Regency Fire Pit IG34 LPG User Guide

Owners &  
Installation  
IG34 GAS INBUILT  
Models: IG34-NG  
IG34-LPG  
IG34-ULPG  
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE  
REFERENCE  
WARNING:  
FOR YOUR SAFETY  
Improper installation, adjustment, altera-  
tion, service or maintenance can cause  
injury or property damage. Refer to this  
manual. For assistance or additional in-  
formation consult an authorised installer,  
service agency or the gas supplier.  
What to do if you smell gas:  
Do not try to light any appli-  
ance  
Do not touch any electri-  
cal switch: do not use any  
phone in your building.  
Immediately call your gas  
supplierfromaneighbour's  
phone. Follow the gas sup-  
plier's instructions.  
If you cannot reach your  
gas supplier, call the re  
department.  
LISTINGS AND CODE APPROVALS  
FOR YOUR SAFETY  
These gas appliances have been tested in  
accordance with AS4553, NZS 5262 and  
have been certied by the Australian Gas  
Association for installation and operation as  
described in these Installation and Operating  
Instructions.  
Do not store or use gasoline or other am-  
mable vapours and liquids in the vicinity of  
this or any other appliance.  
Installation and service must be performed  
by an authorised installer, service agency or  
the gas supplier.  
Your unit should be serviced annually by  
an authorised service person.  
918-793a  
04/28/09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
MAINTENANCE  
DATA BADGE  
Copy of Data Badge .....................................................4  
INSTALLATION  
Door Glass ..................................................................25  
Replacement ...............................................................25  
Glass Gasket...............................................................25  
Fan Maintenance.........................................................26  
Valve assembly replacement.......................................27  
Important Message........................................................5  
For Your Safety..............................................................5  
Before You Start ............................................................5  
Installation Checklist......................................................5  
Materials Required ........................................................5  
Minimum Fireplace Dimensions ....................................6  
Clearances To Combustibles.........................................6  
Gas Connection ............................................................6  
Flueing...........................................................................6  
Flue Liner Installation ....................................................7  
Gas Pipe Pressure Testing............................................7  
Installation in masonry or zero clearance chimney........8  
Aeration Settings...........................................................9  
Conversion Kit #486-968 for NG to LPG Model ..........10  
Conversion Kit #486-967 for NG to ULPG...................12  
Optional Stainless steel inner panel install..................14  
Log set installation.......................................................15  
Glass Door installation.................................................18  
Standard Flush Door ...................................................18  
Optional Flush Trim .........................................................  
Faceplate & Optional plinth trim Assembly..................19  
Faceplate and door frame Installation.........................20  
Thermodisc installation................................................21  
Final Check..................................................................22  
Wiring standard ...........................................................22  
Operating Instructions ................................................23  
Lighting Instructions.....................................................23  
Shutdown Instructions.................................................23  
First Fire ......................................................................23  
Remote Control ..........................................................23  
Summary of Controls ..................................................23  
Fan Operation..............................................................23  
Copy Of Lighting Instruction Plate...............................24  
Normal Operating Sounds Of Gas Appliances............24  
Resetting the unit.........................................................24  
PARTS LIST  
Electronic Components Parts List ...............................28  
Main Assembly ............................................................29  
Faceplate Assembly ....................................................30  
WARRANTY  
Warranty......................................................................31  
Regency IG34 Gas Inbuilt Fireplace  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
DATA BADGE  
This is a copy of the label that accompanies each Regency IG34 Gas  
Inbuilt replace. We have printed a copy of the contents here for your  
review.  
Check the label on the unit and if there is a difference, the label on the  
unit is the correct one.  
DATA BADGE NOTE: Regency units are constantly being improved.  
Regency Gas Fireplace  
Distributed by:  
Model  
Western Australia:  
Gas Type  
NG  
LPG  
IG34-LPG  
30.6mj.  
ULPG  
IG34-ULPG  
26.4mj.  
Air Group Australia  
28 Division St  
Welshpool WA 6106  
Model  
IG34-NG  
31.7mj.  
0.87 kPa  
1x#37  
Eastern Australia:  
Gas Consumption  
Manifold Pressure  
Injector Size  
Fireplace Products  
Australia Pty. Ltd.  
21-23 South Link Blvd.  
Dandenong, VIC 3175  
2.51 kPa  
1x#52  
2.51 kPa  
1x#53  
To be installed by an authorised person in  
accordance with installation instructions provided  
with the appliance.  
2.64mm  
1.61mm  
1.51mm  
AGA Approval 7469  
Code AS4553 NZS 5262  
Serial  
Number  
347  
Electrical: 240VAC 50Hz 1.0 amp  
N2134  
918-794  
(Australia Only)  
4
Regency IG34 Gas Inbuilt Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
IMPORTANT MESSAGE  
BEFORE YOU START  
INSTALLATION  
CHECKLIST  
The Regency Gas Inbuilt must be installed in Installation is to be carried out ONLY by an  
accordance with these instructions. Carefully authorised person.  
read all the instructions in this manual rst.  
Before installing vent system ensure that the  
damper plate is open and secure to prevent the  
damper plate from falling down and crushing  
the liner.  
1) The appliance shall be installed in accord-  
Note: Failure to follow these instructions  
could cause a malfunction of the  
heater which could result in death,  
serious bodily injury, and/or prop-  
erty damage. Failure to follow these  
instructions may also void your re  
insurance and/or warranty.  
ance with the manufacturer's installation  
instructions, local gas tting regulations,  
municipal building codes, water supply  
regulations, electrical wiring regulations,  
with AS5601. (AGA gas installation code)  
NZS 5262(New Zealand)  
The FPI Gas Inbuilt is installed as listed.  
1) Checkallclearancestocombustibles,(Refer  
tosections"MinimumFireplaceDimensions  
and Clearances to Combustibles)  
2) Installation and repair should be done  
ONLY by an authorised person.  
2) Make the gas connection. (Refer to section  
"Gas Connection")  
3) The appliance should be inspected before  
use and at least annually by an authorised  
serviceperson.Morefrequentcleaningmay  
berequiredduetoexcessivelintfromcarpet-  
ing, bedding material, etc. It is imperative  
that control compartments, burners and  
circulatingairpassagewaysoftheappliance  
be kept clean and free from excessive lint  
from carpeting.  
3) Installthe3"(76.2mm)uelinertothesliding  
connectorplate.(Refertosection"FlueLiner  
Installation.")  
FOR YOUR SAFETY  
This appliance requires air for proper combus-  
tion. Always provide adequate combustion  
and ventilation air. Follow instructions and  
information in the current AS5601, NZS 5262  
or local codes. Consult the "authority having  
jurisdiction" to determine the need for a permit  
prior to starting the installation.  
4) Slide the unit half way into the replace.  
5) Pull the vent connector plate through the  
taperedbracketsandfastentothefrontplate.  
Refer to section "Flue Liner Installation.")  
4) See general construction and assembly  
instructions. This appliance may only be in-  
stalledinaued,non-combustiblereplace.  
The appliance and ue should be enclosed  
when installed or passing through a living  
area, where children may come in contact  
with it.  
6) Slide the unit fully into the replace.  
7) Test gas pressure (Refer to section "Gas  
Pipe Pressure Testing"). Check aeration  
system(Refertosection"GasInsertAeration  
System").  
MATERIALS REQUIRED  
A 240 Volt AC power cord is hooked up to the  
unit. Plug 3 wire cord into a suitable receptacle.  
