Sanyo Musical Instrument MPX MD4 User Guide

INSTRUCTION MANUAL  
MPX-CD4  
MPX-MD4  
MANUEL D’INSTRUCTIONS  
MANUAL DE INSTRUCCIONES  
English  
Français  
Español  
GB  
F
Multiplexer  
Multiplexeur  
Multiplexor  
E
About this manual  
Acerca de este manual  
Before installing and using this unit, please read this manual  
carefully. Be sure to keep it handy for later reference.  
Antes de instalar y usar este aparato, lea detenidamente  
este manual. Asegúrese de guardarlo a mano para futuras  
referencias.  
This manual gives basic connections and operating  
instructions for 2 models (Colour MPX-CD4, B/W MPX-MD4).  
Este manual le indica las conexiones básicas y las  
instrucciones de funcionamiento de dos modelos (Color  
MPX-CD4, Blanco y negro MPX-MD4).  
À propos de ce manuel  
Avant d’installer et d’utiliser cet appareil, veuillez lire ce  
manuel attentivement. Assurez-vous de le garder à portée  
de la main pour référence ultérieure.  
Ce manuel couvre les instructions de branchement et  
d’utilisation de base pour deux modèles (couleur MPX-CD4,  
noir et blanc MPX-MD4).  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTENTS  
PARTS NAMES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
FRONT PANEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3  
REAR PANEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4  
CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5  
FEATURES  
Duplexing function that allows 4 divisions split screen display  
even during live picture recording  
High speed single field switching  
Normal live picture display in 4 divisions split screen  
Video sensor and active recording functions for recording  
only when necessary  
Video loss warning function that can switch the display to  
colour bars or to a frozen image  
Timer function for recording live pictures only when required  
Computer control function using an RS232C connection  
Still image and zoom display modes in 4 divisions split  
screen and full screen display modes  
BASIC CONNECTIONS . . . . . . . . . . . . . . . . . . . . . .5  
CONNECTIONS TO THE S-VIDEO  
TERMINALS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5  
REMOTE CONTROLLER CIRCUIT  
CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6  
INSTALLING THE RACK MOUNTING  
BRACKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6  
BASIC OPERATIONS . . . . . . . . . . . . . . . . . . . . . . . 7  
MODE SWITCHING . . . . . . . . . . . . . . . . . . . . . . . . . .7  
SECURITY LOCK FUNCTION . . . . . . . . . . . . . . . . .8  
SETTINGS BACKUP FUNCTION . . . . . . . . . . . . . . .8  
RESET FUNCTION . . . . . . . . . . . . . . . . . . . . . . . . . .8  
LIVE PICTURE MODE . . . . . . . . . . . . . . . . . . . . . . 9  
4 DIVISIONS SPLIT SCREEN OPERATIONS . . . .10  
FULL SCREEN OPERATIONS . . . . . . . . . . . . . . . .12  
SEQUENTIAL DISPLAY OPERATIONS . . . . . . . .14  
MONITOR 2 OPERATIONS . . . . . . . . . . . . . . . . . .14  
VCR PLAYBACK MODE . . . . . . . . . . . . . . . . . . . . 15  
4 DIVISIONS SPLIT SCREEN OPERATIONS . . . .16  
FULL SCREEN OPERATIONS . . . . . . . . . . . . . . . .18  
SEQUENTIAL DISPLAY OPERATIONS . . . . . . . .20  
MENU SETTING MODE . . . . . . . . . . . . . . . . . . . . 21  
2 monitor outputs and S-VHS input/output terminals  
Up to 100 alarm recordings log on-screen display  
ACCESSORIES  
Power cord x1  
Fixer  
Power cord tie x1  
Rack mounting brackets  
bolts x4  
LANGUAGE SETTING . . . . . . . . . . . . . . . . . . . . . .22  
CLOCK AND DAYLIGHT SAVING SETTING . . . . .23  
CAMERA TITLE SETTING . . . . . . . . . . . . . . . . . . .24  
ALARM SETTING . . . . . . . . . . . . . . . . . . . . . . . . . .25  
SENSOR SETTING . . . . . . . . . . . . . . . . . . . . . . . . .26  
TIMER SETTING . . . . . . . . . . . . . . . . . . . . . . . . . . .28  
CLOCK, TITLE DISPLAY AND MONITOR  
SETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29  
VCR SIGNAL INPUT/OUTPUT AND  
COMPUTER CONTROL SETTING . . . . . . . . . . . . .31  
ALARM DATA DISPLAY . . . . . . . . . . . . . . . . . . . . .33  
ALARMS OPERATIONS . . . . . . . . . . . . . . . . . . . . 34  
EXTERNAL ALARMS . . . . . . . . . . . . . . . . . . . . . . .34  
VIDEO LOSS ALARM . . . . . . . . . . . . . . . . . . . . . . .34  
RS232C CONTROL . . . . . . . . . . . . . . . . . . . . . . . . 35  
CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35  
INTERFACE SPECIFICATIONS . . . . . . . . . . . . . . .35  
COMMANDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35  
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . 39  
2
English  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS NAMES  
FRONT PANEL  
1
2
3 4 5 6 7 8 9 F  
G
ALL RESET  
MON  
2
STILL  
EXIT  
ZOOM  
NEXT  
SEQUENCE  
QUAD  
LIVE  
VCR  
MENU  
1
2
3
4
POWER  
MENU RESET  
SHIFT  
H
This unit is not equipped with a power switch. The power is turned on/off when the supplied power cord is connected/disconnected at  
the power source.  
1 POWER indicator  
8 LIVE button and indicator  
Press this button to select the live input mode.  
2 Camera select buttons and camera indicators  
9 VCR button and indicator  
Use these buttons to select the picture from the  
corresponding camera. Also, when in 4 divisions split  
screen, 4 divisions zoom, still image or sequential display  
modes, press one of these buttons to return to the normal  
picture full screen display of the corresponding camera.  
Press this button to select the VCR playback input mode.  
F MENU button  
Press this button to display the menus. Press repeatedly to  
select the different menus in order. Buttons 3 to 9 are  
used for menu control (for more information, please refer to  
page 7).  
3 MON2 button and indicator  
Press this button to set the output at monitor 2.  
4 STILL button and indicator  
G ALL RESET button  
In 4 divisions split screen, 4 divisions zoom or full screen  
display modes, press this button to freeze the displayed  
image. Press the button one more time to cancel.  
H MENU RESET button (see page 8)  
5 ZOOM button and indicator  
In 4 divisions split screen or full screen display modes,  
press this button for a 2x zoomed in image. Press the  
button one more time to cancel.  
6 SEQUENCE button and indicator  
In 4 divisions split screen or full screen display modes,  
press this button for an automatic sequential full screen  
display of the pictures.  
7 QUAD button and indicator  
In full screen display or sequential display modes, press this  
button to switch to 4 division display mode. The default  
display mode is 4 division display mode.  
English  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS NAMES  
REAR PANEL  
1
2
3 4  
5
6 78  
9
F
S-VHS  
CAMERA  
OUT IN  
MONITOR  
VCR  
IN OUT  
VCR  
CONTROL  
RS232C  
IN  
1
OUT  
IN  
2
3
OUT  
IN  
4
OUT  
1
2
IN  
OUT  
G C R1 R2  
C
S
C
A
C
1
2
3
4
C
MONITOR 1  
G
H
I
(RS232C terminal)  
1 IN/OUT (Camera input/output) terminals  
Connect the cameras cable to the IN terminals.  
1 2 3 4 5  
You can use the OUT terminal to output the camera signal  
input at the IN terminal.  
2 MONITOR 1 (Monitor 1 output) terminal  
6 7 8 9  
Function  
3 MONITOR 2 (Monitor 2 output) terminal  
Pin No. Signal  
Signal direction  
1
2
3
4
5
6
7
8
9
4 VCR IN (Video cassette recorder input) terminal  
5 VCR OUT (Video cassette recorder output) terminal  
6 S-VHS VCR IN (VCR S-VIDEO signal input) terminal  
7 S-VHS VCR OUT (VCR S-VIDEO signal output) terminal  
8 MONITOR 1 (Monitor 1 S-VIDEO signal output) terminal  
9 RS232C (RS-232C) terminal  
RXD Data reception  
Computer Multiplexer  
TXD Data transmission Multiplexer Computer  
GND Ground  
RTS Request to send  
Multiplexer Computer  
To control this unit using a personal computer, connect the  
computer serial terminal to this terminal using a 9-pin  
D-SUB cable (sold separately).  
(CONTROL terminal)  
Pin  
F CONTROL terminal  
G Battery compartment  
H Power cord holder  
Signal  
G
C
R1  
R2  
C
S
Ground  
Common  
Remote input 1  
Remote input 2  
Common  
Using the supplied tie, attach the power cord to the holder  
as illustrated.  
Switching input (DC 5V)  
Ground  
C
A
C
1
Alarm output (DC 5V)  
Common  
Alarm input 1  
Alarm input 2  
Alarm input 3  
Alarm input 4  
Common  
2
3
I AC Power socket  
4
Insert the power cord female plug firmly into this socket.  
When the other plug of the power cord is connect to a live  
power source, the POWER indicator on the front panel will  
light.  
C
NOTE: Model MPX-MD4 does not have S-VIDEO IN, OUT  
terminals.  
4
English  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONNECTION  
Before making any connection, make sure all the devices are turned off.  
Before making the connections, please refer to the instruction manual accompanying each device. If the devices are not connected  
properly, that may cause a fire and/or damages.  
BASIC CONNECTIONS  
External alarm sensors  
(door bell, interphone, etc.)  
Monitors (sold separately)  
Timelapse VCR (sold separately)  
Alarm input  
terminal  
1
3
2
4
COM  
COM  
Video output  
terminal  
Video input  
terminal  
Switching output  
terminal  
Video input  
terminal  
Video input  
terminal  
COM  
S-VHS  
VCR  
CAMERA  
MONITOR  
VCR  
IN OUT  
CONTROL  
IN  
1
OUT  
IN  
2
OUT  
IN  
3
OUT  
IN  
4
OUT  
1
2
IN  
OUT  
G C R1 R2  
C
S
C
A
C
1
2
3
4
C
MONITOR 1  
Computer  
Signal flow  
VIDEO IN  
VIDEO OUT  
CAMERA IN  
(See page 35)  
CONNECTIONS TO THE S-VIDEO TERMINALS  
If connections are made to the S-VHS terminals, they will have the priority.  
Monitor 1 (sold separately)  
1
3
2
4
S-VIDEO input  
terminal  
S-VHS  
VCR  
MONITOR  
VCR  
IN OUT  
CONTROL  
RS232C  
1
2
IN  
OUT  
G
C
R1 R2  
C
S
C
A
C
1
2
3
4
C
MONITOR 1  
Timelapse VCR (sold separately)  
S-VIDEO output terminal  
S-VIDEO input terminal  
English  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONNECTION  
REMOTE CONTROLLER CIRCUIT CONNECTIONS  
Use the layout below to make a remote controller and make the connections to the remote input pins (R1, R2) of the  
CONTROL terminal as indicated. This will permit remote controlled operation of this unit.  
220  
SW 1: Camera 1  
220Ω  
SW 2: Camera 2  
300Ω  
SW 3: Camera 3  
360Ω  
220Ω  
SW 5 : Menu selection  
220Ω  
SW 6 : VCR playback  
300Ω  
SW 7 : Live picture  
360Ω  
SW 8 : 4 divisions split  
screen  
SW 9 : Monitor 2  
680Ω  
SW 10 : Camera sequential  
display  
SW 11 : Zoom  
1.2kΩ  
SW 12 : Still image  
CONTROL  
RS232C  
G C R1 R2  
C
S
C
A
C
1
2
3
4
C
SW 4: Camera 4  
470Ω  
820Ω  
SW: switch  
INSTALLING THE RACK MOUNTING BRACKETS (SOLD SEPARATELY)  
To mount this unit onto a rack, please use the rack mount hardware (model VA-RACMK 1) sold separately.  
