201a
Before using this unit, carefully read the sections entitled: “USING THE UNIT SAFELY” (p. 2)
and “IMPORTANT NOTES” (p. 4). These sections provide important information concerning
the proper operation of the unit. Additionally, in order to feel assured that you have gained a
good grasp of every feature provided by your new unit, Owner’s Manual should be read in its
entirety. The manual should be saved and kept on hand as a convenient reference.
202
Copyright © 2007 ROLAND CORPORATION
All rights reserved. No part of this publication may be reproduced in any form without the
written permission of ROLAND CORPORATION.
Download from Www.Somanuals.com. All Manuals Search And Download.
101b
107d
111: Selection
•
The unit and the AC adaptor
•
Never handle the AC adaptor
•
If used improperly, batteries
should be located so their
location or position does not
interfere with their proper venti-
lation.
body, or its output plugs, with
wet hands when plugging into,
or unplugging from, an outlet or
this unit.
may explode or leak and cause
damage or injury. In the interest
of safety, please read and
observe the following precau-
tions (p. 11).
.......................................................................
......................................................................
102d
108b
1
2
•
Always grasp only the output
plug or the body of the AC
adaptor when plugging into, or
unplugging from, this unit or an
outlet.
•
Before moving the unit,
disconnect the AC adaptor and
all cords coming from external
devices.
• Carefully follow the instal-
lation instructions for
batteries, and make sure you
observe the correct polarity.
......................................................................
109b
.......................................................................
• Avoid using new batteries
together with used ones. In addition,
avoid mixing different types of
batteries.
•
Before cleaning the unit, turn off
the power and unplug the AC
adaptor from the outlet (p. 13).
103b
•
At regular intervals, you should
unplug the AC adaptor and clean
it by using a dry cloth to wipe all
dust and other accumulations
away from its prongs. Also,
disconnect the power plug from
the power outlet whenever the
unit is to remain unused for an
extended period of time. Any
accumulation of dust between
the power plug and the power
outlet can result in poor
......................................................................
3
5
110b
• Remove the batteries whenever the
unit is to remain unused for an
extended period of time.
•
Whenever you suspect the possi-
bility of lightning in your area,
disconnect the AC adaptor from
the outlet.
• If a battery has leaked, use a soft piece
of cloth or paper towel to wipe all
remnants of the discharge from the
battery compartment. Then install new
batteries. To avoid inflammation of the
skin, make sure that none of the
battery discharge gets onto your hands
or skin. Exercise the utmost caution so
that none of the discharge gets near
your eyes. Immediately rinse the
......................................................................
112
•
Used batteries must be disposed
of in compliance with whatever
regulations for their safe disposal
that may be observed in the region in
which you live.
insulation and lead to fire.
.......................................................................
104
•
......................................................................
Try to prevent cords and cables
from becoming entangled. Also,
all cords and cables should be
placed so they are out of the
reach of children.
affected area with running water if any
of the discharge has entered the eyes.
6
.......................................................................
• Never keep batteries together with
metallic objects such as ballpoint pens,
necklaces, hairpins, etc.
106
•
Never climb on top of, nor place
heavy objects on the unit.
.......................................................................
.......................................................................
For EU Countries
SE
FI
UK
DE
HU
PL
FR
IT
CZ
SK
ES
PT
NL
EE
LT
LV
SI
DK
NO
GR
3
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT NOTES
291a
Maintenance
• For everyday cleaning wipe the unit with a soft, dry cloth
In addition to the items listed under “USING THE UNIT
401a
SAFELY” on page 2, please read and observe the following:
or one that has been slightly dampened with water. To
remove stubborn dirt, use a cloth impregnated with a
mild, non-abrasive detergent. Afterwards, be sure to wipe
Power Supply: Use of
Batteries
the unit thoroughly with a soft, dry cloth.
402
• Never use benzine, thinners, alcohol or solvents of any
301
kind, to avoid the possibility of discoloration and/or
deformation.
• Do not connect this unit to same electrical outlet that is
being used by an electrical appliance that is controlled by
an inverter (such as a refrigerator, washing machine,
microwave oven, or air conditioner), or that contains a
motor. Depending on the way in which the electrical
appliance is used, power supply noise may cause this unit
to malfunction or may produce audible noise. If it is not
practical to use a separate electrical outlet, connect a
power supply noise filter between this unit and the
Repairs and Data
452
• Please be aware that all data contained in the unit’s
memory may be lost when the unit is sent for repairs.
Important data should always be backed up in another
MIDI device (e.g., a sequencer), or written down on paper
(when possible). During repairs, due care is taken to avoid
the loss of data. However, in certain cases (such as when
circuitry related to memory itself is out of order), we
regret that it may not be possible to restore the data, and
Roland assumes no liability concerning such loss of data.
electrical outlet.
302
• The AC adaptor will begin to generate heat after long
hours of consecutive use. This is normal, and is not a
cause for concern.
303a
• The use of an AC adaptor is recommended as the unit’s
power consumption is relatively high.
304a
Additional Precautions
• When installing or replacing batteries, always turn off the
551
power on this unit and disconnect any other devices you
may have connected. This way, you can prevent
• Please be aware that the contents of memory can be
irretrievably lost as a result of a malfunction, or the
improper operation of the unit. To protect yourself against
the risk of loosing important data, we recommend that
you periodically save a backup copy of important data
you have stored in the unit’s memory in another MIDI
malfunction and/or damage to speakers or other devices.
306b
• Batteries are supplied with the unit. The life of these
batteries may be limited, however, since their primary
purpose was to enable testing.
device (e.g., a sequencer).
307
552
• Before connecting this unit to other devices, turn off the
• Unfortunately, it may be impossible to restore the contents
power to all units. This will help prevent malfunctions
and/or damage to speakers or other devices.
of data that was stored in another MIDI device (e.g., a
sequencer) once it has been lost. Roland Corporation
assumes no liability concerning such loss of data.
553
Placement
• Use a reasonable amount of care when using the unit’s
buttons, sliders, or other controls; and when using its jacks
352a
• This device may interfere with radio and television
and connectors. Rough handling can lead to malfunctions.
reception. Do not use this device in the vicinity of such
554
• Never strike or apply strong pressure to the display.
receivers.
556
354a
• When connecting / disconnecting all cables, grasp the
• Do not expose the unit to direct sunlight, place it near
connector itself—never pull on the cable. This way you
will avoid causing shorts, or damage to the cable’s
devices that radiate heat, leave it inside an enclosed
vehicle, or otherwise subject it to temperature extremes.
internal elements.
Excessive heat can deform or discolor the unit.
558b
355b
• To avoid disturbing your neighbors, try to keep the unit’s
• When moved from one location to another where the
volume at reasonable levels (especially when it is late at
temperature and/or humidity is very different, water
droplets (condensation) may form inside the unit. Damage
or malfunction may result if you attempt to use the unit in
this condition. Therefore, before using the unit, you must
allow it to stand for several hours, until the condensation
night).
558c
• Since sound vibrations can be transmitted through floors
and walls to a greater degree than expected, take care not
to allow such sound to become a nuisance to neighbors,
has completely evaporated.
especially at night and when using headphones.
360
559a
• Depending on the material and temperature of the surface
• When you need to transport the unit, package it in the box
on which you place the unit, its rubber feet may discolor
or mar the surface.
(including padding) that it came in, if possible. Otherwise,
you will need to use equivalent packaging materials.
561
• Use only the specified expression pedal (Roland EV-5,
BOSS FV-500L or FV-500H; sold separately). By
connecting any other expression pedals, you risk causing
malfunction and/or damage to the unit.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction.............................................................................................7
Panel Descriptions...................................................................................................................................... 7
Display.............................................................................................................................................. 7
Rear Panel....................................................................................................................................... 10
(e.g., the VG-99)............................................................................................................................. 13
About the MODES.................................................................................................................................... 14
Standard Mode (p. 16).................................................................................................................. 14
Control Change Mode (p. 21)...................................................................................................... 14
Standard Mode......................................................................................16
Setting How Tones are Switched................................................................................................ 16
Using the Control Pedal and Expression Pedal Switch........................................................... 22
Controller Numbers of the Pedals.............................................................................................. 23
About the Patch Mode............................................................................................................................. 29
About the Patch............................................................................................................................. 29
Transmitting Control Change Messages............................................................................................... 30
Using the Expression Pedals ....................................................................................................... 30
Using the Control Pedals and Expression Pedal Switches...................................................... 30
Using the External Control Pedals and Expression Pedals..................................................... 31
The Controller Number of Each Pedal....................................................................................... 31
Transmitting Patch Data.......................................................................................................................... 32
Creating Patches ....................................................................................................................................... 33
Editing MIDI Streams................................................................................................................... 34
5
Download from Www.Somanuals.com. All Manuals Search And Download.
How to Copy MIDI Streams........................................................................................................ 39
How to Delete MIDI Streams ...................................................................................................... 40
Storing (Saving) Patches.......................................................................................................................... 44
Deleting Patches ....................................................................................................................................... 45
Reducing Battery Consumption (Economy Mode).................................................................. 46
Setting the [ ] [ ] Pedal Step Size ....................................................................................... 49
] Pedals to Make the Settings ................................................................... 48
Switching How the Pedal Indicators Light ............................................................................... 51
Battery Low!................................................................................................................................... 57
MIDI Buffer Full!........................................................................................................................... 57
RRC2 Offline!................................................................................................................................. 57
2. Address-mapped Data Transfer ............................................................................................. 59
2. Transmitted Data.................................................................................................................................. 62
Transmitted Messages.................................................................................................................. 62
3. Exclusive Communications................................................................................................................. 64
4. Parameter Address Map (Model ID = 00H 00H 20H)..................................................................... 64
Specifications........................................................................................68
FC-300 : MIDI FOOT CONTROLLER ................................................................................................... 68
Index.......................................................................................................69
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Main Features
• Features four modes (Standard Mode, Control Change Mode, System Exclusive
Mode, Patch Mode)
• Unit comes equipped with two expression pedals and two control pedals.
You can also expand control even further with up to three external expression
pedals or six external control pedals.
• Includes 16-character x 2-line LCD
• Equipped with RRC2 OUT connector; enables connection with RRC2 IN
compatible devices with a single cable
• Includes two separate amp control channels
• Features three-way power supply (AC Adaptor, Dry battery, RRC2)
Panel Descriptions
Display
1
3
2
1
2
3
MODE indicator
The current mode is indicated here. (p. 15)
BANK/NUMBER display
The currently selected bank and number are indicated here.
Liquid Crystal display (LCD)
A variety of information is shown in this display.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Top Panel (Buttons)
1
3
6
2
5
4
1
2
To jump to the main
PARAMETER button [
] [
]
parameters, hold down one of
these buttons while you press
the other. With items for which
there aren’t that many
parameters, the FC-300 jumps
to the last (or initial)
Press these to select parameters.
UTILITY button / INS (insert) button
Press this when changing system settings. In the Edit screen, this is used to insert
MIDI messages and blank spaces.
parameter.
3
MODE button / DEL (delete) button
Press this to change the FC-300’s operating mode. In the Edit screen, this is used to
delete a MIDI message or a character at the cursor location.
4
5
6
VALUE button [
] [
]
Use this when changing the values of settings.
• By continuing to hold down
VALUE for a number of
seconds, the value of the
setting can be increased/
decreased continuously.
• The value will increase
rapidly if you hold down
EXIT button
Press this to undo an operation and return to the previous screen.
WRITE button
VALUE [
], then press
].
Press this to store settings and execute procedures.
and hold VALUE [
• The value will decrease
rapidly if you hold down
VALUE [
], then press
].
and hold [
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Top Panel (Pedals)
1
[
] [
] (down / up) pedals
Use these pedals to switch banks and select numbers.
Additionally, you can switch modes by pressing the pedals simultaneously.
2
CTL (Control) pedals (1, 2)
You can assign the desired functions to these pedals, then use them for control over
those functions.
3
4
Number pedals (1/6 – 5/10)
These switch the patch numbers.
Number pedal indicators (1/6 – 5/10)
When you operate the
The indicator for the currently selected number lights.
expression pedal, please be
careful not to get your fingers
pinched between the movable
part and the panel. In
A red indicator lights when a number from 1 through 5 is selected; a green indicator
lights when a number from 6 through 10 is selected.
households with small
5
EXP PEDAL (expression pedal) (1, 2)
children, an adult should
provide supervision until the
child is capable of following all
the rules essential for the safe
operation of the unit.
These control the volume, wah, or other aspects of connected devices.
6
7
EXP PEDAL SW (expression pedal switch) (1, 2)
Firmly press down at the front of the pedal to switch the effect on and off.
EXP PEDAL SW indicators (expression pedal switch indicators) (1, 2)
Lights when the effect being controlled with the EXP PEDAL SW is on, and goes out
when the effect is turned off.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Rear Panel
3
4
6
7
8 9
2
5
1
1
Security Slot
2
MODE jack
Connect an optional footswitch (such as the BOSS FS-5U) here.
The function is the same as that when the [
simultaneously.
] and [
] pedals are held down
3
4
5
6
EXP PEDAL/CTL jack
Connect an optional expression pedal (such as the Roland EV-5, BOSS FV-500L/FV-
500H) or footswitch (such as the BOSS FS-5U/FS-6) here.
AMP CONTROL 1, 2 jack
When using the AMP CONTROL function, connect to the jack used for switching
guitar amp channels.
Be sure to connect the RRC2
OUT connector to a device
with an RRC2 IN connector.
Use of the connection with
other devices may cause
generation of heat and damage
to the equipment.
MIDI connectors (OUT, IN)
Connect an external MIDI device to these connectors to transmit and receive MIDI
messages.
When running on power
supplied by an RRC2 IN
device, the power is switched
on regardless of the position of
the POWER switch.
RRC2 OUT connector
You can connect an external RRC2 IN device here to transmit and receive
performance data between the devices.
At the same time, the FC-300 can be powered by the external RRC2 IN device.
7
8
RRC2 is a Roland standard
developed to enable two-way
communications between
RRC2 IN devices and RRC2
OUT devices, while supplying
power to the RRC2 OUT
POWER switch
Turns the power on and off.
DC IN (AC Adaptor) jack
device from the RRC2 IN
device, all with a single cable.
Connect the AC adaptor (PSA series; sold separately) here.
9
You must use only the PSA
series AC adaptor. Use of any
other adaptor may cause
Cord Hook
Hook the AC adaptor cord here to prevent the adaptor plug from being
disconnected. Refer to “Connecting an AC Adaptor” (p. 12).
overheating or malfunctions.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Making the Connections
921
When making connections to other equipment, be sure that all equipment is
switched off. If you try to make connections while the power is turned on, the
settings for the FC-300 may be changed.
Before connecting other
devices, always be sure to turn
down the volume on all
Connections To Make When Using the FC-300 as a
devices and turn off their
power to prevent malfunction
and damage to the speakers (or
other components) of
MIDI Foot Controller
fig.
AC Adaptor
BOSS PSA series
connected devices.
922
This instrument is equipped
with 1/4 inch TRS phone type
jacks. Wiring diagrams for
these jacks are shown below.
Make connections after first
checking the wiring diagrams
of other equipment you intend
PCS-31
PCS-31
White Red
White Red
Connect to footswitch jack
MIDI IN
MIDI OUT
BOSS
FS-5U
BOSS BOSS
FS-5U FS-5U
BOSS
FS-6
External Sound Module
EV-5 etc.
MIDI Sequencer etc.
to connect.
fig.XLR/TRSJack.eps
Guitar Amp etc.
If you want to use a footswitch for changing the mode, be sure to connect a BOSS FS-
5U/FS-6 footswitch (Optional) to the MODE jack.