Do not cut the ground terminal off under any  
circumstances.  
8) Installstandardandoptionalfeatures. Refer  
5) Alwaysconnectthisspaceheatertoachim-  
ney and ue to the outside of the building  
envelope.Neveruetoanotherroom. Make  
sure that the ue is properly sized and is  
of adequate height to provide the proper  
draft.  
to the following sections:  
a. Log Set  
b. Faceplate & Door Trim  
c. Inner Stainless Panels  
When connected with 240 volts, the appliance  
must be electrically grounded in accordance  
with local codes.  
9) Finalcheck:Beforeleavingthisunitwiththe  
customer, the installer must ensure that the  
appliance is ring correctly. This includes:  
6) Inspect the ueing system annually for  
This unit is polarity sensitive and will not  
operate if polarity is incorrect.  
blockage and any signs of deterioration.  
7) Any safety glass removed for servicing  
must be replaced prior to operating the ap-  
pliance.  
a) Clocking the appliance to ensure the  
correct ring rate.  
b) Adjusting the primary air and restrictor  
settings, if required, to ensure that the  
ame does not carbon.  
8) To prevent injury, do not allow anyone who  
is unfamiliar with the operation to use the  
replace.  
WARNING:  
Suitable for installation into a masonry  
replace only.  
9) Installer must mechanically attach the sup-  
plied label to the inside of the rebox of the  
replace into which the gas replace insert  
is installed.  
NOTE:  
TO BE INSTALLED ON A  
NON- COMBUSTIBLE FLOOR.  
"WARNING:Thisreplacehasbeenconverted  
for use with a gas replace insert only and  
cannot be used for burning wood or solid fuels  
unless all original parts have been replaced,  
and the replace re-approved by the authority  
having jurisdiction."  
Regency IG34 Gas Inbuilt Fireplace  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
Mantel Clearances  
MINIMUM FIREPLACE  
DIMENSIONS  
FLUEING  
THE APPLIANCE MUST NOT  
BE CONNECTED TO A  
The minimum replace dimensions for the  
Regency gas space heater are shown in the  
following diagrams:  
CHIMNEY FLUE SERVING A  
SEPARATE SOLID FUEL  
BURNING APPLIANCE AND  
MUST BE TERMINATED TO  
THE OUTDOORS.  
This appliance is designed to be attached to  
two 3" (76mm) co-linear aluminium ex running  
the full length of the chimney. The ue length  
must be a minimum length of 8 ' (2.44m) and  
a maximum of 35' (10.7m). See chart below for  
minimumdistancesfromroof.Periodicallycheck  
that the vent is unrestricted.  
Masonry chimneys may take various contours  
which the exible liner will accommodate.  
However,keeptheexiblelinerasstraightas  
possible, avoid unnecessary bending.  
Note: A non-combustible mantel may be  
installedatalowerheightifthefram-  
ing is made of metal studs covered  
with a non-combustible board.  
TheAir Intake pipe must be attached to the inlet  
air collar of the termination cap.  
Part #  
Description  
948-305  
46dva-gk  
76mm Flex - 10.6m  
Simpson Duravent Adaptor  
GAS CONNECTION  
46dva-vch Simpson Vertical high wind cap  
CLEARANCES TO  
COMBUSTIBLES  
GAS CONNECTION WARNING:  
Only persons licensed to work  
with gas piping may make the  
necessary gas connections  
to this appliance.  
Minimum Clearances to Combustibles  
From Unit  
Sides  
Ceiling  
Mantel  
A
B
C
10" / 255mm  
47.5" / 1205mm  
13" / 330mm  
1) If the appliance is to be installed into an  
existing chimney system, thoroughly clean  
the masonry replace.  
Max. Mantle Depth  
E
12" / 305mm  
(see Dia. 2)  
2) The appliance is provided with an opening  
on the right hand side of the control  
compartment. The 9.5mm (3/8") exible  
gas hose provided needs to be brought in  
from behind this opening. Ensure all gas  
connections are tight.  
Min. Alcove Width  
Max. Alcove Depth  
F
G
48" / 1220 mm  
36" / 915 mm  
*No hearth required.  
3) Locate the center point where the vent  
will pass through the chimney above the  
appliance. Move the appliance into the  
exact location where it is to be installed.  
Ensure that the Insert is level.  
C
L
Note: When installing the flueing, identify  
the flues.  
Mark one exhaust and one intake as  
indicated on the top of the unit.  
Gas  
Inlet  
6
Regency IG34 Gas Inbuilt Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
The Air Intake pipe must be attached to the  
inlet air collar of the termination cap.  
4) Seal and or check the pilot outlet (# 8)  
5) The pressure check should be carried out  
withtheunitburningandthesettingshould  
be within the limits specied on the safety  
label.  
6) When nished reading manometer, turn  
off the gas valve, disconnect the hose and  
tighten the screw (clockwise) with a 1/8"  
at screwdriver. Screw should be snug,  
but do not over tighten.  
FLUE LINER  
INSTALLATION  
S.I.T. Valve Description  
Be careful not to damage thermal insula-  
tion when sliding on vent connector plate.  
This could cause blockage.  
1) On-Off Solenoid Valve EV1  
2) On-Off Solenoid Valve EV2  
3) Inlet Pressure Test Point  
4) Outlet Pressure Test Point  
5) Connection for Pressure Regulator/  
Combustion Chamber Compensation  
6) Pressure Regulator for Minimum and  
Maximum Outlet Pressure  
1) Cut the ex liner as required.  
2) Mark the end of one liner to indicate  
Inlet.  
9) Connect the 2nd liner to the exhaust collar  
marked with an "E", seal connection with  
high temperature silicone. Secure with gear  
clamp.  
3) Connect the other end of the above liner to  
theinletsideoftheterminationadaptor,seal  
connection with high temperature silicone.  
Secure with gear clamp.  
7) Gas Outlet Pressure Electric Modulator  
8) Pilot Outlet  
4) Connect the 2nd liner to the exhaust side  
of the adaptor, seal connection with high  
temperature silicone. Secure with gear  
clamp.  
9) Main Gas Outlet  
10) Side Outlet  
GAS PIPE PRESSURE  
TESTING  
The appliance must be isolated from the gas  
supply piping system by closing its individual  
manual shut-off valve during any pressure  
testing of the gas supply piping system at  
test pressures equal to or less than 1/2 psig.  
(3.45 kPa). Disconnect piping from valve at  
pressures over 3.45 kPa (14" w.c.).  
The manifold pressure is controlled by a  
regulator built into the gas control, and should  
be checked at the pressure test point.  
5) Install ashing.  
Note: To properly check gas pressure,  
both inlet and manifold pressures  
shouldbecheckedusingthevalve  
pressure ports on the valve.  
6) Insert both liners into chimney, passing  
through the damper opening.  
7) Install termination cap.  
1) Make sure the valve is in the "OFF"  
position.  
8) Connectthemarkedendofthelinertotheinlet  
collaroftheventconnectorplatemarkedwith  
an "I", seal connection with high temperature  
silicone. Secure with gear clamp.  
2) Loosen the "IN" (# 3) and/or "OUT" (# 4)  
pressure tap(s), turning counterclockwise  
with a 1/8" wide at screwdriver.  
Install to AS5601 (Australia) /  
NZS 5262 (New Zealand)  
3) Attach manometer to "IN" and/or "OUT"  
pressure tap(s) using a 5/16" (8mm) ID  
hose.  