1
Insert the head of two of the supplied bolts into the  
keyhole opening on the side of the unit.  
Insert the head of the bolt in the larger side, then slide it to  
the smaller side of the opening.  
1
2
2
Align the slot on the mounting bracket with the two  
bolts.  
Make sure the bolts have not moved from their position,  
then place a flat washer, a locking washer, and fix with a  
nut.  
NOTE:  
Make sure to use the bolts provided with this unit, as the  
bolts provided with the rack mount hardware are too short.  
3
Install the second mounting bracket on the opposite  
side, then attach the unit onto the rack using the rack  
mount bolts.  
3
6
English  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BASIC OPERATIONS  
MODE SWITCHING  
When the unit is connected to a power source, the default display mode will be as follows: live picture from the four cameras  
will be displayed in a 4 divisions split screen on monitor 1, and sequentially, full screen on monitor 2. You can use the VCR,  
LIVE and MENU buttons to switch to the desired mode (see below for further information).  
LIVE picture mode  
VCR playback mode  
LIVE picture mode  
Menu mode  
(LANGUAGE/LANG./IDIO.)  
ENGLISH  
FRANCAIS  
ESPANOL  
When the power on  
VCR  
LIVE  
MENU  
Live Picture Mode  
Menu Mode  
When the LIVE button is pressed, the live (direct) picture from  
the cameras connected to the camera input terminals (1 4) on  
the unit rear panel, will be displayed. While in live picture mode  
you can use the still and zoom functions (see page 9).  
Press the MENU button to display the menu. The buttons used  
for menu control (see page 21) are indicated below.  
Menu control buttons  
NOTE:  
ALL RESET  
MON 2  
STILL  
ZOOM  
SEQUENCE  
QUAD  
LIVE  
VCR  
MENU  
The unit will automatically start in the live picture or VCR  
MENU RESET  
SHIFT  
EXIT  
NEXT  
playback display mode (4 divisions split screen, full screen or  
sequential display) last selected. Therefore, when a mode is  
selected, the display mode will remain the same.  
5
4
3
2
1
If a camera is not connected at one of the input terminals,  
NO VIDEOwill be displayed on the monitor screen.  
1 c, l (VCR, LIVE) button  
Use these buttons to move the cursor to the right or down.  
c button: will move the cursor towards the right.  
l button: will move the cursor down.  
NO VIDEO  
2 +, (QUAD, SEQUENCE) buttons  
Use these buttons to select numbers, letters, symbols.  
VCR Playback Mode  
+ button: for forward selection  
button: for backward selection  
Start playback on the VCR. If the video signal is correctly  
recorded, the VCR playback image will be displayed on monitor  
1 when the VCR button is pressed. While in VCR playback  
mode you can use the still and zoom functions (see page 15).  
3 NEXT (ZOOM) button  
To select a sub-menu in order to set the title position, etc. Press  
the NEXT button to switch between the menu and the sub-menu.  
NOTE: If playing back a tape not recorded through this unit,  
4 EXIT (STILL) button  
NO IDwill be displayed on the monitor screen.  
To exit the menu mode.  
5 SHIFT (MON2) button  
Use this button and the c or l buttons to move the cursor to  
the left or up.  
NO ID  
Press and hold the SHIFT button, then press the c  
button to move the cursor to the left.  
Press and hold the SHIFT button, then press the l  
button to move the cursor up.  
English  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
BASIC OPERATIONS  
SECURITY LOCK FUNCTION  
RESET FUNCTION  
This function lets you lock the camera live picture mode or VCR  
playback mode, so that it cannot be switched to another mode.  
The menus can be reset or cleared.  
Camera Live Picture Mode Lock  
ALL RESET  
LIVE  
VCR  
MENU  
Press the LIVE button for about 3 seconds.  
MENU RESET  
A buzzer will be heard, and the VCR and MENU buttons will not  
operate if pressed. If the buttons are pressed, a buzzer will be  
heard.  
LIVE  
Using the MENU RESET Button  
VCR  
MENU  
A: While a menu is displayed, press the MENU RESET button  
to reset all the values of the displayed menu to the default  
values.  
B: If no menu is displayed, press the MENU RESET button to  
VCR Playback Mode Lock  
reset the time to the nearest hour.  
For example, between 10:30:00 and 11:29:59 the clock  
will be reset to 11:00:00.  
Press the VCR button for about 3 seconds.  
A buzzer will be heard, and the LIVE and MENU buttons will not  
operate if pressed. If the buttons are pressed, a buzzer will be  
heard.  
Using the ALL RESET button  
Press this button to reset the following:  
Reset the time and date in the (CLOCK SET) menu to the  
default setting.  
VCR  
LIVE  
MENU  
The display mode on monitor 1 will return to 4 divisions split  
screen (default mode).  
The display mode on monitor 2 will return to sequential, full  
screen (default mode).  
Canceling the Security Lock  
To cancel the security lock, press the same (LIVE or VCR)  
button again for about 3 seconds. A buzzer will be heard and the  
mode will be unlocked.  
NOTE:  
If the multiplexer does not function properly, press  
the ALL RESET button.  
Please note that all the settings mentioned above  
will be reset.  
SETTINGS BACKUP FUNCTION  
This unit is equipped with a backup battery (lithium battery) to  
maintain the clock settings. When the unit is used under normal  
conditions, the backup battery is recharged. The battery is fully  
recharged after a minimum of about 30 hours, and will maintain  
the clock settings for up to 30 days.  
NOTE: The settings may not be maintained properly if the  
backup battery has been recharged for less than 30  
hours when the power goes off.  
Battery Life  
If the power is turned off for about one hour or more, when the  
power is restored, the (CLOCK SET) menu is displayed so the  
clock settings can be checked.  
If the clock settings are reset to: 01-01-2000 SAT 00:00:00, that  
may indicate that the battery is dead and must be replaced.  
Replacing the Battery  
To replace the battery, please consult your dealer. After the  
battery has been replaced, press the ALL RESET button, then  
in the (CLOCK SET) menu set the date and time (see page 23).  
8
English  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LIVE PICTURE MODE  
Press the LIVE button.  
LIVE  
The live pictures from the cameras connected to the CAMERA IN terminals on the unit back  
panel will be displayed on monitor 1.  
Refer to the diagrams below for the buttons to press in order to select the desired operation  
mode.  
If recording, the signal at the VCR OUT terminal will switch according to the selected  
operation mode.  
Please refer to (VCR SET) on page 31, for more information on settings for recording.  
MONITOR 1 DISPLAYS AND FUNCTIONS  
(Still image)  
STILL  
4
(P10)  
Monitor 1  
(4 divisions split screen)  
(Zoomed in image)  
(Zoom range setting)  
STILL  
ZOOM  
ZOOM  
4
4
4
LIVE  
(P10)  
(Zoom) (P11)  
(Zoomed in still image)  
(Full screen)  
(Still image)  
STILL  
1
QUAD  
0 1  
s
(P12)  
(P12)  
(Zoomed in image)  
(Zoomed in still image)  
ZOOM  
STILL  
sz  
z
(P11, 12)  
(Automatic sequential display)  
SEQUENCE  
(P14)  
MONITOR 2 DISPLAYS AND FUNCTIONS  
Monitor 2  
(Automatic sequential display)  
(Automatic sequential display)  
(Full screen)  
MON 2  
SEQUENCE  
3
English  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 DIVISIONS SPLIT SCREEN OPERATIONS  
(Live picture on monitor 1)  
Press the QUAD button.  
QUAD  
The 4 divisions split screen display mode will be selected.  
Example 1: To freeze the image from camera 4  
1
2
Press the STILL button.  
The STILL indicator flashes and the still image display mode is selected.  
Press the camera select 4 button.  
The camera 4 indicator flashes, the image from camera 4 is frozen, and S”  
flashes on-screen.  
STILL  
4
To cancel the still image display mode  
Press the camera select 4 button one more time, then press the STILL button.  
The camera 4 indicator lights and the STILL indicator go off.  
Example 2: To zoom in the image from camera 4  
1
2
Press the ZOOM button.  
The ZOOM indicator flashes and the zoomed in image display mode is selected.  
Press the camera select 4 button.  
The camera 4 indicator flashes, the image from camera 4 is zoomed in, and Z”  
flashes on-screen.  
ZOOM  
4
To cancel the zoomed in image display mode  
Press the camera select 4 button one more time, then press the ZOOM button.  
The camera 4 indicator lights and the ZOOM indicator goes off.  
10  
English  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 DIVISIONS SPLIT SCREEN OPERATIONS  
(Live picture on monitor 1)  
Example 3: To zoom in the image from camera 4 and set  
the zoom range  
You can select the portion of the image to zoom in. The default zoomed in area is the  
centre of the image, but if a different zoom range is selected it will be memorized until  
changed or cancelled.  
1
2
1
2
Press the ZOOM button.  
The ZOOM indicator flashes and the zoomed in image display mode is selected.  
ZOOM  
4
Press the camera select 4 button for about 3 seconds.  
In full screen mode, Z(flashes) and the zoom range frame are displayed.  
NOTE: If during the zoom range setting, the frame displayed in full screen  
display mode is not moved for about 10 seconds, the display mode will  
automatically return to 4 divisions split screen display mode.  
To return to the setting mode, press the camera select 4 button again, for  
about 3 seconds.  
3
LIVE  
VCR  
SHIFT  
Z
c button:  
will move the frame to the right  
3
4
Press the c (or l) button to move the zoom range frame to the desired  
area of the image.  
SHIFT button + c button:  
will move the frame to the left  
l button:  
will move the frame down  
SHIFT button + l button:  
will move the frame up  
Press the camera select 4 button.  
The area selected by the zoom range frame is now zoomed in.  
If necessary, follow the same procedure to set the zoom range for the other  
cameras.  
4
NOTE: You can switch from zoomed in mode to normal (no zoom) mode by  
pressing the camera select 4 button repeatedly.  
To cancel the zoomed in image display mode.  
Press the ZOOM button.  
4
Example 4: To freeze the zoomed in image from camera 4  
1
2
Press the ZOOM button.  
The ZOOM indicator flashes and the zoomed in image display mode is selected.  
Press the camera select 4 button.  
The camera 4 indicator flashes, the image from camera 4 is zoomed in, and Z”  
flashes on-screen.  
ZOOM  
4
3
4
Press the STILL button.  
The STILL indicator flashes and the ZOOM indicator lights.  
Press the camera select 4 button.  
The camera 4 indicator flashes, the zoomed in image from camera 4 is frozen,  
and SZflashes on-screen.  
NOTE: A still image cannot be zoomed in.  
STILL  
4
To cancel the still and zoomed in image display mode.  
Press the camera select 4 button, then press the STILL button.  
Press the camera select 4 button, then press the ZOOM button.  
To cancel all the still image displays and zoomed in image displays.  
Multiple still image displays and the zoomed in displays can be set from the 4  
divisions split screen, to cancel all at once, press the STILL button, then press  
the ZOOM button.  
English  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FULL SCREEN OPERATIONS  
(Live picture on monitor 1)  
1
2
3
4
Press a camera select (1 4) button.  
The live pictures from the selected camera will be displayed full screen.  
Example 5: To freeze the image from camera 2  
1
2
Press the camera select 2 button.  
The camera 2 indicator lights, the image from camera 2 is displayed.  
Press the STILL button.  
The STILL indicator flashes, the image from camera 2 is frozen, and Sflashes  
0 2  
S
on-screen.  
