Raritan Computer Switch P2UMT1664M User Guide

Paragon® II  
Quick Installation and Setup Guide  
Congratulations on your purchase of Paragon II devices comprising of analog Keyboard/Video/Mouse (KVM) switches and  
accessory devices that enable users to access and control multiple servers from a set of keyboard, mouse and monitor.  
The document provides instructions for basic installation, initial login and channel access. For more detailed information on  
the Paragon II products, consult the User Guide accessible from the accompanying User Manuals and Quick Setup  
Guides CD or Raritan website's Firmware and Documentation webpage  
Note: The Ethernet port on the Paragon switch is hard coded (not configurable) and supports only 10-BaseT/half duplex.  
Paragon II cover 4 basic types of devices:  
Main Switching Unit (Main Unit)  
Stacking Unit  
Models: P2UMT242, P2UMT442, P2UMT832M, P2UMT1664M  
Models: P2UMT832S, P2UMT1664S  
User Station  
Computer Interface Module (CIM)  
Models: P2UST, P2EUST, P2EUST/C  
Models: P2CIMAPS2, P2CIMAUSB, P2CIMASUN, and more  
Paragon II QSG  
1
QSG-P2-0J-v4.5-E y 255-30-6010-00  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Secure the cable-support bar to the front end of the side  
brackets, near the side brackets' “ears,” using two of the  
included screws.  
Note: Users and servers can be located up to 1000 feet (304 m)  
apart. However, try to limit the cable length between the CIM  
and Paragon II switch to less than 100 feet (30.5 m) for optimal  
video quality, and if possible, limit the total cable length  
between the user and target server to less than 500 feet (152 m)  
for good video quality.  
2. Slide the user station or KVM switch between the side  
brackets, with its rear panel facing the cable-support bar,  
until its front panel is flush with the back edges of the side  
brackets.  
3. Secure the user station or switch to the side brackets using  
the remaining included screws (three on each side).  
Step (A): Connect Stacking Units  
If your Main Unit supports the use of Stacking Units, such as  
P2-UMT832M, you can connect compatible Stacking Units to  
expand the number of channel ports in the system.  
4. Mount the entire assembly in your rack and secure the side  
brackets' ears to the rack's front rails with your own screws,  
bolts, cage nuts, and so on.  
5. When connecting cables to the rear panel of the user  
station or switch, drape them over the cable-support bar.  
To connect one or more Stacking Units  
1. Connect the power cord to the Main Unit.  
2. Connect the power cord to the Stacking Unit.  
Rear rackmount of a Paragon switch  
3. Depending on the Stacking Unit you purchased, use one or  
two stacking cables to connect the Stacking Unit to the  
Main Unit.  
a. For connecting P2-UMT832S to P2-UMT832M:  
ƒ
Plug one end of a stacking cable into the  
port—Expansion Port Out—on the Stacking Unit.  
ƒ
Plug the other end of the cable into the  
port—Expansion Port—on the Main Unit.  
Rear rackmount of a user station  
b. For connecting P2-UMT1664S to P2-UMT1664M:  
ƒ
Plug one end of the stacking cable into "Expansion  
Port Out A" on the Stacking Unit and the other end  
of the cable into the lower "Expansion Port In" on the  
Main Unit.  
ƒ
Plug one end of the other stacking cable into  
"Expansion Port Out B" on the Stacking Unit and the  
other end of the cable into the upper "Expansion  
Port In" on the Main Unit.  
4. (Optional) You can cascade up to three P2-UMT832S  
Stacking Units for a P2-UMT832M Main Unit. To add more  
Stacking Units, follow this procedure:  
QS Rule  
Basic Installation  
Ensure that you have turned OFF all servers and Paragon II  
devices prior to installation. Installing a basic Paragon II system  
involves these steps.  
a. Plug one end of a stacking cable into the  
port—Expansion Port In—on the last Stacking Unit  
connected to the Main Unit.  
ƒ
Step (A): Connect Stacking Units to a Main Unit  
(Optional)  
b. Plug the other end of the cable into the port—Expansion  
Port Out—on the newly added Stacking Unit.  
ƒ
ƒ
Step (B): Connect User Stations to the Main Unit  
Step (C): Connect Servers to Paragon II Main and  
Stacking Units  
c. Connect a power cord to the newly added Stacking Unit.  