Regency IG34 Gas Inbuilt Fireplace  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
INSTALLATION IN MASONRY OR ZERO CLEARANCE CHIMNEY  
1) Measure and record dimensions to determine total  
Flex Liner length requirements (see instructions below  
for details).  
Note: If you are planning to extend the height of the  
chimney using Direct Vent GS Pipe, please refer to the  
Direct Vent Installation Instructions for information con-  
cerning the proper procedure and restrictions of Direct  
Vent Pipe.  
2) Carefully feed the liner down the chimney (masonry  
or zero clearance) and out through the damper. One  
person should feed the liner through the chimney, and  
another person should pull the liner from the bottom.  
Also, consult the appliance manufacturer for any height  
restrictions of the chimney.  
9) Connect the Co-Linear Flex to the two outlets on the  
top of the appliance using four sheet metal screws each.  
See the appliance manufacturer's instructions for de-  
tails. Make sure the Flex Liners do not sag behind the  
appliance. Finally, move the appliance into its appropri-  
ate place. Mount the Adaptor to the Baseplate using  
sheet metal screws.  
3) After carefully feeding the Flex Liner down the chim-  
ney to the bottom, form and angle to line up the Flex  
Liner with the vent opening on the appliance.  
Important: Do not let the Flex Liner sag below the level  
at which it will connect to the appliance or connector.  
This could allow hot gas to become trapped and poten-  
tially become a re hazard. The Flex Liner path should  
always be sloped up toward the Termination Cap.  
4) Temporarily secure the Flex Liner at the top of the  
chimney. Be sure to leave 2-3 inches of ex above the  
existing chimney to allow for connection to the Termina-  
tion Kit (Baseplate and Adaptor).  
Flex  
Liners  
Existing  
Chimney  
5) Repeat Steps 1-4 for second length of Flex Liner.  
6) At the top of the chimney, slide the Baseplate over  
the tow ends of the Flex Liner and secure it to the sur-  
rounding masonry using masonry anchor bolts. Before  
installing the baseplate, run a bead of non-hardening  
seal and between the Baseplate and the masonry to  
prevent moisture from entering the chimney.  
Note: Verify that there is sufcient room to mount the  
Baseplate on to the masonry. You must have a level  
surface in order to install the Baseplate properly.  
7) Attach the Flex Liner ends at the top of the chimney  
to the Co-Linear to Co-Axial Adaptor. Use four sheet  
metal screws to connect each Flex Liner run to the  
Adaptor.  
8) Twist lock the Vertical Termination Cap to the Adap-  
tor.  
8
Regency IG34 Gas Inbuilt Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
System Data  
IG34  
IG34-NG: For 0 to 610 meters altitude  
IG34-LPG: For 0 to 610 meters altitude  
IG34-ULPG: For 0 to 610 meters altitude  
Burner Inlet Orice Sizes:  
NG  
#37  
LPG  
#52  
ULPG  
#53  
Burner  
Max. Input  
NG  
31.7 mj  
LPG  
ULPG  
30.6 mj  
26.4 mj  
Min. Input  
NG  
21.1 mj  
25.1 mj  
20.9 mj  
LPG  
ULPG  
Supply Pressure  
NG  
LPG  
ULPG  
1.13 kPa  
2.75 kPa  
2.75 kPa  
Manifold Pressure HIGH  
LOW  
0.4kPa  
1.6kPa  
1.6kPa  
NG  
0.87 kPa  
2.51 kPa  
2.51 kPa  
LPG  
ULPG  
Electrical: 240 V. 50Hz.  
Circulation: High/Off/LO speed fan,  
150/89 CFM.  
Log Set: Ceramic ber, 7 per set.  
Aeration Setting  
NG  
LPG  
13mm open  
13mm open  
ULPG 13mm open  
AERATION SETTINGS  
The burner aeration is factory set but may need adjusting due to either the local gas supply, air supply or altitude. This adjustment is performed by  
the installer. (Close the aeration for a more yellow ame, or open it to make the ame bluer).  
NG:  
LPG:  
ULPG:  
13mm open  
13mm open  
13mm open  
Note: Any damage due to carboning resulting from improperly setting the aeration and restrictor setting controls is NOT covered  
under warranty.  
Regency IG34 Gas Inbuilt Fireplace  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
Conversion Kit #486-968 for NG to LPG Model  
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER  
IF IN DOUBT DO NOT DO THIS CONVERSION !!  
12) Replace the yellow "NG" label with  
Conversion Kit 486-968 Contains:  
the red "ULPG" label.  
9) Pull out the pilot hood by hand.  
Qty. Part # Description  
13) Carefully pull out the control box.  
1 904-345 Burner Orifice #51  
1 918-273 Red "LPG" label  
1 918-272 Label "Converted to LPG"  
1 910-037 LPG Pilot Injector  
1 918-823 Instruction Sheet  
Pilot  
Hood  
NOTE: The control box is held in  
place with velcro.  
14) Remove the heat shield from the  
control box by removing the 2  
screws.  
1) Shut off the gas supply and unplug  
the power cord.  
15) Remove the control box cover by  
undoing the 3 screws.  
2) Remove the glass door, logs and  
lava rock.  
Manoeuvre through antenna.  
Pilot  
Hood  
removed  
3) Remove the rear log tray by remov-  
ing the 2 screws. (Log tray must be  
rotated to clear the burner.)  
Pilot  
Orifice  
4) Remove the grate.  
Antenna  
5) Remove the burner and ensure the  
aeration setting is 13 mm open.  
Control Box  
Cover  
10) Remove the pilot orifice with the  
6) Remove burner orifice with a 1/2"  
wrench and discard. Use a wrench  
to hold on to the elbow behind the  
orifice.  
allen key.  
16) Remove the jumper using a plier.  
11) Put in the new LPG orifice with the  
allen key. Then put back the pilot  
hood.  
Jumper Location  
Burner  
7) Reinstall new burner orifice LPG  
stamped #51 and tighten.  
8) Apply the conversion label "This  
unit has been converted to ULPG"  
over top of the serial number decal.  
Jumper  
Note: Aeration settings do not need  
to be adjusted.  
17) Reverse steps 13, 12, 11, 6, 5, 4, 3  
& 2.  
10  
Regency IG34 Gas Inbuilt Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
18) Turn on gas supply and plug in power cord.  
After carrying out all adjustments, block the setting screws  
with paint, taking care not to obstruct the breather orifice  
of the pressure.  
19) Adjusting the Outlet Pressure  
Put back the modulator plastic cap.  
All the adjustments must be  
carried out in the following order:  
WARNING: To ensure the correct operation of the modu-  
lator it is necessary that the plastic cap (A) is returned to  
its original location.  
Remove the modulator plastic cap (A) using needle nose  
pliers.  
Maximum pressure: Turn the unit ON to its highest input  
rating. Screw in the nut (B) to increase the outlet pressure  
and screw it out to decrease it. Use a 10 mm wrench.  
NOTE: The outlet pressure must be set to maximum 2.51  
kPa.  
A
C
B
Minimum pressure: Remove one of the cables connect-  
ed to the electric modulator. While holding the nut (B) with  
a wrench, screw in the screw (C) to increase the pressure  
and screw it out to decrease it. Use a screwdriver 6 x 1  
blade.  
NOTE: The outlet pressure must be set to minimum 1.6  
kPa.  