STILL  
2
To cancel the still image display mode  
Press the STILL button. Sis erased and the normal display mode returns.  
Example 6: To zoom in the image from camera 3  
1
2
Press the camera select 3 button.  
The camera 3 indicator lights, the image from camera 3 is displayed.  
0 3  
Z
Press the ZOOM button.  
The ZOOM indicator flashes, the image from camera 3 is zoomed in, and Z”  
flashes on-screen.  
ZOOM  
3
NOTE: The zoomed in area will be as set by the zoom range frame (See  
example 7 on page 13).  
To cancel the zoomed in image display mode  
Press the ZOOM button. Zis erased and the normal display mode returns.  
12  
English  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FULL SCREEN OPERATIONS  
(Live picture on monitor 1)  
Example 7: To zoom in the image from camera 4 and set  
the zoom range  
You can select the portion of the image to zoom in. The default zoomed in area is the  
centre of the image, but if a different zoom range is selected it will be memorized until  
changed or cancelled.  
1
2
0 4  
Z
1
2
Press the camera select 4 button.  
The camera 4 indicator lights, the image from camera 4 is displayed.  
ZOOM  
4
Press the ZOOM button.  
The ZOOM indicator flashes, the image from camera 4 is zoomed in, and Z”  
flashes on-screen.  
3
4
Z
3
Press the camera select 4 button for about 3 seconds.  
The zoomed in image will switch to the normal display mode, and the zoom  
range frame is displayed.  
NOTE: If the zoom range frame is not moved for about 10 seconds, the display  
will automatically return to the normal zoomed in mode.  
To display the zoom range frame again, press the camera select 4 button  
for about 3 seconds.  
4
LIVE  
VCR  
Z
SHIFT  
4
5
Press the c (or l) button to move the zoom range frame to the desired  
area of the image.  
c button:  
will move the frame to the right  
SHIFT button + c button:  
will move the frame to the left  
Press the camera select 4 button.  
The area selected by the zoom range frame is now zoomed in.  
If necessary, follow the same procedure to set the zoom range for the other  
cameras.  
l button:  
will move the frame down  
SHIFT button + l button:  
will move the frame up  
To cancel the zoomed in image display mode.  
Press the ZOOM button. Zis erased and the normal display mode returns.  
5
While in zoom mode, if the camera select button is pressed one more time,  
depending on the movement of the subject, the image may be more or less  
clear. Pressing the camera select button repeatedly will produce the  
following according to the image conditions.  
Z
4
Image with little or no movement  
The image of a large subject will be clear, the picture quality of moving areas  
of the image will be coarse.  
Image with normal movement (people or vehicles)  
The moving objects in the image will be clear, the picture quality of areas of  
the image with little movement will be coarse.  
Example 8: To freeze the zoomed in image from camera 2  
1
2
3
Press the camera select 2 button.  
The camera 2 indicator lights, the image from camera 2 is displayed.  
Press the ZOOM button.  
The image from camera 2 is zoomed in, and Zflashes on-screen.  
Z 2  
Press the STILL button.  
The STILL indicator flashes and the ZOOM indicator lights. The zoomed in image  
ZOOM  
STILL  
2
is frozen, and SZflashes on-screen.  
To cancel the still and zoomed in image display mode.  
SZ 2  
Press the STILL button, then press the ZOOM button.  
English  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SEQUENTIAL DISPLAY OPERATIONS  
(Live picture on monitor 1)  
Sequential display of each camera pictures at 1 second  
interval  
Press the SEQUENCE button.  
The pictures from each camera are displayed sequentially at 1 second interval. The  
camera select indicators (1 4) light sequentially according to the displayed camera.  
NOTE:  
The sequential display speed (image interval) is set to 1 second in the (MONITOR  
SET) menu. To change the sequence speed setting, refer to MON1 SEQ. TIMER”  
on page 30.  
Only the channels where a camera is connected will be displayed. Empty channels  
will be skipped automatically.  
SEQUENCE  
Live picture will be displayed on monitor 2  
even during VCR playback mode.  
MONITOR 2 OPERATIONS  
MON 2  
Press the MON2 button.  
The monitor 2 mode is selected and the MON2 indicator lights. A camera live picture  
will be displayed sequentially or full screen on monitor 2.  
The monitor 2 display mode is memorized and the last one previously used will be  
automatically selected.  
A
Monitor 1  
Monitor 2  
A: SEQUENTIAL DISPLAY MODE OPERATIONS  
Press the camera select 2 button.  
The camera 2 indicator lights, the picture from camera 2 is displayed on monitor 2.  
B: FULL SCREEN DISPLAY MODE OPERATIONS  
Press the SEQUENCE button.  
The SEQUENCE indicator lights, sequential display mode is selected.  
MON2  
2
To cancel the monitor 2 operations  
Press the MON2 button.  
B
The previously selected display mode (full screen or sequential display) will  
be selected.  
Live pictures will be displayed in a 4 divisions split screen on monitor 1.  
TO DISPLAY ON MONITOR 2 THE SAME IMAGE AS ON  
MONITOR 1  
MON2  
SEQUENCE  
This function can be used to monitor the images from a second location.  
In the (MONITOR SET) menu, set the item MON2 MON1to Y(see page 30).  
NOTE: When this setting is used, the MON2 button will not operate.  
14  
English  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VCR PLAYBACK MODE  
Press the VCR button.  
VCR  
The VCR playback mode is selected. When a tape is played back, the recording of the live  
pictures will be displayed on monitor 1.  
During VCR playback mode, there will be no signal output at the VCR OUT terminal.  
MONITOR 1 DISPLAYS AND FUNCTIONS  
(Still image)  
STILL  
4
(P16)  
Monitor 1  
(4 divisions split screen)  
(Zoomed in image)  
(Zoom range setting)  
STILL  
ZOOM  
ZOOM  
4
4
4
LIVE  
(Zoomed in  
still image)  
(P16)  
(Zoom) (P17)  
(Full screen)  
(Still image)  
STILL  
1
QUAD  
0 1  
s
(P18)  
(P18)  
(Zoomed in image)  
(Zoomed in still image)  
ZOOM  
STILL  
sz  
z
(P17, 18)  
(Automatic sequential display)  
SEQUENCE  
(P20)  
MONITOR 2 DISPLAYS AND FUNCTIONS  
While the recorded pictures are displayed on monitor 1, a live picture will be displayed on monitor 2.  
Monitor 2: Live picture  
Monitor 1  
(Full screen)  
(Automatic sequential display)  
(Full screen)  
(Full screen)  
SEQUENCE  
MON 2  
VCR  
4
0 1  
0 1  
0 4  
(4 divisions split screen)  
English  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 DIVISIONS SPLIT SCREEN OPERATIONS  
(VCR playback on monitor 1)  
Press the QUAD button.  
QUAD  
The 4 divisions split screen display mode will be selected.  
Example 1: To freeze the recorded image from camera 4  
1
2
Press the STILL button.  
The STILL indicator flashes and the still image display mode is selected.  
Press the camera select 4 button.  
The camera 4 indicator flashes, the recorded image from camera 4 is frozen, and  
Sflashes on-screen.  
STILL  
4
To cancel the still image display mode  
Press the camera select 4 button one more time, then press the STILL button.  
The camera 4 indicator lights and the STILL indicator go off.  
Example 2: To zoom in the recorded image from camera 4  
1
2
Press the ZOOM button.  
The ZOOM indicator flashes and the zoomed in image display mode is selected.  
Press the camera select 4 button.  
The camera 4 indicator flashes, the recorded image from camera 4 is zoomed in,  
and Zflashes on-screen.  
ZOOM  
4
To cancel the zoomed in image display mode  
Press the camera select 4 button one more time, then press the ZOOM button.  
The camera 4 indicator lights and the ZOOM indicator goes off.  
16  
English  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 DIVISIONS SPLIT SCREEN OPERATIONS  
(VCR playback on monitor 1)  
Example 3: To zoom in the recorded image from camera 4  
and set the zoom range  
You can select the portion of the recorded image to zoom in. The default zoomed in  
area is the centre of the image, but if a different zoom range is selected it will be  
memorized until changed or cancelled.  
1
2
1
2
Press the ZOOM button.  
The ZOOM indicator flashes and the zoomed in image display mode is selected.  
ZOOM  
4
Press the camera select 4 button for about 3 seconds.  
In full screen mode, Z(flashes) and the zoom range frame are displayed.  
NOTE: If during the zoom range setting, the frame displayed in full screen  
display mode is not moved for about 10 seconds, the display mode will  
automatically return to 4 divisions split screen display mode.  
To return to the setting mode, press the camera select 4 button again, for  
about 3 seconds.  
3
LIVE  
VCR  
SHIFT  
Z
c button:  
will move the frame to the right  
3
4
Press the c (or l) button to move the zoom range frame to the desired  
area of the image.  
SHIFT button + c button:  
will move the frame to the left  
l button:  
will move the frame down  
SHIFT button + l button:  
will move the frame up  
Press the camera select 4 button.  
The area selected by the zoom range frame is now zoomed in.  
If necessary, follow the same procedure to set the zoom range for the other  
cameras.  
4
NOTE: You can switch from zoomed in mode to normal (no zoom) mode by  
pressing the camera select 4 button repeatedly.  
To cancel the zoomed in image display mode.  
Press the ZOOM button.  
4
Example 4: To freeze the zoomed recorded in image from  
camera 4  
1
2
Press the ZOOM button.  
The ZOOM indicator flashes and the zoomed in image display mode is selected.  
Press the camera select 4 button.  
The camera 4 indicator flashes, the recorded image from camera 4 is zoomed in,  
and Zflashes on-screen.  
ZOOM  
4
3
4
Press the STILL button.  
The STILL indicator flashes and the ZOOM indicator lights.  
Press the camera select 4 button.  
The camera 4 indicator flashes, the zoomed in recorded image from camera 4 is  
frozen, and SZflashes on-screen.  
NOTE: A still image cannot be zoomed in.  
STILL  
4
To cancel the still and zoomed in image display mode.  
Press the camera select 4 button, then press the STILL button.  
Press the camera select 4 button, then press the ZOOM button.  
To cancel all the still image displays and zoomed in image displays  
Multiple still image displays and the zoomed in displays can be set from the 4  
divisions split screen, to cancel all at once, press the STILL button, then press  
the ZOOM button.  
English  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FULL SCREEN OPERATIONS  
(VCR playback on monitor 1)  
1
2
3
4
Press a camera select (1 4) button.  
The recorded pictures from the selected camera will be displayed full screen.  
Example 5: To freeze the recorded image from camera 2  
1
2
Press the camera select 2 button.  
The camera 2 indicator lights, the recorded image from camera 2 is displayed.  
Press the STILL button.  
The STILL indicator flashes, the recorded image from camera 2 is frozen, and S”  
0 2  
S
flashes on-screen.  
STILL  
2
To cancel the still image display mode  
Press the STILL button. Sis erased and the normal display mode returns.  
Example 6: To zoom in the recorded image from camera 3  
1
2
Press the camera select 3 button.  
The camera 3 indicator lights, the recorded image from camera 3 is displayed.  
0 3  
Z
Press the ZOOM button.  
The ZOOM indicator flashes, the recorded image from camera 3 is zoomed in,  
and Zflashes on-screen.  
ZOOM  
3
NOTE: The zoomed in area will be as set by the zoom range frame. (See  
example 7 on page 19)  
To cancel the zoomed in image display mode  
Press the ZOOM button. Zis erased and the normal display mode returns.  
18  
English  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FULL SCREEN OPERATIONS  
(VCR playback on monitor 1)  
Example 7: To zoom in the recorded image from camera 4  
and set the zoom range  
You can select the portion of the recorded image to zoom in. The default zoomed in  
area is the centre of the image, but if a different zoom range is selected it will be  
memorized until changed or cancelled.  
