connectors to your power supply for adequate  
power delivery to your system. The 4-pin power connectors are optional; however,  
Supermicro recommends that these connectors also be plugged in for optimal power  
delivery.  
1-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1: Overview  
Motherboard Features  
Dual Intel® E5-2600(v2) Series Processors (Socket R  
LGA 2011); each processor supports four full-width Intel  
QuickPath Interconnect (QPI) links (with support of up  
to 25.6 GT/s per QPI link and with Data Transfer Rate  
of up to 8.0 GT/s per direction).  
CPU  
Note: For Intel E5-2600(v2) processor support,  
BIOS version 3.0 or above is required.  
Integrated memory controller supports up to 512 GB  
of Load Reduced (LRDIMM), 256 GB of Registered  
(RDIMM) or 64 GB of Unbuffered (UDIMM) ECC/Non-  
ECC DDR3 800/1066/1333/1600/1866 MHz 240-pin  
4-channel memory modules in eight DIMM slots.  
Memory  
Note 1: 1866 MHz memory speed is dependent  
on Intel E5-2600v2 CPUs.  
Note 2: For the latest memory updates, please  
refer to the Tested Memory List posted on our  
website (http://www.supermicro.com/products/  
motherboard).  
Virtualization: VT-x, VT-d, and VT-c  
Intel® C602 Chipset  
Chipset  
Expansion  
Slots  
Four (4) PCI Express 3.0 x8 slots (CPU1 Slot3/Slot4/  
Slot5 and CPU2 Slot 7)  
(X9DRD-iF)  
One (1) PCI Express 3.0 x16 slot (CPU2 Slot6)  
(X9DRD-iF)  
One (1) PCI Express 3.0 x16 slot (from P1PE2) (See  
note on page 1-5)  
(X9DRD-LF)  
Nutovon BMC Video Controller (Matrox G200eW)  
Graphics  
Network  
One Intel I350 Gigabit (10/100/1000 Mb/s) Ethernet Dual  
Port Controller for LAN 1/LAN 2 ports.  
Nuvoton WPCM450 Base-board Controller (BMC) sup-  
ports IPMI_LAN 2.0  
1-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Serial_Link Connections  
I/O De-  
vices  
SATA Ports  
Two (2) SATA 3.0 Ports (I-SATA0/1)  
Four (4) SATA 2.0 Ports (I-SATA2~5)  
(X9DRD-iF)  
(I-SATA 0/1 only: X9DRD-LF)  
Four SCU Connections (SCU0~3)  
(X9DRD-iF)  
RAID (Win-  
dows & Lat-  
est Linux)  
RAID 0, 1, 5, 10  
(RAID 5, 10: X9DRD-iF)  
Integrated IPMI 2.0  
IPMI 2.0 supported by the WPCM450R BMC  
Serial (COM) Port  
Two (2) Fast UART 16550 Connection: 9-pin RS-232  
port  
(COM1: X9DRD-LF)  
Super I/O  
Nuvoton 83527HG  
USB Devices  
Peripheral  
Devices  
Four (4) USB ports on the rear I/O panel (USB 0/1,  
USB 2/3)  
(Backpanel USB 0/1: X9DRD-LF)  
Four (4) USB connections for front access (USB 4/5,  
USB 8/9)  
(Front access USB 4/5: X9DRD-LF)  
One (1) Type A USB connection for front access (USB 6)  
(X9DRD-iF)  
16 MB SPI AMI BIOS® SM Flash BIOS  
BIOS  
APM 1.2, PCI 2.3, ACPI 1.0/2.0/3.0/4.0, USB Keyboard,  
Plug & Play (PnP) and SMBIOS 2.3  
ACPI/APM Power Management  
Main switch override mechanism  
Keyboard Wake-up from Soft-Off  
Power  
Config.  
1-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1: Overview  
Power-on mode for AC power recovery  
Intel® Intelligent Power Node Manager (NM) (Available  
when the NMView utility is installed in the system)  
Management Engine (ME)  
CPU Monitoring  
PC Health  
Monitoring  
Onboard voltage monitors for 1.8V, +3.3V, 3.3VSB, +5V,  
+5V SB, +12V, Chipset Voltage, and Battery Voltage.  
CPU 5-Phase switching voltage regulator  
CPU/System overheat LED and control  
CPU Thermal Trip support  
Thermal Monitor 2 (TM2) support  
Fan Control  
Fan status monitoring with firmware 4-pin (Pulse Width  
Modulation) fan speed control  
Low noise fan speed control  
PECI (Platform Environment Configuration Interface)  
System  
Manage-  
ment  
2.0 support  
UID (Unit Identification)/Remote UID  
System resource alert via SuperDoctor® III  
SuperDoctor® III, Watch Dog, NMI  
Chassis Intrusion Header and Detection  
13.00" (L) x 10.30" (W) (330.20 mm x 261.62 mm)  
Dimen-  
sions  
Note 1: For IPMI Configuration Instructions, please refer to the Embedded  
IPMI Configuration User's Guide available @ http://www.supermicro.com/  
support/manuals/.  
Note 2: Changing BMC log-in information is recommended during initial  
system power-on. The default username is ADMIN and password is  
ADMIN. For BMC best practices, please refer to: http://www.supermicro.  
com/products/nfo/files/IPMI/Best_Practices_BMC_Security.pdf  
1-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
X9DRD-iF Block Diagram  
DMI  
#1  
#1  
QPI  
QPI  
#1  
#1  
#1  
PE3  
(C,D)  
PE2 PE2 PE3 PE3  
PE1 PE2 PE2 PE3  
(A,B) (C,D)  
PE1  
G
(C,D)  
(A,B)(A,B)  
(A,B)  
(A,B)(C,D)  
(A,B)  
C
D
#1  
#1  
#1  
B
F
PROCESSOR 2 (right)  
PROCESSOR 1 (left)  
E
A
H
DMI  
PE1  
PE2  
PE3  
P0  
P1  
W25Q128  
SPI  
SCU  
DMI  
PEG0 [0..3]  
SSB  
AHCI  
PCH C602  
x4 (LANE1~4)  
PET [1~4]  
0,1  
2,3  
USB USB  
LPC  
PCI  
REAR REAR  
4,5  
6
8,9  
VGA  
BMC  
PHY1  
VGA CONN  
RTL8201F  
SIO  
W83527  
IPMI LAN  
System Block Diagram  
Note: This is a general block diagram and may not exactly represent the  
features on your motherboard. See the Motherboard Features pages for  
the actual specifications of each motherboard.  
1-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1: Overview  
X9DRD-LF Block Diagram  
PE1 PE2 PE2 PE3 PE3 DMI  
PE2 PE2 PE2 PE3 PE3  
A,B A,B C,D A,B C,D  
A,B A,B C,D A,B C,D  
QPI  
CPU0 LEFT  
E5-2600(v2)  
CPU1 RIGHT  
E5-2600(v2)  
H
#1  
D
#1  
#1  
#1  
B
F
#1  
#1  
#1  
#1  
P0  
P1  
G
C
A
E
P0  
DMI  
P1  
PE2  
PE3 PE2  
W25Q128  
SPI  
SATA GEN 3  
DMI  
PEG0 [0..3]  
PCH C602  
PCH C606  
RJ45  
RJ45  
x4 (Lane 1~4)  
i350  
USB  
0,1  
PET [1~4]  
GLAN  
USB  
LPC  
PET8  
x1  
REAR  
4,5  
HERMON  
VGA BMC  
TPM HDR  
SIO  
W03527  
PHY1  
VGA CONN  
RTL8201F  
IPMI LAN  
System Block Diagram  
Note: This is a general block diagram and may not exactly represent the  
features on your motherboard. See the Motherboard Features pages for  
the actual specifications of each motherboard.  
1-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
1-2 Processor and Chipset Overview  
Built upon the functionality and the capability of Intel E5-2600(v2) Series Proces-  
sors (Socket R LGA 2011) and the C602 chipset, the X9DRD-iF/LF motherboard  
provides the performance and feature sets required for dual processor-based  
HPC/Cluster/Database servers.  
With support of Intel QuickPath interconnect (QPI) Technology, the X9DRD-iF/LF  
offers point-to-point serial interconnect interface with a transfer speed of up to 8.0  
GT/s, providing superb system performance.  
The C602 chipset provides extensive IO support, including the following functions  
and capabilities:  
ACPI Power Management Logic Support, Rev. 4.0  
USB host interface with support of up to 9 connections  
Intel Rapid Storage Technology supported  
Intel Virtualization Technology for Directed I/O (Intel VT-d) supported  
Intel Trusted Execution Technology supported  
Serial Peripheral Interface (SPI) Supported  
Digital Media Interface (DMI) supported  
Advanced Host Controller Interface (AHCI) supported  
Note: For Intel E5-2600(v2) processor support, BIOS version 3.0 or above  
is required.  
1-12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1: Overview  
1-3 Special Features  
Recovery from AC Power Loss  
The Basic I/O System (BIOS) provides a setting that determines how the system will  
respond when AC power is lost and then restored to the system. You can choose for  
the system to remain powered off (in which case you must press the power switch  
to turn it back on), or for it to automatically return to the power-on state. See the  
Advanced BIOS Setup section for this setting. The default setting is Last State.  
1-4 PC Health Monitoring  
This section describes the features of PC health monitoring of the motherboard.  
This motherboard has an onboard System_Hardware_Monitor chip that supports  
PC health monitoring. An onboard voltage monitor will scan voltages and power  
usage continuously. Once a voltage becomes unstable, a warning is given, or an  
error message is sent to the screen. The user can adjust the voltage thresholds to  
define the sensitivity of the voltage monitor.  
Environmental Temperature Control  
A thermal control sensor monitors the CPU temperature in real time and will turn  
on the thermal control fan whenever the CPU temperature exceeds a user-defined  
threshold. The overheat circuitry runs independently from the CPU. Once it detects  
that the CPU temperature is too high, it will automatically turn on the thermal fan  
control to prevent the CPU from overheating. The onboard chassis thermal circuitry  
can monitor the overall system temperature and alert the user when the chassis  
temperature is too high.  
Note: To avoid possible system overheating, please be sure to provide  
adequate airflow to your system.  
System Resource Alert  
This feature is available when used with SuperDoctor® III in the Windows OS  
environment or used with SuperDoctor II in Linux. SuperDoctor is used to notify  
the user of certain system events. For example, you can configure SuperDoctor  
to provide you with warnings when the system temperature, CPU temperatures,  
voltages, and fan speeds go beyond a predefined range.  
1-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
1-5 ACPI Features  
ACPI stands for Advanced Configuration and Power Interface. The ACPI specifica-  
tion defines a flexible and abstract hardware interface that provides a standard  
way to integrate power management features throughout a PC system, including  
its hardware, operating system and application software. This enables the system  
to automatically turn on and off peripherals such as CD-ROMs, network cards, hard  
disk drives and printers.  
In addition to operating system-directed power management, ACPI also provides  
a generic system event mechanism for Plug and Play, and an operating system-  
independent interface for configuration control. ACPI leverages the Plug and Play  
BIOS data structures, while providing a processor architecture-independent imple-  
mentation that is compatible with Windows XP, Windows Vista and Windows 2008  
Operating Systems.  
Slow Blinking LED for Suspend-State Indicator  
When the CPU goes into a suspend state, the chassis power LED will start blinking  
to indicate that the CPU is in suspend mode. When the user presses any key, the  
CPU will "wake up," and the LED will automatically stop blinking and remain on.  
1-6 Power Supply  
As with all computer products, a stable power source is necessary for proper and  
reliable operation. It is even more important for processors that have high CPU  
clock rates.  
The X9DRD-iF/LF motherboard accommodates 24-pin ATX power supplies. Al-  
though most power supplies generally meet the specifications required by the  
CPU, some are inadequate. In addition, two 12V 8-pin power connections are also  
required to ensure adequate power supply to the system. Your power supply must  
also supply 1.5A for the Ethernet ports.  
Warning: To avoid damaging your motherboard and components, please use a power  
supply that supports a 24-pin, two 4-pin and two 8-pin power connectors. Be sure to  
connect the 24-pin and the 8-pin power connectors to your power supply for adequate  
power delivery to your system. The 4-pin power connectors are optional; however,  
Supermicro recommends that these connectors also be plugged in for optimal power  
delivery.  
It is strongly recommended that you use a high quality power supply that meets ATX  
power supply Specification 2.02 or above. It must also be SSI compliant. (For more  
information, please refer to the website at http://www.ssiforum.org/). Additionally, in  
areas where noisy power transmission is present, you may choose to install a line filter  
1-14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1: Overview  
to shield the computer from noise. It is recommended that you also install a power  
surge protector to help avoid problems caused by power surges.  
1-7 Super I/O  
The Super I/O supports two high-speed, 16550 compatible serial communication  
ports (UARTs). Each UART includes a 16-byte send/receive FIFO, a programmable  
baud rate generator, complete modem control capability, and a processor interrupt  
system. Both UARTs provide legacy speed with baud rate of up to 115.2 Kbps  
as well as an advanced speed with baud rates of 250 K, 500 K, or 1 Mb/s, which  
support higher speed modems.  
The Super I/O provides functions that comply with ACPI (Advanced Configuration  
and Power Interface), which includes support of legacy and ACPI power manage-  
ment through an SMI or SCI function pin. It also features auto power management  
to reduce power consumption.  
1-8 Advanced Power Management  
The following advanced power management features are supported by this moth-  
erboard:  
Intel® Intelligent Power Node Manager (NM) (Available  
when the NMView utility is installed in the system)  
The Intel® Intelligent Power Node Manager (IPNM) provides your system with  
real-time thermal control and power management for maximum energy efficiency.  
Although IPNM Specification Version 1.5/2.0 is supported by the BMC (Baseboard  
Management Controller), your system must also have IPNM-compatible Manage-  
ment Engine (ME) firmware installed to use this feature.  
Note: Support for IPNM Specification Version 1.5 or Vision 2.0 depends  
on the power supply used in the system.  
Management Engine (ME)  
The Management Engine, which is an ARC controller embedded in the PCH, pro-  
vides Server Platform Services (SPS) to your system. The services provided by  
SPS are different from those provided by the ME on client platforms.  
1-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
1-9 Overview of the Nuvoton WPCM450 Controller  
The Nuvoton WPCM450R Controller, a Baseboard Management Controller (BMC),  
supports 2D/VGA-compatible Graphic Cores with PCI interface, creating multi-media  
virtualization via Keyboard/Video/Mouse Redirection (KVMR). The WPCM450R  
Controller is ideal for remote system management.  
The WPCM450R Controller interfaces with the host system via PCI connections  
to communicate with the graphics cores. It supports USB 2.0 and 1.1 for remote  
keyboard/mouse/virtual media emulation. It also provides LPC interface support to  
control Super IO functions. The WPCM450R Controller is connected to the network  
via an external Ethernet PHY module or shared NCSI connections.  
The WPCM450R communicates with onboard components via six SMBus inter-  
faces, PECI (Platform Environment Control Interface) buses, and General Purpose  
I/O ports.  
Other Features Supported by the WPCM BMC Controller  
The WPCM450R supports the following features:  
IPMI 2.0  
Serial over LAN  
KVM over LAN  
LAN Alerting-SNMP Trap  
Event Log  
X-Bus parallel interface for I/O expansion  
Multiple ADC inputs, Analog and Digital Video outputs  
SPI Flash Host BIOS and firmware bootstrap program supported  
Reduced Media Independent Interface (RMII)  
OS (Operating System) Independency  
Provides remote Hardware Health Monitoring via IPMI. Key features  
Provides Network Management Security via remote access/console redirection.  
1-16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1: Overview  
Supports the following Management tools: IPMIView, CLI (Command Line  
Interface)  
RMCP+ protocol supported  
Note 1: For more information on IPMI configuration, please refer to the  
IPMI User's Guide posted on our website at http://www.supermicro.com/  
support/manuals/.  
Note 2: The term "IPMI controller" and the term "BMC controller" can be  
used interchangeably in this section.  
1-17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Notes  
1-18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
Chapter 2  
Installation  
2-1 Standardized Warning Statements  
The following statements are industry-standard warnings, provided to warn the user  
of situations which have the potential for bodily injury. Should you have questions or  
experience difficulty, contact Supermicro's Technical Support department for assis-  
tance. Only certified technicians should attempt to install or configure components.  
Read this section in its entirety before installing or configuring components in the  
Supermicro chassis.  
Battery Handling  
Warning!  
There is a danger of explosion if the battery is replaced incorrectly. Replace the  
battery only with the same or equivalent type recommended by the manufacturer.  
Dispose of used batteries according to the manufacturer's instructions  
電池のい  
電池交換がしくわれなかった場合裂の危険性がる電池はメー  
カーが推奨する型たは同  
等のものを使用下さい使用済電池は製造元の指示に従  
処分下さい。  
警告  
电池更换不当会有爆炸危险。请只使用同类电池或制造商推荐的功能相当的电池更  
换原有电池。请按制造商的说明处理废旧电池。  
警告  
電池更換不當會有爆炸危險。請使用製造商建議之相同或功能相當的電池更換原有  
電池。請按照製造商的說明指示處理廢棄舊電池。  
Warnung  
Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die  
Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp.  
Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers.  
2-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Attention  
Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer  
que par une pile de type semblable ou équivalent, recommandée par le fabricant.  
Jeter les piles usagées conformément aux instructions du fabricant.  
¡Advertencia!  
Existe peligro de explosión si la batería se reemplaza de manera incorrecta. Re-  
emplazar la batería exclusivamente con el mismo tipo o el equivalente recomen-  
dado por el fabricante. Desechar las baterías gastadas según las instrucciones  
del fabricante.  
!
אזהרה
 
