RMZ-955
MULTI-ROOM
SYSTEM
MULTI-ZONE CUSTOM CONTROLLER RMZ-955
DIGITALLY CONTROLLED AUDIO PROCESSING
POWER
ZONE A
ACTIVE CODE
ZONE B
ZONE C
ZONE D
ACTIVE CODE
ACTIVE CODE
ACTIVE CODE
I.R. TRANSMITTER
Installation & Operation
Manual
Operating
Instructions
begin on Page 23
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
RKP-901 Keypad _____________________________________ 17
Getting Started
4
RKP-901 Mounting
RKP-901 Data Connections
17
17
Controlling the Remote Zones
System Flexibility
System Highlights
4
4
4
Zone Connection Strategies __________________________ 18
Component Description_______________________________ 4
RMZ-955 Controller/Amplifier
System Planning _____________________________________ 4
Installation: Multi-controller Systems
18
4
AC Power ___________________________________________ 20
RR-952 IR Remote Control
RSM-901 Sensor/Display
RKP-901 Keypad
RSM-901/RKP-901 Combination
Placement
Connections:
IR Flood Emitter
IR Repeater Jacks
5
5
5
5
6
6
6
6
AC Connections
AC Link
Manual AC Override
20
20
20
Source Connections _________________________________ 20
IR Connections ______________________________________ 21
For 2 RMZ-955s (5 to 8 zones):
For 3 RMZ-955s (9-12 zones):
For 4 RMZ-955s (13-16 zones):
Exception: Multiple IR Flood Emitters
Paging Connections
21
21
22
22
22
System Wiring Considerations ________________________ 6
Data Cable and Connectors
Speaker Cables
6
7
Notes on multi-controller set-up______________________ 23
Zone Configuration ___________________________________ 7
Power Toggle Set-up
Source Component Set-up
“Engaged” Indicator
23
23
23
Basic Zone Complement
Loudspeakers
7
7
Installation: RMZ-955 Controller
8
System Set-up & Programming
24
AC Line Connections _________________________________ 8
Source Commands __________________________________ 24
Source Command Set-up ____________________________ 24
Power Toggle _______________________________________ 25
AC for the RMZ-955
8
8
8
8
AC for Source Components
Rotel RLC-900 AC line conditioner/switcher
Special AC features
Operating Instructions
26
Source connections __________________________________ 9
Source inputs
Source outputs
Speaker Connections ________________________________ 10
Preamp outputs _____________________________________ 11
Variable vs. Fixed Level
Data cable connections ______________________________ 12
Infrared Control System _____________________________ 13
Front Panel IR Flood Emitter
Rear Panel IR Repeaters
Paging Input ________________________________________ 14
9
9
RR-952 Hand-held Remote ___________________________ 26
Input Selector Buttons
Tuner control buttons
CD control buttons
Tape/Satellite TV control buttons
Video/LD control buttons
Mute
26
26
27
27
27
27
27
27
27
11
13
13
VOLUME UP/VOLUME DOWN
STBY
“X”
Paging Inhibit
14
RKP-901 Keypad _____________________________________ 28
Input Select commands
System commands
Source Control Commands
28
28
28
Installation: Zone Control Devices
15
RSM-901 Sensor/Display_____________________________ 15
RSM-901 Sensor/Display_____________________________ 29
RSM-901 Mounting
RSM-901 Data Connections
Battery Enable
15
16
16
16
16
16
17
17
Controls and Displays
Dot Matrix Display
Setting Alarm, Time, and Custom Functions
29
29
30
Zone Configuration
For Assistance ______________________________________ 31
Source Component Labels
Master/Slave Configuration
System Reset
Source Component Set-up
3
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-ROOM SYSTEM CONTROLLER RMZ-955
Getting Started
Component Description
The Rotel RMZ-955 Multi-Room Control System distributes audio
signals from a single set of source components to as many as
four separately controlled remote zones or listening areas. The
centrally located RMZ-955 controller/amplifier contains source
selection, microprocessor controlled communications circuitry
and independent preamplifier/power amplifiers for all zones.
RMZ-955 Controller/Amplifier
MULTI-ZONE CUSTOM CONTROLLER RMZ-955
DIGITALLY CONTROLLED AUDIO PROCESSING
POWER
Controlling the Remote Zones
ZONE
A
ZONE
B
ZONE
C
ZONE
D
ACTIVE CODE
ACTIVE CODE
ACTIVE CODE
ACTIVE CODE
I.R. TRANSMITTER
Users can select either of two ways to control remote zone op-
eration. The first is the RR-952 hand held remote. This generates
infrared (IR) control pulses read by the wall-mounted RSM-901
sensor/display. The RSM-901 sensor/display then transmits com-
mands to the RMZ-955 through hard-wired connections.
The RMZ-955 Controller/Amplifier is the heart of the RMZ-955
Multi-Room Control System, featuring:
The second method uses the wall-mounted RKP-901 keypad to
transmit commands directly to the RMZ-955. The RKP-901 is also
hard-wired to the RMZ-955 controller/amplifier.
• Four separate microprocessor-controlled stereo preamplifier/
power amplifier sections, one for each remote zone
• RCA inputs for up to four sources
Users can select a combination of sensor and keypad operation
for any zone. The system accepts inputs from up to three sensor/
displays and three keypads (for a total of six input devices) per
zone.
• “Loop through” RCA outputs which allow multiple RMZ-955 con-
trollers to be linked together for large systems up to 16 zones.
• RCA line level preamp outputs for use with external amplifier
systems. These outputs can be internally configured to provide a
variable level signal or a fixed level signal.
System Flexibility
The Rotel RMZ-955 Multi-Room Control System is exceptionally
flexible. In addition to the RMZ-955 controller/amplifier, a simple
two zone system might include just one RR-952 hand held con-
troller/RSM-901 IR sensor/display combination for one zone and
one RKP-901 keypad in the second.
• Screw-type quick connect speaker outputs
• Control data input for each zone is via industry-standard 6 pin
Methode connectors
In a more elaborate configuration, a single RMZ-955 accepts
commands from four separate zones via twelve IR sensor/dis-
plays and twelve keypads.
• 3.5 mm stereo jack “AC Link” connections for full system control
from any zone in large, multi-controller systems
• RCA output jack for RC-5 remote control protocol components
Up to four RMZ-955 controllers can be linked together for a sys-
tem with as many as sixteen independent zones.
• High power front panel IR flood emitter to transmit remote zone
commands to associated source components
System Highlights
• Four mini-plug IR repeater outputs
• Keypad or handheld remote operation of source components. No
programming required – built-in codes for Rotel and other popu-
lar components.
• Two polarized AC convenience outlets with 100 watts capacity
each: one switched to allow easy remote control of total system
power if desired, the other unswitched
• Single button operation for source selection and “play”.
• Full user control, including system standby from any zone.
• Built-in Paging input with muting in selected zones.
• Front panel LED indicators for Power On/Off, zone status, com-
mand pulse processing
• Near-universal Infra-red repeating system. Remote control avail-
able even when a zone is not active.
System Planning
• Alarm clock function with independent wake-up in each zone.
The RMZ-955 is designed to be used as a stand-alone control
center for a multi-zone distribution system using dedicated
source components. It features loop-through source connec-
4
Download from Www.Somanuals.com. All Manuals Search And Download.
GETTING STARTED
You’ll find details of the display in the Set Up and Operation sec-
tions of this manual.
RR-952 IR Remote Control
NOTE: An RSM-901 connected to the Zone A data input MUST be
used during initial set-up.
RKP-901 Keypad
The RR-952 infrared remote control serves a dual purpose. In ad-
dition to providing dedicated pushbuttons for the most needed
functions of both the RMZ-955 controller/amplifier and source
components, it also serves as a quick set-up tool during initial
configuration.
The RKP-901 is a wall-mounted keypad for convenient remote
operation of the entire system. The keypad can be used as a
stand-alone control device, although it is most functional when
installed with the RSM-901 sensor-display. Its 12 key design is
the optimum balance between flexibility and simplicity, providing
single-key control of the system and source components (select-
ing and starting a CD player, for example). In addition, the
RKP-901 allows total system shut-down from a remote location. It
mounts conveniently in a standard single width wall box or in a
dual width box with a RSM-901 sensor/display. (see page 25)
The RR-952 has a special high intensity IR transmitter. In con-
junction with the system’s sensitive receiver modules, this trans-
mitter assures reliable operation under a wide variety of
conditions.
RSM-901 Sensor/Display
RSM-901/RKP-901 Combination
Mounting both the sensor/display and keypad in one double-
width wall box carries several advantages. It simplifies the in-
stallation. It also focuses the user on one location in each zone,
i.e. walk to the keypad or aim the hand held remote control at the
same wall-plate.
The wall-mounted RSM-901 Sensor/Display receives commands
from the RR-952 hand held remote and, after processing to en-
sure maximum data integrity, sends these codes to the RMZ-955
controller/amplifier.
In addition, the RSM-901 provides continuous system status in-
formation (source, time, volume setting, etc.) at each remote lo-
cation with a dot matrix display. Also available is a
programmable alarm function.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-ROOM SYSTEM CONTROLLER RMZ-955
tions which allow linking additional RMZ-955 controllers for large
If the RMZ-955 is on an open shelf, the emitter’s signal must first
travel to an IR-reflective surface (an opposing wall, for example)
and then to the source component.
systems. Depending on the design of the associated compo-
nents, these pass-through source connections may alternatively
be used to “share” source components with a separate home
theater or audio system.
20 feet or less
AM/FM Tuner
Placement
Place the RMZ-955 on a stable surface in an equipment rack or
cabinet. Note that the RMZ-955 is slightly deeper than most
source components (tuners, CD players, cassette decks, etc.)
and should not generally be placed on top of these units.
Cassette Deck
CD Player
DVD Player
Connections:
RMZ-955 controller
Make sure that you have enough room to run all the connecting
cables and dress them appropriately behind the RMZ-955. Al-
though we’ll explain each connection fully in following sections
of this manual, glance through the following list of possible con-
nections and decide how much space you’ll need.
Keep total IR signal travel to 40' or less. Remember that it
must travel to a hard reflective surface and back again.
a) Four pair of RCA interconnects – one pair from each source.
b) Eight heavy gauge speaker cables (two for each zone).
Note: If an RSM-901 sensor display is located in the same room
as the RMZ-955 controller, it is essential that the output form the
front-panel IR flood emitter NOT reach the RSM-901 sensor. IR
loop problems can cause intermittent operation.
c) Four six-conductor + shield data cables, each terminated with
the proper IDC strip connector.
d) One shielded RCA to RCA interconnect for RC-5 remote control
code connection.
IR Repeater Jacks
The RMZ-955 also has four rear panel IR output jacks for use
with industry standard IR repeaters (made by Xantech and oth-
ers). The use of these external repeaters on each source compo-
nent is ideal in situations where output from the front panel flood
IR emitter is blocked from the source components by a door, full
depth shelf, etc. It is also an ideal solution when the front panel
flood emitter output could reach an RSM-901. When IR repeaters
are used, the front-panel flood emitter can be easily disabled.
e) One pair of RCA to RCA interconnects to power amplifiers from
each corresponding zone’s “Pre-out” terminals.
f) Up to four mini-plug (3.5 mm) cables from the RMZ-955’s “Infra
Red” outputs to remote IR transmitters.
g) Four more pair of RCA to RCA interconnect cables – one each to
the appropriate input of the next RMZ-955 in large multi-control-
ler systems.
h) Additional loudspeaker connections as required for systems us-
ing more than one RMZ-955 controller/amplifier.