1
2
0 4  
Z
1
2
Press the camera select 4 button.  
The camera 4 indicator lights, the recorded image from camera 4 is displayed.  
ZOOM  
4
Press the ZOOM button.  
The ZOOM indicator flashes, the recorded image from camera 4 is zoomed in,  
and Zflashes on-screen.  
3
4
Z
3
Press the camera select 4 button for about 3 seconds.  
The zoomed in image will switch to the normal display mode, and the zoom  
range frame is displayed.  
NOTE: If during the zoom range setting, the frame displayed is not moved for  
about 10 seconds, the display mode will automatically return to zoomed  
in display mode. To return to the setting mode, press the camera select 4  
button again, for about 3 seconds.  
4
LIVE  
VCR  
Z
SHIFT  
4
5
Press the c (or l) button to move the zoom range frame to the desired  
area of the image.  
c button:  
will move the frame to the right  
SHIFT button + c button:  
will move the frame to the left  
Press the camera select 4 button.  
The area selected by the zoom range frame is now zoomed in.  
If necessary, follow the same procedure to set the zoom range for the other  
cameras.  
l button:  
will move the frame down  
SHIFT button + l button:  
will move the frame up  
To cancel the zoomed in image display mode.  
Press the ZOOM button. Zis erased and the normal display mode returns.  
5
Z
4
Example 8: To freeze the zoomed in recorded image from  
camera 2  
1
2
3
Press the camera select 2 button.  
The camera 2 indicator lights, the recorded image from camera 2 is displayed.  
Z
Press the ZOOM button.  
The recorded image from camera 2 is zoomed in, and Zflashes on-screen.  
ZOOM  
STILL  
2
Press the STILL button.  
The STILL indicator flashes and the ZOOM indicator lights. The zoomed in image  
is frozen, and SZflashes on-screen.  
SZ  
To cancel the still and zoomed in image display mode.  
Press the STILL button, then press the ZOOM button.  
English  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SEQUENTIAL DISPLAY OPERATIONS  
(VCR playback on monitor 1)  
Sequential display of each camera pictures at 1 second  
interval  
Press the SEQUENCE button.  
The pictures from each camera are displayed sequentially at 1 second interval. The  
camera select indicators (1 4) light sequentially according to the displayed camera.  
NOTE:  
The sequential display speed (image interval) is set to 1 second in the (MONITOR  
SET) menu. To change the sequence speed setting, refer to MON1 SEQ. TIMER”  
on page 30.  
Only the channels where a camera image was recorded will be displayed. Empty  
channels will be skipped automatically.  
SEQUENCE  
20  
English  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MENU SETTING MODE  
MENUS DISPLAYS  
To display the menus, press the MENU button.  
Menu 1  
Menu 2  
MENU  
(CLOCK SET)  
(LANGUAGE/LANG./IDIO.)  
ENGLISH  
01-01-2000 SAT 00:00:00  
(DAYLIGHT SET)  
MODE  
NO USE  
WEEK MON TIME  
1ST-SUN 04 02:00  
STILL  
STILL  
FRANCAIS  
MENU  
MENU  
MENU  
MENU  
MENU  
MENU  
MENU  
MENU  
ON  
ESPANOL  
OFF LST-SUN 10 02:00  
EXIT  
EXIT  
Menu 3  
(TITLE SET)  
TITLE  
STILL  
1 ---------1  
2 ---------2  
3 ---------3  
4 ---------4  
EXIT  
Menu 4  
(ALARM SET)  
BUZZER  
ON  
DURATION  
RETRIGGER  
DATA  
10 S  
OFF  
ON  
STILL  
MON.1 OUT  
STILL  
FULL  
OFF  
OFF  
ZOOM  
EXIT  
DOUBLE ALARM SWITCH  
MENU  
MON.2 OUT  
OFF  
OFF  
ACTIVE REC  
Menu 5  
(Monitor 1)  
(SENSOR SET)  
ZOOM  
STILL  
ACTIVE REC  
DURATION  
MODE2  
05 S  
NEXT  
EXIT  
POSITION/LEVEL SET  
PRESS NEXT  
CAM1 OFF  
STILL  
Menu 6  
(TIMER SET)  
return  
EXIT  
DAY  
00:00  
NIGHT  
00:00  
TIME  
STILL  
CAMERA1 ON  
CAMERA2 ON  
CAMERA3 ON  
CAMERA4 ON  
ON  
ON  
ON  
ON  
EXIT  
Menu 7  
CAM1  
CAM3  
CAM2  
CAM4  
(DISPLAY SET)  
LIVE  
CLOCK  
TITLE  
OFF  
ON  
OFF  
ON  
VCR PB CLOCK  
TITLE  
POSITION SET†PRESS NEXT  
ZOOM  
STILL  
(MONITOR SET)  
NEXT  
MON1 SEQ.TIMER  
MON2 SEQ.TIMER  
01 S  
01 S  
N
01-01-2000  
00:00:00  
EXIT  
MON2  
MON1  
STILL  
EXIT  
Menu 8  
(VCR SET)  
VCR MODE  
TLS  
002 H  
return  
REC SPEED  
ALARM REC SPEED 002 H  
COLOR KILLER  
0FF  
STILL  
(VIDEO LOSS SET)  
VIDEO LOSS  
DATA  
ON  
ON  
DISPLAY  
FREEZE  
EXIT  
(RS232C SET)  
DATA SPEED  
19200  
Menu 9  
(ALARM DATA)  
1/13  
CAM DATE TIME ITEM  
1
2
3
4
5
6
7
8
-- ----- --:--  
-- ----- --:--  
-- ----- --:--  
-- ----- --:--  
-- ----- --:--  
-- ----- --:--  
-- ----- --:--  
-- ----- --:--  
-
-
-
-
-
-
-
-
STILL  
EXIT  
Normal picture display  
English  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LANGUAGE SETTING  
Menu 1  
(LANGUAGE/LANG./IDIO.)  
The default menu language is English. The available language  
settings are English, French and Spanish.  
Setting the language  
1
Press the MENU button 1 time to display the  
(LANGUAGE/LANG./IDIO.) menu.  
2
3
Press the l button to highlight the desired language.  
Press the MENU button to go to the next menu, or  
Press the EXIT button to exit the menu display and  
the selected language is set.  
All the on-screen menus and settings will be  
displayed in the selected language.  
(HORLOGE)  
01-01-2000 SAM 00:00:00  
(LANGUAGE/LANG./IDIO.)  
ENGLISH  
FRANCAIS  
ESPANOL  
(HEURE ETE)  
MODE  
NON  
SEM.  
MOIS HEURE  
MAR 1ER-DIM 04 02:00  
ARR DER-DIM 10 02:00  
MENU  
LIVE  
(AJUSTE DE RELOJ)  
01-01-2000 SAB 00:00:00  
(AJUSTE DE INTERVALO)  
MODO  
SIN USO  
SEMANA MES HORA  
PRI-DON 04 02:00  
ON  
OFF ULT-DON 10 02:00  
22  
English  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLOCK AND DAYLIGHT SAVING SETTING  
Menu 2  
TO MAKE CHANGES TO THE SETTINGS  
(CLOCK SET)  
1
2
Press the l button to highlight the NO USE setting,  
then press the + (or ) button to select USE, and  
press the l button one more time.  
The default setting is as indicated below. The clock will start  
after the actual time and date are set and the operations under  
(DAYLIGHT SET) are completed.  
Example: Setting the daylight saving time from the  
second Tuesday of May at 3:00 AM, to the  
fourth Tuesday of September at 3:00 AM.  
Default clock settings: 01:01:2000 SAT 00:00:00  
(January 1, 2000 at 00:00)  
1
2
Press the MENU button 2 times to display the (CLOCK  
SET) menu.  
1 Press the + (or ) button to set the WEEK (2ND), then  
press the c button.  
Menu: 1ST, 2ND, 3RD, 4TH or LST (first, second, third,  
Example: Setting the clock to October 15, 1999 at 3:20 PM  
1 Press the + (or ) button to set the month (10), then  
press the c button.  
2 Press the + (or ) button to set the day (15), then press  
fourth or last)  
2 Press the + (or ) button to set the WEEK (TUE), then  
press the c button.  
Menu: SUN, MON, TUE, WED, THU, FRI, SAT or SUN  
3 Press the + (or ) button to set the MON (05), then press  
the c button.  
Menu: 1, 2, 3, 4 ..... 11, 12  
(for January, February, March ..... December)  
4 Press the + (or ) button to set the TIME (03), then press  
the c button.  
3 Press the + (or ) button to set the year (1999), then  
press the c button.  
4 Press the + (or ) button to set the hours (15), then  
press the c button.  
5 Press the + (or ) button to set the minutes (20), then  
press the c button.  
NOTE: The day of the week (SAT) will be automatically set  
the c button.  
Following the same procedure as above, set when the  
time is changed back from daylight saving time to  
according to the date entered.  
standard time (the OFF settings).  
3
Press the l button to go to the (DAYLIGHT SET).  
Press the MENU button to go to the next menu  
screen, or  
3
Press the MENU button to go to the next menu  
screen, or  
Press the EXIT button to exit the menu display.  
Press the EXIT button to exit the menu display.  
2-1  
2-2~5  
(CLOCK SET)  
10-01-2000 SAT 00:00:00  
(CLOCK SET)  
10-15-1999 SAT 15:20:00  
1
2-1  
(DAYLIGHT SET)  
USE  
(DAYLIGHT SET)  
MODE  
MODE  
USE  
WEEK MON TIME  
1ST-SUN 04 02:00  
WEEK MON TIME  
2ND-SUN 04 02:00  
ON  
ON  
QUAD  
VCR  
LIVE  
QUAD  
OFF LST-SUN 10 02:00  
OFF LST-SUN 10 02:00  
QUAD  
LIVE  
QUAD  
VCR  
NOTE: To set the display mode for the title, refer to  
2-2  
2-3  
DISPLAY SET (CLOCK, TITLE)on page 29.  
(DAYLIGHT SET)  
(DAYLIGHT SET)  
USE  
MODE  
USE  
MODE  
WEEK MON TIME  
2ND-TUE 04 02:00  
WEEK MON TIME  
ON  
ON  
2ND-TUE 05 02:00  
OFF LST-SUN 10 02:00  
OFF LST-SUN 10 02:00  
QUAD  
VCR  
QUAD  
VCR  
(DAYLIGHT SET)  
2-4  
The default daylight saving time function setting is NO USE, so  
the daylight adjustment will not be made.  
If the unit will be used in an area where there is a daylight saving  
time change, set it to USE, then if necessary, set when the  
daylight saving time is changed.  
(DAYLIGHT SET)  
USE  
MODE  
WEEK MON TIME  
2ND-TUE 05 03:00  
ON  
OFF LST-SUN 10 02:00  
QUAD  
LIVE  
The default settings are:  
Daylight saving time from the first Sunday of April, at 2:00 AM  
(1ST-SUN 04 02:00) to last Sunday of October, at 2:00 AM  
(LST-SUN 10 02:00).  
English  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAMERA TITLE SETTING  
Menu 3  
When a picture from a camera is displayed on-screen the camera number (1 to 4) is displayed at the bottom of the image. You can  
enter a camera title, such as the camera location (up to 10 characters), that will be displayed instead of the camera number.  
(TITLE SET)  
1
2
Press the MENU button 3 times to display the (TITLE  
SET) menu.  
2-1  
2-2  
Example: To set the title GATE-1Ffor the camera 1  
and HALL-2Ffor camera 2.  
(TITLE SET)  
(TITLE SET)  
1 Press the + (or ) button to set the first character G,  
TITLE  
TITLE  
1 G  
2
1
2
3
4
1 GATE-1F 1  
--  
--------  
then press the c button.  