Paragon II QSG  
3
QSG-P2-0J-v4.5-E y 255-30-6010-00  
Download from Www.Somanuals.com. All Manuals Search And Download.  
d. Repeat Steps a to c if you want to add one more  
Stacking Unit.  
3. Connect a PS/2 or USB keyboard, mouse, and a VGA  
monitor to the user station.  
5. Turn on all Paragon II devices.  
6. Set the total number of connected Stacking Units on the  
front panel of the Main Unit.  
a. Press the FUNC button to activate the Function Menu.  
b. Press the U and V buttons to select "Stacking  
Support."  
c. Press the ENT button to confirm your selection.  
d. Press the U and V buttons to select the total number of  
Stacking Units—3 maximum for P2-UMT832M or 1  
maximum for P2-UMT1664M.  
e. Press the ENT button to save the setting.  
Note: P2-EUST/C provides USB ports only for keyboard  
and mouse.  
7. Set a unique Stacking Unit ID on the front panel of each  
Stacking Unit.  
a. Press the FUNC button to activate the Function Menu.  
b. Press the U and V buttons to select "Set Stack ID."  
c. Press the ENT button to confirm your selection.  
4. Turn on the monitor.  
5. Repeat Steps 1 to 4 for all other user stations you want to  
connect to remaining User Ports.  
d. Press the U and V buttons to assign the numeric ID.  
The user station does not support the use of a VGA-to-DVI  
converter.  
The guideline of ID assignment is:  
ƒ
ƒ
ƒ
Assign 1 as the ID for the first Stacking Unit, which is  
directly connected the Main Unit.  
Assign 2 as the ID for the second Stacking Unit,  
which is connected to the first Stacking Unit.  
Step (C): Connect Servers  
To connect one or more servers  
Assign 3 as the ID for the third Stacking Unit, which  
is connected to the second Stacking Unit.  
1. Connect a Paragon II CIM to the Main or Stacking Unit.  
e. Press the ENT button to save the setting.  
a. Plug one end of a Cat5 UTP cable into Channel Port  
number 1 on the back of the Main Unit or any connected  
Stacking Unit.  
8. Turn OFF all Paragon II devices.  
9. Turn on the Stacking Unit first. If there are multiple Stacking  
Units, turn on the Stacking Units from the last one to the first  
one in sequence.  
b. Plug the other end of the cable into the RJ45 port of the  
CIM.  
10. Turn on the Main Unit.  
Step (B): Connect User Stations  
To connect one or more user stations  
1. Connect a user station to the Main Unit.  
2. Depending on the CIM model you purchased, plug the  
connectors of the CIM into a server's PS/2 or USB  
keyboard, mouse, and VGA ports.  
a. Plug one end of a Cat5 UTP cable into User Port  
number 1 on the back of the Main Unit.  
b. Plug the other end of the cable into the RJ45 port on the  
back of the user station.  
2. Connect a power cord to the user station and turn it on.  
Paragon II QSG  
4
QSG-P2-0J-v4.5-E y 255-30-6010-00  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Channels connecting to servers appear in green. At first  
there are no names for any servers so all Name fields are  
blank.  
Tip: If the server provides a DVI-D connector instead of a  
VGA port, Raritan recommends that you connect the CIM  
to the server using a Smart View DVI-to-VGA (female to  
female) converter (DV-101). Note that currently only the  
Smart View DVI-to-VGA converter has been tested and is  
officially supported by Raritan for use with Paragon II.  
Note: The only exception is IBM BladeCenter chassis.  
Paragon II shows a default name “IBM-Blade” for the  
device.  
3. Turn on the server.  
5. Press Æ or Å on the keyboard to move the highlight to one  
4. Repeat Steps 1 to 3 for all other servers you want to  
connect to remaining Channel Ports.  
of the green channels and press Enter.  
6. Now you can view and control the chosen server with the  
keyboard and mouse.  
QS Rule  
Initial Verification  
7. Press the Scroll Lock key twice QUICKLY to activate the  
OSUI, and do one of the following:  
To verify that the server connected to the Paragon  
system can be operated:  
ƒ
To choose another green channel for verification,  
repeat Step 5.  
