		 AW06EDB Series   
					Air Conditioner   
					user manual   
					imagine the possibilities   
					Thank you for purchasing this Samsung product.   
					To receive more complete service, please   
					register your product at   
					
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				safety information   
					To prevent electric shock, disconnect the power before servicing, cleaning, and installing the unit.   
					SAFETY INFORMATION   
					Before using your new air conditioner, please read this manual thoroughly to ensure that you know how to   
					safely and efficiently operate the extensive features and functions of your new appliance.   
					Because the following operating instructions cover various models, the characteristics of your air   
					conditioner may differ slightly from those described in this manual. If you have questions, call Samsung’s   
					
					What the icons and signs in this user manual mean:   
					Risk of death or serious personal injury.   
					WARNING   
					Potential risk of personal injury or material damage.   
					CAUTION   
					To reduce the risk of fire, explosion, electric shock, or personal injury when   
					using your air conditioner, follow these basic safety instructions:   
					CAUTION   
					Do NOT attempt.   
					Do NOT disassemble.   
					Do NOT touch.   
					Follow directions carefully.   
					Unplug the power plug from the wall socket.   
					Make sure the machine is grounded to prevent electric shock.   
					Call the contact center for help.   
					Recommended instructions or useful information.   
					These warning signs are here to prevent injury to you and others.   
					Please follow them carefully.   
					After reading this section, keep it in a safe place for future reference.   
					SEVERE WARNING SIGNS   
					Do not cut the power plug and connect to a different power cable.   
					Never attempt to lengthen the power cable.   
					• Potential risk of fire or electric shock.   
					Do not yank the power cable and touch the power plug with wet hands.   
					• Potential risk of fire or electric shock.   
					Never use a damaged power plug, power cable, or loosened power   
					receptacle.   
					• Potential risk of fire or electric shock.   
					safety information _03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				safety information   
					Do not place the air conditioner near hazardous substances or equipment   
					that releases free flames to avoid fires, explosions or injuries.   
					Do not spray flammable gases such as insecticide near the air conditioner.   
					• Potential electric shock, fire or unit malfunction.   
					Do not block or place items in front of the air conditioner.   
					Do not step, hang onto, or place heavy items on the air conditioner.   
					• Potential risk of personal injury.   
					Do not insert anything such as fingers or branches into the air conditioner   
					vents.   
					• Keep children away from the air conditioner.   
					• Potential risk of personal injury.   
					Potential risk of unit malfunction, water leakage, electric shock, or fire.   
					Install the air conditioner with the support bracket securely fastened to use   
					for an extended period of time.   
					• If the air conditioner falls, it may cause personal injury or loss of property.   
					Ensure the air conditioner is installed in compliance with current national   
					safety standards.   
					Use a rated circuit breaker only.   
					• Never use steel wires or copper wires as a circuit breaker. It may cause fire or unit   
					malfunction.   
					Use an exclusive power source for the air conditioner.   
					• Potential risk of electric shock or fire.   
					Do not put undue stress on the power cable or place heavy objects on it.   
					Do not bend the power cable excessively.   
					• Potential risk of fire or electric shock.   
					If the air conditioner becomes wet, turn off immediately and call Samsung’s   
					contact center at 1-800-SAMSUNG.   
					• Potential risk of fire or electric shock.   
					Disconnect the air conditioner from power supply before it is repaired or   
					disassembled.   
					Use a receptacle that has a ground terminal. The receptacle must be used   
					exclusively for the air conditioner.   
					• Improper electrical grounding may cause electric shock or fire.   
					04_ safety information   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				CAUTION SIGNS   
					Ensure no water gets into the air conditioner.   
					• Potential risk of fire or electric shock.   
					Do not install the air conditioner close to heating appliances to avoid damage.   
					Turn off the air conditioner using the provided remote control or control accessory   
					(if provided). Do not unplug to turn the unit off (unless there is an immediate   
					danger).   
					Do not open the front grille during operation.   
					• Potential risk of electric shock or unit malfunction.   
					Cool air should not flow directly towards people, pets, and plants.   
					• It is harmful to your health, pets, and plants.   
					Do not run the air conditioner for an extended period of time in an   
					unattended room with the door closed where babies,elderly or disabled   
					people are located.   
					• Open the door or windows to ventilate your room at least once an hour to prevent oxygen   
					shortage.   