ף
להחלי
 
יש
 .
תקינה
 
לא
 
בדרך
 
והוחלפה
 
במידה
 
הסוללה
 
של
 
פיצוץ
 
סכנת
 
קיימת
 
.
מומלצת
 
יצרן
 
מחברת
 
התואם
 
בסוג
 
הסוללה
 
את
 
.
היצרן
 
הוראות
 
לפי
 
לבצע
 
יש
 
המשומשות
 
הסוללות
 
סילוק
 
ل
ي
ل
فع
 
ة
حيح
ص
 
ر
ي
غ
 
قة
ي
طر
ب
 
ة
ري
بطا
ال
 
ل
ا
سحبذ
ا
 
ة
ل
ا
ح
 
في
 
ر
جا
ف
ن
ا
 
ن
م
 
خطر
 
هناك
 
ة
ري
بطا
ال
 
ل
ا
سحبذ
ا
 
ة
نع
المص
 
ة
م
شر
ال
 
ه
ب
 
أوصث
 
ا
م
م
 
ا
له
عاد
ي
 
ما
 
أو
 
ع
نى
ال
 
فس
ن
ب
 
ط
فق
 
ة
ع
ن
ا
الص
 
ة
م
شر
ال
 
ات
م
ي
ل
حع
ل
 
وفقا
 
ة
ل
م
حع
س
الم
 
ات
ري
بطا
ال
 
ن
م
 
ص
ل
جخ
 
경고!  
배터리가 올바르게 교체되지 않으면 폭발의 위험이 있습니다. 기존 배터리와 동일  
하거나 제조사에서 권장하는 동등한 종류의 배터리로만 교체해야 합니다. 제조사  
의 안내에 따라 사용된 배터리를 처리하여 주십시오.  
Waarschuwing  
Er is ontploffingsgevaar indien de batterij verkeerd vervangen wordt. Vervang de  
batterij slechts met hetzelfde of een equivalent type die door de fabrikant aan-  
bevolen wordt. Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften  
afgevoerd te worden.  
2-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
Product Disposal  
Warning!  
Ultimate disposal of this product should be handled according to all national laws  
and regulations.  
製品の廃棄  
製品を廃棄処分る場合関係る全ての法例に従い処理る必要  
ありす。  
警告  
本产品的废弃处理应根据所有国家的法律和规章进行。  
警告  
本產品的廢棄處理應根據所有國家的法律和規章進行。  
Warnung  
Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen  
des Landes erfolgen.  
¡Advertencia!  
Al deshacerse por completo de este producto debe seguir todas las leyes y regla-  
mentos nacionales.  
Attention  
La mise au rebut ou le recyclage de ce produit sont généralement soumis à des  
lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de  
l'organisme compétent.  
ר
המוצ
 
