ENFORCER Video Ground Loop Isolator
Installation Manual
Specifications:
®
Bandwidth
Video DC to 8MHz
1.0Vp-p
<0.5dB
0-3dB at 10MHz
____________________________________________________________________________________________________________________
ENFORCER
Maximum Input
____________________________________________________________________________________________________________________
Insertion Loss
_______________________________________________________________________________________________________________________________
VG-1C12AQ
Frequency Response
________________________________________________________________________________________________________________________________
Video Ground Loop Isolator
Isolation Voltage
600VDC (Min)
__________________________________________________________________________________________________________________________
Insulation Resistance
100M Ohm
______________________________________________________________________________________________________________________________
Connector In
Connector Out
BNC Male
BNC Female
_____________________________________________________________________________________________________________________________________
Impedance
75 ohm (BNC to BNC)
_________________________________________________________________________________________________________________________________
Dimensions
23/16" x 17/32" x 1" (55 x 31 x 26 mm)
___________________________________________________________________________________________________________________________
Material
ABS Black
____________________________________________________________________________________________
Temperature
Operating temp. 32°~131° F (0°~55° C)
What it is:
The ENFORCER video ground loop isolator is a passive device that helps to
reduce ground loop interference caused by a difference in ground potential
typically caused by multiple building grounds and differences in ground potential.
Ground loop isolators can be installed in new installations or added to existing
installations.
IMPORTANT: Users and installers of this product are responsible for ensuring this product complies with all
national, state, and local laws and statutes related to monitoring and recording audio and video signals. SECO-LARM will
not be held responsible for the use of this product in violation of any current laws or statutes.
WARNING: Incorrect mounting which leads to exposure to rain or moisture inside the enclosure could cause a
dangerous electric shock, damage the device, and void the warranty. Do not open the case of this device, as there are no
field-serviceable components inside.
Video ground loop isolators should be installed on the camera side of your cable
and can be used with standard BNC coax cable or with video baluns over UTP.
WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used in
normal service for a period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s
obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to
SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or
abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason
SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material
and workmanship. The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to
replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral,
incidental, or consequential personal or property damages of any kind to the purchaser or anyone else.
Features:
O
Built-in surge suppressor.
O
Gold-plated BNC connector improves reliability and product life.
O
Passive operation -- No external power required.
NOTICE: The information and specifications printed in this manual are current at the time of publication. However,
the SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the
right to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.
O
High immunity from interference -- Built-in impedance coupled device and noise
filter. Helps to reduce RF interference, cross talk, picture tearing, and other
picture quality problems.
Copyright © 2007 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole
or in part, without the written permission of SECO-LARM.
O
BNC terminals for easy installation.
®
SECO-LARM® U.S.A., Inc., 16842 Millikan Avenue, Irvine, CA 92606
PITLW2
7
Small size, only 23/16" x 1 /32" x 1" (55 x 31 x 26 mm).
MiVG-1C12AQ.pmd
O
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
Page 4
E-mail: sales seco-larm.com
@
Download from Www.Somanuals.com. All Manuals Search And Download.
|