					Do not use the air conditioner as a cooling precision instrument for food,   
					pets, plants, cosmetics or machinery.   
					• Potential risk of property loss.   
					Do not drink water from the air conditioner.   
					• Potential risk of health hazard.   
					Do not give excessive shock to the air conditioner.   
					• Potential risk of fire or unit malfunction.   
					Do not expose the dust filter to direct sunlight while drying.   
					• Strong direct sunlight may deform the dust filter.   
					Do not spray water directly on the air conditioner or use benzene, thinner, or   
					alcohol to clean the surface of the unit.   
					• Potential risk of electric shock or fire.   
					• Potential risk of damage to the air conditioner.   
					Do not place containers with liquid or other objects on the unit.   
					Do not throw the remote control.   
					• It may break and plastic piece can be dangerous. You may get a cut or greater injury.   
					The air conditioner is composed of moving parts. Keep children away from   
					the unit to avoid physical injury.   
					Make sure the voltage and frequency of the electric system are compatible   
					with the air conditioner.   
					Insert the dust filter before operating the air conditioner.   
					• If there is no dust filter inside the air conditioner, accumulated dust may shorten the life of   
					the air conditioner and cause electricity waste.   
					Keep indoor temperatures stable and not extremely cold, especially where   
					there are children, elderly or disabled people.   
					Clean the air conditioner after the inner fan stops operating.   
					• Potential risk of injury or electric shock.   
					Clean the dust filter every 2 weeks. Clean the filter more frequently if the air   
					conditioner is operated in dusty areas.   
					safety information _05   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				safety information   
					Have a qualified service technician inspect the condition,electric   
					connections,pipes and external case of the air conditioner regularly.   
					Do not open doors and windows in the room being cooled during operation   
					unless necessary.   
					Do not block the air conditioner vents.   
					• If objects block the air flow, it may cause unit malfunction or poor performance.   
					The packaging material and used batteries of the remote control (optional)   
					must be disposed of in accordance with the national standards.   
					The refrigerant used in the air conditioner must be treated as chemical waste.   
					Dispose the refrigerant following national standards.   
					Have a qualified service technician install the air conditioner and perform a trial   
					operation.   
					Ensure the off-on and protection switches are properly installed.   
					Do not use the air conditioner if damaged. If problems occur, immediately   
					stop operation and disconnect the plug from the power supply.   
					If the air conditioner will not be used for an extended period of time (for   
					example, over several months), unplug the power from the wall.   
					Call Samsung’s contact center at 1-800-SAMSUNG if repairs are needed.   
					• Potential risk of fire or electric shock if disassembly or repairs are attempted by   
					a non-qualified service technician.   
					If you smell burning plastic, hear strange sounds, or see smoke coming from   
					the unit, unplug the air conditioner immediately and call Samsung’s contact   
					center.   
					• Potential risk of fire or electric shock.   
					06_ safety information   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				contents   
					SETTING UP YOUR AIR CONDITIONER   
					BEFORE USE   
					08 Checking the parts and the control panel   
					08   
					09   
					10   
					11   
					11   
					Main parts   
					Control panel   
					Digital display   
					Remote control   
					Installing the batteries   
					08   
					12 Selecting operation mode   
					OPERATING YOUR AIR COND1ITION2ER   
					12   
					13   
					14   
					Cooling   
					Dry   
					Air circulation   
					15 Adjusting air flow direction   
					15 Horizontal air flow   
					16 Advanced functions   
					16   
					17   
					18   
					19   
					On timer   
					Off timer   
					Good Sleep mode   
					Energy Saving mode   
					20 Cleaning the exterior   
					20 Cleaning the air filter   
					20 Maintaining the air conditioner   
					CLEANING AND MAINTAINING YOUR   
					AIR COND2ITION0ER   
					21 Troubleshooting   
					21 Operation ranges   
					APPENDIX   
					21   
					contents _07   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				setting up your air conditioner   
					before use   
					Congratulations on the purchase of your new air conditioner. We hope you enjoy the features of your air   
					conditioner and stay cool with optimal efficiency.   
					Please read the user manual to get started and to obtain the best performance from the air conditioner.   
					CHECKING THE PARTS AND THE CONTROL PANEL   
					Carefully unpack your air conditioner, and check the unit to make sure it is not damaged.   
