RuggedSwitch RSG2200
9-Port Modular Managed Gigabit Ethernet Switch
Installation Guide
RuggedCom Inc. I 30 Whitmore Road, Woodbridge, Ontario, Canada L4L 7Z4
Tel: (905) 856-5288 I Fax: (905) 856-1995 I Toll Free: (888) 264-0006
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
1
2
3
Table of Figures ...................................................................................................................... 4
Table of Tables........................................................................................................................ 4
Product Overview.................................................................................................................... 5
3.1
Functional Overview........................................................................................... 5
Feature Highlights............................................................................................... 6
Mounting Flexibility........................................................................................... 8
Ethernet Panel Description ................................................................................. 9
Fiber Optical Transceiver Orientation and Connection............................ 10
Display Panel Description................................................................................. 11
3.2
3.3
3.4
3.4.1
3.5
4
Installation ............................................................................................................................. 13
4.1
Rack Mounting.................................................................................................. 13
Panel and DIN Rail Mounting .......................................................................... 14
Power Supply Wiring and Grounding............................................................... 15
AC Power Supply Wiring Examples ........................................................ 17
DC Power Supply Wiring Examples ........................................................ 18
Dual Power Supplies – DC and AC Inputs............................................... 19
Dielectric Strength (HIPOT) Testing................................................................ 20
Failsafe Alarm Relay Wiring and Specifications.............................................. 21
Console Port Wiring ......................................................................................... 22
Gigabit Ethernet 1000Base-TX Cabling Recommendations............................ 23
Pluggable optics – Installation, removal, and precautions................................ 24
Module Insertion – GBICs and SFPs........................................................ 24
GBIC Module Removal ............................................................................ 25
SFP Module Removal............................................................................... 25
4.2
4.3
4.3.1
4.3.2
4.3.3
4.4
4.5
4.6
4.7
4.8
4.8.1
4.8.2
4.8.3
5
Technical Specifications........................................................................................................ 26
5.1
Power Supply Specifications ............................................................................ 26
Failsafe Relay Specifications............................................................................ 26
Networking Standards Supported ..................................................................... 26
Twisted-Pair Port Specifications....................................................................... 27
Fiber Optical Specifications.............................................................................. 28
Gigabit Ethernet (1000Mbps) Modules .................................................... 28
Type Test Specifications................................................................................... 30
Operating Environment..................................................................................... 31
Mechanical Specifications ................................................................................ 32
5.2
5.3
5.4
5.5
5.5.1
5.6
5.7
5.8
6
7
Agency Approvals ................................................................................................................. 33
Warranty................................................................................................................................ 33
3
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
1 Table of Figures
Figure 1: RSG2000 Rack mount chassis orientation options – Front and rear mount...................... 8
Figure 2: Ethernet, LED Status, and Power Panels ........................................................................ 9
Figure 3: Ethernet panel LED description........................................................................................ 9
Figure 4: 1000LX SFP (mini-GBIC) Module and LC connector..................................................... 10
Figure 5: 1000LX GBIC connector ................................................................................................ 10
Figure 6: 1000LX LC connector .................................................................................................... 10
Figure 7: 1000LX SC connector.................................................................................................... 10
Figure 8: 1000LX ST connector .................................................................................................... 11
Figure 9: RSG2200 LED Display Panel ........................................................................................ 11
Figure 10: RSG2000 Family 19” Rack Mount Adapters ................................................................ 13
Figure 11: Rack mount adapter mounting location........................................................................ 13
Figure 12: RSG2200 PANEL/DIN RAIL mounting diagram with.................................................... 14
Figure 13: RSG2000 Series Philips Screw Terminal Block ............................................................ 15