20) Turn on gas supply and plug in power cord.  
21) At the end of all setting and adjustment operations, check  
electrical installation and gas leaks.  
Cable  
22) Check operation of flame control.  
Electric  
Modulator  
23) Check for proper flame appearance and glow on logs.  
Installer Notice:  
These instructions must be left  
with the appliance.  
Regency IG34 Gas Inbuilt Fireplace  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
Conversion Kit #486-967 for NG to ULPG  
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER  
IF IN DOUBT DO NOT DO THIS CONVERSION !!  
12) Replace the yellow "NG" label with  
Conversion Kit 486-967 Contains:  
the red "ULPG" label.  
9) Pull out the pilot hood by hand.  
Qty. Part # Description  
13) Carefully pull out the control box.  
1 904-345 Burner Orifice #53  
1 918-273 Red "ULPG" label  
1 918-272 Label "Converted to ULPG"  
1 910-037 LPG Pilot Injector  
1 918-824 Instruction Sheet  
Pilot  
Hood  
NOTE: The control box is held in  
place with velcro.  
14) Remove the heat shield from the  
control box by removing the 2  
screws.  
1) Shut off the gas supply and unplug  
the power cord.  
15) Remove the control box cover by  
undoing the 3 screws.  
2) Remove the glass door, logs and  
lava rock.  
Maneuver through antenna.  
Pilot  
Hood  
removed  
3) Remove the rear log tray by remov-  
ing the 2 screws. (Log tray must be  
rotated to clear the burner.)  
Pilot  
Orifice  
4) Remove the grate.  
Antenna  
5) Remove the burner and ensure the  
aeration setting is 13 mm open.  
Control Box  
Cover  
10) Remove the pilot orifice with the  
6) Remove burner orifice with a 1/2"  
wrench and discard. Use a wrench  
to hold on to the elbow behind the  
orifice.  
allen key.  
16) Remove the jumper using a plier.  
11) Put in the new LPG orifice with the  
allen key. Then put back the pilot  
hood.  
Burner  
Jumper Location  
7) Reinstall new burner orifice ULPG  
stamped #53 and tighten.  
8) Apply the conversion label "This  
unit has been converted to ULPG"  
over top of the serial number decal.  
Jumper  
Note: Aeration settings do not need  
to be adjusted.  
17) Reverse steps 13, 12, 11, 6, 5, 4, 3  
& 2.  
12  
Regency IG34 Gas Inbuilt Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
18) Turn on gas supply and plug in power cord.  
After carrying out all adjustments, block the setting screws  
with paint, taking care not to obstruct the breather orifice  
of the pressure.  
19) Adjusting the Outlet Pressure  
All the adjustments must be  
carried out in the following order:  
Put back the modulator plastic cap.  
WARNING: To ensure the correct operation of the modu-  
lator it is necessary that the plastic cap (A) is returned to  
its original location.  
Remove the modulator plastic cap (A) using needle nose  
pliers.  
Maximum pressure: Turn the unit ON to its highest input  
rating. Screw in the nut (B) to increase the outlet pressure  
and screw it out to decrease it. Use a 10 mm wrench.  
NOTE: The outlet pressure must be set to maximum 2.51  
kPa.  
A
C
B
Minimum pressure: Remove one of the cables connect-  
ed to the electric modulator. While holding the nut (B) with  
a wrench, screw in the screw (C) to increase the pressure  
and screw it out to decrease it. Use a screwdriver 6 x 1  
blade.  
NOTE: The outlet pressure must be set to minimum 1.6  
20) Turn on gas supply and plug in power cord.  
kPa.  
21) At the end of all setting and adjustment operations, check  
electrical installation and gas leaks.  
Cable  
22) Check operation of flame control.  
Electric  
23) Check for proper flame appearance and glow on logs.  
Modulator  
Installer Notice:  
These instructions must be left  
with the appliance.  
Regency IG34 Gas Inbuilt Fireplace  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
OPTIONAL STAINLESS STEEL INNER PANEL INSTALL  
Before you start:  
Stainless panels must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time. Claims for  
damage after installation will not receive consideration.  
To protect the finish during installation and handling - cotton gloves MUST be worn at all times while handling the panels (even  
when removing protective coating).  
Stainless panels will discolor a little during normal operation. This is normal and should not be considered a defect.  
All hand and finger marks MUST be cleaned off with a soft cloth and a stainless steel cleaner. Most stainless steel cleaners leave a  
film/residue on the surface of the panels. Use an ammonia based cleaner (ie. glass cleaner) to remove this film before applying heat to  
the unit. Failure to do this will result in burn stains on panels which you will be unable to remove. This is not a warranty item.  
1) Remove faceplate, inner door frame and screen if  
6) Remove the two side brackets and screws (set aside) - then  
already installed. Refer to page 18 in the instruction manual.  
remove the side panels by tilting the top in and lifting them out.  
2) Remove the glass door by undoing 2 latches - lift up and out.  
Refer to page 17 in the manual for detailed instructions.  
7) Orient the stainless side panels with the larger fold in the  
panel facing in towards the burner and facing the back of the  
firebox.  
3) Remove all the logs if installed and set aside carefully.  
4) Loosen the 4 screws securing the brackets that hold the existing  
back and side panels in place.  
Larger fold in the  
metal.  
5) Remove the two back brackets and screws (set aside) first, then  
remove the back panel by lifting it up slightly, tilt it forward,  
then lift it out.  
8) Secure the stainless panel with original bracket and screw - repeat  
procedure on the opposite side.  
9) Reinstall the (original black) back panel - secure with 2 brackets  
and 2 screws (ones that were removed initially).  
10) Reinstall the logs, glass door, inner door frame with screen  
and finally the faceplate. See manual for detailed instructions.  
Final installation of optional stainless panels.  
14  
Regency IG34 Gas Inbuilt Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
LOG SET INSTALLATION  
Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until  
they are replaced. Broken logs can interfere with the pilot operation.  
The gas log kit contains the following:  
a) 02-43  
b) 02-45  
c) 02-56  
d) 02-46  
e) 02-47  
f) 02-48  
g) 02-44  
h) 902-154  
i) 902-153  
Rear Log  
Front Right Log  
Middle Left Log  
Left Top Log  
Center Log  
Middle Right Log  
Front Left Log  
Embers  
Vermiculite  
and embers  
Vermiculite  
and embers  
Vermiculite  
and embers  
Rockwool  
j) 902-179/P Vermiculite  
k) 946-669  
Platinum Embers  
(supplied with packaged manual)  
3) Place Rear Log A)02-43 on the two pins on the rear  
log support.  
A)02-43  
Pins on Rear Log Support  
The "02" refer numbers (i.e. 02-43) are  
molded into the rear of each log.  
4) Place Front Right Log B)02-45 on the two pins as  
shown.  
Note: Install Optional Brick Panels prior to installing logs.  
1) Carefully remove the logs from the box and unwrap  
them. The logs are fragile, handle with care - do not  
force into position.  
2) Sprinkle the vermiculite around the firebox base. Take  
some of the embers (approx. 1/3 of the bag) and  
sprinkle over the vermiculite.  
B)02-45  
Regency IG34 Gas Inbuilt Fireplace  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
5) Place the Middle Left Log C)02-56 on the two pins as  
7) Place the notch in Center Log E)02-47 over Log B)02-  
shown.  
45 and across the cutout on Log A)02-43.  