When using the FS-5U or FS-6, set the polarity switch as shown below.
fig.FS-5U.eps
B
A
BOSS FS-6
BOSS FS-5U
928
Install batteries
The FC-300 is not loaded with batteries when purchased.
When running the FC-300 on battery power, install the batteries using the following figure.
fig.change-battery.eps
• When turning the unit
upside-down, get a bunch of
newspapers or magazines,
and place them under the
four corners or at both ends
to prevent damage to the
buttons and controls. Also,
you should try to orient the
unit so no buttons or
controls get damaged.
9•29When turning the unit
upside-down, handle with
care to avoid dropping it, or
allowing it to fall or tip over.
When the battery power
begins to run low, “Battery
Low!” appears in the display.
When this occurs, replace with
new batteries as soon as
possible.
Pressing [EXIT] clears the
message from the display.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Connecting an AC Adaptor
If you’re using a BOSS PSA series AC adaptor, here’s how to connect the cord and
secure it on the cord hook.
fig.CordHook.j.eps
The cord of
the supplied AC Adaptor
Cord Hook
To the Power Outlet
Connections To Make When Using the FC-300 as a
Dedicated Foot Controller for an RRC2 IN Device
(e.g., the VG-99)
fig.
925
RRC2 IN device
Use only the specified
expression pedal (Roland EV-
5, BOSS FV-500L/FV-500H;
each sold separately). By
connecting any other
RRC2 cable
expression pedals, you risk
causing malfunction and/or
damage to the unit.
PCS-31
PCS-31
White Red
White Red
Connect to footswitch jack
Carefully connect the RRC2
cable or Ether cable all the way
in—until it is firmly to the
RRC2 connector.
BOSS
FS-5U
BOSS BOSS
FS-5U FS-5U
BOSS
FS-6
EV-5 etc.
Guitar Amp etc.
* Power is supplied from the RRC2 IN device, so no batteries or AC adaptor is necessary.
* If using commercially available ethernet cable as the RRC2 connecting cable, be sure that
the cable meets the following specifications.
Ethernet cables designed for
crossover connections cannot
be used.
• Category 5 (Cat5) or above
• Maximum length of 15 meters
• Cable designed for straight-through connections
Do not subject the RRC2 cable
and the Ether cable to stress or
physical shock.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Turning the Power On and Off
Once the connections have been completed (p. 11), turn on power to your various
devices in the order specified. Turning on devices in the wrong order may cause
malfunction or damage to the speakers (or other components) of connected devices.
When Using the FC-300 as a MIDI Foot Controller
Turning On the Power
fig.power-on.eps
First, check that you are connected properly with the external MIDI
instrument. Then set the power switch on the FC-300 to “ON.”
fig.
In addition, it starts up with
the MIDI channel set to “1,”
but you can change the startup
MIDI channel if you want.
Refer to “Setting the MIDI
Transmit Channel” (p. 52).
When the power is turned on, the FC-300 starts up in Standard Mode.
Turning Off the Power
1
Switch off the power to the device connected to the FC-300.
2
Set the FC-300’s POWER switch to OFF.
When Using the FC-300 as a Dedicated Foot
Controller for an RRC2 IN Device (e.g., the VG-99)
Turning On the Power
First, check that you are connected properly with the RRC2 IN device. Then set the
power switch on the RRC2 IN device to “ON.”
fig.
Carefully connect the RRC2
cable or Ether cable all the way
in—until it is firmly to the
RRC2 connector.
2
Turn on the power of RRC2 IN device.
When the RRC2 IN device’s
POWER switch is set to ON,
the FC-300’s power switches
on automatically, regardless of
the position of the FC-300’s
POWER switch.
1
Connect the RRC2 cable.
Turning Off the Power
Switch off the power to the RRC2 IN device connected to the FC-300.
Although the FC-300 starts up
in Standard Mode, it may be
switched to a different mode
by means of settings received
from an RRC2 IN device.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
About the MODES
The FC-300 features the following four modes. The pedals function differently
depending on the mode that’s selected.
This manual describes each mode separately, while explaining the items available in
a particular mode.
See “Switching Modes” (p.
15) for an explanation of how
to choose a mode.
Standard Mode (p. 16)
This mode is for sending Program Change messages and Control Change messages.
You can use the pedals to send any Program Change messages.
Control Change Mode (p. 21)
This mode is for sending Control Change messages.
You can use this mode to send the Control Change messages assigned to the pedals,
and enhance the expressiveness of a performance.
You can also store up to five sets, or configurations, of settings for all of the pedals
(Pedal Setting function).
System Exclusive Mode (p. 28)
This mode is for sending System Exclusive messages.
You can use this mode to operate other equipment that accepts SysEx messages sent
from the FC-300.
Patch Mode (p. 29)
This mode is for transmitting multiple MIDI messages (MIDI streams) already saved
to patches.
Patches are areas of memory in which MIDI streams are stored; you can save up to
100 patches.
An individual patch can hold MIDI messages containing up to a maximum of
approximately 500 bytes.
Using Patch Mode, you can transmit groups of MIDI messages through one patch,
which allows you to switch the settings of multiple devices all at once.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Switching Modes
You can switch modes using one of the following methods.
• Press [MODE]
985
• Press a footswitch (BOSS FS-5U/FS-6; sold separately) connected to the MODE
jack
The explanations in this
manual include illustrations
that depict what should
typically be shown by the
display. Note, however, that
your unit may incorporate a
newer, enhanced version of the
system, so what you actually
see in the display may not
always match what appears in
the manual.
• Simultaneously press the [
] and [
] pedals
fig.
Standard Mode
Control Change Mode
System Exclusive Mode
Patch Mode
You can change the way the
mode is switched when using
About the Mode Indicators
[
] and [
] pedal or
footswitch. See “Switching
the Function of the MODE
Pedal Jack” (p. 51) for the
details on how to do this.
Standard Mode
Control Change Mode
System Exclusive Mode
Patch Mode
The current mode is indicated with the MODE indicators. You can switch modes
only from the top screen of any mode.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Standard Mode
This is the mode for sending Program Change messages and Control Change
messages.
Transmitting Program Change Messages
Pressing [
] and [
] pedals and the number pedals (1/6 – 5/10) transmits the
Program Change messages and Bank select messages for the corresponding number
pedals.
•
With the factory settings,
Program Change messages
are not transmitted just by
pressing the [
] pedals. To transmit
Program Change messages
just by pressing the [
and [ ] pedals, read
“Using the [ ] [
] and
1
2
Press the [
] pedal, and the numbers decrease by five; press the [
]
[
pedal, and the numbers increase by five.
]
The BANK/NUMBER display and Number pedal indicators flash.
]
Pedals to Make the
Press the number pedal (1/6–5/10) to select the number.
Settings” (p. 48).
The indicator for the number pedal pressed lights, and the Program Change message
is transmitted.
•
•
•
You can press the [
] or
[
] pedal to change
With the factory settings, transmission of Bank Select messages and Program
Change messages is in accordance with what is indicated in the BANK/NUMBER
display, as shown below.
patch numbers ten at a
time. For more detailed
the [
] [
] Pedal
BANK/NUMBER Display
Bank Select Message
Program Change Message
Step Size” (p. 49).
(MSB)
(LSB)
You can limit the range of
numbers switched. For
more detailed information,
see “Limiting the Range of
Banks That Can Be
Switched (Bank Extent)”
(p. 48).
001–128
129–130
0
1
0
0
1–128
29–30
Setting How Tones are Switched
You can set the way the FC-300 switches tones with the pedals and displays tone
numbers.
You can indicate the pedal
bank and number
Make the settings to match the specifications of the external MIDI devices you are
using (p. 47).
separately in the BANK/
NUMBER display. For
details, refer to “Setting
How Numbers are
Indicated” (p. 49).
•
•
You can stop output of
Bank Select messages. For
details, refer to “Setting
the Bank Select Output”
(p. 52).
You can change the Bank
Select messages. For details,
refer to “Setting the Bank
Select Value” (p. 53).
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Standard Mode
Transmitting Control Change Messages
You can transmit Control Change messages with expression pedals and control
pedals.
Using the Expression Pedals
For details about the all
In keeping with the movement of the expression pedal, Control Change messages
with the controller numbers set for each pedal are transmitted consecutively.
parameters and changes the
setting, refer to “Change the
Pedal Settings” (p. 19).
Each pedal is set at the factory as shown below.
Expression Pedal
EXP PEDAL 1
EXP PEDAL 2
CC#
7
1
Range
0–127
0–127
Using the Control Pedal and Expression Pedal Switch
When you use control pedals, you can use the control pedals to send the Control
Change messages for the controller numbers assigned to each of the pedals.
The Control pedal is a
momentary type pedal that
sends an ON message when
depressed and an OFF
In addition, you can activate the expression pedal switch by strongly pressing down
on the toe end of the pedal.
message when released. You
can change this to latch type
operation, which sends an ON
or OFF message each time you
Control Change messages with the controller numbers set for each pedal are
transmitted.
Each pedal is set at the factory as shown below.
Pedal
CC#
80
81
82
83
Range
0–127
0–127
0–127
0–127
Mode
CTL PEDAL 1
CTL PEDAL 2
EXP PEDAL SW 1
EXP PEDAL SW 2
LATCH
LATCH
LATCH
LATCH
You can use the control pedal
and expression pedal switch to
switch the AMP CONTROL
jacks – see “Change the Pedal
Settings” (p. 19).
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Standard Mode
Using the External Control Pedals and Expression Pedals
For details about the all
parameters and changes the
setting, refer to “Change the
Pedal Settings” (p. 19).
You can connect separately available footswitches and expression pedals and use the
external pedals just like the FC-300’s pedals to transmit Control Change messages,
When a BOSS FS-5U, FS-6 Footswitch is Connected,
Assigned to CTL Pedal:
These function in the same way as the FC-300’s built-in control pedals.
Connect a control pedal to the EXP PEDAL/CTL jack and set the FC-300 to enable
use of the pedal. (p. 50)
* If you have two FS-5U pedals or an FS-6 pedal connected to the CTL3,4 jack with a special
PCS-31 connecting cable (from Roland; available separately), the footswitch connected to
the plug with the white ring controls the setting of CONTROL 3, and the footswitch
connected to the plug with the red ring controls the setting of CONTROL 4.
See “Making the
Connections” (p. 11) for
instructions on setting the
polarity switch and mode
switch for the connected pedal.
* When only one footswitch is connected to the CTL3,4 jack, the CONTROL 3 settings are
enabled.
* When an FS-6 is connected to the CTL3,4 jack with an optional connection cable
(stereo 1/4” phone ←→ stereo 1/4” phone), pedal switch B operates according to the
CONTROL 3 settings, and pedal switch A operates according to the CONTROL 4
settings.
When a Roland EV-5, BOSS FV-500L or FV-500H is
Connected, Assigned to Expression Pedal:
These function in the same way as the FC-300’s built-in expression pedals.
Connect a expression pedal to the EXP PEDAL/CTL jack and set the FC-300 to
enable use of the pedal. (p. 50)
* These do not operate as expression pedal switches.
* If you are connecting a BOSS FV-500L/FV-500H, connect the pedal with an optional
connection cable (stereo 1/4” phone ←→ stereo 1/4” phone).
Controller Numbers for Each Pedal
Each pedal is set at the factory as shown below.
For details about the all
parameters and changes the
setting, refer to “Change the
Pedal Settings” (p. 19).
Pedal
CTL3
CTL4
CTL5
CTL6
CTL7
CTL8
EXP PEDAL 3
EXP PEDAL 4
EXP PEDAL 5
CC#
76
75
10
91
11
64
76
10
11
Range
0–127
0–127
0–127
0–127
0–127
0–127
0–127
0–127
0–127
Mode
LATCH
LATCH
LATCH
LATCH
LATCH
LATCH
-
-
-
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Standard Mode
Change the Pedal Settings
You can freely change the settings for each pedal.
1
In the Standard Mode’s top screen, press PARAMETER [
].
2
Press PARAMETER [
] [
] to display the pedal setting screens.
3
Press VALUE [
] [
] to change the value.
MIDI Messages
This selects the MIDI messages to be transmitted.
fig.05-009
MIDI Message
•
•
OFF
These do not output MIDI messages.
CC#1–CC#31, CC#33–CC#95
These output Control Change messages.
When the pedal is used as an expression pedal, consecutive values are output within
the range set with the Range setting. When the pedal is used as a control pedal or
other type of switch, the maximum value is output when the switch is on, and the
minimum value is output when the switch is off.
•
•
MIDI START / MIDI STOP / MIDI CONTINUE / MMC STOP / MMC PLAY /
MMC DEF PLAY / MMC FAST FWD / MMC REWIND / MMC REC STROBE /
MMC REC EXIT / MMC REC PAUSE / MMC PAUSE
This transmits MIDI Realtime messages and MMC messages.
When assigned to an expression pedal, messages are output once the pedal is
pressed downward past the halfway point; when assigned to a control pedal or other
switch, the messages are output when the switch is on.
P.BEND / CH.PRS
These transmit various Pitch Bend messages and Channel Pressure messages.
When assigned to an expression pedal, consecutive values are output within the
range set with the Range parameter. When assigned to a control pedal, the
maximum value is output when the switch is on, and the minimum value is output
when the switch is off.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Standard Mode
Range
The Range parameter is
enabled when CC#, P.BEND,
or CH.PRS is selected.
This sets the range for values that are transmitted.
fig.05-009
Minimum Maximum
Mode
This sets the switch mode.
The Mode parameter and AMP
Ctl Op parameter are enabled
when a control pedal or other
switch function is selected.
This parameter is ignored
when the pedal is used as a
expression pedal.
fig.05-009
Value
LATCH
MOMENTARY
Explanation
The ON and OFF will alternate each time you press the pedal.
The value will be ON while you press the pedal, and OFF when you
release the pedal.
AMP Ctl Op (Amp Control Operation)
This selects whether or not the AMP CONTROL jack is to be controlled.
fig.05-009
AMP CONTROL
1 jack
AMP CONTROL
2 jack
When the AMP Ctl Op parameter is set to ON and the AMP Polarity parameter is set
to Normal, control of AMP CONTROL with the pedal functions as shown below.
You can change the polarity of
the AMP CONTROL jacks. For
more detailed information, see
“Setting the Polarity of the
AMP CONTROL Jacks” (p.
50).
fig.05-009
When the pedal is OFF
Closed
Guitar Amp
(amps channel switching jack)
FC-300
(AMP CONTROL jack)
Open
When the pedal is ON
Guitar Amp
FC-300
(amps channel switching jack)
(AMP CONTROL jack)
4
When you have finished making the settings, press [EXIT] to return to the
initial screen.
The settings are saved, and the FC-300 returns to the initial screen.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Control Change Mode
About the Control Change Mode
This is the mode for sending Control Change messages.
In this mode, all the pedals can be used to send Control Change messages. You
should use this mode at times when you want to send a lot of Control Change
messages.
Pedal Setting Number
You can also store up to five sets, or configurations, of settings for all of the pedals
within the FC-300’s memory. Called pedal settings, these configurations can be
switched as needed (p. 26).
Transmitting Control Change Messages
Pressing the various pedals transmits the Control Change messages set for the
respective pedal over the selected MIDI channel.
Number Pedal (1/6–5/10)
Control Change messages with the controller numbers set for each pedal are
transmitted.
For details about the all
Each pedal is set at the factory as shown below.
parameters and changes the
setting, refer to “Change the
Pedal Settings” (p. 24).
Pedal
CC#
65
66
67
68
Range
0–127
0–127
0–127
0–127
0–127
Mode
Pedal
6
7
8
9
10
CC#
70
71
72
73
Range
0–127
0–127
0–127
0–127
0–127
Mode
1
2
3
4
5
LATCH
LATCH
LATCH
LATCH
LATCH
LATCH
LATCH
LATCH
LATCH
LATCH
69
74
[ ] [
] Pedal
These switch the number pedal functions.
