ADN-W AM
Antenna Module
Instruction manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
For your safety
Contents
For your safety ............................................................................................... 1
Package contents .......................................................................................... 2
Connecting the antenna module to the mains power supply .......... 6
Setting up and positioning the antenna module .................................... 7
Connecting the ADN-W AM antenna module to the ADN CU1
central unit ................................................................................................... 10
Switching the antenna module on/off ................................................... 11
Configuring the wireless components ..................................................... 12
Cleaning and maintaining the antenna module .................................... 13
Specifications ADN-W AM .......................................................................... 13
For your safety
Please make sure to read the “Safety information” supplement
included separately with the ADN CU1 central unit. This supplement
contains important information on the safe operation of the ADN
conference system as well as the manufacturer’s declaration and war-
ranty notes.
A detailed instruction manual for the overall ADN conference system
can be found
www
Manual
• on the DVD-ROM supplied with the ADN CU1 central unit.
The ADN-W AM antenna module
The ADN-W AM antenna module is part of the Sennheiser ADN confer-
ence system.
When connected to the ADN CU1 central unit, the ADN-W AM antenna
module controls the RF data transmission to and from the ADN-W D1
and ADN-W C1 wireless conference units.
ADN-W AM | 1
Download from Www.Somanuals.com. All Manuals Search And Download.
Package contents
Package contents
1 ADN-W AM antenna module with 3 rod antennas
(ADN-W AM or ADN-W AM-US version)
1 SDC CBL RJ45-5 system cable, length 5 m
1 thread insert (5/8" to 3/8")
1 instruction manual
Intended use
Intended use of the products includes
•
•
using the products for professional purposes,
having read and understood the safety instructions and the ADN
system manual,
•
using the products within the operating conditions and limitations
described in the ADN system manual.
“Improper use” means using the products other than as described in
the ADN system manual, or under operating conditions which differ
from those described therein.
All instruction manuals for components of the ADN conference system
www
Manual
2 | ADN-W AM
Download from Www.Somanuals.com. All Manuals Search And Download.
Components required for wireless operation
Components required for wireless operation
Central unit
Number Description
ADN CU1-EU central unit,
Cat. No. Function
1
505553 Controls the conference
(wired and wireless
EU version
components) and
ADN CU1-UK central unit,
UK version
505554
supplies power to the
ADN-W AM antenna
ADN CU1-US central unit,
US version
505555
module
Wireless
Number Description
Cat. No. Function
conference units
max. 150 ADN-W D1 wireless
delegate unit
504748 Allows to make contri-
butions to the
conference
1 - 10
ADN-W C1 wireless
504745 Allows to manage the
conference
(optional) chairperson unit
ADN-W BA battery pack
504744 Supplies power to wire-
less conference units
depending
on the
number of
wireless
confer-
ADN-W MIC 15-39
ADN-W MIC 36-29
ADN-W MIC 15-50
ADN-W MIC 36-50
504750
504751
504752
504753
Gooseneckmicrophones
to make contributions
ence units
Optional power supply
Number Description
Cat. No. Function
1
NT 12-50C-EU power supply, 505712 Supplies power to the
(optional) EU version
ADN-W AM antenna
module if the power
supply from the central
unit via the system
cable is not sufficient
NT 12-50C-UK power supply, 505713
UK version
NT 12-50C-US power supply, 505714
US version
Additional accessories for the ADN conference system can be
ADN-W AM | 3
Download from Www.Somanuals.com. All Manuals Search And Download.
Product overview ADN-W AM
Product overview ADN-W AM
6
7
6
7
6
7
1
2
95 mm
:
:
:
9
8
8
:
4
3
5
1
A
1
2
3
4
5
7
8
9
Hole for safety wire
Cable grip
Antenna coupling ring
Mounting holes for wall mounting
Output socket
Input socket
5/8" mounting thread
with 3/8" thread insert
>
A
Rubber feet
Type plate
Hollow jack socket for connection of
optional NT 12-50C power supply
6
Antennas
4 | ADN-W AM
Download from Www.Somanuals.com. All Manuals Search And Download.