סילוק
 
!
אזהרה
 
.
המדינה
 
וחוקי
 
להנחיות
 
בהתאם
 
להיות
 
חייב
 
זה
 
מוצר
 
של
 
סופי
 
סילוק
 
2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
ة
ي
لىطن
ا
 
ئح
ا
ى
ل
ل
ا
و
 
ن
ني
ا
لقى
ا
 
ع
ي
جم
ل
 
وفقا
 
ه
مع
 
ل
لتعام
ا
 
نبغي
ي
 
نتج
م
ل
ا
 
ا
ذ
ه
 
ن
م
 
لنهائي
ا
 
ص
ل
لتخ
ا
 
ند
ع
 
경고!  
이 제품은 해당 국가의 관련 법규 및 규정에 따라 폐기되어야 합니다.  
Waarschuwing  
De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming  
met alle nationale wetten en reglementen.  
2-2 Static-Sensitive Devices  
Electrostatic Discharge (ESD) can damage electronic components. To avoid dam-  
aging your system board, it is important to handle it very carefully. The following  
measures are generally sufficient to protect your equipment from ESD.  
Precautions  
Use a grounded wrist strap designed to prevent static discharge.  
Touch a grounded metal object before removing the board from the antistatic  
bag.  
Handle the board by its edges only; do not touch its components, peripheral  
chips, memory modules or gold contacts.  
When handling chips or modules, avoid touching their pins.  
Put the motherboard and peripherals back into their antistatic bags when not  
in use.  
For grounding purposes, make sure that your system chassis provides excellent  
conductivity between the power supply, the case, the mounting fasteners and  
the motherboard.  
Unpacking  
The motherboard is shipped in antistatic packaging to avoid static damage. When  
unpacking the board, make sure that the person handling it is static protected.  
2-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
2-3 Processor and Heatsink Installation  
Warning: When handling the processor package, avoid placing direct pressure on  
the label area.  
Notes:  
Always connect the power cord last, and always remove it before adding, re-  
moving or changing any hardware components. Make sure that you install the  
processor into the CPU socket before you install the CPU heatsink.  
If you buy a CPU separately, make sure that you use an Intel-certified multi-  
directional heatsink only.  
Make sure to install the motherboard into the chassis before you install the  
CPU heatsink.  
When receiving a motherboard without a processor pre-installed, make sure that  
the plastic CPU socket cap is in place and none of the socket pins are bent;  
otherwise, contact your retailer immediately.  
Refer to the Supermicro website for updates on CPU support.  
Installing the LGA2011 Processor  
1. There are two load levers on the LGA2011 socket. To open the socket cover,  
first press and release the load lever labeled 'Open 1st'.  
2
1
W
W
ARNING  
ARNING  
!
!
OPEN 1st  
OPEN 1st  
Press down  
on Load Lever  
labeled 'Open 1st'.  
2-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
2. Press the second load lever labeled 'Close 1st' to release the load plate that  
covers the CPU socket from its locking position.  
Press down on Load  
Lever 'Close 1st'  
Pull lever away from  
the socket  
2
1
W
ARNING  
W
ARNING  
!
!
OPEN 1st  
OPEN 1st  
3. With the lever labeled 'Close 1st' fully retracted, gently push down on the  
lever labelled 'Open 1st' to open the load plate. Lift the load plate to open it  
completely.  
Gently push  
down to pop the  
load plate open.  
1
2
W
ARNING  
!
OPEN 1st  
W
ARNING  
!
2-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
1. Using your thumb and the index finger, remove the 'WARNING' plastic cap  
from the socket.  
W
ARNING  
!
2. Using your thumb and index finger, hold the CPU on its edges. Align the CPU  
keys, which are semi-circle cutouts, against the socket keys.  
Socket Keys  
CPU Keys  
3. Once they are aligned, carefully lower the CPU straight down into the socket.  
(Do not drop the CPU on the socket. Do not move the CPU horizontally or  
vertically. Do not rub the CPU against the surface or against any pins of the  
socket to avoid damaging the CPU or the socket.)  
Warning: You can only install the CPU  
inside the socket in one direction. Make  
sure that it is properly inserted into the  
CPU socket before closing the load  
plate. If it doesn't close properly, do not  
force it as it may damage your CPU.  
Instead, open the load plate again to  
make sure that the CPU is aligned  
properly.  
2-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
4. With the CPU inside the socket, inspect the four corners of the CPU to make  
sure that the CPU is properly installed.  
5. Close the load plate with the CPU inside the socket. Lock the lever labelled  
'Close 1st' first, then lock the lever labelled 'Open 1st' second. Using your  
thumb gently push the load levers down to the lever locks.  
Gently close  
the load plate.  
Push down and lock the  
lever labelled 'Close 1st'.  
1
2
OPEN 1st  
4
3
Push down and  
lock the lever  
labelled 'Open  
1st'.  
Lever Lock  
OPEN 1st  
OPEN 1st  
Lever Lock  
2-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
Installing a Passive CPU Heatsink  
1. Do not apply any thermal grease to the heatsink or the CPU die -- the re-  
quired amount has already been applied.  
2. Place the heatsink on top of the CPU so that the four mounting holes are  
aligned with those on the Motherboard's and the Heatsink Bracket under-  
neath.  
3. Screw in two diagonal screws (i.e., the #1 and the #2 screws) until just snug  
(-do not over-tighten the screws to avoid possible damage to the CPU.)  
4. Finish the installation by fully tightening all four screws.  
Screw#1  
Screw#2  
Motherboard  
OPEN 1s  
t
Mounting Holes  
Note: For optimized airflow, please follow your chassis airflow direction  
to install the correct CPU heatsink direction. Graphic drawings included  
in this manual are for reference only. They might look different from the  
components installed in your system  
2-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Removing the Heatsink  
Warning: We do not recommend that the CPU or the heatsink be removed. However,  
if you do need to uninstall the heatsink, please follow the instructions below to uninstall  
the heatsink to prevent damage done to the CPU or the CPU socket.  
1. Unscrew the heatsink screws from the motherboard in the sequence as  
shown in the illustration below.  
2. Gently wriggle the heatsink to loosen it from the CPU. (Do not use excessive  
force when wriggling the heatsink!)  
3. Once the CPU is loosened, remove the CPU from the CPU socket.  
4. Remove the used thermal grease and clean the surface of the CPU and the  
heatsink, Reapply the proper amount of thermal grease on the surface before  
reinstalling the CPU and the heatsink. (Do not reuse old thermal grease.)  
Loosen screws  
in sequence as  
shown.  
Screw#4  
Screw#1  
Screw#2  
Motherboard  
Screw#3  
2-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
2-4 Installing and Removing the Memory Modules  
Note: Check Supermicro's website for recommended memory modules.  
CAUTION  
Exercise extreme care when installing or removing DIMM  
modules to prevent any possible damage.  
Installing & Removing DIMMs  
1. Insert the desired number of DIMMs into the memory slots, starting with P1-  
DIMMA1.  
2. Push the release tabs outwards on both ends of the DIMM slot to unlock it.  
USB2/3  
USB0/1  
COM2  
JUIDB  
COM1  
VGA  
USB6  
BMC  
Notches  
FAN8  
JPG1  
JPB1  
FAN7  
LAN2  
LAN1  
LAN CTRL  
IPMI_LAN  
LAN  
CTRL  
SP1  
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
JBT1  
CPU2  
BIOS  
B1  
A1  
C1  
D1  
CPU1  
Release Tabs  
JBAT1  
JOH1  
:
O
H
L
E
D
LED2  
JPW5  
FAN4  
JVR1  
3. Align the key of the DIMM module with the receptive point on the memory  
slot.  
4. Align the notches on both ends of the module against the receptive points on  
the ends of the slot.  
5. Use two thumbs together to press the notches on both ends of the module  
straight down into the slot until the module snaps into place.  
6. Press the release tabs to the locking positions to secure the DIMM module  
into the slot.  
Press both notches straight  
down into the memory slot at  
the same time.  
Removing Memory Modules  
Press both notches on the ends of the DIMM module to unlock it. Once it is loos-  
ened, once it is loosened, remove it from the memory slot.  
2-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Memory Support for the X9DRD-iF/LF Motherboard  
The X9DRD-iF/LF motherboard supports up to 512 GB of Load Reduced (LRDIMM),  
256 GB of Registered (RDIMM) or 64 GB of Unbuffered (UDIMM) ECC/Non-ECC  
DDR3 800/1066/1333/1600/1866 MHz 240-pin 4-channel memory modules in eight  
DIMM slots.  
Note: For the latest memory updates, please refer to the Tested Memory  
List posted on our website (http://www.supermicro.com/products/mother-  
board).  
Processor & Memory Module Population Configuration  
For memory to work properly, follow the tables below for memory installation.  
Processors and their Corresponding Memory Modules  
CPU#  
CPU1  
CPU2  
Corresponding DIMM Modules  
P1-DIMMA1 P1-DIMMB1  
P2-DIMME1 P2-DIMMF1  
P1-DIMMC1  
P2-DIMMG1  
P1-DIMMD1  
P2-DIMMH1  
Processor and Memory Module Population  
Number of  
CPU and Memory Population Configuration Table  
CPUs+DIMMs  
(*For memory to work proper, please install DIMMs in pairs)  
1 CPU &  
2 DIMMs  
CPU1  
P1-DIMMA1/P1-DIMMB1  
1 CPU &  
4 DIMMs  
CPU1  
P1-DIMMA1/P1-DIMMB1, P1-DIMMC1/P1-DIMMD1  
2 CPUs &  
2 DIMMs  
CPU1 + CPU2  
P1-DIMMA1, P2-DIMME1  
2 CPUs &  
4 DIMMs  
CPU1 + CPU2  
P1-DIMMA1/P1-DIMMB1, P2-DIMME1/P2-DIMMF1  
2 CPUs &  
6 DIMMs  
CPU1 + CPU2  
P1-DIMMA1/P1-DIMMB1/P1-DIMMC1, P2-DIMME1/P2-DIMMF1/P2-DIMMG1  
2 CPUs &  
8 DIMMs  
CPU1 + CPU2  
P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1/P2-  
DIMMG1/P2-DIMMH1  
Notes: 1866 MHz memory speed is dependent on Intel E5-2600v2 CPUs.  
For Intel E5-2600(v2) processor support, BIOS version 3.0 or above is  
required.  
2-12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
Populating UDIMM (ECC/Non-ECC) Memory Modules  
Intel E5-2600(v2) Series Processor UDIMM Memory Support  
Ranks  
Per  
Memory Capacity  
Per DIMM  
Speed (MT/s) and Voltage Validated by Slot per Channel (SPC) and  
DIMM Per Channel (DPC)  
DIMM  
& Data  
Width  
2 Slots Per Channel  
1DPC 2DPC  
3 Slots Per Channel  
(See the Note below)  
1DPC  
2DPC  
1.35V 1.5v  
1.35V  
1.5V  
1.35V  
1.5V  
1.35V 1.5V  
SRx8  
Non-  
ECC  
1GB  
2GB  
2GB  
4GB  
1GB  
2GB  
4GB  
8GB  
2GB  
4GB  
NA  
NA  
NA  
1066,  
1333,  
1600,  
1866  
NA  
1066, N/A  
1333,  
1600  
1066,  
1333,  
1600,  
1866  
N/A  
N/A  
N/A  
1066,  
1333,  
1600  
DRx8  
Non-  
ECC  
1066,  
1333,  
1600,  
1866  
NA  
NA  
1066, N/A  
1333,  
1600  
1066,  
1333,  
1600,  
1866  
1066,  
1333,  
1600  
SRx16  
Non-  
ECC  
512MB  
1GB  
1066,  
1333,  
1600,  
1866  
1066, N/A  
1333,  
1600  
1066,  
1333,  
1600,  
1866  
1066,  
1333,  
1600  
SRx8  
ECC  
1066,  
1333  
1066, 1066,  
1066, 1066,  
1333, 1333  
1600  
1066,  
1333,  
1600,  
1866  
1066,  
1333  
1066,  
1333,  
1600  
1333,  
1600,  
1866  
1333  
DRx8  
ECC  
2GB  
4GB  
8GB  
1066,  
1333  
1066, 1066,  
1066, 1066,  
1333, 1333  
1600  
1066,  
1333,  
1600,  
1866  
1066,  
1333  
1066,  
1333,  
1600  
1333,  
1600,  
1866  
1333  
Note: For detailed information on memory support and updates, please refer to the SMC Recommended  
Memory List posted on our website at http://www.supermicro.com/support/resources/mem.cfm.  
Populating RDIMM (ECC) Memory Modules  
Intel E5-2600(v2) Series Processor RDIMM Memory Support  
Ranks  
Per  
Memory Capacity  
Per DIMM  
Speed (MT/s) and Voltage Validated by Slot per Channel (SPC) and DIMM Per Channel  
(DPC)  
DIMM  
&
Data  
Width  
2 Slots Per Channel  
1DPC 2DPC  
3 Slots Per Channel  
2DPC  
(See the Note Below)  
1 DPC  
3DPC  
1.35V 1.5v  
1.35V  
1.5V  
1.35V  
1.5V  
1.35V 1.5V  
1.35V  
1.5V  
SRx8  
DRx8  
SRx4  
DRx4  
1GB  
2GB  
2GB  
4GB  
2GB  
4GB  
4GB  
8GB  
4GB  
8GB  
1066,  
1333  
1066,  
1333,  
1600,  
1866  
1066,  
1333  
1066,  
1333,  
1600  
1066,  
1333  
1066,  
1066,  
1333  
1066, 800  
1333,  
1600  
800,  
1066  
1333,  
1600,  
1866  
1066,  
1333  
1066,  
1333,  
1600,  
1866  
1066,  
1333  
1066,  
1333,  
1600  
1066,  
1333  
1066,  
1333,  
1600,  
1866  
1066,  
1333  
1066, 800  
1333,  
1600  
800,  
1066  
8GB  
1066,  
1333  
1066,  
1333,  
1600,  
1866  
1066,  
1333  
1066,  
1333,  
1600  
1066,  
1333  
1066,  
1333,  
1600,  
1866  
1066,  
1333  
1066, 800  
1333,  
1600  
800,  
1066  
16GB  
1066,  
1333  
1066,  
1333,  
1600,  
1866  
1066,  
1333  
1066,  
1333,  
1600  
1066,  
1333  
1066,  
1333,  
1600,  
1866  
1066,  
1333  
1066, 800  
1333,  
1600  
800,  
1066  
QRx4  
QRx8  
8GB  
4GB  
16GB  
8GB  
32GB  
16GB  
800  
800  
800  
1066  
800  
800  
800  
800  
800  
800  
800,  
1066  
800  
800  
800  
800  
N/A  
N/A  
N/A  
N/A  
800  
800,  
1066  
1066  
Note: For detailed information on memory support and updates, please refer to the SMC Recommended Memory List posted on  
our website at http://www.supermicro.com/support/resources/mem.cfm.  
2-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Populating UDIMM (ECC/Non-ECC) Memory Modules  
Intel E5-2600 Series Processor UDIMM Memory Support  
Ranks  
Per  
Memory Capacity  
Per DIMM  
Speed (MT/s) and Voltage Validated by Slot per Channel (SPC) and  
DIMM Per Channel (DPC)  
DIMM  
& Data  
Width  
2 Slots Per Channel  
1DPC 2DPC  
3 Slots Per Channel  
(See the Note below)  
1DPC  
2DPC  
1.35V 1.5v  
1.35V  
1.5V  
1.35V  
1.5V  
1.35V 1.5V  
SRx8  
Non-  
ECC  
1GB  
2GB  
2GB  
4GB  
1GB  
2GB  
4GB  
4GB  
8GB  
2GB  
4GB  
8GB  
NA  
NA  
NA  
1066,  
1333  
NA  
1066, N/A  
1333  
1066,  
1333,  
N/A  
N/A  
N/A  
1066,  
1333  
DRx8  
Non-  
ECC  
1066,  
1333  
NA  
NA  
1066, N/A  
1333  
1066,  
1333,  
1066,  
1333  
SRx16  
Non-  
ECC  
512MB  
1GB  
1066,  
1333  
1066, N/A  
1333  
1066,  
1333  
1066,  
1333  
SRx8  
ECC  
1066,  
1333  
1066,  
1333  
1066  
1066  
1066, 1066  
1333  
1066,  
1333,  
1066,  
1333  
1066,  
1333  
DRx8  
ECC  
2GB  
1066,  
1333  
1066,  
1333  
1066, 1066  
1333  
1066,  
1333,  
1066,  
1333  
1066,  
1333  
Note: For detailed information on memory support and updates, please refer to the SMC Recommended  
Memory List posted on our website at http://www.supermicro.com/support/resources/mem.cfm.  
Populating RDIMM (ECC) Memory Modules  
Intel E5-2600 Series Processor RDIMM Memory Support  
Ranks  
Per  
Memory Capacity  
Per DIMM  
Speed (MT/s) and Voltage Validated by Slot per Channel (SPC) and DIMM Per Channel  
(DPC)  
DIMM  
&
Data  
Width  
2 Slots Per Channel  
1DPC 2DPC  
3 Slots Per Channel  
2DPC  
(See the Note Below)  
1 DPC  
3DPC  
1.35V 1.5v  
1.35V  
1.5V  
1.35V  
1.5V  
1.35V 1.5V  
1.35V  
1.5V  
SRx8  
1GB  
2GB  
4GB  
1066,  
1333  
1066,  
1333,  
1600  
1066,  
1333  
1066,  
1333,  
1600  
1066,  
1333  
1066,  
1333,  
1600  
1066,  
1333  
1066, N/A  
1333,  
1600  
800,  
1066  
DRx8  
SRx4  
2GB  
2GB  
4GB  
4GB  
8GB  
8GB  
1066,  
1333  
1066,  
1333,  
1600  
1066,  
1333  
1066,  
1333,  
1600  
1066,  
1333  
1066,  
1333,  
1600  
1066,  
1333  
1066, N/A  
1333,  
1600  
800,  
1066  
1066,  
1333  
1066,  
1333,  
1600  
1066,  
1333  
1066,  
1333,  
1600  
1066,  
1333  
1066,  
1333,  
1600  
1066,  
1333  
1066, N/A  
1333,  
1600  
800,  
1066  
DRx4  
4GB  
8GB  
16GB  
1066,  
1333  
1066,  
1333,  
1600  
1066,  
1333  
1066,  
1333,  
1600  
1066,  
1333  
1066,  
1333,  
1600  
1066,  
1333  
1066, N/A  
1333,  
1600  
800,  
1066  
QRx4  
QRx8  
8GB  
4GB  
16GB  
8GB  
32GB  
16GB  
800  
800  
1066  
800  
800  
800  
800  
800  
1066  
800  
800  
800  
N/A  
N/A  
N/A  
N/A  
1066  
800  
1066  
800  
Note: For detailed information on memory support and updates, please refer to the SMC Recommended Memory List posted on  
our website at http://www.supermicro.com/support/resources/mem.cfm.  
2-14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
Populating LRDIMM (ECC) Memory Modules  
Intel E5-2600(v2) Series Processor LRDIMM Memory Support  
Ranks  
Per  
DIMM  
&
Data  
Width  
Memory  
Capacity  
Per DIMM  
Speed (MT/s) and Voltage Validated by Slot per Channel (SPC) and DIMM Per  
Channel (DPC)  
2 Slots Per Channel  
1DPC 2DPC  
3 Slots Per Channel  
2DPC  
(See the Note  
Below)  
1DPC  
3DPC  
1.35V  
1.5V  
1.35V  
1.5V  
1.35V  
1.5V  
1.35V  
1.5V  
1.35V 1.5V  
QRx4  
(DDP)  
16GB 32GB  
32GB 64GB  
1066,  
1333,  
1600  
1066,  
1333,  
1600,  
1866  
1066,  
1333,  
1600  
1066,  
1333,  
1600  
1066,  
1333,  
1600  
1066,  
1333,  
1600,  
1866  
1066,  
1333,  
1600  
1066, 1066  
1333,  
1600  
1066  
8Rx4  
1066  
1066 1066  
1066  
1066  
1066  
1066  
1066  
1066  
1066  
(QDP)  
Note: For detailed information on memory support and updates, please refer to the SMC Recommended Memory  
List posted on our website at http://www.supermicro.com/support/resources/mem.cfm.  
Intel E5-2600 Series Processor LRDIMM Memory Support  
Ranks  
Per  
DIMM  
&
Data  
Width  
Memory  
Capacity  
Per DIMM  
Speed (MT/s) and Voltage Validated by Slot per Channel (SPC) and DIMM Per  
Channel (DPC)  
2 Slots Per Channel  
1DPC 2DPC  
3 Slots Per Channel  
2DPC  
(See the Note  
Below)  
1DPC  
3DPC  
1.35V  
1.5V  
1.35V  
1.5V  
1.35V  
1.5V  
1.35V  
1.5V  
1.35V 1.5V  
QRx4  
(DDP)  
16GB 32GB  
1066  
1066  
1066,  
1333  
1066  
1066,  
1333  
1066  
1066  
1066,  
1333  
1066  
1066, 1066  
1333  
1066  
1066  
QRx8  
(QDP)  
8GB  
16GB  
1066, 1066  
1333  
1066,  
1333  
1066  
1066  
1066  
1066  
Note: For detailed information on memory support and updates, please refer to the SMC Recommended Memory  
List posted on our website at http://www.supermicro.com/support/resources/mem.cfm.  
Other Important Notes and Restrictions  
For the memory modules to work properly, please install DIMM modules of the same  
type, same speed and same operating frequency on the motherboard. Mixing of  
RDIMMs, UDIMMs or LRDIMMs is not allowed. Do not install both ECC and Non-ECC  
memory modules on the same motherboard.  
Using DDR3 DIMMs with different operating frequencies is not allowed. All channels  
in a system will run at the lowest common frequency.  
2-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
2-5 Motherboard Installation  
All motherboards have standard mounting holes to fit different types of chassis.  
Make sure that the locations of all the mounting holes for both motherboard and  
chassis match. Although a chassis may have both plastic and metal mounting fas-  
teners, metal ones are highly recommended because they ground the motherboard  
to the chassis. Make sure that the metal standoffs click in or are screwed in tightly.  
Then use a screwdriver to secure the motherboard onto the motherboard tray.  
Tools Needed  
Phillips Screwdriver  
Pan head screws (9 pieces)  
Standoffs (9 pieces, if needed)  
USB2/3  
USB0/1  
COM2  
Location of  
Mounting Holes  
JUIDB  
COM1  
VGA  
USB6  
BMC  
LAN CTRL  
FAN7  
LAN2  
LAN1  
FAN8  
JPG1  
JPB1  
IPMI_LAN  
LAN  
CTRL  
SP1  
There are nine (9) mounting  
holes on this motherboard. See  
the layout on the right.  
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
JBT1  
CPU2  
BIOS  
B1  
A1  
C1  
D1  
CPU1  
JBAT1  
JOH1  
:
O
H
L
E
D
LED2  
JPW5  
FAN4  
JVR1  
Warning: 1) To avoid damaging the motherboard and its components, please do  
not use a force greater than 8 lb/inch on each mounting screw during motherboard  
installation. 2) Some components are very close to the mounting holes. Please take  