Figure 14: RSG2000 Series Phoenix Plug Terminal Block............................................................. 15
Figure 15: AC Power supply wiring examples................................................................................ 17
Figure 16: DC Power supply wiring examples............................................................................... 18
Figure 17: DC And AC power supply wiring examples.................................................................. 19
Figure 18: Dielectric Strength (HIPOT) Testing.............................................................................. 20
Figure 19: Failsafe Alarm Relay Wiring.......................................................................................... 21
Figure 20: Console port location on display board ........................................................................ 22
Figure 21: RSG2200 Console cable.............................................................................................. 22
Figure 22: SFP Orientation for top row and bottom row ports ....................................................... 24
Figure 23: Locking latch location on GBIC optical modules .......................................................... 25
Figure 24: SFP Bail Latch location................................................................................................ 25
Figure 25: SFP Removal............................................................................................................... 25
Figure 26: RSG2200 Series mechanical dimensions.................................................................... 32
2 Table of Tables
Table 1: LED Display – Device status LED behavior definition ..................................................... 12
Table 2: Port Status behavior definition ........................................................................................ 12
Table 3: RSG2200 Power terminal block connection description................................................... 16
Table 4: RS232 over RJ45 console cable pin-out ......................................................................... 22
Table 5: Cabling categories and 1000BaseTx compliance defined............................................... 23
Table 6: Gigabit port optical specifications.................................................................................... 28
4
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
3 Product Overview
3.1 Functional Overview
The RuggedSwitch™ RSG2200 is an industrially hardened, fully managed, modular, Ethernet
switch specifically designed to operate reliably in electrically harsh and climatically demanding
utility substation and industrial environments. The RSG2200’s superior ruggedized hardware
design coupled with the RuggedSwitch™ Operating System (ROS) provides improved system
reliability and advanced networking features making it ideally suited for creating Ethernet networks
for mission-critical, real-time, control applications.
The RSG2200’s modular flexibility offers 1000BaseX fiber and 10/100/1000BaseTX copper port
combinations. Optional front or rear mount connectors make theRSG2200 highly versatile for any
application and can support multiple fiber connectors (SFP, GBIC, LC, SC) without loss of port
density. The RSG2200 is packaged in a rugged galvanized steel enclosure with industrial grade
DIN, panel, or 19" rack mount mounting options.
5
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
3.2 Feature Highlights
Ethernet Ports
•
•
•
•
•
•
•
•
•
9-Gigabit Ethernet ports supporting copper and fiber media
2 port modules for tremendous flexibility
Multimode and singlemode fiber support
Bi - directional singlestrand fiber support
Full compliance with IEEE: 802.3, 802.3u & 802.3z
Non-blocking, store and forward switching
Full duplex operation and flow control (IEEE 802.3x)
Industry standard fiber optical connectors: LC, SC, SFP, GBIC
Long haul optics allow Gigabit distances up to 70km
RuggedRated™ for Reliability in Harsh Environments
•
•
•
•
•
•
•
•
Meets IEEE 1613 (electric utility substations)
Exceeds IEC 61850-3 (electric utility substations)
Exceeds IEEE 61800-3 (variable speed drive systems)
Exceeds IEC 61000-6-2 (generic industrial environment)
Exceeds NEMA TS-2 (traffic control equipment)
-40 to +85°C operating temperature (no fans)
Conformal coated printed circuit boards (optional)
18 AWG galvanized steel enclosure
Universal Power Supply Options
•
•
•
•
•
Fully integrated, dual-redundant (optional) power supplies
Universal high-voltage range: 88-300VDC or 85-264VAC
Popular low voltage DC ranges: 12, 24 or 48 VDC
Terminal blocks for reliable maintenance free connections
CSA/UL 60950 safety approved to +85°C
Simple Plug and Play Operation
•
•
•
•
Automatic learning of up to 8192 MAC addresses
Auto-negotiation on all 10/100/1000BaseTX ports
Auto-MDI/MDIX (crossover) on all 10/100BaseTX ports
LED indicators for link, activity and speed
6
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
Rugged Operating System (ROS™) Advanced Network Management
•
•
•
•
•
•
•
•
•
•
Enhanced Rapid Spanning Tree (eRSTP™)
Quality of Service (802.1p) for real-time traffic
Port rate limiting: 128kbps - 8Mbps
VLAN (802.1q) with double tagging
IGMP Snooping for multicast filtering
Port configuration, status, statistics, mirroring, security
Loss of link management on fiber ports
Web-based, Telnet, CLI management interfaces
SNMP v2 and RMON
Rich set of diagnostics with logging and alarms
7
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
3.3 Mounting Flexibility
The RSG2000 series of products have been designed with maximum mounting and display
flexibility. Customers can order an RSG2000 series switch that can be mounted in a standard 19”
rack, 1” DIN Rail, or directly onto a panel. For rack mount installations, the RSG2000 series can
be ordered with connectors on the front of the unit, or can located on the rear of the chassis to
allow for all data and power cabling to be installed and connected at the rear of the rack. See
Figure 1 for rack mount orientation examples.