					Main parts   
					Air inlet (Outside)   
					Inner Air Flow Blades   
					(right/left orientation)   
					Air Outlet   
					Front Grille   
					Air Inlet (Outside)   
					Air Filter (Inside)   
					Power Plug   
					(The type of power plug may   
					differ,depending on the local   
					power supply.)   
					• Your air conditioner may slightly differ from illustration shown above depending on your   
					model.   
					• Power plug may be different from the illustration shown above depending on your region.   
					• When you connect the power plug into the receptacle, a beep will sound.   
					08_ setting up   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Control panel   
					1 
					2 
					3 
					8 
					7 
					6 
					4 
					5 
					Sets the operation mode to Cool, Fan or Dry.   
					Cool - Gets cool air from the air conditioner.   
					Fan - Air circulation with no cooling.   
					Dry - Removes humidity from the room without changing the   
					temperature.   
					MODE BUTTON   
					1 
					Sets E.Saver mode to save energy when the air conditioner is   
					running.   
					Press this button to active/deactive the E.Saver mode when the   
					unit runs in Cool or Fan mode.   
					E.SAVER   
					BUTTON   
					2 
					3 
					In Good Sleep mode, the air conditioner will run for 8 hours at   
					the temperature you set before turning off.   
					GOOD SLEEP   
					BUTTON   
					Press this button to activate/deactivate the Good Sleep mode   
					when the air conditioner is on.   
					Sets the timer to turn the air conditioner on/off automatically   
					after a pre-set time has elapsed.   
					Press this button while the air conditioner is off to activate the On   
					timer.   
					Press this button while the air conditioner is on to activate the Off   
					timer.   
					TIMER BUTTON   
					4 
					5 
					This button adjusts how much air flows through the air   
					conditioner.   
					FAN SPEED   
					BUTTON   
					Sets the fan speed to Low/Medium/High.   
					Turns the air conditioner on and off.   
					A Short beep will sound twice when the air conditioner is turned   
					on.   
					A Long beep will sound once when the air conditioner is turned   
					off.   
					POWER   
					BUTTON   
					6 
					7 
					8 
					REMOTE   
					CONTROL   
					SENSOR   
					Aim the remote control toward this spot on the air conditioner.   
					You can adjust the temperature between 18˚C~30˚C in Cool   
					mode.   
					TEMPERATURE   
					BUTTON   
					 - Increases the temperature by 1˚C unit.   
					 - Decreases the temperature by 1˚C unit.   
					setting up _09   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				setting up your air conditioner   
					before use   
					Digital display   
					Fan speed   
					One of these icons will appear on the display when you press the Fan Speed button on the   
					control panel.   
					Low fan speed.   
					Medium fan speed.   
					High fan speed.   
					Temperature/Timer reminder   
					Temperature/Timer reminder indicates the temperature you have set or the remaining hours left   
					in your Timer and the Sleep mode.   
					Operating mode   
					One of these icons will appear on the display when you press the Mode button on the control   
					panel.   
					Cool mode is activated.   
					Fan mode is activated.   
					Dry   
					When the air conditioner is running in Dry mode, it will decrease the humidity of the room.   
					Timer   
					When you activate Timer or Sleep mode, this icon will appear to let you know that selected   
					mode has been set .   
					E.Saver   
					When you activate E.Saver mode, this icon will appear and the unit will run in energy saving   
					mode.   
					10_ setting up   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Remote control   
					Timer   
					Sets the timer on/off.   
					Temp   
					Increases/decreases the   
					temperature.   
					(See pages 16~17 for instructions.)   
					Good Sleep   
					Sets the Good Sleep mode on/off.   
					(See page 18 for instructions.)   
					Fan   
					Adjusts the fan speed.   
					Mode   
					Sets the Fan/Cool/Dry mode.   
					(See pages 12~14 for instructions.)   
					E.Saver   
					Sets the E.Saver mode.   
					(See page 19 for instructions.)   
					Power   
					Turns on/off the air conditioner.   
					Installing the batteries   
					1. Slide the cover on the   
					rear of the remote   
					2. Install two AAA   
					batteries.   
					3. Close the cover by   
					sliding it back to its   
					original position.   
					control down to open.   
					Check and match the “+”   
					and “-” signs accordingly.   
					Make sure you have   
					installed the batteries in   
					correct position.   
					You should hear a click   
					when the cover is locked   
					properly.   
					setting up _11   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				operating your air conditioner   
					SELECTING OPERATION MODE   
					Cooling   
					Transform a hot and humid room into a cool haven quickly by closing all unnecessary openings   
					such as fireplace dampers, doors, or windows in the room before running the air conditioner to   
					increase efficiency and save energy.   
