M30262T-PTC
Converter Board for M30262
User’s Manual
Keep safety first in your circuit designs!
ꢀRenesas Technology Corporation and Renesas Solutions Corporation put the maximum effort into making semiconductor products
better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to
personal injury, fire or property damage. Remember to give due consideration to safety when making your circuit designs, with
appropriate measures such as (i) placement of substitutive, auxiliary circuits, (ii) use of nonflammable material or (iii) prevention
against any malfunction or mishap.
Notes regarding these materials
ꢀThese materials are intended as a reference to assist our customers in the selection of the Renesas Technology product best suited
to the customer's application; they do not convey any license under any intellectual property rights, or any other rights, belonging to
Renesas Technology Corporation, Renesas Solutions Corporation or a third party.
ꢀRenesas Technology Corporation and Renesas Solutions Corporation assume no responsibility for any damage, or infringement of
any third-party's rights, originating in the use of any product data, diagrams, charts, programs, algorithms, or circuit application
examples contained in these materials.
ꢀAll information contained in these materials, including product data, diagrams, charts, programs and algorithms represents information
on products at the time of publication of these materials, and are subject to change by Renesas Technology Corporation and
Renesas Solutions Corporation without notice due to product improvements or other reasons. It is therefore recommended that
customers contact Renesas Technology Corporation, Renesas Solutions Corporation or an authorized Renesas Technology product
distributor for the latest product information before purchasing a product listed herein. The information described here may contain
technical inaccuracies or typographical errors. Renesas Technology Corporation and Renesas Solutions Corporation assume no
responsibility for any damage, liability, or other loss rising from these inaccuracies or errors. Please also pay attention to information
published by Renesas Technology Corporation and Renesas Solutions Corporation by various means, including the Renesas home
page (http://www.renesas.com).
ꢀWhen using any or all of the information contained in these materials, including product data, diagrams, charts, programs, and
algorithms, please be sure to evaluate all information as a total system before making a final decision on the applicability of the
information and products. Renesas Technology Corporation and Renesas Solutions Corporation assume no responsibility for any
damage, liability or other loss resulting from the information contained herein.
ꢀRenesas Technology semiconductors are not designed or manufactured for use in a device or system that is used under
circumstances in which human life is potentially at stake. Please contact Renesas Technology Corporation, Renesas Solutions
Corporation or an authorized Renesas Technology product distributor when considering the use of a product contained herein for any
specific purposes, such as apparatus or systems for transportation, vehicular, medical, aerospace, nuclear, or undersea repeater use.
ꢀThe prior written approval of Renesas Technology Corporation and Renesas Solutions Corporation is necessary to reprint or
reproduce in whole or in part these materials.
ꢀIf these products or technologies are subject to the Japanese export control restrictions, they must be exported under a license from
the Japanese government and cannot be imported into a country other than the approved destination. Any diversion or reexport
contrary to the export control laws and regulations of Japan and/or the country of destination is prohibited.
ꢀPlease contact Renesas Technology Corporation or Renesas Solutions Corporation for further details on these materials or the
products contained therein.
Precautions to be taken when using this product
ꢀThis product is a development supporting unit for use in your program development and evaluation stages. In mass-producing your
program you have finished developing, be sure to make a judgment on your own risk that it can be put to practical use by performing
integration test, evaluation, or some experiment else.
ꢀIn no event shall Renesas Solutions Corporation be liable for any consequence arising from the use of this product.
ꢀRenesas Solutions Corporation strives to renovate or provide a workaround for product malfunction at some charge or without charge.
However, this does not necessarily mean that Renesas Solutions Corporation guarantees the renovation or the provision under any
circumstances.
ꢀThis product has been developed by assuming its use for program development and evaluation in laboratories. Therefore, it does not
fall under the application of Electrical Appliance and Material Safety Law and protection against electromagnetic interference when
used in Japan.
If the requirements shown in the "CAUTION" sentences are ignored,
the equipment may cause personal injury or damage to the products.
CAUTION
Rev.2.00
January 16, 2005
REJ10J077-0200
( 1/4 )
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Hardware Configuration of the M30262T-PTC (See Figure 3)
Hardware configuration of the M30262T-PTC is shown below.