E)02-47  
A)02-43  
B)02-45  
C)02-56  
Notch  
Cutout  
Logs A)02-43, C)02-56, and B)02-45 in position  
Logs D)02-46 and E)02-47 in position.  
6) Place the Left Top Log D)02-46 on the pin on Log  
8) Position notch in Front Right Log F)02-48 on Log  
E)02-47 and push the bottom right edge against the  
bracket on the burner tray and the front edge of the  
rear burner.  
C)02-56 and on top of the cutout on Log A)02-43.  
Notch  
D)02-46  
F)02-48  
A)02-43  
C)02-56  
Bracket  
B)02-45  
Pin  
Cutout  
16  
Regency IG34 Gas Inbuilt Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
Front edge of  
rear burner  
10) Place the embers and Rockwool on the exposed front  
burner tray.  
A)02-43  
F)02-48  
Side View  
Bracket  
The bottom right edge of Log F)02-48 must sit snugly against  
the bracket and the front edge of the rear burner.  
11) Separate platinum embers and place on and around  
the embers and rockwool on the burner tray. Avoid  
stacking platinum embers.  
9) Place Front Left Log G)02-44 onto the 2 front pins as  
12) Test fire to ensure proper light off (make sure flame  
flows smoothly from one end of burner to the other. If  
there is any flame hesitation, check that area for any  
blockage of the burner port.  
shown.  
G) 02-48  
A) 02-43  
D) 02-46  
G)02-44  
F) 02-47  
E) 02-45  
B) 02-56  
C) 02-44  
The "02" refer numbers (i.e. 02-43) are  
molded into the rear of each log.  
Regency IG34 Gas Inbuilt Fireplace  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
GLASS DOOR INSTALLATION  
STANDARD FLUSH DOOR  
The standard ush door comes with a black frame. To install the frame  
and glass door, simply hook the top door ange onto the top of the unit  
and swing the door towards the unit, diagram 1. Be careful that the glass  
gasket does not roll up; there must be a gap between the gasket and the  
door lip to ensure that the door sits securely on the unit. See Diagram 2.  
Diagram 1  
Diagram 2  
Use the hook to pull the spring out until you can put the hook  
into the slot on the bottom door bracket. Repeat for 2nd spring.  
See diagram 3.  
To remove the ush door, reverse the above steps.  
Diagram 3  
To remove the ush door, reverse the above steps.  
18  
Regency IG34 Gas Inbuilt Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
FACEPLATE & OPTIONAL PLINTH TRIM ASSEMBLY  
1) Lay the faceplate panels flat, face down on something soft so they don't scratch.  
2) Take the top faceplate and align the holes in it with the holes in the side panels.  
Secure with provided nuts and bolts.  
IG34 Faceplate Assembly / Plinth  
1
1
1
1
6
1
336-914  
366-942  
336-016  
336-072F  
904-576  
336-012  
Faceplate / Trim Kit  
Plinth Kit (optional)  
Mesh Screen Door  
Mesh Bottom Screen  
#8 Phillips pan head screws  
Bottom Door  
Plinth Trim Option:  
Plinth Trim Kits are an option that can be used to finish off the installation when the bottom of the fireplace is higher than the  
hearth or to raise the fireplace.  
1) Lay the faceplate side panels flat, face down on something soft so they don't scratch.  
2) Attach the Plinth Trim to the bottom of the faceplate side panels with the screws provided.  
3) Install faceplate on unit - see next page.  
SCREEN INSTALLATION  
1) Hook the screen over the top of the door frame - lower until  
2) Flip door frame and screen over - locate the bracket tab at  
screen is flush with the door frame.  
the bottom of the door frame - fold the tab over 90º to secure  
the screen in place.  
3) Install screen and door frame on to unit - follow directions  
on next page.  
Regency IG34 Gas Inbuilt Fireplace  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
FACEPLATE AND DOOR FRAME INSTALLATION  
4) Push both bottom frame hinges down on the metal lip until  
1) Position faceplate on unit lining up screw holes on  
they are fully seated.  
faceplate with screw holes on unit - secure with 4 screws.  
5) Flip bottom louver up to close.  
2) Install lower screw below glass door - secure with 4 screws.  
6) Install the door frame by hooking the top flange over the  
top of the glass door.  
Note: Ensure that the flanges on the sides of the firebox  
are on the outside, when installing the faceplate  
(see below).  
Faceplate  
Flange on firebox  
3) Fold down the 2 hinges on the bottom frame to a flat  
position.  
The bottom frame is installed with a friction fit - the  
opening in the corner of each hinge slides over the  
metal lip located on the floor of the unit.  
Note: Ensure the bottom frame is positioned properly  
before installing, by making sure there is equal spacing on  
either side.  
Door Frame  
Glass Door  
7) Lower the door frame gently into place.  
8) To uninstall - reverse procedure.  
Openings on hinge  
Metal Lip  
Completed Faceplate & Door Frame Installation  
with Safety Screen  
20  
Regency IG34 Gas Inbuilt Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
THERMODISC INSTALLATION  
1) Install faceplate and door frame as per previous page.  
5) Secure wiring along the vertical right side of the faceplate  
(facing the back of the faceplate) with supplied grey adhesive clips.  
2) After faceplate has been installed - place the touch pad (facing  
out) in the knockout located on the left side of the faceplate.  
3) Secure with 2 screws as shown below.  
Back of Faceplate  
6) Slide unit into nal position.  
4) Take the limit switch harness and slide the thermodisc into the  
bracket located on the top backside of the faceplate. Secure with  
2 screws as shown below.  
Thermodisc  
Bracket  
Back of Faceplate  
Regency IG34 Gas Inbuilt Fireplace  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
FINAL CHECK  
Before leaving this unit with the customer, the installer must ensure that the appliance is ring correctly. This includes:  
1) Clocking the appliance to ensure the correct ring rate (rate noted on label) at 15 minutes.  
2) If required, adjusting the primary air to ensure that the ame does not carbon. First allow the unit to burn for 15 min. to stabilize.  
3) Check for proper draft.  
CAUTION  
Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the  
responsibility of the manufacturer.  
WIRING  
This unit is polarity sensitive and will  
not operate if polarity is incorrect.  
CAUTION: Labelallwirespriortodisconnection  
when servicing controls. Wiring errors can  
cause improper and dangerous operation.  
Caution: Ensure that the wires do not  
touch any hot surfaces and are away  
from sharp edges.  
STANDARD WIRING  
22  
Regency IG34 Gas Inbuilt Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
OPERATING  
INSTRUCTIONS  
SUMMARY OF  
CONTROLS  
FIRST FIRE  
The FIRST FIRE in your heater is part of the  
paint curing process. To ensure that the paint  
is properly cured, it is recommended that you  
burn your replace for at least four (4) hours the  
rst time you use it with the fan on.  
Beforeoperatingthisappliance,proceedthrough  
the following check list.  
On/Off Button  
Iftheunit isswitchedoff,pressingandreleasing  
this button once will switch the unit on. The unit  
will resume its last settings.  
1) Read and understand these Instructions  
before operating this appliance.  
When rst operated, the unit will release an  
odour caused by the curing of the paint and the  
burning off of any oils remaining from manufac-  
turing. Smoke detectors in the house may go off  
at this time. Open a few windows to ventilate  
the room for a couple of hours. The glass may  
require cleaning.  
Iftheunitisswitchedon, pressingandreleasing  
this button once will switch the unit off.  