Preparing the antenna module for operation
Preparing the antenna module for operation
Connecting the antennas
Always use all 3 antennas to ensure reliable wireless operation. The
3 antennas are connected upon delivery.
CAUTION
Radio communication outside the legal requirements!
When connecting antennas other than the supplied ones, the trans-
mission power of the conference system may not meet the legal
requirements and may cause interference to other radio equipment.
̈ Only connect the supplied rod antennas to the antenna module.
6
̈ Connect the 3 antennas
to the 3 antenna sockets.
7
̈ Screw down the 3 antenna coupling rings
as shown.
The antennas are connected and secured.
7
6
ADN-W AM | 5
Download from Www.Somanuals.com. All Manuals Search And Download.
Preparing the antenna module for operation
Connecting the antenna module to the mains power
supply
The antenna module is powered from the ADN CU1 central unit via the
SBC CBL RJ45 system cable.
If the power supplied via the system cable is not sufficient and
if the antenna module is not listed in the central unit‘s oper-
ating menu under “System Menu” > “Versions” > “Hardware
Version Info” or “Software Version Info”:
Software Version Info
Hardware Version Info
Main menu
CU1 SB:
ADN PS:
AM
1
1
1
System menu
Versions
No
̈ Use the optional NT 12-50C power supply.
CAUTION
Product damage due to an unsuitable power supply!
If you use an unsuitable power supply, this can cause damage to the
ADN-W AM antenna module.
̈ Only connect the NT 12-50C power supply to the antenna module.
2
̈ Connect the hollow jack plug
of the NT 12-50C power supply to
5
the hollow jack socket
.
EU
UK
US
5
3
2
NT 12-50C
2
̈ Pass the cable through the cable grip
as shown.
2
3
̈ Connect the Euro 8 connector of the mains cable to the socket of
the NT 12-50C power supply.
̈ Connect the mains plug of the mains cable to a wall socket.
6 | ADN-W AM
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting up and positioning the antenna module
Setting up and positioning the
antenna module
CAUTION
Danger of injury and material damage!
If improperly installed or insufficiently fixed, the
antenna module can fall from the wall, ceiling or stand or
tip over and can cause injury or material damage.
̈ Protect the antenna module against tipping or drop-
ping by means of a safety wire which is attached to
a separate hook.
̈ Always have the antenna module mounted by a qual-
ified specialist according to local, national and inter-
national regulations and standards.
The antenna module can be:
• mounted to a wall or ceiling by means of a ball joint (optional
accessory),
• mounted to a stand or
• placed on a flat surface (e.g. table)
Further information on mounting the antenna module can be
found in the ADN system manual.
ADN-W AM | 7
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting up and positioning the antenna module
CAUTION
Danger of intermodulation!
If you set up the antenna module and the wireless conference units too
close to one another, intermodulation can occur.
̈ Observe a minimum distance:
– of 1 m between the antenna module and the wireless conference
units and
– of 0.5 m between the wireless conference units.
ADN-W AM
ADN CU1
A
D
N
C
U
1
ESC
...
150
max. 50 m
> 1 m
> 0.5 m
> 0.5 m
> 0.5 m
Transmission range approx. 30 m
The transmission range of the antenna module and the wireless con-
ference units is approx. 30 m. The transmission range can vary
depending on location and environmental conditions such as wall
thickness, wall composition etc.
In some countries/regions (e.g. Canada), the use of wireless
components operating in the 5.15 to 5.25 GHz frequency band
(channel 5 to 8) is restricted to indoor use.
̈ Do not obstruct the antennas of the antenna module and the wire-
less conference units with any object.
̈ Set up the devices so that there is a “free line of sight” between the
wireless conference units and the antenna module.
̈ Place the antenna module as centrally as possible and above the
wireless conference units.
̈ Orient the 3 antennas of the antenna module so that they are par-
allel to each other and are directed at a 90° angle towards the wire-
less conference units.
90°
8 | ADN-W AM
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting up and positioning the antenna module
Ceiling mounting is recommended for rooms with a ceiling height of up
to approx. 10 m:
̈ Mount the antenna module to the center of the ceiling.
