Sanyo Car Speaker KH2442 CH2442 User Guide

TECHNICAL DATA  
&
SERVICE MANUAL  
FILE NO.  
XH2442 / CH2442 KH2442 / CH2442  
XH3642 / CH3642 KH3642 / CH3642  
XH4242 / CH4242  
TH2442 / CH2442 UH2442 / CH2442  
TH3642 / CH3642 UH3642 / CH3642  
TH4242 / CH4242  
SPLIT SYSTEM AIR CONDITIONER  
Section  
INDOOR MODEL No.  
XH2442  
PRODUCT CODE No.  
854 017 11  
854 017 12  
854 017 13  
854 017 14  
854 017 15  
854 017 16  
854 017 07  
854 017 08  
854 017 19  
854 017 20  
OUTDOOR MODEL No.  
CH2442  
PRODUCT CODE No.  
854 017 21  
1
XH3642  
CH3642  
854 017 22  
XH4242  
CH4242  
854 017 23  
TH2442  
TH3642  
TH4242  
KH2442  
KH3642  
2
3
4
5
UH2442  
UH3642  
Indoor Unit  
Outdoor Unit  
TH2442  
TH3642  
TH4242  
CH2442  
XH2442  
XH3642  
XH4242  
UH2442  
UH3642  
KH2442  
KH3642  
CH3642  
CH4242  
85464849182000  
REFERENCE NO. SM830082  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WHO SHOULD USE THIS MANUAL  
This service manual is made to assist the service technician apply his knowledge and training  
to this model air conditioner. This manual is written both for experienced service persons  
and those who are new to air conditioning service. To help those with less experience or  
who are new to this kind of unit we have included more explanations of basic procedures in  
simple language than is usual in some service manuals. The experienced technician will of  
course find he knows many of these things already and can go directly to the procedures and  
information he needs; the less experienced technician will better understand what to do even  
before he arrives on the job, and therefore be better able to work by himself as well as assist  
the more experienced technician.  
TABLE OF CONTENTS  
1. SPECIFICATIONS............................................................................................ I - 1  
1-1 Unit Specifications .....................................................................................I - 2  
1-2 Major Component Specifications ...............................................................I - 12  
(A) Indoor Units ..................................................................................................I - 12  
(B) Outdoor Units ...............................................................................................I - 22  
1-3 Other Component Specifications ...............................................................I - 25  
1-4 Dimensional Data ......................................................................................I - 38  
(A) Indoor Units ..................................................................................................I - 38  
(B) Outdoor Units ...............................................................................................I - 47  
1-5 Refrigerant Flow Diagram..........................................................................I - 49  
1-6 Operating Range .......................................................................................I - 50  
1-7 Cooling Capacity........................................................................................I - 51  
1-8 Heating Capacity .......................................................................................I - 71  
1-9 Performance Charts...................................................................................I - 72  
1-10 Noise Criterion Curves...............................................................................I - 90  
1-11 Increasing the Fan Speed..........................................................................I - 95  
1-12 Air throw Distance Chart............................................................................I - 96  
1-13 Installation Instructions ..............................................................................I - 99  
2. PROCESSES AND FUNCTIONS ......................................................................II - 1  
2-1 Room Temperature Control ......................................................................II - 2  
2-2 Cold Draft Prevention (Heating Cycle)......................................................II - 4  
2-3 Automatic Fan Speed (Indoor Unit) ..........................................................II - 5  
2-4 Outdoor Fan Speed Control......................................................................II - 6  
2-5 Freeze Prevention (Cooling).....................................................................II - 7  
2-6 Condensing Temperature Control (Cooling).............................................II - 8  
SM830082  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2-7 Overload Protection (Heating) ..................................................................II - 9  
2-8 Discharge Temperature Control (Cooling and Heating) ...........................II - 10  
2-9 Auto. Mode for Automatic Heating/Cooling Switching ..............................II - 11  
2-10 Defrosting Control, Outdoor Heat Exchanger Coil (Heating) ....................II - 13  
2-11 4-Way Valve, Solenoid Control.................................................................II - 14  
2-12 Automatic Restart after Power Interruption...............................................II - 15  
2-13 Electronic Expansion Control Valve..........................................................II - 16  
2-14 Compressor Discharge Gas Temperature................................................II - 16  
2-15 Compressor Current Detection Circuit......................................................II - 17  
2-16 Electronic Expansion Valve ......................................................................II - 18  
2-17 Voltage Detection Control.........................................................................II - 19  
3. ELECTRICAL DATA ........................................................................................III - 1  
3-1 Indoor Unit (Electric Wiring Diagram, Schematic Diagram).....................III - 2  
3-2 Outdoor Unit (Electric Wiring Diagram, Schematic Diagram) ..................III - 12  
4. SERVICE PROCEDURES............................................................................... IV - 1  
4-1 Troubleshooting ...................................................................................... IV - 2  
4-2 Checking the Electrical Components...................................................... IV - 30  
SM830082  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. SPECIFICATIONS  
1-1 Unit Specifications ................................................................................. I -  
4-Way Air Discharge Semi-concealed Type ...........................................I -  
Ceiling Mounted Type..............................................................................I -  
Concealed Duct Type ..............................................................................I -  
2
2
5
8
Wall-Mounted Type..................................................................................I - 10  
1-2 Major Component Specifications .............................................................I - 12  
(A) Indoor Units ........................................................................................I - 12  
(B) Outdoor Units .....................................................................................I - 22  
1-3 Other Component Specifications .............................................................I - 25  
4-Way Air Discharge Semi-concealed Type ...........................................I - 25  
Ceiling Mounted Type..............................................................................I - 28  
Concealed Duct Type ..............................................................................I - 31  
Wall-Mounted Type..................................................................................I - 33  
Outdoor Units...........................................................................................I - 35  
1-4 Dimensional Data ....................................................................................I - 38  
(A) Indoor Units ........................................................................................I - 38  
4-Way Air Discharge Semi-concealed Type....................................... I - 38  
Ceiling Mounted Type ........................................................................I - 40  
Concealed Duct Type.........................................................................I - 42  
Wall-Mounted Type ............................................................................I - 45  
(B)Outdoor Units .....................................................................................I - 47  
1-5 Refrigerant Flow Diagram ........................................................................I - 49  
1-6 Operating Range .....................................................................................I - 50  
1-7 Cooling Capacity......................................................................................I - 51  
1-8 Heating Capacity .....................................................................................I - 71  
1-9 Performance Charts.................................................................................I - 72  
(1) Operating Current...............................................................................I - 72  
(2) Operating Pressure ............................................................................I - 84  
1-10 Noise Criterion Curves.............................................................................I - 90  
1-11 Increasing the Fan Speed........................................................................I - 95  
1-12 Air throw distance chart ...........................................................................I - 96  
1-13 Installation Instructions ............................................................................I - 99  
Tubing Length ..........................................................................................I - 99  
SELECTING THE INSTALLATION SITE.................................................I -100  
ELECTRICAL WIRING ............................................................................I -104  
Electrical characteristics ..........................................................................I -108  
1
SM830082  
I - 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-1 Unit Specifications  
MODEL No.  
Indoor Unit  
XH2442  
CH2442  
Outdoor Unit  
POWER SOURCE  
PERFORMANCE  
Capacity*  
230 - 208 V / 1 Phase / 60 Hz  
Cooling  
Heating  
BTU / h  
24,000  
8.6  
23,400  
8.4  
25,000  
16,400  
24,300  
15,800  
(17°F)**  
Moisture removal (High)  
Air circulation (H / M / L)  
S.E.E.R. (H.S.P.F.)  
Pints / h  
cu.ft. / min.  
BTU / Wh  
230 V  
710 / 530 / 450  
10.0  
230  
10.2  
208  
(7.0)  
(7.0)  
208  
ELECTRICAL RATINGS  
Voltage rating  
VAC  
VAC  
A
230  
Available voltage range  
Running amperes  
187 - 253  
11.2  
11.6  
11.7  
12.3  
Power input*  
W
2,450  
2,350  
2,500  
2,150  
2,450  
2,020  
(17°F)**  
Maximum overcurrent protection  
FEATURES  
A
25  
Controls  
Microprocessor  
Low ambient control  
Fan speeds Indoor / Outdoor  
Built-in 0°F  
3 and Automatic control / 3 (Auto)  
1
Optional Wired Remote Controller (Timer)  
Optional Wireless Remote Controller (Timer)  
Air deflection  
RCS-SH80UG (72-hour ON / OFF)  
RCS-SH80UA. WL / RCS-BH80UA. WL (72-hour ON / OFF)  
— / Automatic  
Horizontal / Vertical  
Air filter  
Washable, easy access, long life fiter (2,500 hr)  
Operation sound  
Indoor - Hi / Me / Lo  
Outdoor - Hi  
dB - A  
dB - A  
38 / 35 / 31  
53  
Refrigerant control  
Electronic Expansion Control Valve  
REFRIGERANT PIPING  
Limit of piping length  
ft.  
ft.  
ft.  
(m)  
(m)  
(m)  
165 (50)  
100 (30)  
Limit of piping length at shipment  
Limit of elevation difference  
between the two units  
Outdoor unit is higher than indoor unit: 165 (50)  
Outdoor unit is lower than indoor unit: 100 (30)  
Refrigerant piping  
Flare type  
Narrow pipe  
Wide pipe  
in. (mm)  
in. (mm)  
1 / 4 (6.35)  
3 / 4 (19.05)  
DIMENSIONS & WEIGHT  
Indoor unit  
12-1/8  
Outdoor unit  
28-15/16  
Unit dimensions  
Height  
Width  
Depth  
in. (mm)  
in. (mm)  
in. (mm)  
lbs. (kg)  
in. (mm)  
in. (mm)  
in. (mm)  
lbs. (kg)  
in. (mm)  
in. (mm)  
in. (mm)  
lbs. (kg)  
cu.ft. (m3)  
in. (mm)  
in. (mm)  
in. (mm)  
lbs. (kg)  
cu.ft. (m3)  
(380)  
(776)  
(776)  
(22)  
(735)  
(940)  
(340)  
(71)  
30-9/16  
30-9/16  
49  
37-1/32  
13-3/8  
157  
Net weight  
Indoor grille dimensions  
PNR-XHS2432  
Height  
Width  
Depth  
3-1/16  
33-27/32  
33-27/32  
11  
(78)  
(860)  
(860)  
(5)  
Net weight  
Indoor / Outdoor unit  
Package dimensions  
Height  
Width  
Depth  
13-5/16  
32-7/8  
33-9/32  
57  
(338)  
(835)  
(845)  
(26)  
32-17/32  
40  
(826)  
(1,016)  
(416)  
16-3/8  
170  
Shipping weight  
Shipping volume  
Indoor grille  
(77)  
8.4  
(0.238)  
(104)  
(964)  
(999)  
(8)  
12.3  
(0.349)  
Height  
Width  
Depth  
4-3/32  
37-15/16  
39-11/32  
18  
Package dimensions  
PNR-XHS2432  
Shipping weight  
Shipping volume  
3.5  
(0.100)  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
Cooling :  
Rating conditions (*)  
Heating :  
Rating conditions (*)  
: Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB  
: Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB  
Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB  
SM830082  
I - 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-1 Unit Specifications  
MODEL No.  
Indoor Unit  
XH3642  
CH3642  
Outdoor Unit  
POWER SOURCE  
PERFORMANCE  
Capacity*  
230 - 208 V / 1 Phase / 60 Hz  
Cooling  
Heating  
BTU / h  
34,500  
10.5  
33,500  
10.6  
37,500  
25,000  
36,500  
23,500  
(17°F)**  
Moisture removal (High)  
Air circulation (H / M / L)  
S.E.E.R. (H.S.P.F.)  
Pints / h  
cu.ft. / min.  
BTU / Wh  
230 V  
1,050 / 840 / 720  
10.7  
230  
11.0  
208  
(7.0)  
(7.0)  
208  
ELECTRICAL RATINGS  
Voltage rating  
VAC  
VAC  
A
230  
Available voltage range  
Running amperes  
187 - 253  
15.4  
15.8  
18.2  
19.3  
Power input*  
W
3,350  
3,200  
3,850  
3,150  
3,750  
2,950  
(17°F)**  
Maximum overcurrent protection  
FEATURES  
A
40  
Controls  
Microprocessor  
Low ambient control  
Fan speeds Indoor / Outdoor  
Built-in 0°F  
3 and Automatic control / 3 (Auto)  
1
Optional Wired Remote Controller (Timer)  
Optional Wireless Remote Controller (Timer)  
Air deflection  
RCS-SH80UG (72-hour ON / OFF)  
RCS-SH80UA. WL / RCS-BH80UA. WL (72-hour ON / OFF)  
— / Automatic  
Horizontal / Vertical  
Air filter  
Washable, easy access, long life fiter (2,500 hr)  
Operation sound  
Indoor - Hi / Me / Lo  
Outdoor - Hi  
dB - A  
dB - A  
44 / 37 / 33  
56  
Refrigerant control  
Electronic Expansion Control Valve  
REFRIGERANT PIPING  
Limit of piping length  
ft.  
ft.  
ft.  
(m)  
(m)  
(m)  
165 (50)  
100 (30)  
Limit of piping length at shipment  
Limit of elevation difference  
between the two units  
Outdoor unit is higher than indoor unit: 165 (50)  
Outdoor unit is lower than indoor unit: 100 (30)  
Refrigerant piping  
Flare type  
Narrow pipe  
Wide pipe  
in. (mm)  
in. (mm)  
3 / 8 (9.52)  
3 / 4 (19.05)  
DIMENSIONS & WEIGHT  
Indoor unit  
14-1/2  
Outdoor unit  
48-5/8  
Unit dimensions  
Height  
Width  
Depth  
in. (mm)  
in. (mm)  
in. (mm)  
lbs. (kg)  
in. (mm)  
in. (mm)  
in. (mm)  
lbs. (kg)  
in. (mm)  
in. (mm)  
in. (mm)  
lbs. (kg)  
cu.ft. (m3)  
in. (mm)  
in. (mm)  
in. (mm)  
lbs. (kg)  
cu.ft. (m3)  
(368)  
(1,066)  
(776)  
(27)  
(1,235)  
(940)  
(340)  
(92)  
41-31/32  
30-9/16  
60  
37-1/32  
13-3/8  
203  
Net weight  
Indoor grille dimensions  
PNR-XHS2432  
Height  
Width  
Depth  
3-1/16  
45-9/32  
33-27/32  
15  
(78)  
(1,150)  
(860)  
(7)  
Net weight  
Indoor / Outdoor unit  
Package dimensions  
Height  
Width  
Depth  
14-1/2  
44-9/32  
33-9/32  
71  
(368)  
(1,125)  
(845)  
(32)  
52-7/32  
40  
(1,326)  
(1,016)  
(416)  
16-3/8  
227  
Shipping weight  
Shipping volume  
Indoor grille  
(103)  
12.4  
(0.35)  
(104)  
(1,257)  
(999)  
(10)  
19.8  
(0.56)  
Height  
Width  
Depth  
4-3/32  
49-1/2  
39-11/32  
22  
Package dimensions  
PNR-XHS2432  
Shipping weight  
Shipping volume  
4.6  
(0.131)  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
Cooling :  
Rating conditions (*)  
Heating :  
Rating conditions (*)  
: Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB  
: Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB  
Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB  
SM830082  
I - 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-1 Unit Specifications  
MODEL No.  
Indoor Unit  
XH4242  
CH4242  
Outdoor Unit  
POWER SOURCE  
PERFORMANCE  
Capacity*  
230 - 208 V / 1 Phase / 60 Hz  
Cooling  
Heating  
BTU / h  
42,000  
14.4  
40,000  
14.0  
44,000  
28,000  
42,000  
26,000  
(17°F)**  
Moisture removal (High)  
Air circulation (H / M / L)  
S.E.E.R. (H.S.P.F.)  
Pints / h  
cu.ft. / min.  
BTU / Wh  
230 V  
1,050 / 840 / 720  
10.4  
230  
10.4  
208  
(7.0)  
(7.0)  
208  
ELECTRICAL RATINGS  
Voltage rating  
VAC  
VAC  
A
230  
Available voltage range  
Running amperes  
187 - 253  
20.6  
21.0  
21.7  
22.2  
Power input*  
W
4,200  
4,100  
4,450  
3,700  
4,350  
3,550  
(17°F)**  
Maximum overcurrent protection  
FEATURES  
A
45  
Controls  
Microprocessor  
Low ambient control  
Fan speeds Indoor / Outdoor  
Built-in 0°F  
3 and Automatic control / 3 (Auto)  
1
Optional Wired Remote Controller (Timer)  
Optional Wireless Remote Controller (Timer)  
Air deflection  
RCS-SH80UG (72-hour ON / OFF)  
RCS-SH80UA. WL / RCS-BH80UA. WL (72-hour ON / OFF)  
— / Automatic  
Horizontal / Vertical  
Air filter  
Washable, easy access, long life fiter (2,500 hr)  
Operation sound  
Indoor - Hi / Me / Lo  
Outdoor - Hi  
dB - A  
dB - A  
45 / 38 / 34  
56  
Refrigerant control  
Electronic Expansion Control Valve  
REFRIGERANT PIPING  
Limit of piping length  
ft.  
ft.  
ft.  
(m)  
(m)  
(m)  
165 (50)  
100 (30)  
Limit of piping length at shipment  
Limit of elevation difference  
between the two units  
Outdoor unit is higher than indoor unit: 165 (50)  
Outdoor unit is lower than indoor unit: 100 (30)  
Refrigerant piping  
Flare type  
Narrow pipe  
Wide pipe  
in. (mm)  
in. (mm)  
3 / 8 (9.52)  
3 / 4 (19.05)  
DIMENSIONS & WEIGHT  
Indoor unit  
14-1/2  
Outdoor unit  
48-5/8  
Unit dimensions  
Height  
Width  
Depth  
in. (mm)  
in. (mm)  
in. (mm)  
lbs. (kg)  
in. (mm)  
in. (mm)  
in. (mm)  
lbs. (kg)  
in. (mm)  
in. (mm)  
in. (mm)  
lbs. (kg)  
cu.ft. (m3)  
in. (mm)  
in. (mm)  
in. (mm)  
lbs. (kg)  
cu.ft. (m3)  
(368)  
(1,066)  
(776)  
(27)  
(1,235)  
(940)  
(340)  
(92)  
41-31/32  
30-9/16  
60  
37-1/32  
13-3/8  
203  
Net weight  
Indoor grille dimensions  
PNR-XHS2432  
Height  
Width  
Depth  
3-1/16  
45-9/32  
33-27/32  
15  
(78)  
(1,150)  
(860)  
(7)  
Net weight  
Indoor / Outdoor unit  
Package dimensions  
Height  
Width  
Depth  
14-1/2  
44-9/32  
33-9/32  
71  
(368)  
(1,125)  
(845)  
(32)  
52-7/32  
40  
(1,326)  
(1,016)  
(416)  
16-3/8  
227  
Shipping weight  
Shipping volume  
Indoor grille  
(103)  
12.4  
(0.35)  
(104)  
(1,257)  
(999)  
(10)  
19.8  
(0.56)  
Height  
Width  
Depth  
4-3/32  
19-1/2  
39-11/32  
22  
Package dimensions  
PNR-XHS2432  
Shipping weight  
Shipping volume  
4.6  
(0.131)  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
Cooling :  
Rating conditions (*)  
Heating :  
Rating conditions (*)  
: Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB  
: Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB  
Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB  
SM830082  
I - 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-1 Unit Specifications  
MODEL No.  
Indoor Unit  
TH2442  
CH2442  
Outdoor Unit  
POWER SOURCE  
PERFORMANCE  
Capacity*  
230 - 208 V / 1 Phase / 60 Hz  
Cooling  
Heating  
BTU / h  
22,400  
8.0  
21,600  
7.9  
25,400  
15,700  
25,000  
15,000  
(17°F)**  
Moisture removal (High)  
Air circulation (H / M / L)  
S.E.E.R. (H.S.P.F.)  
Pints / h  
cu.ft. / min.  
BTU / Wh  
230 V  
550 / 490 / 460  
10.0  
230  
10.0  
208  
(7.0)  
(7.0)  
208  
ELECTRICAL RATINGS  
Voltage rating  
VAC  
VAC  
A
230  
Available voltage range  
Running amperes  
187 - 253  
10.7  
11.3  
11.7  
12.9  
Power input*  
W
2,350  
2,280  
2,550  
2,070  
2,500  
2,040  
(17°F)**  
Maximum overcurrent protection  
FEATURES  
A
25  
Controls  
Microprocessor  
Low ambient control  
Fan speeds Indoor / Outdoor  
Built-in 0°F  
3 and Automatic control / 3 (Auto)  
1
Optional Wired Remote Controller (Timer)  
Optional Wireless Remote Controller (Timer)  
Air deflection  
RCS-SH80UG (72-hour ON / OFF)  
RCS-SH80UA. WL / RCS-BH80UA. WL (72-hour ON / OFF)  
Manual / Automatic  
Horizontal / Vertical  
Air filter  
Washable, easy access  
Operation sound  
Indoor - Hi / Me / Lo  
Outdoor - Hi  
dB - A  
dB - A  
40 / 38 / 36  
53  
Refrigerant control  
Electronic Expansion Control Valve  
REFRIGERANT PIPING  
Limit of piping length  
ft.  
ft.  
ft.  
(m)  
(m)  
(m)  
165 (50)  
100 (30)  
Limit of piping length at shipment  
Limit of elevation difference  
between the two units  
Outdoor unit is higher than indoor unit: 165 (50)  
Outdoor unit is lower than indoor unit: 100 (30)  
Refrigerant piping  
Flare type  
Narrow pipe  
Wide pipe  
in. (mm)  
in. (mm)  
1 / 4 (6.35)  
3 / 4 (19.05)  
DIMENSIONS & WEIGHT  
Indoor unit  
7-15/32  
Outdoor unit  
28-15/16  
Unit dimensions  
Height  
Width  
Depth  
Height  
Width  
Depth  
in. (mm)  
in. (mm)  
in. (mm)  
in. (mm)  
in. (mm)  
in. (mm)  
lbs. (kg)  
lbs. (kg)  
cu.ft. (m3)  
(190)  
(1,300)  
(670)  
(735)  
(940)  
(340)  
(826)  
(1,016)  
(416)  
(71)  
51-3/16  
26-3/8  
9-7/16  
54-19/32  
29-31/32  
60  
37-1/32  
13-3/8  
32-17/32  
40  
Indoor grille dimensions  
(240)  
(1,387)  
(761)  
16-3/8  
157  
Net weight  
(27)  
Shipping weight  
Shipping volume  
77  
(35)  
170  
(77)  
8.9  
(0.253)  
12.3  
(0.349)  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
Cooling :  
Rating conditions (*)  
Heating :  
Rating conditions (*)  
: Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB  
: Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB  
Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB  
SM830082  
I - 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-1 Unit Specifications  
MODEL No.  
Indoor Unit  
TH3642  
CH3642  
Outdoor Unit  
POWER SOURCE  
PERFORMANCE  
Capacity*  
230 - 208 V / 1 Phase / 60 Hz  
Cooling  
Heating  
BTU / h  
34,000  
10.7  
33,000  
10.8  
40,000  
25,000  
39,000  
24,000  
(17°F)**  
Moisture removal (High)  
Air circulation (H / M / L)  
S.E.E.R. (H.S.P.F.)  
Pints / h  
cu.ft. / min.  
BTU / Wh  
230 V  
1,100 / 930 / 750  
10.4  
230  
10.7  
208  
(7.3)  
(7.3)  
208  
ELECTRICAL RATINGS  
Voltage rating  
VAC  
VAC  
A
230  
Available voltage range  
Running amperes  
187 - 253  
15.1  
15.7  
18.2  
19.6  
Power input*  
W
3,350  
3,170  
3,950  
3,000  
3,890  
2,900  
(17°F)**  
Maximum overcurrent protection  
FEATURES  
A
40  
Controls  
Microprocessor  
Low ambient control  
Fan speeds Indoor / Outdoor  
Built-in 0°F  
3 and Automatic control / 3 (Auto)  
1
Optional Wired Remote Controller (Timer)  
Optional Wireless Remote Controller (Timer)  
Air deflection  
RCS-SH80UG (72-hour ON / OFF)  
RCS-SH80UA. WL / RCS-BH80UA. WL (72-hour ON / OFF)  
Manual / Automatic  
Horizontal / Vertical  
Air filter  
Washable, easy access  
Operation sound  
Indoor - Hi / Me / Lo  
Outdoor - Hi  
dB - A  
dB - A  
46 / 42 / 37  
56  
Refrigerant control  
Electronic Expansion Control Valve  
REFRIGERANT PIPING  
Limit of piping length  
ft.  
ft.  
ft.  
(m)  
(m)  
(m)  
165 (50)  
100 (30)  
Limit of piping length at shipment  
Limit of elevation difference  
between the two units  
Outdoor unit is higher than indoor unit: 165 (50)  
Outdoor unit is lower than indoor unit: 100 (30)  
Refrigerant piping  
Flare type  
Narrow pipe  
Wide pipe  
in. (mm)  
in. (mm)  
3 / 8 (9.52)  
3 / 4 (19.05)  
DIMENSIONS & WEIGHT  
Indoor unit  
9-7/16  
Outdoor unit  
Unit dimensions  
Height  
Width  
Depth  
Height  
Width  
Depth  
in. (mm)  
in. (mm)  
in. (mm)  
in. (mm)  
in. (mm)  
in. (mm)  
lbs. (kg)  
lbs. (kg)  
cu.ft. (m3)  
(240)  
(1,575)  
(670)  
(317)  
(1,678)  
(789)  
(41)  
48-5/8  
(1,235)  
(940)  
62-1/32  
26-3/8  
12-15/32  
66-1/16  
31-1/16  
90  
37-1/32  
13-3/8  
52-7/32  
40  
(340)  
Indoor grille dimensions  
(1,326)  
(1,016)  
(416)  
16-3/8  
203  
Net weight  
(92)  
Shipping weight  
Shipping volume  
104  
(47)  
227  
(103)  
14.8  
(0.42)  
19.8  
(0.56)  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
Cooling :  
Rating conditions (*)  
Heating :  
Rating conditions (*)  
: Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB  
: Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB  
Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB  
SM830082  
I - 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-1 Unit Specifications  
MODEL No.  
Indoor Unit  
TH4242  
CH4242  
Outdoor Unit  
POWER SOURCE  
PERFORMANCE  
Capacity*  
230 - 208 V / 1 Phase / 60 Hz  
Cooling  
Heating  
BTU / h  
42,000  
14.8  
40,000  
14.3  
44,000  
28,000  
42,000  
26,000  
(17°F)**  
Moisture removal (High)  
Air circulation (H / M / L)  
S.E.E.R. (H.S.P.F.)  
Pints / h  
cu.ft. / min.  
BTU / Wh  
230 V  
1,100 / 930 / 750  
10.0  
230  
10.4  
208  
(7.0)  
(7.0)  
208  
ELECTRICAL RATINGS  
Voltage rating  
VAC  
VAC  
A
230  
Available voltage range  
Running amperes  
187 - 253  
20.6  
21.3  
21.7  
22.5  
Power input*  
W
4,300  
4,200  
4,450  
3,700  
4,350  
3,550  
(17°F)**  
Maximum overcurrent protection  
FEATURES  
A
45  
Controls  
Microprocessor  
Low ambient control  
Fan speeds Indoor / Outdoor  
Built-in 0°F  
3 and Automatic control / 3 (Auto)  
1
Optional Wired Remote Controller (Timer)  
Optional Wireless Remote Controller (Timer)  
Air deflection  
RCS-SH80UG (72-hour ON / OFF)  
RCS-SH80UA. WL / RCS-BH80UA. WL (72-hour ON / OFF)  
Manual / Automatic  
Horizontal / Vertical  
Air filter  
Washable, easy access  
Operation sound  
Indoor - Hi / Me / Lo  
Outdoor - Hi  
dB - A  
dB - A  
47 / 43 / 38  
56  
Refrigerant control  
Electronic Expansion Control Valve  
REFRIGERANT PIPING  
Limit of piping length  
ft.  
ft.  
ft.  
(m)  
(m)  
(m)  
165 (50)  
100 (30)  
Limit of piping length at shipment  
Limit of elevation difference  
between the two units  
Outdoor unit is higher than indoor unit: 165 (50)  
Outdoor unit is lower than indoor unit: 100 (30)  
Refrigerant piping  
Flare type  
Narrow pipe  
Wide pipe  
in. (mm)  
in. (mm)  
3 / 8 (9.52)  
3 / 4 (19.05)  
DIMENSIONS & WEIGHT  
Indoor unit  
9-7/16  
Outdoor unit  
48-5/8  
Unit dimensions  
Height  
Width  
Depth  
Height  
Width  
Depth  
in. (mm)  
in. (mm)  
in. (mm)  
in. (mm)  
in. (mm)  
in. (mm)  
lbs. (kg)  
lbs. (kg)  
cu.ft. (m3)  
(240)  
(1,575)  
(670)  
(317)  
(1,678)  
(789)  
(41)  
(1,235)  
(940)  
(340)  
(1326)  
(1,016)  
(416)  
(92)  
62-1/32  
26-3/8  
12-15/32  
66-1/16  
31-1/16  
90  
37-1/32  
13-3/8  
52-7/32  
40  
Indoor grille dimensions  
16-3/8  
203  
Net weight  
Shipping weight  
Shipping volume  
104  
(47)  
227  
(103)  
(0.56)  
14.8  
(0.42)  
19.8  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
Cooling :  
Rating conditions (*)  
Heating :  
Rating conditions (*)  
: Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB  
: Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB  
Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB  
SM830082  
I - 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-1 Unit Specifications  
MODEL No.  
Indoor Unit  
UH2442  
CH2442  
Outdoor Unit  
POWER SOURCE  
PERFORMANCE  
Capacity*  
230 - 208 V / 1 Phase / 60 Hz  
Cooling  
Heating  
BTU / h  
24,000  
8.4  
23,400  
7.7  
27,000  
16,200  
26,500  
15,500  
(17°F)**  
Moisture removal (High)  
Air circulation (H / M / L)  
External Static Pressure  
S.E.E.R. (H.S.P.F.)  
Pints / h  
230 V  
cu.ft. / min.  
670 / 530 / 460  
0.2 (49) : at shipment / 0.4 (100) : using jumper cable  
in.Aq (Pa)  
BTU / Wh  
10.0  
10.0  
(7.0)  
(7.0)  
ELECTRICAL RATINGS  
Voltage rating  
VAC  
VAC  
A
230  
208  
230  
208  
Available voltage range  
Running amperes  
187 - 253  
11.5  
12.1  
12.0  
12.5  
Power input*  
W
2,550  
2,480  
2,650  
2,080  
2,550  
1,960  
(17°F)**  
Maximum overcurrent protection  
FEATURES  
A
25  
Controls  
Microprocessor  
Built-in 0°F  
3 and Automatic control / 3 (Auto)  
RCS-SH80UG (72-hour ON / OFF)  
RCS-BH80UA. WL (72-hour ON / OFF)  
— / —  
1
Low ambient control  
Fan speeds Indoor / Outdoor  
Optional Wired Remote Controller (Timer)  
Optional Wireless Remote Controller (Timer)  
Air deflection  
Horizontal / Vertical  
Air filter  
Optional  
Operation sound  
Indoor - Hi / Me / Lo  
dB - A  
dB - A  
34 / 30 / 27 : at shipment / 38 / 34 / 30 : using jumper cable  
53  
Outdoor - Hi  
Refrigerant control  
Electronic Expansion Valve  
REFRIGERANT PIPING  
Limit of piping length  
ft.  
ft.  
ft.  
(m)  
(m)  
(m)  
165 (50)  
100 (30)  
Limit of piping length at shipment  
Limit of elevation difference  
between the two units  
Outdoor unit is higher than indoor unit: 165 (50)  
Outdoor unit is lower than indoor unit: 100 (30)  
Refrigerant piping  
Flare type  
Narrow pipe  
Wide pipe  
in. (mm)  
in. (mm)  
1 / 4 (6.35)  
3 / 4 (19.05)  
DIMENSIONS & WEIGHT  
Indoor unit  
12-7/32  
Outdoor unit  
28-15/16  
Unit dimensions  
Height  
Width  
Depth  
in. (mm)  
in. (mm)  
in. (mm)  
ibs. (kg)  
in. (mm)  
in. (mm)  
in. (mm)  
lbs. (kg)  
cu.ft. (m3)  
(310)  
(1,000)  
(630)  
(735)  
(940)  
(340)  
(826)  
(1,016)  
(416)  
(71)  
39-3/8  
24-13/16  
1-1/4  
37-1/32  
13-3/8  
32-17/32  
40  
Net weight  
(32)  
Package dimensions  
Height  
Width  
Depth  
14-3/32  
46-7/8  
30-13/16  
82  
(358)  
(1,191)  
(1,191)  
(37)  
16-3/8  
157  
Shipping weight  
Shipping volume  
170  
(77)  
11.8  
(0.334)  
12.3  
(0.349)  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
Cooling :  
Rating conditions (*)  
Heating :  
Rating conditions (*)  
: Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB  
: Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB  
Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB  
SM830082  
I - 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-1 Unit Specifications  
MODEL No.  
Indoor Unit  
UH3642  
CH3642  
Outdoor Unit  
POWER SOURCE  
PERFORMANCE  
Capacity*  
230 - 208 V / 1 Phase / 60 Hz  
Cooling  
Heating  
BTU / h  
34,500  
10.0  
33,000  
9.9  
37,500  
25,000  
36,500  
24,000  
(17°F)**  
Moisture removal (High)  
Air circulation (H / M / L)  
External Static Pressure  
S.E.E.R. (H.S.P.F.)  
Pints / h  
230 V  
cu.ft. / min.  
1,060 / 920 / 750  
0.24 (59) : at shipment / 0.38 (94) : using jumper cable  
in.Aq (Pa)  
BTU / Wh  
10.3  
10.5  
(7.0)  
(7.0)  
ELECTRICAL RATINGS  
Voltage rating  
VAC  
VAC  
A
230  
208  
230  
208  
Available voltage range  
Running amperes  
187 - 253  
15.1  
15.7  
18.2  
19.6  
Power input*  
W
3,350  
3,170  
3,780  
3,000  
3,760  
2,900  
(17°F)**  
Maximum overcurrent protection  
FEATURES  
A
40  
Controls  
Microprocessor  
Built-in 0°F  
Low ambient control  
Fan speeds Indoor / Outdoor  
1
3 and Automatic control / 3 (Auto)  
Optional Wired Remote Controller (Timer)  
Optional Wireless Remote Controller (Timer)  
Air deflection  
RCS-SH80UG (72-hour ON / OFF)  
RCS-SH80UA. WL / RCS-BH80UA. WL (72-hour ON / OFF)  
Horizontal / Vertical  
— / —  
Air filter  
Optional  
Operation sound  
Indoor - Hi / Me / Lo  
Outdoor - Hi  
dB - A  
dB - A  
38 / 33 / 31 : at shipment / 42 / 38 / 33 : using jumper cable  
56  
Refrigerant control  
Electronic Expansion Valve  
REFRIGERANT PIPING  
Limit of piping length  
ft.  
ft.  
ft.  
(m)  
(m)  
(m)  
165 (50)  
100 (30)  
Limit of piping length at shipment  
Limit of elevation difference  
between the two units  
Outdoor unit is higher than indoor unit: 165 (50)  
Outdoor unit is lower than indoor unit: 100 (30)  
Refrigerant piping  
Flare type  
Narrow pipe  
Wide pipe  
in. (mm)  
in. (mm)  
3 / 8 (9.52)  
3 / 4 (19.05)  
DIMENSIONS & WEIGHT  
Indoor unit  
12-7/32  
Outdoor unit  
Unit dimensions  
Height  
Width  
Depth  
Height  
Width  
Depth  
in. (mm)  
in. (mm)  
in. (mm)  
in. (mm)  
in. (mm)  
in. (mm)  
ibs. (kg)  
lbs. (kg)  
cu.ft. (m3)  
(310)  
(1,480)  
(630)  
48-5/8  
(1,235)  
(940)  
58-9/32  
24-13/16  
14-3/32  
65-25/32  
30-13/16  
104  
37-1/32  
13-3/8  
52-7/32  
40  
(340)  
Package dimensions  
(358)  
(1,326)  
(1,016)  
(416)  
(1,671)  
(783)  
16-3/8  
203  
Net weight  
(47)  
(92)  
Shipping weight  
Shipping volume  
115  
(52)  
227  
(103)  
16.5  
(0.468)  
19.8  
(0.56)  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
Cooling :  
Rating conditions (*)  
Heating :  
Rating conditions (*)  
: Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB  
: Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB  
Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB  
SM830082  
I - 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-1 Unit Specifications  
MODEL No.  
Indoor Unit  
KH2442  
CH2442  
Outdoor Unit  
POWER SOURCE  
PERFORMANCE  
Capacity*  
230 - 208 V / 1 Phase / 60 Hz  
Cooling  
Heating  
BTU / h  
22,000  
7.1  
21,000  
6.8  
25,000  
16,000  
24,300  
15,300  
(17°F)**  
Moisture removal (High)  
Air circulation (H / M / L)  
S.E.E.R. (H.S.P.F.)  
Pints / h  
cu.ft. / min.  
BTU / Wh  
230 V  
540 / 460 / 380  
10.0  
230  
10.0  
208  
(7.0)  
(7.0)  
208  
ELECTRICAL RATINGS  
Voltage rating  
VAC  
VAC  
A
230  
Available voltage range  
Running amperes  
187 - 253  
10.3  
10.9  
11.3  
12.2  
Power input*  
W
2,300  
2,220  
2,500  
2,100  
2,430  
2,070  
(17°F)**  
Maximum overcurrent protection  
FEATURES  
A
25  
Controls  
Microprocessor  
Low ambient control  
Fan speeds Indoor / Outdoor  
Built-in 0°F  
1
3 and Automatic control / 3 (Auto)  
RCS-SH80UG (72-hour ON / OFF)  
RCS-BH80UA. WL (72-hour ON / OFF)  
Manual / Automatic  
Optional Wired Remote Controller (Timer)  
Optional Wireless Remote Controller (Timer)  
Air deflection  
Horizontal / Vertical  
Air filter  
Washable, easy access  
Operation sound  
Indoor - Hi / Me / Lo  
Outdoor - Hi  
dB - A  
dB - A  
45 / 42 / 40  
53  
Refrigerant control  
Electronic Expansion Control Valve  
REFRIGERANT PIPING  
Limit of piping length  
ft.  
ft.  
ft.  
(m)  
(m)  
(m)  
165 (50)  
100 (30)  
Limit of piping length at shipment  
Limit of elevation difference  
between the two units  
Outdoor unit is higher than indoor unit: 165 (50)  
Outdoor unit is lower than indoor unit: 100 (30)  
Refrigerant piping  
Flare type  
Narrow pipe  
Wide pipe  
in. (mm)  
in. (mm)  
1 / 4 (6.35)  
3 / 4 (19.05)  
DIMENSIONS & WEIGHT  
Indoor unit  
14-9/16  
Outdoor unit  
28-15/16  
Unit dimensions  
Height  
Width  
Depth  
Height  
Width  
Depth  
in. (mm)  
in. (mm)  
in. (mm)  
in. (mm)  
in. (mm)  
in. (mm)  
lbs. (kg)  
lbs. (kg)  
cu.ft. (m3)  
(370)  
(1,250)  
(210)  
(735)  
(940)  
(340)  
(826)  
(1,016)  
(416)  
(71)  
49-7/32  
8-9/32  
18-3/16  
52-23/32  
10-11/32  
40  
37-1/32  
13-3/8  
32-17/32  
40  
Indoor grille dimensions  
(462)  
(1,339)  
(263)  
16-3/8  
157  
Net weight  
(18)  
Shipping weight  
Shipping volume  
51  
(23)  
170  
(77)  
5.8  
(0.163)  
12.3  
(0.349)  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
Cooling :  
Rating conditions (*)  
Heating :  
Rating conditions (*)  
: Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB  
: Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB  
Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB  
SM830082  
I - 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-1 Unit Specifications  
MODEL No.  
Indoor Unit  
KH3642  
CH3642  
Outdoor Unit  
POWER SOURCE  
PERFORMANCE  
Capacity*  
230 - 208 V / 1 Phase / 60 Hz  
Cooling  
Heating  
BTU / h  
33,000  
10.6  
32,000  
10.6  
40,000  
25,000  
39,000  
24,000  
(17°F)**  
Moisture removal (High)  
Air circulation (H / M / L)  
S.E.E.R. (H.S.P.F.)  
Pints / h  
cu.ft. / min.  
BTU / Wh  
230 V  
830 / 710 / 590  
10.3  
230  
10.5  
208  
(7.6)  
(7.6)  
208  
ELECTRICAL RATINGS  
Voltage rating  
VAC  
VAC  
A
230  
Available voltage range  
Running amperes  
187 - 253  
14.9  
15.5  
17.8  
19.1  
Power input*  
W
3,290  
3,120  
3,860  
3,000  
3,810  
2,900  
(17°F)**  
Maximum overcurrent protection  
FEATURES  
A
40  
Controls  
Microprocessor  
Low ambient control  
Fan speeds Indoor / Outdoor  
Built-in 0°F  
3 and Automatic control / 3 (Auto)  
RCS-SH80UG (72-hour ON / OFF)  
RCS-BH80UA. WL (72-hour ON / OFF)  
Manual / Automatic  
1
Optional Wired Remote Controller (Timer)  
Optional Wireless Remote Controller (Timer)  
Air deflection  
Horizontal / Vertical  
Air filter  
Washable, easy access  
Operation sound  
Indoor - Hi / Me / Lo  
Outdoor - Hi  
dB - A  
dB - A  
48 / 44 / 40  
56  
Refrigerant control  
Electronic Expansion Control Valve  
REFRIGERANT PIPING  
Limit of piping length  
ft.  
ft.  
ft.  
(m)  
(m)  
(m)  
165 (50)  
100 (30)  
Limit of piping length at shipment  
Limit of elevation difference  
between the two units  
Outdoor unit is higher than indoor unit: 165 (50)  
Outdoor unit is lower than indoor unit: 100 (30)  
Refrigerant piping  
Flare type  
Narrow pipe  
Wide pipe  
in. (mm)  
in. (mm)  
3 / 8 (9.52)  
3 / 4 (19.05)  
DIMENSIONS & WEIGHT  
Indoor unit  
14-9/16  
Outdoor unit  
Unit dimensions  
Height  
Width  
Depth  
Height  
Width  
Depth  
in. (mm)  
in. (mm)  
in. (mm)  
in. (mm)  
in. (mm)  
in. (mm)  
lbs. (kg)  
lbs. (kg)  
cu.ft. (m3)  
(370)  
(1,500)  
(240)  
48-5/8  
(1,235)  
(940)  
59-1/16  
9-7/16  
18-3/16  
62-9/16  
11-5/8  
73  
37-1/32  
13-3/8  
52-7/32  
40  
(340)  
Indoor grille dimensions  
(462)  
(1,326)  
(1,016)  
(416)  
(1,589)  
(295)  
16-3/8  
203  
Net weight  
(33)  
(92)  
Shipping weight  
Shipping volume  
90  
(41)  
227  
(103)  
7.7  
(0.217)  
19.8  
(0.56)  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
Cooling :  
Rating conditions (*)  
Heating :  
Rating conditions (*)  
: Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB  
: Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB  
Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB  
SM830082  
I - 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-2 Major Component Specifications  
(A) Indoor Unit  
MODEL No.  
XH2442  
Source  
230 - 208 VAC / 1 phase / 60 Hz  
RCS - SH80UA, WL  
CR - TH2442  
Remote controller (Option)  
Controller P. C. B Ass'y  
Control circuit fuse  
250 VAC, 3 A  
Fan (Number … diameter)  
Fan motor  
in.  
(mm)  
Turbo (1…17-7/16 (443))  
Model  
SFG6X - 41D6P  
Source  
230 - 208 V / 1 phase / 60 Hz  
No. of pole … r.p.m. (230 V, High)  
Nominal output  
rpm  
W
6 … 464  
40  
Coil resistance  
BRW - WHT  
WHT - VLT  
VLT - ORG  
:
:
:
170.3  
18.1  
43.2  
,
,
,
ORG - YEL  
WHT - PNK  
YEL - BLK  
:
:
:
43.2  
83.5  
60.2  
(Ambient temperature 68 °F)  
Safety device  
1
Operating temperature  
Open  
Close  
VAC,  
°F  
°F  
µF  
266 ± 14.4  
174.2 ± 27  
440 V , 4.5 µF  
Run capacitor  
Electronic expansion valve  
Coil  
DKV - MOZS726E  
Coil resistance (at 20°C)  
ORG - GRY  
RED - GRY  
:
:
46  
46  
,
,
YEL - GRY  
BLK - GRY  
:
:
46  
46  
Valve body  
IKV - 24D18  
Heat exchanger  
Coil  
Aluminum plate fin / Copper tube  
2 … 14.9  
Rows … Fins per inch  
Face area  
ft.2  
(m2)  
3.69 (0.343)  
Panel  
Model No.  
