Regency Indoor Fireplace P121LC NG User Guide

Owners &  
Installation  
Zero Clearance Room  
Sealed Gas Fireplace  
STYLE  
MODEL  
SeeThru  
P121-NG  
P121-LPG  
LeftCorner  
RightCorner P121RC-NG  
Pier P131-NG  
P121LC-NG  
P121LC-LPG  
P121RC-LPG  
P131-LPG  
PLEASE KEEP THESE INSTRUCTIONS  
FOR FUTURE REFERENCE  
WARNING:  
FORYOURSAFETY  
Improper installation, adjustment, altera-  
tion, service or maintenance can cause  
injury or property damage. Refer to this  
manual. For assistance or additional infor-  
mationconsultanauthorizedinstaller,serv-  
ice agency or the gas supplier.  
What to do if you smell gas:  
Do not try to light any appli-  
ance  
LISTINGSANDCODEAPPROVALS  
Do not touch any electrical  
switch: do not use any  
phone in your building.  
Immediately call your gas  
supplierfromaneighbour's  
phone. Follow the gas sup-  
plier'sinstructions.  
If you cannot reach your  
gas supplier, call the fire  
department.  
These gas appliances have been tested in  
accordance with AS4553-2000, NZS 5262  
and have been certified by the Australian  
GasAssociationforinstallationandoperation  
as described in these Installation and  
Operating Instructions.  
FORYOURSAFETY  
Donotstoreorusegasolineorotherflamma-  
ble vapours and liquids in the vicinity of this  
or any other appliance.  
Your unit should be serviced annually  
by an authorised service person.  
Installation and service must be performed  
by an authorized installer, service agency or  
the gas supplier.  
918-179a  
02/16/06  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
Safety Label  
SafetyLabel ............................................................... 4  
Installation  
Operating Instructions  
OperatingInstructions ...............................................29  
LightingProcedure ....................................................29  
ShutdownProcedure .................................................29  
First Fire ...................................................................29  
NormalOperatingSoundsof  
Gas Appliances ..................................................29  
AerationAdjustment..................................................29  
Lighting Plate Instructions .........................................30  
ImportantMessage .................................................... 5  
Before You Start ........................................................ 5  
GeneralSafetyInformation ......................................... 5  
Installation Checklist .................................................. 5  
Specifications ............................................................ 6  
LocatingYourFireplace ............................................. 8  
Clearances ................................................................. 9  
CombustibleMantelClearances ................................. 9  
FramingandFinishing ...............................................10  
FacingandFinishingRequirements ..........................11  
Unit Assembly Prior to Installation  
TopStandoffAssembly .......................................11  
FlueingIntroduction ...................................................11  
ExteriorFlueTerminationLocations ..........................12  
Flueing: Direct Vent System (Flex) ...........................13  
Flueing: Simpson Dura-Vent Direct Vent GS .............14  
Flueing: Simpson Dura-Vent Components List ..........14  
FlueingArrangements  
Maintenance  
MaintenanceInstructions ..........................................30  
GeneralFlueMaintenance ........................................30  
LogReplacement ......................................................31  
Thermopile/Thermocouple .........................................31  
Glass Gasket............................................................31  
DoorGlass................................................................31  
Gold-PlatedAccessories...........................................31  
RemovingValve .........................................................31  
InstallingValve ..........................................................32  
PartsList  
HorizontalTerminations ......................................15  
VerticalTerminations ..........................................17  
Flueing-Dura-VentHorizontalInstallations ...............19  
Flueing-Dura-VentVerticalTermination ...................20  
Flueing - Installation Procedures for Direct Vent  
Replacement/SparePartsList...................................33  
Warranty  
System (Flex) .....................................................21  
ConveriontoLPG ......................................................22  
System Data .............................................................23  
Gas Line Installation..................................................23  
Pilot Adjustment .......................................................23  
Gas Pipe Pressure Test ............................................23  
Warranty ...................................................................39  
S.I.T.ValveDescription .............................................23  
Log Set Installation ...................................................24  
GlassDoorRemoval..................................................26  
FinishingTrim ...........................................................26  
LouversandGrills......................................................26  
RemoteControl(optional) ..........................................27  
Remote Wall Switch (optional) ..................................27  
WallThermostat(optional) ........................................27  
WiringDiagram .........................................................28  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
SAFETY LABEL  
NOTE: Regency units are constantly being  
improved. Check the label on the unit and if  
there is a difference, the label on the unit is the  
correct one.  
This is a copy of the label that accompanies  
eachREGENCYP121/P121LC/P121RC/P131  
Zero Clearance Room Sealed Gas Fireplace.  
We have printed a copy of the contents here  
for your review. The safety label is located on  
the front inside base of the unit, visible when  
the bottom louver is open.  
4
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
14) The appliance area must be kept clear and  
free of combustible materials, (gases and  
other flammable vapours and liquids).  
IMPORTANT:  
SAVE THESE  
INSTRUCTIONS  
YOUNG CHILDREN SHOULD BE  
CAREFULLY SUPERVISEDWHENTHEY  
AREINTHESAMEROOMASTHEAP-  
PLIANCE.  
Emissions from burning wood or gas could  
contain chemicals known to the State of  
California to cause cancer, birth defects or  
other reproductive harm.  
TheRegencyP121/P121LC/P121RC/P131-NG  
or P121/P121LC/P121RC/P131-LPG Room  
Sealed Gas Fireplace must be installed in ac-  
cordance AG601 and NZS 5261 and with these  
instructions. Carefully read all the instructions  
inthismanualfirst.Consultthe"authorityhaving  
jurisdiction" to determine the need for a permit  
prior to starting the installation. It is the respon-  
sibility of the installer to ensure this fireplace is  
installed in compliance with manufacturer's  
instructions and all applicable codes.  
GENERAL SAFETY  
INFORMATION  
INSTALLATION  
CHECKLIST  
1) The appliance shall be installed in accord-  
ance with the manufacturer's installation  
instructions, local gas fitting regulations,  
municipal building codes, water supply reg-  
ulations, electrical wiring regulations, with  
AS5601-2004 (AGA gas installation code)  
NZS 5261 (New Zealand)  
Note: These units are  
non-load bearing.  
1) Locate appliance  
2) See general construction and assembly  
instructions. The appliance and flue should  
be enclosed.  
a) Room location, page 8.  
b) Clearances to Combustibles,  
page 9.  
BEFORE YOU START  
Safe installation and operation of this appliance  
requires common sense, however, we are  
required to make you aware of the following:  
c) Mantle Clearances, page 9.  
d) Framing & Finishing Requirements,  
page 10.  
3) This appliance must be connected to the  
specified flue and termination cap to the  
outside of the building envelope. Never flue  
to another room or inside a building. Make  
sure that the flue is fitted as per Flueing  
instructions.  
e) Flueing Requirements, pages 11-19.  
INSTALLATIONANDREPAIRSHOULD  
BEDONEBYAAUTHORIZEDSERVICE  
PERSON.THEAPPLIANCESHOULDBE  
INSPECTED BEFORE USE AND AT  
LEASTANNUALLYBYAAUTHORIZED  
SERVICEPERSON.MOREFREQUENT  
CLEANINGMAYBEREQUIREDDUETO  
EXCESSIVELINTFROMCARPETING,  
BEDDINGMATERIAL,ETC.ITISIMPER-  
ATIVE THAT CONTROL COMPART-  
MENTS,BURNERSANDCIRCULATING  
AIR PASSAGEWAYS OF THE APPLI-  
ANCEBEKEPTCLEAN.  
2) Assemble Top Standoffs, page (NOTE:  
page11mustbedonebeforeinstallingunit  
into fireplace.)  
4) Inspect the flueing system annually for  
blockage and any signs of deterioration.  
3) Install flue, pages 19-21.  
5) Flueing terminals shall not be recessed into  
a wall or siding.  
4) Makegasconnections. Testthepilot. Must  
be as per diagram. Page 22.  
6) Any safety glass removed for servicing  
must be replaced prior to operating the  
appliance.  
5) Install log set where indicated on  
page 24-25.  
6) Glass Door Removal (page 26), Louvers  
or Grills (page 26), and Finishing Trim  
(page 26).  
7) To prevent injury, do not allow anyone who  
is unfamiliar with the operation to use the  
fireplace.  
DUE TO HIGH TEMPERATURES, THE  
APPLIANCESHOULDBELOCATEDOUT  
OFTRAFFICANDAWAYFROMFURNI-  
TUREANDDRAPERIES.  
7) Install optional Wall Switch, Remote Con-  
trol, or Wall Thermostat, page 27.  
8) Wear gloves and safety glasses for pro-  
tection while doing required maintenance.  
8) Final check.  
9) Be aware of electrical wiring locations in  
walls and ceilings when cutting holes for  
termination.  
WARNING:FAILURETOINSTALLTHIS  
APPLIANCECORRECTLYWILLVOID  
YOURWARRANTYANDMAYCAUSEA  
SERIOUSHOUSEFIRE.  
Before leaving this unit with the customer, the  
installermustensurethattheapplianceisfiring  
correctly and operation fully explained to cus-  
tomer.  
10) Under no circumstances should this appli-  
ance be modified. Parts that have to be  
removed for servicing should be replaced  
prior to operating this appliance.  
This includes:  
CLOTHINGOROTHERFLAMMABLEMA-  
TERIALSHOULDNOTBEPLACEDON  
ORNEARTHEAPPLIANCE.  
1) Clocking the appliance to ensure the cor-  
rect firing rate (rate noted on label 40,000  
Btu/h NG, and 39,000 Btu/h LPG) after  
burning appliance for 15 minutes.  
11) Installationandanyrepairstothisappliance  
should be done by a authorized service  
person. Aauthorizedservicepersonshould  
be called to inspect this appliance annually.  
Make it a practice to have all of your gas  
appliances checked annually.  
CHILDRENANDADULTSSHOULDBE  
ALERTEDTOTHEHAZARDSOFHIGH  
SURFACETEMPERATURES,ESPECIAL-  
LY THE FIREPLACE GLASS, AND  
SHOULDSTAYAWAYTOAVOIDBURNS  
ORCLOTHINGIGNITION.  
2) If required, adjusting the primary air to  
ensure that the flame does not carbon.  
First allow the unit to burn for 15-20 min.  
to stabilize.  
12) Do not slam shut or strike the glass door.  
13) Under no circumstances should any solid  
fuels (wood, paper, cardboard, coal, etc.)  
be used in this appliance.  
CAUTION: Any alteration to the product  
that causes sooting or carboning that  
results in damage is not the responsi-  
bility of the manufacturer.  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
INSTALLATION  
SPECIFICATIONS  
P121 - See Thru  
Note: These units are  
non-load bearing.  
P131 - Pier  
6
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
P121LC - Left Corner Unit  
Note: These units are  
non-load bearing.  