System Wiring Considerations
i) 3.5 mm to 3.5 mm cable for AC “link” connections as required for
systems using more than one RMZ-955 controller/amplifier.
Data Cable and Connectors
The data path between the RMZ-955 controller/amplifier and
RSM-901 sensor/displays and RKP-901 keypads must be made
with cable with six insulated conductors plus a foil and/or
braided outer shield. We recommend a Belden 9536 equivalent
for best results. The RMZ-955 system data connectors work only
with cables using 24 gauge conductors. Make sure that all data
cables conform to this requirement.
j) Up to six “TX-FORM” terminal block jumper wires needed when
cascading multiple RMZ-955 controller/amplifiers.
We STRONGLY RECOMMEND that you attach a tag or strip to
each cable and wire to identify it (e.g. “To Input 3 from tape
deck.”). This will help in troubleshooting as well as make future
service calls or system add-ons much less frustrating.
Data cable termination is via industry-standard 6 pin IDC
connectors made by Methode and others. (The Methode part
number is 1300-106-424.) Data cable connection instructions are
found in the Installation section of this manual (see page 9).
IR Flood Emitter
The RMZ-955 has a high intensity front panel IR flood emitter de-
signed to transmit commands from the remote zones to the ap-
propriate source component. Although exact performance will
vary, this high power transmitter has an effective operating
range of approximately 40' under normal conditions.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
GETTING STARTED
Speaker Cables
Unshielded two conductor 18 gauge
(AWG) speaker wire is the minimum
acceptable standard for connections
between the RMZ-955 controller/
amplifier and zone loudspeakers. Par-
ticularly long runs may call for use of
heavier wire.
AM/FM Tuner
CD Player
Zone Configuration
Basic Zone Complement
Tape Deck
Each remote zone must include at
least one control device and a pair of
loudspeakers. The control device may
be a RR-952 hand held remote and an
RSM-901 sensor/display combination.
Or it can be a RKP-901 keypad, either
stand-alone or with a RSM-901.
LD/DVD Player
MULTI-ZONE CUSTOM CONTROLLER RMZ-955
DIGITALLY CONTROLLED AUDIO PROCESSING
POWER
Remember that the RSM-901 sensor/
display also provides useful visual
clues to total system operation and ad-
ditional convenience features. Most
zones will use multiple control devices,
with the combination of one RSM-901
sensor/display, one RKP-901 keypad,
and one RR-952 being the most com-
mon.
ZONE
A
ZONE
B
ZONE
C
ZONE
D
ACTIVE CODE
ACTIVE CODE
ACTIVE CODE
ACTIVE CODE
I.R. TRANSMITTER
Living Room
RECEIVE
CD
TUNER
VIDEO
AUX
MODE
HOUR
MIN
PM
VOLUME
DISC
OFF
*
ALARM
MUTE
The RSM-901 sensor/display reads in-
frared signals generated by the RR-952
hand held remote and, after translating
them into a digital code that is highly
resistant to interference, sends them
to the RMZ-955 controller/amplifier.
The RKP-901 simply translates key
pushes into digital code before send-
ing them to the controller/amplifier.
RR-952
RR-952
RR-952
RR-952
Family Room
RECEIVE
RECEIVE
RECEIVE
CD
TUNER
VIDEO
AUX
MODE
HOUR
MIN
PM
VOLUME
DISC
OFF
*
ALARM
MUTE
Loudspeakers
Bedroom
These will vary with installation
requirements and user expectations.
The RMZ-955’s amplifier sections are
optimized for impedance loads of four
ohms or higher.
CD
TUNER
VIDEO
AUX
MODE
HOUR
MIN
PM
VOLUME
DISC
OFF
*
ALARM
MUTE
Kitchen
CD
TUNER
VIDEO
AUX
MODE
HOUR
MIN
PM
VOLUME
DISC
OFF
*
ALARM
MUTE
7
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-ROOM SYSTEM CONTROLLER RMZ-955
The switched outlet provides the mechanism for “powering up”
Installation: RMZ-955 Controller
or “powering down” all of the source components from the re-
mote zones. We recommend plugging the AC power cords from
the source components into the switched outlet on the back of
the RMZ-955.
This section covers all hardware installation and configuration
issues related to the RMZ-955 controller, including wiring con-
nections for AC power, source connections, speaker connec-
tions, pre-amp connections, data cable connections to the
remote zones, Infrared control connections, and special features
such as the paging feature. The next section of the manual (see
page 12) covers similar topics related to the installation, wiring,
and hardware configuration of the zone control devices – the
RSM-901 Sensor/Display and the RKP-901 Keypad.
Rotel RLC-900 AC line conditioner/switcher
We strongly recommend the use of the RLC-900 AC line condi-
tioner/switcher to improve both the performance and convenient
operation of all system components. The RLC-900’s benefits in-
clude increased protection from AC power line surges and im-
proved system AC power management for proper turn-on and
turn-off sequences.
For the sake of simplicity, these two sections cover the installa-
tion of a basic 4-zone system with a single RMZ-955 controller,
since this is the most typical system configuration. There is a
separate section Installation: Multi-controller Systems (page 15)
that covers installation, wiring, and configuration topics related
to larger, more complex systems with multiple RMZ-955 control-
lers.
To incorporate the RLC-900, follow these steps:
a) Plug all system source components into the RLC-900’s “Digital
Equipment” or “Accessories” outlets as appropriate.
b) Plug the RMZ-955’s AC power cord into the RLC-900’s
“UNSWITCHED” outlet.
c) Plug the RLC-900’s “Control Cord” into the RMZ-955’s SWITCHED
AC Line Connections
outlet.
d) Plug the RLC-900’s “Main Power” cord into an unswitched AC
AC for the RMZ-955
outlet such as a wall receptacle, etc.
Plug the RMZ-955 controller/amplifier into an unswitched AC
source only, i.e. a wall outlet. It is essential for proper system op-
eration that the RMZ-955 be plugged into a constant source of
AC power, since it has “stand-by” circuitry that must receive
power for full control from any zone at any time.
When a system activation command is sent from a remote zone, the
RLC-900 turns on all source components automatically.
Special AC features
We recommend a powerline filter as the RMZ-955 contains a
number of microprocessor ICs that may benefit from the extra
protection afforded by a quality filter/surge protector.
Some source components power up in a standby mode when AC
power from a switched outlet turns them on. These components
require a separate command to fully activate them. The RMZ-955
has a built-in software function, called “power toggle” that can
handle this “power up” sequence, if necessary. This feature is
fully described in the System Set-up & Programming section of
this manual on page 22.
AC for Source Components
The RMZ-955 has two rear panel AC convenience outlets, one
switched and the other unswitched. These may be used to sup-
ply power for components used with the RMZ-955. Each outlet
carries a maximum load rating of 100 watts.
Unswitched AC outlet: The RMZ-955’s Unswitched AC outlet
supplies AC current whenever the RMZ-955 is plugged into a live
AC source. This outlet is NOT controlled by the setting of the
RMZ-955’s front panel power switch.
Switched AC outlet: This outlet provides a mechanism for con-
trolling AC power to other components, such as source compo-
nents. When the RMZ-955’s front panel switch is Off, the
switched AC outlet is also off. Even when the front panel switch
is turned On (i.e., when the RMZ-955 first powers up to
“Standby” mode), the switched outlet remains off until the
RMZ-955 receives a zone activation command from one of the
remote zones. The switched AC outlet then remains on until the
front panel power switch is turned Off or the RMZ-955 receives a
“system shutdown” command from a remote zone.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION: RMZ-955 CONTROLLER
Note 1: The RMZ-955 does not accept a phono cartridge’s output
directly. If required, use a separate phono preamp (such as
Rotel’s RQ-970BX) to boost phono signal to line level.
Source connections
The RMZ-955 has four pair of RCA inputs for four source compo-
nents, as well as four pair of RCA “loop-through” outputs that
can send the source signals to other components.
Note 2: Use only FIXED LEVEL source outputs to the RMZ-955.
Source outputs
Source inputs
Each source input on the RMZ-955 has a matching pair of “loop-
through” output RCA jacks. The primary use of these “loop-
through” outputs is to pass the signal from each source
component to additional RMZ-955 controllers in large multi-zone
systems (see page 15 for details on installing large systems).
Connect LINE LEVEL sources (CD player, tuner, etc.) to the
RMZ-955’s rear panel inputs as follows.
Using shielded RCA-RCA cables, connect the source’s output to
the corresponding source input on the RMZ-955. Connect analog
outputs from the source components as indicated to assure
clear operation with both the RR-952 hand held remote and the
RKP-901 keypad:
In some cases, these “loop-through” outputs may alternatively
be used to “share” the source components with a separate
home theater or audio system. If the source is shared by another
system, connect each pair of RMZ-955 source outputs to the
appropriate inputs of the main system’s preamplifier as shown in
the hook-up illustration.
Tuner
CD player
Tape deck / DSS Satellite
CD2 / VCR / DVD / LD
➠
➠
➠
➠
RMZ-955 Input 1
RMZ-955 Input 2
RMZ-955 Input 3
RMZ-955 Input 4
Note: The source sharing does not work with all combinations of
components. Specifically, home theater and audio systems with
micro-processor controlled source input switching may result in
problems such as interference or “mixing” between shared
sources.
Make sure to observe correct channel continuity from source to
RMZ-955. The RMZ-955’s RCA inputs are labelled for easy identi-
fication with Left Channel connections on the top row and Right
Channel connections on the bottom row.
TAPE MONITOR
IN OUT
INPUTS
CD AUX1
TUNER
AUX2
LINE OUT
PREAMPLIFIER
CAUTION
UNSWITCHED
SWITCHED
PAGING
WARNING:TO REDUCE THE RISK
OF FIRE OR ELECTRICAL SHOCK DO
NOT EXPOSE THIS EQUIPMENT TO
RAIN OR MOISTURE.
RISK OF ELECTRIC SHOCK
DO NOT OPEN
~
MULTI-ZONE CUSTOM CONTROLLER
MODEL NO. RMZ-955
POWER CONSUMPTION: 430W
LINK
IN
WE1
WE2
WE3
WE4
SPEAKER IMPEDANCE
T
X
O
U
T
AC120V
~
60HZ
4 OHM MINUMUM
LINK
OUT
DESIGNED AND MANUFACTURED
IN ENGLAND
N/C RC-5
P
U
T
ZONE D
ZONE C
ZONE B
SPEAKERS SPEAKERS
PRE-OUT
INPUTS
ZONE A
SPEAKERS
PRE-OUT
SPEAKERS
PRE-OUT PRE-OUT
1
2
3
4
TRIGGER
AUDIO IN
AUDIO OUT
S
LEFT RIGHT
LEFT RIGHT
LEFT RIGHT
LEFT RIGHT
DATA
L
DATA
DATA
1 2 3 4 5 6
DATA
TX-FORMAT
1 2 3 4 5 6
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
R
IN
OUT
IN
OUT
IN
OUT
IN
OUT
OUTPUT
RIGHT
LEFT
TUNER
Tuner connected to Source 1 input (with optional pass-through to preamp for shared use with separate system).