Figure 1: RSG2000 Rack mount chassis orientation options – Front and rear mount.
8
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
Power Terminal Block
I/O Ports
LED Display Panel
Ethernet Port
Ethernet Ports
Ethernet Ports
Figure 2: Ethernet, LED Status, and Power Panels
3.4 Ethernet Panel Description
Each Ethernet module is equipped with two LEDs that indicate link/activity status information. The
LED will be solid for ports with link, and will blink for activity. The diagram in Figure 3 highlights the
port and the associated link/activity LED.
Figure 3: Ethernet panel LED description
9
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
3.4.1 Fiber Optical Transceiver Orientation and Connection
Depending on the order code of the product, the RSG2000 series products can be equipped with
several different types of fiber optic ports. The Transmit (TX) and Receive (RX) connections of
each port must be properly connected and matched for proper link and operation. Modules
populated on the top row of the device typically have locking mechanisms or tabs towards the top
of the unit. Modules located on the bottom row of the device have locking mechanisms or tabs
towards the bottom of the device.
The drawings in the following figures show each fiber optical connector style with a side and top
view to allow the user to identify the proper cable connection orientation. If modules are populated
on the bottom row of the device, the transceiver orientation will be reversed (ie RX and TX will be
reversed).
Figure 4: 1000LX SFP (mini-GBIC) Module and
Figure 5: 1000LX GBIC connector
LC connector
Figure 7: 1000LX SC connector
Figure 6: 1000LX LC connector
10
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 8: 1000LX ST connector
3.5 Display Panel Description
The RSG2000 series products are equipped with a versatile display panel, shown in Figure 9,
which is designed to provide quick status information for each port, as well as the entire device to
allow for simple diagnostics and troubleshooting. It features:
•
•
•
RS232 console port for ‘out of band’ console access and configuration
Power supply and Alarm status indicators
Convenient port status indicators conveying Link-Activity, Duplex, or Speed via push-
button control.
•
System reset via push-button if held for 5 seconds
Figure 9: RSG2200 LED Display Panel
11
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
Device status LEDs exist to provide a quick visual indicator to operators for operational status of
the unit. Table 1 defines the possible LED colours and the corresponding description.
LED
Colour
Green
Description
Power supply operating normal
PS1 / PS2
Red
Off
Red
Power supply failure
No power supply installed
Alarm exist – login to web management interface to
determine alarm code
Alarm
Off
No alarms exist
Table 1: LED Display – Device status LED behavior definition
The port-based LEDs can be cycled between three display modes: Status, Duplex, and Speed.
Pushing the mode button causes the display mode to be cycled.
Mode
Colour
Description
Green (Solid)
Link
Status
Green (Blinking)
Off
Activity
No link
Green (Solid)
Orange (Solid)
Off
Green (Blinking)
Green (Solid)
Orange (Solid)
Off
Full-Duplex operation
Half-Duplex operation
No link
1000Mb/s
100Mb/s
Duplex
Speed
10Mb/s
No link
Table 2 defines the possible port LED colours and the corresponding description.
Mode
Colour
Green (Solid)
Description
Link
Status
Green (Blinking)
Off
Activity
No link
Green (Solid)
Orange (Solid)
Off
Green (Blinking)
Green (Solid)
Orange (Solid)
Off
Full-Duplex operation
Half-Duplex operation
No link
1000Mb/s
100Mb/s
Duplex
Speed
10Mb/s
No link
Table 2: Port Status behavior definition
12
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
4 Installation
4.1 Rack Mounting
Figure 10: RSG2000 Family 19” Rack Mount Adapters
Figure 11: Rack mount adapter mounting location
The RSG2000 family of products can be rack mounted using the included rack mount adapter
assemblies shown in Figure 10. Secure the rack mount adapter to the front side of the chassis
using the included black PAN head Philips screws in the positions shown in Figure 12. The entire
chassis can then be mounted to a standard 19” rack. An additional two rack mount adapters are
included to optionally secure the rear of the chassis in high-vibration, or seismically active
locations.