P121RC - Right Corner Unit  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
INSTALLATION  
LOCATING YOUR  
GAS FIREPLACE  
A) P121 - See Thru  
1) When selecting a location for your stove,  
ensure that the clearances are met as  
outlined on page 9.  
2) Provide adequate clearances for servic-  
ing.  
3) The appliance must be installed on a flat,  
solid, continuous surface (e.g. wood, met-  
al, concrete). This may be the floor, or  
raised up on a platform to enhance its visual  
impact. If the appliance is going to be in-  
stalled on carpeting, combustible linoleum  
tile or other combustible material other than  
wood flooring, the appliance must be in-  
stalled on a metal or wood panel extending  
the full width and depth of the appliance.  
4) The Room Sealed Gas Fireplace can be  
installed as follows:  
Model # Position  
P121: See Thru  
P131:Pier  
B) P131 - Pier  
A)  
B)  
C)  
D)  
P121LC: Left Corner  
P121RC:RightCorner  
5) This appliance is Listed for bedroom instal-  
lations when used with a Listed Millivolt  
Thermostat. Some areas may have further  
requirements, check local codes before  
installation.  
6) The P121/P121LC/P121RC/P131 Room  
Sealed Gas Fireplace is approved for al-  
cove installations, which meet the clear-  
ances listed on this page.  
7) We recommend that you plan your installa-  
tion on paper using exact measurements  
for clearances and floor protection before  
actually installing this appliance. Have a  
authorized inspector, dealer, or installer  
review your plans before installation.  
C) P121LC - Left Corner  
Note: For Exterior Flue Termination  
Locations see page 12.  
.
D) P121RC - Right Corner  
8
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
CLEARANCES  
The clearances listed below are Minimum distances unless otherwise stated (refer to diagrams on page 8):  
Clearance to Combustibles from:  
Back  
Side  
Floor  
0"  
0"  
0"  
(0mm)  
(0mm)  
(0mm)  
WARNING:  
Fire hazard is an extreme risk  
if these clearances (air space)  
to combustible materials are  
not adhered to. It is of greatest  
importance that this fireplace  
and flue system be installed  
only in accordance with these  
instructions.  
CAUTION REQUIREMENTS: The top, back and sides of the fireplace are defined by  
standoffs. The metal ends of the standoffs may NOT be recessed into combus-  
tible construction.  
Determine the total thickness of the finished floor (eg. tile, carpet, slate) to allow  
the finished surface to be flush with the base of the unit.  
Ceiling Height from Floor 72" (1828mm)  
Mantel Height from Base of Unit:  
39" min. (991mm)  
Horizontal Flue Clearances:  
Top  
Side  
Bottom  
2-1/2"(64mm)  
1-1/2"(38mm)  
1-1/2"(38mm)  
Vertical Flue Clearances 1-1/4" (32mm)  
COMBUSTIBLE MANTELS  
Mantel Clearances  
Because of the extreme heat this fireplace emits, the mantel clearanc-  
es are critical. Combustible mantel clearances from top of unit are shown in  
Diagram to the right.  
Note: A non-combustible mantel may be installed at a lower height if  
the framing is made of metal studs covered with a non-  
combustible board.  
This drawing is to scale at 1:6 (one inch = 6 inches)  
Mantel can be installed anywhere in shaded area or higher using this scale.  
Caution: Ensure the paint that is used on the mantel and the facing is  
"heat resistant" or the paint may discolour.  
* If the 3" (76mm) metal extension trim is removed it must be replaced with a 8"  
(203mm) non-combustible material.  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
FRAMING AND FINISHING  
1) For ease of installation, frame your fireplace after it is positioned and  
the flue system is installed. Remember to install the top standoffs.  
See page 11 for assembly. Use 2x4's and frame to local building  
codes.  
FramingDimensions  
P121 (See Thru)  
P131 (Pier)  
P121LC / P121RC  
(Corner Unit)  
A
25"(635mm)  
minus two times  
the finishing  
25"(635mm)  
minus two times  
the finishing  
26-13/13"(660mm)  
minus two times  
the finishing  
CAUTION: Verify your fireplace dimensions, framing methods  
and finished wall facing details before framing. Determine the  
total thickness of facing material - drywall plus ceramic tiles,  
slate, etc. Allow the finish surface to be flush with the front or  
side of the unit. Total facing thickness can vary from 1/2"  
(13mm) to 1-1/4" (32mm) thick.  
material thickness* material thickness* material thickness*  
B
C
42-1/2"(1080mm)  
42-1/2"(1080mm)  
42-1/2"(1080mm)  
46-3/4"(1187mm) 45" (1143mm)  
minus one time  
45"(1143mm)  
minus one time  
the finishing  
2) When locating your appliance on an exterior wall or in a chase, apply  
a vapour barrier and drywall, as per local building codes. DO NOT  
INSULATETHEFIREPLACEITSELF.  
the finishing  
material thickness* material thickness*  
CAUTION: The unit does not have to be completely enclosed in  
a chase. The clearance on top of the unit is 0" to the standoffs  
so combustible building materials can be laid directly on top of  
the standoffs. You must maintain clearance from the flue to  
combustible materials for both rigid and flex, see Flue Clear-  
ances, page 9.  
* Finish material thickness includes: drywall, ceramic tile, slate, etc.  
P121LC - Corner Unit  
P121 - See Thru  
P131 - Pier  
P121RC - Corner Unit  
C
A
B
Note: These units are  
non-load bearing.  
10  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
FACING & FINISHING REQUIREMENTS  
This fireplace is supplied with a 3" metal extension trim above the fireplace. The extension trim may be replaced if the framing is faced with a non-  
combustible material placed flush with the front and side face of the unit and extending from the top of the unit. (ie. tile, slate, etc.)  
FLUEING  
INTRODUCTION  
UNIT ASSEMBLY  
PRIOR TO  
INSTALLATION  
The P121/P121LC/P121RC/P131 uses the  
"balanced flue" technology Co Axial system.  
The inner liner flue products of combustion to  
the outside while the outer liner draws outside  
combustion air into the combustion chamber  
therebyeliminatingtheneedtouseheatedroom  
air for combustion and losing warm room air up  
the chimney.  
The 4 Top Standoffs must be correctly positioned and attached to the top before unit is slipped  
into position.  
TopStandoffAssembly  
The top standoffs are shipped in a flat position and must be folded into shape and attached.  
1) Remove the standoffs from the fireplace  
top.  
Note: These flue pipes must not be con-  
nected to any other appliance.  
2) Take each standoff and bend into the  
correct shape. Bend up at the bend lines  
until the screw holes in the standoff and the  
pre-punched screw holes on the fireplace  
top line up.  
The gas appliance and flue system must be  
flueeddirectlytotheoutsideofthebuilding, and  
never be attached to a chimney serving a  
separate solid fuel or gas burning appliance.  
Each direct flue gas appliance must use it's  
own separate flue system. Common flue sys-  
tems are prohibited.  
3) Attach the standoff securely to the top with  
4 screws per standoff (on opposite cor-  
ners).  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
EXTERIOR FLUE TERMINATION LOCATIONS  
Minimum clearances required for balanced flue terminals or  
the flue terminals of outdoor appliances  
according to AS5601-2004 (AGA gas installation code) or NZS 5261 (New Zealand)  
Minimum  
Clearance (mm)  
a
Below eaves, balconies or other projections:  
- Appliances up to 50 MJ/h input  
- Appliances over 50 MJ/h input  
From the ground or above a balcony  
From a return wall or external corner  
From a gas meter (M)  
From an electricity meter or fuse box (P)  
From a drain or soil pipe  
300  
500  
300  
500  
1000  
500  
150  
b
c
d
e
f
g
Horizontal from any building structure (unless appliance is approved  
for closer installation) or obstruction facing a terminal  
From any other flue terminal, cowl or combustion air intake  
Horizontally from an openable window, door, or non-mechanical air inlet, or  
any other opening into a building, with the exception of sub-floor ventilation  
(see also Note (I)):  
500  
500  
h
j
- Appliances up to 150 MJ/h input  
500  
- Appliances over 150 MJ/h input  
1500  
k
Vertically below an openable window, door, or non-mechanical air inlet,  
or any other opening into a building, with the exception of sub-floor ventilation  
(see also Note (I)): see table below  
Clearance 'k' in mm  
Space Heaters  
All Other Appliances  
Up to 50 MJ/h  
input  
Up to 50 MJ/h input Over 50 MJ/h input Over 150 MJ/h input  
to 150 MJ/h input  
150  
500  
1000  
1500  
NOTES:  
(I) For mechanical air inlets, including spa blowers, the clearance 'j' and 'k' shall be 1500 mm in all cases.  
(II) All distances shall be measured vertically or horizontally along the wall to a point in line with the nearest  
par to of the terminal.  
(III) Prohibited area below electricity meter or fuse box extends to ground level.  
(IV)A flue terminal of this type shall not be located under a roofed area unless the roofed area is fully open on  
at least two sides and a free flow of air at the appliance is achieved.  
12  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
FLUEING ARRANGEMENT - HORIZONTAL TERMINATIONS  
Regency Direct Vent System (Flex) Horizontal Terminations Only  
These flueing systems, in combination with the P121/P121LC/P121RC/P131 Direct Vent Gas Fireplace, have been tested and listed as a direct flue  
heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram  
on page 12.  
Regency Direct Vent (Flex) System Termination Kit (Part# 946-513) includes all the parts needed to install the P121/P121LC/P121RC/  
P131 with a maximum run of 2 feet.  
1) 6-7/8" dia. flexible liner (2 ft. length)  
2) 4" dia. flexible liner (2 ft. length)  
3) spring spacers (3)  
4) thimble (2)  
5) AstroCap termination cap (1)  
6) screws (12)  
7) tube of Mill Pac (1)  
8) plated screws (8)  
9) screws #8 x 1-1/2" drill point, stainless steel (4)  
Notes:  
1) Liner sections should be continuous without any joints or seams.  
2) Only Flex pipe purchased from Regency may be used for Flex installations.  
3) Regency Direct Vent System (Flex) is only approved for horizontal terminations.  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
INSTALLATION  
SIMPSON DURA-VENT FLUEING  
Horizontal or Vertical Terminations  
The Simpson Dura-Vent Direct Vent System offers a complete line of component parts for installation of both horizontal and vertical installations.  
Many items are offered in decorative black, as well as galvanized finish. We recommend using the galvanized finish for installation with the P121/  
P121LC/P121RC/P131.  
The minimum components required for a  
basic horizontal termination are:  
vinyl siding standoff, to  
create a level surface to  
mount the vent terminal.  
The Terminal must not be  
recessedintosiding.Meas-  
ure the wall thickness in-  
cluding furring strips.  
1
1
1
1
1
1
Simpson Duravent Adaptor  
Horizontal Termination Cap  
45o Elbow  
Flue Adaptor  
WallThimble  
Length of pipe to suit wall thickness  
(see chart)  
If a Vinyl Siding Standoff is  
required (it must be used  
with vinyl siding), measure  
to outside surface of wall  
without siding and add 2  
inches.  