PNR - XH2442  
MT8 - 3C  
Auto louver motor  
Auto louver motor … Rated  
Coil resistance (Ambient temperature 77 °F)  
V, W, rpm  
240 VAC , 3 W , 3 rpm  
16.430 Ω ± 8 %  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
SM830082  
I - 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-2 Major Component Specifications  
(A) Indoor Unit  
MODEL No.  
XH3642  
Source  
230 - 208 VAC / 1 phase / 60 Hz  
RCS - SH80UA, WL  
CR - TH2442  
Remote controller (Option)  
Controller P. C. B Ass'y  
Control circuit fuse  
250 VAC, 3 A  
Fan (Number … diameter)  
Fan motor  
in.  
(mm)  
Turbo (1…17-7/16 (443))  
Model  
SFG6X - 81A6P  
Source  
230 - 208 V / 1 phase / 60 Hz  
No. of pole … r.p.m. (230 V, High)  
Nominal output  
rpm  
W
6 … 467  
60  
Coil resistance  
BRW - WHT  
WHT - VLT  
VLT - ORG  
:
:
:
75.1  
6.7  
,
,
,
ORG - YEL  
VLT - PNK  
YEL - BLK  
:
:
:
27.4  
42.7  
58.0  
(Ambient temperature 68 °F)  
20.6  
Safety device  
1
Operating temperature  
Open  
Close  
VAC,  
°F  
°F  
266 ± 14.4  
174.2 ± 27  
440 V , 5 µF  
Run capacitor  
Electronic expansion valve  
Coil  
µF  
EKV - MOZS742E  
Coil resistance (at 20°C)  
ORG - GRY  
RED - GRY  
:
:
46  
46  
,
,
YEL - GRY  
BLK - GRY  
:
:
46  
46  
Valve body  
HKV - 30D27  
Heat exchanger  
Coil  
Aluminum plate fin / Copper tube  
2 … 14.9  
Rows … Fins per inch  
Face area  
ft.2  
(m2)  
8.20 (0.762)  
Panel  
Model No.  
PNR - XH3642  
MT8 - 3C  
Auto louver motor  
Auto louver motor … Rated  
Coil resistance (Ambient temperature 77 °F)  
V, W, rpm  
240 VAC , 3 W , 3 rpm  
16.430 Ω ± 8 %  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
SM830082  
I - 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-2 Major Component Specifications  
(A) Indoor Unit  
MODEL No.  
XH4242  
Source  
230 - 208 VAC / 1 phase / 60 Hz  
RCS - SH80UA, WL  
CR - TH2442  
Remote controller (Option)  
Controller P. C. B Ass'y  
Control circuit fuse  
250 VAC, 3 A  
Fan (Number … diameter)  
Fan motor  
in.  
(mm)  
Turbo (1…17-7/16 (443))  
Model  
SFG6X - 81A6P  
Source  
230 - 208 V / 1 phase / 60 Hz  
No. of pole … r.p.m. (230 V, High)  
Nominal output  
rpm  
W
6 … 506  
60  
Coil resistance  
BRW - WHT  
WHT - VLT  
VLT - ORG  
:
:
:
75.1  
6.7  
,
,
,
ORG - YEL  
VLT - PNK  
YEL - BLK  
:
:
:
27.4  
42.7  
58.0  
(Ambient temperature 68 °F)  
20.6  
Safety device  
1
Operating temperature  
Open  
Close  
VAC,  
°F  
°F  
µF  
266 ± 14.4  
174.2 ± 27  
440 V , 6 µF  
Run capacitor  
Electronic expansion valve  
Coil  
EKV - MOZS742E  
Coil resistance (at 20°C)  
ORG - GRY  
RED - GRY  
:
:
46  
46  
,
,
YEL - GRY  
BLK - GRY  
:
:
46  
46  
Valve body  
HKV - 30D27  
Heat exchanger  
Coil  
Aluminum plate fin / Copper tube  
2 … 14.9  
Rows … Fins per inch  
Face area  
ft.2  
(m2)  
8.20 (0.762)  
Panel  
Model No.  
PNR - XH3642  
MT8 - 3C  
Auto louver motor  
Auto louver motor … Rated  
Coil resistance (Ambient temperature 77 °F)  
V, W, rpm  
240 VAC , 3 W , 3 rpm  
16.430 Ω ± 8 %  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
SM830082  
I - 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-2 Major Component Specifications  
(A) Indoor Unit  
MODEL No.  
TH2442  
Source  
230 - 208 V / 1 phase / 60 Hz  
RCS - SH80UA, WL  
CR - TH2442  
Remote controller (Option)  
Controller P. C. B Ass'y  
Control circuit fuse  
250 V, 3 A  
Fan (Number … diameter)  
Fan motor  
in.  
(mm)  
Centrifugal (4 ... 5-1/8(130))  
Model  
SR4X - 51A6P  
Source  
230 - 208 V / 1 phase / 60 Hz  
No. of pole … r.p.m. (230 V, High)  
Nominal output  
rpm  
W
1,179  
31  
Coil resistance  
BRW - WHT  
WHT - VLT  
VLT - ORG  
:
:
:
111.0  
35.4  
13.4  
,
,
,
ORG - YEL  
BLK - PNK  
YEL - BLK  
:
:
16.7  
23.9  
(Ambient temperature 68 °F)  
: 136.6  
Safety device  
1
Operating temperature  
Open  
Close  
VAC,  
°F  
°F  
266 ± 14.4  
174.2 ± 27  
440 V , 1.5 µF  
Run capacitor  
µF  
Electronic refrigerant control valve  
Solenoid control model  
Coil resistance  
DKV - MOZS582E0  
ORG - GRY  
RED - GRY  
:
:
46  
46  
,
,
YEL - GRY  
BLK - GRY  
:
:
46  
46  
(Ambient temperature 68 °F)  
Solenoid control valve model  
Heat exchanger  
IKV - 24D18  
Coil  
Aluminum plate fin / Copper tube  
3 … 14.9  
Rows … Fins per inch  
Face area  
ft.2  
(m2)  
1.81 (0.168)  
Auto louver motor  
Model No.  
MT8 - 3C  
Auto louver motor … Rated  
Coil resistance (Ambient temperature 77 °F)  
V, W, rpm  
240 VAC , 3 W , 3 rpm  
16,430 Ω ± 8 %  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
SM830082  
I - 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-2 Major Component Specifications  
(A) Indoor Unit  
MODEL No.  
TH3642  
Source  
230 - 208 V / 1 phase / 60 Hz  
RCS - SH80UA, WL  
CR - TH2442  
Remote controller (Option)  
Controller P. C. B Ass'y  
Control circuit fuse  
250 V, 3 A  
Fan (Number … diameter)  
Fan motor  
in.  
(mm)  
Centrifugal (4 ... 5-29/32(150))  
Model  
KFG4X - 101C6P  
230 - 208 V / 1 phase / 60 Hz  
4 ... 1,040  
Source  
No. of pole … r.p.m. (230 V, High)  
Nominal output  
rpm  
W
100  
Coil resistance  
BRW - WHT  
WHT - VLT  
VLT - ORG  
:
:
:
61.05  
,
ORG - YEL  
:
:
:
13.23  
19.25  
10.81  
(Ambient temperature 68 °F)  
9.955 , YEL - BLK  
9.576 , BLK - PNK  
Safety device  
1
Operating temperature  
Open  
Close  
VAC,  
°F  
°F  
µF  
266 ± 14.4  
174.2 ± 27  
440 V , 4 µF  
Run capacitor  
Electronic expansion valve  
Coil  
EKV - MOZS584E0  
Coil resistance  
ORG - GRY  
RED - GRY  
:
:
46  
46  
,
,
YEL - GRY  
BLK - GRY  
:
:
46  
46  
(Ambient temperature 68 °F)  
Valve body  
HKV - 30D24  
Heat exchanger  
Coil  
Aluminum plate fin / Copper tube  
3 … 14.9  
Rows … Fins per inch  
Face area  
ft.2  
(m2)  
3.51 (0.326)  
Auto louver motor  
Model No.  
MT8 - 3C  
Auto louver motor … Rated  
Coil resistance (Ambient temperature 77 °F)  
V, W, rpm  
240 VAC , 3 W , 3 rpm  
16,430 Ω ± 8 %  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
SM830082  
I - 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-2 Major Component Specifications  
(A) Indoor Unit  
MODEL No.  
TH4242  
Source  
230 - 208 V / 1 phase / 60 Hz  
RCS - SH80UA, WL  
CR - TH2442  
Remote controller (Option)  
Controller P. C. B Ass'y  
Control circuit fuse  
250 V, 3 A  
Fan (Number … diameter)  
Fan motor  
in.  
(mm)  
Centrifugal (4 ... 5-29/32(150))  
Model  
KFG4X - 101C6P  
230 - 208 V / 1 phase / 60 Hz  
4 ... 1,099  
Source  
No. of pole … r.p.m. (230 V, High)  
Nominal output  
rpm  
W
100  
Coil resistance  
BRW - WHT  
WHT - VLT  
VLT - ORG  
:
:
:
61.05  
,
ORG - YEL  
:
:
:
13.23  
19.25  
10.81  
(Ambient temperature 68 °F)  
9.955 , YEL - BLK  
9.576 , BLK - PNK  
Safety device  
1
Operating temperature  
Open  
Close  
VAC,  
°F  
°F  
266 ± 14.4  
174.2 ± 27  
440 V , 5 µF  
Run capacitor  
Electronic expansion valve  
Coil  
µF  
EKV - MOZS584E0  
Coil resistance  
ORG - GRY  
RED - GRY  
:
:
46  
46  
,
,
YEL - GRY  
BLK - GRY  
:
:
46  
46  
(Ambient temperature 68 °F)  
Valve body  
HKV - 30D27  
Heat exchanger  
Coil  
Aluminum plate fin / Copper tube  
3 … 14.9  
Rows … Fins per inch  
Face area  
ft.2  
(m2)  
3.51 (0.326)  
Auto louver motor  
Model No.  
MT8 - 3C  
Auto louver motor … Rated  
Coil resistance (Ambient temperature 77 °F)  
V, W, rpm  
240 VAC , 3 W , 3 rpm  
16,430 Ω ± 8 %  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
SM830082  
I - 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-2 Major Component Specifications  
(A) Indoor Unit  
MODEL No.  
UH2442  
Source  
230 - 208 V / 1 phase / 60 Hz  
RCS - BH80UA, WL  
CR - TH2442  
Remote controller (Option)  
Controller P. C. B Ass'y  
Control circuit fuse  
250 V, 3 A  
Fan (Number … diameter)  
Fan motor  
in.  
(mm)  
Centrifugal (4 ... 5-29/32(150))  
Model  
KFG4X - 71B6P  
Source  
230 - 208 V / 1 phase / 60 Hz  
No. of pole … r.p.m. (230 V, High)  
Nominal output  
rpm  
W
4 ... 920  
100  
Coil resistance  
BRW - WHT  
WHT - VLT  
VLT - ORG  
:
:
:
74.7  
19.1  
10.5  
,
,
,
ORG - YEL  
YEL - BLK  
BLK - PNK  
:
:
:
9.59  
10.52  
21.72  
(Ambient temperature 68 °F)  
Safety device  
1
Operating temperature  
Open  
Close  
VAC,  
°F  
°F  
µF  
266 ± 14.4  
174.2 ± 27  
440 V , 5 µF  
Run capacitor  
Electronic expansion valve  
Coil  
DKV - MOZS697E0  
Coil resistance  
(Ambient temperature 68 °F)  
Valve body  
ORG - GRY  
RED - GRY  
:
:
46  
46  
,
,
YEL - GRY  
BLK - GRY  
:
:
46  
46  
IKV - 24D12  
Heat exchanger  
Coil  
Aluminum plate fin / Copper tube  
3 … 14.9  
Rows … Fins per inch  
Face area  
ft.2  
(m2)  
2.03 (0.189)  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
SM830082  
I - 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-2 Major Component Specifications  
(A) Indoor Unit  
MODEL No.  
UH3642  
Source  
230 - 208 V / 1 phase / 60 Hz  
RCS - BH80UA, WL  
CR - TH2442  
Remote controller (Option)  
Controller P. C. B Ass'y  
Control circuit fuse  
250 V, 3 A  
Fan (Number … diameter)  
Fan motor  
in.  
(mm)  
Centrifugal (4 ... 5-29/32(150))  
Model  
KFG4X - 141A6P  
Source  
230 - 208 V / 1 phase / 60 Hz  
No. of pole … r.p.m. (230 V, High)  
Nominal output  
rpm  
W
4 ... 940  
100  
Coil resistance  
BRW - WHT  
WHT - VLT  
VLT - ORG  
:
:
:
39.9  
6.91  
11.4  
,
,
,
ORG - YEL  
YEL - BLK  
BLK - PNK  
:
:
:
9.37  
8.86  
(Ambient temperature 68 °F)  
14.3  
Safety device  
1
Operating temperature  
Open  
Close  
VAC,  
°F  
°F  
266 ± 14.4  
174.2 ± 27  
440 V , 5 µF  
Run capacitor  
Electronic expansion valve  
Coil  
µF  
DKV - MOZS698E0  
Coil resistance  
(Ambient temperature 68 °F)  
Valve body  
ORG - GRY  
RED - GRY  
:
:
46  
46  
,
,
YEL - GRY  
BLK - GRY  
:
:
46  
46  
HKV - 30D27  
Heat exchanger  
Coil  
Aluminum plate fin / Copper tube  
3 … 12.7  
Rows … Fins per inch  
Face area  
ft.2  
(m2)  
3.32 (0.308)  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
SM830082  
I - 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-2 Major Component Specifications  
(A) Indoor Unit  
MODEL No.  
KH2442  
Source  
230 - 208 V / 1 phase / 60 Hz  
RCS - BH80UA, WL  
CR - TH2442  
Remote controller (Option)  
Controller P. C. B Ass'y  
Control circuit fuse  
Fan  
250 V, 3 A  
Cross-flow  
Number ... Dia. and length  
Fan motor  
in.  
(mm)  
1 ... O.D. 4-1/3 (110), L39 (990)  
Model  
UF4Q - 31A6P  
Source  
230 - 208 V / 1 phase / 60 Hz  
No. of pole … r.p.m. (230 V, High)  
Nominal output  
rpm  
W
4 ... 1,276  
30  
Coil resistance  
BRW - WHT  
WHT - VLT  
VLT - ORG  
:
:
:
197.2  
41.4  
22.2  
,
,
,
ORG - YEL  
YEL - PNK  
:
:
59.1  
48.8  
(Ambient temperature 68 °F)  
1
Safety device  
Operating temperature  
Open  
Close  
VAC,  
°F  
°F  
µF  
248  
±
9
171 ± 27  
Run capacitor  
Electronic refrigerant control valve  
Solenoid control model  
Coil resistance  
440 V , 1.8 µF  
DKV - MOZS582E0  
ORG - GRY  
RED - GRY  
:
:
46  
46  
,
,
YEL - GRY  
BLK - GRY  
:
:
46  
46  
(Ambient temperature 68 °F)  
Solenoid control valve model  
Heat exchanger  
Coil  
IKV - 24D11  
Aluminum plate fin / Copper tube  
3 … 12.7  
Rows …  
Face area  
ft.2  
(m2)  
2.57 (0.24)  
Louver Motor  
Model  
M2EA24ZA01  
208 to 230 V, 60 Hz  
8 … 3  
Rating  
No. of pole … rpm  
Output  
W
2.5  
Coil resistance (Ambient temperature 68 °F)  
kΩ  
16.45 ± 8 %  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
SM830082  
I - 20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-2 Major Component Specifications  
(A) Indoor Unit  
MODEL No.  
KH3642  
Source  
230 - 208 V / 1 phase / 60 Hz  
RCS - BH80UA, WL  
CR - TH2442  
Remote controller (Option)  
Controller P. C. B Ass'y  
Control circuit fuse  
Switch Ass'y  
250 V, 3 A  
SW - KHS2432  
Fan  
Cross-flow  
Number ... Dia. and length  
Fan motor  
in.  
(mm)  
1 ... O.D. 4-13/18 (120), L46 (1,170)  
Model  
SFG4Q - 41B6P  
230 - 208 V / 1 phase / 60 Hz  
4 ... 1,273  
Source  
No. of pole … r.p.m. (230 V, High)  
Nominal output  
rpm  
W
50  
Coil resistance  
GRY - WHT  
WHT - VLT  
VLT - ORG  
:
:
:
122.3  
15.98  
11.93  
,
,
,
ORG - YEL  
YEL - PNK  
:
:
23.03  
9.272  
(Ambient temperature 68 °F)  
1
Safety device  
Operating temperature  
Open  
Close  
VAC,  
°F  
°F  
266 ± 14.4  
174.2 ± 26  
440 V , 4 µF  
Run capacitor  
µF  
Electronic expansion valve  
Coil  
EKV - MOZS557E0  
Coil resistance  
ORG - GRY  
RED - GRY  
:
:
46  
46  
,
,
YEL - GRY  
BLK - GRY  
:
:
46  
46  
(Ambient temperature 68 °F)  
Valve body  
HKV - 30D26  
Heat exchanger  
Coil  
Aluminum plate fin / Copper tube  
3 … 12.7  
Rows … Fins per inch  
Face area  
ft.2  
(m2)  
3.23 (0.3)  
Louver Motor  
Model  
M2EA24ZA01  
208 to 230 V, 60 Hz  
8 … 3  
Rating  
No. of pole … rpm  
Output  
W
2.5  
Coil resistance (Ambient temperature 68 °F)  
kΩ  
16.45 ± 8 %  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
SM830082  
I - 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-2 Major Component Specifications  
(B) Outdoor Unit  
MODEL No.  
CH2442  
Source  
230 - 208 VAC / 1 phase / 60 Hz  
CR - CH2442 (Microprocessor)  
250 VAC, 3 A  
Controller P.C.B. Ass'y  
Control circuit fuse  
Compressor  
Rotary (Hermetic)  
C - 2R160H6T  
Model  
Source  
230 - 208 VAC / 1 phase / 60 Hz  
1,700  
Nominal output  
W
cc  
Compressor oil  
800  
Coil resistance (Ambient temperature 77 °F)  
Safety device  
C – R : 0.885 , C – S : 1.773  
Internal type  
Overload relay models  
Operating temperature  
Open  
Close  
°F  
°F  
297 ±  
9
198 ± 20  
Operating ampere (at 77 °F)  
Run capacitor  
A
1
VAC,  
VAC,  
lbs.  
µF  
W
400 VAC, 40 µF  
230 VAC, 30 W  
R22 : 6.17 (2.8)  
Crank case heater  
Refrigerant amount charged at shipment  
High pressure switch  
Set pressure  
(kg)  
-
ACB 1UB11  
+
28.44  
7.11  
+ 2.0  
+ 0.5  
OFF lb/in2 (kg/cm2)  
ON lb/in2 (kg/cm2)  
426.6  
(30  
)
+
341.3 ± 28.44 (24 ± 2.0)  
Propeller  
Fan  
Number...diameter  
Fan speeds  
Fan motor  
in.  
(mm)  
1 ... 18 - 3/32 (460)  
2 (AUTO)  
Model  
KFC6T - 91D6P  
Source  
230 - 208 VAC / 1 phase / 60 Hz  
No. of pole ..... rpm (230 V, High)  
Nominal output  
6 ... 879  
110  
W
Coil resistance  
(Ambient temperature 68 °F)  
BRN – WHT  
WHT – VLT  
:
:
67.14 , VLT – YEL : 11.42  
64.85 , YEL – PNK : 10.60  
Safety device  
Internal type  
Operating temperature  
Open  
Close  
VAC,  
°F  
°F  
248 ±  
9
171 ± 27  
Run capacitor  
Heat exchange  
Coil  
µF  
440 VAC, 4 µF  
Aluminum plate fin / Copper tube  
Rows ..... Fins per inch  
Face area  
2 ... 14.1  
ft.2  
(m2)  
6.78 (0.63)  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
SM830082  
I - 22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-2 Major Component Specifications  
(B) Outdoor Unit  
MODEL No.  
CH3642  
Source  
230 - 208 VAC / 1 phase / 60 Hz  
CR - CH2442 (Microprocessor)  
250 V, 3 A  
Controller P.C.B. Ass'y  
Control circuit fuse  
Compressor  
Rotary (Hermetic)  
C - R221H6R  
Model  
Source  
230 - 208 VAC / 1 phase / 60 Hz  
2,200  
Nominal output  
W
cc  
Compressor oil  
1,500  
Coil resistance (Ambient temperature 77 °F)  
Safety device  
C – R : 0.549 , C – S : 1.525  
Internal type  
Overload relay models  
Operating temperature  
Open  
Close  
°F  
°F  
320 ±  
9
189 ± 20  
Operating ampere (at 77 °F)  
Run capacitor  
A
1
VAC,  
VAC,  
lbs.  
µF  
W
400 VAC, 40 µF  
230 VAC, 30 W  
R22 : 8.82 (4.0)  
Crank case heater  
Refrigerant amount charged at shipment  
High pressure switch  
Set pressure  
(kg)  
-
ACB 1UB11  
+
28.44  
7.11  
+ 2.0  
+ 0.5  
OFF lb/in2 (kg/cm2)  
ON lb/in2 (kg/cm2)  
426.6  
(30  
)
+
341.3 ± 28.44 (24 ± 2.0)  
Propeller  
Fan  
Number...diameter  
Fan speeds  
Fan motor  
in.  
(mm)  
2 ... 18 - 3/32 (460)  
2 (AUTO)  
Model  
KFC6T - 91D6P × 2  
230 - 208 V / 1 phase / 60 Hz  
6 ... 879  
Source  
No. of pole ..... rpm (230 V, High)  
Nominal output  
W
110 × 2  
Coil resistance  
(Ambient temperature 68 °F)  
BRN – WHT  
WHT – VLT  
:
:
67.14 , VLT – YEL : 11.42  
64.85 , YEL – PNK : 10.60  
Safety device  
Internal type  
Operating temperature  
Open  
Close  
VAC,  
°F  
°F  
248 ±  
9
171 ± 27  
Run capacitor  
Heat exchange  
Coil  
µF  
440 VAC, 4 µF × 2  
Aluminum plate fin / Copper tube  
Rows ..... Fins per inch  
Face area  
2 ... 14.1  
ft.2  
(m2)  
11.63 (1.08)  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
SM830082  
I - 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-2 Major Component Specifications  
(B) Outdoor Unit  
MODEL No.  
CH4242  
Source  
230 - 208 V / 1 phase / 60 Hz  
Scroll (Hermetic)  
ZR47KC - PFV  
230 - 208 V / 1 phase / 60 Hz  
4,270  
Compressor  
Model  
Source  
Nominal output  
W
cc  
Compressor oil  
1,240  
Coil resistance (Ambient temperature 77 °F)  
Safety device  
R - W : 0.475 , S - W : 1.850  
Internal type  
Overload relay models  
Operating temperature  
Open  
Close  
°F  
°F  
320 ±  
9
189 ± 20  
Operating ampere (at 77 °F)  
Run capacitor  
A
VAC,  
lbs.  
µF  
(kg)  
400 V, 50 µF  
R22 : 9.7 (4.4)  
Refrigerant amount charged at shipment  
High pressure switch  
1
ACB - 1UB11  
+ 2.0  
Set pressure  
OFF kg/cm2  
ON kg/cm2  
30  
+ 0.5  
24 ± 2.0  
Propeller  
Fan  
Number...diameter  
Fan speeds  
Fan motor  
in.  
(mm)  
1 … 18-3/32 (460)  
2 (AUTO)  
Model  
KFC6T - 91D6P × 2  
230 - 208 V / 1 phase / 60 Hz  
6 … 879  
Source  
No. of pole … rpm (230 V, High)  
Nominal output  
rpm  
W
110 × 2  
Coil resistance  
BRW – WHT  
WHT – VLT  
:
:
67.14  
64.85  
,
,
VLT – YEL  
YEL – PNK  
:
:
11.42  
10.60  
(Ambient temperature 68 °F)  
Safety device  
Operating temperature  
Open  
Close  
VAC,  
°F  
°F  
248 ±  
9
171 ± 27  
Run capacitor  
Heat exchanger  
Coil  
µF  
440 V, 4 µF × 2  
Aluminum plate fin / Copper tube  
2 … 12.7  
Rows … Fins per inch  
Face area  
ft.2  
(m2)  
11.63 (1.08)  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
SM830082  
I - 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-3 Other Component Specifications  
(A) Indoor Unit  
MODEL No.  
XH2442  
Power Transformer  
ATR – II224A  
220 VAC, 60 Hz  
Rated  
Primary  
Secondary  
Capacity  
BRN - BRN : 14 V, 0.45 A, RED - RED : 14 V, 0.3 A  
Coil resistance  
(Ambient temprature 77 °F)  
WHT - WHT  
BRN - BRN  
:
:
61.0  
0.97  
,
,
RED - RED  
ORG - ORG  
:
:
1.37  
3.16  
Thermistor cut off temperature  
Thermistor (Coil sensor) : TH2, 3  
Coil resistance  
°F  
277  
PBC - 41E - S14  
kΩ  
14 °F : 23.7  
23 °F : 18.8  
32 °F : 15.0  
,
,
,
41 °F : 12.1  
50 °F : 9.7  
59 °F : 8.0  
Thermistor (Room sensor) : TH1  
KTEC - 35 - S6  
Coil resistance  
kΩ  
32 °F : 16.5  
41 °F : 12.8  
50 °F : 10.0  
68 °F : 6.3  
86 °F : 4.0  
,
,
,
,
,
104 °F : 2.7  
113 °F : 2.2  
122 °F : 1.8  
131 °F : 1.5  
1
Drain pump  
PJV - 1428AU  
Rated  
230 / 208 VAC, 12.5 W  
FS - 0218 - 102  
Float switch  
MAX Rated (Contact rated)  
Solenoid control valve or coil  
Solenoid control valve  
Solenoid coil  
50 W, DC 5V, 0.1 mA  
IKV - 24D18  
DKV - MOZS726E  
MT8 - 3C  
Synchronized Motor  
SM830082  
I - 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-3 Other Component Specifications  
(A) Indoor Unit  
MODEL No.  
XH3642  
Power Transformer  
ATR – IIK224A  
220 VAC, 60 Hz  
Rated  
Primary  
Secondary  
Capacity  
BRN - BRN : 14 V, 0.45 A, RED - RED : 14 V, 0.3 A  
Coil resistance  
(Ambient temprature 77 °F)  
WHT - WHT  
BRN - BRN  
:
:
61.0  
0.97  
,
,
RED - RED  
ORG - ORG  
:
:
1.37  
3.16  
Thermistor cut off temperature  
Thermistor (Coil sensor) : TH2, 3  
Coil resistance  
°F  
277  
PBC - 41E - S14  
kΩ  
14 °F : 23.7  
23 °F : 18.8  
32 °F : 15.0  
,
,
,
41 °F : 12.1  
50 °F : 9.7  
59 °F : 8.0  
Thermistor (Room sensor) : TH1  
KTEC - 35 - S6  
Coil resistance  
kΩ  
32 °F : 16.5  
41 °F : 12.8  
50 °F : 10.0  
68 °F : 6.3  
86 °F : 4.0  
,
,
,
,
,
104 °F : 2.7  
113 °F : 2.2  
122 °F : 1.8  
131 °F : 1.5  
1
Drain pump  
PJV - 1428AU  
Rated  
230 / 208 VAC, 12.5 W  
FS - 0218 - 102  
Float switch  
MAX Rated (Contact rated)  
Solenoid control valve or coil  
Solenoid control valve  
Solenoid coil  
50 W, DC 5V, 0.1 mA  
HKV - 30D27  
EKV - MOZS742E  
MT8 - 3C  
Synchronized Motor  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
SM830082  
I - 26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-3 Other Component Specifications  
(A) Indoor Unit  
MODEL No.  
XH4242  
Power Transformer  
ATR – IIK224A  
220 VAC, 60 Hz  
Rated  
Primary  
Secondary  
Capacity  
BRN - BRN : 14 V, 0.45 A, RED - RED : 14 V, 0.3 A  
Coil resistance  
(Ambient temprature 77 °F)  
WHT - WHT  
BRN - BRN  
:
:
61.0  
0.97  
,
,
RED - RED  
ORG - ORG  
:
:
1.37  
3.16  
Thermistor cut off temperature  
Thermistor (Coil sensor) : TH2, 3  
Coil resistance  
°F  
277  
PBC - 41E - S14  
kΩ  
14 °F : 23.7  
23 °F : 18.8  
32 °F : 15.0  
,
,
,
41 °F : 12.1  
50 °F : 9.7  
59 °F : 8.0  
Thermistor (Room sensor) : TH1  
KTEC - 35 - S6  
Coil resistance  
kΩ  
32 °F : 16.5  
41 °F : 12.8  
50 °F : 10.0  
68 °F : 6.3  
86 °F : 4.0  
,
,
,
,
,
104 °F : 2.7  
113 °F : 2.2  
122 °F : 1.8  
131 °F : 1.5  
1
Drain pump  
PJV - 1428AU  
Rated  
230 / 208 VAC, 12.5 W  
FS - 0218 - 102  
Float switch  
MAX Rated (Contact rated)  
Solenoid control valve or coil  
Solenoid control valve  
Solenoid coil  
50 W, DC 5V, 0.1 mA  
HKV - 30D27  
EKV - MOZS742E  
MT8 - 3C  
Synchronized Motor  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
SM830082  
I - 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-3 Other Component Specifications  
(A) Indoor Unit  
MODEL No.  
TH2442  
Power Transformer  
ATR – IIK244B  
AC 220 V, 60 Hz  
Rated  
Primary  
Secondary  
Capacity  
BRN - BRN : 14 V / 0.55 A, RED - RED : 14 V / 0.3 A  
Coil resistance  
(Ambient temprature 77 °F)  
WHT - WHT  
BRN - BRN  
:
:
48.0  
0.45  
,
,
RED - RED  
ORG - ORG  
:
:
0.89  
2.05  
Thermistor cut off temperature  
Thermistor (Coil sensor)  
Coil resistance  
°F  
277  
PBC - 41E - S14  
kΩ  
14 °F : 23.7  
23 °F : 18.8  
32 °F : 15.0  
41 °F : 12.1  
50 °F : 9.7  
,
,
,
,
,
59 °F : 8.0  
68 °F : 6.5  
86 °F : 4.4  
104 °F : 3.1  
113 °F : 2.6  
Thermistor (Room or coil sensor)  
PBC - 41E - S14  
Coil resistance  
kΩ  
32 °F : 16.5  
41 °F : 12.8  
50 °F : 10.0  
68 °F : 6.3  
86 °F : 4.0  
,
,
,
,
,
104 °F : 2.7  
113 °F : 2.2  
122 °F : 1.8  
131 °F : 1.5  
1
Electronic expansion valve  
Valve body  
IKV - 24D18  
EKV - MOZS582E0  
MT8 - 3C  
Coil  
Synchronized Motor  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
SM830082  
I - 28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-3 Other Component Specifications  
(A) Indoor Unit  
MODEL No.  
TH3642  
Power Transformer  
ATR – IIK244B  
AC 220 V, 60 Hz  
Rated  
Primary  
Secondary  
Capacity  
BRN - BRN : 14 V / 0.55 A, RED - RED : 14 V / 0.55 A  
Coil resistance  
(Ambient temprature 77 °F)  
WHT - WHT  
BRN - BRN  
:
:
48.0  
0.45  
,
,
RED - RED  
ORG - ORG  
:
:
0.89  
2.05  
Thermistor cut off temperature  
Thermistor (Coil sensor)  
Coil resistance  
°F  
277  
PBC - 41E - S14  
kΩ  
14 °F : 23.7  
23 °F : 18.8  
32 °F : 15.0  
41 °F : 12.1  
50 °F : 9.7  
,
,
,
,
,
59 °F : 8.0  
68 °F : 6.5  
86 °F : 4.4  
104 °F : 3.1  
113 °F : 2.6  
Thermistor (Room or coil sensor)  
PBC - 41E - S42  
Coil resistance  
kΩ  
32 °F : 16.5  
41 °F : 12.8  
50 °F : 10.0  
68 °F : 6.3  
86 °F : 4.0  
,
,
,
,
,
104 °F : 2.7  
113 °F : 2.2  
122 °F : 1.8  
131 °F : 1.5  
1
Electronic expansion valve  
Valve body  
HKV - 30D24  
EKV - MOZS584E0  
MT8 - 3C  
Coil  
Synchronized Motor  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
SM830082  
I - 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-3 Other Component Specifications  
(A) Indoor Unit  
MODEL No.  
TH4242  
Power Transformer  
ATR – IIK244B  
AC 220 V, 60 Hz  
Rated  
Primary  
Secondary  
Capacity  
BRN - BRN : 14 V / 0.55 A, RED - RED : 14 V / 0.3 A  
Coil resistance  
(Ambient temprature 77 °F)  
WHT - WHT  
BRN - BRN  
:
:
48.0  
0.45  
,
,
RED - RED  
ORG - ORG  
:
:
0.89  
2.05  
Thermistor cut off temperature  
Thermistor (Coil sensor)  
Coil resistance  
°F  
277  
PBC - 41E - S14  
kΩ  
14 °F : 23.7  
23 °F : 18.8  
32 °F : 15.0  
41 °F : 12.1  
50 °F : 9.7  
,
,
,
,
,
59 °F : 8.0  
68 °F : 6.5  
86 °F : 4.4  
104 °F : 3.1  
113 °F : 2.6  
Thermistor (Room or coil sensor)  
KTEC - 35 - S6  
Coil resistance  
kΩ  
32 °F : 16.5  
41 °F : 12.8  
50 °F : 10.0  
68 °F : 6.3  
86 °F : 4.0  
,
,
,
,
,
104 °F : 2.7  
113 °F : 2.2  
122 °F : 1.8  
131 °F : 1.5  
1
Electronic expansion valve  
Valve body  
HKV - 30D27  
EKV - MOZS584E0  
MT8 - 3C  
Coil  
Synchronized Motor  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
SM830082  
I - 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-3 Other Component Specifications  
(A) Indoor Unit  
MODEL No.  
UH2442  
Power Transformer  
ATR – IIK244B  
AC 220 V, 60 Hz  
Rated  
Primary  
Secondary  
Capacity  
BRN - BRN : 14 V / 0.55 A, RED - RED : 14 V / 0.3 A  
Coil resistance  
(Ambient temprature 77 °F)  
WHT - WHT  
BRN - BRN  
:
:
48.0  
0.45  
,
,
RED - RED  
ORG - ORG  
:
:
0.89  
2.05  
Thermistor cut off temperature  
Thermistor (Coil sensor)  
Coil resistance  
°F  
277  
PBC - 41E - S36  
kΩ  
14 °F : 23.7  
23 °F : 18.8  
32 °F : 15.0  
41 °F : 12.1  
50 °F : 9.7  
,
,
,
,
,
59 °F : 8.0  
68 °F : 6.5  
86 °F : 4.4  
104 °F : 3.1  
113 °F : 2.6  
Thermistor (Room or coil sensor)  
KTEC - 35 - S42  
Coil resistance  
kΩ  
32 °F : 16.5  
41 °F : 12.8  
50 °F : 10.0  
68 °F : 6.3  
86 °F : 4.0  
,
,
,
,
,
104 °F : 2.7  
113 °F : 2.2  
122 °F : 1.8  
131 °F : 1.5  
1
Electronic expansion valve  
Valve body  
Coil  
HKV - 30D16  
EKV - MOZS559E0  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
SM830082  
I - 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-3 Other Component Specifications  
(A) Indoor Unit  
MODEL No.  
UH3642  
Power Transformer  
ATR – IIK244B  
AC 220 V, 60 Hz  
Rated  
Primary  
Secondary  
Capacity  
BRN - BRN : 14 V / 0.55 A, RED - RED : 14 V / 0.3 A  
Coil resistance  
(Ambient temprature 77 °F)  
WHT - WHT  
BRN - BRN  
:
:
48.0  
0.45  
,
,
RED - RED  
ORG - ORG  
:
:
0.89  
2.05  
Thermistor cut off temperature  
Thermistor (Coil sensor)  
Coil resistance  
°F  
277  
PBC - 41E - S36  
kΩ  
14 °F : 23.7  
23 °F : 18.8  
32 °F : 15.0  
41 °F : 12.1  
50 °F : 9.7  
,
,
,
,
,
59 °F : 8.0  
68 °F : 6.5  
86 °F : 4.4  
104 °F : 3.1  
113 °F : 2.6  
Thermistor (Room or coil sensor)  
KTEC - 35 - S85  
Coil resistance  
kΩ  
32 °F : 16.5  
41 °F : 12.8  
50 °F : 10.0  
68 °F : 6.3  
86 °F : 4.0  
,
,
,
,
,
104 °F : 2.7  
113 °F : 2.2  
122 °F : 1.8  
131 °F : 1.5  
1
Electronic expansion valve  
Valve body  
Coil  
HKV - 30D16  
EKV - MOZS559E0  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
SM830082  
I - 32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-3 Other Component Specifications  
(A) Indoor Unit  
MODEL No.  
KH2442  
Power Transformer  
ATR – IIK244B  
AC 220 V, 60 Hz  
Rated  
Primary  
Secondary  
Capacity  
BRN - BRN : 14 V / 0.55 A, RED - RED : 14 V / 0.3 A  
Coil resistance  
(Ambient temprature 77 °F)  
WHT - WHT  
BRN - BRN  
:
:
48.0  
0.45  
,
,
RED - RED  
ORG - ORG  
:
:
0.89  
2.05  
Thermistor cut off temperature  
Thermistor (Coil sensor)  
Coil resistance  
°F  
277  
PBC - 41E - S4  
kΩ  
14 °F : 23.7  
23 °F : 18.8  
32 °F : 15.0  
41 °F : 12.1  
50 °F : 9.7  
,
,
,
,
,
59 °F : 8.0  
68 °F : 6.5  
86 °F : 4.4  
104 °F : 3.1  
113 °F : 2.6  
Thermistor (Room or coil sensor)  
KTEC - 35 - S6  
Coil resistance  
kΩ  
32 °F : 16.5  
41 °F : 12.8  
50 °F : 10.0  
68 °F : 6.3  
86 °F : 4.0  
,
,
,
,
,
104 °F : 2.7  
113 °F : 2.2  
122 °F : 1.8  
131 °F : 1.5  
1
Solenoid control valve or coil  
Solenoid control valve  
Solenoid coil  
IKV - 24D11  
DKV - MOZS582E0  
M2EA24ZA01  
Synchronized Motor  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
SM830082  
I - 33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-3 Other Component Specifications  
(A) Indoor Unit  
MODEL No.  
KH3642  
Power Transformer  
ATR – II244B  
AC 220 V, 60 Hz  
Rated  
Primary  
Secondary  
Capacity  
BRN - BRN : 14 V / 0.55 A, RED - RED : 14 V / 0.3 A  
Coil resistance  
(Ambient temprature 77 °F)  
WHT - WHT  
BRN - BRN  
:
:
48.0  
0.45  
,
,
RED - RED  
ORG - ORG  
:
:
0.89  
2.05  
Thermistor cut off temperature  
Thermistor (Coil sensor)  
Coil resistance  
°F  
277  
PBC - 41E - S4  
kΩ  
14 °F : 23.7  
23 °F : 18.8  
32 °F : 15.0  
41 °F : 12.1  
50 °F : 9.7  
,
,
,
,
,
59 °F : 8.0  
68 °F : 6.5  
86 °F : 4.4  
104 °F : 3.1  
113 °F : 2.6  
Thermistor (Room or coil sensor)  
KTEC - 35 - S6  
Coil resistance  
kΩ  
32 °F : 16.5  
41 °F : 12.8  
50 °F : 10.0  
68 °F : 6.3  
86 °F : 4.0  
,
,
,
,
,
104 °F : 2.7  
113 °F : 2.2  
122 °F : 1.8  
131 °F : 1.5  
1
Electronic expansion valve  
Valve body  
HKV - 30D24  
EKV - MOZS557E0  
SW - KHS2432  
M2EA24ZA01  
Coil  
Switch Assy’s  
Synchronized Motor  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
SM830082  
I - 34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-3 Other Component Specifications  
(B) Outdoor Unit  
MODEL No.  
CH2442  
FC - 1UL  
Compressor Motor Magnetic Contactor  
Coil rated  
240 VAC, 60 Hz  
580 ± 15 %  
230 VAC, 20 A  
230 VAC, 3 A  
HH62S  
Coil resistance (at 77 °F)  
Contact rated (Main)  
Contact rated (Auxiliary)  
Power Relay  
Coil rated  
240 VAC, 60 Hz  
17.2  
Coil resistance (at 77 °F)  
Contact rated  
kΩ  
220 VAC, 5 A  
ATR - I65C  
Power Transformer  
Rated  
Primary  
220 VAC, 60 Hz  
14 V, 0.4 A  
5.6 VA  
Secondary  
Capacity  
1
Coil resistance (at 73 °F )  
Thermal cut off temperature  
Thermistor (Coil sensor) : TH6, 7  
Coil resistance  
WHT – WHT : 395.5  
,
266  
,
BRN – BRN : 2.19  
°F  
PBC - 41E - S4  
14 °F : 23.7  
23 °F : 18.8  
32 °F : 15.0  
41 °F : 12.1  
PBC - 41E - S26  
kΩ  
,
,
,
,
50 °F : 9.7  
68 °F : 6.5  
86 °F : 4.4  
104 °F : 3.1  
113 °F : 2.6  
Thermistor (Comp. discharge gas sensor) : TH8  
PTC - 51H - S1  
Coil resistance  
kΩ  
140 °F : 13.8  
158 °F : 9.7  
167 °F : 8.2  
176 °F : 7.0  
185 °F : 5.9  
,
,
,
,
,
194 °F : 5.1  
212 °F : 3.8  
230 °F : 2.8  
248 °F : 2.2  
266 °F : 1.7  
Solenoid control valve or coil  
Solenoid control valve  
Solenoid coil  
V 389100  
LB 59005  
Thermistor (PTC)  
Rated  
TDK – 101YV  
Max. voltage  
400 VAC  
Max. ampere  
11.5 A  
+ 30  
– 20  
Resistance (at 77 °F)  
100  
%
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
SM830082  
I - 35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-3 Other Component Specifications  
(B) Outdoor Unit  
MODEL No.  
CH3642  
FC - 1SUL  
Compressor Motor Magnetic Contactor  
Coil rated  
240 VAC, 60 Hz  
588 ± 10 %  
240 VAC, 26 A  
240 VAC, 3 A  
HH62S  
Coil resistance (at 68 °F)  
Contact rated (Main)  
Contact rated (Auxiliary)  
Power Relay  
Coil rated  
240 VAC, 60 Hz  
17.2  
Coil resistance (at 77 °F)  
Contact rated  
kΩ  
220 VAC, 5 A  
ATR - I65C  
Power Transformer  
Rated  
Primary  
220 VAC, 60 Hz  
14 V, 0.4 A  
5.6 VA  
Secondary  
Capacity  
1
Coil resistance (at 73 °F )  
Thermal cut off temperature  
Thermistor (Coil sensor) : TH6, 7  
Coil resistance  
WHT – WHT : 395.5  
,
266  
,
BRN – BRN : 2.19  
°F  
PBC - 41E - S4  
14 °F : 23.7  
23 °F : 18.8  
32 °F : 15.0  
41 °F : 12.1  
PBC - 41E - S36  
kΩ  
,
,
,
,
50 °F : 9.7  
68 °F : 6.5  
86 °F : 4.4  
104 °F : 3.1  
113 °F : 2.6  
Thermistor (Comp. discharge gas sensor) : TH8  
PTC - 51H - S1  
Coil resistance  
kΩ  
140 °F : 13.8  
158 °F : 9.7  
167 °F : 8.2  
176 °F : 7.0  
185 °F : 5.9  
,
,
,
,
,
194 °F : 5.1  
212 °F : 3.8  
230 °F : 2.8  
248 °F : 2.2  
266 °F : 1.7  
Solenoid control valve or coil  
Solenoid control valve  
Solenoid coil  
V 389100  
LB 59005  
Thermistor (PTC)  
Rated  
TDK – 101YV  
Max. voltage  
400 VAC  
Max. ampere  
11.5 A  
+ 30  
– 20  
Resistance (at 77 °F)  
100  
%
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
SM830082  
I - 36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-3 Other Component Specifications  
(B) Outdoor Unit  
MODEL No.  