Note: Since heat within the RS2000 is channeled to the enclosure, it is recommended that 1 rack-
unit of space (1.75”) be kept unpopulated and free of equipment above each RS2000 series
product to allow for a small amount of convectional airflow. Although forced airflow is not
necessary, any increase in airflow will result in a reduction of ambient temperature that will improve
long-term reliability of all equipment mounted within the rack space.
13
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
4.2 Panel and DIN Rail Mounting
The RSG2200 series products can be ordered as a Panel/DIN mount chassis. Both options
involve the use of the panel/DIN adapters to be mounted on each side of the chassis enclosure.
The adapter allows for the chassis to be mounted on the standard 1” DIN rail using the grooves in
the adapter, secured using the included Philips screw. See Figure 12 for a PANEL/DIN mount
diagram.
Figure 12: RSG2200 PANEL/DIN RAIL mounting diagram with
14
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
4.3 Power Supply Wiring and Grounding
Philips Screw Terminal with Cover
Philips Screw Terminal without Cover
Safety Cover
Terminal
Chassis Ground
Connection
Surge / Chassis
Ground Jumper
Safety Cover
Screws
Figure 13: RSG2000 Series Philips Screw Terminal Block
Phoenix Plug Terminal with Cover
Phoenix Plug Terminal without Cover
Safety Cover
Screws
Surge / Chassis
Ground Jumper
Safety Cover
Terminal
Chassis Ground
Connection
Figure 14: RSG2000 Series Phoenix Plug Terminal Block
The RSG2200 family supports dual redundant power supplies – “Power Supply 1 (PS1)” and
“Power Supply 2 (PS2)”. The connections for PS1, PS2 and the fail-safe relay are located on the
terminal block as shown in Figure 13 and Figure 14.
The RSG2200 family can be equipped with either a Philips Screw Terminal Block or a Phoenix
Plug Terminal Block. The Philips Screw Terminal Block has Philips screws with a compression
plate allowing either bare wire connections or crimped terminal lugs. We recommend the use of #6
size ring lugs to ensure secure, reliable connections under severe shock or vibration. Both terminal
blocks have a safety cover which must be removed via two Phillips screws before connecting any
wires. The safety cover must be re-attached after wiring to ensure personnel safety. Refer to Table
3 below for a description of each terminal as well as sections 4.3.1 through 4.3.3 for wiring
examples.
15
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
Terminal #
Description
PS1 Live / +
Usage
PS1 Live / + is connected to the positive (+) terminal if the
power source is DC or to the (Live) terminal if the power
source is AC.
1
PS1 Surge Ground is connected to the Chassis Ground via
a jumper on the terminal block. Surge Ground is used as the
ground conductor for all surge and transient suppression
circuitry. NOTE: Surge Ground must be disconnected
from Chassis Ground during HIPOT (dielectric strength)
testing.
2
PS1 Surge Ground
PS1 Neutral / - is connected to the negative (-) terminal if
the power source is DC or to the (Neutral) terminal if the
power source is AC.
Chassis Ground is connected to the Safety Ground
terminal for AC inputs or the equipment ground bus for DC
inputs. Chassis ground connects to both power supply surge
grounds via a removable jumper.
PS2 Live / + is connected to the positive (+) terminal if the
power source is DC or to the (Live) terminal if the power
source is AC.
3
4
5
PS1 Neutral / -
Chassis Ground
PS2 Live / +
PS2 Surge Ground is connected to the Chassis Ground via
a jumper on the terminal block. Surge Ground is used as the
ground conductor for all surge and transient suppression
circuitry. NOTE: Surge Ground must be disconnected
from Chassis Ground during HIPOT (dielectric strength)
testing.
PS2 Neutral / - is connected to the negative (-) terminal if
the power source is DC or to the (Neutral) terminal if the
power source is AC.
6
7
PS2 Surge Ground
PS2 Neutral / -
8
9
Relay NO Contact
Relay Common
Normally open, failsafe relay contact.
Failsafe relay common contact.
10
Relay NC Contact
Normally closed, failsafe relay contact.
Table 3: RSG2200 Power terminal block connection description
16
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
4.3.1 AC Power Supply Wiring Examples
Figure 15: AC Power supply wiring examples
Notes:
1. 100-240VAC rated equipment: A 250VAC appropriately rated circuit breaker must be
installed within 3m of unit.