Wall thickness is measured from the back  
standoffs to the inside mounting surface of  
termination cap. For siding other than vinyl  
furring strips may be used, instead of the  
Flat Wall Installation  
Wall Thickness  
(inches)  
Vent Length  
Required (inches)  
4" - 5-1/2"  
7" - 8-1/2"  
10" - 11-1/2"  
9" - 14-1/2"  
15" - 23-1/2"  
6"  
9"  
12"  
11" - 14-5/8" Adj. Pipe  
17" - 24" Adj. Pipe  
The Regency AstroCapTM is certified for installations using FPI  
venting systems as well as Simpson Dura-Vent® and Direct  
Vent GS.  
RegencyTM, and Regency AstroCapTM are the proprietary trade-  
marks of FPI Fireplace Products International Ltd.  
Simpson  
Dura-Vent® and Direct Vent GS are registered and/or propri-  
etary trademarks of Simpson Dura-Vent Co. Inc.  
Dura-Vent  
Direct Vent GS  
SIMPSON DURA-VENT FLUEING COMPONENTS LIST  
All Simpson Dura-Vent components are available directly from Regency.  
Part # Description  
Part # Description  
902 48" Pipe Length - Galv.  
902B 48" Pipe Length - Black  
911B 11"-14 5/8" Adjustable Pipe Length -  
Black  
Part # Description  
982 Snorkel - 14" Rise Termination Cap  
981 Snorkel - 36" Rise Termination Cap  
940 Wall Thimble - Support/Box  
941 Cathedral/Ceiling - Support/Box  
3951 Brass Trim for Wall Thimble/Ceiling Sup.  
963 Firestop Spacer  
943 Flashing 0/12-6/12  
943S Flashing 7/12-12/12  
953 StormCollar  
950 Vinyl Siding Standoff  
988 Wall Strap  
971  
Horiz.TerminationKit includes:  
90o black elbow, wall thimble cover, horiz.  
square termination cap, 24" black pipe, and 11"  
-14" 5/8" adjustable black pipe  
970  
Basic Horiz. Termination. Kit includes:  
90o black elbow, wall thimble cover,  
horiz. square termination cap  
917B 17"- 24" Adjustable Length - Black  
945  
45O Elbow - Galv.  
945B 45O Elbow - Black  
978  
Vert. Termination Kit includes 0/12 -  
6/12 pitch adjustable flashing, storm  
collar, low profile term. cap  
945G 45O Elbow - Swivel - Galv.  
945BG 45O Elbow - Swivel - Black  
990  
90O Elbow - Galv.  
908B 6" Pipe Length - Black  
907B 9" Pipe Length - Black  
990B 90O Elbow - Black  
990G 90O Elbow - Swivel - Galv.  
942 WallThimble  
Parts not supplied by Dura-Vent  
906  
906B 12" Pipe Length - Black  
904 24" Pipe Length - Galv.  
904B 24" Pipe Length - Black  
903 36" Pipe Length - Galv.  
12" Pipe Length - Galv.  
990BG 90O Elbow - Swivel - Black  
946-506/P  
510-994  
640-530/P  
946-205  
Vent Guard (Optional)  
Dura-Vent Flue Adaptor  
Riser Vent Terminal  
Vinyl Siding Shield for Riser  
Vent Terminal  
991  
980  
984  
985  
High Wind Termination Cap (Vertical)  
Vertical Termination Cap  
Horizontal Square Termination Cap  
Horiz. Square High Wind Termination  
Cap  
903B 36" Pipe Length - Black  
946-206  
AstroCap Standoff  
14  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
FLUEING ARRANGEMENTS - HORIZONTAL TERMINATIONS  
SIMPSON DURA-VENT DIRECT VENT GS SYSTEM (LPG & NG)  
The diagram below shows examples of horizontal termination arrangements using one, two, or three 90o elbows (two 45o elbows equal one 90o  
elbow).  
Note:  
1) A maximum of three 90o elbows are permitted.  
2) Minimum distance between elbows is 1 ft. (305mm).  
Simpson Dura-Vent  
4" inner diameter  
6-5/8" outer diameter  
Maintain clearances to combustibles as listed on page 9.  
Horizontal flue must be supported every 3 feet.  
Firestops are required at each floor level and whenever passing through a wall.  
Must use optional flue adapter (Part# 510-994) when using Simpson Dura-Vent pipe.  
A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes.  
Horizontal Flueing with One (1) 90o Elbow  
Straight Out Horizontal Flueing  
Option  
A)  
V
H
1' (305mm) Minimum  
2' (610mm) Minimum  
3' (914mm) Minimum  
4' (1.22m) Minimum  
5' (1.5m) Minimum  
6' (1.86m) Minimum  
3' (914mm) Maximum  
6' (1.86m) Maximum  
9' (2.7m) Maximum  
12' (3.6m) Maximum  
15' (4.5m) Maximum  
17' (5.1m) Maximum  
B)  
C)  
D)  
E)  
F)  
With the above options, maximum total pipe length if 37 feet with  
minimumof6feettotalverticalandmaximum17feettotalhorizontal.  
Please note minimum 1 foot between 90o elbows is required.  
Diagram 1  
Diagram 2  
Please note the minimum centerline  
for basic install shown above.  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  
INSTALLATION  
Horizontal Flueing with Three (3) 90o Elbows  
Horizontal Flueing with Two (2) 90o Elbows  
Option  
A)  
V
H
H + H1 + H2  
Option  
A)  
V
H + H1  
2' (610mm) Min. 1' (305mm) Max. 3'(914mm)Max.  
3' (914mm) Min. 3' (914mm) Max. 6' (1.86m) Max.  
4' (1.22mm) Min. 5' (1.5m) Max.  
1' (305mm) Minimum  
2' (610mm) Minimum  
3' (914mm) Minimum  
4' (1.22m) Minimum  
5' (1.5m) Minimum  
6' (1.86m) Minimum  
2' (610mm) Maximum  
5' (1.5m) Maximum  
8' (2.4m) Maximum  
11' (3.35m) Maximum  
14' (4.27m) Maximum  
15' (4.5m) Maximum  
B)  
C)  
D)  
B)  
C)  
D)  
E)  
9' (2.7m) Max.  
5' (1.5m) Min. 7' (2.13m) Max. 12' (3.6m) Max.  
With the above options, maximum total pipe length if 37 feet with  
minimum of 5 feet total vertical and maximum 12 feet total horizontal.  
Please note minimum 1 foot between 90o elbows is required.  
F)  
With the above options, maximum total pipe length if 37 feet with  
minimum of 6 feet total vertical and maximum 15 feet total horizontal.  
Please note minimum 1 foot between 90o elbows is required.  
Diagram 5  
Horizontal Flueing with Three (3) 90o Elbows  
Diagram 3  
Option  
A)  
V + V1  
H + H1  
2' (610mm) Minimum  
3' (914mm) Minimum  
4' (1.22m) Minimum  
5' (1.5m) Minimum  
3' (914mm) Maximum  
6' (1.86m) Maximum  
9' (2.7m) Maximum  
12' (3.6m) Maximum  
B)  
C)  
D)  
Horizontal Flueing with Two (2) 90o Elbows  
Option  
A)  
V
H
H + H1  
With the above options, maximum total pipe length if 37 feet with  
minimum of 5 feet total vertical and maximum 12 feet total horizontal.  
Please note minimum 1 foot between 90o elbows is required.  
1' (305mm) Min. 1' (305mm) Max. 3'(914mm)Max.  
2' (610mm) Min. 3' (0.91m) Max. 6' (1.86m) Max.  
B)  
C)  
D)  
3' (914mm) Min. 5' (1.5m) Max.  
5' (1.5m) Min. 8' (2.4m) Max.  
9' (2.7m) Max.  
12' (3.6m) Max.  
With the above options, maximum total pipe length if 37 feet with  
minimum of 5 feet total vertical and maximum 12 feet total horizontal.  
Please note minimum 1 foot between 90o elbows is required.  
Diagram 4  
Diagram 6  
16  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
FLUEING ARRANGEMENTS - VERTICAL TERMINATIONS  
SIMPSON DURA-VENT DIRECT VENT GS SYSTEM (LPG & NG)  
Flue must be supported at offsets  
Maintain clearances to combustibles as listed on page 9.  
Firestops are required at each floor level and whenever passing through a wall.  
Must use optional flue adapter when using Simpson Dura-Vent pipe (Part# 510-994).  
The P121/P121LC/P121RC/P131 is approved for a maximum 35 ft. (10.7m) straight vertical, with Simpson Dura-Vent Direct Vent GS flue systems  
for LPG and NG, as per diagram 7 below.  
Vertical Flueing with One (1) 90o Elbow  
Straight Up Vertical Flueing  
Option  
A)  
V
H
1' (305mm) Minimum  
2' (610mm) Minimum  
3' (914mm) Minimum  
4' (1.22m) Minimum  
2' (610mm) Maximum  
4' (1.22m) Maximum  
6' (1.86m) Maximum  
8' (2.4m) Maximum  
B)  
C)  
D)  
With the above options, maximum total pipe length if 37 feet with  
minimum of 4 feet total vertical and maximum 8 feet total horizontal.  
Please note minimum 1 foot between 90o elbows is required.  
Diagram 7  
Diagram 8  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
17  
INSTALLATION  
Vertical Flueing with Two (2) 90o Elbows  
Vertical Flueing with Two (2) 90o Elbows  
Option  
A)  
V
H
Option  
A)  
V
H + H1  
1' (305mm) Minimum  
2' (610mm) Minimum  
3' (914mm) Minimum  
4' (1.22m) Minimum  
5' (1.5m) Minimum  
6' (1.86m) Minimum  
4' (1.22m) Maximum  
6' (1.86m) Maximum  
9' (2.7m) Maximum  
12' (3.6m) Maximum  
15' (4.5m) Maximum  
17' (5.1m) Maximum  
1' (305mm) Minimum  
2' (610mm) Minimum  
3' (914mm) Minimum  
4' (1.22m) Minimum  
2' (610mm) Maximum  
4' (1.22m) Maximum  
6' (1.86m) Maximum  
8' (2.4m) Maximum  
B)  
C)  
D)  
E)  
B)  
C)  
D)  
With the above options, maximum total pipe length if 37 feet with  
minimum of 4 feet total vertical and maximum 8 feet total horizontal.  
Please note minimum 1 foot between 90o elbows is required.  
F)  
With the above options, maximum total pipe length if 37 feet with  
minimum of 6 feet total vertical and maximum 17 feet total horizontal.  
Please note minimum 1 foot between 90o elbows is required.  
Diagram 9  
Diagram 10  
Vertical Flueing with Three (3) 90o Elbows  
Option  
A)  
V + V1  
H
H + H1  
2' (610mm) Min. 1' (305mm) Max. 2' (610mm) Max.  
3' (914mm) Min. 4' (1.22m) Max. 5' (1.5m) Max.  