By pressing the + (or ) button repeatedly, the characters  
are selected as follows:  
2
3
4
2
3
4
---------  
---------  
---------  
---------  
---------  
---------  
3
4
Letters: A, B, C,....X, Y, Z  
Numbers: 0, 1,....8, 9  
Symbols: : . / * _  
QUAD  
VCR  
QUAD  
VCR  
2 Following the same procedure, enter the rest of the title  
ATE-1F.  
3 Press the l button to set the cursor at the first character  
2-3  
2-4  
location for camera 2.  
(TITLE SET)  
(TITLE SET)  
Press the + (or ) button to set first character H, then  
press the c button.  
4 Following the same procedure, enter the rest of the title  
TITLE  
TITLE  
1 GATE-1F 1  
--  
1 GATE-1F 1  
--  
2 H  
3
2
3
4
2 HALL-2F 2  
--  
---------  
---------  
--------  
---------  
---------  
3
4
3
4
4
ALL-2F.  
3
Press the MENU button to go to the next menu  
screen, or  
QUAD  
VCR  
QUAD  
LIVE  
VCR  
Press the EXIT button to exit the menu display.  
NOTE: To set the display mode for the title, refer to  
DISPLAY SET (CLOCK, TITLE)on page 29.  
24  
English  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ALARM SETTING  
Menu 4  
When an alarm trigger is received from sensors such as a door bell, movement sensor, etc. you can set the display mode and the  
recording mode for the pictures from the concerned camera.  
MON.1 OUT  
(ALARM SET)  
FULL: If an alarm trigger is received while in 4 divisions split  
screen, the picture from the camera corresponding to the  
alarm input will be displayed full screen. (Default setting)  
Changing the Settings  
If FULLis selected, refer to STILL, ZOOMand  
DOUBLE ALARMbelow for further settings.  
1
Press the MENU button 4 times to display the (ALARM  
SET) menu.  
QUAD:If an alarm trigger is received while in full screen, the  
display mode will switch to 4 divisions split screen.  
If QUADis selected, refer to STILLand ZOOM”  
below for further settings.  
2
3
Press the l button to highlight the setting to modify.  
Using the + (or ) button, select the desired setting,  
then press the l button.  
NC:  
The display mode will remain unchanged when an alarm  
trigger is received.  
Repeat step 3, until all the settings are as desired.  
4
Press the MENU button to go to the next menu  
screen, or  
Press the EXIT button to exit the menu display.  
STILL  
ON: The image from the camera corresponding to the alarm  
trigger will be frozen.  
OFF: The image will not be frozen. (Default setting)  
1, 2  
3
(ALARM SET)  
(ALARM SET)  
ZOOM  
BUZZER  
ON  
BUZZER  
ON  
DURATION  
RETRIGGER  
DATA  
10 S  
OFF  
ON  
FULL  
OFF  
OFF  
DURATION  
RETRIGGER  
DATA  
10 S  
OFF  
ON  
ON: The image from the camera corresponding to the alarm  
trigger will be zoomed in.  
OFF: The image will not be zoomed in. (Default setting)  
MON.1 OUT  
STILL  
MON.1 OUT  
STILL  
FULL  
OFF  
OFF  
ZOOM  
ZOOM  
DOUBLE ALARM SWITCH  
DOUBLE ALARM SWITCH  
MON.2 OUT  
OFF  
OFF  
MON.2 OUT  
OFF  
OFF  
ACTIVE REC  
ACTIVE REC  
DOUBLE ALARM  
QUAD  
LIVE  
LIVE  
This item is only displayed and can only be set if MON.1  
OUTabove is set to FULL.  
SWITCH: The picture from each concerned camera will be  
displayed sequentially at 1 second interval.  
(Default setting)  
FIRST: The picture from the first alarm received only is displayed.  
LAST: The picture from the last alarm received is displayed.  
ALARM SET menu  
BUZZER  
ON: A buzzer will be heard when an alarm trigger is received.  
(Default setting)  
OFF: The buzzer will not be heard.  
MON.2 OUT  
ON: Monitor 2 display will switch to full screen alarm display,  
when an alarm trigger is received.  
OFF: Monitor 2 display will not change. (Default setting)  
DURATION  
The alarm duration can be set to: 1, 2, 3, 4, 5, 10 (Default  
setting), 30 seconds, CC, NC  
ACTIVE REC  
CC: The alarm will go on for as long as the alarm signal is  
received (minimum 1 second).  
NC: The alarm will continue until canceled.  
ON: When an alarm trigger is received, the camera signals  
corresponding to the alarm trigger are recorded in priority.  
OFF: When an alarm trigger is received, the camera signals are  
recorded normally. (Default setting)  
RETRIGGER  
To set if an alarm is received while the unit is already in alarm  
mode.  
OFF: The unit will not receive another alarm, while one is  
NOTE: There are two ACTIVE REC alarm recording modes  
MODE1and MODE2that can be set in the  
(SENSOR SET) menu (see page 26).  
already being received. (Default setting)  
ON: During alarm mode, other alarm triggers will be received  
and the alarm duration will be extended.  
DATA  
The camera number, date, time, type of the alarm can be  
recorded. (To view the recorded alarm data, refer to ALARM  
DATA DISPLAYon page 33.)  
ON: The alarm data is recorded. (Default setting)  
OFF: The alarm data is not recorded.  
English  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SENSOR SETTING  
Menu 5  
You can set an area of the screen to be used as a sensor. You can also set the recording mode (ACTIVE REC) for sensor recording,  
when the sensor sends a trigger as it detects a movement.  
SETTING THE SENSOR POSITION AND  
SENSITIVITY LEVEL  
(SENSOR SET)  
Example: To adjust the camera 2 sensor position and  
Setting the ACTIVE REC Mode  
sensitivity level to 3  
1
Press the MENU button 5 times to display the (SENSOR  
SET) menu.  
1
From the (SENSOR SET) menu, press the NEXT button  
twice to go to the sub-menu for camera 2.  
2
3
Press the l button to highlight the setting to modify.  
The sub-menu for each camera is selected by pressing  
the NEXT button.  
The camera live picture is displayed, and the sensor  
position and sensitivity can be adjusted for that camera.  
Using the + (or ) button, select the desired setting,  
then press the l button.  
Repeat step 3, until all the settings are as desired.  
2
Using the l (or c) button move the sensor frame down  
(or right) to the desired sensor area position.  
4
Press the NEXT button to go to the POSITION/LEVEL  
SET sub-menu,  
Press and hold the SHIFT button, then press the l  
button to move the sensor frame up.  
Press the MENU button to go to the next menu  
screen, or  
Press and hold the SHIFT button, then press the c  
button to move the sensor frame to the left.  
Press the EXIT button to exit the menu display.  
Press and hold the SHIFT button, the press the + (or )  
button to adjust the bright of sensor frame.  
2
3
(SENSOR SET)  
(SENSOR SET)  
ACTIVE REC  
DURATION  
MODE2  
05 S  
ACTIVE REC  
DURATION  
MODE2  
05 S  
POSITION/LEVEL SET  
PRESS NEXT  
POSITION/LEVEL SET  
PRESS NEXT  
3
4
Press the + (or ) button to raise (or lower) the sensor  
sensitivity level (03).  
NOTE: The displayed frame will flash if there is movement  
within the sensor area during the setting.  
The available sensitivity levels are:  
OFF (not used), 1, 2,.....10 (10 being the most sensitive)  
LIVE  
QUAD  
LIVE  
SENSOR SET menu  
ACTIVE REC  
Press the EXIT button to return to the menu display,  
Press the MENU button to go to the next menu  
screen, or  
MODE1: The live pictures from the camera corresponding to the  
Press the EXIT button to exit the menu display.  
alarm trigger only are recorded.  
MODE2: The live pictures from the camera corresponding to the  
alarm trigger are recorded together with the pictures  
from the other cameras. (Default setting)  
Sensor frame  
1
(SENSOR SET)  
ACTIVE REC  
DURATION  
MODE2  
05 S  
NOTE:  
ZOOM  
POSITION/LEVEL SET  
PRESS NEXT  
For further details, please refer to the example on the  
next page.  
CAM2 OFF  
NEXT  
DURATION  
2
3
The recording duration can be set to:  
01, 02, 03, 04, 05 (Default setting), 10, 30 seconds  
LIVE  
QUAD  
MON2  
CAM2 OFF  
CAM2 03  
SHIFT  
Sensitivity Level  
26  
English  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SENSOR SETTING  
Menu 5  
ACTIVE REC Settings Examples  
Example 1: Recording on the tape when an alarm trigger is received from camera 2  
(ACTIVE REC: OFF)  
Alarm trigger in  
Alarm trigger in  
Alarm trigger out  
Alarm trigger out  
(ACTIVE REC: MODE1)  
(ACTIVE REC: MODE2)  
Alarm duration for camera 2  
Alarm duration for camera 2  
Normal recording  
(no alarm trigger)  
Example 2: Recording on the tape when an alarm trigger is received from camera 4 when an  
alarm trigger has already been received from camera 2  
(ACTIVE REC: OFF)  
Alarm trigger in  
Alarm trigger in  
Alarm trigger out  
Alarm trigger out  
(ACTIVE REC: MODE1)  
Alarm trigger received from camera  
4 during the alarm duration for  
trigger from camera 2  
Alarm duration for camera 2 is over,  
remaining alarm duration for trigger  
from camera 4  
Alarm duration for  
camera 2  
Alarm trigger in  
Alarm trigger out  
Alarm trigger out  
Alarm trigger in  
(ACTIVE REC: MODE2)  
Alarm trigger received from camera  
4 during the alarm duration for  
trigger from camera 2  
Alarm duration for camera 2 is over,  
remaining alarm duration for trigger  
from camera 4  
Normal recording  
(no alarm trigger)  
Alarm duration for  
camera 2  
English  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TIMER SETTING  
Menu 6  
You can set a DAY and a NIGHT range for the 24 hour day period, in order to set the VCR recording for each camera accordingly.  
2-1  
2-2  
(TIMER SET)  
(TIMER SET)  
(TIMER SET)  
DAY  
07:00  
NIGHT  
00:00  
DAY  
07:30  
NIGHT  
00:00  
TIME  
TIME  
1
2
Press the MENU button 6 times to display the (TIMER  
SET) menu.  
CAMERA1  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
CAMERA1  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
CAMERA2  
CAMERA2  
CAMERA3  
CAMERA4  
CAMERA3  
CAMERA4  
Example: Day period recording from 7:30 AM to 7:30 PM  
Night period recording from 7:30 PM to 7:30  
AM  
QUAD  
QUAD  
VCR  
1 Using the + (or ) button, select (7) for the starting hour  
of the DAY period, then press the c button.  
2 Using the + (or ) button, select (30) for the starting  
3-1  
3-2  
(TIMER SET)  
(TIMER SET)  
minutes of the DAY period, then press the c button.  
Using the same method, enter the settings for the  
starting hour/minutes of the NIGHT period.  
DAY  
07:30  
NIGHT  
19:30  
DAY  
07:30  
NIGHT  
19:30  
TIME  
TIME  
CAMERA1  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
CAMERA1  
ON  
ON  
ON  
ON  
OFF  
ON  
CAMERA2  
CAMERA2  
CAMERA3  
CAMERA4  
CAMERA3  
CAMERA4  
ON  
ON  
3
Example: Setting cameras 1 and 4 to be recorded  
during the day but not during the night, and  
cameras 2 and 3 to be recorded during the  
night but not during the day.  
QUAD  
VCR  
LIVE  
QUAD  
CAMERA 1: Set DAY to ON, NIGHT to OFF.  
CAMERA 2: Set DAY to OFF, NIGHT to ON.  