2. Equipment must be installed according to the applicable country wiring codes.
3. When equipped with two HI voltage power supplies, independent AC sources can be
used to power the product for greater redundancy.
17
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
4.3.2 DC Power Supply Wiring Examples
Figure 16: DC Power supply wiring examples
Notes:
1. 88-300VDC rated equipment: A 300VDC appropriately rated circuit breaker must
be installed within 3m of unit.
2. A circuit breaker is not required for 12, 24 or 48 VDC rated power supplies.
3. For dual DC power supplies, Separate circuit breakers must be installed and
separately identified.
4. Equipment must be installed according to the applicable country wiring codes.
18
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
4.3.3 Dual Power Supplies – DC and AC Inputs
Figure 17: DC And AC power supply wiring examples
Notes:
1. 88-300VDC rated equipment: A 300VDC appropriately rated circuit breaker must
be installed within 3m of unit.
2. 100-240VAC rated equipment: A 250VAC appropriately rated circuit breaker must
be installed within 3m of unit.
3. A circuit breaker is not required for 48 or 24VDC rated power supplies.
4. Separate circuit breakers must be installed and separately identified.
5. Equipment must be installed according to the applicable country wiring codes.
19
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
4.4 Dielectric Strength (HIPOT) Testing
For dielectric strength (HIPOT) testing in the field, users must remove the metal jumper located on
terminal 2, 4, and 6 of the power supply terminal block. This metal jumper connects transient
suppression circuitry to chassis ground and must be removed in order to avoid damage to transient
suppression circuitry during HIPOT testing. Figure 18 shows the proper HIPOT test connections
and should be followed to avoid damage to the device.
Figure 18: Dielectric Strength (HIPOT) Testing
20
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
4.5 Failsafe Alarm Relay Wiring and Specifications
The “Failsafe” output relay is provided to signal critical error conditions that may occur on the
RSG2200 series products. The contacts are energized upon power up of the unit and remain
energized until a critical error occurs. The proper relay connections are shown in Figure 19. One
common application for this output is to signal an alarm if a power failure or removal of control
power occurs.
Figure 19: Failsafe Alarm Relay Wiring
21
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
4.6 Console Port Wiring
A RS232 console port for configuration and management of the device is located on the LED
display module shown in Figure 20. This port is intended to be a temporary connection during
initial configuration or troubleshooting and allows for direct access to the serial-based management
console. The connection is made using the DB9-Female to RJ45 console cable included in the
device packaging shown in Figure 21. Console connection settings are: 57600 baud, no parity
bits, 8 data bits, and 1 stop bit.
Figure 20: Console port location on display board
Figure 21: RSG2200 Console cable
For user reference, the console cable pin-out is show in Table 5.
RuggedCom RS232 over RJ45 pin-out specification
Signal Name (PC is DTE)
DCD – Carrier detect
RxD – Receive data (to DTE)
TxD – Transmit data (from DTE)
DTR – Data terminal ready
Signal GND
DB9- Female
RJ45 Male
1
2
3
4
5
6
7
8
9
2
5
6
3
4
1*
8
7
DSR – Data set ready
RTS – Ready to send
CTS – Clear to send
RI – Ring Indicator
1*
Table 4: RS232 over RJ45 console cable pin-out
After initial configuration, the RuggedRouter device can be configured via a number of new
mechanisms such as Telnet, and the built-in web server. Consult the RuggedRouter ROS User
Guide for further details.
NOTE: This port is not intended to be a permanent connection and the cable shall be less than 2m
(6.5 ft) in length.
22
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
4.7 Gigabit Ethernet 1000Base-TX Cabling Recommendations
The IEEE 802.3ab Gigabit Ethernet standard defines 1000 Mbit/s Ethernet communications over
distances of up to 100 meters using 4 pairs of category 5 (or higher) balanced unshielded twisted-
pair cabling. For wiring guidelines, system designers and integrators should refer to the
Telecommunications Industry Association (TIA) TIA/EIA-568-A wiring standard that characterizes
minimum cabling performance specifications required for proper Gigabit Ethernet operation. To
ensure reliable, error-free data communications, new and pre-existing communication paths should
be verified for TIA/EIA-568-A compliance. Table 5 summarizes cabling standards available today
Cabling
Category
< 5
1000BaseTx
Compliant
No
Required action
New wire infrastructure required
5
Yes
Verify TIA/EIA-568-A compliance
No action required. New installations should be designed with
Category 5e components or higher
5e
Yes
6
> 6
Yes
Yes
No action required
Connector and cabling standards to be determined.