4' (1.22mm) Min. 6' (1.86m) Max. 8' (2.4m) Max.  
B)  
C)  
D)  
5' (1.5m) Min.  
8' (2.4m) Max.  
12' (3.6m) Max.  
With the above options, maximum total pipe length if 37 feet with  
minimum of 5 feet total vertical and maximum 12 feet total horizontal.  
Please note minimum 1 foot between 90o elbows is required.  
Diagram 11  
18  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
Vertical Flueing with Three (3) 90o Elbows  
Option  
A)  
V + V1  
H + H1  
2' (610mm) Minimum  
3' (914mm) Minimum  
4' (1.22m) Minimum  
5' (1.5m) Minimum  
3' (914mm) Maximum  
6' (1.86m) Maximum  
9' (2.7m) Maximum  
12' (3.6m) Maximum  
B)  
C)  
D)  
With the above options, maximum total pipe length if 37 feet with  
minimum of 5 feet total vertical and maximum 12 feet total horizontal.  
Please note minimum 1 foot between 90o elbows is required.  
Diagram 12  
gram 1. Push the pipe sections com-  
HORIZONTAL  
INSTALLATIONS  
pletely together, then twist-lock one  
section clockwise approximately one-  
quarter turn, until the two sections are  
fullylocked. Thefemalelockinglugswill  
not be visible from the outside, on the  
Black Pipe or fittings. They may be  
located by examining the inside of the  
female ends.  
Install the flue system according to the  
manufacturer's instructions included  
with the components.  
1) Set the unit in its desired location. Check to  
determine if wall studs or roof rafters are in  
the way when the flueing system is at-  
tached. If this is the case, you may want to  
adjust the location of the unit. Rough in the  
gas.  
Diagram 2  
2) Direct Flue pipe and fittings are designed  
with special twist-lock connections to con-  
nect the flueing system to the appliance flue  
outlet. A twist-lock appliance adaptor is an  
available option that must be used in con-  
junction with the Simpson Dura-Vent Direct  
Vent GS system.  
Note:  
a) The horizontal run of flue must be level,  
or have a 1/4 inch rise for every 1 foot  
of run towards the termination. Never  
allow the flue to run downward. This  
could cause high temperatures and  
may present the possibility of a fire.  
Diagram 1  
Note: Apply sealant "Mill-Pac" to inner  
pipe and high temperature sili-  
cone sealant to outer pipe on eve-  
ry twist-lock joint.  
3) Putabeadofsiliconeinsidetheoutersection  
of the adapter and a bead of Mill Pac on the  
inner collar. Slip the adapter over the exist-  
ing inner and outer flue collar and fasten to  
the outer collar only with the 3 supplied  
screws (drilling pilot holes will make this  
easier). Level the fireplace and fasten it to  
the framing using nails or screws through  
the nailing strips.  
b) Thelocationofthehorizontalfluetermi-  
nation on an exterior wall must meet all  
local and national building codes, and  
must not be blocked or obstructed. For  
External Flue Terminal Locations, see  
diagram on page 12.  
b) Horizontal runs of flue must be sup-  
ported every three feet. Wall straps are  
available for this purpose.  
5) Mark the wall for a 10" x 10" square hole.  
Thecenterofthesquareholeshouldlineup  
with the centerline of the horizontal pipe.  
Cutandframethe10inchsquareholeinthe  
exterior wall where the flue will be termi-  
nated. If the wall being penetrated is con-  
structed of non-combustible material, i.e.  
masonry block or concrete, a 7"(178mm)  
dia. (7-1/2"(191mm) dia. for flex) hole is  
acceptable.  
6) The arrow on the flue cap should be  
pointing up. Insure that the 1-1/2" clear-  
ances to combustible materials are main-  
tained (Diagram 3 on page 16). Install the  
termination cap.  
4) Assemble the desired combination of pipe  
and elbows to the appliance adaptor and  
twist-lock for a solid connection.  
Note:  
The four wood screws provided should be  
replaced with appropriate fasteners for  
stucco, brick, concrete, or other types of  
sidings.  
a) Twist-lockprocedure:Fourindentations,  
located on the female ends of pipes and  
fittings, are designed to slide straight  
ontothemaleendsofadjacentpipesand  
fittings, by orienting the four pipe inden-  
tations so they match and slide in to the  
four entry slots on the male ends, Dia-  
Note: With Dura-Vent, the minimum height  
is achieved by installing a 45o elbow di-  
rectly to the flue adaptor.  
Note: If installing termination on a siding  
covered wall, a vinyl siding stand-  
off or furring strips must be used  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
19  
INSTALLATION  
4) Assemble the desired lengths of pipe and  
elbows. Ensure that all pipes and elbow  
connections are in the fully twist-locked  
position and sealed.  
VERTICAL  
TERMINATION  
1) Maintain the 1-1/4" clearances (air  
spaces) to combustibles when  
passing through ceilings, walls,  
roofs, enclosures, attic rafter, or  
other nearby combustible surfac-  
es. Do not pack air spaces with  
insulation. Check pages 17-19 for  
the maximum vertical rise of the  
flueing system and the maximum  
horizontal offset limitations.  
5) Cut a hole in the roof centered on the small  
drilled hole placed in the roof in Step 2. The  
hole should be of sufficient size to meet the  
minimumrequirementsforclearancetocom-  
bustibles of 1-1/4". Slip the flashing under  
the shingles (shingles should overlap half  
the flashing) as per Diagram 4.  
Diagram 3  
2) Set the gas appliance in  
its desired location. Drop  
a plumb bob down from  
the ceiling to the position  
of the appliance flue exit,  
and mark the location  
to ensure that the termination is  
not recessed into the siding.  
7) Before connecting the horizontal run of flue  
pipe to the flue termination, slide the Wall  
Thimble (Part # 942) over the flue pipe.  
Diagram 1  
where the flue will pene-  
tratetheceiling.Drillasmallholeathispoint.  
Diagram 4: The upper half of the flashing is  
installed under the roofing material and not  
nailed down until the chimney is installed.  
This allows for small adjustments.  
8) Slide the appliance and flue assembly to-  
wards the wall carefully inserting the flue  
pipe into the flue cap assembly. It is impor-  
tant that the flue pipe extends into the flue  
cap sufficient distance so as to result in a  
minimum pipe overlap of 1-1/4 inches. Se-  
cure the connection between the flue pipe  
and the flue cap by attaching the two sheet  
metal strips extending from the flue cap  
assembly into the outer wall of the flue pipe.  
Use the two sheet metal screws provided  
toconnectthestripstothepipesection. See  
Diagram 4.  
Next, drop a plumb bob from the roof to the  
hole previously drilled in the ceiling, and  
mark the spot where the flue will penetrate  
the roof. Determine if ceiling joists, roof  
rafters or other framing will  
obstruct the flueing system.  
You may wish  
6) Continue to assemble pipe lengths.  
Note: If an offset is necessary in the attic  
to avoid obstructions, it is impor-  
tant to support the flue pipe every  
3 feet, to avoid excessive stress  
on the elbows, and possible sep-  
aration. Wall straps are available  
for this purpose (Diagram 2).  
to relocate the  
appliance or to  
offset,  
as  
shown in Dia-  
gram 2 to avoid  
cutting  
load  
bearing mem-  
bers.  
9) Install wall thimble in the center of the 10"  
square and attach with wood screws (Di-  
agram 5).  
Galvanized pipe is desirable above the roof-  
line due to its higher corrosion resistance.  
Continue to add pipe sections through the  
flashing until the height of the flue cap meets  
theminimumheightrequirementsspecifiedin  
Diagram 5 or local codes. Note that for steep  
Diagram 2  
Note: Apply sealant "Mill-Pac" to inner  
pipe and high temperature sili-  
cone sealant to outer pipe on eve-  
ry twist-lock joint.  
Diagram 5  
3) A Firestop spacer must be installed in the  
floor or ceiling of every level. To install the  
Firestop spacer in a flat ceiling or wall, cut  
a 10 inch square hole. Frame the hole as  
shown in Diagram 3 and install the firestop.  
Roof Pitch  
Minimum Vent Height  
Feet  
2
Meters  
0.61  
0.61  
0.61  
0.76  
0.99  
1.22  
1.52  
1.83  
2.13  
2.29  
2.44  
flat to 7/12  
over 7/12 to 8/12  
over 8/12 to 9/12  
over 9/12 to 10/12  
over 10/12 to 11/12  
over 11/12 to 12/12  
over 12/12 to 14/12  
over 14/12 to 16/12  
over 16/12 to 18/12  
over 18/12 to 20/12  
over 20/12 to 21/12  
2
Diagram 4  
2
2.5  
3.25  
4
5
6
7
7.5  
8
Diagram 5  
Diagram 3  
20  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
roof pitches, the vertical height must be  
increased. A poor draft, or down drafting can  
result from high wind conditions near big  
trees or adjoining roof lines, in these cases,  
increasing the flue height may solve the  
problem.  
inside each other and can be adjusted for  
2 x 4 or 2 x 6 walls. The liners must slip  
over the collars a minimum of 1-3/8".  
Note: To make the  
installation more  
aesthetically pleas-  
ing, we recom-  
mend framing out a  
square to mount  
the terminal to.  
5) Slip the assembled liner and termination  
assembly through the thimble making sure  
the termination cap faces up (there are  
markings on the cap that show which way  
is up). This will position the termination cap  
with proper down slope for draining water.  
Fasten the cap to the outer wall with the 4  
supplied screws.  
7) Ensure flue is vertical and secure the base  
of the flashing to the roof with roofing rails,  
slide storm collar over the pipe section and  
seal with a mastic.  
8) Install the vertical termination cap by twist-  
be used to ensure that the termi-  
nation is not recessed into the  
siding.  
locking it.  
6) Pull the centre 4"(100mm) liner and outer  
6-7/8"(175mm) liner out enough to slip over  
the flue collars of the fireplace. (You may  
wish to cut the liner shorter to make it more  
workable.) Do not bend liner more than 45o.  
Note: Any closets or storage spaces,  
which the flue passes through  
must be enclosed.  
2) Level the fireplace and fasten it to the  
framing using nails or screws through the  
nailing strips.  
7) Apply Mill Pac over the fireplace inner collar  
and slip the 4"(100mm) liner down over it  
and attach with 3 supplied screws.  
OffsetChart  
3) AssembletheflueassemblybyapplyingMill  
Pac to the 4"(100mm) inner collar of the  
terminationand slippingthe4"(100mm)liner  
over it at least 1-3/8" (35mm). Fasten with  
the 3 screws (drilling pilot holes will make  
this easier). Apply Mill Pac or high temper-  
aturesiliconetothe6-7/8"(175mm)flexpipe  
and slip it over the 6-7/8" outer collar of the  
flue terminal at least 1-3/8"(35mm) and fas-  
ten with the 3 screws.  
8) Do the same with the 6-7/8"(175mm) liner.  