CAMERA 3: Set DAY to OFF, NIGHT to ON.  
CAMERA 4: Set DAY to ON, NIGHT to OFF.  
3-3  
(TIMER SET)  
DAY  
07:30  
NIGHT  
19:30  
TIME  
1 Press the l button to highlight the CAMERA 1 setting  
under DAY, then if necessary press the + (or ) button to  
select the desired setting (ON).  
CAMERA1  
ON  
OFF  
ON  
CAMERA2  
OFF  
ON  
CAMERA3  
CAMERA4  
ON  
ON  
ON  
2 Press the c button to highlight the setting under NIGHT,  
then if necessary press the + (or ) button to select the  
desired setting (OFF).  
LIVE  
QUAD  
VCR  
QUAD  
3 Press the l button to switch to the CAMERA 2 setting,  
and repeat the setting procedure above.  
Following the same procedure as above, select the  
CAMERA 3 and 4 settings.  
Sample setting  
(TIMER SET)  
DAY  
NIGHT  
19:30  
TIME  
07:30  
4
Press the MENU button to go to the next menu  
screen, or  
Press the EXIT button to exit the menu display.  
CAMERA1  
CAMERA2  
CAMERA3  
CAMERA4  
ON  
OFF  
ON  
OFF  
OFF  
ON  
ON  
OFF  
NOTE:  
2
4
3
1
2
3
The OFF and ON settings made in this menu will not affect  
the display of the camera signals on the monitor. They only  
set when these signals are recorded if a timelapse or real  
time VCR is connected to this unit for recording.  
1
4
When there is an external alarm trigger and sensor alarm  
trigger for a camera, the signals from that camera will be  
recorded even if the OFFsetting is selected in this menu.  
28  
English  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLOCK, TITLE DISPLAY AND MONITOR  
SETTINGS  
Menu 7  
SETTING THE CAMERA TITLE AND THE  
CLOCK DISPLAY POSITION (POSITION SET)  
(DISPLAY SET)  
The clock and the camera title settings entered in the menus  
(CLOCK SET) and (TITLE SET) can be displayed on-screen.  
1
2
3
From the (DISPLAY SET) menu, press the NEXT button.  
The 4 divisions split screen display mode is selected.  
Setting the Display Mode for the Clock and  
Camera Title  
Using the + (or ) button, set the camera title display  
position. (Select among the 4 positions.)  
1
2
Press the MENU button 7 times to display the (DISPLAY  
SET) menu.  
Using the l button, set the clock display position.  
NOTE: To move the display in the opposite direction, press  
and hold the SHIFT button, then press the l button.  
Using the + (or ) button, select the desired setting,  
then press the l button.  
4
Press the NEXT button to return to the (DISPLAY  
SET) menu.  
Following this procedure, select the settings for LIVE  
CLOCK, TITLE and VCR PB CLOCK, TITLE.  
Press the MENU button to go to the next menu  
screen, or  
3
4
Press the NEXT button to go to the POSITION SET  
sub-menu, then one more press NEXT button to return  
to the (DISPLAY SET) menu.  
Press the EXIT button to exit the menu display.  
(DISPLAY SET)  
1
LIVE  
CLOCK  
TITLE  
ON  
ON  
ON  
ON  
Press the l button to go to the next menu (MONITOR SET).  
VCR PB CLOCK  
TITLE  
POSITION SET†PRESS NEXT  
ZOOM  
Press the MENU button to go to the next menu  
screen, or  
NEXT  
(MONITOR SET)  
MON1 SEQ.TIMER  
MON2 SEQ.TIMER  
01 S  
01 S  
N
Press the EXIT button to exit the menu display.  
MON2  
MON1  
2
3
CAM1  
CAM3  
CAM2  
CAM4  
(DISPLAY SET)  
CLOCK  
CAM1  
CAM2  
CAM4  
LIVE  
OFF  
ON  
2
TITLE  
VCR PB CLOCK  
TITLE  
POSITION SET†PRESS NEXT  
OFF  
ON  
QUAD  
CAM1  
CAM3  
CAM2  
CAM4  
CAM3  
CAM1  
(MONITOR SET)  
MON1 SEQ.TIMER  
MON2 SEQ.TIMER  
01 S  
01 S  
N
MON2  
MON1  
QUAD  
LIVE  
CAM2  
CAM4  
CAM1  
CAM3  
CAM2  
CAM4  
DISPLAY SET menu  
LIVE CLOCK  
CAM3  
CAM1  
CAM2  
ON: The clock is displayed during live picture mode.  
OFF: The clock is not displayed during live picture mode.  
3
LIVE  
(Default setting)  
CAM3  
CAM4  
LIVE TITLE  
10-15-1999  
15:40:00  
ON: The camera title is displayed during live picture mode.  
(Default setting)  
OFF: The camera title is not displayed during live picture mode.  
VCR PB CLOCK  
ON: The clock is displayed during VCR playback picture mode.  
OFF: The clock is not displayed during VCR playback picture  
mode. (Default setting)  
VCR PB TITLE  
ON: The camera title is displayed during VCR playback picture  
mode. (Default setting)  
OFF: The camera title is not displayed during VCR playback  
picture mode.  
English  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLOCK, TITLE DISPLAY AND MONITOR SETTINGS  
Menu 7  
(MONITOR SET)  
You can set the display sequence speed on the monitors and  
have monitor 1 display the same image as monitor 2.  
Setting the Monitor Display  
1
2
Press the NEXT button to return to the (DISPLAY SET).  
Press the l button to highlight the setting to modify.  
Using the + (or ) button, select the desired setting,  
then press the l button.  
Following this procedure, select the settings or MON1,  
MON2 SEQ. TIMER and MO2 MON1.  
3
Press the MENU button to go to the next menu  
screen, or  
Press the EXIT button to exit the menu display.  
1
2
CAM1  
CAM3  
CAM2  
CAM4  
(DISPLAY SET)  
CLOCK  
LIVE  
ON  
ON  
ON  
ON  
TITLE  
VCR PB CLOCK  
TITLE  
POSITION SET†PRESS NEXT  
(MONITOR SET)  
MON1 SEQ.TIMER  
MON2 SEQ.TIMER  
MON2  
01 S  
01 S  
N
MON1  
ZOOM  
LIVE  
QUAD  
LIVE  
NEXT  
MONITOR SET menu  
MON1 SEQ. TIMER  
To set the display sequence speed (interval) on monitor 1.  
The available intervals are:  
01 (Default setting), 02, 03, 04, 05, 10, 20, 30 seconds  
MON2 SEQ. TIMER  
To set the display sequence speed (interval) on monitor 2.  
The available intervals are:  
01 (Default setting), 02, 03, 04, 05, 10, 20, 30 seconds  
MON2 MON1  
To have monitor 1 display the same image as monitor 2.  
N (No): Monitor 2 will only display camera live picture, in full  
screen or sequential display mode. (Default setting)  
Y(Yes): The display on monitor 2 will be the same as the one on  
monitor 1.  
30  
English  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VCR SIGNAL INPUT/OUTPUT AND  
COMPUTER CONTROL SETTING  
Menu 8  
Table 1  
(VCR SET)  
Recording speed setting on the  
real time VCR  
REC SPEED setting  
You must set this unit output to match the type (Timelapse or  
006 (6H)  
8H (8-hour mode)  
24H (24-hour mode)  
40H (40-hour mode)  
Real time VCR) and settings of the VCR used for recording.  
018 (18H)  
Setting the VCR Output  
030 (30H)  
1
2
Press the MENU button 8 times to display the (VCR  
SET) menu.  
ALARM REC SPEED  
With a timelapse VCR  
Set the recording speed to use when an alarm trigger is received to  
match the alarm recording speed of the timelapse VCR.  
The available speeds are:  
002 (2H) (Default setting), 012 (12H), 024 (24H), NC, F2  
Press the l button to highlight the setting to modify,  
then using the + (or ) button select the desired setting.  
Following this procedure, select the settings for VCR MODE,  
REC SPEED, ALARM REC SPEED and COLOR KILLER.  
NC: When an alarm trigger is received, the recording speed is  
3
Press the l button to go to the next menu (VIDEO  
LOSS SET), (RS232C SET),  
not changed and stays as set under REC SPEED.  
F2: Use this setting when using the SW output terminal on a  
timelapse VCR that does not output a switching signal in  
2H mode.  
With a real time VCR  
Set the recording speed to use when an alarm trigger is received to  
match the alarm recording speed of the real time VCR.  
The available speeds are:  
006 (6H) (Default setting), 018 (18H), NC, F6  
NC: When an alarm trigger is received, the recording speed is  
Press the MENU button to go to the next menu  
screen, or  
Press the EXIT button to exit the menu display.  
(Timelapse VCR)  
(Real time VCR)  
2
(VCR SET)  
(VCR SET)  
VCR MODE  
VCR MODE  
TLS  
REAL  
REC SPEED  
002 H  
REC SPEED  
006 H  
ALARM REC SPEED 002 H  
ALARM REC SPEED 006 H  
COLOR KILLER  
0FF  
COLOR KILLER  
0FF  
<VIDEO LOSS SET>  
<VIDEO LOSS SET>  
QUAD  
LIVE
not changed and stays as set under REC SPEED.  
F6: Use this setting when using the SW output terminal on a real  
time VCR that does not output a switching signal in 6H mode.  
VCR SET menu  
COLOR KILLER  
If the VCR is not Equipped with a SW (switching) Output  
Connector  
Used to playback a tape recorded through a black and white  
multiplexer, using a color multiplexer.  
VCR MODE  
ON: When using a black and white tape, the color killer  
function is active.  
OFF: The color killer function is not active. (Default setting)  
TLS: If using a timelapse VCR. (Default setting)  
REAL: If using a real time VCR.  
REC SPEED  
If the VCR is Equipped with a SW (switching) Output  
Connector (using the VCR switching signal)  
The recording speed settings on this unit correspond to  
recording durations on a T-120 tape.  
Make the connection from this unit to the VCR SW output  
connector. The video signal output by this unit will be  
automatically switched to the recording speed according to the  
switching signal output by the VCR (switching pulse setting on  
the VCR).  
The (VCR SET) menu REC SPEEDand ALARM REC  
SPEEDitems do not need to be set.  
With a timelapse VCR  
Set the recording speed to match the recording speed of the  
timelapse VCR.  
The available speeds are: 002 (2H) (Default setting), 012  
(12H), 024 (24H), 048 (48H), 072 (72H), 096 (96H), 120, 168,  
240, 360, 480, 720, 960 (960H)  
With a real time VCR  
Set the recording speed to match the recording speed of the real  
time VCR.  
The available speeds are: 006 (6H) (Default setting), 018  
(18H), 030 (30H), 048 (48H), 072 (72H), 096 (96H), 120, 168,  
240, 360 , 480, 720, 960 (960H)  
If a switching signal is not output at the switching terminal  
Some VCR models may not output a switching signal in 2H or  
6H mode. In such a case, make the settings as indicated in the  
table below.  
VCR SET menu settings  
REC SPEED  
ALARM REC SPEED  
Timelapse VCR Real time VCR  
002 (2H)  
002 (F2)  
006 (6H)  
006 (F6)  
NOTE: Real time VCRs speed is based on a T-160 cassette  
tape. When setting this unit to 6H, 18H or 30H, refer to  
the table 1 for the speed correspondence, and select  
the speed on the VCR accordingly.  
NOTE: When the alarm recording speed is set to F2 or F6, the  
recording speed is fixed to 2H or 6H. Therefore, when  
using a speed other than 2H or 6H, do not use the F2 or  
F6 setting.  
