Raypak Boiler 751 1501 User Guide

Job:  
ADB™ - Type H  
Hydronic Heating Boilers  
Engineer:  
Contractor:  
Prepared By:  
Model:  
Models 751-1501  
Date:  
Indoor/Outdoor:  
100% Factory Fire Tested  
Efficiency: 84%  
Maximum Outlet Temperature: 230°F  
Minimum Non-Condensing Inlet Temperature: 105°F  
Thermal Shock Proof Heat Exchanger  
Footprint: Less Than 5-1/2 ft2  
Limited Twenty-Year Thermal Shock Warranty  
Limited Ten-Year Heat Exchanger Warranty  
Ten-Year Unconditional Burner Head Warranty  
Operation Status Center and Full Diagnostic Panel  
Heat Exchanger  
ƒ Bronze Headers  
Gas Train  
ƒ Fuel  
Temperature Controls  
B-20 Single-Stage Controller,  
100-200°F  
ƒ ASME Inspected and Stamped  
160 PSIG Working Pressure  
ƒ National Board Approved  
ƒ Copper-finned Tubes  
ƒ ASME Steel Tube Retainer  
ƒ Silicone High Temp O-Rings  
ƒ 60 PSIG ASME Pressure Relief  
Valve  
Natural Gas  
Propane (Models 751 & 1001)  
ƒ Manual Gas Shut-off Valves  
ƒ Gas Pressure Regulator  
ƒ Safety Shut-off Valve  
B-6  
2-Stage Controller, 100-200°F  
B-21 4-Stage TempTracker Digital  
Controller, Loose  
B-23 4-Stage TempTracker Digital  
Controller, Outdoor Reset, Loose  
Y-241 Electronic Sequencer,  
1-4 Stages  
ƒ Firing Control Valve  
ƒ Manual Low Gas Pressure Switch  
ƒ On/Off Firing Mode (H4)  
ƒ Design Certified ANSI Z21.13/  
CSA 4.9  
ƒ Temperature and Pressure Gauge,  
Shipped Loose  
Y-281 Electronic Sequencer,  
5-8 Stages  
Control  
Construction  
Additional Safety Controls (Optional)  
F-10 Low Water Cut-off,  
Remote Probe  
ƒ 120V, 60Hz, Power Supply  
ƒ 120/24V 60Hz Transformer  
ƒ 100% Pilot Shutoff/Lockout  
ƒ Electronic Intermittent Ignition Pilot  
(IID)  
ƒ Indoor/Outdoor Construction  
ƒ Front Controls Enclosed  
ƒ PolyTuf Powder Coat Finish  
ƒ Connections (Water, Electrical,  
Gas)  
S-2  
Manual High Gas Pressure  
Switch  
ƒ High Limit Control, Manual Reset  
ƒ High Limit Control, Auto Reset  
ƒ On/Off Switch  
Rear – Standard  
Right Side – Option A-8  
Regulatory Agency Requirements  
C-5 Ignition Lockout Module  
Venting  
ƒ Vent Location  
ƒ Flow Switch  
ƒ Blocked Vent Pressure Switch  
ƒ Combustion Air Proving Switch  
ƒ Time Delay Pump Off Control  
ƒ Central Point Wiring Diagnostics  
Panel  
Rear – Standard  
Other Equipment  
Condensing Heat Exchanger  
Pump  
Right Side – Option Z-2  
ƒ Vent Termination Cap  
Outdoor - Option D-11  
Indoor, Horizontal – Option D-15  
Indoor, Vertical (by others)  
Burner  
ƒ Aerodynamically Stabilized  
Non-Clog Burner  
ƒ Ultra-Low NOx: Less than 30 PPM  
Catalog No.: 2000.36G  
Effective: 2-1-08  
Replaces: 5-1-05  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Q See Digital Camera QD28414 User Guide
Rosen Entertainment Systems GPS Receiver DS HY0710 User Guide
Ryobi Saw TS1302 User Guide
Samsung Blu ray Player BD E5300 ZA User Guide
Samsung Computer Monitor TC240 2 8 User Guide
Samsung DVR SRD 870 User Guide
Sanyo CD Player ECD T1137S User Guide
Sanyo Flat Panel Television ST 21KS2 User Guide
Sceptre Technologies Computer Monitor E22 User Guide
Schneider Electric Drums VSE 002 User Guide