9) Apply a bead of silicone between the thim-  
ble and termination and around the outer  
edge of the terminal at the wall in order to  
keep the water out.  
IMPORTANT: Do not locate termination  
hood where excessive snow or ice build-  
up may occur. Be sure to check flue termi-  
nation area after snow falls, and clear to  
prevent accidental blockage of flueing  
system. When using snow blowers, make  
sure snow is not directed towards flue  
termination area.  
NOTE: Horizontal sections must be sup-  
ported at intervals not exceeding 3  
feet (0.9 meter). (Flame picture and  
performance will be affected by  
sags in the liner).  
4) Separatethe2halvesofthewallthimbleand  
securely fasten the one with the tabs to the  
outside wall making sure that the tabs are  
on top and bottom. Fasten the other thimble  
halftotheinsidewall.Thethimblehalvesslip  
INSTALLATION  
PROCEDURES  
for Regency AstroCapTM Direct  
Flue System (Flex)  
1) Locate the unit in the framing, rough in the  
gas. Locate the centerline of the termina-  
tion and mark wall accordingly. Cut a  
10"(254mm) hole in the wall (inside dimen-  
sion).  
Note: A 1-1/2"(38mm) clearance around  
the liner must be maintained ex-  
cept that only a 1" (25mm) clear-  
ance is needed at the termination  
end. We recommend framing a  
10"(254mm) x 10"(254mm) (inside  
dimensions) hole to give struc-  
tural rigidity for mounting the ter-  
mination.  
Note: If installing termination on a siding  
covered wall, furring strips must  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
21  
INSTALLATION  
CONVERSION KIT FROM NG TO LPG MODEL #730-969  
FOR P121/P121LC/P121RC/P131 USING SIT 820 NOVA GAS VALVE  
THIS CONVERSION MUST BE DONE BY A AUTHORIZED GAS FITTER  
IF IN DOUBT DO NOT DO THIS CONVERSION !!  
5) Remove pilot inner  
box by removing the  
2 screws.  
Conversion Kit Contains:  
Qty. Part # Description  
1
910-018 SIT Conversion Kit-50%  
Turndown LPG  
1
1
1
1
1
910-037 LPG Injector (Pilot Orifice)  
*
Burner Orifice #50  
908-255 Decal "Converted to LPG"  
908-529 5/32" Allen Key  
918-032 Instruction Sheet  
6) Pull off the pilot  
cap to expose the  
pilot orifice.  
1) Removethelouversandtrimkit.Removethe  
front door.  
2) Remove the logs, embers.  
3) Remove the grate by lifting straight up.  
Remove the side brick panels (if installed).  
The brick panel is very fragile - handle  
with care.  
7) Unscrew the pilot orifice with the allen key  
and replace with the LPG pilot orifice in the  
kit and replace pilot cap.  
8) Re-install pilot inner box using 2 screws.  
4) Remove the burner assembly by removing  
the 4 Phillips head screws and then slide  
the burner assembly away from the orifice  
and lift out.  
9) Remove burner orifice with a 1/2" spanner  
and discard. Use another spanner to hold  
on to the elbow behind the orifice.  
14) Attach clear label "This unit has been con-  
verted to LPG" near or on the serial # decal.  
Attach white label "This valve has been  
converted from NG to LPG using SIT con-  
versionKit Code0.907.202"ontothevalve.  
Burner Orifice  
10) Reinstall new burner orifice LPG stamped  
#50 and tighten.  
Diagram 1: Remove the left and right  
screws and then slide the burner assembly  
away from the orifice and lift out.  
15) Replace yellow "NG" label with red "LPG"  
label  
11) Remove and discard the 3 pressure regu-  
lator mounting screws (A), pressure regu-  
lator tower (B) and diaphragm (C).  
16) Check for gas leaks.  
17) Check inlet and outlet pressures.  
18) Check operation of flame control.  
12) Insure that the rubber gasket (D) is properly  
positioned and install the new HI/LO pres-  
sure regulator assembly to the valve using  
the new screws (E) supplied with the kit.  
Tighten screws securely.  
19) Check for proper flame appearance and  
glow on logs.  
13) Reverse steps 4) to 1).  
22  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
Important: Always check for gas leaks  
with a soap and water solution or gas  
leak detector. Do not use open flame for  
leak testing.  
Note: To properly check gas pressure,  
both inlet and manifold pressures  
should be checked using the valve  
pressure ports on the valve.  
P121/P121LC/P121RC/P131-NG  
System Data  
For 0 to 4500 feet altitude  
Burner Inlet Orifice Sizes: #31  
Pilot Orifice NG  
1) Makesurethevalveisinthe"OFF"position.  
2) Loosen the "IN" and/or "OUT" pressure  
tap(s), turning counterclockwise with a  
1/8" wide flat screwdriver.  
PILOT ADJUSTMENT  
Max. Input Rating 42 mj.  
Min. Input Rating 22 mj.  
3) Attach manometer to "IN" and/or "OUT"  
Supply Pressure min. 1.13 kPa  
pressure tap(s) using a 5/16" ID hose.  
Manifold Pressure  
4) Light the pilot and turn the valve to "ON"  
(High)  
1.00 kPa  
position.  
Log Set: Ceramic fibre, 8 per set.  
5) The pressure check should be carried out  
with the unit burning and the setting should  
be within the limits specified on the safety  
label.  
Flue System: Regency AstrocapTM, Re-  
gency Direct Vent System (Flex) and Simp-  
son Dura-Vent Direct Flue System  
Periodically check the pilot flames. Cor-  
rect flame pattern has three strong blue  
flames: 1 flowing around the thermopile,  
1 around the thermocouple and 1 flowing  
across the burner (it does not have to be  
touching the burner).  
6) When finished reading manometer, turn off  
the gas valve, disconnect the hose and  
tighten the screw (clockwise) with a 1/8"  
flat screwdriver. Note: Screw should be  
snug, but do not over tighten.  
P121/P121LC/P121RC/P131-LPG  
System Data  
For 0 to 4500 feet altitude  
Burner Inlet Orifice Sizes: #50  
Pilot Orifice LPG  
Note: If you have an incorrect flame pat-  
tern, contact your Regency dealer  
for further instructions.  
S.I.T. VALVE DESCRIPTION  
Max. Input Rating 41 mj.  
Min. Input Rating 22 mj.  
1) Gas cock knob  
2) Manual high/low adjustment  
3) Pilot Adjustment  
4) Thermocouple Connection - option  
5) Outlet Pressure Tap  
6) Inlet Pressure Tap  
7) PilotOutlet  
Incorrect flame pattern will have small,  
probably yellow flames, not coming into  
proper contact with the rear burner or  
thermopile or thermocouple.  
Supply Pressure min. 3.00 kPa  
Manifold Pressure  
(High)  
2.65 kPa  
8) Main Gas Outlet  
9) Alternative TC Connection  
Point  
Log Set: Ceramic fibre, 8 per set.  
Flue System: Regency AstrocapTM, Re-  
gency Direct Vent System (Flex) and Simp-  
son Dura-Vent Direct Flue System  
GAS LINE  
INSTALLATION  
The gas line can be brought through either the  
right,theleftside orthebottomoftheappliance.  
The gas valve is situated on the bottom of the  
unit.  
GAS PIPE PRESSURE  
TESTING  
The gas line connection may be made of rigid  
pipe, copper pipe or an approved flex connec-  
tor. (If you are using rigid pipe, ensure that the  
valve can be removed for servicing.) Since  
somemunicipalitieshaveadditionallocalcodes  
it is always best to consult with your local  
authorities and AS5601-2004 (Australian  
Installation Code) NZS 5261(New Zealand  
Installation Standard).  
The appliance must be isolated from the gas  
supply piping system by closing its individual  
manual shut-off valve during any pressure  
testing of the gas supply piping system at test  
pressures equal to or less than 3.45 kPa.  
Disconnect piping from valve at pressures over  
3.45 kPa.  
The manifold pressure is controlled by a regu-  
lator built into the gas control, and should be  
checked at the pressure test point.  
When using copper or flex connectors use  
only approved fittings. Always provide a union  
so that gas lines can be easily disconnected for  
servicing. Flare nuts for copper lines and flex  
connectors are usually considered to meet this  
requirement.  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
23  
INSTALLATION  
1) Carefully remove the logs from the box and unwrap them. The logs  
LOG INSTALLATION  
are fragile, handle with care - do not force into position.  
Read the instructions below carefully and refer to the dia-  
grams. If logs are broken do not use the unit until they are  
replaced. Broken logs can interfere with the pilot operation.  
2) Place Log 326 on the front right side of the burner. Ensure that the  
notches on the far right side of the log fit into the grate posts. Push  
back side of the left end of the log up against the tab on the burner.  
Log Kit # 360-930 contains the following pieces:  
a) 326  
b) 327  
c) 328  
d) 329  
e)  
Front Right Log  
Front Left Log  
Middle Right Log  
Middle Left Log  
Embers  
902-326  
902-327  
902-328  
902-329  
902-154  
326  
Please note that there are 2 of each log. This  
log set is mirrored front and back.  
Push back side of the left end of the log up  
against the tab on the burner.  
327  
Repeat step 2 on the opposite side of the burner.  
326  
328  
329  
326  
326  
The 3-digit numbers (ie. 327) are  
molded into the rear of each log.  
The image below shows all of the logs in place.  
3) Place Log 327 on the front left side of the burner. Position the right  
end of the log in between the two tabs and the left end of the log into  
the grate post.  
327  
328  
326  
329  
327  
Tab on Burner  
Grate Post  
327  
329  
326  
328  
24  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
Repeat step 3 on the opposite side of the burner.  
Repeat step 5 on the opposite side of the burner.  
329  
327  
327  
329  
4) Embers should be placed in front of Log 326 and Log 327 and also  
down the middle between the logs as shown in the image below.  
6) Place Log 328 on the middle right side of the burner. Ensure that the  
log fits over the 2nd grate post from the right.  
328  
Caution: Do NOT cover burner ports.  
Grate Post  
Repeat step 6 on the opposite side of the burner.  
5) Place Log 329 on the middle left side of the burner. Rest the bottom  
of the Log onto the second grate post from the left. Ensure that the  
log fits into a pin that is on Log 326.  
328  
328  
329  
326  
Place Log 329 onto pin.  
Grate Post  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
25  
INSTALLATION  
GLASS DOOR  
REMOVAL  
LOUVERS & GRILLS  
FINISHING TRIM  
1) Attach the screws provided to the top left  
and right corners.  
1) SlidetheSideFinishingTrimupintotheslot  
in the top flange of the fireplace. Push tight  
against the magnet at the base of the unit.  
1) Remove the 8 screws that secure the  
glass door.  
NOTE: Do not tighten the screw entirely,  
ensure that some room is left to be able  
to hang the grill or louver over the screw.  
Slide Trim into  
slot.  
2) Hang the Top Louver or Grill onto the 2  
screws in the top fireplace opening.  
2) Pull the door slightly out on an angle and  
then lift up and pull completely out.  