precautionary measures to prevent damage to these components when installing the  
motherboard to the chassis.  
An Important Note on PCI-E Slot Population  
Note: PCI-E slots support Low-Profile MD2 form factor, please install PCI-E  
devices or add-on cards that are shorter than 167.64mm or 6.59"(in.) in  
the PCI-E slots only.  
2-16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
Installing the Motherboard  
1. Install the I/O shield into the chassis.  
2. Locate the mounting holes on the motherboard.  
3. Locate the matching mounting holes on the chassis. Align the mounting holes  
on the motherboard against the mounting holes on the chassis.  
4. Install standoffs in the chassis as needed.  
5. Install the motherboard into the chassis carefully to avoid damaging mother-  
board components.  
6. Using the Phillips screwdriver, insert a Pan head #6 screw into a mounting  
hole on the motherboard and its matching mounting hole on the chassis.  
7. Repeat Step 5 to insert #6 screws into all mounting holes.  
8. Make sure that the motherboard is securely placed in the chassis.  
Note: Images displayed are for illustration only. Your chassis or compo-  
nents might look different from those shown in this manual.  
2-17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
2-6 Control Panel Connectors and I/O Ports  
The I/O ports are color coded in conformance with the PC 99 specification. See  
the picture below for the colors and locations of the various I/O ports.  
Back Panel Connectors and I/O Ports  
USB2/3  
USB0/1  
COM2  
JUIDB  
COM1  
VGA  
USB6  
BMC  
LAN CTRL  
FAN7  
LAN2  
LAN1  
FAN8  
JPG1  
JPB1  
IPMI_LAN  
LAN  
CTRL  
4
SP1  
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
1
6
5
7
8
9
10  
3
JBT1  
CPU2  
2
BIOS  
B1  
A1  
C1  
D1  
CPU1  
JBAT1  
JOH1  
:
O
H
L
E
D
LED2  
JPW5  
FAN4  
JVR1  
Back Panel I/O Port Locations and Definitions  
1. COM Port 1 (Turquoise)  
2. Back Panel USB Port 0  
3. Back Panel USB Port 1  
4. IPMI_Dedicated LAN  
5. Back Panel USB Port 2  
6. Back Panel USB Port 3  
7. Gigabit LAN 1  
8. Gigabit LAN 2  
9. Back Panel VGA (Blue)  
10. UID Switch  
2-18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
Serial Ports  
Serial COM) Ports  
Pin Definitions  
Two COM connections (COM1 &  
COM2) are located on the mother-  
board. COM1 is located on the Back-  
plane I/O panel. COM2, located close  
to CPU Slot3, provides front access  
support. See the table on the right for  
pin definitions.  
Pin #  
Definition Pin #  
Definition  
DSR  
1
2
3
4
5
DCD  
RXD  
6
7
8
9
RTS  
CTS  
RI  
TXD  
DTR  
Ground  
10  
N/A  
Note: X9DRD-iF has  
COM1 and COM2. X9DRD-  
LF only has COM1.  
1
2
Video Connection  
A Video (VGA) port is located next  
to LAN2 on the I/O backplane. Refer  
to the board layout below for the  
location.  
3
2
1. COM1  
USB2/3  
USB0/1  
COM2  
JUIDB  
COM1  
VGA  
USB6  
2. COM2  
3. VGA  
BMC  
LAN CTRL  
FAN7  
LAN2  
LAN1  
FAN8  
JPG1  
JPB1  
IPMI_LAN  
LAN  
CTRL  
SP1  
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
JBT1  
CPU2  
BIOS  
B1  
A1  
C1  
D1  
CPU1  
JBAT1  
JOH1  
:
O
H
L
E
D
LED2  
JPW5  
3
1
FAN4  
JVR1  
2-19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Universal Serial Bus (USB)  
FP USB (4/5, 8/9, USB 6)  
Backplane  
USB (0/1, 2/3)  
Pin Definitions  
Four Universal Serial Bus ports (USB Pin Definitions  
USB 4, 8, 6,  
Pin # Definition  
USB 5, 9  
Pin # Definition  
0/1, USB 2/3) are located on the I/O  
Pin# Definition  
1
2
3
4
5
+5V  
1
2
3
4
5
+5V  
back panel. In addition, three USB  
1
2
3
4
5
+5V  
PO-  
PO-  
headers, located close to the IO Hub,  
provides four front-accessible USB  
connections (USB 4/5, USB 8/9).  
One Type A connector (USB6) also  
supports front panel USB connection.  
(Cables are not included). See the  
tables on the right for pin definitions.  
PO-  
PO+  
Ground  
NC  
PO+  
Ground  
Key  
PO+  
Ground  
NA  
(NC= No connection)  
Note 1: X9DRD-iF has the  
front-accessible USB 4/5  
and USB 8/9. X9DRD-LF  
only has USB 4/5.  
Note 2: X9DRD-iF has the  
backpanel USB 0/1 and USB  
2/3. X9DRD-LF only has the  
backpanel USB 0/1.  
1. Backpanel USB 0  
2. BP USB 1  
USB2/3  
USB0/1  
COM2  
JUIDB  
COM1  
VGA  
USB6  
BMC  
LAN CTRL  
7
FAN7  
LAN2  
LAN1  
FAN8  
JPG1  
JPB1  
IPMI_LAN  
LAN  
CTRL  
3. BP USB 2  
SP1  
4. BP USB 3  
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
5. FP USB 4/5  
6. FP USB 8/9  
7. FP USB 6  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
JBT1  
CPU2  
BIOS  
B1  
A1  
C1  
D1  
CPU1  
JBAT1  
JOH1  
:
O
H
L
E
D
5
LED2  
JPW5  
6
FAN4  
2
1
4
3
JVR1  
2-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
Ethernet Ports  
LAN Ports  
Pin Definition  
Two Gigabit Ethernet ports (LAN1,  
LAN2) are located on the I/O back-  
plane on the motherboard. In addition,  
an IPMI_Dedicated LAN is located  
above USB 0/1 ports on the backplane  
to provide KVM support for IPMI 2.0.  
All these ports accept RJ45 type ca-  
bles. Please refer to the LED Indicator  
Section for LAN LED information.  
Pin# Definition  
1
2
3
4
P2V5SB  
TD0+  
10  
11  
12  
13  
SGND  
Act LED  
P3V3SB  
TD0-  
TD1+  
Link 100 LED (Yel-  
low, +3V3SB)  
5
TD1-  
14  
Link 1000 LED  
(Yellow, +3V3SB)  
6
7
8
9
TD2+  
TD2-  
TD3+  
TD3-  
15  
16  
17  
18  
Ground  
Ground  
Ground  
Ground  
(NC: No Connection)  
1. GLAN1  
2. GLAN2  
3. IPMI_LAN  
USB2/3  
USB0/1  
COM2  
JUIDB  
COM1  
VGA  
USB6  
BMC  
FAN7  
LAN2  
LAN1  
FAN8  
JPG1  
JPB1  
LAN CTRL  
IPMI_LAN  
LAN  
CTRL  
SP1  
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
JBT1  
CPU2  
BIOS  
B1  
A1  
C1  
D1  
CPU1  
3
JBAT1  
JOH1  
:
O
H
L
E
D
LED2  
JPW5  
FAN4  
JVR1  
1
2
2-21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Unit Identifier Switch/UID LED Indicators  
UID Switch  
Pin# Definition  
A Unit Identifier (UID) Switch and two LED Indi-  
cators are located on the motherboard. The UID  
Switch is located next to the VGA port on the  
backplane. The Rear UID LED (LED3) is located  
next to the UID Switch. The Front Panel UID  
LED is located at pins 7/8 of the Front Control  
Panel at JF1. Connect a cable to pin 8 on JF1  
for Front Panel UID LED indication. When you  
press the UID switch, both Rear UID LED and  
Front Panel UID LED Indicators will be turned  
on. Press the UID switch again to turn off both  
LED Indicators. These UID Indicators provide  
easy identification of a system unit that may be  
in need of service.  
1
2
3
4
Ground  
Ground  
Button In  
Ground  
UID LED (LED3)  
Status  
Color/State Status  
Blue: On Unit Identified  
Note: UID can also be triggered via  
IPMI on the motherboard. For more  
information on IPMI, please refer to the  
IPMI User's Guide posted on our web-  
site @ http://www.supermicro.com.  
1. UID Switch  
2. Rear UID LED (LED3)  
3. Front UID LED  
2 1  
USB2/3  
USB0/1  
COM2  
JUIDB  
COM1  
VGA  
USB6  
BMC  
LAN CTRL  
FAN7  
LAN2  
LAN1  
FAN8  
JPG1  
JPB1  
IPMI_LAN  
LAN  
CTRL  
SP1  
20 19  
JI2C1  
JI2C2  
CLK CTRL  
Ground  
NMI  
JPW4  
X
X9DRD-iF  
X
Rev. 1.10  
3.3 V  
FP PWRLED  
HDD LED  
PCH  
F1  
E1  
G1  
H1  
JBT1  
CPU2  
ID_UID_SW/3/3V Stby  
NIC1 Activity LED  
NIC2 Activity LED  
Red+ (Blue LED Cathode)  
3.3V  
NIC1 Link LED  
BIOS  
NIC2 Link LED  
3
B1  
A1  
C1  
D1  
Blue+ (OH/Fan Fail/  
PWR FaiL/UID LED)  
CPU1  
Power Fail LED  
Reset  
PWR  
Reset Button  
Power Button  
Ground  
Ground  
JBAT1  
JOH1  
2
1
:
O
H
L
E
D
LED2  
JPW5  
FAN4  
JVR1  
1
2-22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
Front Control Panel  
JF1 contains header pins for various buttons and indicators that are normally lo-  
cated on a control panel at the front of the chassis. These connectors are designed  
specifically for use with Supermicro's server chassis. See the figure below for the  
descriptions of the various control panel buttons and LED indicators. Refer to the  
following section for descriptions and pin definitions.  
USB2/3  
USB0/1  
COM2  
JUIDB  
COM1  
VGA  
USB6  
BMC  
FAN7  
LAN2  
LAN1  
FAN8  
JPG1  
JPB1  
LAN CTRL  
IPMI_LAN  
LAN  
CTRL  
SP1  
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
JBT1  
CPU2  
BIOS  
B1  
A1  
C1  
D1  
CPU1  
JBAT1  
JOH1  
:
O
H
L
E
D
LED2  
JPW5  
FAN4  
JVR1  
JF1 Header Pins  
20 19  
Ground  
NMI  
X
X
3.3 V  
FP PWRLED  
HDD LED  
ID_UID_SW/3/3V Stby  
NIC1 Activity LED  
NIC2 Activity LED  
Red+ (Blue LED Cathode)  
3.3V  
NIC1 Link LED  
NIC2 Link LED  
Blue+ (OH/Fan Fail/  
PWR FaiL/UID LED)  
Power Fail LED  
Reset  
PWR  
Reset Button  
Power Button  
Ground  
Ground  
2
1
2-23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Front Control Panel Pin Definitions  
NMI Button  
NMI Button  
Pin Definitions (JF1)  
The non-maskable interrupt button  
header is located on pins 19 and 20  
of JF1. Refer to the table on the right  
for pin definitions.  
Pin# Definition  
19  
20  
Control  
Ground  
Power LED  
Power LED  
Pin Definitions (JF1)  
The Power LED connection is located  
on pins 15 and 16 of JF1. Refer to the  
table on the right for pin definitions.  
Pin# Definition  
15  
16  
3.3V  
PWR LED  
A. NMI  
USB2/3  
USB0/1  
COM2  
JUIDB  
COM1  
VGA  
USB6  
B. PWR LED  
BMC  
FAN7  
LAN2  
LAN1  
FAN8  
JPG1  
JPB1  
LAN CTRL  
IPMI_LAN  
LAN  
CTRL  
SP1  
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
20 19  
JBT1  
CPU2  
Ground  
X
NMI  
X
A
BIOS  
3.3 V  
FP PWRLED  
HDD LED  
B
B1  
A1  
C1  
D1  
ID_UID_SW/3/3V Stby  
NIC1 Activity LED  
NIC2 Activity LED  
Red+ (Blue LED Cathode)  
3.3V  
CPU1  
NIC1 Link LED  
NIC2 Link LED  
Blue+ (OH/Fan Fail/  
PWR FaiL/UID LED)  
Power Fail LED  
JBAT1  
JOH1  
:
O
H
L
E
D
Reset  
Reset Button  
Power Button  
Ground  
LED2  
JPW5  
FAN4  
Ground  
PWR  
JVR1  
2
1
2-24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
HDD LED  
HDD LED  
Pin Definitions (JF1)  
The HDD LED connection is located  
on pins 13 and 14 of JF1. Attach a  
cable here to indicate HDD activ-  
ity. See the table on the right for pin  
definitions.  
Pin# Definition  
13  
14  
3.3V Standby  
HD Active  
NIC1/NIC2 LED Indicators  
GLAN1/2 LED  
Pin Definitions (JF1)  
The NIC (Network Interface Control-  
ler) LED connection for GLAN port 1 is  
located on pins 11 and 12 of JF1, and  
the LED connection for GLAN Port 2 is  
on pins 9 and 10. Attach the NIC LED  
cables here to display network activity.  
Refer to the table on the right for pin  
definitions.  
Pin# Definition  
9
Vcc  
10  
11  
12  
NIC 2 LED  
Vcc  
NIC 1 LED  
A. HDD LED  
B. NIC1 LED  
C. NIC2 LED  
USB2/3  
USB0/1  
COM2  
JUIDB  
COM1  
VGA  
USB6  
BMC  
FAN7  
LAN2  
LAN1  
FAN8  
JPG1  
JPB1  
LAN CTRL  
IPMI_LAN  
LAN  
CTRL  
SP1  
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
20 19  
JBT1  
CPU2  
Ground  
NMI  
X
X
BIOS  
3.3 V  
FP PWRLED  
B1  
A1  
C1  
D1  
ID_UID_SW/3/3V Stby  
NIC1 Activity LED  
NIC2 Activity LED  
Red+ (Blue LED Cathode)  
3.3V  
A
HDD LED  
CPU1  
NIC1 Link LED  
B
C
NIC2 Link LED  
Blue+ (OH/Fan Fail/  
PWR FaiL/UID LED)  
Power Fail LED  
JBAT1  
JOH1  
Reset  
PWR  
:
O
H
L
E
D
Reset Button  
Power Button  
Ground  
Ground  
LED2  
JPW5  
FAN4  
JVR1  
2
1
2-25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Overheat (OH)/Fan Fail/PWR Fail/  
UID LED  
OH/Fan Fail/ PWR Fail/Blue_UID  
LED Pin Definitions (JF1)  
Pin# Definition  
Connect an LED cable to pins 7 and  
7
Red_LED-Cathode/OH/Fan Fail/  
Power Fail5.5V.SB  
8 of Front Control Panel to use the  
Overheat/Fan Fail/Power Fail and  
8
Blue_UID LED  
UID LED connections. The Red LED  
on pin 7 provides warnings of over-  
heat, fan failure or power failure. The  
Blue LED on pin 8 works as the front  
panel UID LED indicator. The Red  
LED takes precedence over the Blue  
LED by default. Refer to the table on  
the right for pin definitions.  
OH/Fan Fail/PWR Fail  
LED Status (Red LED)  
State  
Off  
Definition  
Normal  
On  
Overheat  
Fan Fail  
Flashing  
Power Fail LED  
PWR Fail LED  
Pin Definitions (JF1)  
The Power Fail LED connection is  
located on pins 5 and 6 of JF1. Re-  
fer to the table on the right for pin  
definitions.  
Pin# Definition  
5
6
3.3V  
PWR Supply Fail  
USB2/3  
USB0/1  
COM2  
A. OH/Fail/PWR Fail LED  
B. PWR Supply Fail  
JUIDB  
COM1  
VGA  
USB6  
BMC  
FAN7  
LAN2  
LAN1  
FAN8  
JPG1  
JPB1  
LAN CTRL  
IPMI_LAN  
LAN  
CTRL  
SP1  
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
20 19  
JBT1  
CPU2  
Ground  
NMI  
X
FP PWRLED  
HDD LED  
X
BIOS  
3.3 V  
B1  
A1  
C1  
D1  
ID_UID_SW/3/3V Stby  
NIC1 Activity LED  
NIC2 Activity LED  
Red+ (Blue LED Cathode)  
3.3V  
CPU1  
NIC1 Link LED  
NIC2 Link LED  
A
Blue+ (OH/Fan Fail/  
PWR FaiL/UID LED)  
B Power Fail LED  
JBAT1  
JOH1  
:
O
H
L
E
D
Reset  
PWR  
Reset Button  
Power Button  
Ground  
LED2  
JPW5  
FAN4  
Ground  
JVR1  
2
1
2-26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
Reset Button  
Reset Button  
Pin Definitions (JF1)  
The Reset Button connection is located  
on pins 3 and 4 of JF1. Attach it to a  
hardware reset switch on the computer  
case. Refer to the table on the right for  
pin definitions.  
Pin# Definition  
3
4
Reset  
Ground  
Power Button  
Power Button  
Pin Definitions (JF1)  
The Power Button connection is located  
on pins 1 and 2 of JF1. Momentarily  
contacting both pins will power on/off  
the system. This button can also be con-  
figured to function as a suspend button  
(with a setting in the BIOS - See Chapter  
4). To turn off the power when the system  
is in suspend mode, press the button for  
4 seconds or longer. Refer to the table on  
the right for pin definitions.  
Pin# Definition  
1
2
Signal  
Ground  
A. Reset Button  
B. PWR Button  
USB2/3  
USB0/1  
COM2  
JUIDB  
COM1  
VGA  
USB6  
BMC  
FAN7  
LAN2  
LAN1  
FAN8  
JPG1  
JPB1  
LAN CTRL  
IPMI_LAN  
LAN  
CTRL  
SP1  
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
20 19  
JBT1  
CPU2  
Ground  
NMI  
X
FP PWRLED  
HDD LED  
X
BIOS  
3.3 V  
B1  
A1  
C1  
D1  
ID_UID_SW/3/3V Stby  
NIC1 Activity LED  
CPU1  
NIC1 Link LED  
NIC2 Activity LED  
NIC2 Link LED  
Blue+ (OH/Fan Fail/  
PWR FaiL/UID LED)  
Red+ (Blue LED Cathode)  
Power Fail LED  
3.3V  
JBAT1  
A
JOH1  
:
O
H
L
E
D
Reset  
Reset Button  
Ground  
LED2  
JPW5  
Power Button  
FAN4  
Ground  
PWR  
JVR1  
2
1
B
2-27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
ATX Power 24-pin Connector  
2-7 Connecting Cables  
Pin Definitions  
Pin# Definition Pin #  
Definition  
+3.3V  
+3.3V  
COM  
Power Connectors  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
+3.3V  
-12V  
1
A 24-pin main power supply connector(JPW1),  
two 8-pin CPU power connectors (JPW2/3)  
and two 4-pin power connectors (JPW4/5) are  
located on the motherboard. These power con-  
nectors meet the SSI EPS 12V specification  
and must be connected to your power supply to  
provide adequate power to the system. See the  
table on the right for pin definitions.  
2
COM  
PS_ON  
COM  
COM  
COM  
Res (NC)  
+5V  
3
4
+5V  
5
COM  
6
+5V  
7
COM  
8
PWR_OK  
5VSB  
+12V  
9
Warning: To avoid damaging your motherboard  
and components, please use a power supply that  
supports a 24-pin, two 4-pin and two 8-pin power  
connectors. Be sure to connect the 24-pin and  
the 8-pin power connectors to your power supply  
for adequate power delivery to your system. The  
4-pin power connectors are optional; however,  
Supermicro recommends that these connectors  
also be plugged in for optimal power delivery.  
+5V  
10  
11  
12  
+5V  
+12V  
COM  
+3.3V  
12V 8-pin PWR Con-  
nector  
Pin Definitions  
Pins  
Definition  
Ground  
+12V  
1 through 4  
5 through 8  
(Required)  
USB2/3  
USB0/1  
COM2  
JUIDB  
COM1  
VGA  
USB6  
A. JPW1: 24-pin ATX  
PWR (Req'd)  
BMC  
FAN7  
LAN2  
LAN1  
FAN8  
JPG1  
JPB1  
LAN CTRL  
IPMI_LAN  
LAN  
CTRL  
SP1  
B. JPW2: 8-pin Processor  
PWR (Req'd)  
JI2C1  
JI2C2  
CLK CTRL  
C. JPW3: 8-pin Processor  
PWR (Req'd)  
D
JPW4  
X9DRD-iF  
Rev. 1.10  
D. JPW4: 4-pin Processor  
PWR (Req'd)  
PCH  
F1  
E1  
G1  
H1  
JBT1  
CPU2  
E. JPW5: 4-pin Processor  
PWR (Req'd)  
BIOS  
B1  
A1  
C1  
D1  
CPU1  
C
JBAT1  
JOH1  
A
L
B
E
LED2  
JPW5  
FAN4  
JVR1  
2-28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
Fan Headers  
Fan Header  
Pin Definitions  
This motherboard has eight system/  
CPU fan headers (FAN 1~FAN 8) on the  
motherboard. All these 4-pin fans head-  
ers are backward compatible with the  
traditional 3-pin fans. However, fan speed  
control is available for 4-pin fans only.  
The fan speeds are controlled by Thermal  
Management via Hardware Monitoring in  
the Advanced Setting in the BIOS. (See  
Chapter 4 for more details.) See the table  
on the right for pin definitions.  
Pin# Definition  
1
2
3
4
Ground  
+12V  
Tachometer  
PWR Modulation  
Note: X9DRD-iF has FAN1~8.  
X9DRD-LF has FAN1~6.  
Chassis Intrusion  
Chassis Intrusion  
Pin Definitions  
A Chassis Intrusion header is located  
at JL1 on the motherboard. Attach an  
appropriate cable from the chassis to  
inform you of a chassis intrusion when  
the chassis is opened.  
Pin# Definition  
1
2
Intrusion Input  
Ground  
USB2/3  
USB0/1  
COM2  
JUIDB  
G
COM1  
A. Fan 1  
H
VGA  
USB6  
BMC  
FAN7  
LAN2  
LAN1  
FAN8  
LAN CTRL  
B. Fan 2  
IPMI_LAN  
JPG1  
JPB1  
LAN  
CTRL  
SP1  
C. Fan 3  
JI2C1  
JI2C2  
CLK CTRL  
D. Fan 4  
JPW4  
E. Fan 5  
X9DRD-iF  
Rev. 1.10  
F. Fan 6  
PCH  
F1  
E1  
G1  
H1  
G. Fan 7  
JBT1  
CPU2  
H. Fan 8  
I. Chassis Intrusion  
BIOS  
B1  
A1  
C1  
D1  
CPU1  
JBAT1  
JOH1  
:
O
H
L
E
D
E
I
D
C
B
A
LED2  
JPW5  
FAN4  
F
JVR1  
2-29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Internal Speaker  
Internal Buzzer (SP1)  
Pin Definition  
The Internal Speaker, located at SP1,  
can be used to provide audible indica-  
tions for various beep codes. See the  
table on the right for pin definitions.  
Refer to the layout below for the loca-  
tions of the Internal Buzzer (SP1).  
Pin#  
Pin 1  
Pin 2  
Definitions  
Beep In  
Pos. (+)  
Neg. (-)  
Alarm  
Speaker  
PWR LED Connector  
Pin Definitions  
Power LED/Speaker  
On JD1 header, pins 1-3 are used for  
power LED indication, and pins 4-7  
are for the speaker. See the tables  
on the right for pin definitions. Please  
note that the speaker connector  
pins (4-7) are used with an external  
speaker. If you wish to use the on-  
board speaker, you should close pins  
6-7 with a jumper.  
Pin Setting Definition  
Pin 1  
Pin2  
Pin3  
Anode (+)  
Cathode (-)  
NA  
Speaker Connector  
Pin Settings  
Pin Setting Definition  
Pins 4-7 External Speaker  
Pins 6-7 Internal Speaker  
A. Internal Speaker  
USB2/3  
USB0/1  
COM2  
JUIDB  
COM1  
VGA  
USB6  
(Buzzer)  
BMC  
A
FAN7  
LAN2  
LAN1  
FAN8  
JPG1  
JPB1  
LAN CTRL  
IPMI_LAN  
B
LAN  
CTRL  
B. PWR LED/Speaker  
SP1  
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
JBT1  
CPU2  
BIOS  
B1  
A1  
C1  
D1  
CPU1  
JBAT1  
JOH1  
:
O
H
L
E
D
LED2  
JPW5  
FAN4  
JVR1  
2-30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
TPM Header/Port 80  
TPM/Port 80 Header  
Pin Definitions  
A Trusted Platform Module/Port 80  
header is located at JTPM1 to provide  
TPM support and Port 80 connection.  
Use this header to enhance system  
performance and data security. See  
the table on the right for pin defini-  
tions.  
Pin #  
1
Definition Pin #  
Definition  
GND  
LCLK  
2
4
6
8
3
LFRAME#  
LRESET#  
LAD 3  
<(KEY)>  
+5V (X)  
5
7
LAD 2  
9
+3.3V  
10  
12  
14  