9
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-ROOM SYSTEM CONTROLLER RMZ-955
STOM CONTROLLER
4 OHM MINUMU
SPEAKER IMPED
Speaker Connections
NO. RMZ-955
SUMPTION: 430W
60HZ
The RMZ-955 is supplied with eight quick-connect screw termi-
nal plugs for speaker connections – one twin-terminal plug is
used for each speaker, two for each zone. Make the wire con-
nections from a speaker to a quick-connect plug and then insert
the plug into the appropriate receptacle on the back panel of the
RMZ-955, as illustrated.
~
0V
ZON
ACTURED
D MANUF
NGLAND
SPEAKERS
RIGHT
SPEAKERS
RIGHT
ZONE C
LEFT
–
+
–
+
RE-OUT
DA
LEFT
–
+
–
+
Strip back each speaker wire’s insulation by 1/4 inch. Insert the
bare wire into one “slot” on the quick-connect plug and secure
by tightening the corresponding clamping screw. Repeat for the
other conductor, making sure that there are no loose strands of
wire which could cause a short. Repeat for the second speaker
in zone one and then continue with the other zones.
A
T
1 2 3 4 5 6
Remember to observe proper polarity when connecting all loud-
speakers. The amplifier’s “+” output should connect to the
proper speaker’s “+” terminal. “Out of phase” loudspeaker hook-
ups (where one speaker in a stereo pair is inadvertently con-
nected “+” to “-” and vice versa) may not be immediately
noticeable but will not be as pleasing as a properly connected
stereo pair. BE CAREFUL AND BE PATIENT.
CAUTION
UNSWITCHED
SWITCHED
PAGING
WARNING:TO REDUCE THE RISK
OF FIRE OR ELECTRICAL SHOCK DO
NOT EXPOSE THIS EQUIPMENT TO
RAIN OR MOISTURE.
RISK OF ELECTRIC SHOCK
DO NOT OPEN
~
MULTI-ZONE CUSTOM CONTROLLER
MODEL NO. RMZ-955
POWER CONSUMPTION: 430W
LINK
LINK
IN
WE1
WE2
WE3
WE4
SPEAKER IMPEDANCE
T
X
O
U
T
AC120V
~
60HZ
4 OHM MINUMUM
OUT
DESIGNED AND MANUFACTURED
IN ENGLAND
N/C RC-5
P
U
T
ZONE D
ZONE C
ZONE B
SPEAKERS SPEAKERS
PRE-OUT
INPUTS
ZONE A
SPEAKERS
PRE-OUT PRE-OUT
SPEAKERS
1
2
3
4
TRIGGER
AUDIO IN
AUDIO OUT
S
PRE-OUT
LEFT RIGHT
LEFT RIGHT
LEFT RIGHT
LEFT RIGHT
L
DATA
DATA
1 2 3 4 5 6
DATA
DATA
1 2 3 4 5 6
TX-FORMAT
1 2 3 4 5 6
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
1 2 3 4 5 6
1 2 3 4 5 6
R
IN
OUT
IN
OUT
IN
OUT
IN
OUT
SPEAKERS
LINE IN
–
+
POWER
AMPLIFIER
LEFT
RIGHT
–
+
–
+
–
+
–
+
SPEAKER
INPUTS
SPEAKER
INPUTS
SPEAKER
INPUTS
SPEAKER
INPUTS
LEFT
RIGHT
LEFT
RIGHT
Speaker connections from Zone D of RMZ-955
Also showing Zone C preamp output connections
for use with optional power amplifier
10
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION: RMZ-955 CONTROLLER
The long runs from amplifier to speaker typically found in multi-
zone installations demand heavy gauge, low resistance speaker
wire. Small diameter wire reduces effective amplifier power and
adds substantial distortion to the audio signal. Avoid problems by
following these minimum recommendations:
RMZ-955 Circuit Board
back
ZONE A
ZONE B
ZONE C
ZONE D
Under 150'
150' - 300'
➠
➠
18 gauge wire
16 gauge wire
Loudspeaker runs over 300' are discouraged.
front
P R E - O U T
1
1 5
L I N E D R I V E R
1
1 5
Preamp outputs
Two RCA jacks (Left and Right Channel) labeled “Pre-out” pro-
vide line level outputs for each of the four zones. These are pri-
marily used for systems with external power amplifiers driving
speakers in one or all of the remote zones.
1
1
15
LINE DRIVER
1
1
15
15
PRE-OUT
15
Each zone’s preamp output is fully buffered and may be used ei-
ther independently or along with the RMZ-955’s internal amplifi-
ers to provide additional flexibility for demanding installations.
Factory default:
variable level
pre-amp output
For fixed-level line-driver
output, remove module,
rotate 180° and reinstall
using other set of pins.
If a zone requires additional amplification, use standard RCA-
RCA shielded interconnects from these outputs to a separate
power amplifier’s unbalanced line inputs as shown in the hook-
up illustration on the preceding page. Connect the left channel
“Pre-out” jack to the left channel input on the power amplifier
for that zone; then repeat for the right channel connections.
Note that the side of the module with the actual electronic com-
ponents remains facing to the left side of the RMZ-955, regard-
less of which set of header pins you use. Also note that the pins
and the socket are labeled 1 — 15. Pin 1 is always inserted into
Socket 1, etc.
Note You can configure each of the four zones independently, by
rotating just its module. Some zones can be configured as vari-
able outputs, while others are reconfigured as fixed outputs by
reorienting some or all of the modules.
Variable vs. Fixed Level
As delivered, the preamp outputs are configured to provide a
variable level output, i.e. the volume level of the signal can be
adjusted with a volume control in each zone. Alternatively, the
pre-amp outputs for one or more zones can be converted to pro-
vide a fixed level line drive signal, i.e. a signal that is always at a
fixed gain (0.25dBV below that of the source component). This
may be useful in certain custom applications.
Converting the pre-amp outputs to fixed level operation requires
removing the top cover of the RMZ-955 and locating the four
“line driver” plug-in modules. Looking from the front of the unit,
these are small vertical circuit boards located in front of the heat
sink. They are labeled Zone A through Zone D, from left to right.
Notice that the modules are printed circuit boards that plug into
the main board. Each module has two rows of “pins”, one on the
bottom (which is plugged into a socket as delivered from the fac-
tory) and the other pointing up. To reconfigure from variable level
pre-amp outputs to fixed level pre-amp outputs, simply remove
the module from the socket on the main circuit board, rotate it
180 degrees, and reinsert it in the same socket using the row of
pins on the opposite end.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-ROOM SYSTEM CONTROLLER RMZ-955
The supplied Methode connectors need to be crimped to lock to
the data cable’s 24 gauge conductors.
Data cable connections
Note: Do not use a screwdriver, metal ruler or knife blade to
“crimp” these connections. You may think these tools will work
but you will be mistaken. USE THE DEDICATED CRIMPING TOOL
SPECIFICALLY DESIGNED FOR THESE CONNECTORS. This tool is
available from Rotel.
Data communication to and from the RMZ-955 controller and the
remote zones’ RSM-901 sensor/displays and RKP-901 keypads is
by 6 conductor shielded cable.
Note: One, and only one, data cable runs from the RMZ-955 to
each zone. Multiple sensor/display and keypad combinations in
one zone should be wired via series connections detailed in the
section on Zone Connection Strategies (page 15).
• Strip about 1.5" of the outer cable insulation using a sharp knife.
Separate the outer shield from the conductors and trim it off
flush with the outer insulation, being careful not to trim off the
shield or “drain” wire.
We recommend the use of Belden 9536 cable or the equivalent.
The Methode data connectors supplied with the RMZ-955 only
accept cable with 24 gauge conductors.
• DO NOT strip insulation off the six individual conductors as the
connector automatically makes contact with the conductor core
when crimped.
Using cable with a foil and/or braided shield is absolutely essen-
tial in maintaining data integrity over the long runs between the
controller/amplifier and a zone’s control code generating de-
vices. Make sure that the shield is firmly connected at both the
RMZ-955 and at any command device terminal.
• Place the shield or “drain” wire into slot 1 of the connector.
Then, place the BLACK conductor immediately on top of the
drain wire in slot 1, hold them both in place and push the crimp-
ing tool handle until you hear a slight “click.” Both conductors
should now be locked into slot 1. The rachet action of the crimp-
ing tool ensures proper connection. The clicking sound tells you
that the connector slot contacts have pierced the conductor’s
insulation.
We recommend that you run each zone’s data cable and speaker
cables together to save time. There is absolutely no performance
penalty for doing so.
PROPER DATA CABLE TERMINATION IS CRITICAL. All connec-
tions for RMZ-955 and the remote zone’s RSM-901 sensor/dis-
plays and RKP-901 keypads use the color code shown in the
following illustration:
• Continue the process following the color code guide above until
all other conductors are locked in the appropriate connector
slots. Remember that slot 1 is the ONLY ONE to get the drain
wire and a conductor. All other slots receive only a conductor.
After attaching the cable conductors to the connector, insert it
into the appropriate zone’s 6 pin data terminal on the RMZ-955’s
rear panel. Be careful to center the connector over the terminal
pins before inserting.
DATA CONNECTOR
WIRING CODE
1
2
3
4
5
6
The maximum cable length for guaranteed operation is 300'.
Longer lengths may be practical in some installations with low
RF (radio frequency) and EMI (Electro-Magnetic Interference).
Pin 1• black & shield
Pin 2• white
Pin 3• red
Pin 4• brown
Pin 5• blue
Pin 6• green
Connections are made
in the same order at
both ends of the cables.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION: RMZ-955 CONTROLLER
To disable the IR flood emitter, remove the jumper wire between
screws 2 and 3 of the TX FORMAT terminal block located on the
lower right hand side of the RMZ-955’s rear panel.
Infrared Control System
The RMZ-955’s IR system provides extensive control flexibility
accepting remote control codes generated by keypads and/or
hand-held remotes, relaying them to the system controller, and
passing them along to the source components via a front-panel
flood emitter or individual remote IR emitters plugged into the
rear panel. However, please note the following points:
Optional remote IR emitters
for use in place of front panel
IR flood emitter. One required
for each source component.
CAUTION
WARNING:TO REDUCE THE RISK
OF FIRE OR ELECTRICAL SHOCK DO
NOT EXPOSE THIS EQUIPMENT TO
RAIN OR MOISTURE.
RISK OF ELECTRIC SHOCK
DO NOT OPEN
The IR codes generated by the RR-952 hand held remote are
RMZ-955 “system specific” codes and ARE NOT the same codes
generated by a source component’s own controller, even for
functions that appear identical such as “CD play,” for example.
In other words, you can not use the RR-952 to directly control a
Rotel CD player but must use it through an RSM-901 sensor/dis-
play from a remote zone.
WE1
WE2
WE3
WE4
SPEAKER IMPEDANCE
T
X
O
U
T
4 OHM MINUMUM
N/C RC-5
P
U
T
ZONE B
EAKERS SPEAKERS
PRE-OUT
ZONE A
SPEAKERS
PRE-OUT
S
T
+
RIGHT
LEFT RIGHT
LEFT RIGHT
DATA
DATA
1 2 3 4 5 6
TX-FORMAT
1 2 3 4 5 6
–
+
–
+
–
+
–
+
–
+
1 2 3 4 5 6
The RMZ-955 IR control system does the following:
• An RSM-901 sensor/display receives the remote’s code se-
quence and translates it into proprietary 5 bit digital code.
Remove this jumper to disable front
panel IR flood emitter.
• This digital code travels over the data cable to the RMZ-955
controller/amplifier.
