INSTALLATION MANUAL
PLASMA DISPLAY MOUNT MODEL
3130 E. Miraloma Ave. Anaheim, CA 92806 Phone: 800 368-9700 Fax: 800 832-4888
VISIT US AT WWW.MOUNTS.COM
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety & Precautions
WARNING: Safety precaution measures must be practiced at all times during the installation of this product. Use proper safety gear and tools for the
installations procedure to prevent personal injury or damage to the plasma displays or plasma mounts.
The wall or ceiling structure must be capable of supporting at least five (5) times the weight of plasma display.
If not, the wall or ceiling must be reinforced. Proper installation procedure by qualified personnel as outlined in the installations instructions
must be adhered to. Failure to do so could result in serious personal injury
The entire installation instructions should be fully read and understood, including all of the safety symbols and safety precautions, before
beginning installation. The installation instructions should be read, understood and followed to prevent personal injury or property damage.
Keep these installation instructions in an easily accessible location for future reference.
Indicates that the power plug is to be disconnected from
the power outlet.
Contact Premier Mounts for any questions
Safety precautions must be taken at all times.
Warning and caution in general
A secured structure wooden stud wall must always support the weight or load of the plasma. Always confirm the center of the wood
stud before beginning the installation.
Do not install in locations where there is vibration, movement or danger of impact. Failure to do so could result in plasma cracking or
falling from the wall causing damage and injury.
Do not install near heater, fireplace, direct sunlight or air conditioning or any other source of direct heat energy. Failure to do so may
result in damage to the plasma television and could cause a risk of fire.
At least two qualified people should always perform the installation work. Injury and damage can result from dropping or mishandling
the plasma television.
Mounting structure recommended wood studs, solid-flat concrete, and reinforced metal studs. If installing the mount on other than
wood studs use (commercially available) suitable hardware.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Mount Diagrams
Our PSM flat / tilt mounts are designed for wall or ceiling mounting, or it can mate with any of our popular carts, floor stands or wall arms.
The ultra slim plasma mount stands off the wall just enough for proper, OEM-specified ventilation, yet keeps the plasma close enough for a
clean, seamless look. It allows either vertical (portrait) or horizontal (landscape) display configuration.
UNIVERSAL FLAT MOUNT
19.500
16.000
a
0.500
1.528
Ø0.375 (x4)
PART#:
2.125
0.375
PDB-UWFB
MATERIAL:
12 (GA) CRS
COLOR:
d
c
Black powder coat
8.750
Ø2.500
A.
4.500
Lag bolt access slot.
B.
12.000
14.324
17.500
Mounting points (4.5") used on
installations other than wall mounting.
C.
8.750
Access hole for power or cables.
D.
b
M6 security screw mounting points
used on installations other than flat
wall mounting.
1.528
4.500
10.750
0.750
2.125
1.750
0.104
0.688
e
UNIVERSAL TILT MOUNT
19.771
16.000
1.250
5.460
2.865
F
PART#:
PSB-TBP
1.000
A
1.125
1.750
3.500
MATERIAL:
12 (GA) P & O
COLOR:
d
Black powder coat
8.000
A.
Lag bolt access slot.
E.
5.000
4.500
Worm drive
F.
18.500
Locking pins
G.
8.000
Access hole for power or cables.
H.
Mounting points (4.5") used on
installations other than wall mounting.