Pedal
Explanation
[
[
]
]
This sets the number pedals to function as pedals 1–5.
This sets the number pedals to function as pedals 6–10.
When the [
for number pedals 1–5 become operable.
When the [ ] pedal is pressed, the [
for number pedals 6–10 become operable.
] pedal is pressed, the [
] pedal’s indicator lights, and the functions
] pedal’s indicator lights, and the functions
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Control Change Mode
Using the Expression Pedals
In keeping with the movement of the expression pedal, Control Change messages
with the controller numbers set for each pedal are transmitted consecutively.
For details about the all
parameters and changes the
setting, refer to “Change the
Pedal Settings” (p. 24).
Each pedal is set at the factory as shown below.
Expression Pedal
EXP PEDAL 1
EXP PEDAL 2
CC#
7
1
Range
0–127
0–127
Using the Control Pedal and Expression Pedal Switch
Control Change messages with the controller numbers set for each pedal are
transmitted.
The Control pedal is a
momentary type pedal that
sends an ON message when
depressed and an OFF
Each pedal is set at the factory as shown below.
Pedal
CC#
80
81
82
83
Range
0–127
0–127
0–127
0–127
Mode
message when released. You
can change this to latch type
operation, which sends an ON
or OFF message each time you
depress it – see “Mode” (p. 25).
CTL PEDAL 1
CTL PEDAL 2
EXP PEDAL SW 1
EXP PEDAL SW 2
LATCH
LATCH
LATCH
LATCH
You can use the control pedal
and expression pedal switch to
switch the AMP CONTROL
jacks – see “Change the Pedal
Settings” (p. 24).
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Control Change Mode
Using Additional Footswitches and Expression Pedals
For details about the all
parameters and changes the
setting, refer to “Change the
Pedal Settings” (p. 24).
You can connect separately available footswitches and expression pedals and use the
Realtime messages, and other such data.
When a BOSS FS-5U, FS-6 Footswitch is Connected,
Assigned to CTL Pedal:
These function in the same way as the FC-300’s built-in control pedals.
Connect a control pedal to the EXP PEDAL/CTL jack and set the FC-300 to enable
use of the pedal. (p. 50)
* If you have two FS-5U pedals or an FS-6 pedal connected to the CTL3,4 jack with a special
PCS-31 connecting cable (from Roland; available separately), the footswitch connected to
the plug with the white ring controls the setting of CONTROL 3, and the footswitch
connected to the plug with the red ring controls the setting of CONTROL 4.
See “Making the
Connections” (p. 11) for
instructions on setting the
polarity switch and mode
switch for the connected pedal.
* When only one footswitch is connected to the CTL3,4 jack, the CONTROL 3 settings are
enabled.
* When an FS-6 is connected to the CTL3,4 jack with an optional connection cable
(stereo 1/4” phone ←→ stereo 1/4” phone), pedal switch B operates according to the
CONTROL 3 settings, and pedal switch A operates according to the CONTROL 4
settings.
When a Roland EV-5, BOSS FV-500L or FV-500H is
Connected, Assigned to Expression Pedal:
These function in the same way as the FC-300’s built-in expression pedals.
Connect a expression pedal to the EXP PEDAL/CTL jack and set the FC-300 to
enable use of the pedal. (p. 50)
* These do not operate as expression pedal switches.
* If you are connecting a BOSS FV-500L or FV-500H, connect the pedal with an optional
connection cable (stereo 1/4” phone ←→ stereo 1/4” phone).
Controller Numbers of the Pedals
For details about the all
Each pedal is set at the factory as shown below.
parameters and changes the
setting, refer to “Change the
Pedal Settings” (p. 24).
Pedal
CTL3
CTL4
CTL5
CTL6
CTL7
CTL8
EXP PEDAL 3
EXP PEDAL 4
EXP PEDAL 5
CC#
76
75
10
91
11
64
76
10
11
Range
0–127
0–127
0–127
0–127
0–127
0–127
0–127
0–127
0–127
Mode
LATCH
LATCH
LATCH
LATCH
LATCH
LATCH
–
–
–
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Control Change Mode
Change the Pedal Settings
You can freely change the settings for each pedal.
1
In the Control Change Mode’s top screen, press PARAMETER [
].
settings are switched. To save
settings made for the pedals,
save them as pedal settings.
For more detailed information,
see “Storing Controller
Numbers Assigned to the
Pedals (Pedal Settings)” (p.
26).
2
Pressing PARAMETER [
] [
] to show the pedal setting screens.
3
Press VALUE [
] [
] to change the value.
MIDI Messages
This selects the MIDI messages to be transmitted.
fig.05-009
MIDI Message
•
•
OFF
These do not output MIDI messages.
CC#1–CC#31, CC#33–CC#95
These output Control Change messages.
When assigned to an expression pedal, consecutive values are output within the
range set with the Range parameter. When assigned to a control pedal, the
maximum value is output when the switch is on, and the minimum value is output
when the switch is off.
•
•
MIDI START / MIDI STOP / MIDI CONTINUE / MMC STOP / MMC PLAY /
MMC DEF PLAY / MMC FAST FWD / MMC REWIND / MMC REC STROBE /
MMC REC EXIT / MMC REC PAUSE / MMC PAUSE
This transmits MIDI Realtime messages and MMC messages.
When assigned to an expression pedal, messages are output once the pedal is
pressed downward past the halfway point; when assigned to a control pedal or other
switch, the messages are output when the switch is on.
P.BEND / CH.PRS
These transmit various Pitch Bend messages and Channel Pressure messages.
When assigned to an expression pedal, consecutive values are output within the
range set with the Range parameter. When assigned to a control pedal, the
maximum value is output when the switch is on, and the minimum value is output
when the switch is off.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Control Change Mode
Range
This sets the range for values that are transmitted.
fig.05-009
The Range parameter is
enabled when CC#, P.BEND,
or CH.PRS is selected for the
expression pedal.
Minimum Maximum
Mode
This sets the switch mode.
fig.05-009
The Mode parameter and AMP
Ctl Op parameter are enabled
when a control pedal or other
switch function is selected.
Value
Explanation
LATCH
The ON and OFF will alternate each time you press the pedal.
MOMENTARY
The value will be ON while you press the pedal, and OFF when you re-
lease the pedal.
AMP Ctl Op (Amp Control Operation)
This selects whether or not the AMP CONTROL jack is to be controlled.
fig.05-009
AMP CONTROL
1 jack
AMP CONTROL
2 jack
When the AMP Ctl Op parameter is set to ON and the AMP Polarity parameter is set
to Normal, control of AMP CONTROL with the pedal functions as shown below.
fig.05-00fig.05-009
When the pedal is OFF
Closed
Guitar Amp
(amps channel switching jack)
FC-300
(AMP CONTROL jack)
Open
When the pedal is ON
settings made for the pedals,
save them as pedal settings.
For more detailed information,
see “Storing Controller
Pedals (Pedal Settings)” (p.
26).
Guitar Amp
(amps channel switching jack)
FC-300
(AMP CONTROL jack)
4
5
When you have finished with the editing, press [EXIT].
The top screen appears.
After making the changes, follow the instructions in “Storing Controller
Numbers Assigned to the Pedals (Pedal Settings)” (p. 26) to save the settings.
You can change the polarity of
the AMP CONTROL jacks. For
more detailed information, see
“Setting the Polarity of the
AMP CONTROL Jacks” (p.
50).
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Control Change Mode
(Pedal Settings)
The FC-300 can store up to five different configurations of settings made for all of the
pedals (“Change the Pedal Settings” (p. 24)) in Control Change mode. These
configurations are called pedal settings, and you can switch them as needed.
1
After completing the pedal settings (p. 24), press [WRITE] in the top screen of
the Control Change Mode.
2
Select the number (1–5) for the pedal settings you want to store with VALUE
[
] [
].
The store-destination
of the pedal setting
3
4
Press [WRITE].
“Sure?” appears in the display.
If you want to write the setting, press [WRITE]; if you want to cancel the
procedure, press [EXIT].
Switching Control Numbers Assigned to the Pedals
Simultaneously
1
With the Control Change Mode screen displayed, press VALUE [
] [
].
The pedal settings are switched, and the current pedal setting number is indicated in
the BANK/NUMBER display.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Control Change Mode
Deleting a Pedal Setting
1
Press [WRITE] in the top screen of the Control Change Mode.
2
Pressing PARAMETER [
] [
] to show the “Delete” screen.
3
Select the number (1–5) for the pedal settings you want to delete with VALUE
] [ ].
[
The erased pedal setting
4
5
Press [WRITE].
“Sure?” appears in the display.
If you want to delete the setting, press [WRITE]; if you want to cancel the
procedure, press [EXIT].
27
Download from Www.Somanuals.com. All Manuals Search And Download.
System Exclusive Mode
This mode is for transmitting and receiving System Exclusive messages.
Pressing the FC-300’s pedals and pedals connected to the EXP PEDAL/CTL jacks
transmits the pedal status via System Exclusive messages.
In addition, display content and pedal indicators can be switched with System
Exclusive messages received by the FC-300.
* For more on the System Exclusive messages transmitted and received in System Exclusive
mode, refer to the “MIDI Implementation (p. 59).”
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Patch Mode
About the Patch Mode
This mode is used for storing combinations of multiple MIDI messages that you can
combine freely and transmitting these messages together in groups.
This mode allows you to control the settings for multiple devices, all just with the
FC-300.
When a patch name is set, the
patch name is indicated in the
top screen in Patch Mode.
Patch Number
Patch Name
About the Patch
A “patch” is a group of multiple MIDI messages (MIDI stream) and other settings
that are configured together as a single unit. The FC-300 can store up to 100
individual patches.(p. 44)
The patch can set the following parameters.
• Patch’s ON Stream
Group of MIDI messages transmitted when a patch is selected.
A “MIDI stream” is a number
of MIDI messages grouped
together.
• Patch’s OFF Stream
Group of MIDI messages transmitted when a different patch is selected or
when a pedal is released. These are used for canceling settings from ON
streams.
• Timing for transmission of the patch’s OFF stream
• CTL1,2 ON streams
These are the groups of MIDI messages transmitted when the pedals are
switched on.
• CTL1,2 OFF streams
These are the groups of MIDI messages transmitted when the pedals are
switched off.
• AMP CONTROL
You can set the status of the AMP CONTROL jacks when a patch is selected.
• Control pedal, expression pedal, and other settings
• Patch names
* An individual patch can hold MIDI messages containing up to a maximum of
approximately 500 bytes. Although the total amount of MIDI message data that can be
stored in Patch Mode is approximately 8 Kbytes, this amount of memory is shared by all
patches. Therefore, please note that not all patches can contain the full approximately 500
bytes.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Patch Mode
Transmitting Control Change Messages
You can transmit Control Change messages through operation of the expression
pedals, control pedals, and other controllers.
For details about the all
parameters and changes the
setting, refer to “Change the
Pedal Settings” (p. 42).
Using the Expression Pedals
In keeping with the movement of the expression pedal, Control Change messages
Each pedal is set at the factory as shown below.
Expression Pedal
EXP PEDAL 1 (Assign Number=1)
EXP PEDAL 2 (Assign Number=1)
CC#
7
1
Range
0–127
0–127
All Assign Numbers from 2 on are set to OFF. For more information about the Assign
Numbers, see “Change the Pedal Settings” (p. 42).
Using the Control Pedals and Expression Pedal
Switches
The Control pedal and EXP
that sends an ON or OFF
message each time you depress
it. You can change this to
momentary type operation,
which sends an ON message
when depressed and an OFF
message when released – see
“Mode” (p. 43).
You can connect separately available footswitches and expression pedals and use the
external pedals just like the FC-300’s pedals to transmit MIDI messages.
Each pedal is set at the factory as shown below.
Pedal
CTL PEDAL 1
CTL PEDAL 2
EXP PEDAL SW 1 (Assign Number=1)
EXP PEDAL SW 2 (Assign Number=1)
CC#
80
81
82
83
Range
0–127
0–127
0–127
0–127
Mode
LATCH
LATCH
LATCH
LATCH
All Assign Numbers from 2 on are set to OFF. For more information about the Assign
Numbers, see “Change the Pedal Settings” (p. 42).
You can use the control pedal
and expression pedal switch to
switch the AMP CONTROL
jacks – see “Change the Pedal
Settings” (p. 42).
30
Download from Www.Somanuals.com. All Manuals Search And Download.
Patch Mode
Using the External Control Pedals and Expression Pedals
For details about the all
parameters and changes the
setting, refer to “Change the
Pedal Settings” (p. 42).
You can connect separately available footswitches and expression pedals and use the
Realtime messages, and other such data.
When a BOSS FS-5U, FS-6 Footswitch is Connected,
Assigned to CTL Pedal:
These function in the same way as the FC-300’s built-in control pedals.
Connect a control pedal to the EXP PEDAL/CTL jack and set the FC-300 to enable
use of the pedal. (p. 50)
* If you have two FS-5U pedals or an FS-6 pedal connected to the CTL3,4 jack with a special
PCS-31 connecting cable (from Roland; available separately), the footswitch connected to
the plug with the white ring controls the setting of CONTROL 3, and the footswitch
connected to the plug with the red ring controls the setting of CONTROL 4.
See “Making the
Connections” (p. 11) for
instructions on setting the
polarity switch and mode
switch for the connected pedal.
* When only one footswitch is connected to the CTL3,4 jack, the CONTROL 3 settings are
enabled.
* When an FS-6 is connected to the CTL3,4 jack with an optional connection cable
(stereo 1/4” phone ←→ stereo 1/4” phone), pedal switch B operates according to the
CONTROL 3 settings, and pedal switch A operates according to the CONTROL 4
settings.
When a Roland EV-5, BOSS FV-500L or FV-500H is
Connected, Assigned to Expression Pedal:
These function in the same way as the FC-300’s built-in expression pedals.
Connect a expression pedal to the EXP PEDAL/CTL jack and set the FC-300 to
enable use of the pedal. (p. 50)
* These do not operate as expression pedal switches.
* If you are connecting a BOSS FV-500L or FV-500H, connect the pedal with an optional
connection cable (stereo 1/4” phone ←→ stereo 1/4” phone).
The Controller Number of Each Pedal
Each pedal is set at the factory as shown below.
You can set the range for
values that are transmitted,
refer to “Change the Pedal
Settings” (p. 42).
Pedal
CC#
76
75
10
91
11
64
76
10
11
Range
0–127
0–127
0–127
0–127
0–127
0–127
0–127
0–127
0–127
Mode
LATCH
LATCH
LATCH
LATCH
LATCH
LATCH
–
CTL3
CTL4
CTL5
CTL6
CTL7
CTL8
EXP PEDAL 3
EXP PEDAL 4
EXP PEDAL 5
–
–
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Patch Mode
Transmitting Patch Data
When a patch is selected with the [
] and [
] pedals and number pedals, the
MIDI messages saved to the patch are transmitted.
With the factory settings,
Program Change messages are
1
2
Press the [
] pedal, and the numbers decrease by five; press the [
]
pressing the [
pedals.
] and [
]
pedal, and the numbers increase by five.
To transmit Program Change
messages just by pressing the
The BANK/NUMBER display and Number pedal indicators flash.
[
] and [
] pedals, read
] [
“Using the [
]
The numbers are selected by pressing the number pedals (1/6–5/10).
Pedals to Make the Settings”
The patch for the selected number is selected (the pedal’s indicator lights), and the
MIDI messages in the ON stream within the patch are transmitted.
(p. 48).
Additionally, other settings included in the patch are enabled. A current patch’s OFF
streams are transmitted before the newly selected patch’s ON streams are
transmitted.