NOTE: There is a very low intensity red LED mounted behind the
emitter’s window which flashes whenever it is transmitting IR
codes. Use this LED to verify the emitter’s operating status.
• The RMZ-955’s translator card restores the code’s original con-
figuration (when required) and sends it to both the IR flood emit-
ter and the rear panel IR outputs for use by the appropriate
source component.
Rear Panel IR Repeaters
In addition to passing RMZ-955 system codes, the IR system will
pass ALMOST any IR code sequence from an RSM-901 to a
source component. (These few exceptions use a non-standard
IR transmission frequency.) This allows you to control transport
functions of a VCR from a remote zone, for example, with the
VCR’s dedicated hand held remote.
In many system configurations, the most reliable, trouble-free
means of passing IR control codes to the source components is
with individual IR emitters, one for each source. Use these op-
tional repeaters in situations where the RMZ-955 will be located
some distance away from the source components or where the
IR flood emitter may have difficulty transmitting reliable source
control data. Disable the flood emitter when using the optional IR
remote emitters.
Front Panel IR Flood Emitter
The RMZ-955 features a front-panel flood emitter for sending IR
codes to the source components own front-panel IR sensors.
The RMZ-955 rear panel has four paralleled 3.5mm mini-plug
sockets labeled “TX OUTPUTS.” They accept standard “stick on”
IR emitter like Xantech’s Video Link 282-00. Plug a repeater into
one of the sockets and place it over the source component’s IR
sensor. Repeat for the other three sources.
Note: It is essential that the output of the front-panel flood emit-
ter NOT be allowed to reach an RSM-901 sensor/display. This
could result in an IR loop and unstable system operation includ-
ing “lock-up”
Note: Some source components, such as some Rotel sources, al-
low a direct connection from a 3.5 mm rear panel IR emitter con-
nection to a matching 3.5 mm connection on the source
component, eliminating the need for stick-on IR emitters.
RMZ-955s are shipped with the front panel IR flood emitter en-
gaged. However, there may be applications (system installations
on open shelves in very large, bright rooms, for example) where
the IR flood emitter might interfere with proper source compo-
nent operation or will not be particularly effective in communi-
cating control pulses. Or, there may be systems where an
RSM-901 display/sensor located in the same room as the RMZ-
955. In these cases, disable the front-panel flood emitter and use
individual IR emitters connected the RMZ-955’s rear panel and
placed over each source components IR sensor.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-ROOM SYSTEM CONTROLLER RMZ-955
Paging Inhibit
Paging Input
The paging function is individually configurable for each zone.
The installer can select which Zones will receive or not receive
an announcement when the paging is activated. Each Zone has
an internal micro switch which is used to set the paging function
ON/OFF for that zone. These switches are accessed by removing
the top cover of the RMZ-955 by a qualified technician. Make
sure that the AC power line is disconnected before removing
the cover.
The paging input allows announcements to be made over the
system, and, if required, for Zones to be momentarily muted, in
conjunction with a doorbell or a phone system.
The paging feature needs to be activated from an external
source via the “paging trigger” RCA-type input jack on the back
of the RMZ-955. Any device which shorts the trigger input will
cause the controller to enter its paging mode. For example, a
doorbell, a phone system , or a keyed announcement micro-
phone system could provide this control.
RMZ-955 Circuit Board
back
The “Paging Audio In” RCA jack is connected to the audio output
of the announcement system (phone or microphone amplifier).
The “Paging Audio Output” jack can be connected to the Paging
Audio Input on a second controller (in a large multi-controller
system) or to the RCA input of an external amplifier.
ZONE A
ZONE B
ZONE C
ZONE D
front
PAGING ON
PAGING OFF
Notes:
If a Zone is in Standby (or is listening to Input 1, 2, or 3) and its
paging switch is set to OFF, the Zone will remain in its present
status when the paging is activated for the rest of the system. It
will not be muted and no announcement will be heard.
Door Bell
Relay
(if required)
If a Zone is listening to Input 4, the paging input will be heard
when activated, regardless of whether its paging switch is set to
ON or OFF.
trigger
audio
trigger
Phone
System
Microphone
Amplifier
UNSWITCHED
SWITCHED (RLC-900)
100W MAX AC 120V 60HZ 100W MAX AC 120V 60HZ
MULTI-Z
POW
DESIG
PAGING
ZONE D
INPUTS
SPEAKERS
PRE
3
4
TRIGGER
AUDIO IN
AUDIO OUT
LEFT RIGHT
DATA
1 2 3 4 5 6
–
+
–
+
OUT
IN
OUT
IN
OUT
paging audio output to
paging audio input
on second RMZ-955
14
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION: ZONE CONTROL DEVICES
RSM-901 Mounting
Installation: Zone Control Devices
The RSM-901 Sensor/Display mounts in a single-width wall box
or in a double width box with the RKP-901 keypad.
PLACEMENT SUGGESTIONS: Exact placement will vary with
each installation but we strongly recommend AGAINST place-
ment where the RSM-901 will be exposed to direct sunlight, pow-
erful fluorescent illumination or the output of a high intensity
spotlight, etc. These light sources contain high levels of infrared
energy themselves and may cause intermittent operation by
saturating the RSM-901.
RSM-901 Sensor/Display
RECEIVE
Note: Avoid infrared “loops” by making sure that an RSM-901
sensor/display is not placed where it might pick up signals from
a source component’s IR repeater or the RMZ-955’s IR front
panel flood emitter.
MODE
PM
HOUR
ALARM
MIN
Lastly, make sure that each RSM-901 is on a relatively uninter-
rupted “line-of-sight” path to all likely locations from which the
hand held RR-952 remote might be used. You’ll find the RSM-901/
RR-952 combination much less susceptible to signal interference
than other IR remote control links, but planning will ensure de-
pendable operation under an even wider variety of conditions.
RECEIVE
CD
TUNER
VIDEO
CD
TUNER
VIDEO
AUX
AUX
MODE
HOUR
MIN
VOLUME
VOLUME
PM
DISC
OFF
DISC
OFF
*
*
ALARM
MUTE
MUTE
IN
IN
OUT
OUT
OUT
CAUTION
UNSWITCHED
SWITCHED
WARNING:TO REDUCE THE RISK
OF FIRE OR ELECTRICAL SHOCK DO
NOT EXPOSE THIS EQUIPMENT TO
RAIN OR MOISTURE.
RISK OF ELECTRIC SHOCK
DO NOT OPEN
~
MULTI-ZONE CUSTOM CONTROLLER
MODEL NO. RMZ-955
POWER CONSUMPTION: 430W
LINK
LINK
IN
WE1
WE2
WE3
WE4
SPEAKER IMPEDANCE
T
X
O
U
T
AC120V
~
60HZ
4 OHM MINUMUM
OUT
DESIGNED AND MANUFACTURED
IN ENGLAND
N/C RC-5
PAGING
P
U
T
ZONE D
ZONE C
ZONE B
SPEAKERS SPEAKERS
PRE-OUT
INPUTS
ZONE A
SPEAKERS
PRE-OUT
SPEAKERS
PRE-OUT PRE-OUT
1
2
3
4
TRIGGER
AUDIO IN
AUDIO OUT
S
LEFT RIGHT
LEFT RIGHT
LEFT RIGHT
LEFT RIGHT
DATA
L
DATA
DATA
1 2 3 4 5 6
DATA
TX-FORMAT
1 2 3 4 5 6
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
R
IN
OUT
IN
OUT
IN
OUT
IN
OUT
OUT IN OUT IN
OUT IN OUT IN
OUT
RECEIVE
RECEIVE
CD
TUNER
CD
TUNER
CD
TUNER
VIDEO
AUX
VIDEO
AUX
VIDEO
AUX
MODE
HOUR
MIN
MODE
HOUR
MIN
VOLUME
VOLUME
VOLUME
PM
PM
DISC
OFF
DISC
OFF
DISC
OFF
*
*
*
ALARM
ALARM
MUTE
MUTE
MUTE
15
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-ROOM SYSTEM CONTROLLER RMZ-955
RSM-901 Data Connections
Zone Configuration
Prepare the data cable with the supplied termination plug using
the same color coding as previously described for the RMZ-955.
Each RSM-901 must be configured or “addressed” as being in
Zone A, Zone B, Zone C, or Zone D. You select the proper zone by
setting Switches 1 & 2 on the DIP switch shown in the illustra-
tion. Use the following settings:
ON
DIP SWITCH
See instructions for
configuration settings
Zone
A (default)
Switch 1
OFF
Switch 2
OFF
1
2
3
4
5
6
B
C
D
OFF
ON
ON
ON
OFF
ON
RESET SWITCH SW1
Press after changing
configuration
OFF
Source Component Labels
Each RSM-901 must be configured to display the correct label for
each source component. It always displays “Tuner” for source
input 1 and “CD” for source input 2. However, source input 3 can
display “Tape” or “Sat” depending on the setting of Switch 3 and
source input 4 can display “CD2”, “VCR”, “Ld”, or “DVD” de-
pending on the setting of Switch 4 and Switch 5. Use the follow-
ing settings:
ON
1
2
3
4
5
6
OFF
Source Input 3
Tape (default)
Sat
Switch 3
OFF
ON
IN
OUT
Source Input 4
CD2
Switch 4
ON
Switch 5
ON
VCR
LD
DVD (default)
ON
OFF
OFF
OFF
ON
OFF
JUMPER 1
install jumper
to enable battery
backup
INPUT DATA CONNECTOR
Connect to RKP-901 Keypad or
slave RSM-901 display/sensor
OUTPUT DATA CONNECTOR
Connect to RMZ-955
controller/amplifier
Note: Remember to set these switches on all RSM-901s.
Note that each RSM-901 has two data terminals labeled “In” and
“Out” respectively. Connect the remote zone end of the data
cable from the RMZ-955 to the “Out” connector on the RSM-901.
Master/Slave Configuration
Each RSM-901 must be configured as a Master or Slave by set-
ting Switch 6. Because it is possible to have more than one
RSM-901 in any zone, follow the simple rules to ensure that the
required functions are available:
The “In” connector is used to “daisy-chain” additional RSM-901
display/sensors or RKP-901 keypads in the same zone. See Zone
Connection Strategies on page 15 for details.
Each zone used in a system must have a Master RSM-901. In a
zone with more than one RSM-901, only one must be set as a
Master and each other must be set as a Slave. The Master must
be the first device on the data cable to the zone from the
RMZ-955.
A number of configuration settings must be made using the
switches and jumpers on the back of the RSM-901. These are de-
tailed below.
Battery Enable
The Master/Slave settings for Switch 6 are:
Each RSM-901 has a rechargeable back-up battery which main-
tains the clock and configuration information when power to the
controller is switched off. When fully charged, the battery will
then maintain the configuration information for several weeks.
Master/Slave
Master
Slave
Switch 6
OFF (default)
ON
The battery must be enabled when the RSM-901 is installed. To
enable the battery, place the jumper JP1 to link the two pins as
shown in the illustration above.
Note: Clock and Alarm functions can only be set from a Master.
Note: After initial installation, leave the RMZ-955 turned on con-
tinuously for a few days to ensure that the battery is charged.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION: ZONE CONTROL DEVICES
System Reset
After changing any of the above configurations, reset the
RSM-901 by pressing the RESET switch (SW1). This is essential
to allow the new setting to take effect.
