Electric Dryer
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
DOOR CLEARANCE DIMENSIONS
3-7/8"
RES7646J
RES7646K
RES7648E
RES7648J
RES7648K
REX3614J
REX3614K
REX3615E
REX4625E
REX4634J
REX4634K
REX4635E
REX5634J
REX5634K
REX5635E
22-3/4"
terminal
block cover
19-1/8"
power supply
cord/cable
opening
22-3/4"
Super-large
14-1/2"
side-swing door (reversible)
42-3/8"*
Electrical: A four-wire or three-wire, single phase,
120/240-volt, 60-Hz, AC-only, electrical supply is
required on a separate 30-ampere circuit, fused on
both sides of the line. Use 10 gauge solid copper
wire. A time-delay fuse or circuit breaker is
recommended.
Exhaust venting: Exhaust your dryer to the
outside. Four-inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do Not
use plastic or metal foil vent. Exhaust outlet hood
must be at least 12 inches from the ground or any
object that may be in the path of the exhaust.
7"
6"*
22-3/4"
dryer exhaust
vent
17-3/4"
28" max.
29"
22-3/4"
*from floor with dryer
feet extended 1 inch
Large side-swing
door (reversible)
8-1/4"
15-1/4"
RECESSED AREA AND CLOSET INSTALLATION
Recommended/Minimum
Closet confined area
Back Sides
5"/0" 1"/0"
5"/4" 1"/0"
Top
18"/18"
Front
—
18"/18" 1"/1"
If a closet door is installed: The minimum unobstructed air
openings are required. Louvered doors with equivalent air
openings are acceptable.
Recessed
Closet
15-1/4"
front view
front view
side view
3"
15-1/4"
Small side-swing door
14"
48 sq. in.**
max.
closet
door
8-3/4"
25-5/8"
Recessed
area
18"
4"***
24 sq. in.**
13-3/4"
3"
1"
0" *
0" *
13-3/4"
Extra-large hamper door
** Minimum top and bottom air openings for closet door.
*** External exhaust elbow requires additional space.
*Wall, door and floor molding may require
additional spacing.
EXHAUST VENTING
Preferred
Acceptable
Select the route that will provide the straightest and most direct path
outdoors. Plan the installation to use the fewest number of elbows and
turns. Avoid making 90° turns.
When using elbows or making turns, allow as much room as possible.
Bend flexible metal vent gradually to avoid kinking.
4"
4"
2-1/2"
Determine vent length
When you have a 4" hood
When you have a 2-1/2" hood
1. See the exhaust vent length chart that matches your type hood for the
maximum vent lengths you can use.
Maximum length of 4"
diameter metal vent
Maximum length of 4"
diameter metal vent
Do not use vent runs longer than specified in exhaust vent length charts.
2. Determine the number of elbows you will need.
3. In the column listing the type of metal vent you are using (rigid or
flexible), find the maximum length of metal vent on the same line as the
number of elbows.
Number of
90° elbows
Rigid
Flexible
Number of
90° elbows
Rigid
Flexible
(fully extended)
(fully extended)
0
1
2
3
4
64 ft.
54 ft.
44 ft.
35 ft.
27 ft.
36 ft.
31 ft.
27 ft.
25 ft.
23 ft.
0
1
2
3
4
58 ft.
48 ft.
38 ft.
29 ft.
21 ft.
28 ft.
23 ft.
19 ft.
17 ft.
15 ft.
The maximum length using a 2" x 6" rectangular vent with 2 elbows and
a 2-1/2" exhaust hood is 8 ft.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 3397618
01-09-03
Download from Www.Somanuals.com. All Manuals Search And Download.
|