Planet Technology Switch WGD 800 User Manual

User's Manual  
WGD-800  
8-Port 10/100Mbps  
Managed Ethernet Switch  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. INTRODUCTION  
1.1 Packet Contents  
Check the contents of your package for following parts:  
Ethernet Switch x1  
CD-ROM user's manual x1  
Quick installation guide x1  
19" rack mounting kit x1  
Power cord x1  
Rubber feet x 4  
If any of these are missing or damaged, please contact your dealer immediately, if possible, retain the carton  
including the original packing material, and use them against to repack the product in case there is a need to  
return it to us for repair.  
1.2 How to Use This Manual  
This User Manual is structured as follows:  
Chapter 2, INSTALLATION  
The chapter explains the functions of the Switch and how to physically install the Switch.  
Chapter 3, CONSOLE MANAGEMENT  
The chapter explains how to manage the switch by Console interface.  
Chapter 4, WEB-BASED MANAGEMENT  
The chapter explains how to manage the switch by Web interface.  
Chapter 5, TROUBLE SHOOTING  
The chapter explains how to trouble shooting of the Switch.  
Chapter 6, APPENDIX  
The chapter contains cable information of the Switch.  
In the following section, terms "SWITCH" with upper case denotes the WSD-800 Ethernet switch. Terms with  
lower case "switch" means any Ethernet switches.  
1.3 Product Feature  
8-Port 10/100Mbps TP interfaces  
Complies with IEEE802.3, 10Base-T, IEEE802.3u, 100Base-Tx  
High back-plane bandwidth 1.6Gbps  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Console/Web/SNMP management  
Configuration backup and recovery  
Per port Ingress/Egress bandwidth restriction  
802.1d Spanning tree, 802.1w Rapid Spanning Tree  
Configurable spanning tree aging time, STP port configuration  
4 trunk groups, up to 4 ports per trunk  
Port-based/802.1Q VLAN with 4K VLAN ID  
MAC Binding/Filtering/Learning, configurable MAC Aging time  
8 mappings ID to 4 priority queues, Support MAC/VLAN/802.1p/Port to CoS mapping  
IGMP snooping and IGMP Query mode for Multi-media application  
Statistic Routing Port  
1 to many Ingress/Egress Port mirror and Port analysis  
Broadcast/Multicast/Flooded storm control  
802.1X Port-Based Authentication  
IP Stack Technology supports up to 8unit switch stack for centralize management  
1.4 Product Specification  
Hardware Specification  
Network Connector  
RS-232 connector  
Switch architecture  
Switch Fabric  
8-Port RJ-45 for 10/100Base-TX  
One RS-232 DB-9 male connector for switch management  
Store and forward switch architecture.  
Back-plan up to 1.6Gbps  
MAC address  
8K MAC address table with Auto learning function  
512K byte  
Shared Buffer  
Power requirement  
Operating environment  
Storage environment  
Dimension (W x D x H)  
Switch Specification  
Spanning Tree  
90~240V AC, 50/60Hz,  
0~50 degree C, 5%~90%RH  
-20~70 degree C, 5%~90%RH  
280×173×44 mm  
802.1d, 802.1w  
Link Aggregation  
Priority Queue  
4 groups, up to 4 ports per group  
802.1p Class of Service (4 Queues)  
Port Mirror  
RX/TX/Both  
Bandwidth Control  
Strom Control  
Yes, per port per 64kbps, up to 80Mbps  
Per 64kbps, up to 80Mbps  
IGMP Snooping  
MAC Filtering  
v1, v2  
Yes  
VLAN  
Port-Based/ 802.1q, 4K VLAN ID, 256 groups  
Port Analysis  
Yes  
Static Routing Port  
Security  
Yes  
802.1X Port-Based Authentication  
Management Function  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Management Interface  
SNMP Version  
Console/Web/Telnet/SNMP  
v1, v2c  
Support MIB  
Support SNMP MIB(RFC 1213),  
Bridge MIB (RFC 1493),  
RMON group 1,2,3,9  
Enterprise private MIB  
Standard Compliance  
Network Standard  
IEEE802.3 10Base-T  
IEEE802.3u 100Base-TX  
IEEE802.3x Flow Control and Back pressure  
IEEE802.3ad Port trunk with LACP  
IEEE802.1d Spanning tree protocol  
IEEE802.1w Rapid Spanning Tree  
IEEE802.1p Class of service  
IEEE802.1Q VLAN Tagging  
IEEE802.1X Network Access Control  
FCC Class A, CE  
EMI  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. INSTALLATION  
This section describes the functionalities of the Switch's components and guides how to install it on the desktop or  
shelf. Basic knowledge of networking is assumed. Please read this chapter completely before continuing.  