You can program the FC-300
so that pressing the [
] and
[
] pedals changes patch
numbers ten at a time. For
details, refer to “Setting the
[
] [
(p. 49).
You can release the number
pedal to transmit OFF stream
at a time. For more detailed
information, see “Setting the
Timing for Transmission of
OFF MIDI Streams” (p. 40).
Patch Number 100 is indicated
as P.00.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
Patch Mode
Creating Patches
In the Patch Mode’s top screen, when press PARAMETER [
setting screens appear in the display. Press PARAMETER [
parameter you want to change.
], the various pedal
] [ ] to select the
If you switch patches before
saving the MIDI messages you
have input to the patch, any
edited content is lost. To save
the changes you have made,
carry out the Write procedure,
refer to “Storing (Saving)
Patches” (p. 44).
The patch can set the following parameters.
• Patch’s ON Stream
• Patch’s OFF Stream
• The Transmit timing of the patch’s Off Stream
• ON Stream of the CTL pedal 1, 2
• OFF Stream of the CTL pedal 1, 2
• Amp Control
• Control Pedal, Expression Pedal, and Other Settings
• Patch Name
You can assign the following messages to ON streams and OFF streams.
Message
Channel
Message
Display
PC
CC
N.ON/N.OFF
C.PRS
K.PRS
Program Change Message
Control Change Message
Note On/Note Off Message
Channel Pressure Message
Polyphonic Key Pressure Message
Pitch Bend Message
P.BEND
REALTIME
Realtime Message
MIDI START
MIDI STOP
MIDI CONTINUE
System Exclusive Message
SYSEX
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Patch Mode
Editing MIDI Streams
1
In the Patch Mode’s top screen, press PARAMETER [
].
2
Use the PARAMETER [
] and [
] buttons to select the MIDI stream you
want to edit, then press [WRITE].
3
“Edit MIDI” appears in the screen; press [WRITE].
The screen for selecting the MIDI stream editing function appears.
The following display appears when the message is not assigned.
Message Number
4
5
Use the VALUE [
to be edited.
] and [
] to select the message number for the message
You can select only one point
to which no messages at all are
assigned.
If you are adding any message, press [INS]. The message is added before the number
of the currently selected message.
To delete a message, select the message number with VALUE [
[DEL].
] [
] then press
Use the following procedures to edit the MIDI stream for different types of
messages.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
Patch Mode
When Setting Channel Messages and Realtime Messages
1
2
Press PARAMETER [
] [
] to move the cursor to the MIDI message.
MIDI Message
MIDI Channel
When the MIDI channel is set
to Tx, the channel set with the
MIDI:Tx Channel parameter in
Utilities is set (p. 52).
Message Number
Data
Press VALUE [
] [
] to select the MIDI message to be edited.
MIDI Message
PC
CC
N.ON
N.OFF
C.PRS
Data
MIDI Channel (CH#), Program Number (PC#)
MIDI Channel (CH#), Controller Number (CC#), Value (VAL)
MIDI Channel (CH#), Note Number (NOTE#), Velocity (V)
MIDI Channel (CH#), Note Number (NOTE#), Velocity (V)
MIDI Channel (CH#), VALUE
K.PRS
P.BEND
REALTIME
MIDI Channel (CH#), Note Number (NOTE#), Velocity (V)
MIDI Channel (CH#), Value (MSB, LSB)
MIDI START/MIDI STOP/MIDI CONTINUE
3
4
Press PARAMETER [
to change.
] [
] to move the cursor to the parameter you want
Press VALUE [
] [
] to change the value.
If there is any other message you want to change, select the message number as
instructed in Step 4 of “Editing MIDI Streams” (p. 34), then repeat Steps 1-4.
5
After making the changes, follow the instructions in “Storing (Saving)
Patches” (p. 44) to save the MIDI messages to a patch.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Patch Mode
When Setting System Exclusive Messages
1
Press PARAMETER [
] [
] to move the cursor to the MIDI message.
MIDI Message
MIDI Channel
Message Number
Data
2
3
4
Press VALUE [
] [
] to select the “SYSEX.”
Press [WRITE] to display the advanced editing screen.
The maximum amount of data
that can be saved to a system
exclusive message is 256 bytes.
Press PARAMETER [
change.
] [
] to move the cursor to the data you want to
With Roland System Exclusive
messages, moving the cursor
to the message in front of F7
(the end of the transmitted
data) and pressing [WRITE]
performs a checksum and
inserts it there.
5
6
Press VALUE [
] [
] to change the value.
If you want to add a data, use PARAMETER [
the position where you want to make the addition, then press [INS]. If you
] [
] to move the cursor to
position where you want to delete, then press [DEL].
Repeat steps 4–6, edit the data.
7
8
When you have finished with the editing, press [EXIT].
After making the changes, follow the instructions in “Storing (Saving)
Patches” (p. 44) to save the MIDI messages to a patch.
36
Download from Www.Somanuals.com. All Manuals Search And Download.
Patch Mode
When Setting System Exclusive Messages Using the
Template
When assigning the following System Exclusive messages, use the template.
Template
GM SYS ON
GM SYS OFF
V-LINK ON
V-LINK OFF
MMC STOP
MMC PLAY
MMC REC EXIT
MMC REC PAUSE
MMC PAUSE
MMC RESET
MMC LOCATE
MMC DEF PLAY
MMC FAST FWD
MMC REWIND
MMC REC STROBE
1
Press PARAMETER [
] [
] to move the cursor to the MIDI message.
MIDI Message
MIDI Channel
Message Number
Data
2
3
Press VALUE [
] [
] to select the “SYSEX.”
Press PARAMETER [
] to move the cursor to the “Template.”
4
Press [WRITE] to display the template selection screen.
Template
5
6
Press VALUE [
Press [WRITE].
] [
] to select the template.
The contents of the template are input in the MIDI stream.
7
After making the changes, follow the instructions in “Storing (Saving)
Patches” (p. 44) to save the MIDI messages to a patch.
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Patch Mode
Copying and Moving MIDI Messages Within a Stream
You can copy MIDI messages saved within a MIDI stream.
Use this function when you want to program a number of similar messages in a
stream.
Messages in MIDI streams are output in the same order they are programmed.
To change the sequence of the messages in a stream, use the Move function.
1
2
Press PARAMETER [
] [
] to move the cursor to message number.
Press VALUE [
number.
] [
] to select you want to copy (or move) message
3
Press PARAMETER [
Press [WRITE].
] [
] to select the “MOVE” or “COPY.”
4
5
Press VALUE [
] [
] to select the copy destination (or move destination)
message number.
The copy (or move) message is inserted to the in front of the selected message
number.
6
7
Press [WRITE].
“Sure?” appears in the display; press [WRITE] once more.
8
After making the changes, follow the instructions in “Storing (Saving)
Patches” (p. 44) to save the MIDI messages to a patch.
38
Download from Www.Somanuals.com. All Manuals Search And Download.
Patch Mode
How to Copy MIDI Streams
You can copy an edited stream to a different patch or different stream.
1
In the Patch Mode’s top screen, press PARAMETER [
].
2
Press PARAMETER [
] [
] to select the stream to be used as the copy
source, then press [WRITE].
3
4
Press PARAMETER [
] [
] to select “Copy MIDI,” then press [WRITE].
Press VALUE [
] [
] to select the stream to be used as the copy source,
then press [WRITE].
5
Press VALUE [
] [
] to select the stream to be used as the copy
destination, then press [WRITE].
6
7
“Sure?” appears in the display; press [WRITE] once more.
After making the changes, follow the instructions in “Storing (Saving)
Patches” (p. 44) to save the MIDI messages to a patch.
39
Download from Www.Somanuals.com. All Manuals Search And Download.
Patch Mode
How to Delete MIDI Streams
You can delete content in streams.
1
In the Patch Mode’s top screen, press PARAMETER [
].
2
Press PARAMETER [
] [
] to select the stream from which you want to
delete data, then press [WRITE].
3
4
5
Press PARAMETER [
] [
] to select “Delete MIDI,” then press [WRITE].
“Sure?” appears in the display; press [WRITE] once more.
After making the changes, follow the instructions in “Storing (Saving)
Patches” (p. 44) to save the MIDI messages to a patch.
Setting the Timing for Transmission of OFF MIDI Streams
1
In the Patch Mode’s top screen, press PARAMETER [
].
2
Press PARAMETER [
] [
] to select “Off Timing.”
Setting the timing
for transmission
3
Press VALUE [
] [
] to set the value.
Explanation
Value
PEDAL RELEASE
After the patches are switched, the OFF stream is transmit-
The Off Timing parameter is
set to PATCH CHANGE when
shipped from the factory.
PATCH CHANGE
The stream is transmitted when the next patch is selected.
The OFF stream is transmitted immediately before the ON
stream for the next patch is transmitted.
4
After making the changes, follow the instructions in “Storing (Saving)
Patches” (p. 44) to save the MIDI messages to a patch.
40
Download from Www.Somanuals.com. All Manuals Search And Download.
Patch Mode
Setting the Amp Control
You can set the status of the AMP CONTROL jacks when patches are selected.
1
In the Patch Mode’s top screen, press PARAMETER [
].
2
Press PARAMETER [
] [
] to select “AMP Ctl.”
AMP CONTROL
1 jack
AMP CONTROL
2 jack
3
4
Press PARAMETER [
] [
] to select “1” or “2” of the AMP Ctl.
Press VALUE [
] [
] to change the value.
You can change the polarity of
the AMP CONTROL jacks. For
more detailed information, see
“Setting the Polarity of the
AMP CONTROL Jacks” (p.
50).
Control of AMP CONTROL when the AMP Pol. parameter (p. 50) is set to NORMAL
is as shown below.
Value
---
Explanation
The AMP CONTROL jack is disabled.
The AMP CONTROL jack is switched off (closed).
The AMP CONTROL jack is switched on (open).
OFF
ON
When the AMP Ctl is OFF
Closed
Guitar Amp
FC-300
(amps channel switching jack)
(AMP CONTROL jack)
Open
When the AMP Ctl is ON
Guitar Amp
FC-300
(amps channel switching jack)
(AMP CONTROL jack)
5
After making the changes, follow the instructions in “Storing (Saving)
Patches” (p. 44) to save the setting to a patch.
41
Download from Www.Somanuals.com. All Manuals Search And Download.
Patch Mode
Change the Pedal Settings
You can freely change the settings for each pedal.
1
In the Patch Mode’s top screen, press PARAMETER [
].
2
Press PARAMETER [
] [
] to select the each pedal settings screen.
The pedals being set appear at the left and upper of the screen.
You can set the following parameters:
• ON Stream
• OFF Stream
• Control Change Message (The pedal can be assigned to up to six messages.)
• Amp Control
3
Press VALUE [
] [
] to change the value.
Setting the ON Stream and OFF Stream
You can assign these in the same manner as streams set as patch parameters. (p. 34)
However, the timing for transmission of OFF streams follows the settings made in
Pedal mode. You can set ON streams and OFF streams only with the FC-300’s CTL
pedals.
Assign Number
The EXP PEDAL and EXP PEDAL SW can be assigned to up to six messages to be
transmitted. You can also assign one message to be transmitted to each of the pedals
connected to the rear panel’s EXP PEDAL/CTL jacks and FC-300’s CTL pedals.
Assign Number
MIDI Message
MIDI Channel
When the MIDI channel is set
to Tx, the channel set with the
MIDI:Tx Channel parameter in
Utilities is set (p. 52).
MIDI Channel
This sets the MIDI channel for the messages being transmitted.
MIDI Messages
This sets the range for values that are transmitted.
• Off
These do not output MIDI messages.
• CC#1 – CC#31, CC#33 – CC#95
These output Control Change messages.
When used to an expression pedal, consecutive values are output within the
range set with the Range parameter. When used to a control pedal, the
maximum value is output when the switch is on, and the minimum value is
output when the switch is off.
• MIDI START / MIDI STOP / MIDI CONTINUE / MMC STOP / MMC PLAY /
MMC DEF PLAY / MMC FAST FWD / MMC REWIND / MMC REC STROBE /
42
Download from Www.Somanuals.com. All Manuals Search And Download.
Patch Mode
MMC REC EXIT / MMC REC PAUSE / MMC PAUSE
This transmits MIDI Realtime messages and MMC messages.
When assigned to an expression pedal, messages are output once the pedal is
pressed downward past the halfway point; when assigned to a control pedal
or other switch, the messages are output when the switch is on.
• P.BEND/CH.PRS
These transmit various Pitch Bend messages and Channel Pressure messages.
When assigned to an expression pedal, consecutive values are output within
the range set with the Range parameter. When assigned to a control pedal, the
maximum value is output when the switch is on, and the minimum value is
output when the switch is off.
Range
This sets the range for values that are transmitted.
fig.05-009
The Range parameter is
Minimum Maximum
enabled only when CC#,
P.BEND, or CH.PRS is
selected.
Mode
This sets the switch mode.
fig.05-009
The Mode parameter and AMP
Ctl Op parameter are enabled
with control pedals and other
such switches. These
Value
LATCH
MOMENTARY
Explanation
parameters are disregarded
when the pedal is used as an
expression pedal.
The ON and OFF will alternate each time you press the pedal.
The value will be ON while you press the pedal, and OFF when you
release the pedal.
AMP Ctl Op (Amp Control Operation)
fig.05-009
AMP CONTROL
1 jack
AMP CONTROL
2 jack
Control of AMP CONTROL using a pedal when the AMP Ctl Op parameter is set to
ON and the AMP Pol. parameter (p. 50) is set to NORMAL is as shown below.
fig.05-009
When the pedal is OFF
Closed
You can change the polarity of
the AMP CONTROL jacks. For
more detailed information, see
“Setting the Polarity of the
AMP CONTROL Jacks” (p.
50).
Guitar Amp
(amps channel switching jack)
FC-300
(AMP CONTROL jack)
Open
When the pedal is ON
Guitar Amp
FC-300
(amps channel switching jack)
(AMP CONTROL jack)
43
Download from Www.Somanuals.com. All Manuals Search And Download.
Patch Mode
4
When you have finished with the editing, press [EXIT].
The settings made for the
The top screen appears.
pedals are lost when the patch
is switched. To save settings
made for the pedals, save them
as a patch. For more detailed
information, see “Storing
(Saving) Patches” (p. 44).
5
After making the changes, follow the instructions in “Storing (Saving)
Patches” (p. 44) to save the setting to a patch.
Set the Patch Name
1
Patch names can be up to 12
characters in length.
In the Patch mode’s top screen, press PARAMETER [
].
2
Press PARAMETER [
] [
] to select “Patch Name.”
When you press [INS], inserts
a blank space at the cursor
location. When you press
[DEL], deletes a character at
the cursor location.
3
Press PARAMETER [
enter the characters.
] to move the cursor, and press VALUE [
] [
] to
Patch names are indicated in
the top screen in Patch Mode.
Storing (Saving) Patches
To store patches you have created in memory, carry out the Write procedure.
1
In the Patch mode’s top screen, press [WRITE].
2
3
Press VALUE [
press [WRITE].
] [
] to select the save-destination patch number, then
“Sure?” appears in the display; press [WRITE] once more.
The set value is saved, and the FC-300 returns to the top screen.
44
Download from Www.Somanuals.com. All Manuals Search And Download.
Patch Mode
Deleting Patches
You can delete entire patches.
1
Select the patch you want to delete in the Patch mode’s top screen, then
press [WRITE].
2
Press PARAMETER [
Press [WRITE].
] to select “Delete.”
3
4
“Sure?” appears in the display; press [WRITE] once more.
The selected patch is deleted, and the FC-300 returns to the top screen.