Table 5: Cabling categories and 1000BaseTx compliance defined.
In general the following recommendations should be followed for copper data cabling in high
electrical noise environments:
•
•
Data cable lengths should be as short as possible, ideally limited to 3m (10ft) in length.
Copper data cables should not be used for inter-building communications.
Power and data cables should not be run in parallel for long distances, and ideally should be
installed in separate conduits. Power and data cables should intersect at 90° angles when
necessary to reduce inductive coupling.
•
Shielded/screened cabling can optionally be used. The cable shield should be grounded at
one single point to avoid the generation of ground loops.
NOTE: RuggedCom does not recommend the use of copper cabling of any length for critical real-
time substation automation applications. However, transient suppression circuitry is present on all
copper ports to protect against damage from electrical transients and to ensure IEC 61850-3 and
IEEE 1613 Class 1 conformance. This means that during the transient event communications
errors or interruptions may occur but recovery is automatic. RuggedCom also does not
recommended to use these ports to interface to field devices across distances which could produce
high levels of ground potential rise, (i.e. greater than 2500V) during line to ground fault conditions.
23
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
4.8 Pluggable optics – Installation, removal, and precautions
The RSG2000 series of products can be ordered with pluggable optic form factors such as SFP
(Small Form-factor Pluggable) or GBIC (Gigabit Interface Converter) modules. These modules can
be safely inserted and removed while the chassis is powered and operating – this feature is also
known as “hot-swappable”. When inserting or removing optics there are several precautions that
should be taken. They include:
•
Ensuring that dust caps are mounted on SFP cages at all times unless a user is in the process
of inserting or removing an SFP module. The dust caps will prevent the accumulation of
residue or particles that may inhibit proper operation.
•
Ensuring that the user has properly discharged any possible electrostatic build-up and
electrostatic discharges (ESD). This can be accomplished by properly user ‘grounding’ via an
ESD wrist strap, or by touching earth or chassis ground before performing installation or
removal of optics. ESD can damage or shorten the life of optical modules when not plugged
into a chassis.
•
SFP and GBIC optical modules should always be stored in an ESD safe bag or other suitable
ESD safe environment, free from moisture and stored at proper storage temperature (–40 to
+85°C).
•
•
Disconnect all cables from SFP or GBIC module before insertion or removal of module.
Only RuggedCom Inc. certified optics should be used on RuggedCom products. Damage can
occur to optics and product if compatibility and reliability have not been properly assessed.
4.8.1 Module Insertion – GBICs and SFPs
To insert GBICs or SFPs, special attention should be taken into the proper module orientation.
Refer to Figure 22 for proper module orientation, as ports on the upper row of the product require
optics to be inserted topside-up, and ports on the lower row of the product require modules to be
inserted topside-down. GBICs should be inserted with module dust cover in place. SFPs should
be inserted with dust cover in place, and the bail-latch in the locked position. Module should gently
slide into port and should lock in place when module is fully inserted. To protect optics, dust
covers should always be installed when cables are not connected.
Figure 22: SFP Orientation for top row and bottom row ports
24
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
4.8.2 GBIC Module Removal
GBIC Modules have two locking latches on either side of the module shown in Figure 23. To
remove GBIC module, disconnect any cable and replace with dust cover to protect the optics.
User should depress both latches simultaneously and gently pull the module from the chassis. The
module should be immediately stored in an ESD-safe environment.
Figure 23: Locking latch location on GBIC optical modules
4.8.3 SFP Module Removal
SFP Modules are removed using the metal bail latch located on the top of the module shown in
Figure 24. To remove the SFP module, disconnect any cable and replace with dust cover to
protect the optics. User should grasp bail latch and gently pull outwards to unlock and remove the
SFP module. Removal of the SFP module is shown further in Figure 25. The module should be
immediately stored in an ESD-safe environment.