16  
18  
20  
LAD1  
11  
13  
15  
17  
19  
LAD0  
GND  
SMB_CLK4  
+3V_DUAL  
GND  
SMB_DAT4  
SERIRQ  
CLKRUN# (X)  
LDRQ# (X)  
LPCPD#  
Overheat LED  
Pin Definitions  
Overheat LED/Fan Fail  
The JOH1 header is used to connect  
an LED indicator to provide warnings  
of chassis overheating and fan failure.  
This LED will blink when a fan failure  
occurs. Refer to the tables on right for  
pin definitions.  
Pin# Definition  
1
2
5vDC  
OH Active  
OH/Fan Fail LED  
Status  
State  
Solid  
Message  
Overheat  
Blinking Fan Fail  
USB2/3  
USB0/1  
COM2  
JUIDB  
COM1  
VGA  
USB6  
A. TPM/Port 80 Header  
B. JOH1  
BMC  
FAN7  
LAN2  
LAN1  
FAN8  
JPG1  
JPB1  
LAN CTRL  
IPMI_LAN  
LAN  
CTRL  
SP1  
A
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
JBT1  
CPU2  
BIOS  
B1  
A1  
C1  
D1  
CPU1  
B
JBAT1  
JOH1  
:
O
H
L
E
D
LED2  
JPW5  
FAN4  
JVR1  
2-31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Power SMB (I2C) Connector  
PWR SMB  
Pin Definitions  
Power System Management Bus (I2C)  
Connector (JPI2C1) monitors power  
supply, fan and system temperatures.  
See the table on the right for pin  
definitions.  
Pin# Definition  
1
2
Clock  
Data  
3
4
5
PWR Fail  
Ground  
+3.3V  
IPMB  
IPMB Header  
Pin Definitions  
A System Management Bus header  
for IPMI 2.0 is located at JIPMB1.  
Connect the appropriate cable here  
to use the IPMB I2C connection on  
your system.  
Pin# Definition  
1
2
3
4
Data  
Ground  
Clock  
No Connection  
B
A. JPI2C1  
B. JIPMB1  
USB2/3  
USB0/1  
COM2  
JUIDB  
COM1  
VGA  
USB6  
BMC  
FAN7  
LAN2  
LAN1  
FAN8  
JPG1  
JPB1  
LAN CTRL  
IPMI_LAN  
LAN  
CTRL  
SP1  
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
JBT1  
CPU2  
BIOS  
B1  
A1  
C1  
D1  
CPU1  
JBAT1  
JOH1  
:
O
H
L
E
D
LED2  
JPW5  
FAN4  
A
JVR1  
2-32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
T-SGPIO 1/2 & 3-SGPIO 1 Headers  
(X9DRD-iF)  
T-SGPIO/3-SGPIO  
Pin Definitions  
Pin# Definition  
Pin  
2
Definition  
NC  
Three SGPIO (Serial Link General  
Purpose Input/Output) headers are  
located on the motherboard. T-SGPIO  
1/2 supports onboard SATA and  
3-SGPIO 1 supports SCU Ports 0~3  
on the X9DRD-iF. See the table on  
the right for pin definitions.  
1
3
NC  
Ground  
4
Data  
5
7
Load  
6
8
Ground  
NC  
Clock  
Note: NC= No Connection  
DOM Power Connector (X9DRD-iF)  
DOM PWR  
Pin Definitions  
A power connector for SATA DOM  
(Disk_On_Module) devices is located  
at JSD1. Connect an appropriate  
cable here to provide power support  
for your Serial Link DOM devices.  
Pin# Definition  
1
2
3
+5V  
Ground  
Ground  
USB2/3  
USB0/1  
COM2  
JUIDB  
A. T-SGPIO1 (X9DRD-iF)  
COM1  
VGA  
USB6  
B. T-SGPIO2 (X9DRD-iF)  
C. 3-SGPIO1 (X9DRD-iF)  
D. DOM PWR (X9DRD-iF)  
BMC  
FAN7  
LAN2  
LAN1  
FAN8  
JPG1  
JPB1  
LAN CTRL  
IPMI_LAN  
LAN  
CTRL  
SP1  
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
JBT1  
CPU2  
BIOS  
D
B1  
A1  
C1  
D1  
CPU1  
A
B
JBAT1  
JOH1  
:
O
H
L
E
D
LED2  
JPW5  
C
FAN4  
JVR1  
2-33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Standby Power Header (X9DRD-iF)  
Standby PWR  
Pin Definitions  
The +5V Standby Power header is lo-  
cated at JSTBY1 on the motherboard.  
See the table on the right for pin defini-  
tions. (You must also have a card with  
a Standby Power connector and a cable  
to use this feature.)  
Pin# Definition  
1
2
3
+5V Standby  
Ground  
Wake-up  
USB2/3  
USB0/1  
COM2  
A. Standby PWR (X9DRD-iF)  
JUIDB  
COM1  
VGA  
USB6  
BMC  
FAN7  
LAN2  
LAN1  
FAN8  
JPG1  
JPB1  
LAN CTRL  
IPMI_LAN  
LAN  
CTRL  
SP1  
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
JBT1  
CPU2  
BIOS  
B1  
A1  
C1  
D1  
CPU1  
JBAT1  
JOH1  
:
O
H
L
E
D
LED2  
JPW5  
A
FAN4  
JVR1  
2-34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
2-8 Jumper Settings  
Explanation of Jumpers  
3
2
1
Connector  
Pins  
To modify the operation of the mother-  
board, jumpers can be used to choose  
between optional settings. Jumpers create  
shorts between two pins to change the  
function of the connector. Pin 1 is identified  
with a square solder pad on the printed  
circuit board. See the motherboard layout  
pages for jumper locations.  
Jumper  
Cap  
3
2
1
Setting  
Pin 1-2 short  
Note: On two-pin jumpers,  
"Closed" means the jumper is  
on and "Open" means the jumper  
is off the pins.  
GLAN Enable/Disable  
GLAN Enable  
Jumper Settings  
JPL1 enables or disables the GLAN Port1  
and GLAN Port2 on the motherboard. See  
the table on the right for jumper settings.  
The default setting is Enabled.  
Jumper Setting Definition  
1-2  
2-3  
Enabled (default)  
Disabled  
A. GLAN1 Enable  
B. GLAN2 Enable  
USB2/3  
USB0/1  
COM2  
JUIDB  
COM1  
VGA  
USB6  
BMC  
FAN7  
LAN2  
LAN1  
FAN8  
JPG1  
JPB1  
LAN CTRL  
IPMI_LAN  
LAN  
CTRL  
SP1  
A
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
JBT1  
CPU2  
BIOS  
B1  
A1  
C1  
D1  
CPU1  
JBAT1  
JOH1  
:
O
H
L
E
D
LED2  
JPW5  
FAN4  
JVR1  
2-35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
CMOS Clear  
JBT1 is used to clear CMOS. Instead of pins, this "jumper" consists of contact pads  
to prevent accidental clearing of CMOS. To clear CMOS, use a metal object such  
as a small screwdriver to touch both pads at the same time to short the connection.  
Always remove the AC power cord from the system before clearing CMOS.  
Note 1: For an ATX power supply, you must completely shut down the  
system, remove the AC power cord, and then short JBT1 to clear CMOS.  
Note 2: Be sure to remove the onboard CMOS Battery before you short  
JBT1 to clear CMOS.  
Note 3: Clearing CMOS will also clear all passwords.  
Watch Dog Enable/Disable  
Watch Dog (JWD1) is a system monitor that  
Watch Dog  
will reboot the system when a software ap-  
Jumper Settings  
plication hangs. Close pins 1-2 to reset the  
Jumper Setting Definition  
system if an application hangs. Close pins  
Pins 1-2  
Pins 2-3  
Open  
Reset (default)  
NMI  
2-3 to generate a non-maskable interrupt  
signal for the application that hangs. See the  
table on the right for jumper settings. Watch  
Dog must also be enabled in the BIOS.  
Disabled  
A. Clear CMOS  
B. Watch Dog Enable  
USB2/3  
USB0/1  
COM2  
JUIDB  
COM1  
VGA  
USB6  
BMC  
FAN7  
LAN2  
LAN1  
FAN8  
JPG1  
JPB1  
LAN CTRL  
IPMI_LAN  
LAN  
CTRL  
SP1  
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
JBT1  
A
CPU2  
B
BIOS  
B1  
A1  
C1  
D1  
CPU1  
JBAT1  
JOH1  
:
O
H
L
E
D
LED2  
JPW5  
FAN4  
JVR1  
2-36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
VGA Enable  
VGA Enable  
Jumper Settings  
Jumper JPG1 allows the user to enable  
the onboard VGA connector. The default  
setting is 1-2 to enable the connection.  
See the table on the right for jumper  
settings.  
Jumper Setting Definition  
1-2  
2-3  
Enabled (Default)  
Disabled  
BMC Enable  
BMC Enable  
Jumper Settings  
Jumper JPB1 allows you to enable the  
embedded WPCM 450 BMC (Baseboard  
Management) Controller to provide IPMI  
2.0/KVM support on the motherboard.  
See the table on the right for jumper  
settings.  
Jumper Setting Definition  
Pins 1-2  
BMC Enable  
(Default)  
Pins 2-3  
Normal  
A. VGA Enabled  
B. BMC Enabled  
USB2/3  
USB0/1  
COM2  
JUIDB  
COM1  
VGA  
USB6  
BMC  
LAN2  
LAN1  
FAN8  
LAN CTRL  
IPMI_LAN  
A
JPG1  
JPB1  
LAN  
CTRL  
SP1  
B
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
JBT1  
CPU2  
BIOS  
B1  
A1  
C1  
D1  
CPU1  
JBAT1  
JOH1  
:
O
H
L
E
D
LED2  
JPW5  
FAN4  
JVR1  
2-37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Management Engine (ME) Recovery  
ME Recovery  
Jumper Settings  
Use Jumper JPME1 to select ME Firm-  
ware Recovery mode, which will limit  
resource allocation for essential system  
operation only in order to maintain nor-  
mal power operation and management.  
In the single operation mode, online  
upgrade will be available via Recovery  
mode. See the table on the right for  
jumper settings.  
Jumper Setting Definition  
1-2  
2-3  
Normal (Default)  
ME Recovery  
Manufacture Mode Select (X9DRD-iF)  
ME Mode Select  
Jumper Settings  
Close Pin 2 and Pin 3 of Jumper JPME2  
to bypass SPI flash security and force  
the system to operate in the Manufac-  
ture Mode, allowing the user to flash the  
system firmware from a host server for  
system setting modifications. See the  
table on the right for jumper settings.  
Jumper Setting Definition  
1-2  
2-3  
Normal (Default)  
Manufacture Mode  
USB2/3  
USB0/1  
COM2  
JUIDB  
COM1  
VGA  
USB6  
BMC  
LAN CTRL  
FAN7  
LAN2  
LAN1  
FAN8  
JPG1  
JPB1  
IPMI_LAN  
LAN  
CTRL  
SP1  
A. JPME1  
B. JPME2 (X9DRD-iF)  
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
JBT1  
CPU2  
B
A
BIOS  
B1  
A1  
C1  
D1  
CPU1  
JBAT1  
JOH1  
:
O
H
L
E
D
LED2  
JPW5  
FAN4  
JVR1  
2-38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
I2C Bus to PCI-Exp. Slots  
I2C to PCI-E slots  
Jumper Settings  
Use Jumpers JI2C1 and JI2C2 to connect  
the System Management Bus (I2C) to  
PCI-Express slots in order to improve  
PCI slot performance. These two jump-  
ers are to be set at the same time. The  
default setting is Closed to enable the  
connections. See the table on the right  
for jumper settings.  
Jumper Setting Definition  
Closed  
Open  
Enabled (Default)  
Disabled  
A. JI2C1  
B. JI2C2  
USB2/3  
USB0/1  
COM2  
JUIDB  
COM1  
VGA  
USB6  
BMC  
FAN7  
LAN2  
LAN1  
FAN8  
JPG1  
JPB1  
LAN CTRL  
IPMI_LAN  
LAN  
CTRL  
SP1  
A
B
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
JBT1  
CPU2  
BIOS  
B1  
A1  
C1  
D1  
CPU1  
JBAT1  
JOH1  
:
O
H
L
E
D
LED2  
JPW5  
FAN4  
JVR1  
2-39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
2-9 Onboard LED Indicators  
Link LED  
Activity LED  
GLAN LEDs  
Rear View (when facing the  
rear side of the chassis)  
There are two GLAN ports on the moth-  
erboard. Each Gigabit Ethernet LAN port  
has two LEDs. The Yellow LED on the  
right indicates activity. The Link LED on  
the left side may be green, amber or off to  
indicate the speed of the connection. See  
the table on the right for more information.  
GLAN Activity Indicator (Right)  
LED Settings  
Color  
Status  
Definition  
Yellow  
Flashing  
Active  
GLAN Speed/Link Indicator (Left)  
LED Settings  
LED Color Definition  
Off  
No Connection or 10 Mbps  
100 Mbps  
Green  
Amber  
1 Gbps  
IPMI LAN  
IPMI Dedicated LAN LEDs  
Link LED  
Activity LED  
In addition to LAN 1/LAN 2, an IPMI  
Dedicated LAN is also located on the I/O  
Backplane of the motherboard. The amber  
LED on the right indicates activity, while the  
green LED on the left indicates the speed of  
the connection. See the table on the right  
for more information.  
IPMI LAN Link LED (Left) &  
Activity LED (Right)  
Color/State  
Definition  
100 Mbps  
Link (Left)  
Green: Solid  
Activity (Right) Amber: Blinking Active  
A. LAN1/2 LEDs  
USB2/3  
USB0/1  
COM2  
JUIDB  
COM1  
VGA  
USB6  
BMC  
LAN CTRL  
LAN1  
FAN8  
JPG1  
JPB1  
FAN7  
LAN2  
IPMI_LAN  
B. IPMI LAN LEDs  
LAN  
CTRL  
SP1  
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
JBT1  
CPU2  
BIOS  
B1  
A1  
C1  
D1  
B
CPU1  
A
JBAT1  
JOH1  
:
O
H
L
E
D
LED2  
JPW5  
FAN4  
JVR1  
2-40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Installation  
Onboard Power LED  
Onboard PWR LED Indicator  
LED States  
An Onboard Power LED is located at  
LED2 on the motherboard. When this  
LED is on, the system is on. Be sure to  
turn off the system and unplug the power  
cord before removing or installing compo-  
nents. See the table on the right for more  
information.  
LED Color Definition  
Off  
System Off (PWR cable  
not connected)  
Green  
System On  
Green:  
ACPI S1 State  
Flashing  
Quickly  
BMC Heartbeat LED  
BMC Heartbeat LED  
States  
A BMC Heartbeat LED is located at  
LEDM1 on the motherboard. When  
LEDDM1 is blinking, BMC functions  
normally. See the table on the right for  
more information.  
Color/State  
Definition  
Green:  
Blinking  
BMC: Normal  
B
A. PWR LED  
B. BMC LED  
USB2/3  
USB0/1  
COM2  
JUIDB  
COM1  
VGA  
USB6  
BMC  
FAN7  
LAN2  
LAN1  
FAN8  
JPG1  
JPB1  
LAN CTRL  
IPMI_LAN  
LAN  
CTRL  
SP1  
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
JBT1  
CPU2  
BIOS  
B1  
A1  
C1  
D1  
CPU1  
JBAT1  
H1  
A
:
H
L
E
D
LED2  
JPW5  
FAN4  
JVR1  
2-41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
2-10 SATA/SCU Connections  
SATA Ports/SCU Connectors  
Serial ATA/SCU  
Pin Definitions  
There are four SATA 2.0 Ports (SATA0~SATA3) and  
two SATA 3.0 located on the X9DRD-iF. In addition,  
four SCU Connectors (SCU0~3) are also located on  
the board. These ports provide serial-link signal con-  
nections, which are faster than the connections of Par-  
allel ATA. See the table on the right for pin definitions.  
Pin# Definition  
1
2
3
4
5
6
7
Ground  
TX_P  
TX_N  
Ground  
RX_N  
RX_P  
Ground  
Note 1: X9DRD-LF only has I-SATA0 and I-SATA1.  
Note 2: For more information on SATA HostRAID configuration, please  
refer to the Intel SATA HostRAID User's Guide posted on our website @  
http://www.supermicro.com..  
A. I-SATA0  
USB2/3  
USB0/1  
COM2  
JUIDB  
COM1  
VGA  
USB6  
B. I-SATA1  
C. I-SATA2  
D. I-SATA3  
E. I-SATA4  
F. I-SATA5  
G. SCU0  
H. SCU1  
BMC  
LAN CTRL  
FAN7  
LAN2  
LAN1  
FAN8  
JPG1  
JPB1  
IPMI_LAN  
LAN  
CTRL  
SP1  
JI2C1  
JI2C2  
CLK CTRL  
JPW4  
X9DRD-iF  
Rev. 1.10  
PCH  
F1  
E1  
G1  
H1  
I. SCU2  
JBT1  
CPU2  
J. SCU3  
BIOS  
B
C1  
A
C
E
B1  
A1  
D1  
D
CPU1  
F
H
J
G
I
JBAT1  
JOH1  
:
O
H
L
E
D
LED2  
JPW5  
FAN4  
JVR1  
2-42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Troubleshooting  
Chapter 3  
Troubleshooting  
3-1 Troubleshooting Procedures  
Use the following procedures to troubleshoot your system. If you have followed all  
of the procedures below and still need assistance, refer to the ‘Technical Support  
Procedures’ and/or ‘Returning Merchandise for Service’ section(s) in this chapter.  
Note: Always disconnect the power cord before adding, changing or installing any  
hardware components.  
Before Power On  
1. Make sure that there are no short circuits between the motherboard and  
chassis.  
2. Disconnect all ribbon/wire cables from the motherboard, including those for  
the keyboard and mouse.  
3. Remove all add-on cards.  
4. Install CPU 1 first (making sure it is fully seated) and connect the front panel  
connectors to the motherboard.  
No Power  
1. Make sure that no short circuits between the motherboard and the chassis.  
2. Make sure that the ATX power connectors are properly connected  
3. Check that the 115V/230V switch on the power supply is properly set, if avail-  
able.  
4. Turn the power switch on and off to test the system, if applicable.  
5. The battery on your motherboard may be old. Check to verify that it still sup-  
plies ~3VDC. If it does not, replace it with a new one.  
3-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
No Video  
1. If the power is on, but you have no video, remove all the add-on cards and  
cables.  
2. Use the speaker to determine if any beep codes exist. Refer to Appendix A  
for details on beep codes.  
System Boot Failure  
If the system does not display POST or does not respond after the power is turned  
on, check the following:  
1. Check for any error beep from the motherboard speaker.  
If there is no error beep, try to turn on the system without DIMM modules in-  
stalled. If there is still no error beep, try to turn on the system again with only  
one processor installed in CPU Socket#1. If there is still no error beep, replace  
the motherboard.  
If there are error beeps, clear the CMOS settings by unplugging the power  
cord and contracting both pads on the CMOS Clear Jumper (JBT1). (Refer to  
Section 2-8 in Chapter 2.)  
2. Remove all components from the motherboard, especially the DIMM modules.  
Make sure that system power is on, and memory error beeps are activated.  
3. Turn on the system with only one DIMM module installed. If the system  
boots, check for bad DIMM modules or slots by following the Memory Errors  
Troubleshooting procedure in this Chapter.  
Losing the System’s Setup Configuration  
1. Make sure that you are using a high quality power supply. A poor quality  
power supply may cause the system to lose the CMOS setup information.  
Refer to Section 2-7 for details on recommended power supplies.  
2. The battery on your motherboard may be old. Check to verify that it still sup-  
plies ~3VDC. If it does not, replace it with a new one.  
3. If the above steps do not fix the Setup Configuration problem, contact your  
vendor for repairs.  
3-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Troubleshooting  
Memory Errors  
When a No-Memory Beep Code is issued by the system, check the following:  
1. Make sure that the memory modules are compatible with the system and that  
the DIMM modules are properly and fully installed. (For memory compatibility,  
refer to the Memory Compatibility Chart posted on our website @ http://www.  
supermicro.com.)  
2. Check if different speeds of DIMMs have been installed. It is strongly recom-  
mended that you use the same RAM speed for all DIMMs in the system.  
3. Make sure that you are using the correct type of Registered/Unbuffered ECC  
DDR3 DIMM or LRDIMM modules recommended by the manufacturer.  
4. Check for bad DIMM modules or slots by swapping a single module among  
all memory slots and check the results.  
5. Make sure that all memory modules are fully seated in their slots. Follow the  
instructions given in Section 2-4 in Chapter 2.  
6. Please follow the instructions given in the DIMM Population Tables listed in  
Section 2-4 to install your memory modules.  
When the System Becomes Unstable  
A. The system becomes unstable during or after OS installation  
When the system becomes unstable during or after OS installation, check the fol-  
lowing:  
1. CPU/BIOS support: Make sure that your CPU is supported, and you have the  
latest BIOS installed in your system.  
2. Memory support: Make sure that the memory modules are supported by test-  
ing the modules using memtest86 or a similar utility.  
Note: Refer to the product page on our website http:\\www.supermicro.  
com for memory and CPU support and updates.  
3. HDD support: Make sure that all hard disk drives (HDDs) work properly. Re-  
place the bad HDDs with good ones.  
4. System cooling: Check system cooling to make sure that all heatsink fans,  
and CPU/system fans, etc., work properly. Check Hardware Monitoring set-  
tings in the BIOS to make sure that the CPU and System temperatures are  
3-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
within the normal range. Also check the front panel Overheat LED, and make  
sure that the Overheat LED is not on.  
5. Adequate power supply: Make sure that the power supply provides adequate  
power to the system. Make sure that all power connectors are connected.  
Please refer to our website for more information on minimum power require-  
ment.  
6. Proper software support: Make sure that the correct drivers are used.  
B. The system becomes unstable before or during OS installation  
When the system becomes unstable before or during OS installation, check the  
following:  
1. Source of installation: Make sure that the devices used for installation are  
working properly, including boot devices such as CD/DVD disc, CD/DVD-  
ROM.  