CH4242  
FC - 2SUL  
Compressor Motor Magnetic Contactor  
Coil rated  
240 VAC, 60 Hz  
350 ± 10 %  
240 VAC, 35 A  
240 VAC, 3 A  
HH62S  
Coil resistance (at 68 °F)  
Contact rated (Main)  
Contact rated (Auxiliary)  
Power Relay  
Coil rated  
240 VAC, 60 Hz  
17.2  
Coil resistance (at 77 °F)  
Contact rated  
kΩ  
220 VAC, 5 A  
ATR - I65C  
Power Transformer  
Rated  
Primary  
220 VAC, 60 Hz  
14 V, 0.4 A  
5.6 VA  
Secondary  
Capacity  
1
Coil resistance (at 73 °F )  
Thermal cut off temperature  
Thermistor (Coil sensor) : TH6, 7  
Coil resistance  
WHT – WHT : 395.5  
,
266  
,
BRN – BRN : 2.19  
°F  
PBC - 41E - S4  
14 °F : 23.7  
23 °F : 18.8  
32 °F : 15.0  
41 °F : 12.1  
PBC - 41E - S36  
kΩ  
,
,
,
,
50 °F : 9.7  
68 °F : 6.5  
86 °F : 4.4  
104 °F : 3.1  
113 °F : 2.6  
Thermistor (Comp. discharge gas sensor) : TH8  
PTC - 51H - S1  
Coil resistance  
kΩ  
140 °F : 13.8  
158 °F : 9.7  
167 °F : 8.2  
176 °F : 7.0  
185 °F : 5.9  
,
,
,
,
,
194 °F : 5.1  
212 °F : 3.8  
230 °F : 2.8  
248 °F : 2.2  
266 °F : 1.7  
Solenoid control valve or coil  
Solenoid control valve  
Solenoid coil  
V 389100  
LB 59005  
Thermistor (PTC)  
Rated  
TDK – 101YV  
Max. voltage  
400 VAC  
Max. ampere  
11.5 A  
+ 30  
– 20  
Resistance (at 77 °F)  
100  
%
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
SM830082  
I - 37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-4 Dimensional data  
Indoor unit : 4-Way Air Discharge Semi-concealed Type  
24 Type  
10-9/32  
8-11/16  
4-7/8  
Min. 2-15/32  
Min. 19/32  
3
4-7/8  
2-5/16  
6-3/16  
7-5/32  
1
12-1/8  
4-7/8  
1-3/16  
32-9/32 (Ceiling opening)  
33-27/32  
19-11/16  
29-13/16 (Suspention bolt pitch)  
1-7/8  
4-7/8  
8-11/16  
2-3/8  
Dimension : inch  
Air intake grille  
Air outlet  
Refrigerant liquid line  
(3/8" : XH12, 18. 1/4" : XH24)  
Refrigerant gas line  
(1/2" : XH12. 5/8" : XH18. 3/4" : XH24)  
Drain connection  
Power supply entry (conduit size : 1/2")  
For discharge duct  
Suspention bolt mounting  
For fresh air intake  
8-27/32  
1917_X_S  
SM830082  
I - 38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-4 Dimensional data  
Indoor unit : 4-Way Air Discharge Semi-concealed Type  
36, 42 Type  
11-15/32  
9-19/32  
4-7/8  
Min. 2-15/32  
Min. 19/32  
3
2-5/16  
6-3/16  
7-5/32  
4-7/8  
32-9/32 (Ceiling opening)  
33-27/32  
19-11/16  
13-5/16  
4-7/8  
1-7/8  
1-3/16  
1
29-13/16 (Suspention bolt pitch)  
4-7/8  
9-19/32  
2-3/8  
Dimension : inch  
Air intake grille  
Air outlet  
Refrigerant liquid line (3/8")  
Refrigerant gas line (3/4")  
Drain connection  
Power supply entry (conduit size : 1/2")  
For discharge duct  
Suspention bolt mounting  
For fresh air intake  
9-13/16  
1918_X_S  
SM830082  
I - 39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-4 Dimensional data  
Indoor unit : Ceiling Mounted Type  
24 Type  
6-3/32  
3-15/16  
12-7/32  
11-1/32  
3-3/8  
5-3/4  
5-9/16  
11-1/32  
4-9/16  
3-9/32  
Holes in the rear side (View from front)  
Hole for wall-through piping (View from front)  
5-3/16  
2-25/32  
1
48-7/16 (Suspension bolt hole pitch)  
1-3/8  
50-13/32  
26-3/8  
10  
or more  
10  
or more  
Air outlet  
51-3/16  
Front  
9-7/8  
8-7/16  
9-7/8  
(Service space)  
(Service space)  
Air intake  
3-1/2  
4-1/16  
5-25/32  
7-7/32  
Dimension : inch  
Drain connection  
Drain connection for left side  
Refrigerant liquid line (1/4") Flare connection  
Refrigerant gas line (3/4") Flare connection  
Hole for rear side refrigerant tubing  
Hole for through-the-wall refrigerant tubing (ø3-15/16" hole)  
Hole for fresh air intake (Knockout hole)  
Hole for right side refrigerant tubing (Knockout hole)  
Hole for left side drain connection (Knockout hole)  
Hole for power supply (Conduit size 1/2")  
Infrared rays receiver for wireless remote controller  
Cutting position for fresh air intake  
1919_THS_I  
SM830082  
I - 40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-4 Dimensional data  
Indoor unit : Ceiling Mounted Type  
36, 42 Type  
6-3/32  
7-31/32  
12-7/32  
11-1/32  
3-3/8  
5-3/4  
5-9/16  
11-1/32  
4-3/4  
3-5/32  
Holes in the rear side (View from front)  
Hole for wall-through piping (View from front)  
5-3/16  
2-25/32  
1
59-1/4 (Suspension bolt hole pitch)  
1-3/8  
61-7/32  
26-3/8  
10  
or more  
10  
or more  
Air outlet  
62  
9-7/8  
8-7/16  
9-7/8  
Front  
(Service space)  
(Service space)  
Air intake  
3-1/2  
4-1/16  
5-25/32  
7-7/32  
Dimension : inch  
Drain connection  
Drain connection for left side  
Refrigerant liquid line (3/8") Flare connection  
Refrigerant gas line (3/4") Flare connection  
Hole for rear side refrigerant tubing  
Hole for through-the-wall refrigerant tubing (ø3-15/16" hole)  
Hole for fresh air intake (Knockout hole)  
Hole for right side refrigerant tubing (Knockout hole)  
Hole for left side drain connection (Knockout hole)  
Hole for power supply (Conduit size 1/2")  
Infrared rays receiver for wireless remote controller  
Cutting position for fresh air intake  
1920_TS_I  
SM830082  
I - 41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-4 Dimensional data  
Indoor unit : Concealed Duct Type  
24 Type  
10  
7-15/32  
31/32  
6-5/16  
1-3/16 2-3/4  
13/32  
31/32  
24-13/16  
3-11/32  
1
4-17/32  
10-1/4  
15/16  
11  
(Air outlet  
duct flange)  
22-27/32  
(Suspension bolt pitch)  
31/32  
Dimension : inch  
Refrigerant liquid line ø3/8 (narrow tube)  
(Use the tube connector)  
Refrigerant gas line ø5/8 (wide tube)  
Upper drain port (O.D. 1-1/4)  
Bottom drain port (O.D. 1-1/32)  
Suspension lug  
Power supply inlet (conduit size 1/2")  
Fresh air intake port (ø5-29/32)  
Flange for the flexible air outlet duct (ø7-7/8)  
Tube cover  
7-9/32  
9
10  
11  
Electrical component box  
Flange for the air intake duct  
(option or field supply)  
1914_U_I  
SM830082  
I - 42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-4 Dimensional data  
Indoor unit : Concealed Duct Type  
36 Type  
10  
7-15/32  
31/32  
6-5/16  
1-3/16 2-3/4  
24-13/16  
13/32  
31/32  
3-11/32  
1
4-17/32  
10-1/4  
15/16  
11  
(Air outlet  
duct flange)  
22-27/32  
(Suspension bolt pitch)  
31/32  
Dimension : inch  
Refrigerant liquid line ø3/8 (narrow tube)  
Refrigerant gas line ø3/4 (wide tube)  
Upper drain port (O.D. 1-1/4)  
Bottom drain port (O.D. 1-1/32)  
Suspension lug  
Power supply inlet (conduit size 1/2")  
Fresh air intake port (ø5-29/32)  
Flange for the flexible air outlet duct (ø7-7/8)  
Tube cover  
7-9/32  
9
10  
11  
Electrical component box  
Flange for the air intake duct  
(option or field supply)  
1915_U_I  
SM830082  
I - 43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-4 Dimensional data  
Indoor unit : Concealed Duct Type  
Flange for the air intake duct (Field supply)  
: For Concealed Duct Type  
Thickness more than T1/16 inch  
8-9/32  
31/32  
12-1/32  
31/32  
13/32  
10-1/4 (O.D.)  
29/32  
1
5/16  
1-25/32  
7-7/8  
1-25/32  
2118_U_I  
(mm)  
I
A
B
C
D
E
F
G
H
12, 18 type 27-15/32 26-1/16  
5/32  
1/4  
7-7/8  
3 × 7-7/8P = 23-5/8  
6-11/16  
13-3/4  
15/32  
24 type  
36 type  
39-9/32 37-7/8  
58-3/16 56-25/32  
7-3/32 5 × 7-3/32 = 35-7/16 4-23/32 9-21/32 (9-21/32 × 1) 9-27/32  
5/8  
9/32  
9-1/16 6 × 9-1/16 = 54-11/32 4-23/32 19-9/32 (9-21/32 × 2) 9-7/16  
25/32  
SM830082  
I - 44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-4 Dimensional data  
Indoor unit : Wall Mounted Type  
24 Type  
2-3/4  
49-7/32  
8-9/32  
1
4-5/32  
Refrigerant gas line (wide tubing: ø 3/4)  
Refrigerant liquid line (narrow tubing: ø 1/4)  
Drain hose OD 1-1/4  
Dimension : inch  
1911_X_S  
SM830082  
I - 45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-4 Dimensional data  
Indoor unit : Wall Mounted Type  
36 Type  
2-3/4  
59-1/16  
9-7/16  
1
2-9/16  
Refrigerant gas line (wide tubing 3/4")  
Refrigerant liquid line (narrow tubing 3/8")  
Drain hose OD 1-1/4  
Dimension : inch  
1912_X_S  
SM830082  
I - 46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-4 Dimensional Data  
(B) Outdoor Unit: CH2442  
6-11/16  
26  
4-21/64  
1-31/32  
1-31/32  
37  
1
Dimension : inch  
Hole for anchor bolt (4-ø1/2)  
Refrigerant tube joint (narrow tube)  
Flare connection 1/4 in (6.35 mm)  
Refrigerant tube joint (wide tube)  
Flare connection 3/4 in (19.05 mm)  
Refrigerant tubing inlet  
Power supply inlet  
2179_THS_I  
SM830082  
I - 47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-4 Dimensional Data  
(B) Outdoor Unit: CH3642, CH4242  
6-11/16  
26  
4-21/64  
1-31/32  
1-31/32  
37  
1
Dimension : inch  
Hole for anchor bolt (4-ø13)  
Refrigerant tube joint (narrow tube)  
Flare connection 3/8 in (9.52 mm)  
Refrigerant tube joint (wide tube)  
Flare connection 3/4 in (19.05 mm)  
Refrigerant tubing inlet  
Power supply inlet  
1581_C_S  
SM830082  
I - 48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-5 Refrigerant Flow Diagram  
Outdoor Unit: CH2442  
Indoor Unit: 24 Type  
Compressor  
Accumulator  
Accumulator  
Gas line  
service  
valve  
Gas line  
nipple  
O.D.  
3/4"  
(19.05mm)  
HP  
High  
pressure  
switch  
4-way valve  
EC  
Heat exchanger  
EC  
P
Heat exchanger  
Distributor  
Strainer  
P
Electronic  
ref.control  
valve  
Distributor  
Liquid line  
service  
valve  
M
Liquid line  
nipple  
O.D.  
1
1/4"  
(6.35mm)  
Strainer  
Sub-heat exchanger  
Cooling Cycle  
Heating Cycle  
2180_THS_I  
Outdoor Unit: CH3642  
Indoor Unit: 36 Type  
Compressor  
Accumulator  
Accumulator  
Gas line  
service  
valve  
Gas line  
nipple  
O.D.  
3/4"  
(19.05mm)  
HP  
High  
pressure  
switch  
Muffler  
4-way valve  
EC  
P
Heat exchanger  
EC  
Heat exchanger  
Distributor  
Strainer  
P
Electronic  
ref.control  
valve  
Distributor  
Liquid line  
service  
valve  
M
Liquid line  
nipple  
O.D.  
3/8"  
(9.52mm)  
Strainer  
Sub-heat exchanger  
Cooling Cycle  
Heating Cycle  
1398_THS_I  
SM830082  
I - 49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-5 Refrigerant Flow Diagram  
Outdoor Unit: CH4242  
Indoor Unit: 42 Type  
Compressor  
Accumulator  
Gas line  
service  
valve  
Gas line  
nipple  
O.D.  
3/4"  
(19.05mm)  
HP  
High  
pressure  
switch  
Muffler  
4-way valve  
EC  
Heat exchanger  
EC  
P
Heat exchanger  
Distributor  
Distributor  
Strainer  
P
Electronic  
ref.control  
valve  
Liquid line  
service  
valve  
M
Liquid line  
nipple  
O.D.  
1
3/8"  
(9.52mm)  
Strainer  
Sub-heat exchanger  
Cooling Cycle  
Heating Cycle  
2181_THS_I  
1-6 Operating Range  
Temperature  
Indoor Air Intake  
Outdoor Air Intake  
Maximum  
Minimum  
Maximum  
Minimum  
95 °F DB, 71 °F WB 115 °F DB  
67 °F DB, 57 °F WB 0 °F DB  
Cooling  
Heating  
80 °F DB, 67 °F WB 75 °F DB, 65 °F WB  
-DB / -WB  
17 °F DB / 15 °F WB  
SM830082  
I - 50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-7 Cooling Capacity  
Indoor Unit: XH2442 Outdoor Unit: CH2442  
• 230V / 1 phase / 60Hz  
RATING CAPACITY :  
EVAPORATOR  
24,000 BTU/h  
AIR FLOW RATE:  
CONDENSER  
540 CFM  
ENT.TEMP.°F(°C)  
AMBIENT TEMP °F(°C)  
WB  
DB  
75  
85  
95  
105  
115  
(23.9)  
24,310  
1.71  
(29.4)  
(35.0)  
21,790  
2.03  
(40.6)  
(46.1)  
TC  
CI  
23,140  
1.86  
20,280  
2.26  
18,600  
2.49  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
16,680  
18,480  
20,360  
22,160  
23,960  
25,220  
1.72  
16,020  
17,820  
19,700  
21,500  
23,140  
24,100  
1.89  
15,280  
17,080  
18,960  
20,760  
21,790  
22,900  
2.06  
14,470  
16,270  
18,150  
19,950  
20,280  
21,530  
2.29  
13,600  
15,400  
17,280  
18,600  
18,600  
20,040  
2.52  
59  
(15.0)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
14,330  
16,130  
18,010  
19,810  
21,610  
26,180  
1.74  
13,750  
15,550  
17,430  
19,230  
21,030  
25,150  
1.9  
13,140  
14,940  
16,820  
18,620  
20,420  
# 24,000  
2.08  
12,460  
14,260  
16,140  
17,940  
19,740  
22,730  
2.32  
11,750  
13,550  
15,430  
17,230  
19,030  
21,340  
2.55  
63  
(17.2)  
1
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
11,960  
13,760  
15,640  
17,440  
19,240  
27,580  
1.76  
11,470  
13,270  
15,150  
16,950  
18,750  
26,620  
1.92  
10,940  
12,740  
14,620  
16,420  
18,220  
25,580  
2.11  
10,360  
12,160  
14,040  
15,840  
17,640  
24,460  
2.35  
9,750  
67  
11,550  
13,430  
15,230  
17,030  
23,210  
2.59  
(19.4)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
9,650  
9,230  
8,790  
8,330  
7,820  
71  
11,450  
13,330  
15,130  
16,930  
28,130  
1.79  
11,030  
12,910  
14,710  
16,510  
27,220  
1.96  
10,590  
12,470  
14,270  
16,070  
26,260  
2.14  
10,130  
12,010  
13,810  
15,610  
25,150  
2.38  
9,620  
(21.7)  
11,500  
13,300  
15,100  
23,980  
2.63  
CI  
75  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
8,850  
8,500  
8,130  
7,720  
7,290  
(23.9)  
10,730  
12,530  
14,330  
10,380  
12,180  
13,980  
10,010  
11,810  
13,610  
9,600  
9,170  
11,400  
13,200  
10,970  
12,770  
TC :Total Cooling Capacity (BTU/h)  
SHC:Sensible Heat Capacity (BTU/h)  
CI :Compressor Input (kW)  
Rating conditions are  
:Outdoor Ambient Temp.95° FDB  
:Indoor Unit Entering Air Temp.80° FDB/67° FWB  
SM830082  
I - 51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor Unit: XH2442 Outdoor Unit: CH2442  
• 208V / 1 phase / 60Hz  
RATING CAPACITY :  
EVAPORATOR  
23,400 BTU/h  
AIR FLOW RATE:  
CONDENSER  
510 CFM  
ENT.TEMP.°F(°C)  
AMBIENT TEMP °F(°C)  
WB  
DB  
75  
85  
95  
105  
115  
(23.9)  
23,700  
1.75  
(29.4)  
(35.0)  
(40.6)  
(46.1)  
TC  
CI  
22,560  
1.92  
21,250  
2.09  
19,770  
2.33  
18,140  
2.56  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
16,220  
17,930  
19,730  
21,440  
23,160  
15,570  
17,280  
19,080  
20,790  
22,510  
14,840  
16,560  
18,350  
20,060  
21,250  
14,040  
15,760  
17,550  
19,270  
19,770  
13,190  
14,910  
16,700  
18,140  
18,140  
59  
(15.0)  
TC  
CI  
24,590  
1.77  
23,490  
1.94  
22,320  
2.12  
20,990  
2.36  
19,540  
2.6  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
13,970  
15,680  
17,470  
19,190  
20,900  
25,530  
1.79  
13,390  
15,110  
16,900  
18,610  
20,330  
24,520  
1.96  
12,790  
14,510  
16,300  
18,010  
19,730  
# 23,400  
2.14  
12,130  
13,840  
15,640  
17,350  
19,070  
22,160  
2.39  
11,430  
13,140  
14,940  
16,650  
18,360  
20,800  
2.63  
63  
(17.2)  
1
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
11,700  
13,410  
15,210  
16,920  
18,640  
26,890  
1.81  
11,220  
12,930  
14,720  
16,440  
18,150  
25,950  
1.98  
10,690  
12,410  
14,200  
15,910  
17,630  
24,940  
2.17  
10,130  
11,840  
13,630  
15,350  
17,060  
23,840  
2.42  
9,520  
67  
11,230  
13,030  
14,740  
16,450  
22,630  
2.67  
(19.4)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
9,480  
9,070  
8,640  
8,180  
7,680  
71  
11,200  
12,990  
14,700  
16,420  
27,420  
1.84  
10,790  
12,580  
14,300  
16,010  
26,540  
2.01  
10,360  
12,150  
13,860  
15,580  
25,600  
2.2  
9,890  
9,400  
(21.7)  
11,690  
13,400  
15,120  
24,520  
2.46  
11,190  
12,900  
14,620  
23,380  
2.71  
CI  
75  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
8,700  
8,360  
8,000  
7,590  
7,170  
(23.9)  
10,490  
12,210  
13,920  
10,150  
11,870  
13,580  
9,790  
9,380  
8,960  
11,500  
13,220  
11,100  
12,810  
10,670  
12,390  
TC :Total Cooling Capacity (BTU/h)  
SHC:Sensible Heat Capacity (BTU/h)  
CI :Compressor Input (kW)  
Rating conditions are  
:Outdoor Ambient Temp.95° FDB  
:Indoor Unit Entering Air Temp.80° FDB/67° FWB  
SM830082  
I - 52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor Unit: XH3642 Outdoor Unit: CH3642  
• 230V / 1 phase / 60Hz  
RATING CAPACITY :  
EVAPORATOR  
34,500 BTU/h  
AIR FLOW RATE:  
CONDENSER  
980 CFM  
ENT.TEMP.°F(°C)  
AMBIENT TEMP °F(°C)  
WB  
DB  
75  
85  
95  
105  
115  
(23.9)  
34,950  
2.32  
(29.4)  
(35.0)  
31,330  
2.76  
(40.6)  
(46.1)  
TC  
CI  
33,260  
2.53  
29,150  
3.06  
26,740  
3.36  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
25,700  
29,070  
32,590  
34,950  
34,950  
36,260  
2.34  
24,850  
28,220  
31,740  
33,260  
33,260  
34,640  
2.57  
23,890  
27,260  
30,790  
31,330  
31,330  
32,910  
2.8  
22,840  
26,210  
29,150  
29,150  
29,150  
30,950  
3.11  
21,700  
25,070  
26,740  
26,740  
26,740  
28,810  
3.42  
59  
(15.0)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
21,580  
24,950  
28,480  
31,850  
35,220  
37,640  
2.36  
20,830  
24,200  
27,730  
31,100  
34,470  
36,160  
2.59  
20,050  
23,420  
26,940  
30,310  
32,910  
# 34,500  
2.83  
19,170  
22,540  
26,060  
29,430  
30,950  
32,670  
3.14  
18,230  
21,600  
25,130  
28,500  
28,810  
30,670  
3.45  
63  
(17.2)  
1
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
17,450  
20,820  
24,340  
27,710  
31,080  
39,640  
2.39  
16,820  
20,190  
23,710  
27,080  
30,450  
38,260  
2.62  
16,130  
19,500  
23,020  
26,390  
29,760  
36,780  
2.87  
15,380  
18,750  
22,270  
25,640  
29,010  
35,160  
3.19  
14,570  
17,940  
21,470  
24,840  
28,210  
33,360  
3.5  
67  
(19.4)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
13,330  
16,700  
20,220  
23,590  
26,960  
40,430  
2.43  
12,800  
16,170  
19,690  
23,060  
26,430  
39,120  
2.66  
12,240  
15,610  
19,130  
22,500  
25,870  
37,740  
2.91  
11,630  
15,000  
18,520  
21,890  
25,260  
36,160  
3.23  
10,960  
14,330  
17,860  
21,230  
24,600  
34,470  
3.55  
71  
(21.7)  
CI  
75  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
12,270  
15,800  
19,170  
22,540  
11,820  
15,340  
18,710  
22,080  
11,350  
14,870  
18,240  
21,610  
10,810  
14,330  
17,700  
21,070  
10,250  
13,770  
17,140  
20,510  
(23.9)  
TC :Total Cooling Capacity (BTU/h)  
SHC:Sensible Heat Capacity (BTU/h)  
CI :Compressor Input (kW)  
Rating conditions are  
:Outdoor Ambient Temp.95° FDB  
:Indoor Unit Entering Air Temp.80° FDB/67° FWB  
SM830082  
I - 53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor Unit: XH3642 Outdoor Unit: CH3642  
• 208V / 1 phase / 60Hz  
RATING CAPACITY :  
EVAPORATOR  
33,500 BTU/h  
AIR FLOW RATE:  
CONDENSER  
880 CFM  
ENT.TEMP.°F(°C)  
AMBIENT TEMP °F(°C)  
WB  
DB  
75  
85  
95  
105  
115  
(23.9)  
33,940  
2.21  
(29.4)  
(35.0)  
30,420  
2.62  
(40.6)  
(46.1)  
TC  
CI  
32,290  
2.41  
28,310  
2.96  
25,960  
3.3  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
24,520  
27,600  
30,810  
33,890  
33,940  
35,210  
2.23  
23,670  
26,750  
29,960  
32,290  
32,290  
33,630  
2.44  
22,730  
25,810  
29,020  
30,420  
30,420  
31,960  
2.66  
21,690  
24,760  
27,980  
28,310  
28,310  
30,050  
3
20,560  
23,630  
25,960  
25,960  
25,960  
27,970  
3.35  
59  
(15.0)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
20,720  
23,790  
27,010  
30,080  
33,160  
36,550  
2.25  
19,970  
23,050  
26,260  
29,340  
32,410  
35,110  
2.46  
19,200  
22,270  
25,490  
28,560  
31,640  
# 33,500  
2.69  
18,330  
21,400  
24,620  
27,690  
30,050  
31,720  
3.04  
17,400  
20,470  
23,690  
26,760  
27,970  
29,780  
3.38  
63  
(17.2)  
1
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
16,900  
19,970  
23,190  
26,260  
29,340  
38,490  
2.27  
16,270  
19,350  
22,560  
25,640  
28,710  
37,150  
2.49  
15,590  
18,660  
21,880  
24,950  
28,030  
35,710  
2.73  
14,840  
17,920  
21,130  
24,210  
27,280  
34,140  
3.08  
14,050  
17,120  
20,340  
23,410  
26,490  
32,390  
3.43  
67  
(19.4)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
13,100  
16,180  
19,390  
22,470  
25,540  
39,260  
2.31  
12,570  
15,650  
18,860  
21,940  
25,010  
37,990  
2.53  
12,010  
15,090  
18,300  
21,380  
24,450  
36,650  
2.77  
11,410  
14,490  
17,700  
20,780  
23,850  
35,110  
3.13  
10,750  
13,830  
17,040  
20,120  
23,190  
33,470  
3.48  
71  
(21.7)  
CI  
75  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
12,060  
15,280  
18,350  
21,430  
11,610  
14,830  
17,900  
20,980  
11,150  
14,360  
17,440  
20,510  
10,610  
13,830  
16,900  
19,980  
10,060  
13,270  
16,350  
19,420  
(23.9)  
TC :Total Cooling Capacity (BTU/h)  
SHC:Sensible Heat Capacity (BTU/h)  
CI :Compressor Input (kW)  
Rating conditions are  
:Outdoor Ambient Temp.95° FDB  
:Indoor Unit Entering Air Temp.80° FDB/67° FWB  
SM830082  
I - 54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor Unit: XH4242 Outdoor Unit: CH4242  
• 230V / 1 phase / 60Hz  
RATING CAPACITY :  
EVAPORATOR  
42,000 BTU/h  
AIR FLOW RATE:  
CONDENSER  
980 CFM  
ENT.TEMP.°F(°C)  
AMBIENT TEMP °F(°C)  
WB  
DB  
75  
85  
95  
105  
115  
(23.9)  
42,550  
3.03  
(29.4)  
(35.0)  
38,140  
3.6  
(40.6)  
(46.1)  
TC  
CI  
40,490  
3.3  
35,490  
4.02  
32,550  
4.44  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
29,690  
33,060  
36,580  
39,950  
42,550  
44,140  
3.06  
28,560  
31,930  
35,460  
38,830  
40,490  
42,170  
3.35  
27,310  
30,680  
34,210  
37,580  
38,140  
40,070  
3.65  
25,940  
29,310  
32,830  
35,490  
35,490  
37,670  
4.08  
24,460  
27,830  
31,350  
32,550  
32,550  
35,070  
4.5  
59  
(15.0)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
25,370  
28,740  
32,270  
35,640  
39,010  
45,820  
3.08  
24,390  
27,760  
31,280  
34,650  
38,020  
44,020  
3.38  
23,360  
26,730  
30,250  
33,620  
36,990  
# 42,000  
3.69  
22,210  
25,580  
29,100  
32,470  
35,840  
39,770  
4.12  
20,990  
24,360  
27,890  
31,260  
34,630  
37,340  
4.55  
63  
(17.2)  
1
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
21,040  
24,410  
27,930  
31,300  
34,670  
48,260  
3.11  
20,210  
23,580  
27,110  
30,480  
33,850  
46,580  
3.41  
19,310  
22,680  
26,200  
29,570  
32,940  
44,770  
3.75  
18,330  
21,700  
25,220  
28,590  
31,960  
42,800  
4.18  
17,280  
20,650  
24,170  
27,540  
30,910  
40,610  
4.62  
67  
(19.4)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
16,770  
20,140  
23,660  
27,030  
30,400  
49,220  
3.17  
16,070  
19,440  
22,960  
26,330  
29,700  
47,630  
3.47  
15,330  
18,700  
22,220  
25,590  
28,960  
45,950  
3.8  
14,530  
17,900  
21,430  
24,800  
28,170  
44,020  
4.24  
13,670  
17,040  
20,560  
23,930  
27,300  
41,960  
4.69  
71  
(21.7)  
CI  
75  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
15,420  
18,940  
22,310  
25,680  
14,820  
18,350  
21,720  
25,090  
14,200  
17,730  
21,100  
24,470  
13,500  
17,020  
20,400  
23,770  
12,770  
16,290  
19,660  
23,030  
(23.9)  
TC :Total Cooling Capacity (BTU/h)  
SHC:Sensible Heat Capacity (BTU/h)  
CI :Compressor Input (kW)  
Rating conditions are  
:Outdoor Ambient Temp.95° FDB  
:Indoor Unit Entering Air Temp.80° FDB/67° FWB  
SM830082  
I - 55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor Unit: XH4242 Outdoor Unit: CH4242  
• 208V / 1 phase / 60Hz  
RATING CAPACITY :  
EVAPORATOR  
40,000 BTU/h  
AIR FLOW RATE:  
CONDENSER  
880 CFM  
ENT.TEMP.°F(°C)  
AMBIENT TEMP °F(°C)  
WB  
DB  
75  
85  
95  
105  
115  
(23.9)  
40,520  
2.91  
(29.4)  
(35.0)  
36,320  
3.46  
(40.6)  
(46.1)  
TC  
CI  
38,560  
3.18  
33,800  
3.92  
31,000  
4.38  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
28,050  
31,120  
34,340  
37,410  
40,490  
42,040  
2.94  
26,960  
30,040  
33,250  
36,330  
38,560  
40,160  
3.22  
25,750  
28,820  
32,040  
35,110  
36,320  
38,160  
3.51  
24,420  
27,490  
30,710  
33,780  
33,800  
35,880  
3.98  
22,990  
26,060  
29,280  
31,000  
31,000  
33,400  
4.45  
59  
(15.0)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
24,070  
27,150  
30,360  
33,440  
36,510  
43,640  
2.96  
23,110  
26,190  
29,400  
32,480  
35,550  
41,920  
3.25  
22,120  
25,190  
28,410  
31,480  
34,560  
# 40,000  
3.55  
21,010  
24,080  
27,300  
30,370  
33,450  
37,880  
4.02  
19,830  
22,900  
26,120  
29,190  
32,270  
35,560  
4.49  
63  
(17.2)  
1
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
20,070  
23,150  
26,360  
29,440  
32,510  
45,960  
3
19,270  
22,340  
25,560  
28,630  
31,710  
44,360  
3.28  
18,390  
21,470  
24,680  
27,760  
30,830  
42,640  
3.6  
17,440  
20,520  
23,730  
26,810  
29,880  
40,760  
4.08  
16,430  
19,500  
22,720  
25,790  
28,870  
38,680  
4.56  
67  
(19.4)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
16,140  
19,220  
22,430  
25,510  
28,580  
46,880  
3.05  
15,460  
18,540  
21,750  
24,830  
27,900  
45,360  
3.34  
14,740  
17,820  
21,030  
24,110  
27,180  
43,760  
3.66  
13,970  
17,050  
20,260  
23,340  
26,410  
41,920  
4.14  
13,140  
16,210  
19,430  
22,500  
25,580  
39,960  
4.62  
71  
(21.7)  
CI  
75  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
14,840  
18,060  
21,130  
24,210  
14,260  
17,480  
20,550  
23,630  
13,660  
16,880  
19,950  
23,030  
12,980  
16,200  
19,270  
22,350  
12,270  
15,490  
18,560  
21,640  
(23.9)  
TC :Total Cooling Capacity (BTU/h)  
SHC:Sensible Heat Capacity (BTU/h)  
CI :Compressor Input (kW)  
Rating conditions are  
:Outdoor Ambient Temp.95° FDB  
:Indoor Unit Entering Air Temp.80° FDB/67° FWB  
SM830082  
I - 56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor Unit: TH2442 Outdoor Unit: CH2442  
• 230V / 1 phase / 60Hz  
RATING CAPACITY :  
EVAPORATOR  
22,400 BTU/h  
AIR FLOW RATE:  
CONDENSER  
460 CFM  
ENT.TEMP.°F(°C)  
AMBIENT TEMP °F(°C)  
WB  
DB  
75  
85  
95  
105  
115  
(23.9)  
22,690  
1.71  
(29.4)  
(35.0)  
20,340  
2.03  
(40.6)  
(46.1)  
TC  
CI  
21,590  
1.86  
18,930  
2.26  
17,360  
2.49  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
15,520  
17,140  
18,840  
20,460  
22,090  
23,540  
1.72  
14,890  
16,510  
18,210  
19,830  
21,460  
22,490  
1.89  
14,190  
15,820  
17,510  
19,140  
20,340  
21,370  
2.06  
13,430  
15,050  
16,750  
18,370  
18,930  
20,090  
2.29  
12,610  
14,230  
15,930  
17,360  
17,360  
18,700  
2.52  
59  
(15.0)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
13,380  
15,000  
16,700  
18,320  
19,950  
24,440  
1.74  
12,830  
14,450  
16,150  
17,770  
19,400  
23,480  
1.9  
12,250  
13,880  
15,570  
17,200  
18,820  
# 22,400  
2.08  
11,610  
13,240  
14,930  
16,560  
18,180  
21,210  
2.32  
10,940  
12,560  
14,260  
15,880  
17,500  
19,910  
2.55  
63  
(17.2)  
1
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
11,230  
12,850  
14,550  
16,170  
17,800  
25,740  
1.76  
10,770  
12,390  
14,090  
15,710  
17,340  
24,840  
1.92  
10,260  
11,880  
13,580  
15,200  
16,830  
23,880  
2.11  
9,710  
9,130  
67  
11,340  
13,030  
14,660  
16,280  
22,830  
2.35  
10,750  
12,450  
14,080  
15,700  
21,660  
2.59  
(19.4)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
9,130  
8,730  
8,320  
7,880  
7,390  
71  
10,750  
12,450  
14,070  
15,690  
26,250  
1.79  
10,360  
12,050  
13,680  
15,300  
25,400  
1.96  
9,940  
9,500  
9,020  
(21.7)  
11,640  
13,260  
14,890  
24,510  
2.14  
11,200  
12,820  
14,440  
23,480  
2.38  
10,710  
12,340  
13,960  
22,380  
2.63  
CI  
75  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
8,380  
8,050  
7,700  
7,310  
6,900  
(23.9)  
10,080  
11,700  
13,320  
9,740  
9,400  
9,010  
8,600  
11,370  
12,990  
11,020  
12,650  
10,630  
12,250  
10,220  
11,850  
TC :Total Cooling Capacity (BTU/h)  
SHC:Sensible Heat Capacity (BTU/h)  
CI :Compressor Input (kW)  
Rating conditions are  
:Outdoor Ambient Temp.95° FDB  
:Indoor Unit Entering Air Temp.80° FDB/67° FWB  
SM830082  
I - 57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor Unit: TH2442 Outdoor Unit: CH2442  
• 208V / 1 phase / 60Hz  
RATING CAPACITY :  
EVAPORATOR  
21,600 BTU/h  
AIR FLOW RATE:  
CONDENSER  
410 CFM  
ENT.TEMP.°F(°C)  
AMBIENT TEMP °F(°C)  
WB  
DB  
75  
85  
95  
105  
115  
(23.9)  
21,880  
1.75  
(29.4)  
(35.0)  
19,610  
2.09  
(40.6)  
(46.1)  
TC  
CI  
20,820  
1.92  
18,250  
2.33  
16,740  
2.56  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
14,850  
16,320  
17,860  
19,330  
20,800  
22,700  
1.77  
14,220  
15,690  
17,230  
18,700  
20,170  
21,690  
1.94  
13,530  
15,000  
16,540  
18,010  
19,480  
20,610  
2.12  
12,770  
14,240  
15,780  
17,250  
18,250  
19,380  
2.36  
11,960  
13,430  
14,970  
16,440  
16,740  
18,040  
2.6  
59  
(15.0)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
12,870  
14,340  
15,880  
17,350  
18,820  
23,570  
1.79  
12,320  
13,800  
15,330  
16,800  
18,280  
22,640  
1.96  
11,750  
13,220  
14,760  
16,230  
17,700  
# 21,600  
2.14  
11,120  
12,590  
14,130  
15,600  
17,070  
20,460  
2.39  
10,450  
11,920  
13,460  
14,930  
16,400  
19,200  
2.63  
63  
(17.2)  
1
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
10,890  
12,360  
13,900  
15,370  
16,840  
24,820  
1.81  
10,420  
11,900  
13,430  
14,910  
16,380  
23,950  
1.98  
9,920  
9,380  
8,800  
67  
11,390  
12,930  
14,400  
15,870  
23,030  
2.17  
10,850  
12,390  
13,860  
15,330  
22,010  
2.42  
10,270  
11,810  
13,280  
14,750  
20,890  
2.67  
(19.4)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
8,950  
8,560  
8,150  
7,710  
7,230  
71  
10,420  
11,960  
13,430  
14,900  
25,320  
1.84  
10,030  
11,570  
13,040  
14,510  
24,490  
2.01  
9,620  
9,180  
8,700  
(21.7)  
11,160  
12,630  
14,100  
23,630  
2.2  
10,720  
12,190  
13,660  
22,640  
2.46  
10,240  
11,710  
13,180  
21,580  
2.71  
CI  
75  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
8,220  
7,880  
7,540  
7,150  
6,750  
(23.9)  
9,760  
9,420  
9,080  
8,690  
8,290  
11,230  
12,700  
10,890  
12,360  
10,550  
12,020  
10,160  
11,630  
9,760  
11,230  
TC :Total Cooling Capacity (BTU/h)  
SHC:Sensible Heat Capacity (BTU/h)  
CI :Compressor Input (kW)  
Rating conditions are  
:Outdoor Ambient Temp.95° FDB  
:Indoor Unit Entering Air Temp.80° FDB/67° FWB  
SM830082  
I - 58  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor Unit: TH3642 Outdoor Unit: CH3642  
• 230V / 1 phase / 60Hz  
RATING CAPACITY :  
EVAPORATOR  
34,000 BTU/h  
AIR FLOW RATE:  
CONDENSER  
900 CFM  
ENT.TEMP.°F(°C)  
AMBIENT TEMP °F(°C)  
WB  
DB  
75  
85  
95  
105  
115  
(23.9)  
34,440  
2.32  
(29.4)  
(35.0)  
30,870  
2.76  
(40.6)  
(46.1)  
TC  
CI  
32,780  
2.53  
28,730  
3.06  
26,350  
3.36  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
24,970  
28,140  
31,460  
34,440  
34,440  
35,730  
2.34  
24,120  
27,290  
30,610  
32,780  
32,780  
34,140  
2.57  
23,160  
26,330  
29,650  
30,870  
30,870  
32,440  
2.8  
22,110  
25,280  
28,600  
28,730  
28,730  
30,500  
3.11  
20,970  
24,140  
26,350  
26,350  
26,350  
28,390  
3.42  
59  
(15.0)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
21,060  
24,230  
27,540  
30,720  
33,890  
37,090  
2.36  
20,310  
23,480  
26,800  
29,970  
33,140  
35,630  
2.59  
19,520  
22,690  
26,010  
29,180  
32,350  
# 34,000  
2.83  
18,640  
21,810  
25,130  
28,300  
30,500  
32,200  
3.14  
17,710  
20,880  
24,190  
27,370  
28,390  
30,230  
3.45  
63  
(17.2)  
1
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
17,120  
20,300  
23,610  
26,780  
29,960  
39,070  
2.39  
16,500  
19,670  
22,980  
26,160  
29,330  
37,710  
2.62  
15,810  
18,980  
22,290  
25,470  
28,640  
36,240  
2.87  
15,060  
18,230  
21,550  
24,720  
27,890  
34,650  
3.19  
14,250  
17,420  
20,740  
23,910  
27,080  
32,880  
3.5  
67  
(19.4)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
13,220  
16,400  
19,710  
22,880  
26,060  
39,850  
2.43  
12,690  
15,860  
19,180  
22,350  
25,520  
38,560  
2.66  
12,120  
15,290  
18,610  
21,780  
24,950  
37,200  
2.91  
11,520  
14,690  
18,000  
21,180  
24,350  
35,630  
3.23  
10,850  
14,020  
17,340  
20,510  
23,680  
33,970  
3.55  
71  
(21.7)  
CI  
75  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
12,170  
15,490  
18,660  
21,830  
11,720  
15,030  
18,200  
21,380  
11,240  
14,560  
17,730  
20,900  
10,700  
14,020  
17,190  
20,360  
10,140  
13,460  
16,630  
19,800  
(23.9)  
TC :Total Cooling Capacity (BTU/h)  
SHC:Sensible Heat Capacity (BTU/h)  
CI :Compressor Input (kW)  
Rating conditions are  
:Outdoor Ambient Temp.95° FDB  
:Indoor Unit Entering Air Temp.80° FDB/67° FWB  
SM830082  
I - 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor Unit: TH3642 Outdoor Unit: CH3642  
• 208V / 1 phase / 60Hz  
RATING CAPACITY :  
EVAPORATOR  
33,000 BTU/h  
AIR FLOW RATE:  
CONDENSER  
800 CFM  
ENT.TEMP.°F(°C)  
AMBIENT TEMP °F(°C)  
WB  
DB  
75  
85  
95  
105  
115  
(23.9)  
33,430  
2.21  
(29.4)  
(35.0)  
29,960  
2.62  
(40.6)  
(46.1)  
TC  
CI  
31,810  
2.41  
27,890  
2.96  
25,580  
3.3  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
23,800  
26,660  
29,660  
32,530  
33,430  
34,680  
2.23  
22,940  
25,810  
28,810  
31,680  
31,810  
33,130  
2.44  
21,990  
24,860  
27,860  
29,960  
29,960  
31,480  
2.66  
20,950  
23,820  
26,810  
27,890  
27,890  
29,600  
3
19,820  
22,690  
25,580  
25,580  
25,580  
27,560  
3.35  
59  
(15.0)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
20,200  
23,070  
26,070  
28,930  
31,800  
36,000  
2.25  
19,450  
22,320  
25,320  
28,190  
31,050  
34,580  
2.46  
18,670  
21,540  
24,540  
27,400  
30,270  
# 33,000  
2.69  
17,800  
20,670  
23,660  
26,530  
29,400  
31,250  
3.04  
16,870  
19,740  
22,740  
25,600  
27,560  
29,340  
3.38  
63  
(17.2)  
1
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
16,590  
19,460  
22,460  
25,320  
28,190  
37,920  
2.27  
15,960  
18,830  
21,830  
24,700  
27,560  
36,600  
2.49  
15,280  
18,140  
21,140  
24,010  
26,880  
35,180  
2.73  
14,530  
17,400  
20,400  
23,260  
26,130  
33,630  
3.08  
13,730  
16,600  
19,600  
22,470  
25,330  
31,910  
3.43  
67  
(19.4)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
13,020  
15,890  
18,890  
21,750  
24,620  
38,680  
2.31  
12,490  
15,360  
18,350  
21,220  
24,090  
37,420  
2.53  
11,930  
14,790  
17,790  
20,660  
23,530  
36,100  
2.77  
11,320  
14,190  
17,190  
20,050  
22,920  
34,580  
3.13  
10,660  
13,530  
16,530  
19,390  
22,260  
32,970  
3.48  
71  
(21.7)  
CI  
75  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
11,990  
14,980  
17,850  
20,720  
11,530  
14,530  
17,390  
20,260  
11,060  
14,060  
16,920  
19,790  
10,520  
13,520  
16,390  
19,260  
9,970  
(23.9)  
12,960  
15,830  
18,700  
TC :Total Cooling Capacity (BTU/h)  
SHC:Sensible Heat Capacity (BTU/h)  
CI :Compressor Input (kW)  
Rating conditions are  
:Outdoor Ambient Temp.95° FDB  
:Indoor Unit Entering Air Temp.80° FDB/67° FWB  
SM830082  
I - 60  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor Unit: TH4242 Outdoor Unit: CH4242  
• 230V / 1 phase / 60Hz  
RATING CAPACITY :  
EVAPORATOR  
42,000 BTU/h  
AIR FLOW RATE:  
CONDENSER  
900 CFM  
ENT.TEMP.°F(°C)  
AMBIENT TEMP °F(°C)  
WB  
DB  
75  
85  
95  
105  
115  
(23.9)  
42,550  
3.03  
(29.4)  
(35.0)  
38,140  
3.6  
(40.6)  
(46.1)  
TC  
CI  
40,490  
3.3  
35,490  
4.02  
32,550  
4.44  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
29,360  
32,530  
35,850  
39,020  
42,190  
44,140  
3.06  
28,200  
31,380  
34,690  
37,860  
40,490  
42,170  
3.35  
26,920  
30,090  
33,410  
36,580  
38,140  
40,070  
3.65  
25,510  
28,690  
32,000  
35,170  
35,490  
37,670  
4.08  