					1. Turn on the air conditioner.   
					Press the Power   
					button on the remote control.   
					You will hear two short beeps and the air   
					conditioner will turn on.   
					2. Set the operating mode.   
					Press the Cool button on the remote control to   
					select Cool mode.   
					icon will appear on the display.   
					3. Set the temperature.   
					Press the Temp button on the remote control.   
					Press  or  button to increase or decrease the   
					desired temperature.   
					You can set the desired temperature within the   
					range of 18˚C~ 30˚C in Cool mode.   
					You can increase/decrease the temperature in 1˚C units.   
					4. Set the fan speed.   
					Press the Low/Med/High button on the remote   
					control.   
					One of the following icons will appear on the display.   
					Low fan speed is activated.   
					Medium fan speed is activated.   
					High fan speed is activated.   
					• When you are using the remote control, make sure corresponding icon appears on the   
					display.   
					• If current outside temperatures are much higher than the selected indoor temperature,   
					it may take time to bring the inner temperature to the desired coolness.   
					• Air flow can also be adjusted manually. (See page 15 for instructions.)   
					• Avoid drastically turning down the temperature. Energy is wasted and the room does not   
					cool faster.   
					12_ operating   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				operating your air conditioner   
					SELECTING OPERATION MODE   
					Dry   
					If the atmosphere in your room is very humid or damp,you can remove excess humidity without   
					lowering the room temperature too much.   
					1. Turn on the air conditioner.   
					Press the Power   
					button on the remote control.   
					You will hear two short beeps and the air   
					conditioner will turn on.   
					2. Set the operating mode.   
					Press the Dry button on the remote control to   
					select Dry mode.   
					icon will appear on the display.   
					3. Set the temperature.   
					Press the Temp button on the remote control.   
					Press  or  button to increase or decrease the   
					desired temperature.   
					You can set the desired temperature within the   
					range of 18˚C~ 30˚C in Cool mode.   
					You can increase/decrease the temperature in 1˚C units.   
					• When you are using the remote control, make sure corresponding icon appears on the   
					display.   
					• Air flow can also be adjusted manually. (See page 15 for instructions.)   
					operating _13   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				operating your air conditioner   
					SELECTING OPERATION MODE   
					Air circulation   
					If the room is stuffy and stale, operate your air conditioner in Fan mode. The air conditioner will   
					reduce humidity without changing the inner temperature. We recommend using this mode during   
					especially humid, but cool spring days.   
					1. Turn on the air conditioner.   
					Press the Power   
					button on the remote control.   
					You will hear two short beeps and your air   
					conditioner will turn on.   
					2. Set the operating mode.   
					Press the Fan button on the remote control to   
					select Fan mode.   
					icon will appear on the display.   
					3. Set the fan speed.   
					Press the Low/Med/High button on the remote   
					control.   
					One of the following icons will appear on the display.   
					Low fan speed is activated.   
					Medium fan speed is activated.   
					High fan speed is activated.   
					• When you are using the remote control, make sure the corresponding icon appears on   
					the display.   
					• Air flow can also be adjusted manually. (See page 15 for instructions.)   
					14_ operating   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ADJUSTING THE AIR FLOW DIRECTION   
					Air flow can be adjusted in a desired direction.   
					Horizontal air flow   
					1. Adjust the inner air flow blades to the desired position by sliding them side to side.   
					operating _15   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				operating your air conditioner   
					ADVANCED FUNCTIONS   
					This advanced function allows you to turn on/off your air conditioner on/off automatically .   
					Simply set the time and your air conditioner will turn on/off automatically even when you are not home.   
					On timer   
					This function allows you to turn on the air conditioner automatically within the time range of 24   
					hours. The On timer function will only work when the unit is not operating.   
					1. Turn off the air conditioner.   
					Press the Power   
					button on the remote control.   
					2. Set the number of hours you want to delay the start   
					fo the air conditioner.   
					Press the Timer button on the remote control.   
					Each time you press the button, time will increase   
					in hourly units and you can be set up to 24 hours.   
					icon will appear on the display.   
					3. Set the operating mode.   
					Press one of the Mode buttons to select Cool or   
					Fan mode on the remote control.   