Push trim tight  
against magnet.  
3) Attach the Bottom Louver or Grill to the  
hingesonthebottomflangeofthefireplace.  
2) Slide the Corner Finishing Trim up into the  
slot in the top flange of the fireplace. Push  
tight against the magnet at the base of the  
unit.  
P121 & P131 Corner Models  
Slide Trim into  
slot.  
4) Attach the screws provided to the top and  
bottom, left and right corners similar to step  
1.  
5) Hang the top and bottom louver or grill onto  
the screws in the top and bottom, left and  
right sides of the fireplace opening.  
3) P131 & P121LC/P121RC Corner Model:  
Remove the 6 screws that secure the  
glass door and repeat step 2.  
Push trim tight  
against magnet.  
The Top and Bottom Side Louver or Grill is  
installed the same way.  
26  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
Option 1:  
Option 3:  
Option 2:  
REMOTE CONTROL  
WALL THERMOSTAT  
WALL SWITCH  
Can be used with Option 2 or 3  
but not both.  
Can be used with Option 1 or 3  
but not both.  
Can be used with Option 1 or 2  
but not both.  
Use the Regency Remote Control Kit approved  
for this unit. Use of other systems may void your  
warranty.  
1) Run the supplied 4.5m of wire through the  
back gas inlet opening. Be careful not to  
damage wire.  
A wall thermostat may be installed if desired,  
connect the wires as per the wiring diagram.  
Use the table below to determine the maximum  
wire length.  
The remote control kit comes with a hand held  
transmitter, a receiver and a wall mounting  
plate.  
Note: We recommend a maximum of  
4.5m of wire but if you wish to go  
with a longer run, use the Thermo-  
stat Wire Table.  
Note: Preferable if the thermostat is in-  
stalled on an interior wall.  
1) Choose a convenient location on the wall to  
install the receiver and the receptacle box  
(protection from extreme heat is very im-  
portant). Run wires from the fireplace to  
that location. Use the Thermostat Wire Ta-  
ble.  
Regencyoffersanoptionalprogrammablether-  
mostat but any 250-750 millivolt rated non-  
anticipator type thermostat that is CSA, ULC or  
UL approved may be used.  
2) Connect the wire to the supplied wall switch  
and install into the receptacle box.  
CAUTION  
Do not connect millivolt  
wall switch wire to a 240V wire.  
CAUTION  
2) Connect the two wires to the gas valve.  
Do not connect millivolt  
wall thermostat wires  
to a 240V wire.  
See diagram below.  
Thermostat Wire Table  
Recommended Maximum Lead Length  
(Two-Wire) When Using Wall  
Thermostat (CP-2 System)  
Wire Size  
Max. Length  
CAUTION  
Do not connect millivolt remote  
control wires to a 240V wire.  
14 GA.  
16 GA.  
18 GA.  
20 GA.  
22 GA.  
15.0 M.  
10.0 M.  
6.0 M.  
3.6 M.  
2.7 M.  
3) Install3AAAalkalinebatteriesintransmitter  
and 4 AA alkaline batteries in the receiver.  
Install the receiver and its cover in the wall.  
Switch the remote receiver to "remote"  
mode. The remote control is now ready for  
operation.  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
27  
INSTALLATION  
WIRING DIAGRAM  
No electrical power supply is required for the  
gas control to operate.  
Caution: Ensure that the wires do  
not touch any hot surfaces and are  
away from sharp edges.  
(Do not cut the ground terminal off under  
any circumstances.)  
ON-OFF SWITCH  
(910-138) BLACK  
Lockwasher  
~
Star washer  
#8 Ground Lug  
(for mobile home)  
910-610 BLACK  
910-802 BLACK  
1
WHITE  
FAN 2  
FAN 1  
~
TERMINAL  
BLOCK  
Nut  
FROM  
POWER LIVE  
Pilot  
Assembly  
NEUTRAL  
POWER  
Ground Wire  
(WIRE SUPPLY & INSTALL BY OTHERS)  
BLACK  
Grounding Lug Detail  
2
CONVECTION AIR  
TEMPERATURE SWITCH  
DC Spark  
Box  
(THERMO DISC - NORMALLY OPEN)  
Ground  
(To THTP)  
Brown  
White  
F
Gas  
In  
ON  
OFF  
Orange  
Yellow  
Burner  
(To TH)  
To Thermocouple IN  
"S.I.T" Valve  
ON OFF  
Remote Receiver  
or Thermostat  
(Millivolt) (Optional)  
Remote Transmitter  
(Optional)  
CAUTION:  
Label all wires  
Terminal Block Location  
prior to disconnection when  
servicing controls. Wiring er-  
rors can cause improper and  
dangerous operation.  
Terminal Block  
Remove cover to  
access Terminal  
Block  
28  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
SHUTDOWN  
PROCEDURE  
OPERATING  
NORMAL OPERATING  
SOUNDS OF GAS  
APPLIANCES  
INSTRUCTIONS  
1) Read and understand these instructions  
before operating this appliance.  
1) Turn OFF the flame switch.  
2) Check to see that all wiring is correct and  
It is possible that you will hear some sounds  
from your gas appliance. This is perfectly  
normal due to the fact that there are various  
gauges and types of steel used within your  
appliance. Listed below are some examples. All  
are normal operating sounds and should  
not be considered as defects in your appliance.  
2) Pushingascontrolknobslightlyandturnto"OFF"  
position.  
enclosed to prevent possible shock.  
3) Check to ensure there are no gas leaks.  
FIRST FIRE  
4) Make sure the glass in the door frame is  
properly positioned. Never operate the ap-  
pliance with the glass removed.  
DO NOT BURN THE APPLIANCE  
WITHOUT THE GLASS FRONT IN  
PLACE.  
Blower:  
5) Verify that the flueing and cap are unob-  
Regency gas appliances use high tech blow-  
ers to push heated air farther into the room. It is  
not unusual for the fan to make a "whirring"  
sound when ON. This sound will increase or  
decrease in volume depending on the speed  
setting of your fan speed control.  
structed.  
6) Ensure that the brick panels are installed.  
The first fire in your stove is part of the paint  
curing process. To ensure that the paint is  
properly cured, it is recommended that you burn  
your fireplace for at least four (4) hours the first  
time before you use it with the fan on.  
7) Verify log placement. If the pilot cannot be  
seen when lighting the unit, the logs have  
been incorrectly positioned.  
Burner Tray:  
The burner tray is positioned directly under the  
burner tube(s) and logs and is made of a  
different gauge material from the rest of the  
firebox and body. Therefore, the varying thick-  
nesses of steel will expand and contract at  
slightly different rates which can cause "tick-  
ing" and "cracking" sounds. You should also be  
aware that as there are temperature changes  
within the unit these sounds will likely re-occur.  
Again, this is normal for steel fireboxes.  
8) The unit should never be turned off, and on  
again without a minimum of a 60 second  
wait.  
When first operated, the unit will release an  
odour caused by the curing of the paint, the  
burning off of any oils remaining from manufac-  
turing. Smoke detectors in the house may go off  
at this time. Open a few windows to ventilate the  
room for a couple of hours.  
Note: When the glass is cold and the  
appliance is lit, it may cause con-  
densation and fog the glass. This  
condensation is normal and will  
disappear in a few minutes as the  
glass heats up.  
Blower Thermodisc:  
When this thermally activated switch turns ON  
it will create a small "clicking" sound. This is the  
switch contacts closing and is normal.  
Pilot Flame:  
Whilethepilotflameisonitcanmakeaveryslight  
"whisper" sound.  
During the first few fires, a white film  
may develop on the glass front as part of  
the curing process. The glass should be  
cleaned after the unit has cooled down  
or the film will bake on and become very  
difficult to remove. Use a non-abrasive  
cleaner and DO NOT ATTEMPT TO CLEAN  
THE GLASS WHILE IT IS HOT.  
Gas Control Valve:  
As the gas control valve turns ON and OFF, a  
dullclickingsoundmaybeaudible,thisisnormal  
operation of a gas regulator or valve.  
LIGHTING  
PROCEDURE  
Unit Body/Firebox:  
Different types and thicknesses of steel will  
expand and contract at different rates resulting  
in some "cracking" and "ticking" sounds will be  
heard throughout the cycling process.  
AERATION  
ADJUSTMENT  
The burner aeration is factory set. Adjustment  
may be needed due to the local gas supply or  
altitude. As a general rule if the flame is too  
yellow open up the air shutter, if it is too blue  
close the air shutter.  
NG  
LPG  
10mm open  
10mm open  
Gas Inlet  
NOTE: This adjustment is only to be made  
by an authorised person.  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
29  
OPERATING INSTRUCTIONS  
COPY OF THE LIGHTING PLATE INSTRUCTIONS  
MAINTENANCE  
INSTRUCTIONS  
FORYOURSAFETYREADBEFORELIGHTING  
1) Always turn off the gas valve before  
cleaning. For relighting, refer to lighting  
instructions. Keep the burner and control  
compartment clean by brushing and vacu-  
uming at least once a year. When cleaning  
the logs, use a soft clean paint brush as the  
logs are fragile and easily damaged.  
This appliance must be installed in accordance with local codes, if any; if not, follow the  
current CAN1-B149/ANSI Z 223.1 (Australia: AS5601-2004, New Zealand: NZS 5261)  
WARNING: If you do not follow these instructions exactly, a fire or  
explosion may result causing property damage, personal injury or loss  
oflife.Improperinstallation,adjustment,alteration,serviceormaintenance  
can cause injury or property damage. Refer to the owner’s information  
manual provided with this appliance. For assistance or additional  
information consult a qualified installer, service agency or gas supplier.  
2) Cleanapplianceanddoorwithadampcloth  
(never when unit is hot). Never use an  
abrasive cleaner. The glass should be  
cleaned with a gas fireplace glass cleaner.  
The glass should be cleaned when it  
starts looking cloudy.  
A)This appliance has a pilot which C)Use only your hand to push in or turn  
must be lighted by hand. When  
lighting the pilot, follow these  
instructions exactly.  
the gas control knob. Never use tools.  
If the knob will not push in or turn by  
hand, don’t try to repair it, call a  
qualified service technician. Force or  
attempted repair may result in a fire  
or explosion.  
3) The heater is finished in a heat resistant  
paint and should only be refinished with  
heat resistant paint. Regency uses Stove-  
Bright Paint - Metallic Black #6309.  
B)BEFORE LIGHTING smell all around  
the appliance area for gas. Be sure  
to smell next to the floor because  
some gas is heavier than air and D)Do not use this appliance if any part  
4) Make a periodic check of burner for proper  
position and condition. Visually check the  
flame of the burner periodically, making  
sure the flames are steady; not lifting or  
floating. If there is a problem, call a author-  
ized service person.  
will settle on the floor.  
has been under water. Immediately  
call a qualified service technician to  
inspect the appliance and to replace  
any part of the control system and any  
gas control which has been under  
water.  