English  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VCR SIGNAL INPUT/OUTPUT AND COMPUTER CONTROL  
SETTING  
Menu 8  
(VIDEO LOSS SET)  
(RS232C SET)  
When the live picture signal feed is interrupted, you can set the  
action taken, and if the video loss is recorded as alarm data.  
First set VIDEO LOSSto ON, then make the DATAand  
DISPLAYsettings as desired.  
Connect the multiplexer to a computer, using a 9-pin D-SUB  
cable (sold separately), then set the maximum communication  
speed between the unit and the computer.  
For detailed information, refer to RS232C CONTROLon page 35.  
Setting the Video Loss Mode  
Changing the Setting  
1
2
Press the l button to highlight the setting to modify.  
1
2
Press the l button to highlight the setting to modify.  
Using the + (or ) button, select the desired setting,  
then press the l button.  
Using the + (or ) button, select the desired setting.  
The available speeds are:  
Following this procedure, select the settings for DATA and  
DISPLAY.  
2400, 4800, 9600, 19200 (Default setting) bps  
3
Press the MENU button to go to the next menu  
screen, or  
Press the EXIT button to exit the menu display.  
3
Press the l button to go to the next menu,  
Press the MENU button to go to the next menu  
screen, or  
1, 2  
Press the EXIT button to exit the menu display.  
(RS232C SET)  
DATA SPEED  
19200  
1, 2  
LIVE  
QUAD  
(VIDEO LOSS SET)  
VIDEO LOSS  
ON  
DATA  
ON  
DISPLAY  
FREEZE  
(RS232C SET)  
DATA SPEED  
19200  
LIVE  
QUAD  
VIDEO LOSS SET menu  
VIDEO LOSS  
You can set the action to take when there is an interruption in  
the video signal feed.  
ON: When there is video loss, the image just previous to the  
interruption is frozen on-screen or color bars are displayed  
(see DISPLAYbelow) and VIDEO LOSSis displayed  
on-screen. (Default setting)  
OFF: When there is video loss, NO VIDEOis displayed  
on-screen.  
DATA  
You can set the data (date, time, etc) of the video losses to be  
recorded as alarm data. (To view the recorded data, refer to  
ALARM DATA DISPLAYon page 33.)  
ON: The video losses data is recorded as alarm data. (Default  
setting)  
OFF: The video losses data is not recorded.  
DISPLAY  
You can set the display mode when there is an interruption in  
the video signal feed.  
FREEZE: When there is video loss, the image just previous to  
the interruption is frozen on-screen. (Default setting)  
TEST:  
When there is video loss, color bars are displayed  
on-screen.  
32  
English  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ALARM DATA DISPLAY  
Menu 9  
According to the settings entered in the (ALARM SET), (SENSOR SET) and (VIDEO LOSS SET) menus, information about the alarms  
(alarm data) can be recorded. Up to 100 alarm data entries can be displayed on-screen (separate 13).  
(ALARM DATA)  
Displaying the Alarm Data  
1
Press the MENU button 9 times to display the (ALARM  
DATA) menu.  
The first screen (1/13) of alarm data entries is displayed.  
2
3
To display the next screen of alarm data entries, press  
the NEXT button.  
Press the EXIT button to exit the menu display, or  
Press the MENU button to normally picture, then  
press the MENU button once to display the menu  
display.  
1
2
(ALARM DATA)  
1/13  
(ALARM DATA)  
2/13  
CAM DATE TIME ITEM  
CAM DATE TIME ITEM  
1
2
3
4
5
6
7
8
4
2
4
3
1
1
2
4
08-22 08:48  
08-21 08:51  
05-04 16:22  
05-04 07:45  
04-30 14:37  
04-21 18:26  
04-12 05:31  
04-12 12:51  
E
E
E
V
E
V
E
E
9
4
03-29 17:40  
03-26 08:49  
03-13 09:25  
03-05 08:15  
02-11 15:18  
02-29 12:30  
02-21 08:21  
01-15 11:34  
E
V
E
E
E
V
E
E
10 2  
11 4  
12 3  
13 1  
14 1  
15 2  
16 4  
MENU  
ZOOM  
NEXT  
The codes in the ITEM column indicate the type of alarm  
data.  
E: External alarm trigger (see page 25)  
V: Video loss (see page 32)  
NOTE:  
When the number of recorded alarm data entries reaches  
100, the oldest ones are erased as new ones are recorded.  
The alarm data screens are only displayed when alarm data  
entries are recorded.  
English  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ALARMS OPERATIONS  
There are two types of alarms; the alarms set by an external alarm trigger and the alarms set by a loss of the video signal.  
EXTERNAL ALARMS  
VIDEO LOSS ALARM  
When external inputs such as a door bell, an interphone, etc.,  
are connected to the CONTROL terminal (pins 1 4), they will  
send alarm triggers automatically. On the monitor screen, the  
alarm display will identify the camera corresponding to the alarm  
trigger.  
If there is an interruption of the video signal, the buzzer is heard,  
and the image just previous to the interruption is frozen  
on-screen or color bars are displayed and VIDEO LOSSwill  
flash on-screen.  
The action taken will depend on the settings entered in the  
(VIDEO LOSS SET) menu (see page 32).  
Example: If an alarm trigger is received for camera 4  
(in 4 divisions split screen)  
1
2
The buzzer is heard and the camera 4 indicator light.  
The alarm output changes from HI (5V) to LOW (0V).  
VIDEO LOSS  
VIDEO LOSS  
(Color bars)  
The image from camera 4 and the camera number (04)  
will be displayed on monitor 1, EA (External Alarm) will  
flash at the left of the camera number.  
NOTE:  
If a video signal is not present from the beginning, then NO  
VIDEOwill be displayed on a gray screen. This will not  
trigger a video loss alarm.  
The action taken here will depend on the settings entered in  
the (ALARM SET) menu (see page 25).  
The video loss alarm is recorded until the video signal is  
restored.  
Resetting the Alarm  
EA  
04  
For an alarm in full screen display mode, press the  
corresponding camera select button, NO VIDEOwill be  
External alarm  
Camera number  
displayed on a grey screen.  
For an alarm in 4 division split screen display mode, press  
the corresponding camera select button to switch to full  
screen display mode. Then, press the corresponding camera  
select button one more time and NO VIDEOwill be  
displayed on a grey screen.  
NOTE:  
When the alarm operation is over, the display will return to  
the mode preceding the alarm trigger.  
An alarm trigger can also be received at a terminal for which  
a camera is not connected to. In such a case, a grey screen  
will be displayed and EA (External Alarm) and the  
corresponding number will be displayed.  
NOTE:  
The alarm display mode on monitor 1 is selected according to  
the settings entered in the (ALARM SET) menu.  
During normal monitoring operations the camera select  
indicator lights according to the displayed camera. If there is  
an alarm trigger for another camera, the indicator will flash.  
Resetting the Alarm  
For an alarm in full screen display mode, press the  
corresponding camera select button.  
For an alarm in 4 division split screen display mode, press  
the corresponding camera select button to switch to full  
screen display mode then press the corresponding camera  
select button one more time.  
If the alarm is not reset, VIDEO LOSSwill be displayed until  
normal live picture signals are restored.  
NOTE:  
The alarm display mode on monitor 1 is selected according to  
the settings entered in the (MONITOR SET) menu.  
During normal monitoring operations the camera select  
indicator lights according to the displayed camera. If there is  
an alarm trigger for another camera, the indicator will flash.  
34  
English  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS232C CONTROL  
CONNECTION  
COMMANDS  
Connect a 9-pin D-SUB cable (sold separately) from the  
RS232C terminal on the rear panel to the computer serial  
connector.  
COMMANDS AVAILABLE FROM THE  
COMPUTER  
1-4 (90-93)  
Computer  
To select the picture from a camera to be displayed full screen  
on monitor 1.  
CONTROL  
G
C
R1 R2  
C
S
C
A
C
1
2
3
4
C
QUAD (83)  
To display a 4 divisions split screen on monitor 1.  
RS232C  
SEQUENCE (87)  
To switch the display mode from full screen to sequential display  
on monitor 1.  
9-pin D-SUB cable  
(sold separately)  
ZOOM (85)  
To zoom in the picture on monitor 1.  
Setting the Data Transmission Speed  
After the connection is made, set the data transmission speed in  
the (RS232C SET) menu (see page 32).  
STILL (86)  
To freeze the picture on monitor 1.  
LIVE (80)  
To select the live input mode.  
INTERFACE SPECIFICATIONS  
VCR (81)  
For the RS232C terminal specifications, refer to page 4.  
To select the VCR playback input mode.  
MON2 (88)  
DATA FORMAT  
To set the output at monitor 2, it can be used in combination with  
the monitor 1 display.  
Mode  
Asynchronous  
8 bits  
Character length  
MENU (74)  
To display the menu on monitor 1.  
Data transmission  
speed  
2400, 4800, 9600, 19200 bps  
(set in the (RS232C SET) menu)  
Parity check  
Stop bit  
None  
+ (65), (66)  
One bit  
To select settings (ON/OFF, numbers, letters, symbols) in the  
menus.  
TRANSMISSION PROTOCOL  
« (63), 2 (64)  
The transmission is based on 1 byte units. After the computer  
has transmitted 1 byte, it will wait for an answer from this unit,  
then send the following byte of data.  
The command ON (F6) is sent to start, and the command OFF  
(F7) is sent to finish. This unit will receive the commands, and  
will reply to each command by ACK (OA). (Refer to Command  
table 4on page 38.)  
To change selection in the menus. (To move the cursor  
up/down, right/left.)  
NEXT (75)  
To select the sub-menu in (SENSOR SET) and (DISPLAY SET)  
menus.  
EXIT (76)  
To go to the next menu, or to exit the menu mode.  
MENU RESET (E1)  
To reset all the values of the displayed menu to the default  
values.  
CLOCK ADJUST (E0)  
To reset the clock minutes and seconds setting to 00:00.  
SECURITY LOCK ON (69)  
To set the security lock.  
SECURITY LOCK OFF (6A)  
To cancel the security lock.  
English  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS232C CONTROL  
INFORMATION GATHERING COMMANDS  
STATUS SENSE(D7)  
When this command is sent from the computer, this unit will  
send a 5-byte response (see Table 1).  
Third byte  
Bit  
Bit state information  
7
6
5
4
Reserved  
Reserved  
D7  
RXD  
Monitor 2 operation  
Monitor 2 operation  
MON2 setup  
0: Full screen  
1: Sequential display  
0000: Channel 1  
0001: Channel 2  
0010: Channel 3  
0011: Channel 4  
d1  
d2  
d3  
d4  
d5  
TXD  
3
2
1
0
Monitor 2 displayed  
channel  
STATUS SENSE(D7) byte assignment (Table 1)  
Fourth and fifth bytes are reserved.  
First byte  
Bit  
7
Bit state information  
0: LIVE picture mode  
1: VCR playback mode  
000: Full screen  
LIVE/VCR indication  
ALARM STATUS SENSE(D5)  
The external and video loss alarm states are indicated by a  
6-byte response (see Table 2).  