Figure 25: SFP Removal
Figure 24: SFP Bail Latch location
25
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
5 Technical Specifications
5.1 Power Supply Specifications
Power Supply Type
Input Range
Fuse
Rating
Max. Power
Consumption3
Min
Max
12 – 24 VDC
24 VDC
10 VDC
18 VDC
36 VDC
88 VDC 300 VDC
85 VAC 265 VAC
36 VDC
36 VDC
59 VDC
6.3A(F) 2
5A(F) 2
2A(T) 2
22W
48 VDC
HI (125/250 VDC) 1
2A(T) 1,2
HI (110/230 VAC) 1
NOTES:
1. This is the same power supply for both AC and DC.
2. (F) Denotes fast-acting fuse, (T) denotes time-delay fuse
3. Power consumption varies based on configuration. 10/100Base-TX ports consume roughly
1W less than fiber optic ports
4. For continued protection against risk of fire, replace only with same type and rating of fuse.
5.2 Failsafe Relay Specifications
Parameter
Value (Resistive Load)
Max Switching Voltage
240VAC, 125VDC
Rated Switching Current 2A @ 240VAC
0.15A @ 125VDC, 2A @ 30VDC
Max Switching Capacity 150W, 500VA
5.3 Networking Standards Supported
10Mbps
Ports
100Mbps
Ports
1000Mbps
Ports
Parameter
Notes
IEEE 802.3
IEEE 802.3u
IEEE 802.3z
IEEE 802.3ab
IEEE 802.3x
IEEE 802.1D
IEEE 802.1Q
IEEE 802.1p
10BaseT / 10BaseFL
100BaseTX / 100BaseFX
1000BaseSX/LX
1000BaseTx
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Full Duplex Operation
MAC Bridges
VLAN (Virtual LAN)
Priority Levels
ꢀ
ꢀ
26
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
5.4 Twisted-Pair Port Specifications
Parameter
Specification
Notes
Speed
Duplex
Cable-Type
Wiring Standard
Max Distance
Connector
10/100 Mbps
FDX / HDX
> Category 5
TIA/EIA T568A/B
100m
Auto-negotiating
Auto-negotiating
Shielded/Unshielded
Auto-Crossover, Auto-polarity
RJ45
Isolation
1.5kV
RMS 1-minute
27
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
5.5 Fiber Optical Specifications
The following sections detail fiber optical specifications on ports that can be ordered with the
RSG2200 series Ethernet switch. The user determines the type of optics at time of ordering, and
can determine the modules installed on a particular unit by reading the factory data file via the
RuggedSwitch ROSTM user interface. The following sections detail specifications of fiber optic
modules in Gigabit Ethernet (1000Mbps).
5.5.1 Gigabit Ethernet (1000Mbps) Modules
For maximum flexibility RuggedCom Inc. offers a number of different transceiver choices for
Gigabit fiber optical communications. Table 6 details fiber optic specifications based on the 2-port
modules or pluggable transceivers selected at time of ordering.
Cable
Type2
(µm)
Power
Budget
(dB)
Tx Pwr
(dBm) 3
(Min/Max)
Rx
Rx
Typical
Optics
Order Code
Mode /
Connector
Tx
(nm)
λ
Sensitivity Saturation Distance
(dBm) 3
(dBm) 3
(km)1
12-11-0036
12-11-0027
12-11-0028
12-11-0025
12-11-0026
MM / LC
SM / LC
850
50/125
-9.5 / -4
-9.5 / -3
-5 / 0
-10 / -3
-5 / 0
-20
-22
-22
-22
-20
0
0.5
10
25
10
25
13
-3
-3
-3
-3
18.5
19.5
15.5
17.5
1310
9/125
SM / SC
SFP Pluggable Optics
SFP
MM / LC
25-10-0111
850
50/125
-8.5 / -4
-22
-3
0.5
15.5
25-10-0100
25-10-0101
25-10-01085
25-10-01094
-9 / -3
-7 / -3
-5 / 0
0 / 5
-24
-26
-26
-26
0
-3
-3
0
10
25
40
70
19
21
23
28
1310
15504
1310
14904
SFP
SM / LC
9/125
SFP
SM / SC
SFP
Simplex
9/125
Simplex
9/125
25-10-0202
25-10-02034
-9 / -3
-9 / -3
-22
-22
-3
-3
10
10
16
16
SM / SC
GBIC Pluggable Optics
25-10-0102
25-10-0103
25-10-01054
-9 / -3
-3 / 2
0 / 5
-21
-23
-23
-3
-3
-3
10
40
70
15
23
25.5
1310
GBIC
SM / SC
9/125
15504
Table 6: Gigabit port optical specifications
Notes:
1. Maximum segment length is greatly dependent on factors such as fiber quality, and
number of patches and splices. Please consult RuggedCom sales associates when
determining maximum segment distances.