24,000  
27,170  
30,490  
32,550  
32,550  
35,070  
4.5  
59  
(15.0)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
25,230  
28,400  
31,720  
34,890  
38,060  
45,820  
3.08  
24,220  
27,390  
30,710  
33,880  
37,050  
44,020  
3.38  
23,160  
26,340  
29,650  
32,820  
36,000  
# 42,000  
3.69  
21,990  
25,160  
28,470  
31,650  
34,820  
39,770  
4.12  
20,740  
23,920  
27,230  
30,400  
33,580  
37,340  
4.55  
63  
(17.2)  
1
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
21,080  
24,260  
27,570  
30,740  
33,920  
48,260  
3.11  
20,240  
23,410  
26,730  
29,900  
33,070  
46,580  
3.41  
19,310  
22,480  
25,790  
28,970  
32,140  
44,770  
3.75  
18,300  
21,470  
24,790  
27,960  
31,130  
42,800  
4.18  
17,230  
20,410  
23,720  
26,890  
30,070  
40,610  
4.62  
67  
(19.4)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
17,020  
20,190  
23,510  
26,680  
29,850  
49,220  
3.17  
16,300  
19,470  
22,790  
25,960  
29,130  
47,630  
3.47  
15,540  
18,710  
22,020  
25,200  
28,370  
45,950  
3.8  
14,720  
17,890  
21,210  
24,380  
27,550  
44,020  
4.24  
13,840  
17,010  
20,320  
23,500  
26,670  
41,960  
4.69  
71  
(21.7)  
CI  
75  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
15,640  
18,960  
22,130  
25,300  
15,030  
18,350  
21,520  
24,690  
14,400  
17,710  
20,880  
24,060  
13,680  
16,990  
20,170  
23,340  
12,930  
16,240  
19,410  
22,590  
(23.9)  
TC :Total Cooling Capacity (BTU/h)  
SHC:Sensible Heat Capacity (BTU/h)  
CI :Compressor Input (kW)  
Rating conditions are  
:Outdoor Ambient Temp.95° FDB  
:Indoor Unit Entering Air Temp.80° FDB/67° FWB  
SM830082  
I - 61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor Unit: TH4242 Outdoor Unit: CH4242  
• 208V / 1 phase / 60Hz  
RATING CAPACITY :  
EVAPORATOR  
40,000 BTU/h  
AIR FLOW RATE:  
CONDENSER  
800 CFM  
ENT.TEMP.°F(°C)  
AMBIENT TEMP °F(°C)  
WB  
DB  
75  
85  
95  
105  
115  
(23.9)  
40,520  
2.91  
(29.4)  
(35.0)  
36,320  
3.46  
(40.6)  
(46.1)  
TC  
CI  
38,560  
3.18  
33,800  
4.16  
31,000  
4.86  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
27,740  
30,610  
33,600  
36,470  
39,340  
42,040  
2.94  
26,610  
29,480  
32,480  
35,350  
38,210  
40,160  
3.22  
25,360  
28,230  
31,230  
34,090  
36,320  
38,160  
3.51  
23,990  
26,860  
29,860  
32,730  
33,800  
35,880  
4.22  
22,520  
25,390  
28,390  
31,000  
31,000  
33,400  
4.93  
59  
(15.0)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
23,960  
26,820  
29,820  
32,690  
35,560  
43,640  
2.96  
22,960  
25,830  
28,830  
31,700  
34,560  
41,920  
3.25  
21,940  
24,800  
27,800  
30,670  
33,540  
# 40,000  
3.55  
20,790  
23,660  
26,660  
29,520  
32,390  
37,880  
4.27  
19,580  
22,450  
25,450  
28,320  
31,180  
35,560  
4.98  
63  
(17.2)  
1
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
20,150  
23,020  
26,010  
28,880  
31,750  
45,960  
3
19,320  
22,190  
25,190  
28,050  
30,920  
44,360  
3.28  
18,410  
21,280  
24,280  
27,150  
30,010  
42,640  
3.6  
17,440  
20,300  
23,300  
26,170  
29,040  
40,760  
4.33  
16,400  
19,260  
22,260  
25,130  
28,000  
38,680  
5.05  
67  
(19.4)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
16,430  
19,300  
22,300  
25,160  
28,030  
46,880  
3.05  
15,730  
18,600  
21,590  
24,460  
27,330  
45,360  
3.34  
14,990  
17,850  
20,850  
23,720  
26,590  
43,760  
3.66  
14,190  
17,060  
20,060  
22,920  
25,790  
41,920  
4.39  
13,330  
16,200  
19,200  
22,060  
24,930  
39,960  
5.13  
71  
(21.7)  
CI  
75  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
15,100  
18,100  
20,970  
23,840  
14,510  
17,500  
20,370  
23,240  
13,890  
16,880  
19,750  
22,620  
13,190  
16,180  
19,050  
21,920  
12,450  
15,450  
18,320  
21,190  
(23.9)  
TC :Total Cooling Capacity (BTU/h)  
SHC:Sensible Heat Capacity (BTU/h)  
CI :Compressor Input (kW)  
Rating conditions are  
:Outdoor Ambient Temp.95° FDB  
:Indoor Unit Entering Air Temp.80° FDB/67° FWB  
SM830082  
I - 62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor Unit: UH2442 Outdoor Unit: CH2442  
• 230V / 1 phase / 60Hz  
RATING CAPACITY :  
EVAPORATOR  
24,000 BTU/h  
AIR FLOW RATE:  
CONDENSER  
670 CFM  
ENT.TEMP.°F(°C)  
AMBIENT TEMP °F(°C)  
WB  
DB  
75  
85  
95  
105  
115  
(23.9)  
24,310  
1.71  
(29.4)  
(35.0)  
21,790  
2.03  
(40.6)  
(46.1)  
TC  
CI  
23,140  
1.86  
20,280  
2.26  
18,600  
2.49  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
16,820  
18,720  
20,710  
22,610  
24,310  
25,220  
1.72  
16,180  
18,080  
20,070  
21,970  
23,140  
24,100  
1.89  
15,450  
17,350  
19,340  
21,240  
21,790  
22,900  
2.06  
14,660  
16,560  
18,550  
20,280  
20,280  
21,530  
2.29  
13,810  
15,710  
17,700  
18,600  
18,600  
20,040  
2.52  
59  
(15.0)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
14,370  
16,270  
18,260  
20,160  
22,060  
26,180  
1.74  
13,810  
15,710  
17,690  
19,600  
21,500  
25,150  
1.9  
13,210  
15,110  
17,100  
19,000  
20,900  
# 24,000  
2.08  
12,550  
14,450  
16,440  
18,340  
20,240  
22,730  
2.32  
11,850  
13,750  
15,740  
17,640  
19,540  
21,340  
2.55  
63  
(17.2)  
1
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
11,910  
13,810  
15,800  
17,700  
19,600  
27,580  
1.76  
11,430  
13,330  
15,320  
17,220  
19,120  
26,620  
1.92  
10,910  
12,810  
14,800  
16,700  
18,600  
25,580  
2.11  
10,350  
12,250  
14,240  
16,140  
18,040  
24,460  
2.35  
9,750  
67  
11,650  
13,630  
15,530  
17,430  
23,210  
2.59  
(19.4)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
9,490  
9,090  
8,660  
8,200  
7,700  
71  
11,390  
13,380  
15,280  
17,180  
28,130  
1.79  
10,990  
12,970  
14,870  
16,780  
27,220  
1.96  
10,560  
12,540  
14,440  
16,340  
26,260  
2.14  
10,100  
12,090  
13,990  
15,890  
25,150  
2.38  
9,600  
(21.7)  
11,590  
13,490  
15,390  
23,980  
2.63  
CI  
75  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
8,710  
8,360  
8,000  
7,600  
7,180  
(23.9)  
10,690  
12,590  
14,490  
10,350  
12,250  
14,150  
9,990  
9,590  
9,160  
11,890  
13,790  
11,490  
13,390  
11,070  
12,970  
TC :Total Cooling Capacity (BTU/h)  
SHC:Sensible Heat Capacity (BTU/h)  
CI :Compressor Input (kW)  
Rating conditions are  
:Outdoor Ambient Temp.95° FDB  
:Indoor Unit Entering Air Temp.80° FDB/67° FWB  
SM830082  
I - 63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor Unit: UH2442 Outdoor Unit: CH2442  
• 208V / 1 phase / 60Hz  
RATING CAPACITY :  
EVAPORATOR  
23,400 BTU/h  
AIR FLOW RATE:  
CONDENSER  
600 CFM  
ENT.TEMP.°F(°C)  
AMBIENT TEMP °F(°C)  
WB  
DB  
75  
85  
95  
105  
115  
(23.9)  
23,700  
1.75  
(29.4)  
(35.0)  
21,250  
2.09  
(40.6)  
(46.1)  
TC  
CI  
22,560  
1.92  
19,770  
2.33  
18,140  
2.56  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
16,860  
18,930  
21,090  
23,150  
23,700  
24,590  
1.77  
16,260  
18,330  
20,490  
22,560  
22,560  
23,490  
1.94  
15,590  
17,660  
19,820  
21,250  
21,250  
22,320  
2.12  
14,850  
16,910  
19,070  
19,770  
19,770  
20,990  
2.36  
14,050  
16,120  
18,140  
18,140  
18,140  
19,540  
2.6  
59  
(15.0)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
14,280  
16,340  
18,500  
20,570  
22,630  
25,530  
1.79  
13,750  
15,810  
17,970  
20,040  
22,100  
24,520  
1.96  
13,190  
15,260  
17,420  
19,490  
21,550  
# 23,400  
2.14  
12,580  
14,640  
16,800  
18,870  
20,940  
22,160  
2.39  
11,920  
13,990  
16,150  
18,210  
19,540  
20,800  
2.63  
63  
(17.2)  
1
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
11,680  
13,740  
15,900  
17,970  
20,040  
26,890  
1.81  
11,230  
13,300  
15,460  
17,530  
19,590  
25,950  
1.98  
10,750  
12,810  
14,970  
17,040  
19,110  
24,940  
2.17  
10,220  
12,290  
14,450  
16,510  
18,580  
23,840  
2.42  
9,660  
67  
11,720  
13,880  
15,950  
18,010  
22,630  
2.67  
(19.4)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
9,110  
8,730  
8,330  
7,900  
7,440  
71  
11,170  
13,330  
15,400  
17,460  
27,420  
1.84  
10,800  
12,960  
15,020  
17,090  
26,540  
2.01  
10,400  
12,560  
14,620  
16,690  
25,600  
2.2  
9,970  
9,500  
(21.7)  
12,130  
14,190  
16,260  
24,520  
2.46  
11,660  
13,730  
15,800  
23,380  
2.71  
CI  
75  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
8,360  
8,050  
7,710  
7,330  
6,940  
(23.9)  
10,520  
12,590  
14,660  
10,210  
12,270  
14,340  
9,870  
9,490  
9,100  
11,940  
14,000  
11,560  
13,630  
11,170  
13,230  
TC :Total Cooling Capacity (BTU/h)  
SHC:Sensible Heat Capacity (BTU/h)  
CI :Compressor Input (kW)  
Rating conditions are  
:Outdoor Ambient Temp.95° FDB  
:Indoor Unit Entering Air Temp.80° FDB/67° FWB  
SM830082  
I - 64  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor Unit: UH3642 Outdoor Unit: CH3642  
• 230V / 1 phase / 60Hz  
RATING CAPACITY :  
EVAPORATOR  
34,500 BTU/h  
AIR FLOW RATE:  
CONDENSER  
1,060 CFM  
ENT.TEMP.°F(°C)  
AMBIENT TEMP °F(°C)  
WB  
DB  
75  
85  
95  
105  
115  
(23.9)  
34,950  
2.32  
(29.4)  
(35.0)  
31,330  
2.76  
(40.6)  
(46.1)  
TC  
CI  
33,260  
2.53  
29,150  
3.06  
26,740  
3.36  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
26,210  
29,810  
33,570  
34,950  
34,950  
36,260  
2.34  
25,370  
28,970  
32,740  
33,260  
33,260  
34,640  
2.57  
24,440  
28,040  
31,330  
31,330  
31,330  
32,910  
2.8  
23,400  
27,000  
29,150  
29,150  
29,150  
30,950  
3.11  
22,280  
25,880  
26,740  
26,740  
26,740  
28,810  
3.42  
59  
(15.0)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
21,860  
25,460  
29,230  
32,830  
36,260  
37,640  
2.36  
21,130  
24,730  
28,490  
32,090  
34,640  
36,160  
2.59  
20,360  
23,960  
27,720  
31,320  
32,910  
# 34,500  
2.83  
19,500  
23,100  
26,860  
30,460  
30,950  
32,670  
3.14  
18,580  
22,180  
25,940  
28,810  
28,810  
30,670  
3.45  
63  
(17.2)  
1
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
17,500  
21,100  
24,860  
28,460  
32,060  
39,640  
2.39  
16,890  
20,490  
24,250  
27,850  
31,450  
38,260  
2.62  
16,210  
19,810  
23,570  
27,170  
30,770  
36,780  
2.87  
15,470  
19,070  
22,840  
26,440  
30,040  
35,160  
3.19  
14,680  
18,280  
22,050  
25,650  
29,250  
33,360  
3.5  
67  
(19.4)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
13,150  
16,750  
20,510  
24,110  
27,710  
40,430  
2.43  
12,620  
16,220  
19,990  
23,590  
27,190  
39,120  
2.66  
12,070  
15,670  
19,440  
23,040  
26,640  
37,740  
2.91  
11,480  
15,080  
18,840  
22,440  
26,040  
36,160  
3.23  
10,820  
14,420  
18,190  
21,790  
25,390  
34,470  
3.55  
71  
(21.7)  
CI  
75  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
12,100  
15,860  
19,460  
23,060  
11,650  
15,420  
19,020  
22,620  
11,190  
14,950  
18,550  
22,150  
10,660  
14,430  
18,030  
21,630  
10,110  
13,870  
17,470  
21,070  
(23.9)  
TC :Total Cooling Capacity (BTU/h)  
SHC:Sensible Heat Capacity (BTU/h)  
CI :Compressor Input (kW)  
Rating conditions are  
:Outdoor Ambient Temp.95° FDB  
:Indoor Unit Entering Air Temp.80° FDB/67° FWB  
SM830082  
I - 65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor Unit: UH3642 Outdoor Unit: CH3642  
• 208V / 1 phase / 60Hz  
RATING CAPACITY :  
EVAPORATOR  
33,000 BTU/h  
AIR FLOW RATE:  
CONDENSER  
950 CFM  
ENT.TEMP.°F(°C)  
AMBIENT TEMP °F(°C)  
WB  
DB  
75  
85  
95  
105  
115  
(23.9)  
33,430  
2.21  
(29.4)  
(35.0)  
29,960  
2.62  
(40.6)  
(46.1)  
TC  
CI  
31,810  
2.41  
27,890  
2.96  
25,580  
3.3  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
24,700  
27,990  
31,420  
33,430  
33,430  
34,680  
2.23  
23,890  
27,180  
30,610  
31,810  
31,810  
33,130  
2.44  
22,980  
26,270  
29,700  
29,960  
29,960  
31,480  
2.66  
21,980  
25,270  
27,890  
27,890  
27,890  
29,600  
3
20,890  
24,180  
25,580  
25,580  
25,580  
27,560  
3.35  
59  
(15.0)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
20,700  
23,980  
27,420  
30,710  
34,000  
36,000  
2.25  
19,980  
23,270  
26,710  
30,000  
33,130  
34,580  
2.46  
19,240  
22,530  
25,960  
29,250  
31,480  
# 33,000  
2.69  
18,400  
21,690  
25,130  
28,410  
29,600  
31,250  
3.04  
17,510  
20,800  
24,240  
27,520  
27,560  
29,340  
3.38  
63  
(17.2)  
1
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
16,680  
19,960  
23,400  
26,690  
29,980  
37,920  
2.27  
16,080  
19,370  
22,800  
26,090  
29,380  
36,600  
2.49  
15,420  
18,710  
22,150  
25,440  
28,720  
35,180  
2.73  
14,710  
18,000  
21,440  
24,720  
28,010  
33,630  
3.08  
13,950  
17,230  
20,670  
23,960  
27,240  
31,910  
3.43  
67  
(19.4)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
12,670  
15,960  
19,400  
22,690  
25,970  
38,680  
2.31  
12,170  
15,460  
18,890  
22,180  
25,470  
37,420  
2.53  
11,630  
14,920  
18,360  
21,640  
24,930  
36,100  
2.77  
11,050  
14,340  
17,780  
21,060  
24,350  
34,580  
3.13  
10,420  
13,710  
17,150  
20,430  
23,720  
32,970  
3.48  
71  
(21.7)  
CI  
75  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
11,670  
15,100  
18,390  
21,680  
11,230  
14,670  
17,960  
21,240  
10,780  
14,220  
17,510  
20,790  
10,270  
13,710  
16,990  
20,280  
9,740  
(23.9)  
13,170  
16,460  
19,750  
TC :Total Cooling Capacity (BTU/h)  
SHC:Sensible Heat Capacity (BTU/h)  
CI :Compressor Input (kW)  
Rating conditions are  
:Outdoor Ambient Temp.95° FDB  
:Indoor Unit Entering Air Temp.80° FDB/67° FWB  
SM830082  
I - 66  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor Unit: KH2442 Outdoor Unit: CH2442  
• 230V / 1 phase / 60Hz  
RATING CAPACITY :  
EVAPORATOR  
22,000 BTU/h  
AIR FLOW RATE:  
CONDENSER  
540 CFM  
ENT.TEMP.°F(°C)  
AMBIENT TEMP °F(°C)  
WB  
DB  
75  
85  
95  
105  
115  
(23.9)  
22,290  
1.71  
(29.4)  
(35.0)  
19,980  
2.03  
(40.6)  
(46.1)  
TC  
CI  
21,210  
1.86  
18,590  
2.26  
17,050  
2.49  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
15,990  
17,950  
20,000  
21,960  
22,290  
23,120  
1.72  
15,430  
17,390  
19,440  
21,210  
21,210  
22,090  
1.89  
14,800  
16,760  
18,810  
19,980  
19,980  
20,990  
2.06  
14,110  
16,070  
18,120  
18,590  
18,590  
19,730  
2.29  
13,360  
15,330  
17,050  
17,050  
17,050  
18,370  
2.52  
59  
(15.0)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
13,550  
15,510  
17,560  
19,520  
21,480  
24,000  
1.74  
13,060  
15,020  
17,070  
19,030  
20,990  
23,060  
1.9  
12,540  
14,500  
16,550  
18,510  
20,470  
# 22,000  
2.08  
11,960  
13,920  
15,970  
17,930  
19,730  
20,830  
2.32  
11,350  
13,310  
15,360  
17,320  
18,370  
19,560  
2.55  
63  
(17.2)  
1
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
11,100  
13,060  
15,110  
17,070  
19,030  
25,280  
1.76  
10,690  
12,650  
14,700  
16,660  
18,620  
24,400  
1.92  
10,230  
12,190  
14,240  
16,200  
18,160  
23,450  
2.11  
9,740  
9,210  
67  
11,700  
13,750  
15,710  
17,670  
22,420  
2.35  
11,170  
13,220  
15,180  
17,140  
21,270  
2.59  
(19.4)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
8,670  
8,320  
7,950  
7,550  
7,110  
71  
10,630  
12,680  
14,640  
16,600  
25,780  
1.79  
10,280  
12,330  
14,290  
16,250  
24,950  
1.96  
9,910  
9,510  
9,070  
(21.7)  
11,960  
13,920  
15,880  
24,070  
2.14  
11,560  
13,520  
15,480  
23,060  
2.38  
11,120  
13,080  
15,040  
21,980  
2.63  
CI  
75  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
7,980  
7,690  
7,380  
7,020  
6,650  
(23.9)  
10,030  
11,990  
13,960  
9,740  
9,430  
9,070  
8,700  
11,700  
13,660  
11,390  
13,350  
11,030  
12,990  
10,660  
12,620  
TC :Total Cooling Capacity (BTU/h)  
SHC:Sensible Heat Capacity (BTU/h)  
CI :Compressor Input (kW)  
Rating conditions are  
:Outdoor Ambient Temp.95° FDB  
:Indoor Unit Entering Air Temp.80° FDB/67° FWB  
SM830082  
I - 67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor Unit: KH2442 Outdoor Unit: CH2442  
• 208V / 1 phase / 60Hz  
RATING CAPACITY :  
EVAPORATOR  
21,000 BTU/h  
AIR FLOW RATE:  
CONDENSER  
510 CFM  
ENT.TEMP.°F(°C)  
AMBIENT TEMP °F(°C)  
WB  
DB  
75  
85  
95  
105  
115  
(23.9)  
21,270  
1.75  
(29.4)  
(35.0)  
19,070  
2.09  
(40.6)  
(46.1)  
TC  
CI  
20,240  
1.92  
17,750  
2.33  
16,280  
2.56  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
15,260  
17,130  
19,080  
20,950  
21,270  
22,070  
1.77  
14,730  
16,590  
18,550  
20,240  
20,240  
21,080  
1.94  
14,130  
16,000  
17,950  
19,070  
19,070  
20,030  
2.12  
13,470  
15,340  
17,290  
17,750  
17,750  
18,840  
2.36  
12,760  
14,620  
16,280  
16,280  
16,280  
17,540  
2.6  
59  
(15.0)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
12,940  
14,810  
16,760  
18,630  
20,490  
22,910  
1.79  
12,470  
14,330  
16,290  
18,150  
20,020  
22,010  
1.96  
11,970  
13,840  
15,790  
17,660  
19,530  
# 21,000  
2.14  
11,430  
13,290  
15,250  
17,110  
18,840  
19,890  
2.39  
10,840  
12,710  
14,660  
16,530  
17,540  
18,670  
2.63  
63  
(17.2)  
1
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
10,600  
12,470  
14,420  
16,290  
18,160  
24,130  
1.81  
10,210  
12,080  
14,030  
15,900  
17,760  
23,290  
1.98  
9,780  
9,310  
8,800  
67  
11,640  
13,590  
15,460  
17,330  
22,390  
2.17  
11,170  
13,130  
14,990  
16,860  
21,400  
2.42  
10,670  
12,620  
14,490  
16,360  
20,310  
2.67  
(19.4)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
8,290  
7,960  
7,600  
7,220  
6,800  
71  
10,160  
12,110  
13,980  
15,840  
24,610  
1.84  
9,820  
9,470  
9,090  
8,670  
(21.7)  
11,780  
13,640  
15,510  
23,810  
2.01  
11,420  
13,290  
15,160  
22,970  
2.2  
11,040  
12,910  
14,770  
22,010  
2.46  
10,620  
12,490  
14,360  
20,980  
2.71  
CI  
75  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
7,640  
7,350  
7,050  
6,720  
6,360  
(23.9)  
9,590  
9,300  
9,010  
8,670  
8,320  
11,460  
13,320  
11,170  
13,040  
10,870  
12,740  
10,540  
12,400  
10,180  
12,050  
TC :Total Cooling Capacity (BTU/h)  
SHC:Sensible Heat Capacity (BTU/h)  
CI :Compressor Input (kW)  
Rating conditions are  
:Outdoor Ambient Temp.95° FDB  
:Indoor Unit Entering Air Temp.80° FDB/67° FWB  
SM830082  
I - 68  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor Unit: KH3642 Outdoor Unit: CH3642  
• 230V / 1 phase / 60Hz  
RATING CAPACITY :  
EVAPORATOR  
33,000 BTU/h  
AIR FLOW RATE:  
CONDENSER  
830 CFM  
ENT.TEMP.°F(°C)  
AMBIENT TEMP °F(°C)  
WB  
DB  
75  
85  
95  
105  
115  
(23.9)  
33,430  
2.32  
(29.4)  
(35.0)  
29,960  
2.76  
(40.6)  
(46.1)  
TC  
CI  
31,810  
2.53  
27,890  
3.06  
25,580  
3.36  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
23,980  
26,900  
29,960  
32,880  
33,430  
34,680  
2.34  
23,130  
26,060  
29,110  
31,810  
31,810  
33,130  
2.57  
22,190  
25,110  
28,170  
29,960  
29,960  
31,480  
2.8  
21,160  
24,080  
27,130  
27,890  
27,890  
29,600  
3.11  
20,030  
22,960  
25,580  
25,580  
25,580  
27,560  
3.42  
59  
(15.0)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
20,340  
23,260  
26,320  
29,240  
32,160  
36,000  
2.36  
19,600  
22,520  
25,570  
28,500  
31,420  
34,580  
2.59  
18,820  
21,740  
24,800  
27,720  
30,640  
# 33,000  
2.83  
17,960  
20,880  
23,930  
26,850  
29,600  
31,250  
3.14  
17,040  
19,960  
23,010  
25,940  
27,560  
29,340  
3.45  
63  
(17.2)  
1
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
16,680  
19,600  
22,660  
25,580  
28,500  
37,920  
2.39  
16,060  
18,980  
22,040  
24,960  
27,880  
36,600  
2.62  
15,380  
18,300  
21,360  
24,280  
27,200  
35,180  
2.87  
14,640  
17,560  
20,620  
23,540  
26,460  
33,630  
3.19  
13,850  
16,770  
19,820  
22,750  
25,670  
31,910  
3.5  
67  
(19.4)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
13,060  
15,980  
19,040  
21,960  
24,880  
38,680  
2.43  
12,540  
15,460  
18,510  
21,430  
24,360  
37,420  
2.66  
11,980  
14,900  
17,950  
20,880  
23,800  
36,100  
2.91  
11,380  
14,300  
17,350  
20,280  
23,200  
34,580  
3.23  
10,720  
13,640  
16,700  
19,620  
22,540  
32,970  
3.55  
71  
(21.7)  
CI  
75  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
12,040  
15,090  
18,010  
20,940  
11,590  
14,640  
17,560  
20,480  
11,120  
14,170  
17,090  
20,020  
10,590  
13,640  
16,560  
19,490  
10,030  
13,090  
16,010  
18,930  
(23.9)  
TC :Total Cooling Capacity (BTU/h)  
SHC:Sensible Heat Capacity (BTU/h)  
CI :Compressor Input (kW)  
Rating conditions are  
:Outdoor Ambient Temp.95° FDB  
:Indoor Unit Entering Air Temp.80° FDB/67° FWB  
SM830082  
I - 69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor Unit: KH3642 Outdoor Unit: CH3642  
• 208V / 1 phase / 60Hz  
RATING CAPACITY :  
EVAPORATOR  
32,000 BTU/h  
AIR FLOW RATE:  
CONDENSER  
750 CFM  
ENT.TEMP.°F(°C)  
AMBIENT TEMP °F(°C)  
WB  
DB  
75  
85  
95  
105  
115  
(23.9)  
32,420  
2.21  
(29.4)  
(35.0)  
29,060  
2.62  
(40.6)  
(46.1)  
TC  
CI  
30,850  
2.41  
27,040  
2.96  
24,800  
3.3  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
22,940  
25,620  
28,420  
31,100  
32,420  
33,630  
2.23  
22,100  
24,780  
27,580  
30,270  
30,850  
32,130  
2.44  
21,170  
23,850  
26,650  
29,060  
29,060  
30,530  
2.66  
20,140  
22,820  
25,620  
27,040  
27,040  
28,700  
3
19,030  
21,710  
24,520  
24,800  
24,800  
26,720  
3.35  
59  
(15.0)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
19,550  
22,230  
25,040  
27,720  
30,400  
34,910  
2.25  
18,820  
21,500  
24,300  
26,980  
29,660  
33,540  
2.46  
18,050  
20,730  
23,530  
26,220  
28,900  
# 32,000  
2.69  
17,190  
19,870  
22,670  
25,360  
28,040  
30,300  
3.04  
16,280  
18,960  
21,770  
24,450  
26,720  
28,450  
3.38  
63  
(17.2)  
1
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
16,150  
18,830  
21,630  
24,320  
27,000  
36,770  
2.27  
15,530  
18,220  
21,020  
23,700  
26,380  
35,490  
2.49  
14,860  
17,540  
20,340  
23,020  
25,710  
34,110  
2.73  
14,120  
16,810  
19,610  
22,290  
24,970  
32,610  
3.08  
13,340  
16,020  
18,830  
21,510  
24,190  
30,940  
3.43  
67  
(19.4)  
CI  
72(22.2)  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
TC  
12,790  
15,470  
18,280  
20,960  
23,640  
37,500  
2.31  
12,270  
14,950  
17,750  
20,440  
23,120  
36,290  
2.53  
11,710  
14,400  
17,200  
19,880  
22,560  
35,010  
2.77  
11,120  
13,800  
16,610  
19,290  
21,970  
33,540  
3.13  
10,470  
13,160  
15,960  
18,640  
21,320  
31,970  
3.48  
71  
(21.7)  
CI  
75  
76(24.4)  
80(26.7)  
84(28.9)  
88(31.1)  
SHC  
SHC  
SHC  
SHC  
11,780  
14,580  
17,270  
19,950  
11,340  
14,140  
16,820  
19,500  
10,870  
13,680  
16,360  
19,040  
10,350  
13,150  
15,840  
18,520  
9,800  
(23.9)  
12,600  
15,290  
17,970  
TC :Total Cooling Capacity (BTU/h)  
SHC:Sensible Heat Capacity (BTU/h)  
CI :Compressor Input (kW)  
Rating conditions are  
:Outdoor Ambient Temp.95° FDB  
:Indoor Unit Entering Air Temp.80° FDB/67° FWB  
SM830082  
I - 70  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-8 Heating Capacity  
Indoor entering air temperature: 70°F  
120  
100  
80  
1
60  
10  
20  
30  
40  
50  
60  
Outdoor ambient temp. (°F DB at 75% RH)  
2182_X_S  
SM830082  
I - 71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-9 Performance Charts  
Cooling Characteristics  
(1) Operating Current  
1 Indoor Unit: XH2442  
Outdoor Unit: CH2442  
Operating current characteristics versus outdoor ambient temperature and indoor temperature.  
(Indoor relative humidity: 50%, Indoor fan speed: High)  
230V  
208V  
Outdoor fan speed  
Low High  
Outdoor fan speed  
Low High  
15  
14  
13  
12  
11  
10  
9
Indoor  
temp.  
°F (°C)  
15  
14  
13  
12  
11  
10  
9
Indoor  
temp.  
°F (°C)  
85 (30)  
85 (30)  
80 (27)  
75 (24)  
70 (21)  
80 (27)  
75 (24)  
70 (21)  
1
8
8
59  
(15)  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
59  
(15)  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
Outdoor ambient temp. °F (°C)  
Outdoor ambient temp. °F (°C)  
2183_X_S  
2184_X_S  
Indoor Unit: XH3642  
Outdoor Unit: CH3642  
230V  
208V  
Outdoor fan speed  
Low High  
Indoor  
temp.  
°F (°C)  
Outdoor fan speed  
Indoor  
temp.  
°F (°C)  
Low  
High  
19  
18  
17  
16  
15  
14  
13  
12  
19  
18  
17  
16  
15  
14  
13  
12  
85 (30)  
85 (30)  
80 (27)  
75 (24)  
70 (21)  
80 (27)  
75 (24)  
70 (21)  
59  
(15)  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
59  
(15)  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
Outdoor ambient temp. °F (°C)  
Outdoor ambient temp. °F (°C)  
1467_X_S  
2185_X_S  
SM830082  
I - 72  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-9 Performance Charts  
Cooling Characteristics  
(1) Operating Current  
1 Indoor Unit: XH4242  
Outdoor Unit: CH4242  
Operating current characteristics versus outdoor ambient temperature and indoor temperature.  
(Indoor relative humidity: 50%, Indoor fan speed: High)  
230V  
208V  
Outdoor fan speed  
Low High  
Indoor  
temp.  
Outdoor fan speed  
High  
Indoor  
temp.  
Low  
°F (°C)  
°F (°C)  
24  
23  
22  
21  
20  
19  
18  
17  
24  
23  
22  
21  
20  
19  
18  
17  
85 (30)  
80 (27)  
75 (24)  
70 (21)  
85 (30)  
80 (27)  
75 (24)  
70 (21)  
1
59  
(15)  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
59  
(15)  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
Outdoor ambient temp. °F (°C)  
Outdoor ambient temp. °F (°C)  
2223_X_S  
2224_X_S  
SM830082  
I - 73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-9 Performance Charts  
Cooling Characteristics  
(1) Operating Current  
1 Indoor Unit: TH2442  
Outdoor Unit: CH2442  
Operating current characteristics versus outdoor ambient temperature and indoor temperature.  
(Indoor relative humidity: 50%, Indoor fan speed: High)  
230V  
208V  
Outdoor fan speed  
Low High  
Outdoor fan speed  
Low High  
15  
14  
13  
12  
11  
10  
9
Indoor  
temp.  
°F (°C)  
15  
14  
13  
12  
11  
10  
9
Indoor  
temp.  
°F (°C)  
85 (30)  
80 (27)  
75 (24)  
70 (21)  
85 (30)  
80 (27)  
75 (24)  
70 (21)  
1
8
8
59  
(15)  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
59  
(15)  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
Outdoor ambient temp. °F (°C)  
Outdoor ambient temp. °F (°C)  
2187_X_S  
2186_X_S  
Indoor Unit: TH3642  
Outdoor Unit: CH3642  
230V  
208V  
Outdoor fan speed  
Indoor  
temp.  
°F (°C)  
Outdoor fan speed  
Low High  
Indoor  
temp.  
°F (°C)  
Low  
High  
19  
18  
17  
16  
15  
14  
13  
12  
19  
18  
17  
16  
15  
14  
13  
12  
85 (30)  
80 (27)  
75 (24)  
70 (21)  
85 (30)  
80 (27)  
75 (24)  
70 (21)  
59  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
59  
(15)  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
(15)  
Outdoor ambient temp. °F (°C)  
Outdoor ambient temp. °F (°C)  
1466_X_S  
1467_X_S  
SM830082  
I - 74  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-9 Performance Charts  
Cooling Characteristics  
(1) Operating Current  
1 Indoor Unit: TH4242  
Outdoor Unit: CH4242  
Operating current characteristics versus outdoor ambient temperature and indoor temperature.  
(Indoor relative humidity: 50%, Indoor fan speed: High)  
230V  
208V  
Outdoor fan speed  
Low High  
Indoor  
temp.  
Outdoor fan speed  
High  
Indoor  
temp.  
Low  
°F (°C)  
°F (°C)  
24  
23  
22  
21  
20  
19  
18  
17  
24  
23  
22  
21  
20  
19  
18  
17  
85 (30)  
80 (27)  
75 (24)  
70 (21)  
85 (30)  
80 (27)  
75 (24)  
70 (21)  
1
59  
(15)  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
59  
(15)  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
Outdoor ambient temp. °F (°C)  
Outdoor ambient temp. °F (°C)  
2223_X_S  
2224_X_S  
SM830082  
I - 75  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-9 Performance Charts  
Cooling Characteristics  
(1) Operating Current  
1 Indoor Unit: UH2442  
Outdoor Unit: CH2442  
Operating current characteristics versus outdoor ambient temperature and indoor temperature.  
(Indoor relative humidity: 50%, Indoor fan speed: High)  
230V  
208V  
Outdoor fan speed  
Low High  
Outdoor fan speed  
Low High  
Indoor  
temp.  
°F (°C)  
85 (30)  
80 (27)  
75 (24)  
70 (21)  
15  
14  
13  
12  
11  
10  
9
Indoor  
temp.  
15  
14  
13  
12  
11  
10  
9
°F (°C)  
85 (30)  
80 (27)  
75 (24)  
70 (21)  
1
8
8
59  
(15)  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
59  
(15)  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
Outdoor ambient temp. °F (°C)  
Outdoor ambient temp. °F (°C)  
2188_X_S  
2189_X_S  
Indoor Unit: UH3642  
Outdoor Unit: CH3642  
230V  
208V  
Outdoor fan speed  
Indoor  
temp.  
°F (°C)  
Outdoor fan speed  
Low High  
Indoor  
temp.  
°F (°C)  
Low  
High  
19  
18  
17  
16  
15  
14  
13  
12  
19  
18  
17  
16  
15  
14  
13  
12  
85 (30)  
80 (27)  
75 (24)  
70 (21)  
85 (30)  
80 (27)  
75 (24)  
70 (21)  
59  
(15)  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
59  
(15)  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
Outdoor ambient temp. °F (°C)  
Outdoor ambient temp. °F (°C)  
1466_X_S  
1467_X_S  
SM830082  
I - 76  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-9 Performance Charts  
Cooling Characteristics  
(1) Operating Current  
1 Indoor Unit: KH2442  
Outdoor Unit: CH2442  
Operating current characteristics versus outdoor ambient temperature and indoor temperature.  
(Indoor relative humidity: 50%, Indoor fan speed: High)  
230V  
208V  
Outdoor fan speed  
Low High  
Outdoor fan speed  
Low High  
15  
14  
13  
12  
11  
10  
9
Indoor  
temp.  
°F (°C)  
15  
14  
13  
12  
11  
10  
9
Indoor  
temp.  
°F (°C)  
85 (30)  
80 (27)  
75 (24)  
70 (21)  
85 (30)  
80 (27)  
75 (24)  
70 (21)  
1
8
8
59  
(15)  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
59  
(15)  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
Outdoor ambient temp. °F (°C)  
Outdoor ambient temp. °F (°C)  
1159_X_S  
1160_X_S  
Indoor Unit: KH3642  
Outdoor Unit: CH3642  
230V  
208V  
Outdoor fan speed  
Indoor  
temp.  
°F (°C)  
Outdoor fan speed  
Low High  
Indoor  
temp.  
°F (°C)  
Low  
High  
19  
18  
17  
16  
15  
14  
13  
12  
19  
18  
17  
16  
15  
14  
13  
12  
85 (30)  
80 (27)  
75 (24)  
70 (21)  
85 (30)  
80 (27)  
75 (24)  
70 (21)  
59  
(15)  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
59  
(15)  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
Outdoor ambient temp. °F (°C)  
Outdoor ambient temp. °F (°C)  
2190_X_S  
2191_X_S  
SM830082  
I - 77  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-9 Performance Charts  
Heating Characteristics  
(1) Operating Current  
1 Indoor Unit: XH2442  
Outdoor Unit: CH2442  
Operating current characteristics versus outdoor ambient temperature and indoor temperature.  
(Indoor relative humidity: 50%, Indoor fan speed: High)  
230V  
208V  
Indoor  
temp.  
°F (°C)  
75 (24)  
70 (21)  
65 (18)  
Indoor  
temp.  
°F (°C)  
75 (24)  
70 (21)  
65 (18)  
15  
14  
13  
12  
11  
10  
9
15  
14  
13  
12  
11  
10  
9
8
8
1
14  
(–10)  
23  
(–5)  
32  
( 0 )  
41  
( 5 )  
50  
(10)  
59  
(15)  
68  
(20)  
14  
(–10)  
23  
(–5)  
32  
( 0 )  
41  
( 5 )  
50  
(10)  
59  
(15)  
68  
(20)  
Outdoor ambient temp. °F (°C)  
Outdoor ambient temp. °F (°C)  
2232_X_S  
2192_X_S  
Indoor Unit: XH3642  
Outdoor Unit: CH3642  
230V  
208V  
Indoor  
temp.  
°F (°C)  
75 (24)  
70 (21)  
65 (18)  
Indoor  
temp.  
°F (°C)  
75 (24)  
70 (21)  
65 (18)  
22  
21  
20  
19  
18  
17  
16  
15  
22  
21  
20  
19  
18  
17  
16  
15  
14  
(–10)  
23  
(–5)  
32  
( 0 )  
41  
( 5 )  
50  
(10)  
59  
(15)  
68  
(20)  
14  
(–10)  
23  
(–5)  
32  
( 0 )  
41  
( 5 )  
50  
(10)  
59  
(15)  
68  
(20)  
Outdoor ambient temp. °F (°C)  
Outdoor ambient temp. °F (°C)  
2234_X_S  
2233_X_S  
SM830082  
I - 78  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-9 Performance Charts  
Heating Characteristics  
(1) Operating Current  
1 Indoor Unit: XH4242  
Outdoor Unit: CH4242  
Operating current characteristics versus outdoor ambient temperature and indoor temperature.  
(Indoor relative humidity: 50%, Indoor fan speed: High)  
230V  
208V  
Indoor  
Indoor  
temp.  
°F (°C)  
75 (24)  
70 (21)  
65 (18)  
temp.  
°F (°C)  
75 (24)  
70 (21)  
65 (18)  
25  
24  
23  
22  
21  
20  
19  
18  
25  
24  
23  
22  
21  
20  
19  
18  
1
14  
(–10)  
23  
(–5)  
32  
( 0 )  
41  
( 5 )  
50  
(10)  
59  
(15)  
68  
(20)  
14  
(–10)  
23  
(–5)  
32  
( 0 )  
41  
( 5 )  
50  
(10)  
59  
(15)  
68  
(20)  
Outdoor ambient temp. °F (°C)  
Outdoor ambient temp. °F (°C)  
2226_X_S  
2225_X_S  
SM830082  
I - 79  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-9 Performance Charts  
Heating Characteristics  
(1) Operating Current  
1 Indoor Unit: TH2442  
Outdoor Unit: CH2442  
Operating current characteristics versus outdoor ambient temperature and indoor temperature.  
(Indoor relative humidity: 50%, Indoor fan speed: High)  
230V  
208V  
Indoor  
temp.  
°F (°C)  
75 (24)  
70 (21)  
65 (18)  
Indoor  
temp.  
°F (°C)  
75 (24)  
70 (21)  
65 (18)  
15  
14  
13  
12  
11  
10  
9
15  
14  
13  
12  
11  
10  
9
8
8
1
14  
(–10)  
23  
(–5)  
32  
( 0 )  
41  
( 5 )  
50  
(10)  
59  
(15)  
68  
(20)  
14  
(–10)  
23  
(–5)  
32  
( 0 )  
41  
( 5 )  
50  
(10)  
59  
(15)  
68  
(20)  
Outdoor ambient temp. °F (°C)  
Outdoor ambient temp. °F (°C)  
2192_X_S  
2193_X_S  
Indoor Unit: TH3642  
Outdoor Unit: CH3642  
230V  
208V  
Indoor  
temp.  
°F (°C)  
75 (24)  
70 (21)  
65 (18)  
Indoor  
temp.  
°F (°C)  
75 (24)  
70 (21)  
65 (18)  
22  
21  
20  
19  
18  
17  
16  
15  
22  
21  
20  
19  
18  
17  
16  
15  
14  
(–10)  
23  
(–5)  
32  
( 0 )  
41  
( 5 )  
50  
(10)  
59  
(15)  
68  
(20)  
14  
(–10)  
23  
(–5)  
32  
( 0 )  
41  
( 5 )  
50  
(10)  
59  
(15)  
68  
(20)  
Outdoor ambient temp. °F (°C)  
Outdoor ambient temp. °F (°C)  
2234_X_S  
2233_X_S  
SM830082  
I - 80  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-9 Performance Charts  
Heating Characteristics  
(1) Operating Current  
1 Indoor Unit: TH4242  
Outdoor Unit: CH4242  
Operating current characteristics versus outdoor ambient temperature and indoor temperature.  
(Indoor relative humidity: 50%, Indoor fan speed: High)  
230V  
208V  
Indoor  
temp.  
°F (°C)  
75 (24)  
70 (21)  
65 (18)  
Indoor  
temp.  
°F (°C)  
75 (24)  
70 (21)  
65 (18)  
25  
24  
23  
22  
21  
20  
19  
18  
25  
24  
23  
22  
21  
20  
19  
18  
1
14  
(–10)  
23  
(–5)  
32  
( 0 )  
41  
( 5 )  
50  
(10)  
59  
(15)  
68  
(20)  
14  
(–10)  
23  
(–5)  
32  
( 0 )  
41  
( 5 )  
50  
(10)  
59  
(15)  
68  
(20)  
Outdoor ambient temp. °F (°C)  
Outdoor ambient temp. °F (°C)  
2225_X_S  
2227_X_S  
SM830082  
I - 81  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-9 Performance Charts  
Heating Characteristics  
(1) Operating Current  
1 Indoor Unit: UH2442  
Outdoor Unit: CH2442  
Operating current characteristics versus outdoor ambient temperature and indoor temperature.  
(Indoor relative humidity: 50%, Indoor fan speed: High)  
230V  
208V  
Indoor  
temp.  
°F (°C)  
75 (24)  
70 (21)  
65 (18)  
Indoor  
temp.  