RECEIVE
CD
TUNER
VIDEO
AUX
Source Component Set-up
After installation, refer to System Set-up and Programming (page
21) for configuring the proper data codes for source component
operation.
MODE
HOUR
MIN
VOLUME
PM
DISC
OFF
*
ALARM
MUTE
Remember that an RSM-901 connected to the Zone A data cable
terminal MUST be used for initial set-up, particularly in systems
where non-Rotel source components are included.
Note: After completing the installation and component set-up,
power down the system, wait approximately 30 seconds, and
then power it up again. Test all functions.
RKP-901 Data Connections
RKP-901s do not need to be set for particular zones or configured
as Master/Slaves because they do not display zone or system
status information.
Data cable terminations and connections are made the same
way as previously detailed. As does the RSM-901, each RKP-901
has two data terminals (“In” and “Out”) located at the bottom of
its circuit board. Connect the “Out” terminal, either to the “In”
terminal of an RSM-901 in the zone, or to the RMZ-955 controller
if the zone does not have a RSM-901.
RKP-901 Keypad
CD
TUNER
VIDEO
AUX
VOLUME
DISC
OFF
*
MUTE
RKP-901 Mounting
IN
OUT
The RKP-901 keypad mounts in a wall box in the same manner as
the RSM-901 sensor/display. There are no restrictions on where
the RKP-901 can be located. Common sense and user conve-
nience should be the determining factors. Alternatively, the
RKP-901 can be mounted in a double-width wall box with an
RSM-901 sensor/display. This is the most sensible arrangement
from an installation viewpoint (fewer cable runs) but may not be
practical in all rooms.
INPUT DATA CONNECTOR
Connect from output of
RKP-901 or subsequent
RSM-901 in the zone.
OUTPUT DATA CONNECTOR
Connect to RSM-901 Input
or to RMZ-955 if used
without RSM-901
17
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-ROOM SYSTEM CONTROLLER RMZ-955
Installation: Multi-controller Systems
Zone Connection Strategies
Each RMZ-955 provides independently controlled audio distribu-
tion from four sources to four separate zones. To satisfy the re-
quirements of more elaborate systems, up to four RMZ-955s can
be cascaded to build a system with as many as 16 independent
zones. Under these circumstances, all RMZ-955 controller/ampli-
fiers share one set of four source components.
Each zone will support up to three RSM-901s and three
RKP-901s. All of the command devices for one zone should con-
nect to each other in serial fashion using their appropriate cir-
cuit board-mounted “In” and “Out” terminals.
Each RSM-901 signals when it receives and processes a com-
mand. This happens regardless of whether the command was
generated by a keypad or a hand held remote. However, a key-
pad located “downstream” of a sensor/display will not trigger
that sensor’s command processing indicator.
When system complexity calls for more than one RMZ-955, we
have no cautions about stacking controller/amplifiers on top of
each other. As long as there is sufficient room to allow relatively
unrestricted air flow, heat should not be a problem.
Whenever possible, we suggest that you configure each zone so
that all keypads are “upstream” from all sensor/displays. Al-
though not always practical depending on the zone configura-
tion, this arrangement will reduce user confusion.
In most respects, installing a multi-controller system is no differ-
ent than a single controller system. Source input connections,
speaker output connections, data cable connections to the re-
mote zones, and other configuration steps are essentially the
same. Review Installation: RMZ-955 Controller (page 5) for com-
plete information.
Regardless of other considerations, we suggest that you always
wire an RSM/RKP double wall box so that the RSM is located
“downstream” from adjacent RKP (i.e., between the RKP and the
RMZ-955 controller/amplifier). This assures that the sensor/dis-
play always signals the user when the adjacent keypad is used.
There are, however, some additional considerations and installa-
tion steps required for a system with multiple RMZ-955 control-
lers. These steps all deal with the need to link the controllers:
Installation is the first step towards enjoying an RMZ-955 system.
Proper set-up ensures that the RMZ-955 will function optimally
with all associated source components and provide total system
control.
a) AC connections for fully-integrated system control
b) Sharing four sources among all controllers
c) Passing IR commands from one controller to the rest
d) Linking special features like system-wide paging
All hookup instructions in this section assume that Zones 1-4
will be handled by the first RMZ-955 (called “A”), Zones 5-8 by
the RMZ-955 immediately above it (“B”), Zones 9-12 by third
unit (“C”), and Zones 13-16 by the top unit (“D”). In most cases,
we do not illustrate all four controllers, as additional controllers
are merely added in the same fashion as the second or third con-
troller.
There is no functional distinction between the first RMZ-955 and
additional controllers in a system. However, for convenience and
simplicity, we assume that the first controller will handle some
additional responsibilities, such as source inputs and sending IR
signals to the sources. This approach makes it easy on the in-
staller, particularly when starting with a single RMZ-955 and later
expanding with additional controllers. Essentially, the work done
installing a single RMZ-955 remains unchanged and additional
zones are handled by “add-on” RMZ-955 controllers.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION: MULTI-CONTROLLER SYSTEMS
Optional +5V external trigger
RMZ-955 "C"
CAUTION
UNSWITCHED
SWITCHED
WARNING:TO REDUCE THE RISK
OF FIRE OR ELECTRICAL SHOCK DO
NOT EXPOSE THIS EQUIPMENT TO
RAIN OR MOISTURE.
RISK OF ELECTRIC SHOCK
DO NOT OPEN
~
MULTI-ZONE CUSTOM CONTROLLER
MODEL NO. RMZ-955
POWER CONSUMPTION: 430W
LINK
LINK
IN
WE1
WE2
WE3
WE4
SPEAKER IMPEDANCE
T
X
O
U
T
AC120V
~
60HZ
4 OHM MINUMUM
OUT
DESIGNED AND MANUFACTURED
IN ENGLAND
N/C RC-5
PAGING
P
U
T
ZONE D
ZONE C
ZONE B
SPEAKERS SPEAKERS
PRE-OUT
INPUTS
ZONE A
SPEAKERS
PRE-OUT
SPEAKERS
PRE-OUT PRE-OUT
1
1
1
2
2
2
3
4
TRIGGER
AUDIO IN
AUDIO OUT
S
LEFT RIGHT
LEFT RIGHT
LEFT RIGHT
LEFT RIGHT
DATA
L
DATA
1 2 3 4 5 6
DATA
1 2 3 4 5 6
DATA
1 2 3 4 5 6
TX-FORMAT
1 2 3 4 5 6
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
1 2 3 4 5 6
R
IN
IN
IN
OUT
OUT
OUT
IN
OUT
IN
OUT
IN
OUT
RMZ-955"B"
CAUTION
UNSWITCHED
SWITCHED
WARNING:TO REDUCE THE RISK
OF FIRE OR ELECTRICAL SHOCK DO
NOT EXPOSE THIS EQUIPMENT TO
RAIN OR MOISTURE.
RISK OF ELECTRIC SHOCK
DO NOT OPEN
~
MULTI-ZONE CUSTOM CONTROLLER
MODEL NO. RMZ-955
POWER CONSUMPTION: 430W
LINK
LINK
IN
WE1
SPEAKER IMPEDANCE
T
X
O
U
T
AC120V
~
60HZ
4 OHM MINUMUM
OUT
DESIGNED AND MANUFACTURED
WE2
WE3
WE4
IN ENGLAND
N/C RC-5
PAGING
P
U
T
ZONE D
SPEAKERS
ZONE C
ZONE B
INPUTS
ZONE A
PRE-OUT PRE-OUT
SPEAKERS SPEAKERS
SPEAKERS
3
4
TRIGGER
AUDIO IN
AUDIO OUT
S
PRE-OUT
PRE-OUT
LEFT RIGHT
LEFT RIGHT LEFT RIGHT
LEFT RIGHT
L
DATA
1 2 3 4 5 6
DATA
1 2 3 4 5 6
DATA
1 2 3 4 5 6
DATA
1 2 3 4 5 6
TX-FORMAT
1 2 3 4 5 6
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
R
IN
OUT
IN
OUT
IN
OUT
RMZ-955 "A"
CAUTION
UNSWITCHED
SWITCHED
WARNING:TO REDUCE THE RISK
OF FIRE OR ELECTRICAL SHOCK DO
NOT EXPOSE THIS EQUIPMENT TO
RAIN OR MOISTURE.
RISK OF ELECTRIC SHOCK
DO NOT OPEN
~
MULTI-ZONE CUSTOM CONTROLLER
MODEL NO. RMZ-955
POWER CONSUMPTION: 430W
LINK
LINK
IN
WE1
SPEAKER IMPEDANCE
T
X
O
U
T
AC120V
~
60HZ
4 OHM MINUMUM
OUT
DESIGNED AND MANUFACTURED
WE2
WE3
WE4
IN ENGLAND
N/C RC-5
PAGING
P
U
T
ZONE D
SPEAKERS
ZONE C
ZONE B
INPUTS
ZONE A
PRE-OUT PRE-OUT
SPEAKERS SPEAKERS
SPEAKERS
3
4
TRIGGER
AUDIO IN
AUDIO OUT
S
PRE-OUT
PRE-OUT
LEFT RIGHT
LEFT RIGHT LEFT RIGHT
LEFT RIGHT
L
DATA
1 2 3 4 5 6
DATA
1 2 3 4 5 6
DATA
1 2 3 4 5 6
DATA
1 2 3 4 5 6
TX-FORMAT
1 2 3 4 5 6
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
R
IN
OUT
IN
OUT
IN
OUT
Source component
OUTPUT
RIGHT
LEFT
TUNER
For multi-contoller systems, connect source sharing links (connections
shown on left side), AC control links (connections shown in center),
and IR repeater links (connections shown on right side).
19
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-ROOM SYSTEM CONTROLLER RMZ-955
“power down” command is given from any zone, the RMZ-955
controllers go into Standby mode, the rear panel switched AC
outlets are shut off, and this control signal goes to 0V.
AC Power
Multiple controller systems require handling AC connections in a
way that allows any zone to “power up” or “power down” the
system. In other words, there must be a provision for zones con-
nected to additional RMZ-955 controllers to control the system’s
switched AC outlets.
This external trigger requires the same 3.5 mm stereo mini-jack
as the “AC Link” connections. The “tip” of the connector carries
the +5V DC control voltage.
Manual AC Override
A special feature of the RMZ-955, called “AC Link” simplifies the
installation of multi-controller systems with a simple control line
connection between units for AC control.
There is a provision to manually override the “AC Link” control of
the switched outlets. While not common, there may be custom
system configurations where being able to manually power up all
of the switched outlets and components connected to them.
AC Connections
To enable the manual override, connect Pin 1 and Pin 6 of the
rear panel TX FORMAT jumper block with a jumper wire. As long
as these two pins are connected, the switched AC outlets on all
RMZ-955’s will be powered on. When the two pins are uncon-
nected, control of the AC outlets will revert to standard control
from the zones, depending on whether the system has been acti-
vated from a zone or not.
Plug all RMZ-955 controllers into unswitched AC outlets, provid-
ing a constant AC supply.
Plug all source components into the switched outlets located on
the rear panels of the RMZ-955 controllers. As in a single-con-
troller system, the recommended approach is to use a Rotel RLC-
900 power conditioner/switcher in conjunction with the first
RMZ-955’s rear panel outlets. This allows the first RMZ-955 to
handle all AC switching for the system.