28
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
2. All cabling is duplex type unless otherwise specified.
3. All optical power numbers are listed as dBm averages.
4. These transceivers utilize a distributed feedback (DFB) type laser and are rated for -20°C
to +85°C operation only.
5. The 25-10-0108 SFP module is obsolete, and has been replaced with the 70km
25-10-0109 SFP module.
29
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
5.6 Type Test Specifications
Electrical Safety
Levels
Comments
ANSI/IEEE C37.90 (1989)
IEC 60255-5 (Section 6)
IEC 60255-5 (Section 8)
IEC 60255-5 (Section 6
Dielectric Withstand
2 kV rms for 1 minute
High Voltage Impulse
Insulation Resistance
5 kV peak
500 VDC for 1 minute
Electrical Environment
High Frequency Disturbance
(Oscillatory)
Levels
Comments
ANSI/IEEE C37.90.1
IEC 60255-22-1
IEC 61000-4-5
(Level 4)
2.5 kV @ 1MHz for 2s
IEC Surge
4 kV / 2 kV
2 kV / 1 kV
IEC 61000-4-4
(Level 4)
IEC Fast Transient
ANSI/IEEE Fast Transient
IEC Radiated RFI Immunity
ANSI/IEEE Radiated RFI
Immunity
4 kV
10 V/m
ANSI/IEEE C37.90.1
IEC 61000-4-3
20 V/m
ANSI/IEEE C37.90.2
ESD
15 kV (air discharge)
8 kV (contact)
IEC 61000-4-2
(Level 4)
(Electrostatic Discharge)
Atmospheric Environment
Levels
Comments
IEC 60068-2-1
Test Ad: 16 hrs @ -40°C
IEC 60068-2-2
Temperature (Dry Cold)
-40°C
Temperature (Dry Heat)
Humidity
85°C
Test Bd: 16 hrs @ 85°C
IEC 60068-2-30
Test Db: 6 cycles, 55°C, 95% Humidity
95%
non-condensing
30
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
5.7 Operating Environment
Parameter
Range
Comments
Ambient Temperature as
measured from a 30cm
radius surrounding the
center of the RS1600
enclosure.
Ambient Operating
Temperature
-40 to 85°C
Ambient Relative Humidity
Ambient Storage
5% to 95%
Non-condensing
-40 to 85°C
Temperature
31
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
5.8 Mechanical Specifications
Parameter
Dimensions
Value
Comments
(Length x Width x Height)
with mounting brackets
installed
18.29 x 12.14 x 1.75 inches
(464,57) x (308,356) x (44,45) mm
Weight
10 lb (4.5 Kg)
Enclosure
18awg galvanized steel
Figure 26: RSG2200 Series mechanical dimensions
32
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
6 Agency Approvals
Agency
CSA
CE
FCC
CISPR
FDA/CDRH
IEC/EN
Standards
CSA C22.2 No. 60950, UL 60950
Comments
Approved
Approved
Approved
Approved
Compliant
Compliant
EN 60950, EN 61000-6-2
FCC Part 15, Class A
EN55022, Class A
21 CFR Chapter 1, Subchapter J
EN60825-1:1994 + A11:1996 + A2:2001
7 Warranty
RuggedCom warrants this product for a period of five (5) years from date of purchase. For
Should this product require warranty or service contact the factory at:
RuggedCom Inc.
30 Whitmore Road
Woodbridge, Ontario
Canada L4L 7Z4
Phone: (905) 856-5288
Fax: (905) 856-1995
33
2008 RuggedCom Inc. All rights reserved
Rev105
Download from Www.Somanuals.com. All Manuals Search And Download.
|