°F (°C)  
75 (24)  
70 (21)  
65 (18)  
15  
14  
13  
12  
11  
10  
9
15  
14  
13  
12  
11  
10  
9
8
8
1
14  
(–10)  
23  
(–5)  
32  
( 0 )  
41  
( 5 )  
50  
(10)  
59  
(15)  
68  
(20)  
14  
(–10)  
23  
(–5)  
32  
( 0 )  
41  
( 5 )  
50  
(10)  
59  
(15)  
68  
(20)  
Outdoor ambient temp. °F (°C)  
Outdoor ambient temp. °F (°C)  
2194_X_S  
2195_X_S  
Indoor Unit: UH3642  
Outdoor Unit: CH3642  
230V  
208V  
Indoor  
temp.  
°F (°C)  
75 (24)  
70 (21)  
65 (18)  
Indoor  
temp.  
°F (°C)  
75 (24)  
70 (21)  
65 (18)  
22  
21  
20  
19  
18  
17  
16  
15  
22  
21  
20  
19  
18  
17  
16  
15  
14  
(–10)  
23  
(–5)  
32  
( 0 )  
41  
( 5 )  
50  
(10)  
59  
(15)  
68  
(20)  
14  
(–10)  
23  
(–5)  
32  
( 0 )  
41  
( 5 )  
50  
(10)  
59  
(15)  
68  
(20)  
Outdoor ambient temp. °F (°C)  
Outdoor ambient temp. °F (°C)  
2234_X_S  
2233_X_S  
SM830082  
I - 82  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-9 Performance Charts  
Heating Characteristics  
(1) Operating Current  
1 Indoor Unit: KH2442  
Outdoor Unit: CH2442  
Operating current characteristics versus outdoor ambient temperature and indoor temperature.  
(Indoor relative humidity: 50%, Indoor fan speed: High)  
230V  
208V  
Indoor  
temp.  
°F (°C)  
75 (24)  
70 (21)  
65 (18)  
Indoor  
temp.  
°F (°C)  
75 (24)  
70 (21)  
65 (18)  
15  
14  
13  
12  
11  
10  
9
15  
14  
13  
12  
11  
10  
9
8
8
1
14  
(–10)  
23  
(–5)  
32  
( 0 )  
41  
( 5 )  
50  
(10)  
59  
(15)  
68  
(20)  
14  
(–10)  
23  
(–5)  
32  
( 0 )  
41  
( 5 )  
50  
(10)  
59  
(15)  
68  
(20)  
Outdoor ambient temp. °F (°C)  
Outdoor ambient temp. °F (°C)  
2232_X_S  
2235_X_S  
Indoor Unit: KH3642  
Outdoor Unit: CH3642  
230V  
208V  
Indoor  
temp.  
°F (°C)  
75 (24)  
70 (21)  
65 (18)  
Indoor  
temp.  
°F (°C)  
22  
21  
20  
19  
18  
17  
16  
15  
22  
21  
20  
19  
18  
17  
16  
15  
75 (24)  
70 (21)  
65 (18)  
14  
23  
(–5)  
32  
( 0 )  
41  
( 5 )  
50  
(10)  
59  
(15)  
68  
(20)  
14  
(–10)  
23  
(–5)  
32  
( 0 )  
41  
( 5 )  
50  
(10)  
59  
(15)  
68  
(20)  
(–10)  
Outdoor ambient temp. °F (°C)  
Outdoor ambient temp. °F (°C)  
2197_X_S  
2196_X_S  
SM830082  
I - 83  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-9 Performance Charts  
Cooling Characteristics  
(2) Operating Pressure  
1 Indoor Unit: 24 Type  
• High Pressure  
Outdoor Unit: CH2442  
High pressure characteristics versus outdoor ambient temperature and indoor temperature.  
(Indoor relative humidity: 50%, Indoor fan speed: High)  
230V / 208V  
Outdoor fan speed  
Low  
High  
340  
320  
300  
280  
260  
240  
220  
200  
180  
160  
Indoor  
temp.  
°F (°C)  
85 (30)  
80 (27)  
75 (24)  
70 (21)  
1
59  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
(15)  
Outdoor ambient temp. °F (°C)  
1161_X_S  
• Low Pressure  
Low pressure characteristics versus outdoor ambient temperature and indoor temperature.  
(Indoor relative humidity: 50%, Indoor fan speed: High)  
230V / 208V  
Outdoor fan speed  
Low  
High  
100  
90  
80  
70  
60  
50  
40  
Indoor  
temp.  
°F (°C)  
85 (30)  
80 (27)  
75 (24)  
70 (21)  
59  
(15)  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
Outdoor ambient temp. °F (°C)  
1162_X_S  
SM830082  
I - 84  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-9 Performance Charts  
Cooling Characteristics  
(2) Operating Pressure  
1 Indoor Unit: 36 Type  
• High Pressure  
Outdoor Unit: CH3642  
High pressure characteristics versus outdoor ambient temperature and indoor temperature.  
(Indoor relative humidity: 50%, Indoor fan speed: High)  
230V / 208V  
Outdoor fan speed  
Low  
High  
Indoor  
temp.  
320  
300  
280  
260  
240  
220  
200  
180  
160  
140  
°F (°C)  
85 (30)  
80 (27)  
75 (24)  
70 (21)  
1
59  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
(15)  
Outdoor ambient temp. °F (°C)  
1459_X_S  
• Low Pressure  
Low pressure characteristics versus outdoor ambient temperature and indoor temperature.  
(Indoor relative humidity: 50%, Indoor fan speed: High)  
230V / 208V  
Outdoor fan speed  
Low  
High  
Indoor  
temp.  
°F (°C)  
100  
90  
80  
70  
60  
50  
40  
85 (30)  
80 (27)  
75 (24)  
70 (21)  
59  
(15)  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
Outdoor ambient temp. °F (°C)  
1460_X_S  
SM830082  
I - 85  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-9 Performance Charts  
Cooling Characteristics  
(2) Operating Pressure  
1 Indoor Unit: 42 Type  
• High Pressure  
Outdoor Unit: CH4242  
High pressure characteristics versus outdoor ambient temperature and indoor temperature.  
(Indoor relative humidity: 50%, Indoor fan speed: High)  
230V / 208V  
Outdoor fan speed  
Low  
High  
340  
320  
300  
280  
260  
240  
220  
200  
180  
160  
Indoor  
temp.  
°F (°C)  
85 (30)  
80 (27)  
75 (24)  
70 (21)  
1
59  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
(15)  
Outdoor ambient temp. °F (°C)  
2228_X_S  
• Low Pressure  
Low pressure characteristics versus outdoor ambient temperature and indoor temperature.  
(Indoor relative humidity: 50%, Indoor fan speed: High)  
230V / 208V  
Outdoor fan speed  
Low  
High  
100  
90  
80  
70  
60  
50  
40  
Indoor  
temp.  
°F (°C)  
85 (30)  
80 (27)  
75 (24)  
70 (21)  
59  
(15)  
68  
(20)  
77  
(25)  
86  
(30)  
95  
(35)  
104  
(40)  
Outdoor ambient temp. °F (°C)  
1162_X_S  
SM830082  
I - 86  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-9 Performance Charts  
Heating Characteristics  
(2) Operating Pressure  
1 Indoor Unit: 24 Type  
• High Pressure  
Outdoor Unit: CH2442  
High pressure characteristics versus outdoor ambient temperature and indoor temperature.  
(Indoor relative humidity: 50%, Indoor fan speed: High)  
230V / 208V  
Indoor  
temp.  
°F (°C)  
75 (24)  
70 (21)  
65 (18)  
340  
320  
300  
280  
260  
240  
220  
200  
180  
1
14  
(–10)  
23  
(–5)  
32  
( 0 )  
41  
( 5 )  
50  
(10)  
59  
(15)  
68  
(20)  
Outdoor ambient temp. °F (°C)  
1165_X_S  
• Low Pressure  
Low pressure characteristics versus outdoor ambient temperature and indoor temperature.  
(Indoor relative humidity: 50%, Indoor fan speed: High)  
230V / 208V  
Indoor  
temp.  
°F (°C)  
90  
80  
70  
60  
50  
40  
30  
75 (24)  
70 (21)  
65 (18)  
14  
(–10)  
23  
(–5)  
32  
( 0 )  
41  
( 5 )  
50  
(10)  
59  
(15)  
68  
(20)  
Outdoor ambient temp. °F (°C)  
1166_X_S  
SM830082  
I - 87  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-9 Performance Charts  
Heating Characteristics  
(2) Operating Pressure  
1 Indoor Unit: 36 Type  
• High Pressure  
Outdoor Unit: CH3642  
High pressure characteristics versus outdoor ambient temperature and indoor temperature.  
(Indoor relative humidity: 50%, Indoor fan speed: High)  
230V / 208V  
Indoor  
temp.  
°F (°C)  
75 (24)  
70 (21)  
65 (18)  
340  
320  
300  
280  
260  
240  
220  
200  
180  
1
14  
(–10)  
23  
(–5)  
32  
( 0 )  
41  
( 5 )  
50  
(10)  
59  
(15)  
68  
(20)  
Outdoor ambient temp. °F (°C)  
1165_X_S  
SM830082  
I - 88  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-9 Performance Charts  
Heating Characteristics  
(2) Operating Pressure  
1 Indoor Unit: 42 Type  
• High Pressure  
Outdoor Unit: CH4242  
High pressure characteristics versus outdoor ambient temperature and indoor temperature.  
(Indoor relative humidity: 50%, Indoor fan speed: High)  
230V / 208V  
Indoor  
temp.  
°F (°C)  
340  
320  
300  
280  
260  
240  
220  
200  
180  
75 (24)  
70 (21)  
65 (18)  
1
14  
(–10)  
23  
(–5)  
32  
( 0 )  
41  
( 5 )  
50  
(10)  
59  
(15)  
68  
(20)  
Outdoor ambient temp. °F (°C)  
2229_X_S  
• Low Pressure  
Low pressure characteristics versus outdoor ambient temperature and indoor temperature.  
(Indoor relative humidity: 50%, Indoor fan speed: High)  
230V / 208V  
Indoor  
temp.  
°F (°C)  
90  
80  
70  
60  
50  
40  
30  
75 (24)  
70 (21)  
65 (18)  
14  
(–10)  
23  
(–5)  
32  
( 0 )  
41  
( 5 )  
50  
(10)  
59  
(15)  
68  
(20)  
Outdoor ambient temp. °F (°C)  
2230_X_S  
SM830082  
I - 89  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-10 Noise Criterion Curves  
4-Way Air Discharge Semi-concealed Type  
MODEL  
: XH2442  
SOUND LEVEL : HIGH 38 dB(A), NC 31  
LOW 31 dB(A), NC 23  
CONDITION  
: Center, Under the unit 4.9 ft.  
208 - 230 V, 1 Phase, 60 Hz  
SOURCE  
:
60  
50  
40  
30  
NC-50  
NC-40  
NC-30  
NC-20  
1
APPROXIMATE  
THRESHOLD OF  
HEARING FOR  
CONTINUOUS  
NOISE  
20  
10  
63  
125 250 500 1000 2000 4000 8000  
BAND CENTER FREQUENCIES, Hz  
2108_X_I  
MODEL  
: XH3642  
MODEL  
: XH4242  
SOUND LEVEL : HIGH 44 dB(A), NC 37  
LOW 33 dB(A), NC 25  
SOUND LEVEL : HIGH 45 dB(A), NC 38  
LOW 34 dB(A), NC 27  
CONDITION  
SOURCE  
60  
: Center, Under the unit 4.9 ft.  
208 - 230 V, 1 Phase, 60 Hz  
CONDITION  
SOURCE  
60  
: Center, Under the unit 4.9 ft.  
208 - 230 V, 1 Phase, 60 Hz  
:
:
50  
40  
30  
50  
40  
30  
NC-50  
NC-50  
NC-40  
NC-30  
NC-20  
NC-40  
NC-30  
NC-20  
APPROXIMATE  
THRESHOLD OF  
HEARING FOR  
CONTINUOUS  
NOISE  
APPROXIMATE  
THRESHOLD OF  
HEARING FOR  
CONTINUOUS  
NOISE  
20  
10  
20  
10  
63  
125 250 500 1000 2000 4000 8000  
BAND CENTER FREQUENCIES, Hz  
63  
125 250 500 1000 2000 4000 8000  
BAND CENTER FREQUENCIES, Hz  
211S0_XM_I830082  
2109_X_I  
I - 90  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-10 Noise Criterion Curves  
Ceiling Mounted Type  
MODEL  
: TH2442  
MODEL  
: TH3642  
SOUND LEVEL : HIGH 40 dB(A), NC 34  
LOW 36 dB(A), NC 26  
SOUND LEVEL : HIGH 46 dB(A), NC 39  
LOW 37 dB(A), NC 31  
CONDITION  
:
Distance 3.3 ft., Under the unit 3.3 ft.  
CONDITION  
:
Distance 3.3 ft., Under the unit 3.3 ft.  
SOURCE  
: 208 - 230 V, 1 Phase, 60 Hz  
SOURCE  
: 208 - 230 V, 1 Phase, 60 Hz  
60  
60  
50  
40  
30  
50  
40  
30  
NC-50  
NC-50  
NC-40  
NC-30  
NC-20  
NC-40  
NC-30  
NC-20  
1
APPROXIMATE  
APPROXIMATE  
THRESHOLD OF  
HEARING FOR  
CONTINUOUS  
NOISE  
THRESHOLD OF  
HEARING FOR  
CONTINUOUS  
NOISE  
20  
10  
20  
10  
63  
125 250 500 1000 2000 4000 8000  
63  
125 250 500 1000 2000 4000 8000  
BAND CENTER FREQUENCIES, Hz  
BAND CENTER FREQUENCIES, Hz  
1221_X_I  
2113_X_I  
MODEL  
: TH4242  
SOUND LEVEL : HIGH 47 dB(A), NC 40  
LOW 38 dB(A), NC 32  
CONDITION  
:
Distance 3.3 ft., Under the unit 3.3 ft.  
SOURCE  
: 208 - 230 V, 1 Phase, 60 Hz  
60  
50  
40  
30  
NC-50  
NC-40  
NC-30  
NC-20  
APPROXIMATE  
THRESHOLD OF  
HEARING FOR  
CONTINUOUS  
NOISE  
20  
10  
63  
125 250 500 1000 2000 4000 8000  
BAND CENTER FREQUENCIES, Hz  
SM830082  
2114_X_I  
I - 91  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-10 Noise Criterion Curves  
Concealed Duct Type  
MODEL  
: UH2442  
MODEL  
: UH3642  
SOUND LEVEL : HIGH 34 dB(A), NC 22 / LOW 27 dB(A), NC 18  
CONDITION : Under the unit 4.9 ft.  
SOUND LEVEL : HIGH 38 dB(A), NC 30 / LOW 31 dB(A), NC 21  
CONDITION : Under the unit 4.9 ft.  
SOURCE  
: 208 - 230 V, 1 Phase, 60 Hz  
SOURCE  
: 208 - 230 V, 1 Phase, 60 Hz  
60  
50  
40  
60  
50  
40  
NC-50  
NC-50  
NC-40  
NC-30  
NC-40  
NC-30  
30  
30  
20  
20 APPROXIMATE  
APPROXIMATE  
NC-20  
NC-20  
THRESHOLD OF  
HEARING FOR  
CONTINUOUS  
NOISE  
THRESHOLD OF  
HEARING FOR  
CONTINUOUS  
NOISE  
1
10  
10  
63 125 250 500 1000 2000 4000 8000  
BAND CENTER FREQUENCIES, Hz  
63 125 250 500 1000 2000 4000 8000  
BAND CENTER FREQUENCIES, Hz  
1761_U_I  
1762_U_I  
SM830082  
I - 92  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-10 Noise Criterion Curves  
Wall Mounted Type  
MODEL  
: KH2442  
MODEL  
: KH3642  
SOUND LEVEL : HIGH 45 dB(A), NC 38  
LOW 40 dB(A), NC 33  
SOUND LEVEL : HIGH 48 dB(A), NC 41  
LOW 40 dB(A), NC 33  
CONDITION  
: Distance 3.3 ft., Under the unit 3.3 ft.  
208 - 230 V, 1 Phase, 60 Hz  
CONDITION  
: Distance 3.3 ft., Under the unit 3.3 ft.  
208 - 230 V, 1 Phase, 60 Hz  
SOURCE  
:
SOURCE  
:
60  
60  
50  
40  
30  
50  
40  
30  
NC-50  
NC-50  
NC-40  
NC-30  
NC-20  
NC-40  
NC-30  
NC-20  
1
APPROXIMATE  
THRESHOLD OF  
HEARING FOR  
CONTINUOUS  
NOISE  
APPROXIMATE  
THRESHOLD OF  
HEARING FOR  
CONTINUOUS  
NOISE  
20  
10  
20  
10  
63  
125 250 500 1000 2000 4000 8000  
BAND CENTER FREQUENCIES, Hz  
63  
125 250 500 1000 2000 4000 8000  
BAND CENTER FREQUENCIES, Hz  
2120_K_I  
2119_K_I  
SM830082  
I - 93  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-10 Noise Criterion Curves  
Outdoor Units  
MODEL  
: CH2442  
MODEL  
: CH3642  
SOUND LEVEL : 53 dB(A), NC 44  
SOUND LEVEL : 56 dB(A), NC 45  
CONDITION : Distance 1m, Height 1m  
CONDITION : Distance 1m, Height 1m  
SOURCE  
: 230 - 208 V, 1 Phase, 60 Hz  
SOURCE  
: 230 - 208 V, 1 Phase, 60 Hz  
90  
90  
80  
70  
80  
70  
60  
50  
40  
30  
20  
60  
50  
40  
30  
20  
APPROXIMATE  
APPROXIMATE  
THRESHOLD OF  
CONTINUOUS  
NOISE  
THRESHOLD OF  
HEARING FOR  
CONTINUOUS  
NOISE  
1
10  
8000  
1000 2000 4000  
250  
60  
125  
500  
10  
63  
125 250 500 1000 2000 4000 8000  
BAND CAENTER FREQUENCIES, Hz  
0598_C_S  
BAND CENTER FREQUENCIES, Hz  
0597_C_S  
MODEL  
: CH4242  
SOUND LEVEL : 56 dB(A), NC 47  
CONDITION : Distance 1m, Height 1m  
SOURCE  
: 230 - 208 V, 1 Phase, 60 Hz  
90  
80  
70  
60  
50  
40  
30  
20  
APPROXIMATE  
THRESHOLD OF  
HEARING FOR  
CONTINUOUS  
NOISE  
10  
63  
125 250 500 1000 2000 4000 8000  
BAND CENTER FREQUENCIES, Hz  
0599_C_S  
REMARKS: 1. Value obtained in the actual place where the unit is installed may be slightly higher than the values  
shown in this graph because of the conditions of operation, the structure of the building, the background  
noise and other factors.  
2. The test results were obtained from an anechoic room.  
NOTE  
To evaluate “Noise level” the maximum number of the measured OCTAVE BAND SOUND PRESSURE LEVEL is used.  
Read the number on each BAND CENTER FREQUENCIES (horizontal axis) ranging from 63 Hz to 8000 Hz and select  
the maximum value (vertical axis) among them.  
SM830082  
I - 94  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-11 Increasing the Fan Speed  
Electrical component box  
If external static pressure is too great (due to long  
extension of ducts, for example), the air flow volume  
may drop too low at each air outlet. This problem may  
be solved by increasing the fan speed using the  
following procedure:  
Jumper cable  
Fan  
motor  
Jumper cable  
Fan motor socket  
(At shipment)  
(Jumper cable installed)  
2159_M_I  
(1) Remove 4 screws on the electrical component  
box and remove the cover plate.  
12 Type  
18 Type  
150  
100  
50  
150  
(2) Disconnect the fan motor sockets in the box.  
0.5  
0.4  
0.5  
0.4  
(3) Take out the jumper cable (sockets at both  
ends) clamped in the box.  
100  
50  
0
0.3  
0.2  
0.1  
0
0.3  
0.2  
(4) Securely connect the jumper cable sockets  
between the disconnected fan motor sockets in  
step 2.  
HT  
HH  
HT  
HH  
0.1  
0
H
L
(5) Place the cable neatly in the box and reinstall  
the cover plate.  
H
L
1
0
200  
300  
400  
500  
200  
300  
400  
Air Flow (CFM)  
Air Flow (CFM)  
1981_U_I  
1980_U_I  
Indoor Fan Performance  
24 Type  
36 Type  
200  
150  
100  
50  
0.8  
0.6  
0.5  
0.4  
0.3  
0.2  
0.1  
150  
100  
50  
0.5  
0.4  
0.3  
0.2  
0.1  
0
HT  
HT  
HH  
HH  
H
H
L
L
0
0
0
300  
500  
700  
900  
500  
1000  
Air Flow (CFM)  
Air Flow (CFM)  
1982_U_I  
1983_U_I  
NOTE  
HT : Using the booster cable  
H : At shipment  
How to read the diagram  
The vertical axis is the external static pressure (Pa) while the horizontal axis represents the AIR FLOW (CFM).  
The characteristic curves for “HT”, “H”, “M” and “L” fan speed control are shown.  
The nameplate values are shown based on the “H” air flow. For the 24 type, the air flow is 636 CFM, while the  
external static pressure is 49 Pa at “H” position. If external static pressure is too great (due to long extension of  
duct, for example), the air flow volume may drop too low at each air outlet.  
This problem may be solved by increasing the fan speed as explained above.  
SM830082  
I - 95  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-12 Air throw distance chart  
4-Way Air Discharge Semi-concealed Type  
Model: 24 Type  
HORIZONTAL DISTANCE (ft.)  
0
3
7
10  
13  
17  
20  
0
3
AXIS AIR VELOCITY  
7
10  
13  
2111_X_I  
1
Model: 36, 42 Type  
HORIZONTAL DISTANCE (ft.)  
0
3
7
10  
13  
17  
20  
0
3
AXIS AIR VELOCITY  
7
10  
13  
2112_X_I  
: LOUVER ANGLE 20˚ in Cooling mode  
: LOUVER ANGLE 60˚ in Heating mode  
Condition Fan Speed : Hi  
Room air temp. : 80 ˚C DB in cooling mode  
68 ˚C DB in heating mode  
SM830082  
I - 96  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-12 Air throw distance chart  
Ceiling Mounted Type  
Model: 24 Type  
HORIZONTAL DISTANCE (ft.)  
0
3
7
10 13 17 20 23 26 29 33  
0
3
AXIS AIR VELOCITY  
7
10  
13  
17  
2115_T_I  
Model: 36 Type  
HORIZONTAL DISTANCE (ft.)  
0
3
7
10 13 17 20 23 26 29 33  
0
3
AXIS AIR VELOCITY  
1
7
10  
13  
17  
2116_T_I  
Model: 42 Type  
HORIZONTAL DISTANCE (ft.)  
0
3
7
10 13 17 20 23 26 29 33  
0
3
AXIS AIR VELOCITY  
7
10  
13  
17  
COOLING  
HIGH  
HEATING  
HIGH  
68˚ F  
FAN SPEED  
ROOM AIR TEMP.  
LOUVER ANGLE  
80˚ F  
– 7˚  
54˚  
: COOLING  
: HEATING  
2117_T_I  
SM830082  
I - 97  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-12 Air throw distance chart  
Wall Mounted Type  
MODEL: KHS2442  
Horizontal distance (ft.)  
25 30  
0
5
10  
15  
20  
45°  
5
10  
15  
0°  
67.5°  
22.5°  
45°  
2121_K_S  
1
COOLING - - - - - HEATING  
FAN SPEED  
ROOM AIR TEMP. 80°F  
FLAP ANGLE 0°, 22.5°, 45°  
HIGH  
HIGH  
70°F  
54°, 67.5°  
MODEL: KHS3642  
Horizontal distance (ft.)  
15 20  
0
5
5
10  
25  
30  
33  
45°  
0°  
67.5°  
45°  
10  
13  
22.5°  
2122_K_S  
COOLING - - - - - HEATING  
FAN SPEED  
ROOM AIR TEMP. 80°F  
FLAP ANGLE 0°, 22.5°, 45°  
HIGH  
HIGH  
70°F  
45°, 67.5°  
SM830082  
I - 98  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
1-13 Installation Instructions  
Tubing Length  
Refrigerant tubing between the indoor and  
outdoor units should be kept as short as  
possible.  
Tubing length (L)  
INDOOR  
UNIT  
Select and decide the installation location so  
that the length of the refrigerant tubing will be  
within the limits given in Table 1-10.  
Elevation difference (H)  
OUTDOOR  
UNIT  
0711_M_I  
Fig. 1-1  
Table 1-10  
Models  
Narrow tube in. (mm)  
CH2442  
CH3642, CH4242  
Tubing Data  
1/4 (6.35)  
3/4 (19.05)  
165  
3/8 (9.52)  
3/4 (19.05)  
165  
Tubing size  
outer dia.  
Wide tube  
in. (mm)  
(ft.)  
1
Limit of tubing length  
Outdoor unit is higher  
Limit of elevation  
difference between  
the 2 units  
165  
165  
100  
than indoor unit  
(ft.)  
Outdoor unit is lower  
than indoor unit  
100  
(ft.)  
Max. allowable tubing length at shipment (ft.)  
Required additional refrigerant (oz./ft.)  
100  
0.48*1  
100  
0.53*2  
No additional charge of compressor oil is necessary.  
1
*
*
If total tubing length becomes 100 to 165 ft., charge additional refrigerant (R22) by 0.48 oz./ft..  
If total tubing length becomes 100 to 165 ft., charge additional refrigerant (R22) by 0.53 oz./ft..  
2
SM830082  
I - 99  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
SELECTING THE INSTALLATION SITE  
Indoor Unit  
Ceiling-Mounted Type  
AVOID:  
Ceiling  
areas where leakage of flammable gas may be  
expected.  
places where large amounts of oil mist exist.  
Wall  
direct sunlight.  
locations near inverter lamps which may affect  
Min.10 inch  
Min.10 inch  
Front view  
performance of the unit.  
NOTE  
locations near heat sources which may affect  
The rear of the indoor unit can be installed flush  
against the wall.  
performance of the unit.  
Ceiling  
Air  
discharge  
locations where external air may enter the room  
directly. This may cause “sweating” on the air  
discharge ports, causing them to spray or drip.  
Air intake  
Min.2 ft.  
locations where the remote control unit will be  
splashed with water or affected by dampness or  
humidity.  
1
Side view  
installing the remote control unit behind curtains or  
1091_T_I  
furniture.  
locations where the receiver in the indoor unit is  
exposed to the inverter lamp light. Faulty operation  
of the unit occurs.  
4-Way Air Discharge Type  
Concealed-Duct Type  
DO:  
select an appropriate position from which every  
corner of the room can be uniformly cooled.  
select a location where the ceiling is strong enough  
to support the weight of the unit.  
select a location where tubing and drain pipe have  
the shortest run to the outdoor unit.  
allow room for operation and maintenance as well  
Wall-Mounted Type  
as unrestricted air flow around the unit.  
install the unit within the maximum elevation  
difference above or below the outdoor unit and  
within a total tubing length from the outdoor unit as  
detailed in Table 1-10.  
Min.  
6 inch  
Min.  
Min.  
allow room for mounting the remote control unit  
about 3 ft. off the floor, in an area that is not in  
direct sunlight nor in the flow of cool air from the  
indoor unit.  
6 inch  
12 inch  
0930_K_I  
NOTE  
Air delivery will be degraded if the distance from the  
floor to the ceiling is greater than 10 ft..  
SM830082  
I - 100  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Exhaust fan  
Outdoor Unit  
AVOID:  
Hot air  
Heat source  
Out-  
door  
unit  
heat sources, exhaust fans, etc. (Fig. 2-1)  
damp, humid or uneven locations.  
0591_C_I  
DO:  
Fig. 2-1  
choose a place as cool as possible.  
choose a place that is well ventilated and outside  
air temperature does not exceed maximum 115°F  
constantly.  
Obstacle above  
Min.  
1 inch  
Min.  
1 inch  
Min.  
7 ft.  
allow enough room around the unit for air intake/  
4 in.  
exhaust and possible maintenance. (Fig. 2-2)  
Air  
provide a solid base; about 6 inch above ground level  
to reduce humidity and possible water damage in  
the unit and decreased service life. (Fig. 2-3)  
use lug bolts or equivalent to bolt down unit,  
reducing vibration and noise.  
dis-  
charge  
1
Min. 2 ft.  
0931_C_I  
Ground  
0932_C_I  
Fig. 2-2  
In case of multiple installations  
Unit spacing if air discharge chamber is not used.  
Unit spacing when air discharge chamber is used.  
Min. 8 inch  
Min. 4 ft.  
Min. 4 ft.  
Min. 5 ft.  
Min. 1 ft.  
Min. 4 ft.  
Min. 4 ft.  
Min. 1 ft. 2 inch  
Min. 1 ft. 2 inch  
Air  
discharge  
chamber  
Min. 12 ft.  
Min. 1 ft.  
Min. 8 inch  
Min. 1 ft.  
If you would like to make the separation smaller on the air  
discharge side, use an air discharge chamber.  
You can install any number of units side-by -side.  
Only up to 3 units can be installed side-by-side under the above  
conditions. The next group must be spaced at least 1 ft. away  
from the first group.  
0933_C_S  
Air in  
Air in  
Air  
discharge  
Concrete block  
4 inch × 1 ft. 4 inch  
beams or equal  
Min. 6 inch  
Anchor bolts  
(4 pieces)  
0934_C_I  
Fig. 2-3  
SM830082  
I - 101  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Air Discharge Chamber for Top Discharge  
Air discharge  
Install the air-discharge chamber in the field when:  
it is difficult to keep a space of minimum 2 ft.  
between the air-discharge outlet and the obstacle.  
the air-discharge outlet is facing the sidewalk and  
discharge hot air can annoy the passers-by.  
Refer to Fig. 2-4.  
0426_C_I  
22-5/16"  
Recommended outer dimensions of wind shield  
(field supply)  
3-ø2-3/8" hole  
11-13/16"  
3 - ø1-9/16" hole  
1
21-13/16"  
6 - ø15/64" hole  
1-7/32"  
9-27/32"  
9-27/32"  
5-5/32"  
5-5/32"  
23-5/16"  
21-13/16"  
0936_C_I  
1352_C_I  
CH3642  
CH2442  
Fig. 2-4  
Installing the Outdoor Unit in Heavy  
Snow Areas  
In locations subject to strong winds, snow-proof  
ducting should be fitted and direct exposure to the  
wind should be avoided as much as possible.  
The following problems may occur when the outdoor  
unit is not provided with a platform and snow-proof  
ducting.  
a) The outdoor fan may not run and there may be  
damage to the unit  
b) There may be no air flow.  
c) The tubing may freeze and burst.  
d) The condenser pressure may drop because of  
strong wind, and the indoor unit may freeze.  
SM830082  
I - 102  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Precautions When Installing in Heavy  
Snow Areas  
(1) The platform should be higher than the maximum.  
snow depth. (Fig. 2-5)  
In regions with snow fall, the outdoor unit should be  
provided with a platform and snow-proof duct.  
(2) The two anchoring feet of the outdoor unit should  
be attached to the platform, and the platform  
should be installed beneath the air-intake side of  
the outdoor unit.  
(3) The platform foundation must be solid and the  
unit must be secured with anchor bolts.  
(4) When installing on a roof subject to strong wind,  
countermeasures must be taken to prevent the  
unit from being overturned.  
Without snow-  
proof ducting  
(Low platform)  
Snow-proof  
ducting  
(High platform)  
Dimensions of Snow / Wind-proof Ducting  
and Refrigerant Tubing Space for Installation  
0937_C_I  
Fig. 2-5  
Fig. 2-6  
1
Min. 4"  
Outdoor  
Unit  
12"  
Duct  
Duct  
12"  
Outdoor Unit  
Duct  
Duct  
Min. 4"  
Unit: inch  
1117_C_I  
Higher than the  
maximum  
snow depth  
Air  
Intake  
Air  
Intake  
Platform (foundation)  
About 1/2 of the  
unit height  
0488_C_I  
Fig. 2-7  
Example of Installation  
0490_C_I  
Fig. 2-8  
SM830082  
I - 103  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
ELECTRICAL WIRING  
General Precautions on Wiring  
(7) Regulations on wire diameters differ from locality  
to locality. For field wiring rules, must follow your  
LOCAL ELECTRICAL CODES before beginning.  
(1) Before wiring, confirm the rated voltage of the  
unit as shown on its nameplate, then carry out  
the wiring closely following the wiring diagram.  
(2) Provide a power outlet to be used exclusively for  
each unit, and a power supply disconnect and  
circuit breaker for overcurrent protection should  
be provided in the exclusive line.  
You must ensure that installation complies with all  
relevant rules and regulations.  
(8) To prevent malfunction of the air conditioner  
caused by electrical noise, care must be taken  
when wiring as follows:  
(3) To prevent possible hazards from insulation  
failure, the unit must be grounded.  
The remote control wiring and the inter-unit  
control wiring should be wired apart from the  
inter-unit power wiring.  
(4) Each wiring connection must be done in accor-  
dance with the wiring system diagram. Wrong  
wiring may cause the unit to misoperate or  
become damaged.  
Use shielded wires for inter-unit control wiring  
between units and ground the shield on both  
sides.  
(5) Do not allow wiring to touch the refrigerant tubing,  
compressor, or any moving parts of the fan.  
(6) Unauthorized changes in the internal wiring can  
be very dangerous. The manufacturer will  
accept no responsibility for any damage or  
misoperation that occurs as a result of such  
unauthorized changes.  
1
(9) If the power supply cord of this appliance is  
damaged, it must be replaced by a repair shop  
appointed by the manufacture, because special  
purpose tools are required.  
(10) All wiring must be used class 1.  
Recommended Wire Length and Wire Diameter for Power Supply System  
Must follow LOCAL ELECTRICAL CODES for wiring.  
Outdoor Unit  
* AWG = American Wire Gauge  
MOP  
Trade size  
of Conduit  
Trade size  
of Conduit  
(A) Power Supply  
Power Supply Terminal Base  
Capacity Max. Wire Diameter  
Model Name  
(Fuse or HACR  
type circuit braker)  
AWG #12  
CH2442  
CH3642  
3/4 in.  
3/4 in.  
3/4 in.  
25 A  
50 A  
AWG #6  
AWG #6  
AWG #6  
1-1/4 in.  
1-1/4 in.  
1-1/4 in.  
Max. length 69 ft.  
AWG #12  
Max. length 69 ft.  
AWG #10  
Max. length 67 ft.  
35 A/40 A (230/208 V) 50 A  
CH4242  
45 A  
50 A  
Indoor Unit  
MOP  
Trade size  
of Conduit  
Trade size  
of Conduit  
(B) Power Supply  
Max. length 330 ft.  
Power Supply Terminal Base  
Capacity Max. Wire Diameter  
Type  
(Fuse or HACR  
type circuit braker)  
X, K, T, U  
3/4 in.  
15 A  
25 A  
AWG #10  
3/4 in.  
Control Wiring  
(C) Inter-Unit Control Wiring  
AWG #18 (0.75 mm2)  
Use high voltage wire (300 V)*1  
Max. 3,300 ft.  
(D) Remote Control Wiring  
(E) Control Wiring For Group Control  
AWG #18* (0.75 mm2)  
AWG #18*2 (0.75 mm2)  
Max. 1,650 ft.  
Max. 1,650 ft. (Total)  
1
NOTE  
*
*
With ring type wire terminal.  
2
Wire joint connection.  
SM830082  
I - 104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Wiring System Diagrams  
(1) Basic wiring diagram for standard control  
Indoor Unit  
Outdoor Unit  
B
R.C. Address on the PCB: 0 (S2, BLK)  
(0: Factory shipped state)  
1
2
1
2
Inter-unit  
0
power wiring  
Single phase  
230/208V  
G
G
Ground  
Inter-unit  
control wiring  
(Low voltage)  
U1  
U2  
U1  
L1  
U2  
L1  
Power supply  
Single phase  
230/208V  
C
L2  
L2  
G
1
2
1
2
1
2
Ground  
D
A
Remote controller  
(Option)  
*Remote controller wirings are wire joint connection.  
2085_M_I  
NOTE  
CH Type  
(1) Refer to “Recommended Wire Length and Wide  
Diameter for Power Supply System” for the  
explanation of “A”, “B”, “C”, “D”, and “E”, in the  
above diagrams.  
5P terminal board + 2P terminal board  
1
1
2 G L1 L2  
U1 U2  
Inter-unit  
control wiring  
(2) Inter-Unit Control Wiring (C) and remote control-  
ler wiring (D), (E) has no polarity.  
Power  
supply  
Inter-unit  
power wiring  
2086_M_I  
But for other wiring, respect polarity.  
Be sure to connect as shown in the Wiring  
System Diagram.  
KH Type  
XH, TH, UH Type  
4P terminal board  
5P terminal board  
(3) R.C. Address should be set before turning the  
power on.  
(4) Regarding the R.C. Address setting, refer to  
Auto. address setting can be executed by a  
remote controller automatically.  
U1 U2  
Inter-unit  
1
2
1
2
U1 U2  
Remote  
controller wiring  
Remote  
Inter-unit  
Inter-unit  
Inter-unit  
controller wiring  
control wiring power wiring  
power wiring  
control wiring  
2103_M_I  
2103_M_I  
2088_M_I  
2087_M_I  
SM830082  
I - 105  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
(2) Basic wiring diagram for group control  
This diagram shows when several units (max. 8) are  
controlled by a remote controller. In this case, a  
remote controller can be connected at any indoor unit.  
Indoor Unit  
Outdoor Unit  
B
*1  
R.C. Address on the PCB: 1 (S2, BLK)  
1
2
1
2
Inter-unit  
power wiring  
single phase  
230/208V  
G
G
Ground  
Ground  
Ground  
Inter-unit  
control wiring  
(Low voltage)  
U1  
U2  
U1  
U2  
4
L1  
L1  
Power supply  
single phase  
230/208V  
C
L2  
1
2
1
2
1
2
L2  
G
RED  
BLK  
Ground  
A
A
A
Remote controller  
(Option)  
D
E
Indoor Unit  
Outdoor Unit  
1
B
R.C. Address on the PCB: 2 (S2, BLK)  
1
2
1
2
Inter-unit  
power wiring  
single phase  
230/208V  
Inter-unit  
control wiring  
(Low voltage)  
U1  
U2  
U1  
U2  
4
L1  
L1  
Power supply  
single phase  
230/208V  
C
L2  
1
2
L2  
G
Ground  
E
Indoor Unit  
Outdoor Unit  
B
R.C. Address on the PCB: 8 (S2, BLK)  
1
2
1
2
Inter-unit  
power wiring  
single phase  
230/208V  
Inter-unit  
control wiring  
(Low voltage)  
U1  
U2  
U1  
U2  
4
L1  
L1  
Power supply  
single phase  
230/208V  
C
L2  
1
2
L2  
G
Ground  
*Remote controller wirings are wire joint connection.  
2089_M_I  
NOTE  
R.C. Address should be set before turning the power on.  
Auto. address setting can be executed by a remote controller automatically.  
Please refer to “Automatic Address Setting Method”.  
Each successive unit will respond at one-second intervals following the order of the R.C. address when the  
remote controller is operated.  