45
Download from Www.Somanuals.com. All Manuals Search And Download.
Other Features
Setting the System Parameters
Set the system parameters with the following procedure.
1
Press [UTILITY].
The [UTILITY] indicator lights, and the Utility screen appears in the display.
2
Press PARAMETER [
] [
] to call up the parameter you want to set.
Parameters that can be set and their screens are described in the next section.
3
4
Press VALUE [
] [
] to set the various parameters.
When you’ve finished making the settings, press [UTILITY] or [EXIT].
The data is saved, and FC-300 returns to the top screen.
Adjusting the LCD Contrast
Depending on where the FC-300 is placed, the display (on the right) may become
difficult to read.
If this occurs, adjust the display contrast.
1
Press PARAMETER [
] [
] to select “SYS:LCD Contrast.”
2
3
Press VALUE [
] [
] to adjust the contrast.
When you’ve finished making the settings, press [UTILITY] or [EXIT].
Reducing Battery Consumption (Economy Mode)
When the FC-300 is run on battery power, setting Economy Mode to ON enables
approximately 1.8 times continuous running time of the normal FC-300’s operating
mode.
1
Press PARAMETER [
] [
] to select “SYS:Economy Mode.”
The display and indicators
may flicker when Economy
Mode is set to ON, but this
does not indicate a
2
3
Press VALUE [
] [
] to switch Economy Mode on and off.
malfunction.
When you’ve finished making the settings, press [UTILITY] or [EXIT].
46
Download from Www.Somanuals.com. All Manuals Search And Download.
Other Features
Setting the Method Used for Transmitting Program
Change messages in Standard Mode (PC Mode)
You can change the method used for transmitting program changes to match the
device connected to the FC-300.
1
Press PARAMETER [
] [
] to select “SYS:PC Mode.”
2
Press VALUE [
] [
] to make the setting.
When PC Mode is set to
EFFECTS, the Bank Select
messages actually output
include the Bank Select in the
table at the left together with
UTILITY MIDI:Bank Select
parameter (p. 47).
Value
EFFECTS
SOUND MODULE
Explanation
Optimal mode for switching effects processor patches
Optimal mode for switching sound module patches
When PC Mode parameter sets to “EFFECTS” and SYS:Bank Display parameter sets
to “LINEAR,” the FC-300’s BANK/NUMBER display and the transmitted bank
select messages and program change messages correspond as shown below.
BANK/NUMBER Display
Bank Select message
Program Change
message
You can switch how
information is indicated in the
BANK/NUMBER display (p.
49).
(MSB)
(LSB)
001–128
129–200
201–300
301–400
401–500
501–600
601–700
701–800
801–900
901–990
0
1
2
3
4
5
6
7
8
9
0
0
0
0
0
0
0
0
0
0
1–128
29-100
1–100
1–100
1–100
1–100
1–100
1–100
1–100
1–90
The MIDI Bank Select setting
increases and decreases the
MSB. You can also have this
change the LSB. For more
detailed information, see
“Setting the Bank Select
Output” (p. 52).
When set to “SOUND MODULE,” the FC-300’s LCD appears bank select MSB and
LSB, and the transmitted bank select message with program change message.
When PC Mode is set to
SOUND MODULE, the MSB
and LSB values upon power-
up will be the values set in
MIDI:Bank Select.
MSB
LSB
Program Change Number
Bank Select
3
When you’ve finished making the settings, press [UTILITY] or [EXIT].
47
Download from Www.Somanuals.com. All Manuals Search And Download.
Other Features
Using the [ ] [
] Pedals to Make the Settings
1
Press PARAMETER [
] [
] to select “SYS:Bnk Chg Mode.”
2
Press the VALUE [
] [
] to program the settings.
Here are some examples of operation in Standard Mode.
Value
Explanation
IMMEDIATE
Program changes are transmitted immediately when [
] or
[
] is pressed.
Example) When starting from “003,” pressing [
neously transmits PC#8.
] simulta-
WAIT FOR A NUM
RESET NUMBER
Program changes are transmitted when a number pedal is
pressed after [ ] or [ ] is pressed.
Example) Starting from “003,” after [
green number pedal indicators are flashing, pressing number
pedal 8 outputs PC#8.
] is pressed and all of the
Although program changes are transmitted immediately when
[
] or [
] is pressed, just as with Immediate, in this case, the
number furthest to the left is output.
Example) If starting from “003,” pressing [
transmits PC#6.
] simultaneously
3
When you’ve finished making the settings, press [UTILITY] or [EXIT].
Limiting the Range of Banks That Can Be Switched
(Bank Extent)
You can set an upper limit on the banks that can be switched, thus limiting the range
of banks that are switched and allowing you to select only the patches required.
This is enabled only when PC
Mode is set to EFFECTS.
1
Press PARAMETER [
] [
] to select “SYS:Bank Extent.”
2
3
Press VALUE [
] [
] to set the upper limit on the banks.
When you’ve finished making the settings, press [UTILITY] or [EXIT].
48
Download from Www.Somanuals.com. All Manuals Search And Download.
Other Features
Setting the [ ] [
] Pedal Step Size
You can set the size of the step made when the [
] [
] pedals are pressed.
1
Press PARAMETER [
] [
] to select “SYS:Bank Step.”
2
Press VALUE [
] [
] to make the setting.
Value
Explanation
5STEP
The number decreases or increases by five each time [
pressed.
The number decreases or increases by ten each time [
] or [
] or [
] is
] is
10STEP
pressed. Additionally, each time a number pedal is pressed, that pedal’s
number is switched.
Example) When “012” is indicated in BANK/NUMBER display, pressing
number pedal 2/7 switches it to “017.”
3
When you’ve finished making the settings, press [UTILITY] or [EXIT].
Setting How Numbers are Indicated
You can select the way numbers are indicated in Standard Mode to match that of the
connected device.
1
Press PARAMETER [
] [
] to select “SYS:Bank Display.”
2
Press VALUE [
] [
] to make the setting.
Value
Explanation
LINEAR
The bank and number are indicated as a single decimal number.
BANK&NUM
The bank and number are indicated as separate numbers. A dot
is displayed between the bank and number.
Example) The number indicated in LINEAR as “001” appears as
“01.1” with BANK&NUM.
FC-200
The numerals are indicated in the same way as with BANK &
NUM, but with the banks beginning with “00” in the display.
3
When you’ve finished making the settings, press [UTILITY] or [EXIT].
49
Download from Www.Somanuals.com. All Manuals Search And Download.
Other Features
Setting the Polarity of the AMP CONTROL Jacks
Change this parameter if the indicator on an amp connected to an AMP CONTROL
jack (1 or 2) does not correspond to the ON indicator (indicator lit) on the FC-300.
1
Press PARAMETER [
“SYS:AMP 2 Pol.”
] [
] to select “SYS:AMP 1 Pol.” or
2
Press VALUE [
] [
] to make the setting.
Value
Explanation
NORMAL
INVERT
The parameter is set to the factory setting.
Actual operation is the reverse of that indicated by the FC-300’s ON/OFF
indicator.
3
When you’ve finished making the settings, press [UTILITY] or [EXIT].
Determining the Role of an EXP PEDAL/CTL Jack
Follow the steps below to specify whether a pedal being connected to an EXP
PEDAL/CTL jack (on the rear panel) is a control pedal or an expression pedal. This
setting needs to be made individually for each jack.
1
Press PARAMETER [
or “SYS:E5/C7 Type.”
] [
] to select “SYS:E3/C3 Type”, “SYS:E4/C5 Type”
2
3
Press VALUE [
] [
] to make the setting.
Explanation
The jack will be used for connecting expression pedals.
Connect a Roland EV-5 or BOSS FV-500L or FV-500H.
Value
EXP PEDAL
CTL
The jack will be used for connecting control pedals.
Connect a BOSS FS-5U or FS-6.
When you’ve finished making the settings, press [UTILITY] or [EXIT].
50
Download from Www.Somanuals.com. All Manuals Search And Download.
Other Features
Switching the Function of the MODE Pedal Jack
This sets the modes that can be selected when the mode is switched with a pedal.
This setting allows you to toggle only between the modes you need when using the
pedal.
1
Press PARAMETER [
] [
] to select “SYS:MODE Pdl Seq.”
The actions performed by
simultaneously pressing the
[
] and [
] pedals also
conform to this setting.
Standard Mode
Patch Mode
Control Change
Mode
System Exclusive
Mode
You cannot set the lower case
letters in all modes.
2
3
Press PARAMETER [
] [
] to select the mode you want to set, then press
VALUE [
] [
] to make the setting.
Value
Uppercase letters
Lowercase letters
Explanation
These can be selected by pressing the pedal.
These cannot be selected by pressing the pedal.
When you’ve finished making the settings, press [UTILITY] or [EXIT].
Switching How the Pedal Indicators Light
You can have all unlit pedal indicators flash faintly instead.
This makes it easier to locate pedal positions on stage and in other darkened
environments.
1
Press PARAMETER [
] [
] to select “SYS:Pdl Indicate.”
2
3
Press VALUE [
] [
] to make the setting.
Value
OFF
ON
Explanation
All pedal indicators other than the lit pedal indicator remain off.
All pedal indicators other than the unlit pedal indicator flash.
When you’ve finished making the settings, press [UTILITY] or [EXIT].
51
Download from Www.Somanuals.com. All Manuals Search And Download.
Other Features
Setting the MIDI Transmit Channel
This sets the Transmit Channel of the MIDI messages.
1
Press PARAMETER [
] [
] to select “MIDI:Tx Channel.”
2
3
Press VALUE [
] [
] to set the transmit channel.
When you’ve finished making the settings, press [UTILITY] or [EXIT].
Setting the Device ID
This sets the Device ID used for transmitting and receiving system exclusive
messages.
1
Press PARAMETER [
] [
] to select “MIDI:Device ID.”
2
3
Press VALUE [
] [
] to set the Device ID.
When you’ve finished making the settings, press [UTILITY] or [EXIT].
Setting the Bank Select Output
This setting determines whether or not Bank Select messages as well as Program
Change messages are transmitted in Standard Mode.
1
Press PARAMETER [
] [
] to select “MIDI:Bnk Sel Out.”
2
3
Press VALUE [
] [
] to make the setting.
Value
OFF
ON (MSB INC)
Explanation
Bank Select messages are not transmitted.
The Bank Select (MSB) message is incremented (or decremented) by
one when the Program Change is incremented (or decremented).
The Bank Select (LSB) message is incremented (or decremented) by
one when the Program Change is incremented (or decremented).
ON (LSB INC)
When you’ve finished making the settings, press [UTILITY] or [EXIT].
52
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting the Bank Select Value
You can change the values of the Bank Select messages output in Standard Mode to
match the connected device. Values from the [
] [
] pedals are added to the
base values set here and then output. For details, refer to “Setting the Method Used
for Transmitting Program Change messages in Standard Mode (PC Mode)” (p.
47).
1
Press PARAMETER [
] [
] to select “MIDI:Bank Select.”
2
3
4
Press PARAMETER [
] [
] to select either “MSB” or “LSB.”
Press VALUE [
] [
] to make the setting.
When you’ve finished making the settings, press [UTILITY] or [EXIT].
Transmitting Data to an External MIDI Device (Bulk Dump)
On the FC-300, you can use System Exclusive messages to provide another FC-300
with identical settings, and save settings on a MIDI sequencer or other device.
Making the Connections
• When saving to a MIDI sequencer
For instructions on operating
the MIDI sequencer, see the
owner’s manual that came
with your MIDI sequencer.
with a MIDI cable.
• When transmitting data to another FC-300
Connect the sending FC-300’s MIDI OUT to the receiving FC-300’s MIDI IN
connector with a MIDI cable.
1. Set the Device ID for the transmitting and receiving FC-300s to the same
ID (p. 52).
2. Switch to the Bulk Load screen on the receiving FC-300 (p. 54).
Transmitting
1
Press PARAMETER [
] [
] to select “Bulk Dump.”
53
Download from Www.Somanuals.com. All Manuals Search And Download.
Other Features
2
Press VALUE [
] [
] to make the setting.
Value
Explanation
ALL
All settings (UTILITY, STANDARD, CONTROL, PATCH) are transmitted.
System parameter settings are transmitted.
Standard Mode settings are transmitted.
Control Change Mode settings are transmitted.
Patch Mode settings are transmitted.
UTILITY
STANDARD
CONTROL
PATCH
3
Press [WRITE].
The “Now Sending...” message appears in the display when the FC-300 sends the
data. The top screen appears in the display when the FC-300 finishes sending the
data.
If either ALL, CONTROL, or PATCH is selected in Step 2, the message “Erase Tmp
Data Sure?” is displayed.
Press [WRITE] again; the data currently being edited (unsaved) in Control Change
mode and Patch mode is erased, and then the bulk dump begins.
Receiving Data from an External MIDI Device (Bulk Load)
FC-300 can receive the setting saved in the sequencer or the other FC-300 with
identical settings.
Making the Connections
• When receiving data saved to a MIDI sequencer
Connect the MIDI sequencer’s MIDI OUT to the FC-300’s MIDI IN connector
with a MIDI cable.
For instructions on operating
the MIDI sequencer, see the
owner’s manual that came
with your MIDI sequencer.
Transmitting
1
Press PARAMETER [
] [
] to select “Bulk Load.”
Just as when transmitting data
to a MIDI sequencer, match the
FC-300’s and MIDI sequencer’s
Device ID settings (p. 52).
2
3
Transmit the data.
The “Now Receiving...” message appears in the display when the FC-300 receiving
the data.
The bulk load processing ended when the message “Now Waiting...” appears in the
display.
When you’ve finished receiving the data, press [UTILITY] or [EXIT].
The data is saved, and the FC-300 returns to the top screen.
54
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendices
Restoring the Factory Settings (Factory Reset)
You can restore all of the FC-300’s settings to their original factory settings.
This is referred to as “Factory Reset.”
Use the following procedure when carrying out Factory Reset.
1
Switch off the power.
2
Hold down VALUE [
] [
] and switch on the power.
The message “Factory Reset Are you sure?” appears in the display.
3
4
Press [WRITE].
Do not turn off the power to
the FC-300 while Factory Reset
is in progress.
Factory Reset is executed.
When the Factory Reset is finished, the message “Completed!” appears in the
display.
If you want to cancel the
factory reset operation, turn off
the power.
Switch off the power.
55
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendices
Adjusting the Expression Pedal
Although the FC-300’s EXP pedals are adjusted for optimal performance when
shipped from the factory, extended use over time and under certain usage
conditions may result in the pedals going out of adjustment. If you find the pedals
exhibiting problems, such as “a failure to completely shut off the volume when used
as volume pedals,” or “MIDI messages not being output in the range corresponding
to the set values,” you can readjust the pedals using the following procedure.
1
Hold down [UTILITY] and switch on the power.
2
When “EXP1:Set to MIN” is displayed, rock EXP PEDAL 1 all the way back (so
that the toe end of the pedal is raised). Release your foot from EXP PEDAL 1,
and then press [WRITE].
When you operate the
expression pedal, please be
careful not to get your fingers
pinched between the movable
part and the panel. In
households with small
children, an adult should
provide supervision until the
child is capable of following all
the rules essential for the safe
operation of the unit.
3
When “EXP1:Set to MAX” is displayed, rock EXP PEDAL 1 fully forward (so
that the heel end of the pedal is raised). Release your foot from EXP PEDAL 1,
and then press [WRITE].
4
When “EXP1:Threshold” appears in the display, set the sensitivity of the EXP
PEDAL SW 1 with VALUE [
] [
], and then press [WRITE].
EXP1:Threshold and
EXP2:Threshold can be set to
any value from 1 through 16.
The expression pedal switch
can be switched on and off
with less pressure as the value
is lowered.
