H8/3337Y Series, H8/3334 Series
TQFP-80C
User System Interface Cable
(HS3337ECN61H)
for E6000 Emulator
User’s Manual
HS3337ECN61HE(C)
Download from Www.Somanuals.com. All Manuals Search And Download.
Preface
Thank you for purchasing the E6000 emulator for the Renesas’s original microprocessor H8/300
series.
The HS3337ECN61H is a user system interface cable that connects an H8/300 series E6000
emulator (HS3008EPI60H; hereinafter referred to as the emulator) to the IC socket for a TQFP-
80C package (package code: TFP-80C) for the H8/3337Y series or H8/3334 series MCU on the
user system.
i
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Preface
.........................................................................................................i
Section 1 Configuration....................................................................................1
Section 2 Connection Procedures......................................................................4
2.1 Connecting User System Interface Cable to Emulator Station .........................................4
2.2 Connecting User System Interface Cable to User System ................................................5
2.2.1 Installing IC Socket .............................................................................................5
2.2.2 Soldering IC Socket.............................................................................................5
2.2.3 Inserting Cable Head ...........................................................................................5
2.2.4 Fastening Cable Head ..........................................................................................6
2.2.5 Connecting Cable Body to Cable Head ...............................................................8
2.3 Recommended Dimensions for User System Mount Pad .................................................9
2.4 Dimensions for User System Interface Cable Head..........................................................10
2.5 Resulting Dimensions after Connecting User System Interface Cable.............................11
Section 3 Installing the MCU to the User System.............................................12
Section 4 Verifying Operation...........................................................................14
Section 5 Notice ................................................................................................15
ii
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 1 Configuration
CAUTION
Use an IC149-080-058-B51 socket (manufactured by
YAMAICHI ELECTRONICS Co., Ltd.) for the TFP-80C package
IC socket on the user system.
Figure 1 shows the configuration of the HS3337ECN61H user system interface cable for the
TFP-80C package.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
To emulator station
Cable body
Screws (M2.6 x 12 mm)
with flat washers
Screws (M2.6 x 8 mm)
with flat washers
(for fastening cable head)
Socket cover
Cable head
IC socket
User system
Figure 1 HS3337ECN61H User System Interface Cable
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 1 lists the HS3337ECN61H components. Please make sure you have all of these
components when unpacking.
Table 1
HS3337ECN61H Components
No. Component
Quantity
Remarks
1
2
3
4
5
6
Cable body
1
1
1
1
4
4
Includes flat cable
Cable head
IC socket
For the TFP-80C package
Socket cover
For installing an TFP-80C-packaged MCU
For fastening cable head (with four flat washers)
Screws (M2.6 x 12 mm)
Screws (M2.6 x 8 mm)
For installing an TFP-80C-packaged MCU (with
four flat washers)
7
Documentation
1
User’s manual for HS3337ECN61H (this manual)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 2 Connection Procedures
2.1
Connecting User System Interface Cable to Emulator Station
WARNING
Always switch OFF the user system and the emulator
product before the USER SYSTEM INTERFACE CABLE
is connected to or removed from any part. Before connecting,
make sure that pin 1 on both sides are correctly aligned. Failure to
do so will damage the user system and the emulator product or will
result in PERSONAL INJURY. The USER PROGRAM will be
LOST.
To connect the cable body to the emulator station, follow the instructions below.
1. Make sure the user system and emulator station are turned off.
2. After making sure the direction of the cable body connector is correct, firmly insert the cable
body connector into the emulator station socket (figure 2).
Emulator station
0
0
0
6
E
Cable body
User system interface cable
Figure 2 Connecting User System Interface Cable to Emulator Station
4
Download from Www.Somanuals.com. All Manuals Search And Download.
2.2
Connecting User System Interface Cable to User System
WARNING
Always switch OFF the user system and the emulator
product before the USER SYSTEM INTERFACE CABLE
is connected to or removed from any part. Before connecting,
make sure that pin 1 on both sides are correctly aligned. Failure to
do so will damage the user system and the emulator product or will
result in PERSONAL INJURY. The USER PROGRAM will be
LOST.
To connect the cable head to the user system, follow the instructions below.
2.2.1 Installing IC Socket
After checking the location of pin 1 on the IC socket, apply epoxy resin adhesive to the bottom of
the IC socket for an TFP-80C package, and fasten it to the user system before soldering.
2.2.2
Soldering IC Socket
After fastening, solder the IC socket for an TFP-80C package to the user system. Be sure to
completely solder the leads so that the solder slops gently over the leads and forms solder fillets.
(Use slightly more solder than the MCU.)
2.2.3
Inserting Cable Head
CAUTION
Check the location of pin 1 before inserting.
Align pin 1 on the IC socket for an TFP-80C package on the user system with pin 1 on the user
system interface cable head, and insert the user system interface cable head into the IC socket on
the user system, as shown in figure 3.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
2.2.4
Fastening Cable Head
CAUTION
1. Use a Phillips-type screwdriver whose head matches
the screw head.
2. The tightening torque must be 0.294 N•m or less.
If the applied torque cannot be accurately measured,
stop tightening when the force required to turn the screw
becomes significantly greater than that needed when first
tightening. If a screw is tightened too much, the screw head
may break or an IC socket contact error may be caused by
a crack in the IC socket solder.
3. If the emulator does not operate correctly, cracks might
have occurred in the solder. Check conduction with
a tester and re-solder the IC socket if necessary.