̈ Orient the antennas horizontally and at a 90° angle with respect to
the wireless conference units.
< 10 m
Wall mounting is recommended for rooms with a ceiling height of more
than 10 m because the wireless conference units have an omni-direc-
tional radiation pattern (approx. 30 m):
̈ Mount the antenna module to the wall at a height of max. 10 m
from the floor.
̈ Attach the antenna module upside down so that the antennas
point downwards.
̈ Slightly turn the antennas so that they are directed at a 90° angle
towards the wireless conference units.
> 10 m
To minimize restrictions in the transmission range:
̈ Avoid placing the antenna module outside the conference room,
behind support columns or boardings or next to other radio
equipment.
ADN-W AM | 9
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting the ADN-W AM antenna module to the ADN CU1 central unit
to the ADN CU1 central unit
̈ Use a system cable (supplied with the ADN-W AM; the maximum
8
cable length allowed is 50 m) to connect the PORT II socket
or
9
PORT I socket
of the ADN CU1 central unit to the input
4
socket
of the antenna module.
If the power supplied to the antenna module via the system
cable is not sufficient (the antenna module does not switch on),
you have to power the antenna module using the NT 12-50C
power supply (see page 6).
Optionally, you can also connect the antenna module to the
PORT sockets of an ADN PS power supply. It does not matter if
you are using a string or ring topology. The antenna module is
connected just like a conference unit to the cable string or cable
ring.
ADN CU1
ADN-W AM
IN –– AUDIO –– OUT
PORT II PORT
I
100-240V~
50/60Hz 240W
2x 52.8V
1.75A
3
4
8
9
PORT II PORT I
To optionally combine the antenna module with wired conference
units, connect the antenna module just like a wired conference unit:
3
̈ Use a system cable to connect the output socket
of the
antenna module to the IN socket of an ADN D1 or ADN C1 wired
conference unit.
Or:
̈ Use a system cable to connect the OUT socket of an ADN D1 or
4
ADN C1 wired conference unit to the input socket
antenna module.
of the
10 | ADN-W AM
Download from Www.Somanuals.com. All Manuals Search And Download.
Switching the antenna module on/off
ADN CU1
ADN PS
ADN PS
PORT I/PORT II
PORT I/PORT II
PORT I/PORT II
1 2
1 2
1
2
OUT
20
...
IN
IN
IN
20
20
...
...
OUT
OUT
Switching the antenna module on/off
The antenna module is connected to the ADN CU1 central unit and
automatically switches on when the central unit is switched on.
To switch the antenna module on:
1
̈ Set the on/off switch of the ADN CU1 central unit to position “I”.
The central unit switches on and its display panel lights up. The
connected ADN-W AM antenna module is also switched on.
ADN CU1
ADN-W AM
ADN CU1
ESC
ON
ON
1
To switch the antenna module off:
4
̈ Disconnect the system cable from the input socket
of the
antenna module.
Or:
1
̈ Set the on/off switch of the ADN CU1 central unit to position “0”.
The antenna module is switched off. The wireless conference units
try to reconnect to the antenna module and automatically switch
off after 5 minutes if no switched-on antenna module can be
found.
ADN-W AM | 11
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring the wireless components
Configuring the wireless components
CAUTION
Risk of violation of legal requirements!
If you are using radio frequencies and transmission powers that cannot
be used license-free in your country, there is a risk of violation of legal
requirements.
̈ Use only radio frequencies and transmission powers that are
approved and legal in your country.
̈ In the menu bar of the central unit‘s operating menu, click “Wireless
Menu” > “Country” and select the correct country/region in which
the conference system is to be used (see the ADN system manual).
For wireless conferencing, you have to configure the wireless compo-
nents in order to adapt the radio settings to the legal requirements of
your country and to the requirements of your conference.
For configuring the wireless components, you can either use the central
unit’s operating menu or the “Conference Manager” software.
However, the full functionality of a wireless conference system can
only be configured using the software in “Live” operating mode.