2) Check to see that all wiring is correct and  
enclosed to prevent possible shock.  
Flame:  
Increase - If the unit is switched on, pressing  
and releasing the ame plus (+) button once will  
increase the ame height to the next available  
high setting.  
3) Check to ensure there are no gas leaks.  
4) Make sure the glass door is in place. Never  
operate the appliance with the door glass  
removed.  
NOTE: The main burner will always start on  
"HIGH" and resume it's last setting after  
20 seconds of operation.  
Decrease - If the unit is switched on, pressing  
and releasing the ame minus (-) button once  
will decrease the ame height to the next avail-  
able low setting.  
5) Verify that all ueing and the cap is unob-  
structed.  
NOTE: Whentheglassiscoldandtheappliance  
is lit, it may cause condensation and fog  
the glass. This condensation is normal  
and will disappear in a few minutes as  
the glass heats up.  
6) Verify log placement.  
Fan:  
Increase - If the unit is switched on, pressing  
and releasing the fan plus (+) button once will  
increase the fan speed to the next available  
high setting.  
7) The unit should never be turned off and on  
again without a minimum of a 60 second  
wait.  
DO NOT ATTEMPT TO CLEAN THE  
8) When lighting the appliance, the inside of  
the glass may fog up. This will burn off after  
a few minutes of operation.  
GLASS WHILE IT IS STILL HOT!  
Decrease - If the unit is switched on, pressing  
and releasing the fan minus (-) button once will  
decrease the fan speed to the next available  
low setting.  
DO NOT BURN THE APPLIANCE WITH-  
OUT THE GLASS FRONT IN PLACE.  
LIGHTING  
INSTRUCTIONS  
FAN OPERATION  
REMOTE CONTROL  
Set the fan speed on the control panel at the top  
rear of the unit to adjust to the desired speed.  
Use the Regency Remote Control Kit approved  
for this unit. Use of other systems may void  
your warranty.  
1) Plug the power cord into a power outlet.  
Pressing and releasing the plus (+) FAN button  
will change the fan speed as follows:  
2) Press and release the ON/OFF switch once  
to start the unit. The LED will be lit.  
The remote control kit comes with a hand held  
transmitter and a wall mounting plate.  
OFF -> LOW -> MEDIUM -> HIGH -> OFF,  
etc.  
3) After approximately 8 seconds the spark  
ignition system will spark for 8 seconds to  
light the main burner.  
1) Choose a convenient location to mount  
the hand held transmitter, protection from  
extreme heat is very important.  
Pressingandreleasingtheminus(-)FANbutton  
will be the reverse of the above.  
4) Ifthemainburnerdoesnotlight, repeatstep  
2 to restart the unit.  
By using the wall mounting plate to house the  
transmitter, the remote can also be used as a  
wall thermostat.  
Fan must be running at all times  
when the unit is in operation.  
SHUTDOWN  
INSTRUCTIONS  
1) Press the ON/OFF switch once.  
ADJUSTING FLAME  
HEIGHT  
2) The LED will ash.  
Therearesixamesettingsthatcanbeadjusted  
bypressingandreleasingtheplus(+)and minus  
(-) FLAME button.  
3) Turn off all electric power to the appliance  
if service is to be performed.  
Regency IG34 Gas Inbuilt Fireplace  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
NORMAL OPERATING  
SOUNDS OF  
COPY OF LIGHTING INSTRUCTION PLATE  
GAS APPLIANCES  
FOR YOUR SAFETY READ BEFORE LIGHTING  
This appliance must be installed in accordance with local codes, if any; if not,  
follow the current CAN1-B149/ANSI Z 223.1 (Australia: AS5601-2004, New Zealand: NZS 5261)  
It is possible that you will hear some sounds  
fromyourgasappliance.Thisisperfectlynormal  
due to the fact that there are various gauges  
and types of steel used within your appliance.  
Listedbelowaresomeexamples.Allarenormal  
operatingsoundsandshouldnotbeconsidered  
as defects in your appliance.  
WARNING: If you do not follow these instructions exactly, a fire or explosion may result  
causing property damage, personal injury or loss of life. Improper installation, adjustment,  
alteration, service or maintenance can cause injury or property damage. Refer to the  
owner’s information manual provided with this appliance. For assistance or additional  
information consult a qualified installer, service agency or gas supplier.  
A) BEFORE LIGHTING smell all around the appliance area  
for gas. Be sure to smell next to the floor because some  
gas is heavier than air and will settle on the floor.  
B) Donotusethisapplianceifanyparthasbeenunderwater.  
Immediately call a qualified service technician to inspect  
theapplianceandtoreplaceanypartofthecontrolsystem  
and any gas control which has been under water.  
Blower:  
Regency gas appliances use high tech blowers  
to push heated air farther into the room. It is not  
unusual for the fan to make a "whirring" sound  
when ON. This sound will increase or decrease  
in volume depending on the speed setting of  
your fan speed control.  
WHAT TO DO IF YOU SMELL GAS  
- Do not try to light any appliance  
This appliance needs fresh air for safe operation and  
must be installed so there are provisions for adequate  
combustion and ventilation air.  
- Do not touch any electric switch, do not use any  
phone in your building  
- Immediately call your gas supplier from a neighbors  
phone. Follow the gas supplier’s instructions.  
- If you cannot reach your gas supplier, call the  
fire department.  
Burner Tray:  
CAUTION: Hot while in operation. Do not touch. Severe Burns may result. Due to high  
surface temperatures keep children, clothing and furniture, gasoline and other liquids  
having fammable vapors away. Keep burner and control compartment clean. See installation  
and operating instructions accompanying appliance.  
The burner tray is positioned directly under the  
burner tube(s) and logs and is made of a differ-  
ent gauge material from the rest of the rebox  
and body. Therefore, the varying thicknesses of  
steelwillexpandandcontractatslightlydifferent  
rates which can cause "ticking" and "cracking"  
sounds. You should also be aware that as there  
are temperature changes within the unit these  
sounds will likely re-occur. Again, this is normal  
for steel reboxes.  
LIGHTING INSTRUCTIONS  
STOP! Read the safety information above on this label.  
1) Plug the power cord into a power outlet.  
3) After approximately 8 seconds the spark ignition  
system will spark for 8 seconds to light the main  
burner.  
2) Press and release the ON/OFF switch once to start  
the unit. The LED will be lit.  
4) If the main burner does not light, repeat step 2 to  
restart.  
Gas Control Valve:  
As the gas control valve turns ON and OFF, a  
dullclickingsoundmaybeaudible,thisisnormal  
operation of a gas regulator or valve.  
TO TURN OFF GAS APPLIANCE  
1) Press the ON/OFF switch once.  
2) The LED will flash.  
3) Turn off all electric power to the unit if service is  
to be performed.  
Unit Body/Firebox:  
Different types and thicknesses of steel will  
expand and contract at different rates resulting  
in some "cracking" and "ticking" sounds will be  
heard throughout the cycling process.  
You may shut off the pilot during prolonged non use periods to conserve fuel.  
918-247b  
DO NOT REMOVE THIS INSTRUCTION PLATE  
RESETTING THE UNIT  
WARNING:  
DO NOT SPRAY AEROSOLS IN THE VICINITY OF  
THIS APPLIANCE WHILE IN OPERATION.  
If the appliance goes to 'lockout', the system  
will have to be reset by depressing the reset  
button - located behind bottom louver.  
*Important: Wait at least 5 min for any un-  
burned gas to clear before resetting the  
appliance.  