WHAT TO DO IF YOU SMELL GAS  
- Do not try to light any appliance  
- Do not touch any electric switch, do  
not use any phone in your building  
- Immediately call your gas supplier  
5) The appliance and flueing system must be  
inspected before use, and at least annual-  
ly, by a authorized field service person, to  
ensure that the flow of combustion and  
ventilation air is not obstructed.  
from a neighbours phone. Follow This appliance needs fresh air for safe  
the gas supplier’s instructions. operation and must be installed so there  
- If you cannot reach your gas are provisions for adequate combustion  
supplier, call the fire department. and ventilation air.  
CAUTION:Hotwhileinoperation.Donottouch.SevereBurnsmayresult.Due  
tohighsurfacetemperatureskeepchildren,clothingandfurniture,gasoline  
and other liquids having fammable vapors away. Keep burner and control  
compartment clean. See installation and operating instructions  
accompanyingappliance.  
Note: Never operate the appliance with-  
out the glass properly secured in  
place.  
6) Do not use this appliance if any part has  
been under water. Immediately call a au-  
thorized service technician to inspect the  
appliance and to replace nay part of the  
control system and any gas control which  
has been under water.  
LIGHTINGINSTRUCTIONS  
STOP! Read the safety information above on this label.  
1) Push in gas control knob slightly and turn to “PILOT” position.  
2) Push in control knob all the way and hold in until the pilot lights up. Continue  
to hold the control knob in for about 20 seconds after the pilot is lit. Release  
knob.  
7) In the event this appliance has been serv-  
iced check that the flue-air system has  
been properly resealed & reinstalled in  
accordance with the manufacturer's in-  
structions.  
3) Push in gas control knob slightly and  
Gas Inlet  
turn to "ON" position.  
8) Verify operation after servicing.  
4) Turn ON the flame switch.  
General Flue Maintenance  
TO TURN OFF GAS APPLIANCE  
Conduct an inspection of the flueing system  
semi-annually.Recommendedareastoinspect  
as follows:  
You may shut off the pilot during prolonged non use periods to conserve fuel.  
1) Turn OFF the flame switch.  
1) Check the Flueing System for corrosion in  
areas that are exposed to the elements.  
These will appear as rust spots or streaks,  
and in extreme cases, holes. These com-  
ponents should be replaced immediately.  
2) Push in gas control knob slightly and turn to "OFF" position.  
DO NOT REMOVE THIS INSTRUCTION PLATE  
918-253a  
30  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
2) Remove the Cap, and shine a flashlight  
down the Flue. Remove any bird nests, or  
other foreign material.  
REMOVING VALVE  
GLASS GASKET  
1) Shut off the gas supply.  
If the glass gasket requires replacement use  
a tadpole glass gasket (Part # 936-155).  
3) Check for evidences of excessive con-  
densation, such as water droplets forming  
intheinnerliner,andsubsequentlydripping  
out the joints, Continuous condensation  
can cause corrosion of caps, pipe, and  
fittings. It may be caused by having exces-  
sive lateral runs, too many elbows, and  
exterior portions of the system being ex-  
posed to cold weather.  
2) Removethelouversandtrimkit.Removethe  
front door.  
3) Remove the logs, embers.  
DOOR GLASS  
4) Remove the grate by lifting straight up.  
Your Regency fireplace is supplied with high  
temperature 5mm-Tempered glass & 5mm-Ce-  
ramic glass. If your glass requires cleaning, we  
recommend using an approved glass cleaner  
available at all authorized dealers. Do not use  
abrasive materials.  
4) Inspect joints, to verify that no pipe sections  
or fittings have been disturbed, and conse-  
quently loosened. Also check mechanical  
supports such as Wall Straps, or plumbers'  
tape for rigidity.  
CAUTION&WARNINGS:  
* Do not clean when the glass is hot.  
* Theuseofsubstituteglasswillvoidallproduct  
warranties.  
* Care must be taken to avoid breakage of the  
glass.  
* Do not strike or abuse the glass.  
* Do not operate this fireplace without the glass  
front or with a cracked or broken glass front.  
* Wear gloves when removing damaged or  
broken glass.  
* Replacement of the glass panels should be  
done by a licensed or authorized service per  
son.  
LOG REPLACEMENT  
5) Remove the side brick clip in the top of the  
firebox and then slide the Side Brick Panel  
out. The brick panels are very fragile  
- handle with care.  
Theunitshouldneverbeusedwithbrokenlogs.  
Turn off the gas valve and allow the unit to cool  
before opening door and carefully remove the  
logs. (The pilot light generates enough heat to  
burn someone.) If for any reason a log should  
need replacement, you must use the proper  
replacement log. The position of these logs  
must be as shown in the diagrams under Log  
Installation.  
Note: Improper positioning of logs may  
create carbon build-up and will  
severely alter the unit's perform-  
ance which is not covered under  
warranty.  
GLASSREPLACEMENT  
In the event that you break your glass by impact,  
purchase your replacement from an authorized  
Regency dealer only. Replacement glass is  
shipped already installed into the door frame.  
Reinstall as per Glass Door Installation on page  
22.  
THERMOPILE/  
THERMOCOUPLE  
REPLACEMENTPARTS:  
6) Remove the burner by removing the 4  
screws.  
Front Door - Tempered (Part# 360-528)  
Side Door - Tempered (Part# 360-529)  
Front Door - Ceramic (Part# 360-538)  
Side Door - Ceramic (Part# 360-539)  
1) OpentheBottomLouversorGrills.Remove  
the Top Louver or Grill.  
2) Remove the Trim Kit, Glass Door, Log Set,  
Grate and Burner Assembly (see page 26).  
3) Disconnect thermocouple by loosening nut  
from the valve with a 9mm spanner. Dis-  
connect thermopile by loosening 2 screws  
marked TP on the valve.  
GOLD-PLATED  
ACCESSORIES  
The 24 carat gold-plated finish requires little  
maintenance, and need only be cleaned with a  
damp cloth. DO NOT use abrasive materials or  
chemical cleaners, as they may harm the finish  
and void the warranty. Clean any finger-  
prints off before turning the unit on.  
4) Remove 2 screws from the pilot assembly  
and pull up far enough to be able to loosen  
thethermocoupleorthermopilewitha7/16"  
spanner. NOTE: the pilot line is very fragile,  
use caution when pulling it up.  
7) Slide the burner assembly away from the  
orifice and lift out.  
5) Drop the thermocouple or thermopile down  
through the extrusion and pull it out of the  
unit.  
6) Reinstall the new ones in reverse order.  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
31  
MAINTENANCE  
8) Remove the Side Base Brick Panels and 13) Undo the pilot tube from the valve with a  
INSTALLING VALVE  
finally the Long Base Brick Panels.  
7/16" spanner.  
14) Undo the quick drop out thermocouple nut  
on the valve with a 9mm (metric) spanner.  
1) Attach the valve to the valve bracket with  
the 6 (m5x8 metric) screws provided.  
15) Remove the Piezo igniter wire and push  
button assembly.  
2) Reconnect the "gas out" flare fitting with an  
11/16" spanner.  
16) Undo the "gas out" flare nut with a 13/16"  
spanner.  
3) Reconnect the "gas out" flare nut with a 13/  
16" spanner.  
17) Undo the "gas out" flare fitting with an  
11/16" spanner.  
4) Install piezo ignitor push button assembly  
and reconnect wire.  
Remove Left & Right Side Base  
Brick Panels  
18) Removethe6Phillipsheadscrewsfromthe  
sides of the valve bracket and remove  
valve.  
5) Reconnectthequickdropoutthermocouple  
nut with a 9mm spanner.  
6) Reconnect the pilot tube nut with a 7/16"  
Hint: If you are using black pipe, ensure  
that there is a union by the valve,  
otherwise removal will be almost  
impossible.  
spanner.  
7) Scrape off the old gasket from the floor of  
the firebox and from the valve tray assem-  
bly.  
8) Install a new gasket and reinstall the valve  
tray assembly.  
Note: Failure to install a new gasket may  
severely affect the appliance perform-  
ance.  
Remove the 2 Long Base Brick Panels  
9) Reinstall the 16 hold down screws.  
9) Disconnect the inlet gas line.  
10) Hook up the 2 TP and 2 TH wires to the  
appropriate connections on the valve.  
10) Disconnect the 2 TP wires and the 2 TH  
wires from the valve.  
11) Reinstall the Burner Assembly.  
11) Remove the 16 Phillips head screws secur-  
ing the valve tray.  
13) Hookupthegaslineandcheckforgasleaks  
with a soap and water solution or a gas leak  
detector. (Do not use open flame for leak  
testing.)  
14) Fire up the unit temporarily  
15) Check the manifold pressure.  
16) Reinstallthelogs, grate andbrickpanelsas  
needed.  
17) Reinstall the glass doors.  
18) Fire up the unit again and check for proper  
flame appearance.  
12) Lift the entire assembly out.  
32  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS LIST  
P121 (SEE THRU) MAIN ASSEMBLY  
Part #  
Description  
Part #  
Description  
Part #  
Description  
1) 360-528 Door Assy Front - Tempered  
360-538 Door Assy Front - Ceramic  
(Optional)  
181) *  
Extension Trim - See Thru  
135) 360-069 Heat Shield - Side  
204) 360-940 Dec. Grill Front - Black (set)  
146) 360-035 FinishingTrim  
150) 360-123 Magnet Bracket - Front  
151) 904-258 Magnet  
2) 360-529 Door Assy Side - Tempered  
360-539 Door Assy Side - Ceramic  
(Optional)  
205) 948-216 Regency Logo Plate  
206) 910-172 Fan Axial 240V  
207) 910-142 Thermodisc  
168) 360-068 Door Cover Assembly - Side  
9) 360-046 Nailing Strip - Top - Front  
10) 360-047 Nailing Strip - Top - Side  
11) 430-001 Standoff - Top  
918-179 Manual  
171) 360-920 Louver Front - Black (set)  
360-922 Louver Front - Black/Gold (set)  
360-924 Louver Front - Black/Steel (set)  
360-926 Louver Front - Black/Brass (set)  
*Not available as a replacement part.  
17) 360-086 Gasket - Relief Door  
24) *  
Relief Door Assembly  
32) 902-296 Brick Panel - Base - Front  
33) 902-297 Brick Panel - Base - Side  
34) 902-298 Brick Panel - Side  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
33  
PARTS LIST  
P131 (PIER) MAIN ASSEMBLY  
Part #  
Description  
Part #  
Description  
Part #  
Description  
1) 360-528 Door Assy Front - Tempered  
360-946 Door Assy Front - Ceramic  
(Optional)  
141) 360-031 ColumnFinishingTrim  
146) 360-035 FinishingTrim  
181) *  
Extension Trim - Pier  
204) 360-940 Dec. Grill Front - Black (set)  
206) 910-172 Fan Axial 240V  
2) 360-529 Door Assy Side - Tempered  
360-948 Door Assy Side- Ceramic  
(Optional)  
149) 360-122 Magnet Bracket - Corner  
150) 360-123 Magnet Bracket - Front  
151) 904-258 Magnet  
224) 360-942 Dec. Grill Side - Black (set)  
225) 948-216 Regency Logo Plate  
226) 910-142 Thermodisc  
9) 360-046 Nailing Strip - Top - Front  
10) 360-047 Nailing Strip - Top - Side  
11) 430-001 Standoff - Top  
171) 360-920 Louver Front - Black (set)  
360-922 Louver Front - Black/Gold (set)  
360-924 Louver Front - Black/Steel (set)  
360-926 Louver Front - Black/Brass (set)  
918-179 Manual  
*Not available as a replacement part.  