(1) Connector
Connector for the emulator for M16C/62P (M3062PT-EPB).
(2) Cable
Flat cable which connects the user system flexibly (Length: 150 mm).
(3) Target interface
Interface which has a connector for a user system and jumper switch JP1.
Jumper switch JP1
M16C/62P TOOL SIDE
40b
40a
40b
40a
JP1
J1
J2
IC1
1
1b
1a
1b
1a
M30262T-PTC REV.A
M30262T-PTCB REV.A
Connector
Cable (FFC cable : 150 mm)
Target interface
Figure 3 Hardware configuration of the M30262T-PTC
Emulator for 16C/62P
( PC7501 + M3062PT-EPB )
( PC4701 + M3062PT3-RPD-E )
6. Connection Procedure (see Figure 4)
The procedure for connecting the M30262T-PTC is shown below.
(1) Mount the NQPACK048SD.
PC7501
(2) Mount the YQPACK048SD on the NQPACK048SD.
(3) Secure the four corners of the YQPACK048SD with
the YQ-GUIDE's.
M3062PT-EPB
M3062PT3-RPD-E
Do NOT use the screws in the YQPACK048SD package.
Do NOT use the screwdriver in the NQPACK048SD
package for securing YQ-GUIDE's (used for securing
HQPACK048SD).
(5)
(4) Attach the M30262T-PTC to the YQPACK048SD.
(5) Connect the emulator for M16C/62P to the M30262T-PTC.
(4)
Use a flat-blade
screwdriver.
7. Switch Settings
YQ-GUIDE’s
(x4)
When you use No. 36 pin (Port P15/INT3/ADTRG),
set switch JP1 according to port functions.
(3)
M30262T-PTCB
YQPACK048SD
NQPACK048SD
(2)
(1)
For ADTRG
For P15 or INT3
JP1
JP1
48-pin 0.5-mm-pitch
(48P6Q-A) foot pattern
Figure 5 JP1 Settings
Figure 4 Connection Procedure
( 3/4 )
Download from Www.Somanuals.com. All Manuals Search And Download.
8. External Dimensions of the M30262T-PTC (Connector) and a Sample Foot Pattern (see Figure 6)
10.0
6.5
30.0
JP1
0.5
0.25
IC1
1
M30262T-PTC REV.A
Unit: mm
Figure 6 External dimensions of M30262T-PTC and sample foot pattern
9. Precautions
CAUTION
Cautions for Debugging M16C/262 with an Emulator for M16C/62P:
ꢀThe cautions for software development of M16C/26 using the emulator for M16C/62P (M3062PT-EPB or
M3062PT3-RPD-E) are as follows.
(1) NMI*
M16C/26: NMI* is disabled after reset. Set the P85/NMI* function select bit (bit 4 of address 001E16) to "1" to
use the NMI* interrupt.
M16C/62P:NMI* is enabled after reset.
(2) Port P85
M16C/26: Port P85 has direction and pull-up control registers.
M16C/62P: Port P85 functions only as an input port. Thus, debugging of port P85 output and pull-up functions
cannot be performed with the M16C/62P tool.
(3) Flash memory suspend mod
M16C/62P flash memory does not support the M16C/26 suspension mode. Thus, debugging of the suspension
function cannot be performed with the M16C/62P tool.
ꢀWhen starting up a debugger (M3T-PD30F or M3T-PD30), select the following MCU file according to the emulator
for M16C/62P.
(1) When you start up the M3T-PD30F using the PC7501 + M3062PT-EPB, select “M16C62P.mcu”.
(2) When you start up the M3T-PD30 using the PC4701 + M3062PT3-RPD-E, select “M3062PT3.mcu”.
IMPORTANT
Notes on This Product:
ꢀWhen connecting the M30262T-PTC, be sure to use the included YQ-GUIDE's
ꢀDo not use the screws included with the YQPACK048SD for connecting the YQPACK048SD
ꢀWe cannot accept any request for repair.
ꢀFor purchasing the NQPACK048SD, YQPACK048SD and HQPACK048SD, contact the following:
ꢀFor inquiries about the product or the contents of this manual, contact your local distributor.
( 4/4 )
Download from Www.Somanuals.com. All Manuals Search And Download.
|