1) Open the bottom louver on the unit.  
2) Press and release the reset button - once.  
The button is located near the gas valve.  
3) Wait for approximately 3 seconds - the  
pilot sparks can be heard and seen. It will  
take approximately 2 to 3 seconds for the  
flame to be lit.  
"Appliances incorporating a live fuel effect, and designed to  
operate with luminous ames, may exhibit slight carbon  
deposition."  
NOTE: Wait 30 seconds between reset  
attempts.  
24  
Regency IG34 Gas Inbuilt Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
WARNING: CHILDREN AND  
ADULTS SHOULD BE ALERTED  
TO THE HAZARDS OF HIGH  
SURFACE TEMPERATURE AND  
SHOULD STAY AWAY TO AVOID  
BURNS OR CLOTHING IGNITION.  
YOUNG CHILDREN SHOULD BE  
CAREFULLYSUPERVISEDWHEN  
THEY ARE IN THE SAME ROOM  
AS THE APPLIANCE.  
MAINTENANCE  
INSTRUCTIONS  
LOG REPLACEMENT  
Theunitshouldneverbeusedwithbrokenlogs.  
Unplugthepowercordandallowtheunittocool  
beforeopeningdoortocarefullyremovethelogs.  
Ifforanyreasonalogshouldneedreplacement,  
you must use the proper replacement log. The  
position of these logs must be as shown in the  
diagram under Log Installation.  
Any maintenance required accessing the  
glass door of the unit must be performed  
by an authorized service person.  
1) Always unplug the power cord before  
cleaning. For relighting, refer to lighting  
instructions. Keep the burner and control  
compartment clean by brushing and vacu-  
uming at least once a year. When cleaning  
the logs, use a soft clean brush as the logs  
are fragile and easily damaged.  
Note: Improper positioning of logs may  
createcarbonbuild-upandwillalter  
the unit’s performance which is not  
covered under warranty.  
2) Clean glass (never when unit is hot), appli-  
ance, louvres, and door with a damp cloth.  
Never use an abrasive cleaner. The gold  
louvres (and optional gold door) may be  
scratched if abrasives are used to clean  
them.  
DOOR GLASS  
REPLACEMENT  
Your Regency stove is supplied with high tem-  
perature, 5 mm Neoceram ceramic glass that  
willwithstandthehighestheatthatyourunitwill  
produce. Intheeventthatyoubreakyourglass  
by impact, purchase your replacement from an  
authorisedRegencydealeronly, andfollowour  
step-by-step instructions for replacement.  
The heater is nished in a heat resistant  
paint and should only be renished with  
heat resistant paint (not with wall paint).  
Regency uses StoveBright Paint - Metallic  
Black #6309.  
CAUTION: ANYSAFETYSCREEN  
ORGUARDREMOVEDFORSERV-  
ICING AN APPLIANCE MUST BE  
REPLACED PRIOR TO OPERAT-  
ING THE APPLIANCE.  
3) Make a periodic check of burner for proper  
position and condition. Visually check the  
ameoftheburnerperiodically,makingsure  
the ames are steady; not lifting or oating.  
If there is a problem, call an authorized  
service person.  
WARNING: do not operate appli-  
ance with the glass front removed,  
cracked or broken. Replacement  
of the glass should be done by  
a licensed or authorised service  
person.  
CLOTHING OR OTHER FLAM-  
MABLE MATERIALSHOULD NOT  
BE PLACED ON OR NEAR THE  
APPLIANCE.  
4) The appliance and ueing system must be  
inspected before use, and at least annu-  
ally, by an authorized eld service person,  
to ensure that the ow of combustion and  
ventilation air is not obstructed.  
Flush Glass Replacement  
Slide old glass out of the side frames and  
replace with new glass.  
During the annual service call, the burners  
should be removed from the burner tray  
and cleaned. Replace the embers - do not  
block the burner ports.  
DO NOT USE THIS APPLIANCE  
IF ANY PART HAS BEEN UNDER  
WATER. IMMEDIATELY CALL AN  
AUTHORIZED SERVICE TECHNI  
CIAN TO INSPECT THE APPLI-  
ANCE AND TO REPLACE ANY  
PARTOFCONTROLSYSTEMAND  
ANY GAS CONTROL WHICH HAS  
BEEN UNDER WATER.  
GLASS GASKET  
5) Keep the area near the appliance clear and  
free from combustible materials, gasoline  
and other ammable vapours and liquids.  
If the glass gasket requires replacement use  
glass gasket (Part # 936-155).  
6) Verify proper operation after servicing.  
Regency IG34 Gas Inbuilt Fireplace  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
FAN MAINTENANCE  
To Remove Fan:  
1) Turn the unit off and allow it to cool to room temperature,  
2) Unplug or disconnect power source to stove.  
3) Open the bottom louvre.  
4) Remove screws that secure protective screen.  
5) Remove door frame and screen  
6) Remove the ECS harness from the back clip.  
7) Pull out the ECS box.  
NOTE: The ECS box is held in place with velcro.  
8) Remove the 2 screws that secure the fan in place.  
9) Carefully slide the fan to the front, rotate it 45 degrees and slide it out simultaneously with the ECS box.  
Resistor  
Connectors  
Fan  
Connectors  
Fan Ground  
Cable  
10) Disconnect all the connectors from the fan and resistor.  
11) Remove the fan ground cable.  
12) Reverse the above steps to install the new fan.  
26  
Regency IG34 Gas Inbuilt Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
VALVE ASSEMBLY REPLACEMENT  
1) Unplug or disconnect the power source to the stove and shut off gas supply.  
2) open bottom louvre and remove protective screen.  
3) Remove the door frame and safety screen.  
4) Remove the glass door, logs, and black or stainless inner liner, if installed.  
5) Remove the rear log tray, burner and grate.  
6) Disconnect gas line from the valve.  
7) Remove the rebox base plate by removing the 10 screws which hold it in place.  
8) Remove all the wire connectors from the valve and spark ignitor.  
9) Remove the valve tray assembly.  
10) To replace the valve tray assembly, simply reverse the above steps.  