In some countries/regions (e.g. Canada), the use of wireless
components operating in the 5.15 to 5.25 GHz frequency band
(channel 5 to 8) is restricted to indoor use.
Adjusting the radio settings
1. Select the country/region in which the conference system is to be
used (“Wireless Menu” > “Country”).
The conference system only uses the radio settings that are
approved and legal in the selected country/region.
2. Select dynamic frequency management (“Wireless Menu” >
“Channel Selection” > “Automatic”).
All radio settings are made automatically. The conference system
automatically detects occupied frequencies and switches to an
unused frequency band in case of interference.
3. Select the access mode for the wireless conference units:
– Open access mode (“Wireless Menu” > “Access mode” >
“Open”)
All ADN-W D1 wireless conference units that are ready for
operation automatically connect to the antenna module and
can be used instantly. This access mode should be used if only
12 | ADN-W AM
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning and maintaining the antenna module
one wireless conference system is in use and if the default
eavesdropping protection is sufficient.
– Closed access mode (“Wireless Menu” > “Access Mode” >
“Closed”)
Only wireless conference units whose serial numbers are listed in
a participant list can be used in the wireless conference. If several
wireless conferences are held simultaneously, the closed access
mode ensures that the wireless conference units connect to the
correct conference system. This access mode increases the pro-
tection against eavesdropping because only selected and
enabled wireless conference units can be used.
Further information on how to configure the wireless confer-
ence components can be found in the ADN system manual.
Cleaning and maintaining the
antenna module
̈ Only use a dry and soft cloth to clean the product.
Specifications ADN-W AM
RF frequency range
RF output power
2.4 GHz; 5.1 to 5.9 GHz
25 to 100 mW (depending on the selected
country/region)
Power supply
12 to 15 V
alternatively via ADN PORT bus 52.8 V
Power consumption
Antennas
6 W
3 rod antennas with R-SMA connection
typ. 30 m
Transmission range
Mounting thread
Temperature range
5/8" and 3/8" thread insert
operation: +5°C to +45°C
storage: -25°C to +70°C
Relative humidity
operation: 20 to 95%
storage: 10 to 90%
Dimensions (W x H x D)
Weight
approx. 226 x 181 x 58 mm
approx. 1,660 g
ADN-W AM | 13
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications ADN-W AM
In compliance with
Europe
EMC
Radio
EN 301489-1/-17
EN 300328
0682
EN 301893
EN 300440-1/-2
EN 60065
Safety
Approved by
USA
47 CFR Part 15
FCC ID: DMOADNWAM
Canada
Japan
Industry Canada RSS 210
IC: 2099A-ADNWAM
Japanese Radio Law and Japanese Telecommu-
nications Business Law Compliance
202-SMA057
D 12-0044 202
This device is granted pursuant to the
Japanese Radio Law ( 電波法) and the Japanese
Telecommunications Business Law ( 電気通信事
業法 ). This device should not be modified(oth-
erwise the granted designation number will
become invalid)
CE Declaration of Conformity
RoHS Directive (2011/65/EU)
R&TTE Directive (1999/5/EC)
The declaration is available at
Before putting the product into operation,
please observe the respective country-specific
regulations.
Italy: For private use, a general authorization
for the frequency band 5150 - 5725 MHz is
required if our wireless system is used
outside own premises.
For public use, a general authorization is
required.
14 | ADN-W AM
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications ADN-W AM
Statements regarding the FCC and Industry Canada rules
This device complies with part 15 of the FCC rules and RSS-210 of Industry
Canada. Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any inter-
ference received, including interference that may cause undesired operation.
The device for operation in the band 5150-5250 MHz is only for indoor use to
reduce the potential for harmful interference to co-channel mobile satellite
systems.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instruc-
tions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installa-
tion. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the fol-
lowing measures:
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
•
Consult the dealer or an experienced radio/ TV technician for help.
Changes or modifications not expressly approved by Sennheiser electronic
Corp. could void the user’s authority to operate the equipment.
This Class B digital apparatus complies with the Canadian ICES-003.
ADN-W AM | 15
Download from Www.Somanuals.com. All Manuals Search And Download.
|