SM830082  
I - 106  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Electrical characteristics  
Electrical Data  
Indoor model: XH2442 / Outdoor model: CH2442  
Cooling  
Indoor Unit  
Outdoor Unit  
Fan Motor Compressor  
230 - 208 V / 1 phase / 60 Hz 230 - 208 V / 1 phase / 60 Hz  
Complete Unit  
Fan Motor  
Performance at  
A
kW  
A
0.6 - 0.6  
0.12 - 0.11  
0.6 - 0.6  
0.12 - 0.11  
1 - 1  
0.9 - 0.9  
0.18 - 0.17  
0.9 - 0.9  
0.18 - 0.17  
1 - 1  
9.7 - 10.1  
2.15 - 2.07  
11.1 - 12.0  
2.50 - 2.47  
66 - 60  
11.2 - 11.6  
Rating conditions  
2.45 - 2.35  
12.6 - 13.5  
2.80 - 2.75  
68 - 62  
Full load conditions  
Starting amperes  
Heating  
kW  
A
1
Indoor Unit  
Outdoor Unit  
Compressor  
230 - 208 V / 1 phase / 60 Hz 230 - 208 V / 1 phase / 60 Hz  
Complete Unit  
Fan Motor  
Fan Motor  
Performance at  
A
kW  
A
0.4 - 0.4  
0.09 - 0.08  
0.4 - 0.4  
0.09 - 0.08  
1 - 1  
0.9 - 0.9  
0.18 - 0.17  
0.9 - 0.9  
0.18 - 0.17  
1 - 1  
10.4 - 11.0  
2.23 - 2.20  
10.8 - 11.7  
2.43 - 2.40  
66 - 60  
11.7 - 12.3  
Rating conditions  
2.50 - 2.45  
12.1 - 13.0  
2.70 - 2.65  
68 - 62  
Full load conditions  
Starting amperes  
kW  
A
Cooling:  
Rating Conditions  
: Indoor Air Temperature  
80 °F DB / 67 °F WB  
Outdoor Air Temperature 95 °F DB  
Full Load Conditions : Indoor Air Temperature  
Outdoor Air Temperature 115 °F DB  
80 °F DB / 67 °F WB  
Heating:  
Rating Conditions  
: Indoor Air Temperature  
Outdoor Air Temperature 47 °F DB / 43 °F WB  
Full Load Conditions : Indoor Air Temperature  
70 °F DB / 60 °F WB  
80 °F DB / — °F WB  
Outdoor Air Temperature 45 °F DB / 35 °F WB  
SM830082  
I - 107  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor model: XH3642 / Outdoor model: CH3642  
Cooling  
Indoor Unit  
Outdoor Unit  
Fan Motor Compressor  
230 - 208 V / 1 phase / 60 Hz 230 - 208 V / 1 phase / 60 Hz  
Complete Unit  
Fan Motor  
Performance at  
A
kW  
A
0.9 - 0.8  
0.20 - 0.16  
0.9 - 0.8  
0.20 - 0.16  
1 - 1  
1.8 - 1.8  
0.36 - 0.34  
1.8 - 1.8  
0.36 - 0.34  
2 - 2  
12.7 - 13.2  
2.79 - 2.70  
15.4 - 16.7  
3.43 - 3.41  
95 - 86  
15.4 - 15.8  
Rating conditions  
3.35 - 3.20  
18.1 - 19.3  
3.99 - 3.91  
98 - 89  
Full load conditions  
Starting amperes  
Heating  
kW  
A
1
Indoor Unit  
Outdoor Unit  
Compressor  
230 - 208 V / 1 phase / 60 Hz 230 - 208 V / 1 phase / 60 Hz  
Complete Unit  
Fan Motor  
Fan Motor  
Performance at  
A
kW  
A
0.7 - 0.6  
0.16 - 0.12  
0.7 - 0.6  
0.16 - 0.12  
1 - 1  
1.8 - 1.8  
0.36 - 0.34  
1.8 - 1.8  
0.36 - 0.34  
2 - 2  
15.7 - 16.9  
3.33 - 3.29  
14.2 - 15.6  
3.16 - 3.21  
95 - 86  
18.2 - 19.3  
Rating conditions  
3.85 - 3.75  
16.7 - 18.0  
3.68 - 3.67  
98 - 89  
Full load conditions  
Starting amperes  
kW  
A
Cooling:  
Rating Conditions  
: Indoor Air Temperature  
80 °F DB / 67 °F WB  
Outdoor Air Temperature 95 °F DB  
Full Load Conditions : Indoor Air Temperature  
Outdoor Air Temperature 115 °F DB  
80 °F DB / 67 °F WB  
Heating:  
Rating Conditions  
: Indoor Air Temperature  
Outdoor Air Temperature 47 °F DB / 43 °F WB  
Full Load Conditions : Indoor Air Temperature  
70 °F DB / 60 °F WB  
80 °F DB / — °F WB  
Outdoor Air Temperature 45 °F DB / 35 °F WB  
SM830082  
I - 108  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Electrical characteristics  
Electrical Data  
Indoor model: XH4242 / Outdoor model: CH4242  
Cooling  
Indoor Unit  
Outdoor Unit  
Fan Motor Compressor  
230 V  
Complete Unit  
Fan Motor  
Performance at  
230 V  
208 V  
0.9  
230 V  
1.8  
208 V  
208 V  
18.3  
3.58  
21.9  
4.33  
131  
230 V  
20.6  
4.2  
208 V  
21.0  
A
kW  
A
1.0  
0.2  
1.0  
0.2  
2
1.8  
0.34  
1.8  
0.34  
2
17.8  
3.64  
21.0  
4.41  
131  
Rating conditions  
0.17  
0.9  
0.36  
1.8  
4.09  
23.8  
4.97  
134  
24.6  
Full load conditions  
Starting amperes  
Heating  
kW  
A
0.17  
2
0.36  
2
4.84  
133.9  
1
Indoor Unit  
Fan Motor  
Outdoor Unit  
Fan Motor Compressor  
230 V 208 V  
Complete Unit  
Performance at  
230 V  
208 V  
0.8  
230 V  
1.8  
208 V  
1.8  
230 V  
21.6  
208 V  
A
kW  
A
0.9  
0.19  
0.9  
0.19  
2
18.9  
3.9  
19.6  
3.85  
22.8  
4.52  
131  
22.2  
4.35  
25.4  
5.02  
133.8  
Rating conditions  
0.16  
0.8  
0.36  
1.8  
0.34  
1.8  
4.45  
21.2  
4.48  
131  
23.9  
Full load conditions  
Starting amperes  
kW  
A
0.16  
2
0.36  
2
0.34  
2
5.03  
133.9  
Cooling:  
Rating Conditions  
: Indoor Air Temperature  
Outdoor Air Temperature 95 °F DB  
Full Load Conditions : Indoor Air Temperature 80 °F DB / 67 °F WB  
Outdoor Air Temperature 115 °F DB  
80 °F DB / 67 °F WB  
Heating:  
Rating Conditions  
: Indoor Air Temperature  
Outdoor Air Temperature 47 °F DB / 43 °F WB  
Full Load Conditions : Indoor Air Temperature  
70 °F DB / 60 °F WB  
80 °F DB / — °F WB  
Outdoor Air Temperature 45 °F DB / 35 °F WB  
SM830082  
I - 109  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor model: TH2442 / Outdoor model: CH2442  
Cooling  
Indoor Unit  
Outdoor Unit  
Fan Motor Compressor  
230 - 208 V / 1 phase / 60 Hz 230 - 208 V / 1 phase / 60 Hz  
Complete Unit  
Fan Motor  
Performance at  
A
kW  
A
0.4 - 0.4  
0.08 - 0.07  
0.4 - 0.4  
0.08 - 0.07  
1 - 1  
0.9 - 0.9  
0.18 - 0.17  
0.9 - 0.9  
0.18 - 0.17  
1 - 1  
9.4 - 10.0  
2.09 - 2.04  
11.0 - 11.7  
2.45 - 2.42  
66 - 60  
10.7 - 11.3  
Rating conditions  
2.35 - 2.28  
12.3 - 13.0  
2.71 - 2.66  
68 - 62  
Full load conditions  
Starting amperes  
Heating  
kW  
A
1
Indoor Unit  
Fan Motor  
Outdoor Unit  
Complete Unit  
Fan Motor  
Compressor  
Performance at  
230 - 208 V / 1 phase / 60 Hz  
230 - 208 V / 1 phase / 60 Hz  
A
kW  
A
0.4 - 0.4  
0.08 - 0.07  
0.4 - 0.4  
0.08 - 0.07  
1 - 1  
0.9 - 0.9  
0.18 - 0.17  
0.9 - 0.9  
0.18 - 0.17  
1 - 1  
10.4 - 11.6  
2.29 - 2.26  
11.4 - 11.8  
2.55 - 2.44  
66 - 60  
11.7 - 12.9  
Rating conditions  
2.55 - 2.50  
12.7 - 13.1  
2.81 - 2.68  
68 - 62  
Full load conditions  
Starting amperes  
kW  
A
Cooling:  
Rating Conditions  
: Indoor Air Temperature  
80 °F DB / 67 °F WB  
Outdoor Air Temperature 95 °F DB  
Full Load Conditions : Indoor Air Temperature  
Outdoor Air Temperature 115 °F DB  
80 °F DB / 67 °F WB  
Heating:  
Rating Conditions  
: Indoor Air Temperature  
Outdoor Air Temperature 47 °F DB / 43 °F WB  
Full Load Conditions : Indoor Air Temperature  
70 °F DB / 60 °F WB  
80 °F DB / — °F WB  
Outdoor Air Temperature 45 °F DB / 35 °F WB  
SM830082  
I - 110  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor model: TH3642 / Outdoor model: CH3642  
Cooling  
Indoor Unit  
Outdoor Unit  
Fan Motor Compressor  
230 - 208 V / 1 phase / 60 Hz 230 - 208 V / 1 phase / 60 Hz  
Complete Unit  
Fan Motor  
Performance at  
A
kW  
A
0.7 - 0.7  
0.16 - 0.14  
0.7 - 0.7  
0.16 - 0.14  
1 - 1  
1.8 - 1.8  
0.36 - 0.34  
1.8 - 1.8  
0.36 - 0.34  
2 - 2  
12.6 - 13.2  
2.83 - 2.69  
15.4 - 16.8  
3.45 - 3.38  
95 - 86  
15.1 - 15.7  
Rating conditions  
3.35 - 3.17  
17.9 - 19.3  
3.97 - 3.86  
97.7 - 88.7  
Full load conditions  
Starting amperes  
Heating  
kW  
A
1
Indoor Unit  
Outdoor Unit  
Compressor  
230 - 208 V / 1 phase / 60 Hz 230 - 208 V / 1 phase / 60 Hz  
Complete Unit  
Fan Motor  
Fan Motor  
Performance at  
A
kW  
A
0.7 - 0.7  
0.16 - 0.14  
0.7 - 0.7  
0.16 - 0.14  
1 - 1  
1.8 - 1.8  
0.36 - 0.34  
1.8 - 1.8  
0.36 - 0.34  
2 - 2  
15.7 - 17.1  
3.43 - 3.41  
13.6 - 14.6  
3.02 - 2.98  
95 - 86  
18.2 - 19.6  
Rating conditions  
3.95 - 3.89  
16.1 - 17.1  
3.54 - 3.46  
97.7 - 88.7  
Full load conditions  
Starting amperes  
kW  
A
Cooling:  
Rating Conditions  
: Indoor Air Temperature  
80 °F DB / 67 °F WB  
Outdoor Air Temperature 95 °F DB  
Full Load Conditions : Indoor Air Temperature  
Outdoor Air Temperature 115 °F DB  
80 °F DB / 67 °F WB  
Heating:  
Rating Conditions  
: Indoor Air Temperature  
Outdoor Air Temperature 47 °F DB / 43 °F WB  
Full Load Conditions : Indoor Air Temperature  
70 °F DB / 60 °F WB  
80 °F DB / — °F WB  
Outdoor Air Temperature 45 °F DB / 35 °F WB  
SM830082  
I - 111  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor model: TH4242 / Outdoor model: CH4242  
Cooling  
Indoor Unit  
Outdoor Unit  
Fan Motor Compressor  
230 V  
Complete Unit  
Fan Motor  
Performance at  
230 V  
208 V  
0.7  
230 V  
1.8  
208 V  
208 V  
18.8  
3.71  
22.6  
4.49  
131  
230 V  
20.6  
4.3  
208 V  
21.3  
4.2  
A
kW  
A
0.8  
0.18  
0.8  
0.18  
1
1.8  
0.34  
1.8  
0.34  
2
18.0  
3.76  
21.0  
4.49  
131  
Rating conditions  
0.15  
0.7  
0.36  
1.8  
23.6  
5.03  
133.8  
25.1  
4.98  
133.7  
Full load conditions  
Starting amperes  
Heating  
kW  
A
0.15  
1
0.36  
2
1
Indoor Unit  
Fan Motor  
Outdoor Unit  
Fan Motor Compressor  
230 V 208 V  
Complete Unit  
Performance at  
230 V  
208 V  
0.7  
230 V  
1.8  
208 V  
1.8  
230 V  
21.7  
208 V  
A
kW  
A
0.8  
0.18  
0.8  
0.18  
1
19.1  
3.91  
21.2  
4.52  
131  
20.0  
3.86  
23.6  
4.67  
131  
22.5  
4.35  
26.1  
5.16  
133.7  
Rating conditions  
0.15  
0.7  
0.36  
1.8  
0.34  
1.8  
4.45  
23.8  
Full load conditions  
Starting amperes  
kW  
A
0.15  
1
0.36  
2
0.34  
2
5.06  
133.8  
Cooling:  
Rating Conditions  
: Indoor Air Temperature  
Outdoor Air Temperature 95 °F DB  
Full Load Conditions : Indoor Air Temperature 80 °F DB / 67 °F WB  
Outdoor Air Temperature 115 °F DB  
80 °F DB / 67 °F WB  
Heating:  
Rating Conditions  
: Indoor Air Temperature  
Outdoor Air Temperature 47 °F DB / 43 °F WB  
Full Load Conditions : Indoor Air Temperature  
70 °F DB / 60 °F WB  
80 °F DB / — °F WB  
Outdoor Air Temperature 45 °F DB / 35 °F WB  
SM830082  
I - 112  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor model: UH2442 / Outdoor model: CH2442  
Cooling  
Indoor Unit  
Outdoor Unit  
Fan Motor Compressor  
230 - 208 V / 1 phase / 60 Hz 230 - 208 V / 1 phase / 60 Hz  
Complete Unit  
Fan Motor  
Performance at  
A
kW  
A
0.9 - 0.8  
0.18 - 0.16  
0.9 - 0.8  
0.18 - 0.16  
2 - 2  
0.9 - 0.9  
0.18 - 0.17  
0.9 - 0.9  
0.18 - 0.17  
1 - 1  
9.7 - 10.4  
2.19 - 2.15  
11.1 - 12  
2.53 - 2.48  
66 - 60  
11.5 - 12.1  
Rating conditions  
2.55 - 2.48  
12.9 - 13.7  
2.89 - 2.81  
67.9 - 61.8  
Full load conditions  
Starting amperes  
Heating  
kW  
A
1
Indoor Unit  
Outdoor Unit  
Compressor  
230 - 208 V / 1 phase / 60 Hz 230 - 208 V / 1 phase / 60 Hz  
Complete Unit  
Fan Motor  
Fan Motor  
Performance at  
A
kW  
A
0.7 - 0.7  
0.16 - 0.14  
0.7 - 0.7  
0.16 - 0.14  
2 - 2  
0.9 - 0.9  
0.18 - 0.17  
0.9 - 0.9  
0.18 - 0.17  
1 - 1  
10.4 - 10.9  
2.31 - 2.24  
11.2 - 12.2  
2.49 - 2.47  
66 - 60  
12 - 12.5  
2.65 - 2.55  
12.8 - 13.8  
2.83 - 2.8  
67.7 - 61.7  
Rating conditions  
Full load conditions  
Starting amperes  
kW  
A
Cooling:  
Rating Conditions  
: Indoor Air Temperature  
80 °F DB / 67 °F WB  
Outdoor Air Temperature 95 °F DB  
Full Load Conditions : Indoor Air Temperature  
Outdoor Air Temperature 115 °F DB  
80 °F DB / 67 °F WB  
Heating:  
Rating Conditions  
: Indoor Air Temperature  
Outdoor Air Temperature 47 °F DB / 43 °F WB  
Full Load Conditions : Indoor Air Temperature  
70 °F DB / 60 °F WB  
80 °F DB / — °F WB  
Outdoor Air Temperature 45 °F DB / 35 °F WB  
SM830082  
I - 113  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor model: UH3642 / Outdoor model: CH3642  
Cooling  
Indoor Unit  
Outdoor Unit  
Fan Motor Compressor  
230 - 208 V / 1 phase / 60 Hz 230 - 208 V / 1 phase / 60 Hz  
Complete Unit  
Fan Motor  
Performance at  
A
kW  
A
1 - 1  
0.22 - 0.2  
1 - 1  
1.8 - 1.8  
0.36 - 0.34  
1.8 - 1.8  
0.36 - 0.34  
2 - 2  
12.3 - 13.7  
2.77 - 2.63  
15.4 - 16.8  
3.45 - 3.38  
95 - 86  
15.1 - 15.7  
Rating conditions  
3.35 - 3.17  
18.2 - 19.6  
4.03 - 3.92  
98 - 89  
Full load conditions  
Starting amperes  
Heating  
kW  
A
0.22 - 0.2  
2 - 2  
1
Indoor Unit  
Outdoor Unit  
Compressor  
230 - 208 V / 1 phase / 60 Hz 230 - 208 V / 1 phase / 60 Hz  
Complete Unit  
Fan Motor  
Fan Motor  
Performance at  
A
kW  
A
0.9 - 0.8  
0.21 - 0.18  
0.9 - 0.8  
0.21 - 0.18  
2 - 2  
1.8 - 1.8  
0.36 - 0.34  
1.8 - 1.8  
0.36 - 0.34  
2 - 2  
15.5 - 17  
3.21 - 3.24  
14.7 - 16  
3.32 - 3.29  
95 - 86  
18.2 - 19.6  
Rating conditions  
3.78 - 3.76  
17.4 - 18.6  
3.89 - 3.81  
97.9 - 88.8  
Full load conditions  
Starting amperes  
kW  
A
Cooling:  
Rating Conditions  
: Indoor Air Temperature  
80 °F DB / 67 °F WB  
Outdoor Air Temperature 95 °F DB  
Full Load Conditions : Indoor Air Temperature  
Outdoor Air Temperature 115 °F DB  
80 °F DB / 67 °F WB  
Heating:  
Rating Conditions  
: Indoor Air Temperature  
Outdoor Air Temperature 47 °F DB / 43 °F WB  
Full Load Conditions : Indoor Air Temperature  
70 °F DB / 60 °F WB  
80 °F DB / — °F WB  
Outdoor Air Temperature 45 °F DB / 35 °F WB  
SM830082  
I - 114  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor model: KH2442 / Outdoor model: CH2442  
Cooling  
Indoor Unit  
Outdoor Unit  
Fan Motor Compressor  
230 - 208 V / 1 phase / 60 Hz 230 - 208 V / 1 phase / 60 Hz  
Complete Unit  
Fan Motor  
Performance at  
A
kW  
A
0.4 - 0.4  
0.08 - 0.07  
0.4 - 0.4  
0.08 - 0.07  
1 - 1  
0.9 - 0.9  
0.18 - 0.17  
0.9 - 0.9  
0.18 - 0.17  
1 - 1  
9.0 - 9.6  
2.04 - 1.98  
11.0 - 11.7  
2.46 - 2.44  
66 - 60  
10.3 - 10.9  
Rating conditions  
2.30 - 2.22  
12.3 - 13.0  
2.72 - 2.68  
68 - 62  
Full load conditions  
Starting amperes  
Heating  
kW  
A
1
Indoor Unit  
Outdoor Unit  
Compressor  
230 - 208 V / 1 phase / 60 Hz 230 - 208 V / 1 phase / 60 Hz  
Complete Unit  
Fan Motor  
Fan Motor  
Performance at  
A
kW  
A
0.4 - 0.4  
0.08 - 0.07  
0.4 - 0.4  
0.08 - 0.07  
1 - 1  
0.9 - 0.9  
0.18 - 0.17  
0.9 - 0.9  
0.18 - 0.17  
1 - 1  
10.0 - 10.9  
2.24 - 2.19  
11.1 - 11.7  
2.52 - 2.44  
66 - 60  
11.3 - 12.2  
Rating conditions  
2.50 - 2.43  
12.4 - 13.0  
2.78 - 2.68  
68 - 62  
Full load conditions  
Starting amperes  
kW  
A
Cooling:  
Rating Conditions  
: Indoor Air Temperature  
80 °F DB / 67 °F WB  
Outdoor Air Temperature 95 °F DB  
Full Load Conditions : Indoor Air Temperature  
Outdoor Air Temperature 115 °F DB  
80 °F DB / 67 °F WB  
Heating:  
Rating Conditions  
: Indoor Air Temperature  
Outdoor Air Temperature 47 °F DB / 43 °F WB  
Full Load Conditions : Indoor Air Temperature  
70 °F DB / 60 °F WB  
80 °F DB / — °F WB  
Outdoor Air Temperature 45 °F DB / 35 °F WB  
SM830082  
I - 115  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Specifications  
Indoor model: KH3642 / Outdoor model: CH3642  
Cooling  
Indoor Unit  
Outdoor Unit  
Fan Motor Compressor  
230 - 208 V / 1 phase / 60 Hz 230 - 208 V / 1 phase / 60 Hz  
Complete Unit  
Fan Motor  
Performance at  
A
kW  
A
0.5 - 0.5  
0.10 - 0.09  
0.5 - 0.5  
0.10 - 0.09  
1 - 1  
1.8 - 1.8  
0.36 - 0.34  
1.8 - 1.8  
0.36 - 0.34  
2 - 2  
12.6 - 13.2  
2.83 - 2.69  
15.4 - 16.8  
3.45 - 3.38  
95 - 86  
14.9 - 15.5  
Rating conditions  
3.29 - 3.12  
17.7 - 19.1  
3.91 - 3.81  
97.5 - 88.5  
Full load conditions  
Starting amperes  
Heating  
kW  
A
1
Indoor Unit  
Outdoor Unit  
Compressor  
230 - 208 V / 1 phase / 60 Hz 230 - 208 V / 1 phase / 60 Hz  
Complete Unit  
Fan Motor  
Fan Motor  
Performance at  
A
kW  
A
0.5 - 0.5  
0.10 - 0.09  
0.5 - 0.5  
0.10 - 0.09  
1 - 1  
1.8 - 1.8  
0.36 - 0.34  
1.8 - 1.8  
0.36 - 0.34  
2 - 2  
15.5 - 16.8  
3.40 - 3.38  
14.7 - 16.0  
3.32 - 3.29  
95 - 86  
17.8 - 19.1  
Rating conditions  
3.86 - 3.81  
17 - 18.3  
Full load conditions  
Starting amperes  
kW  
A
3.78 - 3.72  
97.5 - 88.5  
Cooling:  
Rating Conditions  
: Indoor Air Temperature  
80 °F DB / 67 °F WB  
Outdoor Air Temperature 95 °F DB  
Full Load Conditions : Indoor Air Temperature  
Outdoor Air Temperature 115 °F DB  
80 °F DB / 67 °F WB  
Heating:  
Rating Conditions  
: Indoor Air Temperature  
Outdoor Air Temperature 47 °F DB / 43 °F WB  
Full Load Conditions : Indoor Air Temperature  
70 °F DB / 60 °F WB  
80 °F DB / — °F WB  
Outdoor Air Temperature 45 °F DB / 35 °F WB  
SM830082  
I - 116  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. PROCESSES AND FUNCTIONS  
2-1 Room Temperature Control ...................................................................... II - 2  
(A)Cooling ................................................................................................ II - 2  
(B)Heating ................................................................................................ II - 3  
2-2 Cold Draft Prevention (Heating Cycle)...................................................... II - 4  
2-3 Automatic Fan Speed (Indoor Unit) .......................................................... II - 5  
(A)Cooling ................................................................................................ II - 5  
(B)Heating ................................................................................................ II - 5  
2-4 Outdoor Fan Speed Control...................................................................... II - 6  
(A)Cooling ................................................................................................ II - 6  
(B)Heating ................................................................................................ II - 6  
2-5 Freeze Prevention (Cooling)..................................................................... II - 7  
2-6 Condensing Temperature Control (Cooling)............................................. II - 8  
2-7 Overload Protection (Heating) .................................................................. II - 9  
2-8 Discharge Temperature Control (Cooling and Heating) ........................... II -10  
2-9 Auto. Mode for Automatic Heating/Cooling Switching .............................. II -11  
2-10 Defrosting Control, Outdoor Heat Exchanger Coil (Heating) .................... II -13  
2-11 4-Way Valve, Solenoid Control ................................................................. II -14  
(A) Normal Control Mode.......................................................................... II -14  
(B) AUTO Control Mode ........................................................................... II -15  
2-12 Automatic Restart after Power Interruption............................................... II -15  
2-13 Electronic Refrigerant Control Valve......................................................... II -16  
2-14 Compressor Discharge Gas Temperature................................................ II -16  
(A)Cooling ................................................................................................ II -16  
(B)Heating (Except During Defrosting) ..................................................... II -16  
2-15 Compressor Current Detection Circuit...................................................... II -17  
2-16 Electronic Refrigerant Control Valve Control ............................................ II -18  
2-17 Voltage Detection Control......................................................................... II -19  
n  
2
SM830082  
II - 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Processes and functions  
2-1 Room Temperature Control  
The Unit adjusts room temperature by turning the outdoor unit’s compressor ON and OFF.  
This process is controlled by the thermostat located in the remote control unit.  
The figures on this and the next pages show how each part of the system performs when the  
room temperature changes and the thermostat activates the compressor to start (thermo ON)  
or stop (thermo OFF). Fig. 1 shows about the cooling cycle, and Fig. 2 shows about the  
heating cycle.  
(A) Cooling  
(THERMO. OFF)  
THERMO. OFF  
(THERMO. ON)  
ROOM TEMP.  
THERMO. ON  
BODY SENSOR  
T+2 °F  
SET TEMP. T °F  
T–2 °F  
S
MORE THAN  
5 MINUTES  
MORE THAN  
3 MINUTES  
MORE THAN  
5 MINUTES  
3 MINUTES  
OFF  
5 MINUTES  
ON  
COMPRESSOR  
1
OUTDOOR FAN  
(H OR M)  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
ON  
2
SET SPEED  
1. Refer to 2-4 Outdoor Fan Speed Control  
INDOOR FAN  
1133_THS_I  
Fig. 1  
Chart Summary and Explanations  
Once the compressor starts, it keeps running for 5 minutes.  
Once the compressor stops, it will not start running again for 3 minutes.  
If you change the operation mode (HEAT, COOL, or FAN) during the cooling cycle, the  
control circuit stops the compressor for 3 minutes.  
For 5 minutes after the compressor is first turned on, and for 3 minutes after it is turned off,  
the compressor is not controlled by the room sensor.  
Thermo ON: When room temperature rises 2°F (4°F when set on body sensor) above  
the set temperature T˚, (T˚+2°F or T˚+4°F when set on body sensor):  
Compressor ON  
Thermo OFF: When the room temperature is –2°F below the set temperature T˚:  
Compressor OFF  
SM830082  
II - 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Processes and functions  
(B) Heating  
THERMO. ON  
THERMO. ON  
REMOTE CONTROL  
SENSOR  
THERMO. OFF  
THERMO. OFF  
THERMO. ON  
(Only for wireless  
remote controller)  
SET. +2°F  
SETTING TEMP.  
SET. –2°F  
THERMO. OFF  
THERMO. OFF  
THERMO. ON  
BODY SENSOR  
THERMO. ON  
THERMO. ON  
+2°F  
SET TEMP.+7°F SHIFT  
–2°F  
SET TEMP.  
MORE THAN  
3 MINUTES  
MORE THAN  
5 MINUTES  
5 MINUTES  
ON  
3 MINUTES  
OFF  
n  
OFF  
OFF  
OFF  
ON  
OFF  
OFF  
ON  
COMPRESSOR  
1
OUTDOOR FAN  
(H OR M)  
ON  
OFF  
ON  
ON  
3 SECONDS  
2
SET SPEED  
SET SPEED  
OFF  
SET SPEED  
OFF  
LL  
LL  
L
L
LL  
INDOOR FAN  
2
OFF ON  
ON  
ON  
OFF  
STANDBY  
(88°F)  
INDOOR HEAT  
EXCH.  
2
COIL  
TEMP.  
81°F  
77°F  
E2  
SOLENOID  
COIL (4-WAY)  
TEMP.  
ON (REVERSING CYCLE)  
ON  
OPERATION  
BUTTON  
OFF  
1. Refer to 2-4 Outdoor Fan Speed Control  
2. Refer to 2-2 Cold Draft Prevention (Heating)  
1134_THS_I  
Fig. 2  
Chart Summary and Explanations  
Once the compressor starts, it keeps running for 5 minutes.  
Once the compressor stops, it will not start running again for 3 minutes.  
If you change the operation mode (HEAT, COOL or FAN) during the heating cycle, the  
control circuit stops the compressor for 3 minutes.  
For 5 minutes after the compressor is first turned on, and for 3 minutes after it is turned off,  
the compressor is not controlled by the room sensor.  
When set on remote control sensor  
Thermo ON: When room temperature is –2°F below the set temperature T˚.  
Compressor ON  
Thermo OFF: When the room temperature is 2°F above the set temperature T˚, (T˚+2°F)  
Compressor OFF  
When set on body sensor  
NOTE: In case of Body sensor, operating temperature is shifted to setting temperature +7°F.  
SM830082  
II - 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Processes and functions  
2-2 Cold Draft Prevention (Heating Cycle)  
The cold draft prevention function controls indoor fan speed so a strong draft of cold air will  
not blow out before the indoor heat exchange coils have warmed up.  
STANDBY shows on the remote controller when the indoor fan speed is LL (very  
low) or OFF. This condition occurs in the following 3 cases:  
• During Thermo OFF (refer to 2-1 B). Room Temperature Control, Heating)  
• During the defrosting operation (refer to 2-10 Defrosting Control, Heating)  
• Until either the coil temperature E2 reaches 81°F or when a maximum of 6 minutes  
has past.  
The indoor fan motor operates in L instead of LL for 3 seconds as it starts to give  
the fan an initial boost.  
S
92  
MAX. 6 MINUTES  
88  
INDOOR UNIT  
COIL TEMP.  
E2 (°F)  
81  
77  
2
50  
AUTO OR H LL  
LL/OFF  
LL/OFF  
LL/OFF  
LL  
LL  
LL  
L
L
L
M
M
L
H
M
L
SET  
FAN  
M
L
LL  
LL  
SPEED  
“STANDBY”  
INDICATOR  
“STANDBY” APPEARS  
LL= Very low speed  
L= Low speed  
M= Medium speed  
H= High speed  
1135_THS_I  
Fig. 3  
Chart Summary and Explanations  
The main idea of this chart is to show that the indoor fan speed increases and gets closer to  
the set fan speed as the coil temperature E2 rises.  
The indoor unit’s coil temperature is taken from sensor E2 located in the middle of the indoor  
heat exchange coil.  
The dotted line shows that the indoor fan motor is OFF. When the temperature at sensor E2  
falls below 50°F, the indoor fan motor stops running.  
SM830082  
II - 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Processes and functions  
2-3 Automatic Fan Speed (Indoor Unit)  
By pressing the FAN SPEED button on the remote controller, the fan speed can be set at  
one of four steps: AUTO., HI., MED., or LO. When set at AUTO. the indoor unit fan speed  
will be automatically adjusted to the room temperature as the two charts shown below.  
(A) Cooling  
ROOM TEMP.  
(deg)  
+3  
+2  
+1  
SET TEMP.  
n  
INDOOR FAN  
H
H
SPEED  
M
M
L
H : High  
M: Middle  
L : Low  
1923_M_S  
Fig. 4  
Chart Explanations and notes  
When the fan speed changes, it keeps the speed step for at least 3 minutes, even if the  
temperature changes to another speed step during the time.  
2
(B) Heating  
ROOM TEMP.  
(deg)  
SET TEMP.  
–2  
–4  
INDOOR FAN  
H
SPEED  
H
M
M
L
H : High  
M : Middle  
L : Low  
1924_M_S  
Fig. 5  
Chart Explanations and notes  
When the fan speed changes, it keeps the speed step for at least 1 minute, even if the  
temperature changes to another speed step during the time.  
SM830082  
II - 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Processes and functions  
2-4 Outdoor Fan Speed Control  
To optimize the performance of air conditioner, the outdoor fan speed is selected  
automatically according to the outdoor temperature.  
Note that in both Cooling and Heating modes, the fan comes on at first at high  
speed (H mode) for 5 seconds. Since outdoor conditions sometimes make it  
difficult for the fan to start, this sudden surge of power may be necessary.  
The outdoor fan operates in H mode for 3 minutes after the compressor stops  
(excluding defrosting operation period).  
Charts below show how the outdoor fan speed changes with the change in  
outdoor temperature.  
S
(A) Cooling  
Outdoor unit coil  
temperature [C2]  
Outdoor fan  
motor (FMo)  
H
or more 77°F  
H
M
L
77  
32  
32°F or more, less than 77°F  
less than 32°F  
M
L
2
Fig. 6  
(B) Heating  
Outdoor coil  
temperature [C2]  
Outdoor fan  
motor (FMo)  
M
or more 57°F  
less than 57°F  
M
H
57  
H
Fig. 7  
SM830082  
II - 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Processes and functions  
2-5 Freeze Prevention (Cooling)  
Freeze Prevention keeps the indoor heat exchange coil from freezing. Freezing reduces the  
efficiency of the unit, and frost build up on the coil blocks cool air circulation from the indoor  
unit's fan.  
MIN. VALUE OF  
EITHER E1 OR E2  
INDOOR UNIT  
TEMP.  
34  
33  
32  
31  
n  
CONTINUOUS  
DETECTION  
FOR 2 MINUTES  
(°F)  
ELECTRONIC REF.  
CONTROL  
VALVE SIGNAL  
OPEN  
OPEN  
COMPRESSOR  
MINIMUM 3  
MINUTES  
ON  
ON  
1925_THS_I  
2
Fig. 8  
Note: Freeze prevention is controlled by the temperature at the indoor heat  
exchanger coil as sensed by either sensor E1 (located at the entrance  
of the coil) or sensor E2 (located on the middle of the coil). Freeze  
prevention cycle is controlled by the lower temperature sensed at either  
of the two sensors.  
Chart Explanations and notes  
This chart shows when the electronic refrigerant control valve opens to regulate the  
temperature of the indoor unit coil to prevent freezing.  
If the refrigerant control is not effective and the temperature continues to drop and stays  
below 31°F for 2 minutes continuously, the control circuit stops the compressor. The  
compressor does not start again until the temperature rises above 34°F.  
The compressor stops for 3 minutes minimum.  
SM830082  
II - 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Processes and functions  
2-6 Condensing Temperature Control (Cooling)  
Condensing temperature is controlled by the outdoor heat exchanger coil temperature as  
sensed by sensor C2.  
140  
OUTDOOR UNIT  
COIL TEMP. C2  
(°F)  
131  
OUTDOOR FAN  
FORCED  
SPEED  
H, M or L  
H, M or L  
H
S
ELECTRONIC REF.  
CONTROL VALVE  
OPEN  
1926_THS_I  
Fig. 9  
Chart Explanations and notes  
2
This chart shows how the outdoor fan speed and the electronic refrigerant control valve  
react to coil temperature to control condensing temperature.  
Sensor C2 is located in the middle of the outdoor unit heat exchange coil.  
When C2 rises above 140°F the electronic refrigerant control valve opens at 50 steps/30  
seconds, and the outdoor fan speed is forced to change to high (H) until C2 falls below  
131°F.  
SM830082  
II - 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Processes and functions  
2-7 Overload Protection (Heating)  
This function prevents the air conditioner from overloading.  
(°F)  
147  
144  
140  
INDOOR UNIT COIL  
TEMP. (E2)  
138  
131  
127  
OVERLOAD  
PROTECTION  
OVERLOAD PROTECTION  
n  
FUZZY CONTROL  
FUZZY CONTROL  
ELECTRONIC REF.  
CONTROL VALVE  
OPEN  
OPEN  
START UP  
COMPENSATION  
OFF  
OUTDOOR FM  
H OR M  
H
L
H OR M  
1927_THS_I  
2
Fig. 10  
Chart Explanations and notes  
This chart shows how the outdoor fan speed and the electronic refrigerant control valve  
react to coil temperature to keep the indoor heat exchanger coil from overloading.  
When sensor E2 rises above 140°F the electronic refrigerant control valve opens at 50  
steps/30 seconds until E2 falls below 138°F.  
Sensor E2 is located in the middle of the indoor unit heat exchange unit.  
When sensor E2 rises above 144°F, the control circuit stops the outdoor fan motor till the  
temp. drops to 131°F  
Fuzzy control controls the electronic refrigerant control valve.  
SM830082  
II - 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Processes and functions  
2-8 Discharge Temperature Control (Cooling and Heating)  
This function prevents the compressor motor from burnout by overheating.  
(42 Type) (24, 36 Type)  
275  
239  
257  
239  
221  
203  
235  
230  
221  
200  
194  
185  
DISCHARGE GAS  
TEMP. (°F)  
S
OUTDOOR  
FAN SPEED  
H OR M  
H OR M  
L
COMPRESSOR  
ON  
ELECTRONIC REF.  
CONTROL VALVE  
(DISCHARGE TEMP.)  
OPEN  
OPEN  
TRIP IS OPERATED.  
2
1928_THS_I  
Fig. 11  
Chart Summary and Explanations  
Discharge temperature is sensed by TH8 (discharge gas sensor).  
When the temperature rises above 203°F (24, 36 Type) the electronic refrigerant control  
valve opens at 50 steps/30 seconds until the temperature falls below 200°F (24, 36 Type) .  
During HEATING operation, when the temperature rises above 221°F (24, 36 Type), the  
control circuit stops the outdoor fan motor until the temperature falls below 194°F (24, 36  
Type). Please note that this control does not function during COOLING operation.  
For both COOLING and HEATING modes, if the temperature reaches 239°F (24, 36 Type)  
the operation shuts down and alarm P3 appears on the remote controller.  
The outdoor fan speed is controlled on discharge temp. at heating mode.  
SM830082  
II - 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Processes and functions  
2-9 Auto. Mode for Automatic Heating/Cooling Switching  
When the AUTO mode is selected, the microprocessor calculates the difference  
between the set temperature and the room temperature, and automatically switches  
to the COOLING or HEATING mode to maintain the desired temperature.  
Room temp. ] Set temp. COOLING  
Room temp. < Set temp. HEATING  
This means that if the room temperature is higher or equal to the set temperature,  
COOLING operation starts. If the room temperature is lower than the set  
temperature, HEATING operation starts.  
A
COOLING SELECTION TEMP.  
+5 deg  
n  
SHIFT SET TEMP.  
+4 deg  
REMOTE CONTROLLED  
B
SET TEMP.  
SHIFT SET TEMP.  
–4 deg  
HEATING SELECTION TEMP.  
–6 deg  
2
C
HEATING  
COOLING  
HEATING  
1142_THS_I  
Fig. 12  
SM830082  
II - 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Processes and functions  
Chart summary and Explanations  
This chart shows how the Operation Mode (COOLING or HEATING) is determined by the  
microprocessor taking the room temperature into consideration. It also shows the  
temperature points at which the cooling or heating mode is switched, when the AUTO mode  
is selected.  
After operation starts, the set temperature shifts automatically by +4 deg. at cooling and  
by -4 deg. at heating. For example, if cooling is selected, the set temperature changes from  
68°F to 72°F.  
(The display of the remote controller remains 68°F.)  
The change of the operation mode (heating to cooling, cooling to heating) by the change of  
the room temperature during the operation is as follows.  
Heating to Cooling; Room temp. Shifted temp +1.0 deg.  
Cooling to Heating; Room temp. Shifted temp -2.0deg.  
For example, if the room temperature rises above 73°F (=72+1) during the cooling  
operation at the room temperature 68°F set by the remote controller, the operation changes  
to cooling. When the room temperature lowers below 63°F (=65-2) thereafter, the operation  
changes to heating again.  
S
In heating operation, using the body sensor, room temperature control is designed so that  
room air temp. is sensed as 8 deg. lower than suctioned air at indoor unit taking into  
account of the temperature gap between upper part and lower part of the room.  
Within 10 minutes after the compressor turns OFF, the operation does not change to  
cooling (heating), even when the room temperature changes from C to A (A to C).  
When switching from cooling (heating) to heating (cooling), the actuation of the 4 way valve  
will delay about 30-50 seconds after the compressor turns ON.  
2
SM830082  
II - 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Processes and functions  
2-10 Defrosting Control, Outdoor Heat Exchanger Coil (Heating)  
When the outdoor temperature is low, frost may form on the outdoor heat exchanger coil.  
When this occurred, the defrosting system operates. The microprocessor in the outdoor unit  
monitors the relationship between the temperature of the outdoor heat exchanger coil and the  
outdoor temperature so it can defrost when necessary.  
Flow of Defrosting  
OUTDOOR COIL  
TEMP. C1 (°F)  
Y
“RELEASE OF  
DEFROSTING”  
RANGE  
Heating operation  
50  
OUTDOOR AIR TEMP.  
(°F)  
X
No counting time for detecting  
frost : 15 minutes  
7.3  
50  
27  
18  
n  
The area below the heavy line  
is the frost detection area.  
Detecting the frost  
–4  
Stand by time for defros:  
25 minutes  
Either continuous 8 minutes or cumulative 60 minutes  
are required to detect frost in the “Frosting” range.  
Defrosting  
Refer to time chart.  
*Minimum continuous operating time by defrosting is 48 minutes (= 15 + 8 + 25).  
2
Occurs either when the temperature of C1 (the outdoor  
heat exchanger coil) has reached 50°F or above,  
or when the maximum defrosting time (9 minutes)  
has elapsed.  
Release of defrosting  
1143_THS_I  
Fig. 13  
Time Chart for Defrosting  
1 MINUTE  
ON  
MAX. 9 MINUTES  
ON  
1 MINUTE  
ON  
COMPRESSOR  
SOLENOID COIL  
(4 WAY VALVE)  
ON  
ON  
ON  
ON  
OUTDOOR FAN  
(H OR L)  
INDOOR FAN  
(SET SPEED)  
OFF  
OR LL  
OFF OR LL  
“STANDBY”  
INDICATOR  
“STANDBY” APPEARS  
Defrosting  
Start  
Release of  
Defrosting  
0442_M_S  
Fig. 14  
During the defrost cycle, STANDBY appears on the remote controller.  
*......Cold Draft Prevention may operate occasionally  
SM830082  
II - 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Processes and functions  
2-11 4-Way Valve, Solenoid Control  
The basic function of the 4-way valve is to direct the refrigerant in the correct direction  
according to the Operation Mode (COOLING or HEATING) selected.  
The following two charts show conditions of the controls and functions listed in the left hand  
column when the solenoid is ON or OFF. Chart (A) on this page shows the relationships when  
the temperature control is in NORMAL mode, and Chart (B) on the next page shows the  
relationships when the remote controller is set to AUTO mode.  
(A) Normal Control Mode  
OFF  
ON  
POWER SOURCE  
S
OPERATION  
BUTTON  
ON  
OFF  
ON  
COOL  
COOL  
MODE  
BUTTON  
HEAT  
HEAT  
HEAT  
2
3 MINUTES  
ON  
TURN ON  
THERMO OFF  
THERMO OFF  
THERMO  
ON  
TURN OFF  
THERMO  
ON  
2
OFF  
ON  
1
OFF  
2
ON  
OFF  
2
ON  
COMPRESSOR  
1
1
1
SOLENOID COIL  
(4-WAY VALVE)  
OFF  
ON  
OFF  
ON  
1. . . More than 5 minutes  
2. . . More than 3 minutes  
0443_M_S  
Fig. 15  
Chart Summary and Explanations  
For the first 3 minutes after power is applied, the 4–way valve remains OFF and the  
compressor will not operate, even if the ON button is pushed.  
If the 4–way valve is turned OFF with the compressor operating, the air conditioner  
operates in COOLING mode. See Table below.  
If the 4–way valve is turned ON with the compressor operating, the air conditioner operates  
in HEATING mode. See Table below.  
4-way valve  
solenoid  
Operation Mode  
Compressor  
ON  
COOLING  
HEATING  
OFF  
ON  
SM830082  
II - 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Processes and functions  
(B) AUTO Control Mode  
POWER SOURCE OFF  
ON  
OPERATION  
BUTTON  
ON  
MORE THAN 10 MINUTES MORE THAN 10 MINUTES  
(THERMO. OFF) (THERMO. OFF)  
AUTO  
COOL  
COOL  
MODE  
CONTROL HEAT  
HEAT  
HEAT  
THERMO. OFF  
THERMO. ON  
3 MINUTES  
MORE THAN  
3 MINUTES  
OFF  
COMPRESSOR  
OFF  
OFF  
ON  
OFF  
MORE THAN  
ON  
OFF  
ON  
ON  
n  
MORE THAN  
30 – 50 SECONDS  
30 – 50 SECONDS  
SOLENOID COIL  
(4-WAY VALVE)  
ON  
OFF  
ON  
0445_M_S  
Fig. 16  
When the Compressor has stopped while in AUTO mode, the 4-way valve switches on  
(heating) or off (cooling) within 1 minute according to the following conditions:  
2
Compressor has stopped  
under the operation of  
“AUTO mode” condition.  
4-way valve delays its  
switching for 30 – 50 seconds  
after compressor has been  
turned ON.  
0446_M_S  
Fig. 17  
2-12 Automatic Restart after Power Interruption  
This air conditionner has a power failure recovery function.  
SM830082  
II - 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Processes and functions  
2-13 Electronic Refrigerant Control Valve  
This valve allows very precise and smooth control of the amount of refrigerant flow in the  
system. Since the valve is operated by a step motor, the control circuits can open or  
close it in very exact amounts, so the degree of heating or cooling can be changed by  
just a little, or changed very quickly or slowly.  
(Completely close …… 0 step)  
(Full open................ 480 step)  
Min. open  
Max. open  
Model  
HEAT  
100 step  
90 step  
100 step  
COOL  
100 step  
90 step  
24 type  
36 type  
42 type  
480 step  
100 step  
S
Fuzzy Control  
Fuzzy Control is a controlling system to control electronic refrigerant control valve using  
fuzzy logic. It regulates the functions of heating and cooling, as well as some of the  
processes inside the unit, by taking account of many different conditions of temperature,  
fan speed, etc. These control circuits work automatically to send just the right amount of  
refrigerant through the Electronic Refrigerant Control Valve.  
2-14 Compressor Discharge Gas Temperature  
2
(A) Cooling  
Indoor temp. (°F)  
68 – 77  
79 – 82  
81 – 95  
84 – 90  
Outdoor temp. (°F)  
55 or below  
104 – 176  
57 – 61  
97 – 109  
Compressor discharge  
gas temp. (°F)  
104 – 194  
140 – 212  
158 – 221  
(B) Heating (Except During Defrosting)  
Indoor temp. (°F)  
64 – 70  
72 – 77  
79 – 86  
Outdoor temp. (°F)  
32 or below 34 – 50 32 or below 34 – 50 52 – 70 32 or below 34 – 50 52 – 70  
Compressor discharge  
gas temp. (°F)  
104 – 176 122 – 194 122 – 194 122 – 212 140 – 221 122 – 194 140 – 212 158 – 221  
Operate the unit at least 30 minutes to stabilize the discharge temperature.  
The above discharge temperature was measured with a 15m tubing length.  
The temperature may vary with tubing length.  
SM830082  
II - 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Processes and functions  
2-15 Compressor Current Detection Circuit  
The Compressor Current Detection Circuit detects the compressor current and,  
depending on the current range, can stop the compressor motor so it will not be  
damaged by overcurrent.  
Overcurrent can be caused by several factors, particularly mechanical seizing of the  
compressor or liquid backflow. Either of these conditions can hold the compressor  
to run, and thus drawing so much current that the motor can burn out.  
Comp. Amps.(A)  
Locked Comp. Cut-off Range  
Is  
1.4  
+
Overload Protection Range  
Normal Operation Range  
Is  
1.17  
+
Is  
n  
Rated Current  
value  
0447_M_S  
Fig. 18  
Rated Current Value  
Overload Protection  
Locked Compressor Cut-off  
Is x 1.4 (A)  
Outdoor Model  
ls (A)  
ls x 1.17 (A)  
CH2442  
CH3642  
CH4242  
17.1  
20.0  
23.9  
38.5  
48.6  
27.5  
34.7  
32.2  
40.6  
2
Chart Summary and Explanations  
Overload Protection  
When the detected current is 1.17 – 1.4 times greater than the rated current value (Is) and continues  
for 30 seconds, both compressor and outdoor fan stop (Thermostat OFF).  
After 3-minute pause, if the air conditioner is ready for Thermostat ON, it starts again. However, if the  
condition mentioned above repeats twice within 30 minutes, the remote controller displays the alarm  
message H01, compressor overload.  
Locked Compressor Cut-off  
When the detected current is 1.4 times greater than the rated current value (ls) and continues for 2  
seconds, both compressor and outdoor fan stop (Thermostat OFF).  
After 3-minute pause, if the air conditioner is ready for Thermostat ON, it starts again. However, if the  
condition mentioned above repeats twice, the remote controller displays the alarm message H02,  
compressor locked.  
Failure of Compressor Current Detection  
When the Compressor Current Detection Circuit fails to detect the compressor current within 2  
seconds after compressor starts, both compressor and outdoor fan stop (Thermostat OFF).  
After 3-minute pause, if the air conditioner is ready for Thermostat ON, it starts again. However, when  
the circuit fails to detect the current twice in a row, the remote controller displays alarm message H03,  
Failure of compressor Current Detection.  
SM830082  
II - 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Processes and functions  
2-16 Electronic Refrigerant Control Valve Control  
The circulation volume of the refrigerant is controlled by a pulse type electronic control valve.  
When the power is switched ON, the opening degree of the electronic control valve is  
controlled between 90 and 480 steps after setting the initial step at the time when the  
thermostat is ON.  