5
6
When “EXP2:Set to MIN” is displayed, rock EXP PEDAL 2 all the way back (so
that the toe end of the pedal is raised). Release your foot from EXP PEDAL 2,
and then press [WRITE].
When “EXP2:Set to MAX” is displayed, rock EXP PEDAL 2 fully forward (so
that the heel end of the pedal is raised). Release your foot from EXP PEDAL 2,
and then press [WRITE].
7
8
When “EXP2:Threshold” appears in the display, set the sensitivity of the EXP
PEDAL SW 2 with VALUE [
] [
], and then press [WRITE].
When the message “Complete!” appears in the display, switch off the power.
56
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendices
Error Messages
Battery Low!
[Cause]
The batteries are depleted (6 x AA size).
[Solution]
Replace the batteries as soon as possible. (p. 11)
Memory Full!
[Cause 1]
The internal memory became full at the time the patch was saved.
[Solution 1] Delete any unnecessary patches. (p. 45)
[Cause 2]
The area of memory for the FC-300’s internal operations became full
while the patch was being edited (COPY, INS, etc).
[Solution 2] Delete MIDI messages within the patch. (p. 40)
MIDI Buffer Full!
[Cause]
Too many MIDI messages were received in a short time from an
external MIDI device than could be processed correctly.
[Solution]
Reduce the amount of MIDI message data transmitted by the external
MIDI device.
MIDI Offline!
[Cause]
There is a problem with the MIDI cable connection.
[Solution]
Check to make sure the cable has not been pulled out or is not
defective.
RRC2 Buffer Full!
[Cause]
Too many RRC2 control messages were received in a short time from
an external RRC2 IN device than could be processed correctly.
[Solution]
Reduce the amount of control message data transmitted by the
external RRC2 IN device.
RRC2 Offline!
[Cause]
There is a problem with the RRC2 cable connection.
[Solution]
Check to make sure the cable has not been pulled out or is not
defective.
57
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendices
Troubleshooting
If other operational problems occur, first check by using the following solutions:
If this does not resolve the problem, then contact your dealer or a nearby Roland
service station.
The power doesn’t come on
The batteries that are supplied
with the unit is for temporary
use, intended primarily for
testing this unit.
•
Is the specified AC adaptor (PSA series; sold separately) properly
connected?
Check connections again. Never use any AC adaptor other than one specified for
use with the FC-300 (p. 12).
•
Are the batteries dead?
Replace the new batteries (p. 11).
Power not turning off
When running on power
supplied by an RRC2 IN
device, the power is switched
on regardless of the position of
the POWER switch.
•
Is there an RRC2 IN device connected?
Switch the RRC2 IN device’s POWER switch to OFF (p. 13).
MIDI messages are not transmitted/received
•
•
•
•
Are the MIDI cables broken?
Try another set of MIDI cables.
Is the FC-300 correctly connected to the other MIDI device?
Check connections with the other MIDI device.
Do the MIDI channel settings of both devices match?
Make sure that the MIDI channels of both devices match (p. 52).
indicator is flashing.
Pressing a number pedal and selecting the number transmits the message.
•
When you send messages from the FC-300, make sure the FC-300 is set to
the settings appropriate for sending data.
Check the “Setting the Method Used for Transmitting Program Change
Change Messages” (p. 17) (p. 21) (p. 30).
Expression pedal switch not switching on and off / Fails to
Although the FC-300’s EXP
pedals are adjusted for optimal
performance when shipped
from the factory, extended use
over time and under certain
usage conditions may result in
the pedals going out of
•
Has the pedal gone out of adjustment?
Adjust the expression pedal (p. 56).
Display is faint or flickering
Check the following settings.
adjustment.
“Adjusting the LCD Contrast” (p. 46)
“Reducing Battery Consumption (Economy Mode)” (p. 46)
“Switching How the Pedal Indicators Light” (p. 51)
58
Download from Www.Somanuals.com. All Manuals Search And Download.
MIDI FOOT CONTROLLER
Model FC-300
Apr. 1, 2007
Version 1.00
MIDI Implementation
Command ID: CMD
The Command ID indicates the function of an Exclusive message.
Roland System Exclusive
Messages
The Command ID format may contain 00H in one or more places to
provide an extended data field.
The following are examples of valid Command IDs, each representing
a unique function:
01H
1. Data Format for Exclusive
Messages
02H
03H
Roland’s MIDI implementation uses the following data format for all
00H, 01H
00H, 02H
00H, 00H, 01H
Exclusive messages (type IV):
Byte
F0H
41H
DEV
MDL
CMD
[BODY]
F7H
Description
System Exclusive Status
Manufacturer ID (Roland)
Device ID
Main data: BODY
This field contains a message to be exchanged across an interface.
Model ID
Command ID
The exact data size and content will vary with the Model ID and
Command ID.
Main data
EOX (End of System Exclusive)
2. Address-mapped Data Transfer
Address mapping is a technique for transferring messages
MIDI status: F0H, F7H
An Exclusive message must be flanked by a pair of status codes,
starting with a Manufacturer ID immediately after F0H (MIDI version
1.0).
conforming to the data format given in Section 1.
It assigns a series of memory-resident records–waveform and tone
data, switch status, and parameters, for example, to specific locations
in a machine-dependent address space, thereby allowing access to
data residing at the address a message specifies.
Manufacturer ID: 41H
The Manufacturer ID identifies the manufacturer of a MIDI
instrument that sends an System Exclusive message. Value 41H
represents Roland’s Manufacturer ID.
Address-mapped data transfer is therefore independent of models
and data categories.
This technique allows use of two different transfer procedures: one-
way transfer and handshake transfer.
Device ID: DEV
The Device ID contains a unique value that identifies individual
One-way transfer procedure
(See Section 3 for details.)
devices in the implementation of several MIDI instruments.
It is usually set to 00H–0FH, a value smaller by one than that of a basic
channel, but value 00H–1FH may be used for a device with several
basic channels.
This procedure is suited to the transfer of a small amount of data.
It sends out an Exclusive message completely independent of the
receiving device’s status.
fig.Connection-Diagram1.eps
Model ID: MDL
Device (A)
Device (B)
The Model ID contains a value that identifies one model from another.
1
2
Different models, however, may share an identical Model ID if they
handle similar data.
MIDI OUT
MIDI IN
MIDI IN
MIDI OUT
The Model ID format may contain 00H in one or more places to
provide an extended data field.
Connection at point 2 is essential for “Request data” procedures. (See
Section 3.)
The following are examples of valid Model IDs, each representing a
unique model:
01H
02H
03H
00H, 01H
00H, 02H
00H, 00H, 01H
59
Download from Www.Somanuals.com. All Manuals Search And Download.
MIDI Implementation
Handshake-transfer procedure
(This device does not use this procedure)
3. One-way Transfer Procedure
This procedure sends out data until it has all been sent and is used
when the messages are so short that answerbacks need not be
checked.
This procedure initiates a predetermined transfer sequence
(handshaking) across the interface before data transfer takes place.
Handshaking ensures that reliability and transfer speed are high
For longer messages, however, the receiving device must acquire each
message in time with the transfer sequence, which inserts 20
milliseconds intervals. In this method, as for the receiving device, it is
necessary to receive data correctly in time.
enough to handle a large amount of data.
fig.Connection-Diagram2.eps
Device (A)
Device (B)
1
2
Types of Messages
MIDI OUT
MIDI IN
MIDI IN
Message
Request data 1
Data set 1
Command ID
RQ1 (11H)
DT1 (12H)
MIDI OUT
Connection at points 1 and 2 is essential.
Request data 1: RQ1 (11H)
This message is sent out when there is a need to acquire data from a
Notes on the above procedures
•
•
There are separate Command IDs for different transfer
procedures.
device at the other end of the interface.
It contains data for the address and size that specify designation and
length, respectively, of data required.
Devices A and B cannot exchange data unless they use the same
transfer procedure, share identical Device ID and Model ID,
and are ready for communication.
On receiving an RQ1 message, the remote device checks its memory
for the data address and size that satisfy the request.
If it finds them and is ready for communication, the device will
transmit a “Data set 1 (DT1)” message, which contains the requested
data.
Otherwise, the device won’t send out anything.
Byte
F0H
41H
DEV
MDL
11H
aaH
:
Description
System Exclusive Status
Manufacturer ID (Roland)
Device ID
Model ID
Command ID
Address MSB
:
:
:
Address LSB
ssH
Size MSB
:
:
:
:
Size LSB
sum
F7H
Check sum
EOX (End of System Exclusive)
•
•
The size of the requested data does not indicate the number of
bytes that will make up a DT1 message, but represents the
address fields where the requested data resides.
Some models are subject to limitations in data format used for a
single transaction. Requested data, for example, may have a
limit in length or must be divided into predetermined address
fields before it is exchanged across the interface.
•
•
The same number of bytes comprises address and size data,
which, however, vary with the Model ID.
The error-checking process uses a checksum that provides a bit
pattern where the last 7 bits are zero when values for an
60
Download from Www.Somanuals.com. All Manuals Search And Download.
MIDI Implementation
address, size, and that checksum are summed.
Example of Message Transactions
•
Device A sending data to Device B
Transfer of a DT1 message is all that takes place.
Data set 1: DT1 (12H)
fig.MessageTransaction1.eps
This message corresponds to the actual data transfer process.
Device (A)
Data Set 1
Device (B)
Because every byte in the data is assigned a unique address, a DT1
message can convey the starting address of one or more bits of data as
well as a series of data formatted in an address-dependent order.
* Wait for 20 msec or longer.
The MIDI standards inhibit non real-time messages from interrupting
an Exclusive one. This fact is inconvenient for devices that support a
“soft-thru” function.
Data Set 1
To maintain compatibility with such devices, Roland has limited the
DT1 to 256 bytes so that an excessively long message is sent out in
separate ‘segments.’
Data Set 1
•
Device B requesting data from Device A
Device B sends an RQ1 message to Device A.
Checking the message, Device A sends a DT1 message back to
Byte
F0H
41H
DEV
MDL
12H
aaH
:
Description
System Exclusive Status
Manufacturer ID (Roland)
Device ID
Model ID
Command ID
Address MSB
:
Device
fig.MessageTransaction2.eps
Device (A)
Device (B)
Data Set 1
Data Set 1
Request Data
:
:
* Wait for 20 msec or longer.
Address LSB
Data MSB
Data Set 1
ddH
:
:
:
:
Data Set 1
Data LSB
sum
F7H
Check sum
EOX (End of System Exclusive)
•
•
A DT1 message is capable of providing only the valid data
among those specified by an RQ1 message.
Some models are subject to limitations in data format used for a
single transaction. Requested data, or example, may have a
limit in length or must be divided into predetermined address
fields before it is exchanged across the interface.
•
•
The number of bytes comprising address data varies from one
Model ID to another.
The error-checking process uses a checksum that provides a bit
pattern where the last 7 bits are zero when values for an
address, data, and that checksum are summed.
61
Download from Www.Somanuals.com. All Manuals Search And Download.
MIDI Implementation
1. Recognized Receive Data
2. Transmitted Data
System Realtime Message
Transmitted Messages
Channel Voice Message
Active Sensing
Status
FEH
Note Off
Status
Second
kkH
Third
vvH
When FC-300 receives Active Sensing, it measures time intervals
between incoming messages. If the subsequent message will not come
within 400 msec after the previous one, FC-300 turns off Active
Sensing for a period and stops measuring message intervals.
8nH
n = MIDI Channel Number
kk = Note Number
vv = Velocity
0H-FH (ch.1-ch.16)
00H-7FH (0-127)
00H-7FH (0-127)
*
Specifically when Patch Mode is selected.
System Exclusive Message
Status
F0H
Data
iiH, ddH, ....., eeH
Status
F7H
Note On
Status
Second
Third
9nH
kkH
vvH
F0H
ii
System Exclusive Status
ID Number: The ID Number (manufacturer’s ID) is
used to distinguish one manufacturer’s System Exclu-
sive messages from another. Roland’s manufacturer ID
message (7FH) for extending the MIDI standard.
n = MIDI Channel Number
kk = Note Number
vv = Velocity
0H - FH (ch.1-ch.16)
00H-7FH (0-127)
01H-7FH (1-127)
*
Specifically when Patch Mode is selected.
dd, ..., ee 00H-7FH (0-127)
F7H
EOX (End of System Exclusive)
Polyphonic Key Pressure
System Exclusive messages that the FC-300 can receive are Data
Request (RQ1) and Data Set (DT1).
Status
Second
Third
AnH
kkH
vvH
For a detailed explanation about Data Request (RQ1) and Data Set
(DT1), refer to “Roland System Exclusive Messages” (p. 59) and
“3. Exclusive Communications” (p. 64).
n = MIDI Channel Number
kk = Note Number
vv = Polyphonic Key
Pressure
0H - FH (ch.1-ch.16)
00H-7FH (0-127)
00H-7FH (0-127)
*
Specifically when Patch Mode is selected.
Control Change
Status
Second
Third
BnH
ccH
vvH
n = MIDI Channel Number
cc = Control Number
vv = Control Value
0H-FH (ch.1-ch.16)
01H-1FH (1-31), 21H-5FH (33-95)
00H-7FH (0-127)
*
Does not transmit while in System Exclusive Mode.
Bank Select
Status
BnH
BnH
Second
00H
20H
Third
mmH
llH
n = MIDI Channel Number
0H-FH (ch.1-ch.16)
mm = Upper bytes of Bank Select Number
ll = Lower bytes of Bank Select Number
00H-7FH (0-127)
00H-7FH (0-127)
*
Specifically when Standard Mode and Patch Mode are selected.
62
Download from Www.Somanuals.com. All Manuals Search And Download.
MIDI Implementation
Program Change
System Exclusive Message
Status
Second
Status
CnH
ppH
F0H
iiH, ddH, ....., eeH
F7H
F0H
System Exclusive Status
41H (65)
00H-7FH (0-127)
n = MIDI Channel Number
pp = Program Number
0H-FH (ch.1-ch.16)
00H-7FH (prog.1-prog.128)
ii = ID Number
dd, ..., ee = data
F7H
*
Specifically when Standard Mode and Patch Mode are selected.
EOX (End of System Exclusive)
For a detailed explanation, see “Roland System Exclusive
Channel Pressure
Messages” (p. 59) and “3. Exclusive Communications” (p. 64).
Status
Second
DnH
vvH
MIDI Machine Control (MMC)
Status
F0H
Data
Status
F7H
n = MIDI Channel Number
vv = Channel Pressure
0H - FH (ch.1-ch.16)
00H-7FH (0-127)
7FH, 7FH, 06H, com
*
Does not transmit while in System Exclusive Mode.
Byte
F0H
7FH
7FH
06H
com
F7H
Description
System Exclusive Status
ID Number (Universal Realtime Message)
Device ID (Broadcast)
Sub-ID#1 (Machine Control Command)
Sub-ID#2 (MMC Command)
EOX (End of System Exclusive)
Pitch Bend Change
Status
EnH
Second
llH
Third
mmH
n = MIDI Channel Number
mm, ll = Pitch Bend
0H - FH (ch.1-ch.16)
00 00H - 40 00H - 7F 7FH
(-8192 - 0 - +8192)
*
FC-300 can set the following MMC commands.
com
01H
02H
03H
04H
05H
06H
07H
08H
09H
*
Does not transmit while in System Exclusive Mode.
STOP
PLAY
DEFERRED PLAY
FAST FORWARD
REWIND
RECORD STROBE
RECORD EXIT
RECORD PAUSE
PAUSE
System Realtime Message
Start
Status
FAH
*
Does not transmit while in System Exclusive Mode.
*
Does not transmit while in System Exclusive Mode.
Continue
Status
FBH
*
Does not transmit while in System Exclusive Mode.