2. Cable connection: Check to make sure that all cables are connected and  
working properly.  
3. Using minimum configuration for troubleshooting: Remove all unnecessary  
components (starting with add-on cards first), and use minimum configuration  
(with a CPU and a memory module installed) to identify the trouble areas.  
Refer to the steps listed in Section A above for proper troubleshooting proce-  
dures.  
4. Identifying bad components by isolating them: If necessary, remove a compo-  
nent in question from the chassis, and test it in isolation to make sure that it  
works properly. Replace a bad component with a good one.  
5. Check and change one component at a time instead of changing several  
items at the same time. This will help isolate and identify the problem.  
6. To nd out if a component is good, swap this component with a new one to  
see if the system will work properly. If so, then the old component is bad.  
You can also install the component in question in another system. If the new  
system works, the component is good and the old system has problems.  
3-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Troubleshooting  
3-2 Technical Support Procedures  
Before contacting Technical Support, please take the following steps. Also, please  
note that as a motherboard manufacturer, Supermicro also sells motherboards  
through its channels, so it is best to first check with your distributor or reseller for  
troubleshooting services. They should know of any possible problem(s) with the  
specific system configuration that was sold to you.  
1. Please go through the ‘Troubleshooting Procedures’ and 'Frequently Asked  
Question' (FAQ) sections in this chapter or see the FAQs on our website  
(http://www.supermicro.com/) before contacting Technical Support.  
2. BIOS upgrades can be downloaded from our website (http://www.supermicro.  
com).  
3. If you still cannot resolve the problem, include the following information when  
contacting Supermicro for technical support:  
Motherboard model and PCB revision number  
BIOS release date/version (This can be seen on the initial display when your  
system first boots up.)  
System configuration  
4. An example of a Technical Support form is on our website at (http://www.  
supermicro.com).  
Distributors: For immediate assistance, please have your account number ready  
when placing a call to our technical support department. We can be reached by  
e-mail at [email protected].  
3-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
3-3 Battery Removal and Installation  
Battery Removal  
To remove the onboard battery, follow the steps below:  
1. Power off your system and unplug your power cable.  
2. Locate the onboard battery as shown below.  
3. Using a tool such as a pen or a small screwdriver, push the battery lock out-  
wards to unlock it. Once unlocked, the battery will pop out from the holder.  
4. Remove the battery.  
Proper Battery Disposal  
Warning: Please handle used batteries carefully. Do not damage the battery in any  
way; a damaged battery may release hazardous materials into the environment. Do  
not discard a used battery in the garbage or a public landfill. Please comply with the  
regulations set up by your local hazardous waste management agency to dispose of  
your used battery properly.  
Battery Installation  
1. To install an onboard battery, follow the steps 1 & 2 above and continue  
below:  
2. Identify the battery's polarity. The positive (+) side should be facing up.  
3. Insert the battery into the battery holder and push it down until you hear a  
click to ensure that the battery is securely locked.  
Warning: When replacing a battery, be sure to only replace it with the same type.  
OR  
3-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Troubleshooting  
3-4 Frequently Asked Questions  
Question: What are the various types of memory that my motherboard can  
support?  
Answer: The motherboard supports Registered/Unbuffered ECC DDR3 DIMM or  
LRDIMM modules. To enhance memory performance, do not mix memory modules  
of different speeds and sizes. Please follow all memory installation instructions given  
on Section 2-4 in Chapter 2.  
Question: How do I update my BIOS?  
It is recommended that you do not upgrade your BIOS if you are not experiencing  
any problems with your system. Updated BIOS files are located on our website  
at http://www.supermicro.com. Please check our BIOS warning message and the  
information on how to update your BIOS on our website. Select your motherboard  
model and download the BIOS file to your computer. Also, check the current BIOS  
revision to make sure that it is newer than your BIOS before downloading. You can  
choose from the zip file and the .exe file. If you choose the zip BIOS file, please  
unzip the BIOS file onto a bootable USB device. Run the batch file using the format  
AMI.bat filename.rom from your bootable USB device to flash the BIOS. Then, your  
system will automatically reboot.  
Warning: Do not shut down or reset the system while updating the BIOS to prevent  
possible system boot failure!)  
Note: The SPI BIOS chip used on this motherboard cannot be removed.  
Send your motherboard back to our RMA Department at Supermicro for  
repair. For BIOS Recovery instructions, please refer to the AMI BIOS  
Recovery Instructions posted at http://www.supermicro.com.  
Question: How do I handle the used battery?  
Answer: Please handle used batteries carefully. Do not damage the battery in any  
way; a damaged battery may release hazardous materials into the environment. Do  
not discard a used battery in the garbage or a public landfill. Please comply with the  
regulations set up by your local hazardous waste management agency to dispose  
of your used battery properly. (Refer to Section 3-3 on Page 3-6.)  
3-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
3-5 Returning Merchandise for Service  
A receipt or copy of your invoice marked with the date of purchase is required before  
any warranty service will be rendered. You can obtain service by calling your ven-  
dor for a Returned Merchandise Authorization (RMA) number. When returning the  
motherboard to the manufacturer, the RMA number should be prominently displayed  
on the outside of the shipping carton, and the shipping package is mailed prepaid  
or hand-carried. Shipping and handling charges will be applied for all orders that  
must be mailed when service is complete. For faster service, you can also request  
a RMA authorization online (http://www.supermicro.com/RmaForm/).  
This warranty only covers normal consumer use and does not cover damages in-  
curred in shipping or from failure due to the alternation, misuse, abuse or improper  
maintenance of products.  
During the warranty period, contact your distributor first for any product problems.  
3-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: AMI BIOS  
Chapter 4  
BIOS  
4-1 Introduction  
This chapter describes the AMI BIOS Setup utility for the X9DRD-iF/LF. It also  
provides the instructions on how to navigate the AMI BIOS Setup utility screens.  
The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated.  
Starting BIOS Setup Utility  
To enter the AMI BIOS Setup utility screens, press the <Del> key while the system  
is booting up.  
Note: In most cases, the <Del> key is used to invoke the AMI BIOS setup  
screen. There are a few cases when other keys are used, such as <F3>,  
<F4>, etc.  
Each main BIOS menu option is described in this manual. The Main BIOS setup  
menu screen has two main frames. The left frame displays all the options that can  
be configured. Grayed-out options cannot be configured. Options in blue can be  
configured by the user. The right frame displays the key legend. Above the key  
legend is an area reserved for a text message. When an option is selected in the  
left frame, it is highlighted in white. Often a text message will accompany it.  
Note: The AMI BIOS has default text messages built in. The manufacturer  
retains the option to include, omit, or change any of these text mes-  
sages.  
The AMI BIOS Setup utility uses a key-based navigation system called "hot keys."  
Most of the AMI BIOS setup utility "hot keys" can be used at any time during setup  
navigation. These keys include <F3>, <F4>, <Enter>, <ESC>, arrow keys, etc.  
Note 1: Options printed in Bold are default settings.  
Note 2: <F3> is used to load optimal default settings. <F4> is used to save  
the settings and exit the setup utility.  
How To Change the Configuration Data  
The configuration data that determines the system parameters may be changed by  
entering the AMI BIOS Setup utility. This Setup utility can be accessed by pressing  
<F2> at the appropriate time during system boot.  
4-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Note: For AMI UEFI BIOS Recovery, please refer to the UEFI BIOS Recov-  
ery User Guide posted @ http://www.supermicro.com/support/manuals/.  
Starting the Setup Utility  
Normally, the only visible Power-On Self-Test (POST) routine is the memory test.  
As the memory is being tested, press the <F2> key to enter the main menu of  
the AMI BIOS Setup utility. From the main menu, you can access the other setup  
screens. An AMI BIOS identification string is displayed at the left bottom corner of  
the screen below the copyright message.  
Warning: Do not upgrade the BIOS unless your system has a BIOS-related issue.  
Flashing the wrong BIOS can cause irreparable damage to the system. In no event  
shall the manufacturer be liable for direct, indirect, special, incidental, or consequential  
damage arising from a BIOS update. If you have to update the BIOS, do not shut down  
or reset the system while the BIOS is being updated to avoid possible boot failure.  
4-2 Main Setup  
When you first enter the AMI BIOS Setup utility, you will enter the Main setup screen.  
You can always return to the Main setup screen by selecting the Main tab on the  
top of the screen. The Main BIOS Setup screen is shown below.  
The AMI BIOS main menu displays the following information:  
4-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: AMI BIOS  
System Date  
This item displays the system date in Day MM/DD/YY format (e.g. Wed 10/12/2011).  
System Time  
This item displays the system time in HH:MM:SS format (e.g. 15:32:52).  
Supermicro X9DRD-iF series  
Version  
This item displays the SMC version of the BIOS ROM used in this system.  
Build Date  
This item displays the date that the BIOS Setup utility was built.  
Memory Information  
Total Memory  
This displays the amount of memory that is available in the system.  
4-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
4-3 Advanced Setup Configurations  
Use the arrow keys to select Advanced Setup and press <Enter> to access the  
following submenu items.  
Boot Features  
Quiet Boot  
This feature allows the user to select bootup screen display between POST mes-  
sages and the OEM logo. Select Disabled to display the POST messages. Select  
Enabled to display the OEM logo instead of the normal POST messages. The op-  
tions are Enabled and Disabled.  
AddOn ROM Display Mode  
Use this item to set the display mode for the Option ROM. Select Keep Current to  
use the current AddOn ROM Display setting. Select Force BIOS to use the Option  
ROM display mode set by the system BIOS. The options are Force BIOS and  
Keep Current.  
Bootup Num-Lock  
Use this feature to set the Power-on state for the Numlock key. The options are  
Off and On.  
Wait For 'F1' If Error  
Select Enabled to force the system to wait until the 'F1' key is pressed if an error  
occurs. The options are Disabled and Enabled.  
4-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: AMI BIOS  
Interrupt 19 Capture  
Interrupt 19 is the software interrupt that handles the boot disk function. When this  
item is set to Enabled, the ROM BIOS of the host adaptors will "capture" Interrupt 19  
at bootup and allow the drives that are attached to these host adaptors to function  
as bootable disks. If this item is set to Disabled, the ROM BIOS of the host adap-  
tors will not capture Interrupt 19, and the drives attached to these adaptors will not  
function as bootable devices. The options are Enabled and Disabled.  
Power Configuration  
Watch Dog Function  
If enabled, the Watch Dog timer will allow the system to reboot when it is inactive  
for more than 5 minutes. The options are Enabled and Disabled.  
Power Button Function  
If this feature is set to Instant Off, the system will power off immediately as soon  
as the user presses the power button. If this feature is set to 4 Seconds Override,  
the system will power off when the user presses the power button for 4 seconds or  
longer. The options are Instant Off and 4 Seconds Override.  
Restore on AC Power Loss  
Use this feature to set the power state after a power outage. Select Power-Off for  
the system power to remain off after a power loss. Select Power-On for the system  
power to be turned on after a power loss. Select Last State to allow the system  
to resume its last state before a power loss. The options are Power On, Stay Off  
and Last State.  
CPU Configuration  
This submenu displays the information of the CPU as detected by the BIOS. It also  
allows the user to configuration CPU settings.  
Socket 1 CPU Information/Socket 2 CPU Information  
This submenu displays the following information regarding the CPUs installed  
in Socket 1/ Socket 2.  
Type of CPU  
CPU Signature  
Microcode Patch  
4-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
CPU Stepping  
Maximum CPU Speed  
Minimum CPU Speed  
Processor Cores  
Intel HT (Hyper-Threading) Technology  
Intel VT-x Technology  
Intel SMX Technology  
L1 Data Cache  
L1 Code Cache  
L2 Cache  
L3 Cache  
CPU Speed  
This item displays the speed of the CPU installed in Socket 1/Socket 2.  
64-bit  
This item indicates if the CPU installed in Socket 1 or Socket 2 supports 64-bit  
technology.  
Clock Spread Spectrum  
Select Enable to enable Clock Spectrum support, which will allow the BIOS to moni-  
tor and attempt to reduce the level of Electromagnetic Interference caused by the  
components whenever needed. The options are Disabled and Enabled.  
Hyper-threading  
Select Enabled to support Intel Hyper-threading Technology to enhance CPU per-  
formance. The options are Enabled and Disabled.  
Active Processor Cores  
Set to Enabled to use a processor's second core and above. (Please refer to Intel's  
website for more information.) The options are All, 1, 2, and 4.  
4-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: AMI BIOS  
Limit CPUID Maximum  
This feature allows the user to set the maximum CPU ID value. Enable this function  
to boot the legacy operating systems that cannot support processors with extended  
CPUID functions. The options are Enabled and Disabled (for the Windows OS).  
Execute-Disable Bit (Available if supported by the OS & the CPU)  
Select Enabled to enable the Execute Disable Bit which will allow the processor  
to designate areas in the system memory where an application code can execute  
and where it cannot, thus preventing a worm or a virus from flooding illegal codes  
to overwhelm the processor or damage the system during an attack. The default is  
Enabled. (Refer to Intel and Microsoft Web sites for more information.)  
Intel® AES-NI  
Select Enable to use the Intel Advanced Encryption Standard (AES) New Instruc-  
tions (NI) to ensure data security. The options are Enabled and Disabled.  
Hardware Prefetcher (Available when supported by the CPU)  
If set to Enabled, the hardware prefetcher will prefetch streams of data and instruc-  
tions from the main memory to the L2 cache to improve CPU performance. The  
options are Disabled and Enabled.  
Adjacent Cache Line Prefetch (Available when supported by the CPU)  
The CPU prefetches the cache line for 64 bytes if this feature is set to Disabled.  
The CPU prefetches both cache lines for 128 bytes as comprised if this feature is  
set to Enabled.  
DCU Streamer Prefetcher (Available when supported by the CPU)  
Select Enabled to support Data Cache Unite (DCU) prefetch to speed up data  
accessing and processing in the DCU to enhance CPU performance. The options  
are Disabled and Enabled.  
DCU IP Prefetcher  
Select Enabled for DCU (Data Cache Unit) IP Prefetcher support, which will prefetch  
IP addresses to improve network connectivity and system performance. The options  
are Enabled and Disabled.  
4-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Intel® Virtualization Technology (Available when supported by the CPU)  
Select Enabled to support Intel Virtualization Technology, which will allow one  
platform to run multiple operating systems and applications in independent parti-  
tions, creating multiple "virtual" systems in one physical computer. The options  
are Enabled and Disabled.  
Note: If there is any change to this setting, you will need to power off and  
restart the system for the change to take effect. Please refer to Intel’s  
website for detailed information.)  
CPU Power Management Configuration  
This submenu allows the user to configure the following CPU Power Management  
settings.  
Power Technology  
Select Energy Efficiency to support power-saving mode. Select Custom to cus-  
tomize system power settings. Select Disabled to disable power-saving settings.  
The options are Disabled, Energy Efficiency, and Custom. If the option is set  
to Custom, the following items will display:  
EIST (Available when Power Technology is set to Custom)  
EIST (Enhanced Intel SpeedStep Technology) allows the system to au-  
tomatically adjust processor voltage and core frequency to reduce power  
consumption and heat dissipation. The options are Disabled (GV3 Disabled),  
and Enabled (GV3 Enabled). (Note: GV3 is Intel Speedstep support used  
on older platforms.)Please refer to Intel’s website for detailed information.)  
Turbo Mode (Available when Power Technology is set to Custom)  
Select Enabled to use the Turbo Mode to boost system performance. The  
options are Enabled and Disabled.  
C1E (Available when Power Technology is set to Custom)  
Select Enabled to enable Enhanced C1 Power State to boost system per-  
formance. The options are Enabled and Disabled.  
CPU C3 Report (Available when Power Technology is set to Custom)  
Select Enabled to allow the BIOS to report the CPU C3 State (ACPI C2) to  
the operating system. During the CPU C3 State, the CPU clock generator  
is turned off. The options are Enabled and Disabled.  
4-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: AMI BIOS  
CPU C6 Report (Available when Power Technology is set to Custom)  
Select Enabled to allow the BIOS to report the CPU C6 State (ACPI C3) to  
the operating system. During the CPU C6 State, the power to all cache is  
turned off. The options are Enabled and Disabled.  
CPU C7 Report (Available when Power Technology is set to Custom)  
Select Enabled to allow the BIOS to report the CPU C7 State (ACPI C3) to  
the operating system. CPU C7 State is a processor-specific low C-State.  
The options are Enabled and Disabled.  
Package C-State limit (Available when Power Technology is set to  
Custom)  
This feature allows the user to set the limit on the C-State package register.  
The options are C0, C2, C6, and No Limit.  
Energy Performance  