1. Turn on all devices in the Paragon II system.  
ƒ
To log out of the system, press F9.  
2. The Login screen of the On-Screen User Interface (OSUI)  
is displayed on the monitor connected to the user station.  
QS Rule  
Video Gain Adjustment  
A video-gain adjustment is available to focus the video image,  
which can be especially useful if you are using an LCD  
flat-panel monitor. Please note that you must access each  
channel individually to adjust that channel's video gain.  
To make the video-gain adjustment  
1. Press the hot key (default: Scroll Lock) twice QUICKLY to  
activate the Selection Menu.  
3. Type your user name and password in the appropriate  
fields and press Enter. For example, if you are the  
administrator:  
2. Press the + and - (plus- and minus-sign) keys on the  
keypad of your keyboard to adjust the video image until it  
appears to be in focus.  
a. Type admin in the User Name field and press Enter.  
ƒ
For P2-UST, the video-gain range is -15 to +15.  
b. Type raritan (the default password; all lowercase) in  
the Password field and press Enter. Note the  
password is case-sensitive.  
ƒ
For P2-EUST or P2-EUST/C, the video-gain setting is  
named "AGC," and its range is 0 to +6.  
Tip: You can also type any user name for regular users.  
The factory-default user names for regular users are  
user01 through up to user15, depending on the model of  
your Main Unit. By default, there are no passwords for  
these user names.  
3. Press Esc or Enter to quit the OSUI and save the video  
4. The Selection Menu appears.  
setting.  
4. To adjust another channel's video-gain setting, access it  
and then repeat Steps 1 to 3.  
QS Rule  
Multi-Platform CIM Table  
PS/2 CIMs  
CIM model  
PS/2  
VGA  
Local  
connector connector ports  
P2CIM-APS2  
HD15  
HD15  
HD15  
V
V
V
P2CIM-APS2DUAL  
P2CIM-APS2-B  
Paragon II QSG  
5
QSG-P2-0J-v4.5-E y 255-30-6010-00  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CIM model  
PS/2  
VGA  
Local  
CIM model  
Automatic  
skew  
Support Support  
for IBM for card  
connector connector ports  
compensation Blade  
servers  
reader  
UKVMC  
HD15  
V
V
P2CIM-APS2-B  
P2CIM-AUSB  
V
V
USB CIMs  
CIM model  
V
USB  
VGA  
Local  
connector connector ports  
P2CIM-AUSBD  
UAL  
V
P2CIM-AUSB*  
HD15  
HD15  
HD15  
HD15  
V
V
V
V
P2CIM-AUSB-B  
P2CIM-AUSB-C  
V
V
V
P2CIM-AUSBDUAL*  
P2CIM-AUSB-B  
P2CIM-AUSB-C*  
V
P2CIM-ASUN  
V
* These USB CIMs also support Sun servers via the SUN USB  
ports.  
Serial CIMs  
CIM model  
Serial  
VGA  
Local  
(RS-232)  
connector  
connector ports  
P2CIM-SER  
P2CIM-SER-EU  
AUATC  
V
V
V
V
HD15  
HD15  
HD15  
HD15  
V
P2CIM-PWR  
(for the power strip)  
SUN CIMs  
CIM model  
SUN MINI VGA  
Local  
DIN8  
connector ports  
connector  
P2CIM-ASUN  
USKVMC  
V
HD15  
V
13w3/  
HD15  
V
CIMs with Special Functions  
CIM model  
Automatic  
skew  
Support Support  
for IBM for card  
compensation Blade  
servers  
reader  
P2CIM-APS2  
V
P2CIM-APS2D  
UAL  
V
Paragon II QSG  
6
QSG-P2-0J-v4.5-E y 255-30-6010-00  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Quantum Network Card PX500 Series User Guide
Radio Shack Cordless Telephone ET 537 User Guide
RSA Lighting Indoor Furnishings 40 DHWH User Guide
Ryobi Saw RJ162VK User Guide
Sakar Digital Camera 52379 User Guide
Samsung Digital Camera Digimax 130 User Guide
Samsung MP3 Player MCD SM45 User Guide
Samsung Speaker PRO SW60P User Guide
Sanyo Camcorder VCC 9300 User Guide
Sanyo Security Camera VCC 4790P User Guide