3.250
4.500
5.460
16.000
b
c
PSM SERIES MOUNT
PART#:
PDB-442
MATERIAL:
12 (GA) P & O
COLOR:
Black Powder coat
Note: The PDB-Series bracket mates
to the universal PDB-UWFB flat
mount and the universal PSB-TBP tilt
mount.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts List
Standard hardware
QTY
SIZE
DESCRIPTION
6 (Tilt) – 4 (Flat)
5/16” Dia
Lag bolts
1
1
2
ꢀ
PSM series mount
Flat / Tilt mount
ꢀ
M6 x 12 (mm) Phillip security
screws
Used for additional security on
tilt mounts, mobile carts, floor
stands and ceiling mounts
Installations instructions
Bubble level
1
1
ꢀ
ꢀ
PSM-Series Mounting hardware
QTY
SIZE
DESCRIPTION
PSM-Mount
6
4
6
8
6
6
6
6
8
8
6
8
6
4 – 4
6
4 – 2
8
6
6
•
6
2
2
6
6
6
6
M5 x 16
Phillip screws
Phillip screws
Phillip screws / Flat washers / Split washers
Phillip screws
Phillip screws / Flat washers / Split washers
Phillip screws
Phillip screws
Phillip screws
Phillip screws
Phillip screws
Phillip screws
Phillip screws
Phillip screws
Phillip screws / Hex bolts
Phillip screws
Hex screws / Hex bolts / Flat washer
PSM-313
PSM-375
PSM-401
PSM-402
PSM-410
PSM-421
PSM-423
PSM-424
PSM-425
PSM-426
PSM-427
PSM-428
PSM-432
PSM-460
PSM-478
PSM-499
PSM-500
PSM-501
PSM-502
PSM-532
PSM-540
PSM-542
PSM-550
PSM-570
PSM-610
PSM-615
PSM-783
PSM-442
M6 x 12
M8 x 20
M6 x 12
M5 x 16
M5 x 12
M5 x 10
M5 x 12
M4 x 12
M5 x 12
M6 x 16
M8 x 12
M5 x 16
M5 x 35 – M4 x 12
M6 x 12
M5 x 50 / M10 x 25
M5 x 20
M8 x 20
M8 x 20
•
Phillip screws / Flat washers / Split washers
Phillip screws
Phillip screws
•
M8 x 30
M5 x 12
M5 x 12
M8 x 30
M8 x 16
M8 x 10
M6 x 12
M8 x 30
Phillip screws
Phillip screws
Phillip screws
Phillip screws
Phillip screws / Flat washers / Split washers
Phillip screws
Phillip screws
4
Phillip screws / Flat washers / Fender washer / .5” nylon spacers
TOOLS & SUPPLY NEEDED
o
o
o
o
o
o
o
o
o
Phillips screwdriver
Drill gun
Soft material or a blanket
Pencil
¼" drill bit
Level
Measuring tape
Wrench with a 1/2" socket
Stud finder
(Optional) Installation Hardware
o
o
1/4"-3/8" Toggler bolts: Used for hollow concrete block wall mounting.
5/16"-3/8" Wedge anchors: Used in solid brick or minimum-rated (3000psi) solid concrete.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
(Optional) ceiling adapters
AST-2446: 1½" (Adjustable height suspension adapter) - Offering height adjustment in 1¼" increments, between 24" and 46"
(12" - 24", if you cut down), this suspension adapter mates with the single display swivel adapter and 1½" (NTP) pipe.
AST-2446/2: 2" (Heavy-duty adjustable height suspension adapter) - Offering height adjustment in 1¼" increments, between 24" and 46"
(12" - 24", if you cut down), this suspension adapter mates with the dual display swivel adapter and 2" (NTP) pipe.
PSD-S: 1½" (Single display swivel adapter) – This adapter could be mated with any two of out ultra slim flat or tilt plasma mounts to allow 360° swivel for a
ceiling installation. It works with 1½" threaded (NTP) pipe or AST-2446.
PSD-D: 2" (Dual display swivel adapter) - This adapter could be mated with any two of out ultra slim flat or tilt plasma mounts to allow 360° swivel for a ceiling
installation of two back to back displays. It works with 2" threaded (NTP) pipe or AST-2446/2.
PSD-PVW1: 1½" (Single display pole adapter) – Attach this adapter directly to any of the flat or tilt plasma mounts, and slide it over a 2" scheduled 40 steel
pipe, then secure at any height with two (2) tension-locked bolts.
PSD-PVW2: 2" (Dual display pole adapter) – Attach any two (2) of the flat or tilt plasma mounts back to back with this adapter, and slide it over a 2" scheduled
40 steel pipe, then secure at any height with two (2) tension-locked bolts.