Contents and Order of control  
Cooling  
Heating  
Start  
Start  
Discharge gas temperature control  
Outdoor unit coil temperature control  
Freeze prevention control  
Discharge gas temperature control  
High load prevention control  
Heating start up control  
S
Refrigerant flow distribution control  
Refrigerant flow distribution control  
Discharge gas target temperature  
control (Fuzzy control)  
Discharge gas target temperature  
control (Fuzzy control)  
*
*
2
0451_M_S  
Repeat control in accordance with the priority order.  
*
Even though the operation is performed every 30 seconds, the control of discharge gas  
temperature, high load prevention, outdoor unit coil temperature and freeze prevention  
activates when it occurs.  
(1) Refrigerant flow distribution control  
At the control of flexible combination (a plural number of indoor units are set), the opening  
degree of the electronic control valve is controlled by the indoor unit coil temperature.  
Cooling: indoor unit coil E2 temperature (located at the middle of coil)  
Heating: indoor unit coil E1 temperature (located at the outlet of coil)  
(2) Fuzzy control (optimal refrigerant flow rate control)  
By outputting the fuzzy estimation result corresponding to the fuzzy input variables (the indoor  
unit coil temp., the deviation between the actual discharge gas temp. and the target discharge  
gas temperature calculated from the outdoor unit coil temperature and the change thereof),  
the electronic refrigerant valve is controlled so that the unit can perform its maximum ability in  
accordance with the indoor and outdoor temperature conditions at the operation.  
SM830082  
II - 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Processes and functions  
2-17 Voltage Detection Control  
When the power voltage falls below 160 V or rises above 260 V, operation lamp and stand-by  
lamp flash alternately to protect the compressor and electrical components.  
n  
2
SM830082  
II - 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. ELECTRICAL DATA  
3-1 Indoor Units (Electric Wiring Diagram, Schematic Diagram) .................. III - 2  
4-Way Air Discharge Semi-concealed Type .......................................... III - 2  
Ceiling Mounted Type............................................................................. III - 4  
Concealed Duct Type ............................................................................. III - 6  
Concealed Duct High Static Pressure Type ........................................... III - 8  
3-2 Outdoor Units (Electric Wiring Diagram, Schematic Diagram) ............... III - 12  
3
SM830082  
III - 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Electrical data  
3-1 Indoor Units  
4-Way Air Discharge Semi-concealed Type : XH2442, XH3642, XH4242  
G R N / Y E L  
G R N / Y E L  
B L K  
G R Y  
B L K  
G R Y  
G R N / Y E L  
R E D  
R E D  
G R N / Y E L  
G R Y  
P N K  
G R Y  
P N K  
B R N  
B R N  
O R G  
G R Y  
B L K  
Y E L  
R E D  
O R G  
G R Y  
G R Y  
G R Y  
G R Y  
W H T  
V L T  
O R G  
Y E L  
B L K  
B R N  
P N K  
O R G  
Y E L  
B L K  
B R N  
P N K  
B L K  
B L K  
B R N  
3
B L K  
B L K  
O R G  
O R G  
R E D  
R E D  
B R N  
B R N  
B L K  
B L K  
W H T  
W H T  
B L K  
B L K  
B L K  
W H T  
B L U  
P N K  
G R N / Y E L  
B R N  
R E D  
SM830082  
III - 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Electrical data  
4-Way Air Discharge Semi-concealed Type : XH2442, XH3642, XH4242  
• Schematic Diagram  
CR  
CN2  
1
3
1
3
1
2
3
4
5
6
RC  
WL  
TH  
RCU  
T10  
1
2
3
4
F1(5A)  
T20  
5P-1  
5P-2  
1
1
TR1  
1
2
3
4
1
2
3
4
5
6
1X  
8
T6  
MOV  
VCC  
5
2X  
3X  
RY2  
RY1  
RY4  
49FI  
LSW  
1
3
1
2
LS  
1
3
9
3
RS2  
FS  
1
2
3
PNL  
1
3
DP  
LM  
26H  
FM  
Room Thermistor  
FS  
1
2
1
2
1
2
1
3
1
3
4
5
5
7
1
1
1
1
Room  
Temp  
TH1  
E1  
Indoor Coil  
Indoor Coil  
Indoor Coil  
Coil  
E1  
TH2  
E2  
3
6
7
Coil  
E2  
LL  
L
H
HH HT  
TH3  
E3  
Coil  
E3  
TH4  
FMI  
1X  
DP  
LM  
2
2X  
3X  
1
2
RY1  
RY4  
RC1  
RY2  
1
2
OC  
3
9
3
3
3
DC12V  
5P-  
U2  
5P-  
U1  
F2(5A)  
3
To Outdoor Unit  
Symbols  
Description  
Symbols  
Description  
FMI  
MOV  
49FI  
RC1  
TR1  
DP  
Indoor Fan Motor  
1X~3X  
RY1, 2, 3  
CR  
Auxiliary Relay  
Motor Operated Valve  
Indoor Motor Thermal Protector  
Running Capacitor  
Power Transformer  
Drain Pump  
Indoor Controller  
Limit Switch  
LSW  
LM  
Auto Louver Motor  
(RCU)  
Remote Control Unit  
(Optional Parts)  
FS  
Float Switch  
TH1  
TH2  
TH3  
TH4  
F1, 2  
Room Thermistor  
(TH)  
Room Thermistor  
Terminal Plate  
Connector  
Thermistor (Indoor Coil E1)  
Thermistor (Indoor Coil E2)  
Thermistor (Indoor Coil E3)  
Fuse  
Terminal  
S 854-2-5268-930-00-1 (X)  
SM830082  
III - 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Electrical data  
Ceiling Mounted Type : TH2442, TH3642, TH4242  
G R Y  
B L K  
Y E L  
R E D  
O R G  
G R N / Y E L  
2 P ( W H T )  
C o n n e c t e r  
W H T  
B L U  
G R Y  
P N K  
G R N / Y E L  
B R N  
B R N  
B L K  
B L K  
B L K  
B L K  
B L K  
B L K  
G R Y  
G R Y  
G R Y  
G R Y  
W H T  
V L T  
B L K  
B L K  
O R G  
Y E L  
B L K  
B R N  
P N K  
O R G  
Y E L  
B L K  
B R N  
P N K  
B R N  
2 P ( B L K )  
C o n n e c t e r  
B L K  
B L K  
B L K  
3
O R G  
O R G  
R E D  
R E D  
B R N  
B R N  
W H T  
W H T  
O R G  
B L K  
W H T  
B L U  
P N K  
T n a l  
E a
G R N / Y E L  
B R N  
R E D  
SM830082  
III - 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Electrical data  
Ceiling Mounted Type : TH2442, TH3642, TH4242  
• Schematic Diagram  
CR  
CN2  
1
1
3
1
2
3
4
5
6
RC  
WL  
3
TH  
RCU  
T10  
1
2
3
4
F1(5A)  
T20  
5P-1  
5P-2  
1
1
SUP  
TR1  
1
2
3
4
5
6
1X  
8
1
2
3
4
VCC  
2X  
RY1  
RY2  
RY4  
49FI  
T6  
LS  
MOV  
5
1
3
9
3
RS2  
FS  
3X  
1
3
LSW  
1
2
1
3
LM  
DP  
26H  
LL  
1
L
H
HH  
Room Thermistor  
1
2
1
2
1
2
1
3
3
5
5
7
1
1
1
1
Room  
Temp  
1
TH1  
E1  
Indoor Coil  
Indoor Coil  
Indoor Coil  
PNL  
2
3
Coil  
E1  
TH2  
E2  
3
4
6
7
Coil  
E2  
LL  
L
H
HH HT  
TH3  
E3  
Coil  
E3  
TH4  
FMI  
1X  
LM  
DP  
2
2X  
3X  
1
2
RY1  
RY4  
RC1  
RY2  
1
2
OC  
3
9
3
3
3
DC12V  
5P-  
U2  
5P-  
U1  
F2 (5A)  
3
To Outdoor Unit  
Symbols  
Description  
Symbols  
Description  
FMI  
Indoor Fan Motor  
TH2  
TH3  
TH4  
CR  
Thermistor (Indoor Coil E1)  
Thermistor (Indoor Coil E2)  
Thermistor (Indoor Coil E3)  
Indoor Controller  
49FI  
RC1  
F1, 2  
LM  
Indoor Motor Thermal Protector  
Running Capacitor  
Fuse  
Auto Louver Motor  
Power Transformer  
Auxiliary Relay  
(RCU)  
Remote Control Unit  
(Optional Parts)  
TR1  
1X~3X  
RY1, 2, 4  
MOV  
FS  
(TH)  
Room Thermistor  
Terminal Plate  
Connector  
Auxiliary Relay  
Motor Operated Valve  
Float Switch  
Terminal  
LSW  
TH1  
Limit Switch  
Room Thermistor  
S 854-2-5268-923-00-1 (T)  
SM830082  
III - 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Electrical data  
Concealed Duct Type : UH2442, UH3642  
G R N / Y E L  
R E D  
R E D  
B L K  
B L K  
G R Y  
B L K  
Y E L  
R E D  
O R G  
B L K  
B L K  
B L K  
B L K  
B L K  
B L K  
B L K  
B L K  
9 P ( W H T )  
C o n n e c t e r  
G R Y  
G R Y  
G R Y  
G R Y  
W H T  
V L T  
O R G  
Y E L  
B L K  
B R N  
P N K  
V L T  
O R G  
Y E L  
B L K  
3
O R G  
P N K  
B R N  
B R N  
G R N  
O R G  
O R G  
R E D  
R E D  
B R N  
B R N  
W H T  
W H T  
2 P ( B L U )  
C o n n e c t e r  
B L K  
W H T  
B L U  
P N K  
G R N / Y E L  
W H T  
R E D  
SM830082  
III - 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Electrical data  
Concealed Duct Type : UH2442, UH3642  
• Schematic Diagram  
CR  
CN2  
1
1
3
1
2
3
4
5
6
RC  
WL  
2
TH  
RCU  
T10  
Terminal  
Plate (5P)  
1
2
3
4
F1(5A)  
T20  
-1  
-2  
1
1
RS1  
TR1  
8
1X  
1
2
3
4
5
6
1
2
3
4
VCC  
RS2  
2X  
3X  
RY2  
49FI  
T6  
FS  
MOV  
5
1
3
9
3
1
3
FS  
DP  
FM  
1
2
1
2
1
2
1
3
1
3
4
5
5
7
1
Room  
Temp  
TH1  
TH2  
TH3  
TH4  
Coil  
E1  
3
6
7
1
2
3
Coil  
E2  
LL  
L
H
HH HT  
PNL  
Coil  
E3  
FMI  
DP  
1X  
1
2
2X  
RC1  
F2(5A)  
3X  
RY2  
1
2
OC  
3
9
3
DC12V  
5P-  
U2  
5P-  
U1  
3
To Outdoor Unit  
Symbols  
Description  
Symbols  
Description  
FMI  
Indoor Fan Motor  
CR  
Indoor Controller  
49FI  
RC1  
F1, 2  
DP  
Indoor Motor Thermal Protector  
Running Capacitor  
Fuse  
(RCU)  
Remote Control Unit  
(Optional Parts)  
(TH)  
Room Thermistor  
Terminal Plate  
Connector  
Drain Pump  
FS  
Float Switch  
TR1  
1X~3X  
RY2  
MOV  
TH1  
TH2  
TH3  
TH4  
Power Transformer  
Auxiliary Relay  
Terminal  
Auxiliary Relay  
Motor Operated Valve  
Room Thermistor  
Thermistor (Indoor Coil E1)  
Thermistor (Indoor Coil E2)  
Thermistor (Indoor Coil E3)  
S 854-2-5268-940-00-0 (UH1242)  
SM830082  
III - 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Electrical data  
Wall Mounted Type : KH2442  
G R N / Y E L  
2 P ( W H T )  
C o n n e c t e r  
B L K  
W H T  
B L K  
W H T  
G R Y  
B L K  
Y E L  
R E D  
O R G  
B L K  
B L K  
B L K  
B L K  
B L K  
B L K  
B L K  
B L K  
R E D  
G R Y  
W H T  
V L T  
O R G  
Y E L  
O R G  
B L K  
3
P N K  
B R N  
G R N  
O R G  
O R G  
R E D  
R E D  
B R N  
B R N  
W H T  
W H T  
2 P ( B L U )  
C o n n e c t e r  
B L K  
W H T  
B L U  
P N K  
W H T  
R E D  
SM830082  
III - 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Electrical data  
Wall Mounted Type : KH2442  
• Schematic Diagram  
CR  
CN2  
1
1
3
1
2
3
4
5
6
RC  
WL  
2
TH  
RCU  
T10  
Terminal  
Plate (4P)  
1
2
3
4
F1(5A)  
T20  
-1  
-2  
1
1
RS1  
TR1  
1X  
1
2
3
4
5
6
1
2
3
4
1
2
3
4
VCC  
2X  
3X  
RY1  
T6  
MOV  
5
5
1
3
RS2  
FS  
LM  
FM  
1
3
1
2
1
2
1
2
1
3
1
3
4
5
5
7
1
1
Room  
Temp  
3
TH1  
TH2  
TH3  
TH4  
Coil  
E1  
3
6
1
2
3
Coil  
E2  
LL  
L
H
HH  
PNL  
Coil  
E3  
FMI  
LM  
1X  
2X  
2
3
RC1  
F2(5A)  
3X  
RY1  
1
2
OC  
3
9
DC12V  
4P-  
U2  
4P-  
U1  
3
To Outdoor Unit  
Symbols  
Description  
Symbols  
Description  
FMI  
Indoor Fan Motor  
CR  
Indoor Controller  
49FI  
RC1  
F1, 2  
LM  
Indoor Motor Thermal Protector  
Running Capacitor  
Fuse  
(RCU)  
Remote Control Unit  
(Optional Parts)  
(TH)  
Room Thermistor  
Terminal Plate  
Connector  
Auto Louver Motor  
Power Transformer  
Auxiliary Relay  
TR1  
1X~3X  
RY1  
MOV  
TH1  
TH2  
TH3  
TH4  
Terminal  
Auxiliary Relay  
Motor Operated Valve  
Room Thermistor  
Thermistor (Indoor Coil E1)  
Thermistor (Indoor Coil E2)  
Thermistor (Indoor Coil E3)  
S 854-2-5268-935-00-0 (KH2442)  
SM830082  
III - 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Electrical data  
Wall Mounted Type : KH3642  
G R N / Y E L  
B L K  
W H T  
5 P ( W H T )  
C o n n e c t e r  
G R Y  
B L K  
Y E L  
R E D  
O R G  
G R Y  
B L K  
Y E L  
R E D  
O R G  
B L K  
B L K  
B L K  
B L K  
B L K  
B L K  
B L K  
B L K  
8 P ( W H T )  
C o n n e c t e r  
R E D  
G R Y  
W H T  
V L T  
G R Y  
W H T  
V L T  
O R G  
O R G  
Y E L  
Y E L  
B R N  
P N K  
O R G  
B L K  
3
P N K  
B R N  
G R N  
O R G  
O R G  
R E D  
R E D  
B R N  
B R N  
W H T  
W H T  
2 P ( B L U )  
C o n n e c t e r  
B L K  
W H T  
B L U  
P N K  
W H T  
R E D  
SM830082  
III - 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Electrical data  
Wall Mounted Type : KH3642  
• Schematic Diagram  
CR  
CN2  
1
1
3
1
2
3
4
5
6
RC  
WL  
2
TH  
RCU  
T10  
Terminal  
Plate (4P)  
1
2
3
4
F1(5A)  
T20  
-1  
-2  
1
1
RS1  
TR1  
1X  
1
2
3
4
5
6
1
2
3
4
1
2
3
4
VCC  
2X  
3X  
RY1  
T6  
MOV  
5
5
1
3
RS2  
FS  
LM  
FM  
1
3
1
2
1
2
1
2
1
3
1
3
4
5
5
7
1
Room  
Temp  
3
TH1  
TH2  
TH3  
TH4  
Coil  
E1  
3
6
1
2
3
Coil  
E2  
LL  
L
H
HH  
PNL  
Coil  
E3  
FMI  
LM  
1X  
1
2
7
9
2X  
RC1  
F2(5A)  
3X  
RY1  
1
2
OC  
3
3
DC12V  
4P-  
U2  
4P-  
U1  
3
To Outdoor Unit  
Symbols  
Description  
Symbols  
Description  
FMI  
Indoor Fan Motor  
CR  
Indoor Controller  
49FI  
RC1  
F1, 2  
LM  
Indoor Motor Thermal Protector  
Running Capacitor  
Fuse  
(RCU)  
Remote Control Unit  
(Optional Parts)  
(TH)  
Room Thermistor  
Terminal Plate  
Connector  
Auto Louver Motor  
Power Transformer  
Auxiliary Relay  
TR1  
1X~3X  
RY1  
MOV  
TH1  
TH2  
TH3  
TH4  
Terminal  
Auxiliary Relay  
Motor Operated Valve  
Room Thermistor  
Thermistor (Indoor Coil E1)  
Thermistor (Indoor Coil E2)  
Thermistor (Indoor Coil E3)  
S 854-2-5268-936-00-0 (KH3642)  
SM830082  
III - 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Electrical data  
3-2 Outdoor Units  
1 CH2442  
B R N  
B R N  
W H T  
W H T  
G R Y  
R E D  
W H T  
R E D  
R E D  
R E D  
B R N  
Y E L  
V L T  
Y E L  
V L T  
W H T  
B L K  
G R Y  
B R N  
W H T  
G R Y  
G R Y  
B R N  
B R N  
P N K  
P N K  
3
B R N  
Y E L  
W H T  
W H T  
W H T  
B L K  
W H T  
R E D  
B L K  
R E D  
SM830082  
III - 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Electrical data  
3-2 Outdoor Units  
1 CH2442  
• Schematic Diagram  
Terminal  
Plate (5P)  
-1  
CR  
63PH  
1
2P-1  
2P-2  
1
F1(5A)  
RY1 RY2  
-2  
1Y  
1Y  
RY3  
1
2
1
3
CN004  
AC 230V  
RS  
RY5  
L
63PH  
-G  
RY4  
TR  
H
3
M
20S 52C  
-L1  
-L2  
3
7
5
3
3
2
1
VCC  
AC 14V  
TH6  
TH7  
TH8  
49  
FO  
1
2
Outdoor  
Coil C1  
CT  
RY1  
20S  
52C  
FM1  
FM2  
52C  
Outdoor  
Coil C2  
1
2
3
4
RY2  
RY3  
RY4  
RY5  
1
5
6
7
H
M
L
1
2
Discharge  
gas  
49FO  
20S  
CH  
2
1Y  
52C  
FMO  
52C  
PTC  
RC1  
1
2
1
3
9
RC2  
CT1  
49  
C
DC12V  
N1  
R
C
S
1
1
1
CM  
3
F2(5A)  
Symbols  
Description  
Symbols  
Description  
CM  
Compressor Motor  
Outdoor Fan Motor  
CR  
RY1~RY5  
Outdoor Controller  
Auxiliary Relay  
Auxiliary Relay  
Terminal Plate  
Terminal  
3
FMO  
52C  
49FO  
63PH  
CT  
Compressor Motor Magnetic Contactor 1Y  
Outdoor Fan Motor Thermal Protector  
High Pressure Switch  
Current Transmitter  
Connector  
RC1,2  
TR  
Running Capacitor  
Power Transformer  
CH  
Crank Case Heater  
20S  
Four Way Valve  
F1,2  
TH6  
TH7  
TH8  
PTC  
Fuse  
Thermistor (Outdoor Coil C1)  
Thermistor (Outdoor Coil C2)  
Thermistor (Discharge Gas)  
PTC Thermistor  
S 854-2-5268-945-00-0 (CH2442-S)  
SM830082  
III - 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Electrical data  
3-2 Outdoor Units  
2 CH3642  
B R N  
B R N  
W H T  
W H T  
G R Y  
R E D  
W H T  
R E D  
R E D  
R E D  
Y E L  
V L T  
W H T  
B R N  
Y E L  
V L T  
Y E L  
V L T  
W H T  
G R Y  
W H T  
G R Y  
G R Y  
B R N  
B R N  
P N K  
B R N  
P N K  
3
Y E L  
V L T  
W H T  
Y E L  
V L T  
W H T  
G R Y  
G R Y  
B R N  
G R Y  
G R Y  
B R N  
B R N  
P N K  
P N K  
B R N  
Y E L  
W H T  
W H T  
W H T  
B L K  
W H T  
R E D  
B L K  
R E D  
SM830082  
III - 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Electrical data  
3-2 Outdoor Units  
2 CH3642  
• Schematic Diagram  
Terminal  
Plate (5P)  
-1  
CR  
63PH  
1
2P-1  
2P-2  
1
F1(5A)  
RY1 RY2  
-2  
1Y  
1Y  
RY3  
1
2
1
3
CN004  
AC 230V  
RS  
RY5  
L
63PH  
-G  
RY4  
TR  
H
3
M
20S 52C  
-L1  
-L2  
3
7
5
3
3
2
1
VCC  
AC 14V  
3
TH6  
TH7  
TH8  
49  
FO  
1
2
Outdoor  
Coil C1  
49FO1  
CT  
RY1  
20S  
52C  
FM1  
FM2  
52C  
Outdoor  
Coil C2  
1
2
4
3
RY2  
RY3  
RY4  
RY5  
1
5
6
7
5
6
7
H
M
L
H
M
L
1
2
Discharge  
gas  
20S  
CH  
2
1Y  
52C  
FMO1 FMO2  
49FO2  
52C  
PTC  
RC1  
4
1
2
1
2
1
3
9
RC2  
RC3  
CT1  
49  
C
DC12V  
N1  
R
C
S
1
1
1
CM  
3
F2(5A)  
Symbols  
Description  
Symbols  
Description  
CM  
Compressor Motor  
Outdoor Fan Motor  
CR  
RY1~RY5  
Outdoor Controller  
Auxiliary Relay  
Auxiliary Relay  
Terminal Plate  
Terminal  
3
FMO1,2  
52C  
Compressor Motor Magnetic Contactor 1Y  
Outdoor Fan Motor Thermal Protector  
High Pressure Switch  
Current Transmitter  
49FO1,2  
63PH  
CT  
Connector  
RC1,2,3  
TR  
Running Capacitor  
Power Transformer  
CH  
Crank Case Heater  
20S  
Four Way Valve  
F1,2  
Fuse  
TH6  
Thermistor (Outdoor Coil C1)  
Thermistor (Outdoor Coil C2)  
Thermistor (Discharge Gas)  
PTC Thermistor  
TH7  
TH8  
PTC  
S 854-2-5268-946-00-0 (CH3462-S)  
SM830082  
III - 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Electrical data  
3-2 Outdoor Units  
3 CH4242  
B R N  
B R N  
W H T  
W H T  
G R Y  
R E D  
W H T  
R E D  
R E D  
R E D  
Y E L  
V L T  
W H T  
B R N  
Y E L  
V L T  
Y E L  
V L T  
W H T  
G R Y  
W H T  
G R Y  
G R Y  
B R N  
B R N  
P N K  
B R N  
P N K  
3
Y E L  
V L T  
W H T  
Y E L  
V L T  
W H T  
G R Y  
G R Y  
B R N  
G R Y  
G R Y  
B R N  
B R N  
P N K  
P N K  
B R N  
Y E L  
W H T  
W H T  
W H T  
B L K  
W H T  
R E D  
B L K  
R E D  
SM830082  
III - 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Electrical data  
3-2 Outdoor Units  
3 CH4242  
• Schematic Diagram  
Terminal  
Plate (5P)  
-1  
CR  
63PH  
1
2P-1  
2P-2  
1
F1(5A)  
RY1 RY2  
-2  
1Y  
1Y  
RY3  
1
2
1
3
CN004  
AC 230V  
RS  
RY5  
L
63PH  
-G  
RY4  
TR  
H
3
M
20S 52C  
-L1  
-L2  
3
7
5
3
3
2
1
VCC  
AC 14V  
3
TH6  
TH7  
TH8  
49  
FO  
1
2
Outdoor  
Coil C1  
49FO1  
CT  
RY1  
20S  
52C  
FM1  
FM2  
52C  
Outdoor  
Coil C2  
1
2
4
3
RY2  
RY3  
RY4  
RY5  
1
5
6
7
5
6
7
H
M
L
H
M
L
1
2
Discharge  
gas  
20S  
CH  
2
1Y  
52C  
FMO1 FMO2  
49FO2  
52C  
4
1
2
1
2
1
3
9
RC2  
RC3  
RC1  
CT1  
49  
C
DC12V  
N1  
R
C
S
1
1
1
CM  
3
F2(5A)  
Symbols  
Description  
Symbols  
Description  
CM  
Compressor Motor  
Outdoor Fan Motor  
CR  
RY1~RY5  
Outdoor Controller  
Auxiliary Relay  
Auxiliary Relay  
Terminal Plate  
Terminal  
3
FMO1,2  
52C  
Compressor Motor Magnetic Contactor 1Y  
Outdoor Fan Motor Thermal Protector  
High Pressure Switch  
49FO1,2  
63PH  
CT  
Current Transmitter  
Connector  
RC1,2,3  
TR  
Running Capacitor  
Power Transformer  
CH  
Crank Case Heater  
20S  
Four Way Valve  
F1,2  
Fuse  
TH6  
Thermistor (Outdoor Coil C1)  
Thermistor (Outdoor Coil C2)  
Thermistor (Discharge Gas)  
TH7  
TH8  
S 854-2-5268-948-00-0 (CH4242-S)  
SM830082  
III - 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. SERVICE PROCEDURES  
4-1 Troubleshooting ...................................................................................... IV - 2  
(1) Check before and after Troubleshooting ......................................... IV - 3  
(2) General Troubleshooting Flow Chart: Diagnosis and Remedy ....... IV - 4  
(3) Meanings of alarm messages.......................................................... IV - 6  
(4) LED Indication on the Outdoor Unit’s P.C.B. Ass’y ......................... IV - 8  
(5) Symptoms and parts to inspect ....................................................... IV - 9  
(6) Procedures When a Specific Component Does Not Work .............. IV - 19  
(7) Service Functions of Remote Controller .......................................... IV - 21  
n  
4-2 Checking the Electrical Components ...................................................... IV - 30  
(1) Measurement of Insulation Resistance ........................................... IV - 30  
(2) Checking the Protective Devices..................................................... IV - 31  
(3) Checking the Electrical Parts........................................................... IV - 32  
(4) Thermistor Characteristic Curve ...................................................... IV - 35  
(5) PCB Setting ..................................................................................... IV - 36  
(6) R.C Address Setting Method ........................................................... IV - 37  
(7) Automatic Address Setting Method ................................................. IV - 38  
(8) Displaying Indoor / Outdoor Unit Combination Numbers................. IV - 38  
(9) Items to Check Prior to Test Run .................................................... IV - 39  
(10) Test Run .......................................................................................... IV - 40  
(11) PCBs and Their Location................................................................. IV - 42  
(12) Checking procedure for each PC Board.......................................... IV - 44  
(13) TMX60 Pins ..................................................................................... IV - 45  
4
SM830082  
IV - 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
4-1 Troubleshooting  
This section explains:  
What the LED codes mean  
What the remote control unit display screen messages mean  
How to use the flow charts to find and solve problems  
How to use the self-diagnostic tests to find parts that aren’t working right  
S
This unit is made to be trouble free, and not need much service. However, with time, moving  
parts wear out, electronic components break down, and sometimes misuse damages the unit.  
The purpose of this section is to help you when the unit is not working properly. Sometimes  
your experience will tell you right away where to look for a problem, and when you find it you  
will know how to fix it at once.  
Often, however, all you have is a symptom like “poor cooling” or “outside fan doesn’t come  
on.” Now you must find out the cause of the problem, and then how to fix it. This section  
provides several ways to help you go from the symptom to the cause and then the solution.  
The first chart, General Troubleshooting Flow Chart is divided into two sections: Poor  
heating and Poor Cooling. Under each heading you will find the main things that can go  
wrong and cause either of these problems. Sometimes you can start with this chart and find  
the problem right away, but often you will come here for more suggestions after you have  
looked at the error code on the remote control unit display. This chart gives you the "big  
picture" of problems and solutions.  
The other main tool we explain here is the use of the Alarm Messages. When a certain part  
fails or a safety device has shut the unit down, any alpha-numeric codes appears on the  
display to guide you to the problem.  
By understanding the code you can often go right to the problem area and then, with this  
manual and your knowledge of air conditioning, find the solution.  
4
SM830082  
IV - 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
(1) Check before and after Troubleshooting  
Many problems may happen because of wiring or power supply problems, so you should  
check these areas first. Problems here can cause false results in some of the other tests, and  
so should be corrected first.  
1. Check power supply wiring  
Check the power supply wires are correctly connected between terminal  
No. 1 & 2 on the 5P terminal plates in the indoor unit and the outdoor unit.  
2. Check inter-unit wiring  
n  
Check that inter-unit control wiring (DC low voltage) is correctly connected between the  
indoor unit and outdoor unit.  
Power Supply: 60 Hz, single-phase, 230/208 V  
Indoor Unit  
Outdoor Unit  
B
R.C. Address on the PCB: 0 (S2, BLK)  
(0: Factory shipped state)  
1
2
1
2
Inter-unit  
0
power wiring  
Single phase  
230/208V  
4
G
G
Ground  
Inter-unit  
control wiring  
(Low voltage)  
U1  
U2  
U1  
L1  
U2  
L1  
Power supply  
Single phase  
230/208V  
C
L2  
L2  
G
1
2
1
2
1
2
Ground  
D
A
Remote controller  
(Option)  
*Remote controller wirings are wire joint connection.  
2085_M_I  
Fig. IV-1  
3. Check power supply  
Check that voltage is within the specified range (±10% of the rating).  
Check that power is being supplied.  
If the following troubleshooting must be done with power being supplied, be  
careful not to touch any uninsulated live part that can cause ELECTRIC  
SHOCK.  
4. Check the lead wires and connectors in indoor and outdoor units.  
Check that the sheath of lead wires is not damaged.  
Check that the lead wires are firmly connected at the terminal plate.  
Check that the wiring is correct.  
SM830082  
IV - 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
(2) General Troubleshooting Flow Chart: Diagnosis and Remedy  
When you have found a major problem, such as refrigerant not flowing in the system or  
reduced air circulation, come to this section and find the box listing the problem. Connected  
to the box are the main causes of the problem and their remedies. To find out which  
malfunction is happening in your case, check the remote controller for an Alarm Message,  
and follow the steps in section 3).  
(A) Cooling  
a. Cooling  
S
Poor cooling  
Is setting temp.  
Change the setting temp.  
suitable ?  
Is cooling load  
too heavy ?  
Review cooling load  
estimate.  
4
Refrigerant flow  
failure  
4-way valve is  
defective.  
Replace the 4-way valve.  
Charge refrigerant gas.  
Refrigerant  
shortage  
Electronic refrigerant  
Replace the valve.  
control valve is defective.  
Compressor is defective.  
Replace the compressor.  
Open the valves fully.  
Service valves are not  
fully open.  
Not enough air  
circulation  
Air filter  
Clean the filter.  
is clogged.  
Is fan speed  
set to LOW ?  
Set the fan speed to  
either MEDIUM or HIGH.  
Refrigerant tubes between  
indoor and outdoor units  
are not insulated.  
Insulate wide and narrow  
tubes separately.  
0458_M_I  
SM830082  
IV - 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
(B) Heating  
b. Heating  
Poor heating  
Is setting temp.  
suitable ?  
Change the setting temp.  
Is heating load  
too large ?  
Review heating load  
estimate.  
n  
Refrigerant flow  
failure  
4-way valve is  
defective.  
Replace the valve.  
Refrigerant  
shortage  
Charge with  
refrigerant.  
Electronic refrigerant  
Replace the valve.  
4
control valve is defective.  
Compressor is defective.  
Replace the compressor.  
Service valves are not  
fully open.  
Open the valves fully.  
Clean the filter.  
Not enough  
Air filter  
air circulation  
is clogged.  
Is fan speed  
set to LOW ?  
Set the fan speed to  
either MEDIUM or HIGH.  
Refrigerant tubes between  
indoor and outdoor units  
are not insulated.  
Insulate wide and narrow  
tubes separately.  
Cold air is  
4-way valve is  
defective.  
Replace the valve.  
discharged.  
Cold draft prevention  
is not working.  
“ STANDBY ” is  
displayed.  
Replace indoor  
P.C.B. Ass'y.  
Indoor coil sensor E2 is  
defective.  
Replace the sensor.  
0459_M_I  
SM830082  
IV - 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
(3) Meanings of alarm messages  
Alarm  
message  
Possible Cause of Malfunction  
Remote controller is detecting  
error signal from indoor unit.  
E1  
E2  
• Serial  
commu-  
nication  
errors  
• Indoor unit is detecting error signal from the remote controller.  
(No serial communications signal)  
E3  
• Mis-setting  
Indoor unit is detecting error  
signal from outdoor unit.  
E4  
E5  
Outdoor unit is detecting error  
signal from indoor unit.  
E6  
S
Indoor unit is not working  
correctly.  
Outdoor unit is transmitting error  
signal.  
E7  
Improper setting of indoor unit or  
remote controller.  
E8  
E9  
E12  
E14  
E15  
When using group control, main indoor unit address setting is duplicated.  
(For single heat pump type.)  
4
Error in Auto. address setting.  
(No. or capacity of judged indoor unit is small.)  
Error in Auto. address setting.  
E16  
E18  
(No. or capacity of judged indoor unit is large.)  
Indoor unit is detecting error signal from another indoor unit.  
Activation of  
protective  
device  
Protective device in indoor unit • Thermal protector in indoor fan motor is activated.  
is activated.  
P1  
P2  
Protective device in outdoor  
unit is activated.  
• Thermal protector in outdoor fan motor is activated.  
• Comp. thermal protector is activated.  
Incorrect discharge gas temp. of comp.  
High-pressure switch is activated.  
P3  
P4  
Incorrect power supply voltage . Negative phase, defective  
phase or voltage drop.  
P5  
Incorrect discharge gas temp. of comp.  
P17  
P9  
Protective device in indoor unit Improper wiring connections of ceiling panel.  
is activated.  
Float switch is activated.  
P10  
NOTE  
RCU : Remote Control Unit (remote controller)  
R.C. : Refrigerant Circuit  
comp. : Compressor  
temp. : Temperature  
PCB : Printed Circuit Board  
SM830082  
IV - 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
Alarm  
message  
Possible Cause of Malfunction  
Thermistor  
failure  
F1  
F2  
F3  
Indoor thermistor is either open Indoor coil temp. (E1 = TH1) cannot be detected.  
or damaged.  
Indoor coil temp. (E2 = TH2) cannot be detected.  
Indoor coil temp. (E3 = TH3) cannot be detected.  
Indoor room (air-intake) temp. can not be detected.  
Discharge gas temp. (comp. = TH0A) cannot be detected.  
Outdoor coil gas temp. (C2 = TH0C) cannot be detected.  
Outdoor coil liquid temp. (C1 = TH0D) cannot be detected.  
F10  
F4  
Outdoor thermistor is either  
open or damaged.  
F25  
F7  
EEPROM (ICB of PCB) failure  
F29  
H1  
n  
Fault with  
comp. and its  
circuit  
Comp. motor is overloaded.  
Protective device for comp. is  
activated.  
Comp. motor is locked.  
H2  
Current of comp. cannot be detected when it is turned on.  
Current of comp. is detected when it is not operated.  
Comp. contactor (Mg SW) is chattering.  
H3  
F27  
H18  
Alarm  
message  
Possible cause of Malfunction  
Model setting of indoor unit is not matching the outdoor unit.  
L2  
4
When using group control, main indoor unit address setting is duplicated.  
(Judging by indoor unit.)  
L3  
Outdoor unit address (R.C. No.) is duplicated.  
L4  
L5  
L6  
Priority setting of indoor unit is duplicated.  
Improper wiring between indoor units.  
L7  
(There is group connection wiring in case of individual control.)  
L9  
Capacity code of indoor unit is not set.  
Improper wiring of group control wiring.  
L11  
Alarm  
message  
Possible Cause of Malfunction (The following messages are displayed only for the system controller.)  
• Indoor or outdoor unit is not working correctly.  
• Control lines between indoor unit, outdoor unit, and system  
controller are not wired correctly.  
• Serial  
commu-  
nication  
errors  
System controller is transmitting  
incorrect signal.  
C05  
C06  
P30  
System controller is detecting  
incorrect signal.  
• Same as for C05, above.  
• Connector CN1 is not connected correctly.  
• Mis-setting  
Protective device of the sub-  
indoor unit is activated in group connect wired remote controller with the indoor unit temporarily  
contorl.  
When using wireless remote controller or system controller,  
Activation of  
protective  
device  
to check the alarm message in detail.  
NOTE  
R.C. : Refrigerant Circuit  
comp. : Compressor  
temp. : Temperature  
PCB : Printed Circuit Board  
SM830082  
IV - 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
(4) LED Indication on the Outdoor Unit’s P.C.B. Ass’y  
If something goes wrong with the outdoor unit, LED lamps on the outdoor P.C.B. Ass’y light  
up to show the cause of the trouble, in addition to the Alarm message on the remote  
controller.  
LED 2 on LED 1 on Remote  
Possible cause of trouble  
P.C. board P.C. board controller  
Normal  
No message  
E06, E07, L04  
Outdoor unit serial communication signal is abnormal.  
Outdoor unit address is duplicated.  
Other outdoor units are performing auto address and  
detecting refrigerant shortage.  
S
*
No message  
P02  
FMo • CM thermal protection is in operation.  
Power supply voltage is abnormal.  
High voltage SW activates  
P04, P05  
Negative phase protector activates.  
Sensor is abnormal. (Open or short)  
Abnormal compressor current value is detected.  
Auto address failure  
*
F04~F09  
H01, H02  
4
*
*
*
E15, E16  
Flash at the same time  
*
*
“SETTING”  
flashes.  
Auto address is in operation.  
Flash alternately  
NOTE : LED lamps OFF : LED lamps ON (lights up) *: LED lamps ON (blink)  
Outdoor control PCB  
LED2 (D012)  
LED1 (D011)  
Fig. IV-2  
2177_C_I  
CAUTION  
* REFRIGERANT SHORTAGE  
Note particularly that a shortage of refrigerant is only shown by the outdoor P.C.B. Ass’y  
LEDs and the Alarm Message does not appear on the Indoor Remote Controller . The  
compressor keeps running even when the refrigerant is less, so when you find the LED  
indication on the outdoor P.C.B. Ass’y, stop the air conditioner immediately to avoid the  
compressor damage.  
SM830082  
IV - 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
(5) Symptoms and parts to inspect  
1) Symptom: LCD on the remote controller does not display and remote controller does not  
operate.  
Start  
Is the LED (D80) on  
the indoor unit PCB lit?  
Repair the  
remote  
Yes  
controller  
wiring.  
No  
n  
No  
Yes  
Is there 230-208 V AC  
between R and S of  
the indoor PCB?  
Miswiring of  
power supply  
wires and  
Is there 230-208 V AC  
between U1 and U2  
of the terminal plate?  
indoor/outdoor  
control lines  
No  
Yes  
4
Check and repair the  
power breaker etc.  
Correct the  
wiring. Remove the  
socket connected to  
the OC plug on the  
PCB and connect to  
the EMG plug instead.  
No  
No  
Are the connections  
for the 4P connector  
for the indoor unit’s  
PCB power trans-  
former good?  
Correct the  
connections  
Has the indoor  
unit PCB fuse blown?  
Yes  
Yes  
No  
No  
Replace the  
Is the primary  
side of the indoor  
power transformer  
shorted?  
Is there 15 V AC  
Replace the  
indoor unit power  
transformer.  
Is the 230-208 V AC  
circuit shorted?  
No  
between 1 and 2  
of the 4P connector  
for the indoor unit’s  
power transformer?  
indoor unit PCB.  
Yes  
Yes  
Yes  
Replace the  
indoor unit PCB.  
Replace the indoor unit’s  
power transformer.  
Replace or repair.  
2095_THS_I  
SM830082  
IV - 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
2) Symptom: LCD on the remote controller displays “CHECK E01”. (Unusual  
communication between remote controller and indoor unit.)  
Start  
Remote controller judges itself  
with self-diagnostic functions  
NG  
Replace the remote controller.  
OK  
S
Is there an open or a contact  
defect in the No. 1 line of the  
remote controller?  
Yes  
Correct the wiring.  
No  
Is there 230 -208 V AC between  
U1 and U2 of terminal plate?  
Mis-wiring between the power  
supply line and indoor/ outdoor  
unit operation lines.  
Correct the wiring, and pull out the  
socket connected to the OC plug  
to replace with the EMG plug.  
Yes  
Yes  
Yes  
No  
4
Is the indoor unit PCB’s inspection  
pin shorted?  
Open the inspection pin.  
No  
Replace the indoor unit PCB  
.
2096_THS_I  
3) Symptom: LCD on the remote controller displays “CHECK E02”. (Unusual  
communication between remote controller and indoor unit)  
Start  
NG  
Remote controller judges itself with  
self-diagnostic functions.  
Replace the remote controller.  
OK  
Replace the indoor unit PCB.  
2097_M_I  
SM830082  
IV - 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
4) Symptom: LCD on the remote controller is displaying “CHECK E04”. (Unusual  
communication between the indoor and outdoor units.)  
Start  
No  
No  
Cut the breaker and remove the  
indoor/outdoor unit control lines  
connected to U1 and U2 of the  
indoor unit 8P terminal plate.  
After shorting the test pin (CN2)  
on the indoor unit PCB, switch the  
breaker on. Does the LED  
Is the contact good at the 2P  
connector for indoor serial  
communications on the outdoor  
unit PCB?  
Correct the connections.  
Yes  
n  
(red) on the PCB light up?  
Replace the indoor unit PCB.  
Yes  
No  
No  
Is the contact good at the 2P  
connector for indoor serial  
communications on the outdoor  
unit PCB?  
Correct the connections.  
Cut the breaker, remove the  
indoor/outdoor unit control  
lines connected to U1 and U2 of  
the outdoor unit 8P terminal plate.  
After shorting the test pin (CN11) on  
the outdoor unit PCB, switch the  
breaker on. Do the LEDs (red, × 2)  
on the PCB flash?  
4
Yes  
Replace the indoor unit PCB.  
Indoor/outdoor unit  
control lines are cut off  
Correct the wiring.  
0335_M_I  
5) Symptom: LCD on the remote controller is displaying “CHECK E05”. (Unusual  
communication between the indoor and outdoor units)  
Start  
Indoor unit PCB transmission/  
reception circuit defect  
Replace the indoor unit PCB.  
0336_M_I  
SM830082  
IV - 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
6) Symptom: LCD on the remote controller is displaying “CHECK E06”. (Unusual  
communication between the indoor and outdoor units)  
Start  
Yes  
Correct the setting.  
Correct wiring.  
Is the setting for the indoor address  
on the indoor unit PCB inappropriate?  
No  
Yes  
Is there a cut line or contact  
defect between an indoor and  
outdoor unit’s control line?  
S
No  
0337_M_I  
Influenced by external noise  
7) Symptom: LCD on the remote controller is displaying “CHECK E08”. (Duplicate indoor  
unit address setting)  
4
Start  
Yes  
Is the setting for the non-volatile  
memory IC on the indoor unit PCB  
inappropriate? If the setting is  
appropriate, “F29” is displayed.  
(Are there two units with the same  
address?)  
Correct the setting.  
No  
Influenced by external noise  
0338_M_I  
8) Symptom: LCD on the remote controller is displaying “CHECK E09”. (Duplicate setting  
of RCU address switch of remote controllers)  
Start  
*
Yes  
Are there two remote controllers  
(master-slave) installed with both  
remote controllers set as masters?  
Correct the setting.  
No  
Replace the remote controller.  
0339_M_I  
SM830082  
IV - 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
9) Symptom: LCD on the remote controller displays “CHECK P01”. (Indoor fan protection  
thermostat operation warning)  
Start  
Yes  
No  
Correct the connection  
Is there 230-208 V AC between T20-1  
and T20-3 on the indoor unit PCB?  
Is the indoor fan wire winding  
protection thermostat (49FI) off?  
Yes  
Yes  
No  
n  
Replace the indoor unit PCB.  
Replace the indoor fan.  
2098_THS_I  
4
SM830082  
IV - 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
10) Symptom: LCD on the remote controller displays “CHECK P02”. (Compressor / outdoor  
fan protection thermostat operation warning / power supply voltage  
abnormality)  
Start  
No  
Is the power supply to the outdoor  
unit normal?  
Check the power breaker etc.  
and repair.  
(Voltage / defective phase?)  
S
Yes  
Yes  
Yes  
Yes  
Is the fuse on the outdoor unit  
PCB blown (F1 and F2)?  