Stop
Status
FCH
*
Does not transmit while in System Exclusive Mode.
Active Sensing
Status
FEH
*
*
During the normal operation, transmits at approx. 200 msec intervals.
When message intervals are being monitored at the input section, the
output of Active Sensing messages will cease for a certain period of time
if the input interval exceeds 400 msec.
63
Download from Www.Somanuals.com. All Manuals Search And Download.
MIDI Implementation
3. Exclusive Communications
4. Parameter Address Map
(Model ID = 00H 00H 20H)
Using Roland’s one-way System Exclusive message you can transfer
data between FC-300 and another device.
There are two type of the FC-300 System Exclusive message. FC-300
can send and receive the operation of this unit and display
You can use the following Model ID for the FC-300.
•
•
00H 00H 1EH (FC-300)
the FC-300’s internal parameters in the form of bulk data.
Address Block Map
00H 00H 20H (Foot Controller)
You can use System Exclusive messages to transmit and receive
the FC-300’s operational messages and display messages.
The Device ID can be set within the 00H to 1FH range.
Address (H)
10 00
20 00
30 00
40 00
50 00
60 00
68 00
70 00
71 00
Block
Description
Read/Write
Read
Write
Write
Read/Write
Write
Write
Write
Write
Mode Status
Pedal Status
For more on setting the Device ID, see “Setting the Device ID” (p.
Pedal LED Status
BANK/NUMBER Display Status
Controller Status
Message Display Status
Message Display User Font
Tuner Display Status
52).
Request Data 1 RQ1 (11H)
Byte
F0H
41H
dev
Description
System Exclusive Status
Manufacturer ID (Roland)
Device ID (dev: 00H-0FH)
Tuner Pitch Status
mdl
Model ID
(mdl: 00H 00H 1EH) FC-300
(mdl: 00H 00H 20H) Foot Controller
Mode Status (Individual area)
Address (H) Size (H) Data (H)
Parameter
Description
10 00
10 01
10 02
00 01
00 01
00 01
00-01
00-01
00-01
SYSEX Mode
Status *1
SYSEX Mode
Status *2
Function
Mode Status *3
0: Off, 1:On
11H
aaH
bbH
ssH
ttH
Command ID (RQ1)
Address MSB
Address LSB
Size MSB
Size LSB
0: Off, 1:On
0: Play, 1:TUNER
sum
F7H
Checksum
EOX (End of System Exclusive)
*1 Outputs on power-up or when Mode change is made.
Also outputs upon receiving Data Request (RQ1).
Data Set (DT1) is ignored.
DATA SET 1 DT1 (12H)
*2 Mode Status is changed when Data Set (DT1) is received.
Changes the System Exclusive Mode when On is received.
MODE pedal is pressed same operation when Off is received in
System Exclusive Mode.
Byte
F0H
41H
dev
Description
System Exclusive Status
Manufacturer ID (Roland)
Device ID (dev: 00H-0FH)
Model ID
(mdl: 00H 00H 1EH) FC-300
(mdl: 00H 00H 20H) Foot Controller
Command ID (DT1)
Address MSB
Address LSB
Data
*3 Changes the display of LCD in System Exclusive Mode when
Data Set (DT1) is received.
mdl
Appears the received data in Message Display Status Address
when PLAY is received.
12H
aaH
bbH
ddH
:
eeH
sum
F7H
Appears the TUNER screen and received data in Tuner Pitch
Status Address when TUNER is received. (FC-300 has not
TUNER function.)
:
Outputs when Data Request (RQ1) is received.
Data
Checksum
EOX (End of System Exclusive)
64
Download from Www.Somanuals.com. All Manuals Search And Download.
MIDI Implementation
Pedal Status (Individual area)
LED Status (Individual area)
Address (H) Size (H) Data (H)
Parameter
Description
Address (H) Size (H) Data (H)
Parameter
Pedal 1/6 Status
Pedal 2/7 Status
Pedal 3/8 Status
Pedal 4/9 Status
Pedal 5/10 Status
Description
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
30 00
30 01
30 02
30 03
30 04
30 05
30 06
30 07
30 08
30 09
00 01
00 01
00 01
00 01
00 01
00 01
00 01
00 01
00 01
00 01
00/7F
00/7F
00/7F
00/7F
00/7F
00/7F
00/7F
00/7F
00/7F
00/7F
Pedal 1/6 red LED
Status
Pedal 2/7 red LED
Status
Pedal 3/8 red LED
Status
Pedal 4/9 red LED
Status
Pedal 5/10 red LED
Status
Pedal 1/6 green LED OFF/ON
Status
Pedal 2/7 green LED OFF/ON
Status
Pedal 3/8 green LED OFF/ON
Status
OFF/ON
20 00
20 01
20 02
20 03
20 04
00 01
00 01
00 01
00 01
00 01
00/7F
00/7F
00/7F
00/7F
00/7F
OFF/ON
OFF/ON
OFF/ON
OFF/ON
21 00
21 01
21 02
21 03
21 04
00 01
00 01
00 01
00 01
00 01
00/7F
00/7F
00/7F
00/7F
00/7F
CTL Pedal 1 Status
CTL Pedal 2 Status
CTL Pedal 4 Status
CTL Pedal 6 Status
CTL Pedal 8 Status
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
22 00
22 01
00 01
00 01
00/7F
00/7F
EXP Pedal SW 1
Status
EXP Pedal SW 2
Status
OFF/ON
OFF/ON
Pedal 4/9 green LED OFF/ON
Status
Pedal 5/10 green
LED Status
OFF/ON
24 00
24 01
24 02
00 01
00 01
00 01
00-7F
00-7F
00-7F
EXP Pedal 1 Status
EXP Pedal 2 Status
CTL3/EXP3 Pedal
Status
CTL5/EXP4 Pedal
Status
CTL7/EXP5 Pedal
Status
0-127
0-127
0-127
31 00
31 01
00 01
00 01
00/7F
00/7F
CTL Pedal 1 LED
Status
CTL Pedal 2 LED
Status
OFF/ON
OFF/ON
24 03
24 04
00 01
00 01
00-7F
00-7F
0-127
0-127
32 00
32 01
00 01
00 01
00/7F
00/7F
EXP Pedal SW 1 LED OFF/ON
Status
EXP Pedal SW 2 LED OFF/ON
Status
25 00
25 01
00 01
00 01
00/7F
00/7F
UP Pedal Status
DOWN Pedal Status
OFF/ON
OFF/ON
•
•
•
Outputs when pedal is operated while in the System Exclusive
Mode.
35 00
35 01
00 01
00 01
00/7F
00/7F
UP Pedal LED Status OFF/ON
DOWN Pedal LED
Status
OFF/ON
Also outputs Data Set (DT1) when Data Request (RQ1) is
received.
•
•
Receives Data Set (DT1) in all mode, changes the LED status of
each pedal only in the System Exclusive Mode.
Data Set (DT1) is ignored.
Data Request (RQ1) is ignored.
BANK/NUMBER Display Status (Individual
area)
Address (H)
Size (H)
Data (H)
Parameter
Description
40 00
00 02
0abcdefg,
0000000h
Right
d
40 02
40 04
00 02
00 02
0abcdefg,
0000000h
0abcdefg,
0000000h
Center
Left
e
f
c
a
b
g
h
•
•
•
Receives Data Set (DT1) in all mode, changes the BANK/
NUMBER display status only in the System Exclusive Mode.
Each bit represents ON/OFF of corresponding display segment.
Bit “0” = OFF; “1” = ON
Data Request (RQ1) is ignored.
65
Download from Www.Somanuals.com. All Manuals Search And Download.
MIDI Implementation
Controller Status (Individual area)
Tuner Display Status (Individual area)
Address (H)
Size (H)
Data (H)
Parameter
Description
Address (H)
Size (H)
Data (H)
Parameter
Description
50 00
00 01
00/7F
AMP CON-
TROL 1 Status
AMP CON-
TROL 2 Status
OFF/ON
70 01
00 01
00/7F
ꢀ
ꢀ
C#/D Display
Status
C#/D
50 01
00 01
00/7F
OFF/ON
70 02
70 03
70 04
70 05
00 01
00 01
00 01
00 01
00/7F
00/7F
00/7F
00/7F
ꢀ
ꢀ
D#/E Display
D#/E
Status
•
•
Receives Data Set (DT1) in all mode.
ꢀ
ꢀ
F#/G Display
F#/G
Changes status of AMP CONTROL jack when Data Set (DT1) is
received.
Status
ꢀ
ꢀ
G#/A Display
Status
G#/A
•
Outputs when Data Request (RQ1) is received.
ꢀ
ꢀ
A#/B Display
A#/B
Status
Message Display Status (Individual area)
•
•
Receives Data Set (DT1) in all mode, changes the display of the
LCD when only Function Mode Status is TUNER.
Address (H) Size (H) Data (H)
Parameter
Description
60 00
00 10
00-07,
20-7D
Line 0
00-07: User Font
Data Request (RQ1) is ignored.
Column 0 data 20-7D: ASCII
characters
:
:
:
60 0F
00-07,
20-7D
Line 0
Column 15
data
Line 1
Column 0 data
Tuner Pitch Status (Individual area)
Address (H)
Size (H)
Data (H)
00, 01-06 String
Number
Parameter
Description
64 00
00 10
00-07,
20-7D
:
00-07,
20-7D
71 00
00 01
00: OFF
01: 1-6
:
:
71 01
00 01
00, 01-0D Tuner Note
Status
00: No Signal
01: C, 02: C#
03: D, 04: D#
05: E, 06: F
64 0F
Line 1
Column 15
data
07: F#, 08: G
09: G#, 0A: A
0B: A#, 0C: B
•
•
Receives Data Set (DT1) in all mode.
Outputs when Data Request (RQ1) is received.
71 02
00 01
00,
Tuner Cent
00: No Signal
01: -50
01–40–7F Status
40: 0
7F: 50
Message Display User Font (Individual
area)
•
•
•
Receives Data Set (DT1) when only Function Mode Status is
TUNER.
Address (H) Size (H) Data (H)
Parameter
Description
68 00
00 08
00-1F
User Font 1
Line 0 data
*1
Changes the display of the LCD when Data Set (DT1) is
received.
:
:
:
68 07
00-1F
User Font 1
Line 7 data
Data Request (RQ1) is ignored.
68 08
00 08
00 08
00-1F
User Font 2
Line 0 data
:
User Font 8
Line 7 data
:
:
:
68 38
00-1F
•
Receives Data Set (DT1) in all mode, changes the user font of the
LCD only in the System Exclusive Mode.
•
Data Request (RQ1) is ignored.
*1 The bitmap data of the user font following displayed in LCD.
Parameter
Data
User Font line0 data
User Font line1 data
User Font line2 data
User Font line3 data
User Font line4 data
User Font line5 data
User Font line6 data
User Font line7 data
000xxxxx
000xxxxx
000xxxxx
000xxxxx
000xxxxx
000xxxxx
000xxxxx
000xxxxx
66
Download from Www.Somanuals.com. All Manuals Search And Download.
MIDI Implementation
MIDI FOOT CONTROLLER
Model FC-300
Date : Apr. 1, 2007
Version : 1.00
MIDI Implementation Chart
Transmitted
Recognized
Remarks
Function...
Basic
Channel
Default
Changed
1–16
1–16
*1
*1
x
x
Memorized
Default
Messages
Altered
x
x
x
x
Mode
**************
Note
Number
0–127
*3
x
x
True Voice
**************
Velocity
x
x
Note ON
Note OFF
*3
*3
o 9n v=1–127
o 8n v=0–127
o 0–127
o 1–16
*3
*1
After
Touch
Key's
Ch's
x
x
Pitch Bend
o
x
*1
x
x
x
0, 32
1 – 31
33 – 95
o
o
o
Bank Select
*2
*1
*1
Control
Change
Program Number
1 – 128
*2
Program
Change
o
x
x
True #
*********
System Exclusive
o
o
Song Position
Song Select
Tune Request
x
x
x
x
x
x
Common
x
o
x
x
System
Realtime
Clock
Commands
*1
x
x
x
x
o
x
x
x
x
x
o
x
Local ON/OFF
All Notes OFF
All Sound OFF
Reset All Controller
Active Sense
AUX
Messages
System Reset
*1 Does not transmit while in System Exclusive Mode.
*2 Transmits while in Standard Mode and Patch Mode.
*3 Transmits while in Patch Mode.
Notes
Mode 1: OMNI ON, POLY
Mode 3: OMNI OFF, POLY
Mode 2: OMNI ON, MONO
Mode 4: OMNI OFF, MONO
o: Yes
x: No
67
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
FC-300 : MIDI FOOT CONTROLLER
Connectors
MIDI connectors (IN, OUT)
MODE jack
EXP PEDAL/CTL jack (3/3,4 4/5,6 5/7,8)
AMP CONTROL jack (1, 2)
RRC2 OUT connector
DC IN jack
Controls
Number pedals 1/6–5/10
[
] [
] pedals
CTL pedals (1, 2)
EXP PEDAL (1, 2)
PARAMETER [
] [
] button
VALUE [
] [
] button
UTILITY button
MODE button
EXIT button
WRITE button
POWER switch
Display
BANK/NUMBER display (7 segments w/ dots, 3 characters LED)
LCD (16 characters x 2 lines with backlit)
MODE indicators (STANDARD, CONTROL, SYS EX, PATCH)
UTILITY button indicator
Indicators
WRITE button indicator
Number pedal indicators 1/6–5/10 (When the number pedal 1-5 is selected, the indicator lights in red.
When the number pedal 6-10 is selected, the indicator lights in green.)
[
] [
] pedal indicators
CTL pedal indicators (1, 2)
EXP PEDAL indicators (1, 2)
100
Number of Patches
(Patch Mode)
Power Supply
9 V DC: Dry battery (AA) type x 6
AC Adaptor (BOSS PSA series; sold separately)
RRC2 (Supplied from RRC2 IN device)
Current Draw
94 mA (When Economy Mode is OFF.)
61 mA (When Economy Mode is ON.)
Expected battery
life under continu-
ous use (Carbon):
6.5 hours or longer (When Economy Mode is OFF)
12 hours or longer (When Economy Mode is ON)
* These figures will vary depending on the actual conditions of use.
Dimensions
550 (W) x 250 (D) x 76 (H) mm
21-11/16 (W) x 9-7/8 (D) x 3 (H) inches
5.3 kg / 11 lbs 11 oz (including batteries)
Owner’s Manual
Weight
Accessories
Dry battery R6 (AA) type (carbon) x 6
Roland Service
Options
AC Adaptor: BOSS PSA series
Footswitch: BOSS FS-5U, FS-6
Expression Pedal: Roland EV-5, BOSS FV-500L, FV-500H
* In the interest of product development, the specifications and/or appearance of this unit are subject to change without prior notice.
68
Download from Www.Somanuals.com. All Manuals Search And Download.
Numerics
A
AMP 1 Pol. ...................................................................... 50
L
Mode ................................................................... 20, 25, 43
B
BANK/NUMBER display .............................................. 7
Bulk Load ....................................................................... 54
N
C
PC Mode ......................................................................... 47
D
E
Error Messages .............................................................. 57
EXIT button ...................................................................... 8
EXP PEDAL 1, 2 ............................................................... 9
EXP PEDAL SW 1, 2 ....................................................... 9
EXP PEDAL SW indicators ............................................ 9
EXP PEDAL/CTL jack .................................................. 10
RRC2 OUT connector .................................................... 10
S
Set to MAX ..................................................................... 56
Set to MIN ....................................................................... 56
Standard Mode ........................................................ 14, 16
Storing (Saving) Patches ............................................... 44
69
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
System Exclusive Mode ................................................ 14
System Parameters ........................................................ 46
T
Threshold ........................................................................ 56
Tx Channel ..................................................................... 52
U
UTILITY button ............................................................... 8
V
VALUE button ................................................................. 8
W
WRITE button .................................................................. 8
70
Download from Www.Somanuals.com. All Manuals Search And Download.