This setting allows the user to adjust the fan speed based on performance (maxi-  
mum cooling) or energy efficiency (maximum energy savings). The options are  
Performance, Balanced Performance, Balanced Energy, and Energy Efficient.  
Factory Long Duration Power Limit  
This item displays the power limit set by the manufacturer during which long  
duration power is maintained.  
Long Duration Power Limit  
This item displays the power limit set by the manufacturer during which long  
duration power is maintained.  
Factory Long Duration Maintained (Available when Power Technology is  
set to Custom)  
This item displays the period of time set by the manufacturer during which long  
duration power is maintained.  
Long Duration Maintained  
This item displays the period of time during which long duration power is main-  
tained.  
Recommended Short Duration Power  
This item displays the short duration power settings recommended by the  
manufacturer.  
4-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Short Duration Power Limit  
This item displays the time period during which short duration power is main-  
tained.  
Chipset Configuration  
North Bridge  
This feature allows the user to configure the settings for the Intel North Bridge.  
Integrated IO Configuration  
Intel VT-d  
Select Enabled to enable Intel Virtualization Technology support for Direct I/O  
VT-d by reporting the I/O device assignments to the VWM (Virtual Working  
Memory) through the DMAR ACPI Tables. This feature offers fully-protected  
I/O resource sharing across Intel platforms, providing greater reliability, security  
and availability in networking and data-sharing. The options are Enabled and  
Disabled.  
Intel I/OAT  
The Intel I/OAT (I/O Acceleration Technology) significantly reduces CPU over-  
head by leveraging CPU architectural improvements, freeing the system resource  
for other tasks. The options are Disabled and Enabled.  
DCA Support  
Select Enabled to use Intel's DCA (Direct Cache Access) Technology to improve  
data transfer efficiency. The options are Enabled and Disabled.  
IIO 1 PCIe Port Bifurcation Control  
This submenu configures the following IO PCIe Port Bifurcation Control settings  
for IIO 1 PCIe ports to determine how the available PCI-Express lanes to be  
distributed between the PCI-Exp. Root Ports.  
CPU1 Slot3 PCI-E 3.0 x8 Link Speed  
This feature allows the user to set the PCI-Exp bus speed for the slot specified  
above. The options are Gen1 (Generation 1), Gen2 and Gen3.  
CPU1 Slot4 PCI-E 3.0 x8 Link Speed  
This feature allows the user to set the PCI-Exp bus speed for the slot specified  
above. The options are Gen1 (Generation 1), Gen2 and Gen3.  
4-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: AMI BIOS  
CPU1 Slot5 PCI-E 3.0 x8 Link Speed  
This feature allows the user to set the PCI-Exp bus speed for the slot specified  
above. The options are Gen1 (Generation 1), Gen2 and Gen3.  
IIO 2 PCIe Port Bifurcation Control  
This submenu configures the following IO PCIe Port Bifurcation Control settings  
for IIO 2 PCIe ports to determine how the available PCI-Express lanes to be  
distributed between the PCI-Exp. Root Ports.  
QPI Configuration  
Current QPI Link  
This item displays the current status of the QPI Link.  
Current QPI Frequency  
This item displays the frequency of the QPI Link.  
Isoc  
Select Enabled to enable Ischronous support to meet QoS (Quality of Service)  
requirements. This feature is especially important for virtualization technology.  
The options are Enabled and Disabled.  
QPI (Quick Path Interconnect) Link Speed Mode  
Use this feature to select data transfer speed for QPI Link connections. The  
options are Fast and Slow.  
QPI Link Frequency Select  
Use this feature to select the desired QPI frequency. The options are Auto, 6.4  
GT/s, 7.2 GT/s, and 8.0 GT/s.  
DIMM Configuration  
This section displays the following DIMM information.  
Current Memory Mode  
This item displays the current memory mode.  
Current Memory Speed  
This item displays the current memory speed.  
4-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Mirroring  
This item displays if memory mirroring is supported by the motherboard. Memory  
mirroring creates a duplicate copy of the data stored in the memory to enhance  
data security.  
Sparing  
This item displays if memory sparing is supported by the motherboard. Memory  
sparing enhances system performance.  
DIMM Information  
The status of the memory modules specified above will be displayed as detected  
by the BIOS.  
Memory Mode  
When Independent is selected, all DIMMs are available to the operating system.  
The only option is Independent.  
DRAM RAPL Mode  
RAPL (Running Average Power Limit) provides mechanisms to enforce power  
consumption limits on supported processors The options are DRAM RAPL  
MODE0 , DRAM RAPL MODE1, and Disabled.  
DDR Speed  
Use this feature to force a DDR3 memory module to run at a frequency other  
than what is specified in the specification. The options are Auto, Force DDR3-  
800, Force DDR3-1066, Force DDR3-1333, Force DDR3-1600 and Force SPD.  
Channel Interleaving  
This feature selects from the different channel interleaving methods. The options  
are Auto, 1 Way, 2 Way, 3, Way, and 4 Way.  
Rank Interleaving  
This feature allows the user to select a rank memory interleaving method. The  
options are Auto, 1 Way, 2 Way, 4, Way, and 8 Way.  
Patrol Scrub  
Patrol Scrubbing is a process that allows the CPU to correct correctable memory  
errors detected on a memory module and send the correction to the requestor  
(the original source). When this item is set to Enabled, the IO hub will read and  
write back one cache line every 16K cycles, if there is no delay caused by internal  
processing. By using this method, roughly 64 GB of memory behind the IO hub  
will be scrubbed every day. The options are Enabled and Disabled.  
4-12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: AMI BIOS  
Demand Scrub  
Demand Scrubbing is a process that allows the CPU to correct correctable  
memory errors found on a memory module. When the CPU or I/O issues a  
demand-read command, and the read data from memory turns out to be a  
correctable error, the error is corrected and sent to the requestor (the original  
source). Memory is updated as well. Select Enabled to use Demand Scrubbing  
for ECC memory correction. The options are Enabled and Disabled.  
Data Scrambling  
Select Enabled to enable data scrubbing to ensure data security and integrity.  
The options are Disabled and Enabled.  
Device Tagging  
Select Enabled to support device tagging. The options are Disabled and En-  
abled.  
Thermal Throttling  
Throttling improves reliability and reduces power consumption in the proces-  
sor via automatic voltage control during processor idle states. The options are  
Disabled and CLTT (Closed Loop Thermal Throttling).  
South Bridge Configuration  
This feature allows the user to configure the settings for the Intel PCH chip.  
PCH Information  
This feature displays the following PCH information.  
Name: This item displays the name of the PCH chip.  
Stepping: This item displays the status of the PCH stepping.  
USB Devices: This item displays the USB devices detected by the BIOS.  
All USB Devices  
This feature enables all USB ports/devices. The options are Disabled and Enabled.  
(If set to Enabled, EHCI Controller 1 and Controller 2 will appear.)  
EHCI Controller 1/EHCI Controller 2 (Available when All USB Devices is set  
to Enabled)  
Select Enabled to enable EHCI (Enhanced Host Controller Interface) Controller 1  
or Controller 2. The options are Disabled and Enabled.  
4-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Legacy USB Support (Available when USB Functions is not Disabled)  
Select Enabled to support legacy USB devices. Select Auto to disable legacy sup-  
port if USB devices are not present. Select Disable to have USB devices available  
for EFI (Extensive Firmware Interface) applications only. The settings are Disabled,  
Enabled and Auto.  
Port 60/64 Emulation  
Select Enabled to enable I/O port 60h/64h emulation support for the legacy USB  
keyboard so that it can be fully supported by the operating systems that does not  
recognize a USB device. The options are Disabled and Enabled.  
EHCI Hand-Off  
This item is for operating systems that do not support Enhanced Host Controller  
Interface (EHCI) hand-off. When enabled, EHCI ownership change will be claimed  
by the EHCI driver. The options are Disabled and Enabled.  
SATA Configuration  
When this submenu is selected, the AMI BIOS automatically detects the presence  
of IDE or SATA devices and displays the following items.  
SATA Port0~SATA Port5: The AMI BIOS displays the status of each SATA port  
as detected by the BIOS.  
SATA Mode  
Use this feature to configure SATA mode for a selected SATA port. The options are  
Disabled, IDE Mode, AHCI Mode and RAID Mode. The following are displayed  
depending on your selection:  
IDE Mode  
The following items are displayed when IDE Mode is selected:  
SATA (Serial-ATA) Controller 0~1  
Use this feature to activate or deactivate the SATA controller, and set the  
compatibility mode. The options for Controller 0 are Enhanced and Compat-  
ible. The default for SATA Controller 0 is Compatible. The default of SATA  
Controller 1 is Enhanced.  
AHCI Mode  
The following items are displayed when the AHCI Mode is selected.  
4-14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: AMI BIOS  
Aggressive Link Power Management  
Select Enabled to enable Aggressive Link Power Management support  
for Cougar Point B0 stepping and beyond. The options are Enabled and  
Disabled.  
Port 0~5 Hot Plug  
Select Enabled to enable hot-plug support for a particular port, which will  
allow the user to change a hardware component or device without shutting  
down the system. The options are Enabled and Disabled.  
Staggered Spin Up  
Select Enabled to enable Staggered Spin-up support to prevent excessive  
power consumption caused by multiple HDDs spinning-up simultaneously.  
The options are Enabled and Disabled.  
RAID Mode  
The following items are displayed when RAID Mode is selected:  
Port 0~5 Hot Plug  
Select Enabled to enable hot-plug support for the particular port. The options  
are Enabled and Disabled.  
SCU (Storage Control Unit) Configuration  
Storage Controller Unit  
Select Enabled to enable PCH SCU storage devices. The options are Disabled  
and Enabled.  
OnChip SCU Option ROM  
Select Enabled to support the onboard SCU Option ROM to boot up the system via  
a storage device. The options are Disabled and Enabled.  
SCU Port 0~SCU Port 3: The AMI BIOS will automatically detect the onboard SCU  
devices and display the status of each SCU device as detected.  
4-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
PCIe/PCI/PnP Configuration  
PCI ROM Priority  
Use this feature to select the Option ROM to boot the system when there are mul-  
tiple Option ROMs available in the system. The options are EFI Compatible ROM  
and Legacy ROM.  
PCI Latency Timer  
Use this feature to set the latency Timer of each PCI device installed on a PCI bus.  
Select 64 to set the PCI latency to 64 PCI clock cycles. The options are 32, 64, 96,  
128, 160, 192, 224 and 248.  
Above 4G Decoding (Available if the system supports 64-bit PCI decoding)  
Select Enabled to decode a PCI device that supports 64-bit in the space above 4G  
Address. The options are Enabled and Disabled.  
PERR# Generation  
Select Enabled to allow a PCI device to generate a PERR number for a PCI Bus  
Signal Error Event. The options are Enabled and Disabled.  
SERR# Generation  
Select Enabled to allow a PCI device to generate an SERR number for a PCI Bus  
Signal Error Event. The options are Enabled and Disabled.  
Maximum Payload  
Select Auto to allow the system BIOS to automatically set the maximum payload  
value for a PCI-E device to enhance system performance. The options are Auto,  
128 Bytes and 256 Bytes.  
Maximum Read Request  
Select Auto to allow the system BIOS to automatically set the maximum Read  
Request size for a PCI-E device to enhance system performance. The options are  
Auto, 128 Bytes, 256 Bytes, 512 Bytes, 1024 Bytes, 2048 Bytes, and 4096 Bytes.  
ASPM Support  
This feature allows the user to set the Active State Power Management (ASPM)  
level for a PCI-E device. Select Force L0 to force all PCI-E links to operate at L0  
state. Select Auto to allow the system BIOS to automatically set the ASPM level for  
the system. Select Disabled to disable ASPM support. The options are Disabled,  
Force L0, and Auto.  
Warning: Enabling ASPM support may cause some PCI-E devices to fail!  
4-16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: AMI BIOS  
CPU1 Slot 3 PCI-E 3.0 x8 OPROM/CPU1 Slot 4 PCI-E 3.0 x8 OPROM/CPU1  
Slot 5 PCI-E 3.0 x8 OPROM/CPU2 Slot 6 PCI-E 3.0 x16 OPROM/CPU2 Slot 7  
PCI-E 3.0 x8 OPROM  
Select Enabled to enable Option ROM support to boot the computer using a  
network interface from the slots specified above. The options are Enabled and  
Disabled.  
Onboard LAN Option ROM Select  
Select iSCSI to use the iSCSI Option ROM to boot the computer using a network  
device. Select PXE (Preboot Execution Environment) to use an PXE Option ROM  
to boot the computer using a network device. The options are iSCSI and PXE.  
Load Onboard LAN1 Option ROM/Load Onboard LAN2 Option ROM  
Select Enabled to enable the onboard LAN1 Option ROM and LAN2 Option  
ROM. This is to boot the computer using a network device. The default setting for  
LAN1 Option ROM is Enabled, and the default settings for LAN2 Option ROM  
is Disabled.  
VGA Priority  
This feature allows the user to select the graphics adapter to be used as the primary  
boot device. The options are Onboard, and Offboard.  
Network Stack  
Select Enabled enable PXE (Preboot Execution Environment) or UEFI (Unified  
Extensible Firmware Interface) for network stack support. The options are Enabled  
and Disabled.  
Super IO Configuration  
Super IO Chip: This item displays the Super IO chip used in the motherboard.  
Serial Port 1 Configuration  
Serial Port  
Select Enabled to enable a serial port specified by the user. The options are En-  
abled and Disabled.  
Device Settings  
This item displays the settings of Serial Port 1.  
4-17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Change Settings  
Use this feature to set the optimal Environment_Control_Interface (PECI) setting for  
a serial port specified. The default setting is Auto, which will allow the AMI BIOS  
to automatically select the best setting for the PECI platform.  
Device Mode  
Use this feature to select the desired mode for a serial port specified. The options  
are Normal and High Speed.  
Serial Port 2 Configuration  
Serial Port  
Select Enabled to enable a serial port specified by the user. The options are En-  
abled and Disabled.  
Device Settings  
This item displays the settings of Serial Port 2.  
Change Settings  
Use this feature to set the optimal Environment_Control_Interface (PECI) setting for  
a serial port specified. The default setting is Auto, which will allow the AMI BIOS  
to automatically select the best setting for the PECI platform.  
Device Mode  
Use this feature to select the desired mode for a serial port specified. The options  
are Normal and High Speed.  
Serial Port 2 Attribute  
Use this feature to select the attribute for serial port 2. The options are SOL (Serial  
On LAN), and COM.  
Serial Port Console Redirection  
COM1, COM2/SOL  
These two submenus allow the user to configure the following Console Redirection  
settings for a COM Port specified by the user.  
Console Redirection  
Select Enabled to use a COM Port selected by the user for Console Redirection.  
The options are Enabled and Disabled. The default setting for COM1 is Disabled,  
and for COM2 is Enabled.  
4-18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: AMI BIOS  
Console Redirection Settings  
This feature allows the user to specify how the host computer will exchange data  
with the client computer, which is the remote computer used by the user.  
Terminal Type  
This feature allows the user to select the target terminal emulation type for Con-  
sole Redirection. Select VT100 to use the ASCII Character set. Select VT100+ to  
add color and function key support. Select ANSI to use the Extended ASCII Char-  
acter Set. Select VT-UTF8 to use UTF8 encoding to map Unicode characters  
into one or more bytes. The options are ANSI, VT100, VT100+, and VT-UTF8.  
Bits Per second  
Use this feature to set the transmission speed for a serial port used in Console  
Redirection. Make sure that the same speed is used in the host computer and the  
client computer. A lower transmission speed may be required for long and busy  
lines. The options are 9600, 19200, 38400, 57600 and 115200 (bits per second).  
Data Bits  
Use this feature to set the data transmission size for Console Redirection. The  
options are 7 Bits and 8 Bits.  
Parity  
A parity bit can be sent along with regular data bits to detect data transmission  
errors. Select Even if the parity bit is set to 0, and the number of 1's in data bits  
is even. Select Odd if the parity bit is set to 0, and the number of 1's in data bits  
is odd. Select None if you do not want to send a parity bit with your data bits  
in transmission. Select Mark to add a mark as a parity bit to be sent along with  
the data bits. Select Space to add a Space as a parity bit to be sent with your  
data bits. The options are None, Even, Odd, Mark and Space.  
Stop Bits  
A stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard  
serial data communication. Select 2 Stop Bits if slower devices are used. The  
options are 1 and 2.  
Flow Control  
This feature allows the user to set the flow control for Console Redirection to  
prevent data loss caused by buffer overflow. Send a "Stop" signal to stop send-  
ing data when the receiving buffer is full. Send a "Start" signal to start sending  
data when the receiving buffer is empty. The options are None and Hardware  
RTS/CTS.  
4-19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
VT-UTF8 Combo Key Support  
Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100  
terminals. The options are Enabled and Disabled.  
Recorder Mode  
Select Enabled to capture the data displayed on a terminal and send it as text  
messages to a remote server. The options are Disabled and Enabled.  
Resolution 100x31  
Select Enabled for extended-terminal resolution support. The options are Dis-  
abled and Enabled.  
Legacy OS Redirection Resolution  
Use this feature to select the number of rows and columns used in Console  
Redirection for legacy OS support. The options are 80x24 and 80x25.  
Putty KeyPad  
This feature selects Function Keys and KeyPad settings for Putty, which is a  
terminal emulator designed for the Windows OS. The options are VT100, Linux,  
XTERMR6, SC0, ESCN, and VT400.  
Serial Port for Out-of-Band Management/Windows Emergency  
Management Services (EMS)  
The submenu allows the user to configure Console Redirection settings to sup-  
port Out-of-Band Serial Port management.  
Out-of-Band Management Port  
The feature selects a serial port used by the Microsoft Windows Emergency  
Management Services (EMS) to communicate with a remote server.  
ACPI Setting  