Fasten the user system interface cable head to the IC socket for an TFP-80C package on the user
system with the four screws (M2.6 x 12 mm) provided. Each screw should be tightened a little at
a time, alternating between screws on opposing corners. Take special care, such as manually
securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by
overtightening the screws or twisting the components.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Screws (M2.6 x 12 mm), flat washer
Cable head
Pin 1
IC socket
(IC149-080-058-B51 manufactured by
YAMAICHI ELECTRONICS Co. Ltd.)
User system
Figure 3 Connecting User System Interface Cable to User System
7
Download from Www.Somanuals.com. All Manuals Search And Download.
2.2.5
Connecting Cable Body to Cable Head
Connect the cable body to the cable head.
Cable body
Removing
Push the remove jig
Remove jig
Cable head
User system
Figure 4 Fastening Cable Body
8
Download from Www.Somanuals.com. All Manuals Search And Download.
2.3
Recommended Dimensions for User System Mount Pad
Figure 5 shows the dimensions for the recommended mount pad (footprint) for the user system
with an IC socket for an TFP-80C package (IC149-080-058-B51: manufactured by YAMAICHI
ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from
those of the actual chip's mount pad.
15.10 (min.)
11.80 (max.)
0.50 19 = 9.50 0.05
0.50 0.05
0.30 0.05
Unit: mm
Figure 5 Recommended Dimensions for Mount Pad
9
Download from Www.Somanuals.com. All Manuals Search And Download.
2.4
Dimensions for User System Interface Cable Head
The dimensions for the user system interface cable head are shown in figure 6.
Unit: mm
Tolerance: –0.5 mm
Figure 6 Dimensions for User System Interface Cable Head
10
Download from Www.Somanuals.com. All Manuals Search And Download.
2.5
Resulting Dimensions after Connecting User System Interface Cable
The resulting dimensions, after connecting the user system interface cable head to the user system,
are shown in figure 7.
Cable head
IC socket
(IC149-080-058-B51
manufactured by
YAMAICHI ELECTRONICS Co. Ltd.)
User system
Unit: mm
Tolerance: –0.5 mm
Figure 7 Resulting Dimensions after Connecting User System Interface Cable
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 3 Installing the MCU to the User System
CAUTION
1. Check the location of pin 1 before inserting.
2. Use a Phillips-type screwdriver whose head matches
the screw head.
3. The tightening torque must be 0.294 N•m or less.
If the applied torque cannot be accurately measured,
stop tightening when the force required to turn the screw
becomes significantly greater than that needed when first
tightening. If a screw is tightened too much, the screw head
may break or an IC socket contact error may be caused by
a crack in the IC socket solder.
4. If the MCU does not operate correctly, cracks might have
occurred in the solder. Check conduction with a tester
and re-solder the IC socket if necessary.
Check the location of pin 1 before inserting the MCU into the IC socket on the user system, as
shown in figure 8. After inserting the MCU, fasten the socket cover with the provided four
screws (M2.6 x 8 mm). Take special care, such as manually securing the IC socket soldered area,
to prevent the IC socket from being damaged by overtightening the screws or twisting the
components.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Screws (M2.6 x 8 mm)
with flat washers
Socket cover
MCU
Pin 1
IC socket
(IC149-080-058-B51
manufactured by
YAMAICHI ELECTRONICS Co., Ltd.)
User system
Figure 8 Installing MCU to User System
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 4 Verifying Operation
1. When using the H8/300 series E6000 emulator (HS3008EPI60H), turn on the emulator
according to the procedures described in the H8/300 Series E6000 Emulator User's Manual
(HS3008EPI60HE).
2. Verify the user system interface cable connections by accessing the external memory and ports
to check the bus states of the pins. If an error is detected, recheck the soldered IC socket and
the location of pin 1.
3. The emulator connected to this user system interface cable supports two kinds of clock
sources: an emulator internal clock and an external clock on the user system. For details, refer
to the H8/300 Series E6000 Emulator User's Manual (HS3008EPI60HE).
To use the emulator internal clock
Select the clock in the emulator station as the system clock (φ), by using the CLOCK
command (emulator command).
To use the external clock on the user system as the system clock
Select target clock t or t2 with the CLOCK command (emulator command). Supply the
external clock from the user system to the emulator. Connect a crystal oscillator to the
EXTAL and XTAL terminals for the system clock. In the H8/3337Y series, the system
clock (φ) has the same frequency as the external clock, and in the H8/3334 series, the
system clock has a half frequency of the external clock.
Figure 9 shows the oscillator circuit on the user system interface cable.
Figure 9 Oscillator Circuit
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 5 Notice
1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable
head before inserting the cable head into the user system IC socket.
2. The dimensions of the recommended mount pad for the user system IC socket are different
from those of the MCU.
3. This user system interface cable is specifically designed for the HS3008EPI60H emulator. Do
not use this cable with any other emulator station.
4. To prevent breaking of wires in the cable body, do not place heavy or sharp metal objects on
the user system interface cable.
5. While the emulator station is connected to the user system with the user system interface
cable, force must not be applied to the cable head. Place the emulator station, user system
interface cable, and user system as shown in the example in figure 10.
Place components so that the cable body and cable head are
parallel to the user system.
Cable
Emulator station
Cable head is parallel
to emulator station
Cable head is parallel
to user system
User system
Figure 10 User System Interface Cable Location Example
6. The P1 short connector is used for testing. Do not remove the short pins that are inserted in
the sides of pin 1 and pin 2.
3
1
P1
Figure 11 P1 Short Connector
15