In practice, the manual override jumper described above would
be replaced with a simple single-pole switch connected be-
tween Pin 1 and Pin 6 of the “TX-FORM” block. When the switch
is closed, manual override is active. When the switch is open,
activation of the AC outlets reverts to standard zone control.
With the “AC Linking” feature, it is also possible to plug source
components into any switched outlet on the rear panel of any
RMZ-955. All of these outlets are controlled in unison. When the
system is “powered up” from any zone, the switched outlets on
the first RMZ-955 and all other controllers are turned on. When a
“power down” command is sent, all RMZ-955’s go into standby
and their rear panel switched outlets are turned off.
TX-FORMAT
1 2 3 4 5 6
TX-FORMAT
1 2 3 4 5 6
AC Link
Unified AC control in multi-controller systems is achieved by a
special “AC Link” connection from the first RMZ-955 to the sec-
ond and so on down the line. This connection uses standard 3.5
mm stereo mini-jacks at both ends of a 3-conductor cable.
To manually turn on all
switched AC outlets, connect
pins 1 & 6 with a jumper
or closed switch
For automatic system
control of switched AC
outlets, remove jumper
or open switch
Note: It is essential to use a stereo mini-jack for the “AC Link”
connection between controllers (such as Radio Shack #274-389).
Do not substitute a mono 2-conductor cable.
Note: In multi-controller systems, Pin 6 must be connected from
the first controller to the Pin 6 on the next, and so on daisy-
chainging all RMZ-955s to enable the manual override.
To make the connection, plug one end of the 3.5 mm stereo cable
into the 3.5 mm jack labeled “Link Out” on the first RMZ-955.
Then plug the other end of the cable into the jack labeled “Link
In” on the second RMZ-955. Then link the second RMZ-955 by
connecting its “Link Out” to the third RMZ-955’s “Link In” jack
with another cable. And, so on until there is an “AC Link” con-
nection between all RMZ-955 controllers.
Source Connections
Multi-controller systems share the same four source compo-
nents. Therefore, it is necessary to pass the signal from each
source to all of the RMZ-955 controllers in a system.
External 5V Trigger: Once you have completed all of the “AC
Link” connections, the “Link Out” connector on the last RMZ-955
is still available. This jack can provide a +5V D.C. control voltage
that could be used to activate external devices in an elaborate
custom system. When the Rotel system is activated from any
zone, this control signal goes to +5V. When the total system
Connect all sources to the first RMZ-955 per the instructions as
shown Installation: RMZ-955 Controller on page 6.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION: MULTI-CONTROLLER SYSTEMS
Then, using standard shielded RCA-RCA audio interconnet
cables, connect Source 1’s “loop through” outputs on the first
RMZ-955 “A” to the corresponding Source 1 inputs on the sec-
ond RMZ-955 “B”. Repeat this procedure for all four sources.
Use the following connections for multiple RMZ-955 systems:
For 2 RMZ-955s (5 to 8 zones):
• Remove the jumper between terminals 2 & 3 of the TX FORMAT
block on RMZ-955 “B” to disable its IR flood emitter. Leave the
jumper in place on RMZ-955 “A” if you are using its front-panel flood
emitter. Remove the jumper if you are using remote IR emiiters con-
nected to the back panel of RMZ-955 “A”.
If a system requires a third RMZ-955, repeat this procedure but,
this time, connect the “loop-though” source output on the sec-
ond RMZ-955 “B” to the corresponding input on the third
RMZ-955 “C” and so for a fourth controller “D”.
• Link IR signals to the first controller by connecting terminal 3 of
the RMZ-955 “B” TX FORMAT block to terminal 4 on RMZ-955
“A”. This completes the IR signal link to the IR flood or “remote”
emitter on RMZ-955 “A”.
NOTE: It is important to observe proper channel continuity when
connecting source components to more than one RMZ-955.
RMZ-955
"A"
RMZ-955
"B"
IR Connections
TX-FORMAT
1 2 3 4 5 6
TX-FORMAT
1 2 3 4 5 6
Systems with multiple RMZ-955 controllers follow generally the
same approach to distributing IR signals to the source compo-
nents as a single RMZ-955 system. Therefore, review the section
on IR installation, particularly on the choice of using the front-
panel flood emitter or the back-panel “remote” emitter connec-
tions.
Use this jumper arrangement with 3 RMZ-955 controllers.
Disables the IR flood emitters on all but the first controller.
Remove gray jumper if using back panel IR repeaters
from the first RMZ-955 instead of the flood emitter.
When 2 or more RMZ-955s are used in the same system, we sug-
gest that you connect them so that only the first RMZ-955 distrib-
utes IR commands to the source components and that the IR
emitter functions of all additional RMZ-955 controllers is dis-
abled. This avoids potential interference leading to erratic
operation, particularly when using the front panel IR flood emit-
ters.
For 3 RMZ-955s (9-12 zones):
• Remove the jumpers between terminals 2 and 3 of the TX FOR-
MAT blocks on RMZ-955 “B” and “C” to disable their flood emit-
ters. Leave the jumper in place on the first RMZ-955 “A” to use
its front-panel flood emitter. Remove this jumper as well do dis-
able the flood emitter when using remote IR emitters.
Note: This is a suggestion only and not a hard and fast rule.
There may be some unusual system layouts which benefit from
multiple RMZ-955s distributing IR to the sources. This option is
covered below as an exception to the standard practice.
• Connect terminal 3 of the RMZ-955 “C” TX FORMAT block to
terminal 4 on RMZ-955 “B”.
• Connect terminal 3 of the RMZ-955 “B” TX FORMAT block to
terminal 4 on RMZ-955 “C”. This completes the signal link to the
IR flood emitter on RMZ-955 “A” from the other two RMZ-955s.
The general approach to configuring IR connections for multi-
controller systems involves three steps:
RMZ-955
"A"
RMZ-955
"B"
RMZ-955
"C"
a) Configure the first RMZ-955 “A” to distribute IR codes to the
sources (either through its front-panel flood emitter or its “re-
mote” IR emitters as described in the section on installing single
controller systems.
TX-FORMAT
1 2 3 4 5 6
TX-FORMAT
1 2 3 4 5 6
TX-FORMAT
1 2 3 4 5 6
b) Disable the flood emitter on all other RMZ-955 controllers by re-
moving the “TX-Form” jumper connecting Pins 2 and 3.
Use this jumper arrangement with 3 RMZ-955 controllers.
Disables the IR flood emitters on all but the first controller.
Remove gray jumper if using back panel IR repeaters
from the first RMZ-955 instead of the flood emitter.
c) Relay IR codes from additional RMZ-955 controllers to the first
one by installing a series of jumper wires connected to the “TX-
Form” terminal block as outlined below.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-ROOM SYSTEM CONTROLLER RMZ-955
For example, the gray jumper wire in the following illustration is
used to activate the front-panel flood emitter on RMZ-955 “B” in
addition to “A”.
For 4 RMZ-955s (13-16 zones):
• Remove the jumpers between terminals 2 and 3 of the TX FOR-
MAT blocks on RMZ-955 “B” and “C” and “D” to disable their
flood emitters. Leave the jumper in place on the first RMZ-955
“A” to use its front-panel flood emitter. Remove this jumper to
disable the flood emitter when using back panel IR repeaters.
RMZ-955
"A"
RMZ-955
"B"
RMZ-955
"C"
RMZ-955
"D"
TX-FORMAT
1 2 3 4 5 6
TX-FORMAT
1 2 3 4 5 6
TX-FORMAT
1 2 3 4 5 6
TX-FORMAT
1 2 3 4 5 6
• Connect terminal 3 of the RMZ-955 “D” TX FORMAT block to
terminal 4 on RMZ-955 “C”.
• Connect terminal 3 of the RMZ-955 “C” TX FORMAT block to
terminal 4 on RMZ-955 “B”.
Use this jumper arrangement to enable the front
panel IR flood emitters on the first two RMZ-955s.
• Connect terminal 3 of the RMZ-955 “B” TX FORMAT block to
terminal 4 on RMZ-955 “C”. This completes the signal link to the
IR flood emitter on RMZ-955 “A” from the other two RMZ-955s.
Here, the gray jumper wire is used to activate the flood emitter
on all four RMZ-955 controllers:
RMZ-955
"A"
RMZ-955
"B"
RMZ-955
"C"
RMZ-955
"D"
RMZ-955
"A"
RMZ-955
"B"
RMZ-955
"C"
RMZ-955
"D"
TX-FORMAT
1 2 3 4 5 6
TX-FORMAT
1 2 3 4 5 6
TX-FORMAT
1 2 3 4 5 6
TX-FORMAT
1 2 3 4 5 6
TX-FORMAT
1 2 3 4 5 6
TX-FORMAT
1 2 3 4 5 6
TX-FORMAT
1 2 3 4 5 6
TX-FORMAT
1 2 3 4 5 6
Use this jumper arrangement with 4 RMZ-955 controllers.
Disables the IR flood emitters on all but the first controller.
Remove gray jumper if using back panel IR repeaters
from the first RMZ-955 instead of the flood emitter.
Use this jumper arrangement to enable the front
panel IR flood emitters on all four RMZ-955s.
Paging Connections
Exception: Multiple IR Flood Emitters
When using the Paging feature in a multi-controller system, two
additional installation steps are required. See page 11 for an
overview of the paging feature.
As stated above, the general practice is to send IR commands to
the source components from only the first RMZ-955 and to dis-
able the flood emitters on all other RMZ-955 controllers. The pur-
pose of this rule is to prevent IR signals from two different flood
emitters interfering with each other and confusing the source
component.
a) To trigger the muting and/or paging function, it is necessary to
connect the Paging Trigger input to all RMZ-955 controllers. This
requires making multiple connections from whatever device or
mechanism is used to supply a shorting input.
An exception to this general rule might arise in systems where
some source components are housed in one closed cabinet and
others in a different closed cabinet. In this case, you may wish to
use two or more RMZ-955 controllers, one in each cabinet, to
distribute the IR signals from their flood emitters to the source
components.
b) For announcements to be heard in all zones connected to all
RMZ-955s, the paging audio signal must be distributed to all con-
trollers. This can be done by connecting the Paging Audio Output
on the first RMZ-955 to the Paging Audio Input on the second
RMZ-955, using a standard RCA to RCA interconnect cable. Re-
peat this connection from the second to the third controller and
from the third to the fourth, if necessary.
This can be accomplished with a jumper wire from Terminal 2 of
the first RMZ-955’s TX-Form block to Terminal 2 on any other
RMZ-955 that needs to have its front-panel flood emitter acti-
vated.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION: MULTI-CONTROLLER SYSTEMS
Notes on multi-controller set-up
Power Toggle Set-up
We recommend in systems with multiple RMZ-955 controllers
(with full AC control from any Zone) that you select source com-
ponents that do not require a “power toggle” command, i.e. com-
ponents that fully power up when AC power is applied, instead of
going into a standby mode.
If sources requiring a “power toggle” command are used, only
one RMZ-955 controller should have the “power toggle” feature
activated (i.e. set to “y” during setup). Make sure that the
“Power Toggle” command is DEACTIVATED for all other
RMZ-955(s).
Even though the default “Power Toggle” setting is OFF, verify that
this has not changed by temporarily connecting an RSM-901 to
the Zone A data terminal of each remaining RMZ-955, entering
Set-up Mode as outlined and pressing the RLC-900 “n” (for No)
key. Continue to hold the “n” key and press the other set-up key
“y” to exit setup.