Use this feature to configure Advanced Configuration and Power Interface (ACPI)  
power management settings for your system.  
ACPI Sleep State  
Use this feature to select the ACPI State when the system is in sleep mode. Select  
S1 (CPU_Stop_Clock) to erase all CPU caches and stop executing instructions.  
Power to the CPU(s) and RAM is maintained, but RAM is refreshed. Select Suspend  
to use power-reduced mode. Power will only be supplied to limited components  
(such as RAMs) to maintain the most critical functions of the system. The options  
are S1 (CPU_Stop_Clock), Suspend and Disabled.  
4-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: AMI BIOS  
High Precision Event Timer  
Select Enabled to activate the High Precision Event Timer (HPET) that produces  
periodic interrupts at a much higher frequency than a Real-time Clock (RTC) does  
in synchronizing multimedia streams, providing smooth playback, reducing the de-  
pendency on other timestamp calculation devices, such as an x86 RDTSC Instruc-  
tion embedded in the CPU. The High Performance Event Timer is used to replace  
the 8254 Programmable Interval Timer. The options are Enabled and Disabled.  
Trusted Computing (Available when a TPM device is detected  
by the BIOS)  
Configuration  
TPM Support  
Select Enabled on this item and enable the TPM jumper on the motherboard to  
enable TPM support to improve data integrity and network security. The options  
are Enabled and Disabled.  
TPM State  
Select Enabled to enable TPM security settings to improve data integrity and  
network security. The options are Disabled and Enabled.  
Pending Operation: This item displays the status of a pending operation.  
Current Status Information: This item displays the information regarding the  
current TPM status.  
TPM Enable Status  
This item displays the status of TPM Support to indicate if TPM is currently  
enabled or disabled.  
TPM Active Status  
This item displays the status of TPM Support to indicate if TPM is currently ac-  
tive or deactivated.  
TPM Owner Status  
This item displays the status of TPM Ownership.  
4-21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Intel TXT (LT-SX) Configuration  
Intel TXT (LT-SX) Hardware Support  
This feature indicates if the following hardware components support the Intel  
Trusted Execution Technology.  
CPU: TXT (Trusted Execution Technology) Feature  
Chipset: TXT (Trusted Execution Technology) Feature  
Intel TXT (LT-SX) Configuration  
This feature displays the following TXT configuration setting.  
TXT (LT-SX) Support: This item indicated if the Intel TXT support is enabled  
or disabled.  
Intel TXT (LT-SX) Dependencies  
This feature displays the features that need to be enabled for the Intel Trusted  
Execution Technology to work properly in the system.  
VT-d Support: Intel Virtualization Technology with Direct I/O support  
VT Support: Intel Virtualization Technology support  
TPM Support: Trusted Platform support  
TPM State: Trusted Platform state  
Intel ME Subsystem Configuration  
This feature displays the following ME Subsystem Configuration settings.  
ME BIOS Interface Version  
ME Version  
iSCSI Configuration: This item displays iSCSI configuration information:  
iSCSI Initiator Name: This item displays the name of the iSCSI Initiator, which  
is a unique name used worldwide.  
Intel® I350 Gigabit Network Connections: These items display the following  
information on the Intel I350 LAN connections.  
4-22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: AMI BIOS  
NIC Configuration  
Link Speed  
Use this feature to change the link speed and duplex for the current port. The op-  
tions are AutoNeg, 10Mbps Half, 10Mbps Full, 100Mbps Half, and 100Mbps full.  
Blink LEDs  
This feature allows the user to specify the duration for LEDs to blink. The range  
is from 0 ~ 15 seconds.  
PORT CONFIGURATION INFORMATION  
This section displays the following port information:  
UEFI Driver  
Adapter PBA  
Chip Type  
PCI Device ID  
PCI Bus:Device:Function  
Link Status  
Factory MAC Address  
Alternate MAC Address  
4-23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
4-4 Event Logs  
Use this feature to configure Event Log settings.  
Change SMBIOS Event Log Settings  
This feature allows the user to configure SMBIOS Event settings.  
Enabling/Disabling Options  
SMBIOS Event Log  
Select Enabled to enable SMBIOS (System Management BIOS) Event Logging  
during system boot. The options are Enabled and Disabled.  
Runtime Error Logging Support  
Select Enabled to support Runtime Error Logging. The options are Enabled and  
Disabled.  
Memory Correctable Error Threshold  
This feature allows the user to enter the threshold value for correctable memory  
errors. The default setting is 10.  
PCI Error Logging Support  
Select Enabled to support error event logging for PCI slots. The options are Enabled  
and Disabled.  
4-24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: AMI BIOS  
Erasing Settings  
Erase Event Log  
Select Enabled to erase the SMBIOS (System Management BIOS) Event Log, which  
is completed before a event logging is initialized upon system reboot. The options  
are No, Yes, Next reset, and Yes, Every reset.  
When Log is Full  
Select Erase Immediately to immediately erase SMBIOS error event logs that ex-  
ceed the limit when the SMBIOS event log is full. Select Do Nothing for the system  
to do nothing when the SMBIOS event log is full. The options are Do Nothing and  
Erase Immediately.  
SMBIOS Event Log Standard Settings  
Log System Boot Event  
Select Enabled to log system boot events. The options are Disabled and Enabled.  
MECI (Multiple Event Count Increment)  
Enter the increment value for the multiple event counter. Enter a number between  
1 to 255. The default setting is 1.  
METW (Multiple Event Count Time Window)  
This item allows the user to decide how long (in minutes) should the multiple event  
counter wait before generating a new event log. Enter a number between 0 to 99.  
The default setting is 60.  
View SMBIOS Event Log  
This item allows the user to view the event in the SMBIOS event log. Select this  
item and press <Enter> to view the status of an event in the log.  
4-25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
4-5 IPMI  
Use this feature to configure Intelligent Platform Management Interface (IPMI)  
settings.  
System Event Log  
Enabling/Disabling Options  
SEL Components  
Select Enabled for all system event logging at bootup. The options are Enabled  
and Disabled.  
Erasing Settings  
Erase SEL  
Select Yes, On next reset to erase all system event logs upon next system reboot.  
Select Yes, On every reset to erase all system event logs upon each system reboot.  
Select No to keep all system event logs after each system reboot. The options are  
No, Yes, On next reset, and Yes, On every reset.  
When SEL is Full  
This feature allows the user to decide what the BIOS should do when the system  
event log is full. Select Erase Immediately to erase all events in the log when the  
system event log is full. The options are Do Nothing and Erase Immediately.  
4-26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: AMI BIOS  
Customize EFI Logging Options  
Log EFI Status Codes  
Select Enabled to log EFI (Extensible Firmware Interface) Status Codes, Error  
Codes or Progress Codes. The options are Enabled and Disabled.  
Note: After making changes on a setting, be sure to reboot the system for  
the changes to take effect.  
BMC Network Configuration  
LAN Channel 1: This feature allows the user to configure the settings for LAN1 Port.  
Update IPMI LAN Configuration  
This feature allows the user to decide if the BIOS should configure the IPMI setting  
at next system boot. The options are No and Yes. If the option is set to Yes, the  
user is allow to configure the IPMI settings at next system boot:  
Configuration Address Source  
This feature allows the user to select the source of the IP address for this com-  
puter. If Static is selected, you will need to know the IP address of this computer  
and enter it to the system manually in the field. If DHCP is selected, the BIOS will  
search for a DHCP (Dynamic Host Configuration Protocol) server in the network  
that is attached to and request the next available IP address for this computer.  
The options are DHCP and Static. The following items are assigned IP addresses  
automatically if DHCP is selected.  
Station IP Address  
This item displays the Station IP address for this computer. This should be in decimal  
and in dotted quad form (i.e., 192.168.10.253).  
Subnet Mask  
This item displays the sub-network that this computer belongs to. The value of each  
three-digit number separated by dots should not exceed 255.  
Station Mac Address  
This item displays the Station Mac address for this computer. Mac addresses are  
6 two-digit hexadecimal numbers.  
Gateway IP Address  
This item displays the Gateway IP address for this computer. This should be in  
decimal and in dotted quad form (i.e., 192.168.10.253).  
4-27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
4-6 Boot  
This submenu allows the user to configure the following boot settings for the  
system.  
CSM Support  
Select Enabled to support the EFI Compatibility Support Module (CSM), which  
provides compatibility support for traditional legacy BIOS for system boot. The op-  
tions are Enabled, Disabled, and Auto.  
Boot Option #1/ Boot Option #2/ Boot Option #3  
Use this feature to specify the sequence of boot device priority.  
Network Devices  
This option sets the order of the legacy network devices.  
Delete Boot Options  
This item allows the user to select a boot device to delete from the boot priority list.  
4-28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: AMI BIOS  
4-7 Security  
This menu allows the user to configure the following security settings for the  
system.  
Administrator Password  
Use this feature to set the Administrator Password which is required to enter the  
BIOS setup utility. The length of the password should be from 3-characters to  
8-characters long.  
User Password  
Use this feature to set a User Password which is required to log into the system  
and to enter the BIOS setup utility. The length of the password should be from 3  
characters ~ 8 characters long.  
4-29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
4-8 Save & Exit  
This submenu allows the user to configure the Save and Exit settings for the  
system.  
Discard Changes and Exit  
Select this option to quit the BIOS Setup without making any permanent changes  
to the system configuration, and reboot the computer. Select Discard Changes and  
Exit, and press <Enter>. When the dialog box appears, asking you if you want to exit  
the BIOS setup without saving, click Yes to quit BIOS without saving the changes,  
or click No to quit the BIOS and save changes.  
Save Changes and Reset  
When you have completed the system configuration changes, select this option to  
save the changes and reboot the computer so that the new system configuration  
settings can take effect. Select Save Changes and Exit, and press <Enter>. When  
the dialog box appears, asking you if you want to exit the BIOS setup without sav-  
ing, click Yes to quit BIOS without saving the changes, or click No to quit the BIOS  
and save changes.  
Save Options  
Save Changes  
Select this option and press <Enter> to save all changes you've done so far and  
return to the AMI BIOS utility Program. When the dialog box appears, asking you if  
you want to save configuration, click Yes to save the changes, or click No to return  
to the BIOS without making changes.  
4-30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: AMI BIOS  
Discard Changes  
Select this feature and press <Enter> to discard all the changes and return to the  
BIOS setup. When the dialog box appears, asking you if you want to load previ-  
ous values, click Yes to load the values previous saved, or click No to keep the  
changes you've made so far.  
Restore Optimized Defaults  
Select this feature and press <Enter> to load the optimized default settings that  
help optimize system performance. When the dialog box appears, asking you if you  
want to load optimized defaults, click Yes to load the optimized default settings, or  
click No to abandon optimized defaults.  
Save as User Defaults  
Select this feature and press <Enter> to save the current settings as the user's  
defaults. When the dialog box appears, asking you if you want to save values as  
user's defaults, click Yes to save the current values as user's default settings, or  
click No to keep the defaults previously saved as the user's defaults.  
Restore User Defaults  
Select this feature and press <Enter> to load the user's defaults previously saved in  
the system. When the dialog box appears, asking you if you want to restore user's  
defaults, click Yes to restore the user's defaults previously saved in the system, or  
click No to abandon the user's defaults that were previously saved.  
Boot Override  
This feature allows the user to enter a new setting to overwrite the original setting  
that was saved for the following devices:  
IBA GE Slot  
UEFI: Built-in EFI Shell:  
4-31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Notes  
4-32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix A: BIOS POST Error Codes  
Appendix A  
BIOS Error Beep Codes  
During the POST (Power-On Self-Test) routines, which are performed at each  
system boot, errors may occur.  
Non-fatal errors are those which, in most cases, allow the system to continue to  
boot. The error messages normally appear on the screen.  
Fatal errors will not allow the system to continue with bootup procedure. If a  
fatal error occurs, you should consult with your system manufacturer for possible  
repairs.  
These fatal errors are usually communicated through a series of audible beeps.  
The numbers on the fatal error list correspond to the number of beeps for the  
corresponding error.  
A-1 BIOS Error Beep Codes  
X9 Motherboard BIOS Error Beep Codes  
Beep Code/LED  
Error Message  
Refresh  
Description  
Ready to boot  
1 beep  
5 short beeps + 1 long beep  
5 beeps  
Memory error  
No memory detected in the system  
No Con-In or No Con-  
Out devices  
Con-In includes USB or PS/2 key-  
board, PCI or Serial Console Redirec-  
tion, IPMI KVM or SOL.  
Con-Out includes Video Controller,  
PCI or Serial Console Redirection,  
IPMI SOL.  
1 beep per device  
1 Continuous Beep  
Refresh  
1 beep or each USB device detected  
X9 IPMI Error Codes  
System OH  
System Overheat  
A-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Notes  
A-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix B: Software Installation Instructions  
Appendix B  
Software Installation Instructions  
B-1 Installing Software Programs  
The Supermicro ftp site contains drivers and utilities for your system at ftp://ftp.  
supermicro.com. Some of these must be installed, such as the chipset driver.  
After accessing the ftp site, go into the CDR_Images directory and locate the ISO  
file for your motherboard. Download this file to create a CD/DVD of the drivers and  
utilities it contains. (You may also use a utility to extract the ISO file if preferred.)  
Another option is to go to the Supermicro Website at http://www.supermicro.com/  
products/. Find the product page for your motherboard here, where you may down-  
load individual drivers and utilities.  
After creating a CD/DVD with the ISO files, insert the disk into the CD/DVD drive  
on your system and the display shown below should appear.  
Driver/Tool Installation Display Screen  
Note 1: Click the icons showing a hand writing on paper to view the  
readme files for each item. Click the computer icons to the right of these  
items to install each item (from top to the bottom) one at a time. After  
installing each item, you must re-boot the system before moving on  
to the next item on the list. The bottom icon with a CD on it allows you  
to view the entire contents.  
Note 2: When making a storage driver diskette by booting into a Driver  
CD, please set the SATAConfiguration to "Compatible Mode" and configure  
SATA as IDE in the BIOS Setup. After making the driver diskette, be sure  
to change the SATA settings back to your original settings.  
B-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Note 3: Changing BMC log-in information is recommended during initial  
system power-on. The default username is ADMIN and password is  
ADMIN. For BMC best practices, please refer to http://www.supermicro.  
com/products/nfo/files/IPMI/Best_Practices_BMC_Security.pdf  
B-2 Configuring SuperDoctor III  
The SuperDoctor® III program is a web-based management tool that supports  
remote management capability. It includes Remote and Local Management tools.  
The local management is called SD III Client. The SuperDoctor III program allows  
you to monitor the environment and operations of your system. SuperDoctor III  
displays crucial system information such as CPU temperature, system voltages  
and fan status. See the figures below for examples of the SuperDoctor III interface.  
Note 1: The default User Name and Password for SuperDoctor III is  
ADMIN/ADMIN.  
Note 2: When SuperDoctor III is first installed, it adopts the temperature  
threshold settings that have been set in BIOS. Any subsequent changes to  
these thresholds must be made within SuperDoctor III, as the SuperDoc-  
tor III settings override the BIOS settings. To set the BIOS temperature  
threshold settings again, you would first need to uninstall SuperDoctor III.  
SuperDoctor® III Interface Display Screen (Health Information)  
B-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix B: Software Installation Instructions  
SuperDoctor® III Interface Display Screen (Remote Control)  
Note: The SuperDoctor III program and User’s Manual can be downloaded  
from the Supermicro web site at http://www.supermicro.com/products/ac-  
cessories/software/SuperDoctorIII.cfm. For Linux, we recommend that you  
use the SuperDoctor II application instead.  
B-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X9DRD-iF/LF Motherboard User’s Manual  
Notes  
B-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(Disclaimer Continued)  
The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices,  
aircraft/emergency communication devices or other critical systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic  
property damage. Accordingly, Supermicro disclaims any and all liability, and should buyer use or sell such products for use in such ultra-hazardous applications, it does so  
entirely at its own risk. Furthermore, buyer agrees to fully indemnify, defend and hold Supermicro harmless for and against any and all claims, demands, actions, litigation, and  
proceedings of any kind arising out of or related to such ultra-hazardous use or sale.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sharp Projector XG MB70X User Manual
Snapper Lawn Mower ZM5201M ZM5201M ZM6101M User Manual
Sony Car Stereo System CDX GT55IP User Manual
Sony Cordless Telephone SPP N1003 User Manual
Sony Digital Camera SNC DF50 User Manual
Sony Headphones MDRZX110 BLK User Manual
Sony Indoor Furnishings SU 27F2 User Manual
Southbend Saw sb1018 User Manual
System Sensor Smoke Alarm 2451TH User Manual
Targus Computer Drive 410 2217 001A User Manual