For the U.K.
IMPORTANT: THE WIRES IN THIS MAINS LEAD ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE.
BLUE:
NEUTRAL
BROWN: LIVE
As the colours of the wires in the mains lead of this apparatus may not correspond with the coloured markings identifying
the terminals in your plug, proceed as follows:
The wire which is coloured BLUE must be connected to the terminal which is marked with the letter N or coloured BLACK.
The wire which is coloured BROWN must be connected to the terminal which is marked with the letter L or coloured RED.
Under no circumstances must either of the above wires be connected to the earth terminal of a three pin plug.
For EU Countries
This product complies with the requirements of European Directive 89/336/EEC.
For the USA
FEDERAL COMMUNICATIONS COMMISSION
RADIO FREQUENCY INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
–
–
–
–
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Unauthorized changes or modification to this system can void the users authority to operate this equipment.
This equipment requires shielded interface cables in order to meet FCC class B Limit.
For Canada
NOTICE
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
AVIS
Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
Download from Www.Somanuals.com. All Manuals Search And Download.
Information
When you need repair service, call your nearest Roland Service Center or authorized Roland
distributor in your country as shown below.
PHILIPPINES
CURACAO
URUGUAY
NORWAY
JORDAN
AFRICA
G.A. Yupangco & Co. Inc.
339 Gil J. Puyat Avenue
Makati, Metro Manila 1200,
PHILIPPINES
Zeelandia Music Center Inc.
Orionweg 30
Todo Musica S.A.
Francisco Acuna de Figueroa
1771
Roland Scandinavia Avd.
MUSIC HOUSE CO. LTD.
Kontor Norge
FREDDY FOR MUSIC
P. O. Box 922846
Amman 11192 JORDAN
TEL: (06) 5692696
EGYPT
Al Fanny Trading Office
9, EBN Hagar A1 Askalany
Street,
ARD E1 Golf, Heliopolis,
Cairo 11341, EGYPT
TEL: 20-2-417-1828
Curacao, Netherland Antilles
TEL:(305)5926866
Lilleakerveien 2 Postboks 95
Lilleaker N-0216 Oslo
NORWAY
C.P.: 11.800
Montevideo, URUGUAY
TEL: (02) 924-2335
TEL: (02) 899 9801
DOMINICAN REPUBLIC
Instrumentos Fernando Giraldez
Calle Proyecto Central No.3
Ens.La Esperilla
Santo Domingo,
Dominican Republic
TEL:(809) 683 0305
TEL: 2273 0074
SINGAPORE
SWEE LEE MUSIC
COMPANY PTE. LTD.
150 Sims Drive,
SINGAPORE 387381
TEL: 6846-3676
KUWAIT
EASA HUSAIN AL-YOUSIFI
& SONS CO.
Abdullah Salem Street,
Safat, KUWAIT
VENEZUELA
Instrumentos Musicales
Allegro,C.A.
Av.las industrias edf.Guitar
POLAND
ROLAND POLSKA SP. Z O.O.
UL. Gibraltarska 4.
PL-03 664 Warszawa
POLAND
REUNION
Maison FO - YAM Marcel
25 Rue Jules Hermann,
Chaudron - BP79 97 491
Ste Clotilde Cedex,
import
TEL: 243-6399
#7 zona Industrial de Turumo
Caracas, Venezuela
TEL: (212) 244-1122
TEL: (022) 679 4419
ECUADOR
Mas Musika
Rumichaca 822 y Zaruma
Guayaquil - Ecuador
TAIWAN
ROLAND TAIWAN
ENTERPRISE CO., LTD.
Room 5, 9fl. No. 112 Chung
Shan N.Road Sec.2, Taipei,
TAIWAN, R.O.C.
LEBANON
Chahine S.A.L.
Gerge Zeidan St., Chahine
Bldg., Achrafieh, P.O.Box: 16-
5857
Beirut, LEBANON
TEL: (01) 20-1441
PORTUGAL
Roland Iberia, S.L.
Portugal Office
Cais das Pedras, 8/9-1 Dto
4050-465, Porto, PORTUGAL
TEL: 22 608 00 60
REUNION ISLAND
TEL: (0262) 218-429
TEL:(593-4)2302364
SOUTH AFRICA
T.O.M.S. Sound & Music
(Pty)Ltd.
2 ASTRON ROAD DENVER
JOHANNESBURG ZA 2195,
SOUTH AFRICA
TEL: (011)417 3400
FAX: (011)417 3462
EUROPE
EL SALVADOR
OMNI MUSIC
75 Avenida Norte y Final
Alameda Juan Pablo II,
Edificio No.4010 San Salvador,
EL SALVADOR
TEL: (02) 2561 3339
AUSTRIA
Roland Elektronische
Musikinstrumente HmbH.
ROMANIA
FBS LINES
Piata Libertatii 1,
535500 Gheorgheni,
ROMANIA
OMAN
THAILAND
TALENTZ CENTRE L.L.C.
Malatan House No.1
Al Noor Street, Ruwi
SULTANATE OF OMAN
TEL: 2478 3443
Theera Music Co. , Ltd.
330 Soi Verng NakornKasem,
New Road, Sumpantawongse,
Bangkok 10100, THAILAND
TEL: (02) 224-8821
Austrian Office
Eduard-Bodem-Gasse 8,
A-6020 Innsbruck, AUSTRIA
TEL: (0512) 26 44 260
TEL: 262-0788
TEL: (266) 364 609
Paul Bothner(PTY)Ltd.
Royal Cape Park, Unit 24
Londonderry Road, Ottery 7800
Cape Town, SOUTH AFRICA
TEL: (021) 799 4900
GUATEMALA
BELGIUM/FRANCE/
HOLLAND/
LUXEMBOURG
Roland Central Europe N.V.
Houtstraat 3, B-2260, Oevel
(Westerlo) BELGIUM
RUSSIA
MuTek
Dorozhnaya ul.3,korp.6
117 545 Moscow, RUSSIA
TEL: (095) 981-4967
QATAR
Al Emadi Co. (Badie Studio &
Stores)
P.O. Box 62, Doha, QATAR
TEL: 4423-554
Casa Instrumental
Calzada Roosevelt 34-01,zona 11
Ciudad de Guatemala
Guatemala
AUSTRALIA/
NEW ZEALAND
TEL:(502) 599-2888
SLOVAKIA
HONDURAS
Almacen Pajaro Azul S.A. de C.V.
BO.Paz Barahona
3 Ave.11 Calle S.O
San Pedro Sula, Honduras
TEL: (504) 553-2029
AUSTRALIA/
NEW ZEALAND
Roland Corporation
Australia Pty.,Ltd.
38 Campbell Avenue
Dee Why West. NSW 2099
AUSTRALIA
SAUDI ARABIA
aDawliah Universal
Electronics APL
Corniche Road, Aldossary
Bldg., 1st Floor, Alkhobar,
SAUDI ARABIA
ASIA
TEL: (014) 575811
DAN Acoustic s.r.o.
Povazská 18.
CHINA
Roland Shanghai Electronics
Co.,Ltd.
5F. No.1500 Pingliang Road
Shanghai 200090, CHINA
TEL: (021) 5580-0800
CROATIA
ART-CENTAR
Degenova 3.
HR - 10000 Zagreb
TEL: (1) 466 8493
SK - 940 01 Nové Zámky
TEL: (035) 6424 330
SPAIN
Roland Iberia, S.L.
Paseo García Faria, 33-35
08005 Barcelona SPAIN
TEL: 93 493 91 00
MARTINIQUE
Musique & Son
Z.I.Les Mangle
97232 Le Lamantin
Martinique F.W.I.
TEL: 596 596 426860
P.O.Box 2154, Alkhobar 31952
SAUDI ARABIA
TEL: (03) 898 2081
CZECH REP.
For Australia
CZECH REPUBLIC
DISTRIBUTOR s.r.o
Voctárova 247/16
CZ - 180 00 PRAHA 8,
CZECH REP.
Roland Shanghai Electronics
Co.,Ltd.
(BEIJING OFFICE)
10F. No.18 3 Section Anhuaxili
Chaoyang District Beijing
100011 CHINA
Tel: (02) 9982 8266
For New Zealand
Tel: (09) 3098 715
SYRIA
Technical Light & Sound
Center
Rawda, Abdul Qader Jazairi St.
Bldg. No. 21, P.O.BOX 13520,
Damascus, SYRIA
SWEDEN
Roland Scandinavia A/S
SWEDISH SALES OFFICE
Danvik Center 28, 2 tr.
S-131 30 Nacka SWEDEN
TEL: (0)8 702 00 20
Gigamusic SARL
10 Rte De La Folie
97200 Fort De France
Martinique F.W.I.
TEL: 596 596 715222
TEL: (2) 830 20270
CENTRAL/LATIN
AMERICA
TEL: (010) 6426-5050
DENMARK
TEL: (011) 223-5384
Roland Scandinavia A/S
Nordhavnsvej 7, Postbox 880,
DK-2100 Copenhagen
DENMARK
HONG KONG
Tom Lee Music Co., Ltd.
Service Division
22-32 Pun Shan Street, Tsuen
Wan, New Territories,
HONG KONG
SWITZERLAND
Roland (Switzerland) AG
Landstrasse 5, Postfach,
CH-4452 Itingen,
SWITZERLAND
TEL: (061) 927-8383
ARGENTINA
Instrumentos Musicales S.A.
Av.Santa Fe 2055
(1123) Buenos Aires
ARGENTINA
TEL: (011) 4508-2700
TURKEY
ZUHAL DIS TICARET A.S.
Galip Dede Cad. No.37
Beyoglu - Istanbul / TURKEY
TEL: (0212) 249 85 10
MEXICO
Casa Veerkamp, s.a. de c.v.
Av. Toluca No. 323, Col. Olivar
de los Padres 01780 Mexico
D.F. MEXICO
TEL: 3916 6200
FINLAND
Roland Scandinavia As, Filial
Finland
Elannontie 5
FIN-01510 Vantaa, FINLAND
TEL: (0)9 68 24 020
TEL: 2415 0911
TEL: (55) 5668-6699
U.A.E.
Zak Electronics & Musical
Instruments Co. L.L.C.
Zabeel Road, Al Sherooq Bldg.,
No. 14, Grand Floor, Dubai,
U.A.E.
UKRAINE
EURHYTHMICS Ltd.
P.O.Box: 37-a.
Nedecey Str. 30
UA - 89600 Mukachevo,
UKRAINE
Parsons Music Ltd.
BARBADOS
NICARAGUA
Bansbach Instrumentos
Musicales Nicaragua
Altamira D'Este Calle Principal
de la Farmacia 5ta.Avenida
1 Cuadra al Lago.#503
Managua, Nicaragua
8th Floor, Railway Plaza, 39
Chatham Road South, T.S.T,
Kowloon, HONG KONG
TEL: 2333 1863
A&B Music Supplies LTD
12 Webster Industrial Park
Wildey, St.Michael, Barbados
TEL: (246)430-1100
GERMANY
Roland Elektronische
Musikinstrumente HmbH.
Oststrasse 96, 22844
Norderstedt, GERMANY
TEL: (040) 52 60090
TEL: (04) 3360715
TEL: (03131) 414-40
INDIA
Rivera Digitec (India) Pvt. Ltd.
409, Nirman Kendra
Mahalaxmi Flats Compound
Off. Dr. Edwin Moses Road,
Mumbai-400011, INDIA
TEL: (022) 2493 9051
BRAZIL
Roland Brasil Ltda.
Rua San Jose, 780 Sala B
Parque Industrial San Jose
Cotia - Sao Paulo - SP, BRAZIL
TEL: (011) 4615 5666
UNITED KINGDOM
TEL: (505)277-2557
Roland (U.K.) Ltd.
Atlantic Close, Swansea
Enterprise Park, SWANSEA
SA7 9FJ,
NORTH AMERICA
PANAMA
SUPRO MUNDIAL, S.A.
Boulevard Andrews, Albrook,
Panama City, REP. DE
PANAMA
GREECE/CYPRUS
STOLLAS S.A.
Music Sound Light
155, New National Road
Patras 26442, GREECE
TEL: 2610 435400
CANADA
Roland Canada Ltd.
(Head Office)
5480 Parkwood Way
Richmond B. C., V6V 2M4
CANADA
UNITED KINGDOM
TEL: (01792) 702701
CHILE
Comercial Fancy II S.A.
Rut.: 96.919.420-1
Nataniel Cox #739, 4th Floor
Santiago - Centro, CHILE
TEL: (02) 688-9540
INDONESIA
PT Citra IntiRama
J1. Cideng Timur No. 15J-150
Jakarta Pusat
INDONESIA
TEL: (021) 6324170
TEL: 315-0101
PARAGUAY
Distribuidora De
Instrumentos Musicales
J.E. Olear y ESQ. Manduvira
Asuncion PARAGUAY
TEL: (595) 21 492147
MIDDLE EAST
TEL: (604) 270 6626
HUNGARY
Roland East Europe Ltd.
Warehouse Area ‘DEPO’ Pf.83
H-2046 Torokbalint,
HUNGARY
BAHRAIN
Moon Stores
No.16, Bab Al Bahrain Avenue,
P.O.Box 247, Manama 304,
State of BAHRAIN
COLOMBIA
Centro Musical Ltda.
Cra 43 B No 25 A 41 Bododega 9
Medellin, Colombia
Roland Canada Ltd.
(Toronto Office)
170 Admiral Boulevard
Mississauga On L5T 2N6
CANADA
KOREA
Cosmos Corporation
1461-9, Seocho-Dong,
Seocho Ku, Seoul, KOREA
TEL: (02) 3486-8855
TEL: (23) 511011
PERU
Audionet
Distribuciones Musicales SAC
Juan Fanning 530
Miraflores
TEL: (574)3812529
TEL: 17 211 005
TEL: (905) 362 9707
IRELAND
Roland Ireland
G2 Calmount Park, Calmount
Avenue, Dublin 12
Republic of IRELAND
TEL: (01) 4294444
COSTA RICA
JUAN Bansbach Instrumentos
Musicales
Ave.1. Calle 11, Apartado
10237,
San Jose, COSTA RICA
TEL: 258-0211
MALAYSIA
IRAN
MOCO INC.
No.41 Nike St., Dr.Shariyati Ave.,
Roberoye Cerahe Mirdamad
Tehran, IRAN
U. S. A.
Roland Asia Pacific Sdn. Bhd.
45-1, Block C2, Jalan PJU 1/39,
Dataran Prima, 47301 Petaling
Jaya, Selangor, MALAYSIA
TEL: (03) 7805-3263
Roland Corporation U.S.
5100 S. Eastern Avenue
Los Angeles, CA 90040-2938,
U. S. A.
Lima - Peru
TEL: (511) 4461388
TRINIDAD
AMR Ltd
Ground Floor
Maritime Plaza
Barataria Trinidad W.I.
TEL: (868) 638 6385
TEL: (021) 285-4169
TEL: (323) 890 3700
ITALY
Roland Italy S. p. A.
Viale delle Industrie 8,
20020 Arese, Milano, ITALY
TEL: (02) 937-78300
ISRAEL
Halilit P. Greenspoon & Sons
Ltd.
8 Retzif Ha'aliya Hashnya St.
Tel-Aviv-Yafo ISRAEL
TEL: (03) 6823666
As of November 1, 2006 (ROLAND)
04564278
07-04-1N
Download from Www.Somanuals.com. All Manuals Search And Download.
|