This is a critical step in a system using multiple RMZ-955s. If
the “Power Toggle” is not deactivated for the additional
RMZ-955(s), source components will not turn on and off properly
— in fact, source components may actually turn off when
RMZ-955s turn on.
Source Component Set-up
Programming of command code sets for source components is
covered in the following section of the manual. However, keep in
mind that in systems with multiple RMZ-955 controllers, it will be
necessary to reprogram these codes for each RMZ-955 in the
system. This must be done from an RSM-901 sensor display con-
nected to Zone A on each controller.
“Engaged” Indicator
The “Engaged” indicator on a remote zone’s RSM-901 sensor/
display(s) will indicate other same-source users only in zones
connected to that particular RMZ-955 controller/amplifier.
For example, in an 8-zone system using two RMZ-955s, a CD lis-
tener in Zone 7 (connected to the second RMZ-955) would have
no indication that another user in Zone 2 (connected to the first
RMZ-955) was listening to the same source. If a third listener in
Zone 4 then selected CD, only the listeners in Zones 2 and 4 (both
connected to the same RMZ-955) would know that someone else
was sharing the same source.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-ROOM SYSTEM CONTROLLER RMZ-955
b) Select an input (Tuner, CD, Tape/Sat, or VCR/DVD) on the RR-952
System Set-up & Programming
so that the corresponding label shows on Zone A’s RSM-901 sen-
sor/display.
c) Place the Set-up Card over the RR-952’s pushbuttons.
Source Commands
d) With the RR-952 pointing at the RSM-901 sensor/display, enter
“Set-up” mode by pushing both Set-up buttons simultaneously
for a few seconds until the RSM-901 displays “Set ?”, indicating
that the system is awaiting further instructions.
The RMZ-955 is factory set for use with Rotel source components,
including Rotel multi-disc CD players. No adjustments are neces-
sary for these components.
In addition to Rotel source components, the RMZ-955 can be set
to operate the following:
Input 1 Tuners:
Input 2 CD:
Rotel, Sony, Pioneer, Yamaha, Denon
Rotel, Sony, Pioneer, Yamaha, Denon, RC5
Input 3 Tape Deck: Rotel, Sony, Pioneer, Yamaha, Denon
Satellite TV: RCA, Sony
Input 4 CD 2:
Sony, Pioneer
Laser Disc: Pioneer
VCR:
Sony, Panasonic
DVD Player: Pioneer, Toshiba
Note 1: Assign each type of component to the input specified
above so that the label displayed by the RSM-901 (Tuner, CD,
etc.) matches the component when each input is selected.
Note 2: Two CD players of the same brand cannot be used in the
same system. Chose a different brand for CD.2
TA
VID
VOL
VOL
Source Command Set-up
MUTE
a) Locate Zone A’s RSM-901 sensor/display. Source command sets
cannot be changed from any other Zone or even from Zone A’s
keypad. If in doubt, send a command with the RR-952 hand held
remote and monitor Zone A’s green Code LED on the RMZ-955’s
front panel: it will flash when the RMZ-955 recognizes and
processes a command.
RR-952
Note: Remember that any RSM-901 sensor/display can be con-
nected to the Zone A data terminal for this procedure. Even if
Zone A is equipped with a wall mounted sensor/display, it is
probably more convenient to temporarily disconnect the data
cable from that unit and substitute another RSM-901 placed near
the RMZ-955 and source components.
To avoid the possibility of an IR loop when using an RSM-901 lo-
cated near the RMZ-955, temporarily remove the jumper be-
tween Terminals 2 and 3 of the TX FORMAT terminal block on the
rear panel of the RMZ-955. Also make sure that any RSM-901
used in this set-up sequence has the circuit board DIP switches
set for Zone A and “Master” (See page 13).
24
Download from Www.Somanuals.com. All Manuals Search And Download.
SYSTEM SET-UP & PROGRAMMING
e) Push the desired command code button for the component you
want to change. The available choices for that input are grouped
together on the Set Up Card. Upon receiving your selection, the
RSM-901 will display one of the following characters to indicate
your choice of custom command sets:
Power Toggle
If you choose to power source components from the RMZ-955’s
Switched AC outlet and your system includes components which
normally power on in a standby mode, you will need to ACTIVATE
the RMZ-955’s software-based “Power Toggle” command.
A
B
C
D
E
Rotel Tuner
Rotel CD Changer RCC-945
Pioneer LD/DVD
Rotel Tape Deck
Sony Tuner
The “Power Toggle” command fully activates these components
even though they usually go into a quiescent or Standby mode
when first plugged into the wall or when AC power becomes
available.
F
Sony CD
G
H
I
Sony CD 2
Sony Tape Deck
Pioneer Tuner
Pioneer CD
Source components connected through a switched outlet or the
RLC-900 are totally disconnected from AC when the outlets are
switched off. Consequently, when the RMZ-955 first activates the
source components, some go into a “standby” mode where a
few sensors and microprocessors are powered but where major
circuitry blocks are still inactive. The “Power Toggle” command
tells the sensors and microprocessors to “wake up” the rest of
the component.
J
K
L
Pioneer CD 2
Pioneer Tape Deck
Yamaha Tuner
Yamaha CD
Panasonic VCR
Yamaha Tape Deck
Denon CD
Sony VCR
Denon Tape Deck
Denon Tuner
M
N
O
P
Q
R
S
T
The following steps will illustrate how the “Power Toggle” com-
mand works:
• RMZ-955 in “Standby” mode, source components OFF.
U
V
W
X
Rotel CD Changer RCC-935
RCA DSS Sat TV
Toshiba DVD
• Zone activation command received. RMZ-955 ON, Switched AC
outlet activated, source components switched ON or to
“Standby” mode.
Sony DSS Sat TV
f) Repeat the above procedure for the other inputs. After you’ve se-
lected the command codes for all the component categories you
wish to change, exit “Set-up” by holding the right-hand SET-UP 2
button and pushing the left-hand SET-UP 1 button. The word
“SAVE” will appear on the RSM-901 display to indicate that the
new configuration has been memorized.
• RMZ-955 sends “Power Toggle” command to source compo-
nents. “Power Toggle” triggers change from “Standby” to “On”.
• All source components ready for remote zone use.
The “Power Toggle” command default is OFF but it can be easily
activated. “Power Toggle” is activated or deactivated depending
on which of the two SET-UP bottons is pressed first when exiting
the Set-up Mode. Press the “y” (for Yes) key first to activate
“Power Toggle”. Continue holding the “y” key and press the “n”
key to exit Set-up. This activates the RMZ-955’s software-based
“Power Toggle” command.
g) For the new command sets to take effect, the RMZ-955 must be
turned OFF (using the front panel power button) and then turned
ON again after 30 seconds.
All changes are stored in non-volatile memory and can not be
accidentally erased, even by unplugging the RMZ-955. The only
way to change command code operation is to access Set-up
mode again.
If source components are powered directly from an AC wall out-
let, make sure the “Power Toggle” command is DEACTIVATED
(the RMZ-955’s default condition) and that any source compo-
nents featuring a “Standby” mode are “ON” before using the
RMZ-955. To deactivate “Power Toggle”, press and hold the “n”
key first. Then, press the “y” key to exit Set-up.
Note: See Page 5 for further details on the “Power Toggle” com-
mand required when the RMZ-955 system (and associated
source components) use the switched outlet or recommended
RLC-900 Power Line Conditioner as an AC power source.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-ROOM SYSTEM CONTROLLER RMZ-955
Operating Instructions
RR-952 Hand-held Remote
As detailed in above, the RMZ-955 should ALWAYS be plugged
into an uninterruptable AC source. This ensures that essential
RMZ-955 system benefits such as remote controlled zone activa-
tion and source selection are always available. Zone control de-
vices (the RKP-901 keypad and RSM-901 sensor/display) are
powered from the data cables and are always active as long as
the RMZ-955 is connected to AC.
The RR-952 remote provides easy and convenient system opera-
tion from any zone equipped with a RSM-901 sensor/display. You
will find that the RR-952/RSM-901’s operating range is longer and
the angle of acceptance is wider than with many other hand held
controllers. This increased operating convenience is a direct re-
sult of a more powerful transmitter in the remote and more sensi-
tive receiving circuitry in the sensor/displays. Enjoy the
difference.
To use the RR-952 remote control, simply aim it at a wall-
mounted RSM-901 sensor/display.
Input Selector Buttons
These buttons provide “one-touch” operation of the system,
playing the selected source component in the requesting zone.
The actual function of the buttons depends on the current sys-
tem status, but the net effect is the same: activate the system (if
necessary), select the desired component, put it in play mode (if
necessary), and direct its signal to the local zone.
INPUT
BUTTONS
Depending on system status, pressing any of these buttons will
do one of the following:
TUNER
TUNER
CD
FAV STN
STOP
–
PRESETS +
SKIP
BUTTONS
a) If the entire system is “Off” (i.e., the RMZ-955 is in “Standby”
mode and all source components are either Off or in “Standby” ),
pressing any input selector button will activate the entire system
(including source components) for distribution as requested.
CD
BUTTONS
RANDOM
DISC
TAPE / SAT
BUTTONS
b) If only the requesting zone is in “Standby” (and the rest of the
system, including sources, is active), selecting an input will en-
able that zone’s microprocessor-controlled switching circuitry
and direct that source’s output to the requesting zone. If the re-
quested source is not already in use by another zone, selecting
the source will also engage Play mode.
TAPE/SAT
VIDEO/LD
STOP
STOP
VIDEO / LD
BUTTONS
PAUSE
–
CHNL
+
c) If the requesting zone is already playing a source, pushing an-
other input selector button will simply choose the new source.
VOL
VOL
STBY
X
d) Input selector buttons for CD, TAPE and VIDEO double as “Play”
command buttons for their respective sources. This is important
when a source is in “Pause” mode: Simply press the proper input
selector again to resume play.
MUTE
Tuner control buttons
RR-952
FAV STN (Favorite Station): This will select the first station (Pre-
set #1) programmed into the tuner’s memory.
– PRESET + : These select the next PRE-PROGRAMMED station
lower or higher in frequency than the one playing.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING INSTRUCTIONS
CD control buttons
Mute
RANDOM: This instructs the CD player to play tracks (and discs
for multi-disc changer) in whatever random order the CD player
chooses.
This temporarily reduces zone volume to very quiet levels for
telephone conversations, etc. Press Mute again to restore origi-
nal volume settings. You can also press Volume Up, Volume
Down or any Input button to restore original levels.
DISC: This advances the CD player to the next available disc.
(functional only with multi-play CD players)
VOLUME UP/VOLUME DOWN
SKIP
: These advance the CD player to the next track,
Nothing surprising here – simply press the appropriate button to
increase or decrease playback levels as desired.
backward or forward , on the disc being played.
STOP: This stops the CD player. Press the CD button to resume
playing.
STBY
This button has two functions:
Tape/Satellite TV control buttons
a) A brief push will put the Zone from which the command originated
into Standby status. All other zones will remain unaffected. Source
components will remain on.
STOP: This button stops tape. Press the TAPE/SAT button to re-
sume playing.
b) A continuous push (more than 4 seconds) performs a total sys-
(Rewind): This rewinds the tape. Press the TAPE input se-
lect pushbutton to put the deck back into PLAY mode again. For
tem-wide “power down”.
Satellite TV, this changes to the next lower channel.