Replace the fuse.  
No  
Is the high pressure switch  
(63 PH) off?  
Replace the outdoor unit PCB.  
Replace the outdoor unit PCB.  
4
No  
Is there 230-208 V AC between  
CN19-9 and CN19-7 on the  
outdoor unit PCB?  
No  
No  
Is the outdoor fan wire winding  
protection thermostat (49FO) off?  
Yes  
• No refrigerant  
• High load  
• 4-way valve defect  
• Clogged refrigerant circuit  
• Electronic refrigerant control valve  
defect (indoor unit)  
Replace the outdoor fan.  
Yes  
Is there connector contact defect?  
Correct the connection  
No  
Replace the outdoor unit PCB.  
2099_THS_I  
SM830082  
IV - 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
11) Symptoms: LCD on the remote controller displays “CHECK P03”.  
(Alarm for unusual discharge temp. of compressor)  
Start  
Unusual discharge gas temperature  
• Refrigerant shortage  
n  
• Clogged refrigerant circuit  
• Electronic refrigerant control  
valve defect (indoor unit)  
0343_M_I  
12) Symptom: LCD on the remote controller displays “CHECK P04”. (High-pressure switch  
activation warning)  
4
Start  
No  
Yes  
The system does not operate again.  
Yes  
Are there connection defects in  
the wiring?  
Repair the wiring.  
No  
High-pressure switch defect  
High-pressure switch activation  
(Both cooling and heating)  
• Electronic refrigerant control valve  
defect  
Refrigerant over-charged  
(Cooling)  
• Outdoor unit, heat exchanger dirty,  
clogged  
• Outdoor unit air short  
• Outdoor fan stopped  
(Heating)  
• Outdoor unit air short  
• Indoor unit, heat exchanger dirty,  
clogged  
• Large pipe side service valve  
closed  
• Indoor fan stop  
• Air filter clogged  
0344_M_I  
SM830082  
IV - 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
13) Symptom: LCD on the remote controller displays “CHECK P05”. (Negative phase  
detection operation warning)  
Start  
No  
Is the power supply to the outdoor  
unit normal?  
Check the power breaker etc.  
and repair  
(Voltage defective phase?)  
Yes  
S
Yes  
Does the outdoor unit operate when  
two of the three phases are changed?  
(Actuation of negative phase protector)  
No problem  
No  
Yes  
Yes  
Is the fuse (F1, F2) on the indoor  
unit PCB blown?  
Replace the fuse.  
No  
4
Is there a contact defect in the  
3P connector?  
Correct the connection  
No  
Replace the outdoor PCB  
0345_M_I  
14) Symptom: LCD on the remote controller displays “CHECK E15”.  
Start  
Yes  
Yes  
When the group of the units are  
installed, is there any mis-cross  
between interunit control wiring and  
refrigerant tubing?  
Repair the wiring.  
No  
Are the total capacities of indoor units  
to that of outdoor units less than 93%?  
Select an indoor unit which matches  
with the outdoor capacity.  
No  
Yes  
Are there no contact failure between  
outdoor and indoor units?  
Check the contact.  
No  
Perform the same as “CHECK E04”.  
0646_M_S  
SM830082  
IV - 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
15) Symptom: LCD on the remote controller displays “CHECK E16”.  
Start  
Yes  
Yes  
When the group of the units are  
installed, is there any mis-cross  
between inter unit control wiring and  
refrigerant tubing?  
Repair the wiring.  
No  
n  
Are the total capacities of indoor units  
to that of outdoor units more than 107%?  
Select indoor units which match with  
the outdoor capacity.  
No  
Confirm less than 5 indoor units are  
connected.  
0647_M_S  
4
16) Symptom: LCD on the remote controller displays “CHECK L13”.  
Start  
Yes  
When the group of the units are  
installed, is there any mis-cross  
between inter unit control wiring and  
refrigerant tubing?  
Repair the wiring.  
No  
Check the capacity of the indoor unit  
by remote controller.  
0648_M_S  
See Test Run Manual.  
17) “Check P9” is displayed on the remote control unit.  
Start  
Yes  
Is PNL connector socket  
being attached to panel  
Connect firmly.  
connected firmly with PNL plug?  
Yes  
Replace P.C.B. Ass’y in the  
indoor unit.  
2100_M_S  
SM830082  
IV - 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
18) Symptom: LCD on the remote controller displays “CHECK H01, H02, H03”.  
(compressor current detection)  
* Please check the related part described in the following chart after confirming the code  
setting (S4) of the outdoor unit’s capacity on the PCB in the outdoor unit.  
Start  
“CHECK H01” display  
Compressor overload  
“CHECK H03” display  
“CHECK H02” display  
S
Compressor current detection  
circuit defect  
Compressor lock detection  
detection  
• Insufficient voltage  
• Comp. motor magnetic contactor  
defect  
• L3 phase wire disconnected  
• Comp. motor magnetic contactor  
defect  
Compressor lock  
• Refrigerant over-charged  
• Outdoor unit PCB defect  
4
0346_M_I  
19) Check the indoor unit (When the alarm of communication failure is not activated)  
If the electronic control valve failure occurred in Flexible Combination system  
(simultaneous operation system), one indoor unit would not be operated normally, then  
the other units won’t be operated either. Due to this, try to detect the troubled unit and  
correct it.  
Operate the unit in  
cooling mode.  
(30 minutes after its operation)  
• Cooled air comes out.  
Yes  
• Is the temperature of each indoor coil sensor almost  
Normal  
the same? (Refer to the sensor temperature  
display function of the remote controller.)  
No  
• Does each indoor coil sensor detect the temperature  
correctly? (Is there any leakage from the pipe of the  
temperature detection section?)  
Yes  
Failure in the electronic  
control valve activation.  
No  
Replace the sensor.  
0460_M_I  
SM830082  
IV - 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
(6) Procedures When a Specific Component Does Not Work  
1) Indoor fan does not operate.  
No  
Is fan motor capacitor  
normal ?  
Replace the capacitor.  
Yes  
Is there voltage output  
of P.C.B. Ass'y for fan  
motor ?  
No  
Replace the P.C.B. Ass'y  
in the indoor unit.  
n  
Yes  
• Check resistance of  
fan motor winding.  
Out  
Replace the fan motor.  
4
0650_M_S  
2) Flaps in indoor unit’s air outlet does not operate, when you press SWEEP button.  
No  
Check the louver motor resistance.  
Replace the motor.  
Is auto louver motor normal?  
Is PNL connector socket  
attached to panel  
connected firmly with PNL plug ?  
No  
Connect firmly.  
Yes  
Replace P.C.B. Ass'y in the  
indoor unit.  
2101_M_S  
3) Flap does not operate, when you press  
button. (When you press SWEEP button,  
flap operates.)  
No  
Does limit switch actuate?  
Replace the switch.  
Yes  
Is PNL connector socket  
No  
attached to panel  
Connect firmly.  
connected firmly with PNL plug ?  
Yes  
Replace P.C.B. Ass'y in the  
indoor unit.  
2102_M_S  
SM830082  
IV - 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
4) Compressor motor does not operate.  
No  
Does compressor motor magnetic  
contactor (52C) actuate ?  
Replace the compressor  
motor magnetic contactor.  
Yes  
Check resistance of compressor  
motor winding.  
S
NG  
Replace the compressor.  
0461_M_I  
5) Outdoor fan does not operate.  
4
Are auxiliary relays (1Y)  
No  
Replace the relays.  
normal ?  
Yes  
No  
Replace the capacitor.  
Is fan motor capacitor normal ?  
Yes  
No  
Is there voltage output of  
Replace P.C.B. Ass’y  
in the outdoor unit.  
P.C.B. Ass’y for fan motor ?  
Yes  
Check resistance of fan motor  
winding.  
NG  
Replace the fan motor.  
1148_THS_I  
SM830082  
IV - 20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
(7) Service Functions of Optional Wired Remote Controller  
From the remote controller you can control both the operation and settings of the unit as well  
as perform several useful service checks. This section explains how to use the remote  
controller on the following items from (A) to (I).  
(A) Use the test run procedure.  
(B) Check the sensor temperature readings.  
(C) Accessing the service problem history.  
(D) Check the remote controller itself for correct operation.  
(E) Excute the auto. address operation.  
(F) Confirm and change the indoor unit address.  
(G) Change the shift temperature in heating mode  
(H) Set the indoor unit address.  
( I ) Change the period of the filter timer  
n  
(A) Use the test run procedure  
a After holding down the remote controller  
button for 4 seconds or more, press the  
button.  
• While the test is running, “TEST” shows on the LCD display.  
• In “TEST” mode, the temperature cannot be adjusted. Do not use this mode except  
during test run operation.  
b Use “TEST” mode in either heating or cooling operation mode.  
4
NOTE  
The outdoor unit will not start running for approximately 3 minutes after the power is  
turned on or the unit is turned off.  
c When the unit is not operating normally, a  
code will be displayed on the remote  
controller LCD. Refer to the Table of  
Self-Diagnostic Functions at “- - -”, and  
take the corrective measures indicated.  
d After completing the test run operation,  
press the  
button again and check to  
a
see that “TEST” is no longer displayed on  
the remote controller LCD.  
(The remote controller is equipped with a  
timer that terminates test run operation  
after 60 minutes in order to prevent con-  
tinuous test run operation.)  
a, d  
2076_M_I  
Fig. IV-3  
SM830082  
IV - 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
(B) Check the sensor temperature readings  
The air conditioner has thermo sensors which are used to control the unit.  
Each sensor has an address which is made up of the indoor unit address, and the  
sensor address. The indoor unit address is used only when several units are hooked  
up to one remote controller (group control). If there is only one unit, made up of one  
indoor and one outdoor unit, then only the sensor address should be put in, as shown  
in the procedure below.  
Follow this procedure to display the temperature of each sensor:  
a On the remote controller, press both  
and  
buttons at the same time for more than 4  
seconds. (Ref. Fig. IV-4)  
b The UNIT No., the address and temperature of the sensors instead of its usual informa-  
tion will flash on the display.  
S
Following example shows the UNIT No. (Indoor unit address) is fixed at 01– 01.  
In case of group control, select the UNIT NO. (Indoor unit address) which you want to  
check with  
Each time you press the  
button.  
,
( ) button you can select a different sensor, and the  
display shows the sensor address and temperature as shown Fig. IV-4.  
Sensor address  
4
Sensor temperature °F  
Unit No. (Indoor unit address)  
a
1929_M_I  
Fig. IV-4  
SM830082  
IV - 22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
Refer to the table below for the relationship between the sensor address and the location of the sensor.  
Relationship between the sensor address and the location of sensor  
Sensor Address  
Location of Sensor (Themistor)  
(CODE No.)  
Indoor Unit  
00  
01  
02  
03  
04  
05  
06  
07  
08  
09  
A/C controlled room Temp.  
Remote controller room Temp.  
Indoor air suction Temp.  
Indoor coil Temp. (E1)  
Indoor coil Temp. (E2)  
Indoor coil Temp. (E3)  
Indoor electronic expantion valve Temp.  
Outdoor Unit 0A  
Discharge gas Temp.  
0B  
0C  
0D  
0E  
0F  
10  
11  
12  
13  
14  
Outdoor coil liquid Temp. (C2)  
Outdoor coil liquid Temp. (C1)  
n  
NOTE  
In case there are no sensor equipped with the unit, “- - -” is shown on the display.  
C Resetting the remote controller display to previous mode.  
To reset the display, press  
button, then the remote controller will return to previous mode.  
(C) Accessing the service problem history  
The gist of past service problems can be recalled.  
4
a Press the  
and  
buttons simultaneously for 4 seconds or more to enter the service  
check mode. The term “CHECK SERVICE” will be illuminated and code No. 01 will be  
displayed at first. Then the most recent alarm message will be displayed, showing the  
number of the indoor unit that generated the alarm and the nature of the alarm.  
b In order to monitor more of the service problem history, press the SET TEMP  
button. This will change the service problem history number (code number).  
Code number 01 (most recent)…code number 04 (oldest)  
,
( )  
NOTE  
The service problem history keeps four problems in memory.  
c Pressing the  
button will clear the  
entire indoor unit alarm history.  
Pressing the  
button will restore the  
normal operating display.  
c
b
a
c
2081_M_I  
Fig. IV-5  
SM830082  
IV - 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
Important  
Never press  
(clear) button unless you want to erase the accessed data in memory. Follow  
the procedure below only when erasing is necessary.  
To erase accessed data, press the button.  
When erasing is finished,“----” mark appears on the controller’s display.  
CAUTION  
After checking the alarm messages, be sure to press the  
button.  
(D) Check the remote controller itself for correct operation  
The remote controller has a self-diagnostic function to check for problems in the remote  
controller itself.  
In order to check, the shorting plug (2P) inserted in the socket (4P) on the back of the remote  
controller circuit board should be moved from RCU.Main to RCU.CK. (Ref. Fig. IV-6)  
S
NOTE  
1) Be sure that the shorting plug is inserted onto RCU.Main during normal operation.  
2) The remote controller self-diagnostic function can be run on a remote controller  
independently if power of 9–16 VDC is supplied to plug 2P as shown in Figure IV-6.  
(A 12-1/4-W resistor must be placed in between.)  
Checking serial communications  
4
The remote controller’s own serial communications sending and receiving circuits can be  
checked by moving the shorting plug. The indicators will respond as follows for approximately  
10 seconds, then turn off:  
Correct : All indicators light up.  
Incorrect : All indicators flash on and off.  
Checking I/O circuits  
After completing the serial communications check (for 10 seconds), operate each switch on  
the remote controller. If the LCD display responds, then the remote controller is normal.  
TIMER  
TMNL.  
During normal  
operation  
121/4W  
DC9  
~16V  
Shorting plug  
is moved.  
RCU.Main  
RCU.CK  
RCU.Sub  
RCU  
TMNL.  
RCU.ADR  
During self-  
diagnostic check  
2079_M_I  
Fig. IV-6  
SM830082  
IV - 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
Important  
Never press  
(clear) button unless you want to erase the accessed data in memory. Follow  
the procedure below only when erasing is necessary.  
To erase accessed data, press the button.  
When erasing is finished,“----” mark appears on the controller’s display.  
CAUTION  
After checking the alarm messages, be sure to press the  
button.  
(E) Execute the auto. address operation  
Auto. address operation is executed by pressing the A. ADD (S1) button of out-  
door unit’s PCB usually.  
For your convenience it can be executed by remote controller also.  
n  
a Press the  
and  
(
) buttons at the same time for more than 4 seconds. (Fig. IV-7)  
b Set CODE No. A1 with  
,
( ) button.  
In this mode, the auto. address  
operation is executed at each R.C.  
(Refrigerant Circuit) line one by one.  
4
b
a
d
c
1931_M_I  
Fig. IV-7  
c Select R.C. No. which you want to execute the auto. address operation with  
button.  
d Press the  
button. The auto. address operation will start. CODE No. changes from  
flashing to ON state.  
e If an error occurs during operation, the alarm message will be displayed. Check and re-  
move the cause. If you want to stop the operation, press the button then the unit  
stands in waiting mode (Press the button again.)  
f If the automatic address operation finishes, the display will disappear.  
g Execute the operation of the other R.C. line in the same way by following the above steps  
c to d .  
SM830082  
IV - 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
(F) Confirm and change the indoor unit address (Ref. Fig. IV-8, IV-9)  
The purpose of the above function is to let you confirm the indoor unit address after  
the auto. address operation, and change the indoor unit address if it is needed.  
a Press the  
and  
(
) buttons at the same time for more than 4 seconds.  
b Select the R.C. No. which you want to change with the  
(up) or  
(down)  
buttons.  
c Press the  
button (to confirm the R.C. No.).  
The smallest registered indoor No. and the selected R.C. No. will be displayed.  
d Select the indoor No. which you want to change with  
the fan motor of selected indoor unit will turn on and let you confirm the indoor unit  
address.  
button. Once in this mode,  
S
e Set the required new indoor unit’s No. by pressing the  
,
(
) button.  
f Press the button.  
UNIT No, SET DATA (0001) and  
changes from flashing to ON state.  
button.  
g If you made a mistake, press the  
h Finally, press the  
button.  
4
i If you want to change the indoor unit address of the other R.C. No., follow the step ato h  
in the same way.  
h
a
e
c
b
f
1932_M_I  
2077_M_I  
Fig. IV-8  
Fig. IV-9  
SM830082  
IV - 26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
(G) Change the shift temperature in heating mode (Ref. Fig. IV-10)  
If the indoor unit is installed at high location (ex. ceiling level), the thermostat tends to turn off at  
heating mode because of the hot air temperature around ceiling level. In order to solve the  
problem, the shift temp. (valid while heating only) is set when shipped from factory.  
If the shift temp. is not enough (ex. the indoor unit is installed at position higher than 3 m), the  
shift temp. can be set with remote controller from 0 to +10 deg (°F) <from 0 to 20 deg (°F)>.  
manually as follows:  
a Press the  
+
buttons at same time for more than 4 seconds.  
b In case of group control, if you want to change all units in group control collectively, pro-  
ceed next step remaining ALL displayed.  
If you want to change a unit individually, select the indoor unit address (UNIT No.) with  
button.  
c Select the CODE No. 06 with  
,
( ) button.  
n  
d Choose the shift temp with  
,
(
) button.  
e Press the  
button.  
CODE No. 06, SET DATA and  
change from flashing to ON state.  
button.  
f If you made a mistake, press the  
g Finally, press the  
button.  
4
a
d
c
e
b
1933_M_I  
Fig. IV-10  
SM830082  
IV - 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
(H) Set the indoor unit address (Ref. Fig. IV-11, IV-12)  
This function is usable if the auto. address operation is not available.  
Indoor unit address can be set one by one by remote controller in such case.  
NOTE  
1) In case of group control, branch wiring for group control should be removed  
temporarily.  
2) In case of remote controllerless system, remote controller should be connected  
with the indoor unit temporarily.  
(Set the No. of R.C. address)  
b Press the  
c Set the CODE No. 12 to set the No. of R. C. with the  
d Set the No. of R. C. which you want to set with  
e Press the button.  
,
and  
buttons at the same time for more than 4 seconds.  
,
( ) button.  
,
(
) button.  
S
UNIT No., CODE No. 12,  
and SET DATA (0002) change from flashing to ON state.  
(Set the indoor address)  
f Select the CODE No. 13 to set the indoor unit No. with the  
g Set the indoor unit No. which you want to set with the  
h Press the button.  
,
( ) button.  
,
(
) button.  
4
UNIT No., CODE No. 13,  
state.  
and SET DATA (0004) change from flashing to ON  
(Set the group address)  
i Select the CODE No. 14 to set group setting with the  
j Set the No. of group setting with the ) button.  
k Press the button.  
,
( ) button.  
,
(
UNIT No., CODE No. 14,  
and SET DATA change from flashing to ON state.  
l If you made a mistake, press the  
button so that setting returns to the initial state.  
m Press the  
button to finish this mode.  
The display is disappeared.  
n Confirm the indoor unit address (UNIT No.) with the  
button after pressing the  
ON / OFF button.  
o In case of group control, be sure to restore the branch wiring to its original wiring. In  
case of remote controller–less system, remove the remote controller.  
SM830082  
IV - 28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
R.C. address  
1
2
3
d, g,  
j
R.C. address  
1
2
3
1
0
1
0
1
0
Indoor address  
Group address  
c, f,  
i
m
2078_M_I  
e, h, k a  
2080_M_I  
Fig. IV-11  
Fig. IV-12  
( I ) Change the period of the filter timer (Ref. Fig. IV-13)  
n  
If the period of filter timer is not suitable (for example in case of dirty environment), the  
period can be shortened to half as follows:  
a Press the  
+
buttons at same time for more than 4 seconds.  
b In case of group control, if you want to change all units in group control collectively, pro-  
ceed next step remaining “ALL” displayed.  
If you want to change a unit individually, select the indoor unit address (UNIT No.) with  
button.  
4
c Select the CODE No. 02 with  
,
( )  
button.  
d Change the No. from 0000 to 0001 with  
,
(
) button.  
e Press the  
button.  
CODE No. 06, SET DATA and  
change from flashing to ON state.  
f If you made a mistake, press the  
button.  
1934_M_I  
Fig. IV-13  
g Finally, press the  
button.  
SM830082  
IV - 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
Earthed wire  
4-2 Checking the Electrical Components  
Clip  
(1) Measurement of Insulation  
Resistance  
Probe  
• The electrical insulation is acceptable when the  
resistance exceeds 1 M.  
Insulation  
tester  
Fig. IV-14  
0638_X_S  
1
Power Supply Wires  
Terminal plate  
Clamp the earthed wire of the Power Supply wires  
with a lead clip of the insulation resistance tester and  
measure the resistance by placing a probe on either  
of the power wires. (Fig. IV-14)  
S
Probe  
Then measure the resistance between the earthed  
wire and the other power wires. (Fig. IV-14)  
2
Indoor Unit  
Clamp an aluminum plate fin or copper tube with the  
lead clip of the insulation resistance tester and  
measure the resistance by placing a probe on the  
terminal plate (Fig. IV-15)  
4
Clip  
Copper  
tube or  
Insulation  
tester  
metallic part  
3
Outdoor Unit  
Fig. IV-15  
0639_X_S  
Measure the resistance by placing a probe on the  
terminal plate in the same manner as explained  
above 2. (Fig. IV-15)  
Probe  
4
Measurement of Insulation Resistance for  
Electrical parts  
Disconnect the connector of the desired electric part  
Clip  
from terminal plate, P.C.B. Ass’y, etc. (Fig. IV-16)  
Copper  
• Similarly, disconnect the lead wires from  
tube or  
compressor, capacitor, etc. (Fig. IV-17)  
metallic part  
• Measure the resistance in the same manner as  
illustrated on the right.  
Insulation  
tester  
Fig. IV-16  
0640_X_S  
Refer to Electrical Wiring Diagram.  
From fan motor,  
compressor and other  
parts.  
NOTE  
If the probe does not enter the hole because the  
hole is too narrow, use a probe with a thinner pin.  
Probe  
Metallic  
part  
Clip  
Insulation  
tester  
0641_X_S  
Fig. IV-17  
SM830082  
IV - 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
(2) Checking the Protective Devices  
Disconnect the connector, which consists of P (plug) and S (socket) when you want to  
check the protective device.  
Then check continuity among plug’s (and/or socket’s) terminal as in Fig. IV-18.  
Normality of the protective device can be judged by the following table.  
The Protective Device is proved normal if there is a continuity between terminals.  
socket  
n  
Multimeter  
Fig. IV-18  
4
0642_X_S  
1
2
3
Indoor fan motor thermal protector (49FI) . . . . . . Indoor unit  
Disconnect the connector which leads to the indoor fan motor (FMI).  
Check the socket’s terminals.  
Compressor motor thermal protector . . . . . . Outdoor unit  
Disconnect the wires from terminals of compressor.  
Check the terminals of compressor.  
Outdoor fan motor thermal protector (49FO) . . . . . . Outdoor unit  
Disconnect both the connector which leads to the outdoor fan motor (FMO).  
Check socket’s terminal.  
SM830082  
IV - 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
(3) Checking the Electrical Parts  
1
Power transformer (TR1) ..................... Indoor unit *Measure the coil resistance.  
Primary 230-208V ; Measure the resistance between No.1 and No.3  
(WHT lead wires) terminals of 3P (WHT) socket connected to  
power transformer.  
Secondary  
14.8V ; Measure the resistance between No.1 and No.2  
(RED lead wires).  
14.8V ; Measure the resistance between No.3 and No.4  
(BRN lead wires).  
S
Refer to “1-3 Other component specifications”.  
Power transformer (TR) .................... Outdoor unit *Measure the coil resistance.  
2
Primary 230-208V ; Measure the resistance between No.1 and No.3  
(WHT lead wires) terminals of 3P(WHT) socket jointed to power  
transformer.  
Secondary  
14 V ; Measure the resistance between No.1 and No.2  
(BRN lead wires).  
4
Refer to “1-3 Other component specifications”.  
Indoor fan motor (FMI) .........................Indoor unit *Measure the coil resistance.  
3
Measure the resistance between each terminal of 9P (WHT) socket connected to the  
indoor fan motor.  
Refer to “1–2–(A) Major component specifications”.  
4 Outdoor fan motor (FMO) .....................Outdoor unit *Measure the coil resistance.  
Measure the resistance in the same manner as explained above 3.  
Refer to “1–2–(B)Major component specifications”.  
SM830082  
IV - 32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
5
Motor capacitor ............ Both in indoor and outdoor unit  
• Remove the lead wires from the capacitor terminals, and then place a probe on the capacitor  
terminals as shown in Fig. IV-19. Observe the deflection of the pointer, setting the resistanc  
measuring range of the multimeter to the maximum value.  
• The capacitor is “good” if the pointer bounces to a great extent and then gradually returns to  
its original position.  
NOTE  
The range of deflection and the deflection time  
differ according to the capacity of the capacitor.  
n  
Multimeter  
4
Compressor motor  
capacitor  
Fan motor  
capacitor  
1041_X_S  
Fig. IV-19  
6
Continuity of fuse on P.C.B. Ass’y  
Check for continuity using a multimeter  
as shown in Fig. IV-20.  
Fuse  
NOTE  
Method Used to Replace Fuse on PCB Ass’y  
1. Remove the PCB Ass’y from the electrical compo-  
nent box.  
1042_X_S  
Fig. IV-20  
Soldering iron  
2. Remove the fuse from PCB Ass’y using pliers while  
heating the soldered leads on the back side of the  
PCB Ass’y with a soldering iron (30W or 60W).  
(Fig. IV-21)  
PCB Ass’y  
Fuse  
3. For replacement, insert a fuse of the same rating to  
the intended position and solder it.  
Varistor  
(Allow time to radiate heat during soldering so that  
the fuse does not melt.)  
When replacing the fuse, be  
Pliers  
CAUTION  
sure not to break down the  
varistor.  
1043_X_S  
Fig. IV-21  
SM830082  
IV - 33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
7
8
9
Solenoid coil of the electronic refrigerant  
*Measure the coil resistance.  
control valve (ERCV) ………… Indoor unit  
Measure the resistance between No. 5 (GRY lead wire) and other terminals (another color of  
lead wires) of 5P (WHT) plug connected to the solenoid coil.  
Refer to “1-2-(A) Major component specifications”.  
Compressor motor (CM) ……… Outdoor unit  
In case of single -phase compressor  
*Measure the coil resistance.  
Remove the cover of compressor terminal and measure the resistance  
between terminals.  
S
Refer to “1-2 Major component specifications”.  
Compressor motor magnetic contactor (52C) ………… Outdoor unit  
Measure the resistance between A (ORG lead wire) and B (GRY lead wire) terminals on  
the compressor motor magnetic contactor.  
Refer to “1-3 Other component specifications”.  
Check the continuity between contactors.  
4
FMCA–1UL  
MODEL  
Push button on  
the magnetic  
contactor  
Pair of terminals  
R – U S – V T – W 31 – 32  
no press  
press  
––––  
YES  
––––  
YES  
––––  
YES  
YES  
––––  
0
Solenoid coil of 4-way valve (20S) … Outdoor unit  
*Measure the coil resistance.  
Measure the resistance between No.1 (BLK lead wire) and No.2 (BLK lead wire) terminals  
of 2P (BLK) socket connected to the solenoid coil.  
Refer “1-3 Other component specifications”.  
SM830082  
IV - 34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
(4) Thermistor Characteristic Curv  
(2) Indoor heat exch.  
coil sensor  
(1) Room temp. sensor : TH1 (KTEC-35)  
: TH2(E1), TH3(E2)  
Outdoor heat  
exch. coil sensor : TH6(C1), TH7(C2)  
( PBC-41E)  
40  
n  
35  
10  
9
8
7
6
5
4
3
2
1
30  
25  
20  
15  
10  
4
5
0
–4  
5
14  
23  
32  
41  
50  
59  
68  
50  
59  
68  
77  
86  
95 104  
Temperature (°F)  
1045_M_I  
Temperature (°F)  
1044_M_I  
(3) Compressor discharge gas temp. sensor : TH8 (PTC-51H)  
7
6
5
4
3
2
1
176  
194  
212  
230  
248  
266  
Temperature (°F)  
1149_THS_I  
SM830082  
IV - 35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
(5) PCB Setting  
Setting of outdoor control PCB  
(A) Standard control (single outdoor unit)  
In case of single outdoor unit installation, even if  
in case of twin, triple or quartet type (2, 3 or 4  
indoor units), no setting necessary.  
Keep factory shipment state (R.C. address is set  
in “0”).  
S
In this case, auto. address operation takes place  
automatically for the first time when the power is  
switched on. This takes about a few minutes.  
(B) Group control (Multiple outdoor units)  
In case of group control (up to 8 indoor units can  
be connected with one remote controller), before  
turning the power supply on set the R.C. address  
with S2, S3 on the outdoor control PCB.  
4
R.C. address: Refrigerant circuit address 1 ~ 30.  
(C) Central control (when using the system  
controller)  
In case of central control (when using the system  
controller,that is, when linking outdoor units in a  
network),  
(a) Before turning the power supply on, set the  
R.C. address with S2, S3 on the outdoor  
control PCB.  
(b) Remove the short plug (CN006, 2P Black)  
from all outdoor units except any one of  
outdoor unit.  
Setting of indoor control PCB  
No setting necessary.  
Each indoor unit address (UNIT No.: R.C. – No.) is decided after auto. address operation.  
Indoor unit No.  
Refrigerant Circuit No. (R.C. address)  
Manual setting for indoor unit address can be performed also by remote controller.  
SM830082  
IV - 36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
(6) R.C. Address Setting Method  
Outdoor unit R.C. address setting method  
In case of group control or central control, set the R.C. address to 1, 2, 3, ... according to the No. of outdoor  
units.  
Outdoor control PCB  
CN006 (2P Black)  
Refrigerant circuit address  
(factory setting = 0)  
n  
Refrigerant circuit address (black)  
0
: S2  
Refrigerant circuit address  
(2P DIP switch, green or Blue)  
10  
20  
position position  
ON  
ON side  
: S3  
OFF side  
A. ADD (S1):  
Automatic address setting start button  
Used for central control (link system)  
1
2
and group control (Normally, not used)  
4
2093_C_I  
R.C. address  
(S3 2P dip switch, green or blue)  
R.C. address  
R.C. address  
(S2 Rotary switch, Black)  
ON  
ON side  
0
00 auto address  
(“0” when shipped from factory)  
Both OFF  
Set to 0  
1
2
OFF side  
SM830082  
IV - 37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
(7) Automatic Address Setting Method  
(8) Displaying Indoor / Outdoor Unit Com-  
bination Numbers  
— For group control and central control with multiple  
outdoor units —  
Display the indoor / outdoor unit address after auto-  
matic address setting.  
Carry out automatic address setting with the  
remote controller.  
(1) All auto. address operation  
(1) When installing multiple units, match the indoor  
unit address numbers and the outdoor R.C.  
address numbers and display them at an easy-to-  
check location (near the nameplate) with an oil-  
based magic marker or other indelible marker so  
that the individual indoor and outdoor unit combi-  
nations can be checked.  
1
Press the  
the same time for more than 4 seconds.  
Press the button after confirming the  
and  
(
) buttons at  
2
S
CODE No. AA (CODE No. AA: All Auto.  
address operation).  
After addresses are automatically set in  
order for the outdoor units from No. 1 to No.  
30, the system returns to the normal  
stopped state.  
Example:  
Outdoor Unit 1 – Indoor Units 1-1, 1-2, 1-3, ....  
Outdoor Unit 2 – Indoor Units 2-1, 2-2, 2-3, ....  
(2) Individual auto. address operation for each  
refrigerant circuit  
(2) This is necessary for maintenance. Always label  
these.  
1
To select each refrigerant circuit individually  
and set addresses automatically, press the  
*Check indoor unit address with the remote  
4
controller. Press the  
button for at least 4  
and  
time for more than 4 seconds, then press  
the ) button once to set  
CODE No. A1.  
(
) buttons at the same  
seconds and check the indoor unit address with  
the  
button. (Each time you press the  
,
(
button, the address changes 1-1, 1-2, ...  
2-1, 2-2, ...) The fan for only the selected indoor  
unit turns on at high speed, so check which  
indoor unit runs and label the indoor unit address.  
(If there is 1 outdoor unit, the addresses are 1-1,  
1-2, ...)  
(CODE No. A1: Auto. address operation)  
2
3
4
Select R.C. No. which you want to execute  
the auto. address operation with  
button.  
Press the  
button. The auto. address  
When you press the  
button again, the system  
operation will start. CODE No. changes from  
flashing to ON state.  
returns to normal remote control mode.  
If the error is happened during the operation,  
the alarm message will display. Check and  
remove the cause. If you want to interrupt  
the operation, press the  
button then the  
unit stands in waiting mode (Press the  
button).  
5
6
If the auto. address operation finishes, the  
display will disappear.  
Execute the operation of the other R.C. line  
in the same way by following the above  
steps 2 to 3.  
7
Complete the auto. address operation by  
pressing the  
button.  
NOTE  
Required time for auto. address operation:  
In case of group control : a few minutes for each R.C.  
In case of central control : max. about 20 min. for  
each R.C.  
SM830082  
IV - 38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
(9) Items to Check Prior to Test Run  
(1) Turn on the power supply switch more than 5 hours before in order to charge the crank case heater.  
(2) Fully open the outdoor service valve after making the leak inspection of field connected tubing, vacuuming,  
and gas charging if necessary.  
(3) Check the capacity code setting.  
*
*
The factory setting is as shown in the table. Double check it.  
The capacity code is set by S4 (green or blue, 4P DIP switch) on outdoor control PCB.  
n  
Outdoor control PCB  
4
S4 (green or Blue) capacity code  
(4P DIP switch)  
ON  
ON side  
1
2
3
4
OFF side  
2094_C_I  
S4. Capacity code  
No.  
Outdoor PCB  
Model No.  
24 type  
1
2
3
4
ON ON ON OFF  
OFF ON OFF ON  
ON ON OFF ON  
36 type  
48 type  
SM830082  
IV - 39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
(10) Test Run  
Preparing for Test Run  
ON  
Before attempting to start the air conditioner,  
(Power must be turned ON  
at least 5 hours before  
attempting test run)  
check the following:  
(1) All loose matter is removed from the cabinet  
especially steel filings, bits of wire, and clips.  
(2) The control wiring is correctly connected and all  
electrical connections are tight.  
Power mains switch  
0765_C_I  
(3) The protective spacers for the compressor used  
for transportation have been removed. If not,  
remove them now.  
Fig. IV-22  
S
Narrow tube service  
valve (3-way valve)  
(4) The transportation pads for the indoor fan have  
been removed. If not, remove them now.  
(5) The power has been connected to the unit for at  
least 5 hours before starting the compressor. The  
bottom of the compressor should be warm to the  
touch and the crankcase heater around the feet  
of the compressor should be hot to the touch.  
(Fig. IV-22)  
Wide tube service  
valve (ball valve)  
4
Fully OPEN  
Fully OPEN  
(6) Both the wide and narrow tube service valves are  
open. If not, open them now. (Fig. IV-23)  
1371_C_I  
Fig. IV-23  
Test run procedure  
The purpose of the test run function is to let you control the operation of the unit directly without the  
thermostat turning the unit on or off. As indicated in the following procedure, switch out of TEST  
RUN when you are finished, or the air conditioner can be damaged because it will not cycle on and  
off normally.  
To protect the air conditioner from overloading, the outdoor unit will not start running for 3 minutes  
after power is applied or the unit is turned OFF.  
a
b
c
d
e
Press the  
controller. (Fig. IV-24)  
(TEST RUN) button on the remote  
Alarm message  
Press the  
to start the test run.  
(ON / OFF operation) button  
Press the  
COOL or HEAT mode.  
(MODE) button to select either  
When the test run has started, “TEST” shows on  
display of the remote controller.  
During the test run, the air conditioner runs  
continuously and the thermostat does not control  
the system.  
f
After the test run, press the  
button once  
again to cancel this mode and check that “TEST”  
is not shown on the display.  
The TEST RUN button is  
used only for servicing the  
air conditioner. Do not press  
this button for normal  
operation, or the system  
may be damaged.  
CAUTION  
TEST RUN/CHECK  
button  
ON/OFF operation MODE button  
button  
2057_C_I  
Fig. IV-24  
SM830082  
IV - 40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
Test Run Procedure  
Start  
Yes  
Turn on RCU address SW  
of sub remote control unit  
Multiple remote  
control?  
No  
Recheck the test items before test operation.  
Check the indoor and outdoor unit combination (wiring).  
n  
Single type?  
Multiple indoor  
units for one outdoor  
units?  
Yes  
Yes  
(One indoor unit and one  
remote controller for one  
outdoor unit)  
No  
Turn on power supply for indoor units side  
first Then turn on power supply for outdoor  
unit side.  
No  
Group control  
for multiple outdoor  
units?  
Yes  
Set the outdoor unit R.C. address.  
Turn on power supply switch.  
Go next  
R.C. line  
4
No  
Press A. ADD (S1) button (See P87).  
or  
Execute auto. address operation with the  
remote controller.  
No  
Yes  
Finish all  
R.C. line?  
Central control  
for multiple outdoor  
units?  
Yes  
CN4: Open (*)  
Set the outdoor unit R.C. address.  
Turn on power supply switch.  
Go next  
R.C. line  
No  
Press A. ADD (S1) button (See P87).  
or  
No  
Execute auto. address operation with the  
remote controller.  
Yes  
Finish all  
R.C. line?  
Display the combination number.  
Set the remote controller to test operation.  
No  
Check according the self-diagnostics function table,  
see Sec. 12-8, 9, 10, and if there is a location to correct,  
correct it.  
Is operation possible?  
Note: Check the indoor side drain water.  
Yes  
Return the remote controller to normal.  
End  
NOTE  
2231_M_I  
1) One of CN006 of all linked outdoor units shold be short.  
2) In case of using system controller, zone registration is required after finishing Test run.  
Regarding the zone registration, please refer to page 74 and 75.  
SM830082  
IV - 41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
(11) PCBs and Their Location  
PCB (CR-TH2442) FOR INDOOR UNITS  
CN77 (GRN) : LM  
CN74 (WHT) : RS2  
F2 : Fuse 250V / 5A  
CN85 (BLU) : DPH  
CN78 (BLU) : DP  
F1 : Fuse 250V / 5A  
CN73 (BLK) : RS1  
S
CN81 (GRY) : T20  
CN80 (RED) : 26H  
CN83 (WHT) : FM  
CN75 (WHT) : VCC  
4
CN201 (WHT) : FAN DRIVE  
CN8 (WHT) : LS  
CN6 (RED) : EXCT  
CN9 (RED) : FS  
D80 LED : POW  
CN71 (YEL) : T10  
CN33 (YEL) : ROOM TEMP  
E2P-ROM  
CN31 (RED) : COIL E1  
CN70 (WHT) : T6  
CN91 (WHT) : CRV  
CN32 (BLK) : COIL E2  
CN2 (WHT) : TEST  
CN3 (WHT) : TMX60  
CN5 (WHT) : CHK  
CN30 (BRN) : COIL E3  
CN35 (GRN) : PNL  
CN44 (BRN) : EMG  
CN40 (BLU) : OC  
CN1 (WHT) : DISP  
F3 : Fuse 0.5A  
CN41 (BLU) : RC  
CN42 (BLU) : WL  
2124_C_S  
SM830082  
IV - 42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
PCB (CR-CH2442) FOR OUTDOOR UNITS  
CN013 (WHT) : CK. H  
CN012 (WHT) : CK. L  
CN011 (RED) : TEST  
CN008 (WHT)  
CN023 (GRN) : DISCH  
CN022 (RED) : C2  
CN021 (BLK) : C1  
CN003 (WHT) : VCC  
n  
CN026 (YEL)  
: TMX60  
CN007 (RED)  
: EXCT  
CR-CH2442  
S001 (A. ADD)  
: Auto address  
CN025 (WHT) : CT1  
D015 LED : POW  
S004 (BLU)  
: Capacity code  
4
CN004 (BLU) : OC  
S003 (BLU)  
: R.C. address  
CN005 (BRN) : EMG  
S002 (BLK)  
: R.C. address  
F003 : Fuse  
125V / 0.5A  
CN100 (BLK) : JM  
CN015 (YEL) : 20S  
CN016 (BLK) : 52C  
CN002 (WHT) : RS  
F002 : Fuse 250V / 3A  
CN001 (BLU) : SUP  
CN017 (RED) : 63PH  
F001 : Fuse 250V / 3A  
2178_C_I  
SM830082  
IV - 43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
(12) Checking procedure for each PC Board  
The indoor and outdoor PCBs have functions to check the signal transmission and reception of the  
serial circuit and to check the microcomputer operation. (Self-diagnosis function)  
Precautions required when checking  
1. After turning off the power to the indoor (outdoor) unit, remove the inter-unit control wiring (U1-U2)  
and create a short-circuit between U1 and U2.  
2. Short the CHECK PIN on the PC board of the indoor (outdoor) unit and turn on the power.  
3. When checking the Outdoor controller, remove the compressor wiring from the compressor  
electromagnetic contactor.  
S
4-1. Checking the serial circuit  
Indoor controller: A lighted LED indicates normal. A blinking LED indicates abnormal.  
Outdoor controller: Blinking LEDs (D11 and D22) indicate normal. If one of the LEDs (D11 and D22)  
goes off, it indicates abnormal.  
4-2. Checking microcomputer operation  
When the microcomputer works normally, the relays are switched in sequence as below.  
4
Indoor controller  
Output  
ON time  
Indoor fan Very high fan speed (HH) 0.5 seconds  
Indoor fan High fan speed (H)  
Indoor fan Low fan speed (L)  
Indoor fan Very low fan speed (LL)  
Flap motor  
0.5 seconds  
0.5 seconds  
0.5 seconds  
0.5 seconds  
0.5 seconds  
0.5 seconds  
0.5 seconds  
0.5 seconds  
0.5 seconds  
0.5 seconds  
0.5 seconds  
0.5 seconds  
Drain pump  
Operation order Electric heater  
Operation signal  
In a lump  
Electronic control valve A  
Electronic control valve B  
Electronic control valve.A  
Electronic control valve B  
Outdoor controller  
Output  
ON time  
Outdoor fan High fan speed (H)  
Outdoor fan Low fan speed (L)  
4-way valve  
0.5 seconds  
0.5 seconds  
0.5 seconds  
0.5 seconds  
Operation order  
Compressor  
SM830082  
IV - 44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Service procedures  
(13) TMX60 pins  
When shorting TMX60 pins on the indoor and outdoor PCBs, operations shown on the above table will be per-  
formed on each indoor and outdoor unit. Use TMX60 pins to perform a quick check.  
NOTE  
• When checking pin operation, stop the indoor and outdoor units with the remote control unit.  
Shorting CK.L or CK.H pin of the outdoor PCB  
When shorting the cooling pin (CN8) with normal operation  
n  
• Relay RY3 is turned ON for 3 seconds  
• Relay RY4 is turned ON for 3 seconds  
The outdoor fan motor operates at the “LL” fan speed.  
The outdoor fan motor oprates at the “H” fan speed.  
• Turn ON relay RY2 under the above condition The magnet switch (52C) turns ON.  
It will take about 18 seconds before cooling operation begins.  
Shorting the heating pin (CN9) with normal operation  
• Relays RY3 and RY4 are turned ON for 3 seconds The outdoor fan motor operates at the “H” fan speed.  
• Relay RY3 is turned ON for 3 seconds  
The outdoor fan motor operates at the “LL” fan speed.  
The magnet switch (52C) turns ON. If relay RY1 is  
turned ON, the 4-way valve (20S) turns ON.  
• Turn ON relay RY2 under the above conditions  
4
It will take about 18 seconds before heating operation begins.  
NOTE  
• The outdoor unit operates independently regardless of the indoor unit’s operation. However, the outdoor unit  
does not defrost.  
• The indoor and outdoor units stop when the outdoor protection apparatus activates during the checking  
operation, and automatically restarts, unlike in normal operation.  
SM830082  
IV - 45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANYO FISHER Service Company  
CENTRAL REGION  
1739 Sands Place, Suite G  
Marietta, GA 30067  
Phone: (770) 951-8284  
Fax: (770) 951-2077  
July. / ’01  
Printed in U.S.A.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Raypak Automobile 504 2004 User Guide
Razor Pet Fence 10067112 User Guide
RCA Flat Panel Television J20L743 User Guide
Reebok Fitness Home Gym RBBE07870 User Guide
Rolls Music Mixer RP262 User Guide
Ryobi Lawn Mower RY14110 User Guide
Sanyo Projector Accessories AH 23511 User Guide
Scytek electronic Automobile Alarm 1000RS DBP User Guide
Sega Video Games 10086670011 User Guide
Senco Nail Gun SCN200 User Guide