17) 360-086 Gasket - Relief Door  
24) *  
Relief Door Assembly  
173) 360-932 Louver Side - Black (set)  
360-934 Louver Side - Black/Gold (set)  
360-936 Louver Side - Black/Steel (set)  
360-938 Louver Side - Black/Brass (set)  
32) 902-296 Brick Panel - Base - Side  
33) 902-297 Brick Panel - Base - Front  
34) 902-298 Brick Panel - Side  
34  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS LIST  
P121RC (RIGHT CORNER) MAIN ASSEMBLY  
Part #  
Description  
Part #  
Description  
Part #  
Description  
181) *  
Extension Trim  
1) 360-528 Door Assy Front - Tempered  
360-538 Door Assy Front - Ceramic  
(Optional)  
35) 902-300 Brick Panel - Front  
204) 360-940 Dec. Grill Front - Black (set)  
206) 910-172 Fan Axial 240V  
224) 360-942 Dec. Grill Side - Black (set)  
138) 360-063 Heat Shield - Front  
141) 360-031 ColumnFinishingTrim  
2) 360-529 Door Assy Side - Tempered  
360-539 Door Assy Side - Ceramic  
(Optional)  
146) 360-035 Finishing Trim - Left Side  
225) 948-216 Regency Logo Plate  
226) 910-142 Thermodisc  
149) 360-122 Magnet Bracket - Corner  
150) 360-123 Magnet Bracket - Front  
151) 904-258 Magnet  
9) 360-046 Nailing Strip - Top - Front  
10) 360-047 Nailing Strip - Top - Side  
11) 430-001 Standoff - Top  
918-179 Manual  
158) 360-060 Door Cover Assembly-Front  
*Not available as a replacement part.  
780-013 Standoff - Rear  
17) 360-086 Gasket - Relief Door  
171) 360-920 Louver Front - Black (set)  
360-922 Louver Front - Black/Gold (set)  
360-924 Louver Front - Black/Steel (set)  
360-926 Louver Front - Black/Brass (set)  
173) 360-932 Louver Side - Black (set)  
360-934 Louver Side - Black/Gold (set)  
360-936 Louver Side - Black/Steel (set)  
360-938 Louver Side - Black/Brass (set)  
24) *  
Relief Door Assembly  
32) 902-296 Brick Panel - Base - Side  
33) 902-297 Brick Panel - Base - Front  
34) 902-298 Brick Panel - Side  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
35  
PARTS LIST  
P121LC (LEFT CORNER) MAIN ASSEMBLY  
Part #  
Description  
Part #  
Description  
Part #  
Description  
204) 360-940 Dec. Grill Front - Black (set)  
206) 910-172 Fan Axial 240V  
224) 360-942 Dec. Grill Side - Black (set)  
138) 360-069 Heat Shield - Front  
1) 360-528 Door Assy Front - Tempered  
360-538 Door Assy Front - Ceramic  
(Optional)  
141) 360-031 ColumnFinishingTrim  
146) 360-035 FinishingTrim  
225) 948-216 Regency Logo Plate  
226) 910-142 Thermodisc  
2) 360-529 Door Assy Side - Tempered  
360-539 Door Assy Side - Ceramic  
(Optional)  
149) 360-122 Magnet Bracket - Corner  
150) 360-123 Magnet Bracket - Front  
151) 904-258 Magnet  
918-179 Manual  
9) 360-046 Nailing Strip - Top - Front  
10) 360-047 Nailing Strip - Top - Side  
11) 430-001 Standoff - Top  
*Not available as a replacement part.  
158) 360-062 Door Cover Assembly-Front  
171) 360-920 Louver Front - Black (set)  
360-922 Louver Front - Black/Gold (set)  
360-924 Louver Front - Black/Steel (set)  
360-926 Louver Front - Black/Brass (set)  
173) 360-932 Louver Side - Black (set)  
360-934 Louver Side - Black/Gold (set)  
360-936 Louver Side - Black/Steel (set)  
360-938 Louver Side - Black/Brass (set)  
17) 360-086 Gasket - Relief Door  
24) *  
Relief Door Assembly  
32) 902-296 Brick Panel - Base - Side  
33) 902-297 Brick Panel - Base - Front  
34) 902-298 Brick Panel - Side  
35) 902-300 Brick Panel - Front  
36  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS LIST  
P121/P121LC/P121RC/P131 BURNER ASSEMBLY & LOG SET  
Part #  
Description  
360-930  
41) 904-326  
42) 904-327  
43) 904-328  
44) 904-329  
Log Set  
Front Right Log  
Front Left Log  
Middle Left Log  
Middle Right Log  
360-574/P  
56) 360-378/P  
Valve Assembly  
Valve S.I.T. - NG  
57) 360-090  
58) *  
Gasket - Valve Tray  
Valve Tray  
66) 910-038  
Pilot Assembly - NG  
67) *  
PilotHolder  
68) W840470  
69) 910-190  
Pilot Assembly Gasket  
Piezo Ignitor and Nut  
79) 360-525  
82) 360-027  
904-690  
Burner Assembly  
Grate Assembly  
Orifice #31 - NG  
Orifice Gasket  
936-170  
83) 910-073  
84) 910-074  
Spark Generator Battery Holder  
Spark Generator Switch c/w Wire  
90) 910-386  
91) 910-341  
Thermocouple  
Thermopile  
*Not available as a replacement part.  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
_____________________________________________________________________________________  
____________________________________________________________  
__________________________________________________________  
____________________________________________________________  
_______________________________________________________  
_____________________________________________________  
__________________________________________________________  
_________________________________________________________  
_________________________________________________________  
______________________________________________________  
______________________________________________________  
_______________________________________________________________  
___________________________________________________________  
__________________________________________________________  
____________________________________________________________  
____________________________________________________________  
____________________________________________________________  
_____________________________________________________________  
__________________________________________________________  
__________________________________________________________  
_____________________________________________________  
________________________________________________________  
_________________________________________________________  
_________________________________________________________  
38  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY  
Regency Fireplace Products are designed with relia-  
bility and simplicity in mind. In addition, our internal  
Quality Assurance Team carefully inspects each unit  
thoroughly before it leaves our door. Regency Indus-  
tries Ltd. is pleased to extend this limited lifetime  
warranty to the original purchaser of a Regency Prod-  
uct.  
Exclusions:  
ThislimitedLifetimeWarrantydoesnotextendtoorinclude  
paint, door or glass gasketing or trim. It does not cover  
installationandoperationalrelatedproblemssuchasover-  
firing,downdraftsorspillagecausedbyenvironmentalcon-  
ditions,nearbytrees,buildings,hilltops,mountains,inade-  
quate flueing or ventilation, excessive offsets, negative air  
pressures caused by insufficient make up air, mechanical  
systems such as furnaces, fans, clothes dryers etc.  
The warranty does not extend to any part or parts which  
showevidenceofmisuseorabuse,neglect,accidentorlack  
ofmaintenance.  
Products made by other manufacturers and used in con-  
junctionwiththeoperationofthisappliancewithoutauthor-  
ization from Regency, may nullify your warranty on this  
product.  
Regency Industries Ltd., shall in no event be liable for any  
special, indirect consequential damages of any nature  
whatsoever which are in excess of the original purchase  
priceoftheproduct. Anyalterationtotheunitwhichcauses  
sootingorcarbonningthatresultsindamagetotheexterior  
facia is not the responsibility of Regency Industries Ltd.  
The Warranty: Lifetime  
Coveredundertheagreementarethefollowingcomponents:  
Combustionchamber, heatexchanger, burnertubes, logs,  
embers, glass (thermal breakage) and all gold plating  
(againstdefectivemanufacture).  
Theabovewillbecoveredforpartsandlabourforthefirstfive  
years and parts only thereafter.  
Electrical components such as fans, switches, wiring,  
thermodiscs, remote control, thermopiles, thermocouples  
and gas valves are covered for one year from the date of  
purchase.  
Conditions:  
All installations must be performed by an authorised gas  
fitter and installed according to all applicable local and  
nationalcodes. Also,allserviceworkmustbecarriedoutby  
an authorised gas service person. It is the responsibility of  
theinstallertoensurethattheapplianceisfiringasperrating  
plate. Any part or parts of this unit which in our judgement  
showevidenceofsuchdefectwillberepairedorreplacedat  
Regency'soption,throughanaccrediteddistributororagent  
providedthatthedefectivepartbereturnedtothedistributor  
or agent Transportation Prepaid, if requested. In areas  
wherethereisnotanapprovedserviceagentortheclosest  
approvedserviceagentissituatedmorethantwenty-five(25)  
kilometres from the installation, Australian Heating Distrib-  
utors are not obliged to arrange warranty repairs and travel  
and/or additional labour charges will apply.  
General:  
It is essential that all submitted claims provide all of the  
necessary information including purchase date, serial #,  
type of unit and part or parts requested.  
DISTRIBUTORS:  
Western Australia  
Eastern Australia  
AUSTRALIANHEATINGDISTRIBUTORS  
FIREPLACEPRODUCTSAUSTRALIAPTY.LTD.  
31CLUNESTREET  
21-23 SOUTH LINK BLVD.  
BAYSWATER, WA 6053  
DANDENONG,VIC3175  
SERVICEAGENTS:  
HEARTHHOUSE SERVICE  
31CLUNESTREET  
BAYSWATER, WA 6053  
NOTE:PLEASE RETAINYOURINVOICEASPROOFOFPURCHASEFORWARRANTYVERIFICATION  
INCORRECTINSTALLATIONORGASPRESSURESETTINGSARENOTCOVEREDBYWARRANTY  
A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES.  
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
39  
Printed in Canada  
© Copyright 2006, FPI Fireplace Products International Ltd. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Radio Shack Clock ACR 326 User Guide
RBH Sound Speaker WM 24 User Guide
Regalo Toddler Furniture 5006 User Guide
Ricoh All in One Printer GX3000S User Guide
Ricoh Fax Machine Fax22 User Guide
RIDGID Saw AC99402 User Guide
Rinnai Water Heater 16e User Guide
Samsung TV VCR Combo Colour TV VCR User Guide
Sanyo Camcorder VPC HD100 User Guide
Scientific Atlanta VCR VCR Commander User Guide