A
B
Plasma display
PSM-Mount
EXAMPLE PLASMA FOR ILLUSTRATION PURPOSES ONLY
C
D
PSM-Hardware
(See chart on pg 5)
M10 x 12 (mm) Hex
screws, flat washers
(4,4,8 Pack)
Ceiling installation
assembly
E
F
PSB-UWFB Universal flat
mount
M6 Security screws used
on tilt, ceiling, cart, floor
stand applications.
PSB-TBP Universal tilt
mount
AST-2446 adjustable
suspension post for single
display mounting or
AST-2446/2 adjustable
suspension post for dual
display mounting.
PSD-S Single mounting
adapter
G
H
I
J
K
PSD-D Dual mounting
adapter
1½" (NTP) For single
ceiling display installations
or 2" (NTP) For dual
ceiling installations
Horizontal to vertical mounting
Note: The M6 x 12 (mm) Security screws
couldbeusedfor additional safety.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the mounting bracket
WARNING : Proper installation procedure by qualified personnel as outlined in the installation instructions must be adhered to. Failure to do so could
result in serious personal injury and possible damage to the plasma display.
Step 1
CAUTION: The plasma displays are fragile and heavy. At least two (2) qualified personnel are strongly recommended for the installation of this product.
Invert the plasma display and set it on a soft, flat surface to prevent any damage to the plasma display. See fig 1.
EXAMPLE PLASMA FOR ILLUSTRATION PURPOSES ONLY
Top of the plasma
display
Inverted plasma
display
Bottom of the
plasma display
Soft and flat surface
blankets, foam, cloth
etc.
Step 2
CAUTION: The plasma displays are fragile and heavy. At least two (2) qualified personnel are strongly recommended for the installation of this product.
Locate the mounting points found on the back of the plasma chassis, align the mounting holes from the mounting bracket to the holes on the chassis. Arrow found
on the PSM mount must always be pointing to the top of the plasma display before securing it to the chassis. Secure the mounting bracket to the plasma display by
using the hardware specified on the parts list. CAUTION: Do not over tighten the mounting hardware. See fig 2.
WARNING: Do not use the drill gun to secure the screws to the plasma display. A Phillips head screwdriver is preferred.
PSM-series
mount
Mounting hardware
(see chart on pg 5)
Inverted plasma
display
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the mounts
Step 3
Securing the flat mount
CAUTION: The plasma displays are fragile and heavy. At least two (2) qualified personnel are strongly recommended for the installation of this product.
All plasma models vary depending on the manufacturer and some are centered and others are not. Please verify that your plasma mounting points from the back of the chassis are
centered before installing the universal back plate.
Select the area where the plasma will be installed and make sure it can support the weight standards (see warning on page 3). Locate the 16" wood stud centers behind the wall using
a (commercially available) stud finder and mark the center of the studs when found. Set the mounting bracket to the wall and mark the desired height by marking the center of the
universal flat mount.
Note: Same installation process applies to the PSM-Tilt series. See fig 3.
Note: Pre drill before the securing the
Caution: Do not over tighten the 5/16" lag bolts
5/16" lag bolts.
Wall structure
Desired height
marking
Universal flat
mount
16"
Stud centers
marking
Adjusting the
mount
CENTER
OF
VIEWING
HEIGHT
Wood studs behind
the wall structure
floor
floor
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Securing the flat mount or tilt mount
To determine the desired viewing height, use the center slot opening in the wall mount as a center reference for the plasma television when mounted. Once the height is determined,
use the bubble level to insure that the bracket is level. Next, using a pencil, mark the four (4) lag bolt slot openings on the mounting bracket. Before continuing, confirm the marks are
located on the center of the studs.
Drill 1/4" pilot holes on the four (4) markings on the wall. Raise the universal flat or universal tilt bracket and have someone hold it in place (arrow side away from the wall and
pointing up). Put the lag bolt through the flat washers. Screw the lag bolt through the upper left slot opening into the 1/4" pilot hole. Confirm that the wall mount is still leveled and then
screw a lag bolt to the upper right side slot opening into the 1/4" pilot hole. Then install the remaining two lag bolts tightly into the wall studs in the lower left and right slot openings on
the wall mount.