					• Temperature/Fan speed can also be adjusted. (See steps 3~4 on page 12 for   
					instructions.)   
					• After the completing the setup,all icons except the remaining hour and   
					approximately 5 seconds later.   
					icon will go off   
					To deactivate the On timer   
					1. Press the Timer button on the remote control   
					until you see   
					on the display.   
					Timer will be off and the icons will disappear   
					momentarily.   
					The air conditioner will remain off.   
					This function will only work while your air conditioner is off.   
					16_ operating   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Off timer   
					This function allows you to turn off the air conditioner automatically within the time range of 24   
					hours. Off timer function will only work when the unit is operating.   
					1. Turn on the air conditioner.   
					Press the Power   
					button on the remote control.   
					2. Set the number of hours you want the air conditioner   
					to run for before it turns off automatically.   
					Press the Timer button on the remote control.   
					Each time you press the button, time will increase   
					in hourly units and can be set up to 24 hours.   
					icon will appear on the display.   
					Operating mode, Temperature and Fan speed can be adjusted before setting Off timer.   
					(See pages 12~14 for instructions.)   
					To deactivate Off timer   
					1. Press the Timer button on the remote control   
					until you see   
					on the display.   
					Timer will be off and the   
					momentarily.   
					icon will disappear   
					The display will then show its earlier temperature and   
					the icons.   
					operating _17   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				operating your air conditioner   
					ADVANCED FUNCTIONS   
					Good Sleep mode   
					This function will be helpful to enjoy your sleep. In Good Sleep mode,the air conditioner will run   
					for 8 hours at the temperature you set before turning off.   
					1. Turn on the air conditioner.   
					Press the Power   
					button on the remote control.   
					2. Set the Good Sleep mode on.   
					Press the Good Sleep button on the remote control.   
					The air conditioner will turn to Cool mode and it will   
					turn off automatically in 8 hours.   
					will appear on the display,then the remaining hours   
					will appear.   
					Operating mode, Temperature and Fan speed can be adjusted before setting Good Sleep   
					mode. (See pages 12~14 for instructions.)   
					Temperature changes in Good Sleep mode   
					Each time you press a button, the unit beeps.   
					The   
					indicator and " " will be displayed.   
					The remaining time is displayed and decreased by 1 hour automatically to indicate the   
					remaining time.   
					If Good Sleep mode is selected after switching on the unit ,the air conditioner will run in Cool   
					mode.During this period, the temperature displayed is one you set for Cool mode. If the Good   
					Sleep mode is selected before switching on the unit,the air conditioner starts running in Cool   
					mode and the temperature is set to 26 °C.   
					The fan will run in low mode,and the speed can be adjusted   
					. 
					To deactivate the Good Sleep mode   
					1. Press the Good Sleep button on the remote control;   
					Good Sleep mode will be cancelled and the unit   
					will operate in Cool mode.   
					• Good Sleep mode is only available in Cool mode.   
					• Air flow can also be adjusted manually. (See page 15 for instructions.)   
					18_ operating   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				operating your air conditioner   
					ADVANCED FUNCTIONS   
					Energy Saving mode   
					If you wish to save energy when using your Air Conditioner,select the Energy Saving mode.   
					1. Turn on the air conditioner.   
					Press the Power   
					button on the remote control.   
					2. Set the Energy Saving mode on.   
					Press the E. Saver button on the remote control.   
					The air conditioner will turn off automatically .   
					E. Saver will appear on the display,then the   
					remaining hours will appear.   
					E.Saver Mode can only be Selected in Cool or Fan mode. when you select E.Saver and the   
					unit running in Cool mode, the temperature and fan speed can be adjusted.If you select   
					E.Saver when the unit is running in Fan mode, the fan speed can be adjusted. (See pages   
					12~14 for instructions.)   
					Energy Saving mode   
					The fan and compressor cycle on and off together.   
					the fan will continue to run for a short time after the   
					compressor cycles off.   
					To deactivate Energy Saving mode   
					Press the E.Saver button on the remote control;   
					E.Saver mode will be cancelled and the unit will   
					return to the mode you previously selecting(Cool or Fan m 
					• Air flow can also be adjusted manually. (See page 15 for instructions.)   
					operating _19   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				cleaning and maintaining your   
					air conditioner   
					Keeping your air conditioner clean improves its performance, wards off unnecessary repairs, and lengthens   
					its life.   