6
5
4
3
2
1
0
Monitor 1 display  
mode indication  
001: 4 divisions split screen  
010: Menu display  
(Full screen mode)  
0000: Channel 1  
D5  
RXD  
Monitor 1 displayed  
channel depending  
on the display mode  
indication  
d1  
d2  
d3  
d4  
d5  
d6  
TXD  
0001: Channel 2  
0010: Channel 3  
ALARM STATUS SENSE(D5) byte assignment  
(Table 2)  
0011: Channel 4  
(4 divisions split screen)  
0000: 4 divisions split screen (channels  
1, 2, 3, 4)  
First byte  
Second byte  
Bit  
Bit  
(Menu display)  
7
6
5
4
3
2
1
0
0
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0000: (LANGUAGE/LANG./IDIO.) menu  
0001: (CLOCK SET) menu  
0010: (TITLE SET) menu  
0011: (ALARM SET) menu  
0100: (SENSOR SET) menu  
0101: (TIMER SET) menu  
0110: (DISPLAY SET) menu  
0111: (VCR SET) menu  
0
0
0
ALARM ON 4  
ALARM ON 3  
ALARM ON 2  
ALARM ON 1  
Third byte  
Fourth byte  
1000: (ALARM DATA) menu  
Bit  
Bit  
Second byte  
7
6
5
4
3
2
1
0
0
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
Bit  
Bit state information  
0
7
EXT/ALARM  
indication  
EXT and ALARM are ON  
0
0
6
VIDEO LOSS  
indication  
VIDEO LOSS is ON  
SENSOR 4  
SENSOR 3  
SENSOR 2  
SENSOR 1  
5
4
3
2
1
0
SENSOR indication  
Reserved  
SENSOR is ON  
0
Monitor 1 display  
state mode indication  
0000: Normal display mode  
0001: Sequential display mode  
0010: Zoomed in mode  
0011: Still image mode  
0100: Frozen zoomed in image  
0101: Zoomed in still image  
0110: Zoom range setting mode  
Fifth byte  
Bit  
Sixth byte  
Bit  
7
6
5
4
3
2
1
0
0
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0111: Zoomed in still image range setting  
mode  
VIDEO LOSS 4  
VIDEO LOSS 3  
VIDEO LOSS 2  
VIDEO LOSS 1  
36  
English  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS232C CONTROL  
COMMANDS AVAILABLE FROM THE  
MULTIPLEXER  
ACK(0A)  
Response when this unit receives a command.  
NAK(0B)  
Response if this unit did not receive the command.  
ALARM(BF)  
When there is an alarm, this command is sent as header. Then,  
the alarm information is sent in a 1-byte transmission (see Table  
3).  
ALARM information (Table 3)  
Bit  
7
Bit state information  
01: External  
Alarm information  
indication  
6
10: Video loss  
11: Sensor alarm  
0
5
4
3
2
1
0
Reserved  
Reserved  
0
Camera number  
indication  
0011: CAMERA NO. 4  
0010: CAMERA NO. 3  
0001: CAMERA NO. 2  
0000: CAMERA NO. 1  
OTHER COMMANDS  
ENTER(40)  
When numeric commands are all sent, this command is used to  
enter the transmitted value.  
CLEAR(56)  
To erase multiple byte commands.  
English  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS232C CONTROL  
COMMAND TABLE (TABLE 4)  
The commands available are indicated in the table.  
If a function is not available on the unit, the command will not operate even if sent.  
0
1
2
3
0
1
2
3
4
5
6
7
8
9
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
ENTER  
LIVE  
FULL 1  
FULL 2  
FULL 3  
FULL 4  
VCR PB  
(MULTI)  
QUAD  
PLUS  
ZOOM  
STILL  
SEQ.  
VERSION  
SHIFT  
MENU  
NEXT  
»
1
«
O
+
CLEAR  
EXIT  
MON 2  
SECURITY LOCK ON  
SECURITY LOCK OFF  
ACK  
NAK  
(POWER ON/OFF)  
(SET ON)  
(SET OFF)  
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
CLK. ADJ.  
MENU RESET  
ALARM STATUS SENSE  
STATUS SENSE  
ALARM  
38  
English  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
Signal format  
: Based on NTSC color signal standard (MPX-CD4)  
Based on NTSC B/W signal standard (MPX-MD4)  
Camera signal input synchronization  
Camera input terminals (IN)  
Camera output terminals (OUT)  
VCR input terminal (VCR IN)  
: Asynchronous  
: VS/VBS, 1.0 Vp-p/75 , BNC connector x 4  
: Throughput of each input, 1.0 Vp-p/75 , BNC connector x 4  
Composite input  
: VS/VBS, 1.0 Vp-p/75 , BNC connector x 1  
S-VHS input terminal (S-VHS VCR IN) : Separate YC signals, DIN connector (S terminal) x 1 (MPX-CD4 only)  
Y signal: 1.0 Vp-p/75 , unbalanced, synchronous; C signal: 0.286 Vp-p/75 ,  
unbalanced  
VCR output terminal (VCR OUT)  
Composite output  
S-VHS output terminal (S-VHS VCR  
OUT)  
: VS/VBS, 1.0 Vp-p/75 , BNC connector x 1  
: Separate YC signals, DIN connector (S terminal) x 1 (MPX-CD4 only)  
Y signal: 1.0 Vp-p/75 , unbalanced, synchronous; C signal: 0.286 Vp-p/75 ,  
unbalanced  
Monitor 1 output terminal (MONITOR OUT 1) : VS/VBS, 1.0 Vp-p/75 , BNC connector x 1  
Separate YC signals, DIN connector (S terminal) x 1 (MPX-CD4 only)  
Y signal: 1.0 Vp-p/75 , unbalanced, synchronous; C signal: 0.286 Vp-p/75 ,  
unbalanced  
Camera live picture or VCR playback picture signal output: full screen, sequential  
display, 4 divisions split screen  
Monitor 2 output terminal (MONITOR OUT 2) : VS/VBS, 1.0 Vp-p/75 , BNC connector x 1  
Camera live picture signal output: full screen (can be set in (MONITOR SET) menu  
to display the same image as monitor 1)  
Control terminal (CONTROL)  
Alarm input (1 4)  
Remote input (R1, R2)  
Alarm output (A)  
Switching input (S)  
: No voltage, make-contact switch input x 4 (Low input)  
: 2-wire type with resistance-based identification system  
: DC 5 V, 5.7 k(Low output)  
: Low input, for input signal from SW OUT of timelapse VCR/real time recorder (as  
per this manufacturer specifications)  
RS-232C terminal  
: 9-pin D-SUB  
Full screen sequence timing  
Monitor on-screen display  
Menu settings  
: Available in full screen, 8 settings (1, 2, 3, 4, 5, 10, 20, 30 sec.)  
: Title (up to 10 characters), date, time selectable  
: 9 menus: Language, Clock, Title, Alarm, Sensor, Timer, Display, VCR, Alarm data  
: Internal, 4 channel (each camera input, selectable)  
Alarm sensor  
Back-up function  
: Back-up for up to 30 days of the clock settings after connected for 30 hours  
continuously  
Operations  
Still  
: Available for camera live or VCR playback in 4 divisions split screen, full screen and  
zoomed in picture  
Can be set using a menu to operate automatically when there is an alarm trigger  
Zoom  
: Available for camera live or VCR playback in 4 divisions split screen, full screen and  
frozen picture  
In full screen mode can switch from frozen to zoomed in picture  
: AC 120 V, 60 Hz  
Power  
Consumption  
Operating environment  
Dimensions  
Weight  
: 19 W (MPX-CD4), 14 W (MPX-MD4)  
: Temperature: 5 to 40˚C, Humidity: 10 to 80%  
: 420 (W) x 44 (H) x 325 (D) mm  
: Approx. 3.4 kg  
Products are subject to change in design and specifications without notice and without incurring any obligation.  
English  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANYO INDUSTRIAL  
MULTIPLEXER LIMITED WARRANTY  
OBLIGATIONS  
In order to obtain warranty service, the product must be delivered to and picked up from an Authorized Sanyo Service Center at the users  
expense, unless specifically stated otherwise in this warranty. The names and addresses of Authorized Sanyo Service Centers may be  
obtained by writing to SFS Corporation, SFCs warranty administrator, at any of the addresses listed below, or by calling (toll-free)  
1-800-421-5013.  
New Jersey Office  
California Office  
Illinois Office  
210 Riser Road Little Ferry, NJ 07643  
1200 W. Artesia Blvd. Compton, CA 90220  
900 N. Arlington Heights Rd. Itasca, IL 60143  
201-641-3000  
310-537-5830  
708-775-1414  
THIS WARRANTY IS VALID ONLY ON SANYO PRODUCTS PURCHASED OR RENTED IN THE UNITED STATES OF AMERICA,  
EXCLUDING HAWAII AND ALL U.S. TERRITORIES AND PROTECTORATES. THIS WARRANTY APPLIES ONLY TO THE ORIGINAL  
RETAIL USER. THE ORIGINAL DATED BILL OF SALE, SALES SLIP OR RENTAL AGREEMENT MUST BE SUBMITTED TO THE  
AUTHORIZED SANYO SERVICE CENTER AT THE TIME WARRANTY SERVICE IS REQUESTED.  
Subject to the OBLIGATIONS above and EXCLUSIONS below, SANYO FISHER (USA) CORPORATION warrants this SANYO product  
against defects in materials and workmanship for the periods specified below. SFC will repair or replace (at its option) the product and any of  
its parts which fail to conform to this warranty. The warranty period commences on the date the product was first purchased or rented at retail.  
LABOR  
PARTS  
3 YEARS  
3 YEARS  
EXCLUSIONS  
This warranty does not cover (A) the adjustment of customer-operated controls as explained in the appropriate models instruction manual, or  
(B) the repair of any product whose serial number has been altered, defaced or removed.  
This warranty shall not apply to the cabinet or cosmetic parts, broken or damaged video heads, knobs or routine maintenance.  
This warranty does not apply to uncrating, setup, installation, removal of the product for repair or reinstallation of the product after repair.  
This warranty does not apply to repairs or replacements necessitated by any cause beyond the control of SFC including, but not limited to, any  
malfunction, defect or failure caused by or resulting from unauthorized service or parts, improper maintenance, operation contrary to furnished  
instructions, shipping or transit accidents, modification or repair by the user, abuse, misuse, neglect, accident, incorrect power line voltage,  
fire, flood or other Acts of God, or normal wear and tear.  
The foregoing is in lieu of all other expressed warranties and SFC does not assume or authorize any party to assume for it any other  
obligation or liability.  
THE DURATION OF ANY WARRANTIES WHICH MAY BE IMPLIED BY LAW (INCLUDING THE WARRANTIES OF MERCHANTABILITY  
AND FITNESS) IS LIMITED TO THE TERM OF THIS WARRANTY. IN NO EVENT SHALL SFC BE LIABLE FOR SPECIAL, INCIDENTAL  
OR CONSEQUENTIAL DAMAGES ARISING FROM OWNERSHIP OR USE OF THIS PRODUCT, OR FOR ANY DELAY IN THE  
PERFORMANCE OF ITS OBLIGATIONS UNDER THIS WARRANTY DUE TO CAUSES BEYOND ITS CONTROL. SOME STATES DO NOT  
ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS AND/OR DO NOT ALLOW THE EXCLUSION OR LIMITATION  
OF CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO YOU.  
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY HAVE OTHER RIGHTS, WHICH VARY FROM STATE TO STATE.  
ATTENTION  
For your protection in the event of theft or loss of this product, please fill in the information below for you own personal records.  
Model No. _____________________________________________  
Date of Purchase _______________________________________  
Serial No.______________________________________________  
(Located on back or bottom side of unit.)  
Purchase Price _________________________________________  
Where Purchased _________________________________________________________________________________________________  
21350 Lassen Street,  
1AC6P1P1003– –  
EA4Q/U2  
Chatsworth, CA 91311  
(1195KP-SY01)  
Issue No. 1  
Copyright SANYO, 1995 All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Printed in Japan  

Radica Games Games 75006 User Guide
RIDGID Pressure Washer RD80763 User Guide
Roper Range FGP31OE User Guide
Samsung Car Video System 743BM User Guide
Samsung Cash Register SAM52 User Guide
Samsung CRT Television 521 User Guide
Sanus Systems Appliance Trim Kit VMCC1 User Guide
Sanyo Freezer MDF 593C User Guide
Savin Fax Machine 3699 User Guide
Schumacher Battery Charger SC 200A User Guide