Regency IG34 Gas Inbuilt Fireplace  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS LIST  
ELECTRONIC COMPONENTS PARTS LIST  
910-936  
910-082  
910-089  
910-088  
910-912  
910-084  
910-527  
910-935  
910-080  
910-083  
910-916  
910-906  
910-514  
910-521, 910-522, 910-523, 910-525  
FG37  
FG38  
FG39 PG33 PG36 HG35 PG121/PG131 IG35 IG34  
PG36D  
910-909 Fan Resistor  
910-936 Intermittent Pilot  
910-082 Direct Spark Ignitor  
910-089 Flame Cable  
910-088 Spark Cable  
910-084 Control Box  
910-527 Manual Control  
910-080 Valve  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
910-521 Control Box Cable (1)  
910-522 Control Box Cable (2)  
910-523 Control Box Cable (3)  
910-525 Control Box Cable (4)  
(1)  
(2)  
N/A*  
(2)  
(2)  
N/A*  
(2)  
(3)  
(4)  
910-912 Ignition Module to Valve Cable  
N/A  
N/A  
N/A  
N/A  
(1)  
910-906 Reset Switch  
N/A  
(1)  
910-083 Ignition Module (1)  
910-922 Ignition Module (2)  
(2)  
(2)  
(2)  
(2)  
(2)  
(2)  
(2)  
910-514 Jumper  
N/A  
N/A  
N/A  
N/A  
N/A  
910-935 Manual Control Switch  
N/A  
*Note: The Control Box Cable wires for the FG38 come separately: 910-502, 910-505, 910-506, 910-507, 910-509  
The Control Box Cable wires for the IG35 come separately: 910-530, 910-504, 910-528  
28  
Regency IG34 Gas Inbuilt Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS LIST  
MAIN ASSEMBLY  
Part #  
Description  
Part #  
Description  
1) 910-169/P Fan Motor (240 V)**  
10) 910-936  
910-947  
Pilot Assy (NG) - 3 ame convertible top  
Pilot Assy (LPG) - 3 ame convertible top  
2) 910-995  
Thermodisc**  
11) 904-240  
904-645  
Orice #37 (NG)  
Orice #51 (LP)  
3) 486-968  
486-967  
LPG Conversion Kit**  
ULPG Conversion Kit**  
12) 336-013  
13) 936-155  
14) 940-307/P Neoceram Glass  
Glass Door Frame  
Gasket Tadpole Tape  
4) 336-574/P Valve Assembly - NG  
336-576/P Valve Assembly - LPG  
5) 910-080  
SIGMA Valve 845  
948-223  
918-793  
Logo Plate  
Manual  
6) 336-001  
Valve Tray Gasket**  
7) 402-526  
8) 336-535  
9) 402-935  
Grate Assembly**  
Burner Assembly - NG/LPG  
Log Set**  
*Not available as a replacement part.  
** Part not shown.  
14  
4
10  
11  
8
12  
Regency IG34 Gas Inbuilt Fireplace  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS LIST  
FACEPLATE ASSEMBLY  
Part #  
Description  
14) 336-914 Faceplate & Trim Complete - Regular  
15) 366-942 Plinth Kit  
16) 336-532 Flush Screen Door**  
*Not available as a replacement part.  
15  
14  
30  
Regency IG34 Gas Inbuilt Fireplace  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY  
Regency® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each  
unit thoroughly before it leaves our door. Regency is pleased to extend this limited lifetime warranty to the original purchaser of a Regency® Product.  
®
The Warranty: Lifetime  
Covered under the agreement are the following components: The combustion chamber, heat exchanger, burner tubes/pans, logs, glass crystals, ceramic spa stones,  
pebbles, brick panels and gold plating (against defective manufacture only) are covered under the Limited Lifetime Warranty for ve (5) years for parts and labour and  
parts only thereafter.  
External casting, surrounds and grills are covered against cracks and warps resulting from manufacturer defects, parts and labour for one (1) year from the date of  
purchase and parts only thereafter.  
Special Finishes - One year on stainless steel panels, nickel overlays, nickel faceplates, brushed nickel and antique copper full screens and doors. You can expect some  
changes in color as the product "ages" with constant heating and cooling. FPI warranties the product for any manufacturing defects on the original product. However,  
the manufacturers warranty does not cover changing colors and marks, ie. nger prints, etc applied after the purchase of the product. Damage from the use of abrasive  
cleaners is not covered by warranty.  
Electrical components such as fans, switches, ignition modules, wiring, thermodiscs, remote control, thermopiles, thermocouples and gas valves are covered for one  
year for parts and labour from the date of purchase.  
The warranty on brass parts is for one year, no labour. The brass is not warranted against tarnishing.  
Repair/replacement parts purchased by the consumer from Regency® after the original coverage has expired on the unit will carry a 90 day warranty valid with a receipt  
only. Any item shown to be defective will be repaired or replaced at our discretion. No labour coverage is included with these parts.  
Conditions:  
All installations must be performed by a qualied gas tter and installed according to all applicable local and national codes. Also, all service work must be carried out  
by a qualied gas service person provided by the selling dealer. It is the responsibility of the installer to ensure that the appliance is ring as per rating plate. Any part  
or parts of this unit which in our judgement show evidence of such defect will be repaired or replaced at Regency®'s option, through an accredited distributor or agent  
provided that the defective part be returned to the distributor or agent Transportation Prepaid, if requested. In areas where there is not an approved service agent or  
the closest approved service agent is situated more than thirty (30) kilometres from the installation, Regency is not obliged to arrange warranty repairs and travel and/  
or additional labour charges will apply.  
Porcelain/Enamel - Absolute perfection is neither guaranteed nor commercially possible. Any chips must be reported and inspected by an authorised dealer within three  
days of installation. Reported damage after this time will be subject to rejection.  
It is the general practice of Regency® to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to Regency  
and evaluated fro manufacturer defect.  
At all time Regency reserves the right to inspect product in the eld which is claimed to be defective.  
All claims must be submitted to Regency® by authorised selling dealers. It is essential that all submitted claims provide all of the necessary information including customer  
name, purchase date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.  
Exclusions:  
This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim. It does not cover installation and operational related problems such as  
over-ring, downdrafts or spillage caused by environmental conditions, nearby trees, buildings, hilltops, mountains, inadequate ueing or ventilation, excessive offsets,  
negative air pressures caused by insufcient make up air, mechanical systems such as furnaces, fans, clothes dryers etc.  
Embers, rockwool, gaskets, door handles and paint are not covered under the terms of this warranty policy.  
Regency® will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.  
Performance problems due to operator error will not be covered by this warranty policy.  
The warranty does not extend to any part or parts which show evidence of misuse or abuse, neglect, accident, lack of maintenance, or improper installation.  
Products made by other manufacturers and used in conjunction with the operation of this appliance without authorisation from Regency®, may nullify your warranty on  
this product.  
Regency shall in no event be liable for any special, indirect consequential damages of any nature whatsoever which are in excess of the original purchase price of the  
product. Any alteration to the unit which causes sooting or carboning that results in damage to the exterior facia is not the responsibility of FPI.  
SUBJECT TO CHANGE.  
DISTRIBUTORS:  
Western Australia  
Air Group Australia  
28 Division St  
Eastern Australia  
FIREPLACE PRODUCTS AUSTRALIA PTY. Ltd.  
21-23 South Link  
Welshpool WA 6106  
Dandenong, VIC 3175  
NOTE: PLEASE RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY VERIFICATION  
INCORRECT INSTALLATION, ELECTRICAL SURGES WHICH MAY CAUSE DAMAGE TO ELECTRICAL COMPONENTS/ GAS VALVES OR  
GAS PRESSURE SETTINGS ARE NOT COVERED BY WARRANTY  
A SERVICE OR CALL OUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES.  
Regency IG34 Gas Inbuilt Fireplace  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIREPLACE PRODUCTS AUSTRALIA PTY. LTD.  
21-23 SOUTH LINK, DANDENONG SOUTH  
VICTORIA, 3175  
AUSTRALIA  
© Copyright 2009, FPI Fireplace Products International Ltd. All rights reserved.  
Printed in Canada  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Radio Shack Stereo Amplifier 32 2054 User Guide
Radio Shack Weather Radio 63 1039 User Guide
Remington Hair Dryer DC 1880 User Guide
Rival Can Opener CN738 User Guide
RocketFish Video Gaming Accessories RF GPS31104 User Guide
Rockford Fosgate Car Speaker RFP 1408 User Guide
Ryobi Outdoor Trimmer RY30120 User Guide
Samsung Cooktop SNH1010N User Guide
Samsung Security Camera SCC 5399N User Guide
Sanyo Security Camera VCC XZ200P User Guide