					CLEANING THE EXTERIOR   
					1. Wipe the surface of the appliance with a slightly wet or   
					dry cloth when needed.   
					Do not use Benzene, Thinner or Bleach.   
					They may damage the surface of the unit and can create   
					CAUTION   
					a risk of fire.   
					CLEANING THE AIR FILTER   
					1. Open the front grille and pull out the air filter inserted at the back of the front grille.   
					2. Vacuum the air filter completely.   
					3. Push the air filter back into place.   
					• For best conditions, repeat every two weeks.   
					• If the air filter dries in a confined (or humid) area, odors may generate. If this occurs,   
					re-clean and dry in a well-ventilated area.   
					MAINTAINING THE AIR CONDITIONER   
					If the air conditioner will not be used for an extended period of time, dry it thoroughly and disconnect from the wall.   
					There may be internal damage if moisture is left in its components.   
					1. Before storing the appliance, operate the air conditioner in Fan mode for three to four hours to   
					dry the air conditioner completely.   
					2. Upon removing from storage, dry the inner components of the air conditioner again by   
					running in Fan mode for three to four hours. This helps remove odors which may have   
					generated from dampness.   
					20_ cleaning and maintaining   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				appendix   
					TROUBLESHOOTING   
					Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary   
					expense of a service call.   
					PROBLEM   
					SOLUTION   
					The air conditioner   
					does not start operating   
					immediately after it has   
					been turned on.   
					• Because of the protective mechanism, the appliance does not start   
					operating immediately to keep the unit from overloading.   
					The air conditioner will start in 3 minutes.   
					The air conditioner does • Check that the power plug is properly connected. Insert the power plug   
					not work at all.   
					into the wall socket correctly.   
					• Check if the circuit breaker is switched off.   
					• Check if there is a power failure.   
					• Check your fuse. Make sure it is not blown out.   
					The temperature does   
					not change.   
					• Check if your air conditioner to make sure it is not operating in Fan mode.   
					The cool(warm) air does   
					not come out of the air   
					conditioner.   
					• Check if the set temperature is higher (lower) than the current   
					temperature. Press the Temp button on the remote control or Temp.   
					button on the control panel to change the set temperature.   
					Press  or  to increase or decrease the temperature.   
					• Check if the air filter is blocked by dirt. Clean the air filter every two weeks.   
					• Check if the air conditioner has just been turned on. If so wait 3 minutes.   
					• Check if the appliance is running in a smoky area or if there is a smell   
					entering from outside. Operate the air conditioner in Fan mode or open   
					the windows to air out the room.   
					Odors permeate the   
					room during operation.   
					The air conditioner   
					makes a bubbling sound.   
					• A bubbling sound may be heard when the refrigerant is circulating through   
					the compressor. This is normal operation.   
					The air conditioner   
					vibrates excessively   
					or makes a lot of noise   
					during operation.   
					• Check if there is a gap between the air conditioner and the wall. Insulate   
					the crack securely.   
					Water is dripping from   
					the air flow blades.   
					• Check if the air conditioner has been cooling for an extended period of   
					time with the air flow blades pointed downwards. Condensation may   
					generate due to the difference in temperature. Push the vertical air flow   
					blades upward and run the appliance.   
					Remote control is not   
					working.   
					• Check if your batteries are depleted.   
					• Make sure batteries are correctly installed.   
					• Make sure nothing is blocking the remote control sensor.   
					OPERATION RANGES   
					The table below indicates the temperature and humidity ranges the air conditioner can be operated within.   
					Refer to the table for efficient use.   
					OPERATIONAL TEMPERATURE   
					MODE   
					INDOOR HUMIDITY   
					INDOOR   
					OUTDOOR   
					COOLING   
					Approximately 21˚C~32˚C Approximately 21˚C~43˚C   
					80% or less   
					appendix _21   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				E F DB98-29033A   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 | 
Q See Security Camera QS218 411 User Guide
Quatech Network Router ABDB ET Series User Guide
Radio Shack Answering Machine TAD 795 User Guide
RCA Projection Television P52955 User Guide
Samsung CRT Television TX T2781, TX T2782, TX T2082 User Guide
Samsung MP3 Player MCD MP65 User Guide
Samsung Printer SRP 370G User Guide
Samsung Security Camera SNC B2335P User Guide
Samsung Washer J1053 V S User Guide
Sanyo Heat Pump APR RZP680BAB User Guide