This system “power down” includes deactivating all zones, shut-
ting off AC power to all components connected to the RMZ-955’s
switched AC outlets, and putting all RMZ-955’s in standby mode.
(Fast forward): Same as above but in the opposite direction.
For Satellite TV, this changes to the next higher channel.
Video/LD control buttons
“X”
STOP: Stops the video tape or disc. Press the VIDEO/LD button to
resume playing.
Reserved for future use and inoperative at the present time.
PAUSE: This button momentarily stops disc play until it is pushed
again.
Note: Should you need more advanced IR controls for a particu-
lar source, you may be able to use the source’s own dedicated IR
remote control. In most cases, the RSM-901 and the IR repeater
system will be able to pass IR codes directly to the source from
any remote control.
– CHNL : If a DVD disc is playing, this button backs up to the be-
ginning of that track and continues playing. Two quick pushes
backs the player to the beginning of the PREVIOUS track or
chapter. If a VCR is selected, this changes its tuner to the next
lower channel. If CD2 is playing, this button selects “Random
Play”
CHNL + : If a DVD is playing, this button goes forward to the be-
ginning of the next track. If a VCR is selected, this changes its
tuner to the next higher channel. If CD2 is playing, this button se-
lects the next disc.
(Reverse Scan): This begins a high speed reverse scan use-
ful for returning to a desired point in a movie, etc. Press the
VIDEO/LD input selector button to go back to Play mode when
you’ve reached the desired point on the disc. If CD2 is playing,
this button skips to the beginning of the current track.
(Forward Scan): The same as above but in the opposite (i.e.,
forward) direction.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-ROOM SYSTEM CONTROLLER RMZ-955
you hear a different source, sending a Play command if neces-
sary. Finally, the Input Select button can be used as a Play button
to resume operation following a previous Pause command.
RKP-901 Keypad
The details are not important. If you want to hear a source in your
room, just press the Input Select button for that source and the
system will worry about the details for you.
TUNER: Selects the tuner as the active source.
CD
TUNER
VIDEO
CD: Selects the CD player as the active source and sends the play
AUX
command to begin operation, if necessary.
AUX: Selects the source component connected to Input 3 (tape
deck, or satellite TV) as the active source and sends the play
command to begin operation, if necessary.
VOLUME
DISC
OFF
*
MUTE
VIDEO: Selects the video component (VCR, CD2, or DVD) as the
active source and sends the play command, if necessary.
System commands
– VOLUME + : Press to decrease or increase volume.
The RKP-901 keypad offers easy access to most RMZ-955 system
functions. The major functional difference between the RKP-901
keypad and RR-952 hand held remote controller is that the wall-
mounted keypad has only twelve keys.
MUTE: Temporarily reduces system volume to almost full attenua-
tion. Restore preselected volume levels by pressing MUTE again,
VOL+, VOL– or any input selector.
OFF: A brief push puts the Zone from which the command is sent
in Standby status. All other zones are unaffected. A continuous
push of more than 4 seconds will send a stop command to all
source components and power down the entire system.
Input Select commands
These buttons provide “one-touch” operation. If the system is cur-
rently inactive, pushing any of the four input source selection but-
tons will “power up” the RMZ-955’s and the source components,
send the play command to the selected source, and send the sig-
nal from that source to the zone from which the button is pushed.
Assuming the tuner is tuned to a station, a disc in the CD player,
etc., you will hear music with the push of a single button.
Source Control Commands
and : These buttons are “up” and “down” controls for operat-
ing source components. Their function varies depending on the
type of source currently active. See chart below.
The function of the button changes slightly if the system is already
active. For example, if the source selected is already playing in
another zone, pushing the Input Select button will not send a Play
command, but will simply let you hear what is already playing. If
your zone is already active, pressing an Input Select button lets
DISC: This advances a multi-disc CD player to the next available
disc. This button has no function for other components.
: This button is a multi-purpose control, depending on the cur-
rently active source component. For most source components, it
*
will send the STOP command to the source. However, it may also
be used for a special function on some components. See chart.
DISC
*
Track skip (back)
Preset –
Track skip (forward)
Random/Shuffle Play
Favorite Station
Stop
CD PLAYER
TUNER
Next Disc
Preset –
No function
No function
No function
No function
No function
No function
No function
Chapter Skip (back)
Track Skip (back)
F. Rewind/Scan
Skip Back
Chapter Skip (forward)
Track Skip (forward)
F. Forward/Scan
Skip Forward
VIDEO (LD)
VIDEO (CD2)
VIDEO (VCR)
VIDEO (DVD)
AUX (TAPE)
AUX (SAT)
Random/Shuffle Play
Stop
Stop
Rewind
Fast Forward
Stop
Channel (down)
Channel (up)
No function
28
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING INSTRUCTIONS
Dot Matrix Display
RSM-901 Sensor/Display
The dot matrix display shows the following status information:
The RSM-901 sensor/display receives IR signals from the RR-952
hand held controller and other IR devices. It also provides feed-
back on system status through a dot matrix LED display and indi-
cators. In addition, it provides convenience features including a
time of day display and a “wake to music” alarm clock function.
Clock Display and Greeting: When the Zone is INACTIVE, the
display shows the current time of day in a 4-digit 12-hour format.
When the Zone is first activated, a time-appropriate greeting will
display momentarily, followed by a display of the selected source
component. To check the time while the Zone is ACTIVE, press
the MODE button.
Note: The RSM-901 passes remote control IR commands to the
RMZ-955 controller at any time, regardless of whether its zone is
currently active or not.
Source Selected: When the Zone is ACTIVE, the display shows
the selected source component:
RECEIVE
RECEIVE
LED
Tuner
Tape Deck
VCR
CD Player
Satellite TV
DVD Player
DOT
MATRIX
DISPLAY
PM LED
MODE
HOUR
MIN
MODE
BUTTON
HOUR
BUTTON
MINUTE
BUTTON
PM
ALARM
ALARM
LED
Controls and Displays
Dot Matrix Display: Shows a variety of system and zone status
information, including time of day (when the zone is inactive) and
source component selection (when the zone is active).
Engaged Indicator: It is useful to know when someone in another
Zone is listening to the same source component that is active in
your zone. If your Zone has exclusive use of the active source,
the Source indicator’s first character will be a capital letter. If
the source is “engaged” or being shared with another zone, the
first character will change to lower case.
RECEIVE LED: Flashes when the RSM-901 receives an IR control
code from the RR-952 handheld remote or RKP-901 keypad.
PM LED: Lights up when the 12 hour clock time is after 12 noon
and before 12 midnight.
ALARM LED: Lights to show that the “wake to music” alarm has
been set and will execute at the set time, activating ONLY the
Zone from which is has been set, not the whole system. If this
LED is not lit, no alarm is in effect.
Exclusive use
of source
Source engaged
in another zone
MODE Button: Used to set and activate various RSM-901 func-
tions, including setting the time, setting the alarm, etc.
HOUR Button: Used in conjunction with the MODE button to set
up the RSM-901. It has no function when the Zone is active.
MIN Button: Used in conjunction with the MODE button to set up
the RSM-901. It has no function when the Zone is active.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-ROOM SYSTEM CONTROLLER RMZ-955
Volume Level: When the Volume setting is changed in the Zone,
the RSM-901 will momentarily display the new setting:
a) Turning Alarm ON or OFF:
Press the MIN button to activate the wake-up alarm. Press the
HOUR button to deactivate. The ALARM LED reminds you that the
alarm has been activated. When finished, press the MODE but-
ton to record your changes and advance to the next step.
RECEIVE
Minimum Volume
Maximum Volume
When a MUTE signal is sent, the volume display will ramp down
to zero and show the message “MUTE”. When the Zone is un-
muted, the display will ramp up to its previous level.
MODE
PM
HOUR
ALARM
OFF
ALARM
MIN
ALARM
ON
If a Paging signal is received, the display will ramp down to zero
and show a “(())” message during the page. If the Zone is muted,
the Paging indicator will show immediately. If the Zone is in
standby, the Paging indicator will be preceded by the turn-on
greeting.
b) Setting Alarm Time:
The display will show the last alarm time set. Use the HOUR and
MINUTE buttons to advance to the desired Alarm time. Make
sure that the PM indicator shows the desired 12 hour period for
the alarm. When finished, press the MODE button to record your
changes and advance to the next step.
Muting Indicator
Paging Indicator
RECEIVE
Setting Alarm, Time, and Custom Functions
The following custom functions are programmed from the
RSM-901’s Set-Up mode:
MODE
PM
HOUR
HOUR
BUTTON
ALARM
• Activating Wake-up Alarm
MIN
MINUTE
BUTTON
• Setting Alarm Time
• Setting default source that plays when Alarm activates
• Setting Time of Day
To enter the Set-Up mode, press the MODE button when the
Zone is in stand-by mode (clock display showing). Continuing to
press the MODE button will toggle through the four set-up
choices above and then back to the standby mode.
After the first function has been selected, the RSM-901 will auto-
matically exit the Set-Up mode and return to stand-by status if no
button is pressed for approximately 10 seconds. Any changes
made to the set-up configuration will be stored.
To set the alarm and time, press the MODE button to step
through the following procedure. The diagrams show momentary
indications of the functions being set prior to their status being
shown.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING INSTRUCTIONS
c) Select the Default Source:
Select the source component that you want to begin playing
when the alarm goes off. Press the HOUR button to select the
TUNER. Press the MINUTE button to select the CD (make sure
there is a disc in the player). When finished, press the MODE
button to record your changes and advance to the next step.
For Assistance
We hope this manual has been of assistance in planning and in-
stalling your multi-room sound distribution system. Although
we’ve gone to great lengths to make this as complete as pos-
sible, we’re sure we haven’t covered every aspect of every pos-
sible system installation. Please feel free to contact our
Technical Support department if you have any questions.
RECEIVE
Rotel of America
54 Concord Street
North Reading, MA 01864-2699
Phone: 978-664-3820
Fax: 978-664-4109
MODE
PM
HOUR
TUNER
CD
ALARM
MIN
In addition, your local Rotel Authorized retailer is an invaluable
source of information and assistance, particularly in the area of
custom audio systems.
d) Setting Clock Time:
Thank you very much for purchasing a Rotel system.
The display will show the current time of day. Use the HOUR and
MINUTE buttons to make any changes. Make sure that the PM
indicator shows the correct 12 hour period. When finished, press
the MODE button to record changes and exit the Set-Up mode.
RECEIVE
MODE
PM
HOUR
HOUR
BUTTON
ALARM
MIN
MINUTE
BUTTON
Note 1:
The clocks in different zones may be slightly out of synch due to
drift or inaccurate setting. They will be re-synchronized auto-
matically with the master system clock in Zone A at 12 noon
each day .
Note 2:
If a RSM-901 is set as a SLAVE (see Page 13), only the clock can
be set. Only one alarm in each zone is permitted and it must be
set from the MASTER RSM-901 in each zone.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
RMZ-955
MULTI-ROOM SYSTEM
The Rotel Co., Ltd.
10-10 Shinsen-Cho
Meguro-Ku
Tokyo 150, Japan
Phone: +81-3-5458-5325
Fax: +81-3-5458-5310
Rotel of America
54 Concord Street
North Reading, MA 01864-2699
Phone: 978-664-3820
Fax: 978-664-4109
Rotel Deutschland
Kleine Heide 12
D-33790 Halle/Westf., Germany
Phone: 05201-87170
Fax: 05201-73370
Printed in the USA. RTL-02-98-026