Lateral movement of approximately 1½" for final positioning is now possible. Make any positioning changes then secure the lag bolts. See fig 4.
Flat washers
Lag bolts
Universal flat
mount
Marking on wall
Drill gun with a
1/4" drill bit
Access holes
Wall structure
Wood studs behind
the wall structure
floor
floor
Electrical
Step 4
All electrical wiring components should be installed at this time to ensure that the plasma display has enough power sources.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Securing the mount
Step 5
Warning: The plasma display is heavy and 2 people are needed to lift and install it. Failure to do so could result in serious personal injury.
Before placing the plasma on the wall recheck all hardware for proper tightness and security. Before installing, become familiar with the way the plasma mount attaches to the wall
mount. Align the four (4) tab openings to the four (4) receiving tabs on the flat back plate. When all four (4) the tabs are aligned slide the plasma down, right and down again to lock the
mounts together. Make sure all (4) tab openings are interlocked with the receiving tabs before letting go of the plasma. See fig 5.
Caution: All four (4) receiving tab openings from the
mounting bracket must be locked to the tabs found on
Caution: The plasma display is heavy and 2 people are needed to lift and
the flat back plate before letting go of the plasma
display. See the diagram on the left to see the
interlocked tab.
install it. Failure to do so could result in serious personal injury.
Locked tab
Securing tabs
Universal flat
mount
PSM-series
mount
Align the tabs and
Tab openings
push the plasma
as shown on
arrows to lock in
place
Plasma display
Wall structure
Plasma display
Wall structure
Additional security (Does not apply to flat wall mounting)
Step 6
For additional security gradually tilt the bracket forward using a Phillips screwdriver. Secure the two (2) M6 x 12 (mm) Phillips screws (screws) see fig 6. Do not over tighten the screws.
Position the bracket to the desired angle.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
HARDWARE NOTICE
PANASONIC MODELS
PACK 28
USED ON THE FOLLOWING
MODELS
PACK 2
USED ON THE FOLLOWING
MODELS
42" TH42PA20UP
42" TH42PWD4UY, TH42PWD4EX,
PT42P1, 42PD2, TH42PWD3U,
TH42PHD5U, PT42PD4, PT42PHD4P,
TH42PWD5UY, TH42PW5UZ,
TH42PWD6UY
50" TH50PHD3U, PT50PD3P,
TH50PHD3E, TH50PHW3, TH50PD4,
TH50PHD5UY, 50PHW5UZ
If you have any questions contact
Download from Www.Somanuals.com. All Manuals Search And Download.
NEW HARDWARE APPLIES TO
PLASMA MODELS:
NOTICE APPLIES TO PCM (REV 8)
CTM (REV 8) / PSM / PRM MOUNTS.
N E W H A R D W A R E
Fujitsu 50" & 61"
5001, 5002, PDS6101, PDS6001,
PDS6002,P50XCA11UH
P50XCA10WH, P50XCA10HA
P50XCA10UH,P50XCA11WH
P50XCA11AH, P50XCA12WH
P50XCA12EH, P50XCA12AH
P50XCA12UH
Nylon sleeves
Panasonic 42", 50"
TC42P1, PT42PD3P, PT42PD1P,
TC42P1F, PT37P1, TH42PWD3,
TH37PWD4UZ, TH42PWD4UY,
TH42PWD4EX, PT42P1, 42PD2,
TH42PWD3U, TH50PHD3U,
PT50PD3P, TH50PHD3E, TH50PHW3
Runco 42"
½" Nylon spacers
PL42cx,
Toshiba 42", 50"
50HP81, PD42W, PD42W1
ViewSonic 42"
VPW420,
Dwin 50"
HD50
JVC 50"
GDV500PZU
ASSEMBLED
CAUTION!
The nylon sleeves and ½” nylon spacers must ALWAYS be used in order to install plasma bracket on to the
plasma. Failure to do so will result in damaging the plasma internally. This application is required by the plasma
manufacture.
Download from Www.Somanuals.com. All Manuals Search And Download.
|