2.1 Product Description  
2.1.1 Product Overview  
With 8-Port 10/100Mbps TP, the PLANET WSD-800 boasts a high performance switch architecture that is capable  
of providing non-blocking switch fabric and wire-speed throughput as high as 1.6Gbps.  
The IEEE 802 standard-based firmware provides a rich set of features and ensures interoperability with equipment  
from other vendors. Additionally, the firmware includes advanced features such as IGMP snooping, broadcast  
storm control, and MAC address filtering, to enhance security and bandwidth utilization.  
With its built-in web-based management, the PLANET WSD-800 offers an easy-to-use, platform-independent  
management and configuration facility. The PLANET WSD-800 supports standard Simple Network Management  
Protocol (SNMP) and can be managed via any standard-based management software. For text-based  
management, the WSD-800 can also be accessed via Telnet and the console port.  
2.1.2 Switch Front Panel  
Figure 2-1 shows the front panel of the switch.  
Figure 2-1 WSD-800 front panel.  
2.1.3 LED Indications  
Network:  
LED  
Color  
Green  
Green  
Orange  
Function  
PWR  
Lights to indicate that the Switch is powered on.  
Lights to indicate the system is working.  
Blink to indicate that the switch is actively sending or receiving data over  
that port.  
SYS  
LNK/ACT  
FDX/COL  
100  
Green  
Green  
Lights to indicate the link through that port is in duplex mode.  
Lights to indicate the port is acting in 100Mbps speed.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2.1.4 Switch Rear Panel  
Figure 2-2 shows the rear panel of the switch  
Figure 2-2 WSD-800 rear panel.  
Power Notice:  
1. The device is a power-required device, it means, it will not work till it is powered. If your networks should  
active all the time, please consider using UPS (Uninterrupted Power Supply) for your device. It will prevent  
you from network data loss or network downtime.  
2. In some area, installing a surge suppression device may also help to protect your switch from being damaged  
by unregulated surge or current to the Switch or the power adapter.  
2.2 Install the Switch  
This section describes how to install the Ethernet Switch and make connections to it. Please read the following  
topics and perform the procedures in the order being presented.  
2.2.1 Desktop Installation  
To install the Switch on desktop or shelf, please follows these steps:  
Step1: Attach the rubber feet to the recessed areas on the bottom of the switch.  
Step2: Place the switch on the desktop or the shelf near an AC power source.  
Step3: Keep enough ventilation space between the switch and the surrounding objects.  
"Note: When choosing a location, please keep in mind the environmental restrictions discussed in Chapter 1,  
Section 4, in Specification.  
Step4: Connect the Switch to network devices.  
A. Connect one end of a standard network cable to the 10/100/1000 RJ-45 ports on the front of the Switch  
B. Connect the other end of the cable to the network devices such as printer servers, workstations or  
routers…etc.  
"Note: Connection to the Switch requires UTP Category 5 network cabling with RJ-45 tips. For more  
information, please see the Cabling Specification in Appendix A.  
Step5: Supply power to the switch.  
A. Connect one end of the power cable to the switch.  
B. Connect the power plug of the power cable to a standard wall outlet.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
When the switch receives power, the Power LED should remain solid Green.  
2.2.2 Rack Mounting  
To install the switch in a 19-inch standard rack, please follows the instructions described below.  
Step1: Place the switch on a hard flat surface, with the front panel positioned towards the front side.  
Step2: Attach the rack-mount bracket to each side of the switch with supplied screws attached to the package.  
Figure 2-5 shows how to attach brackets to one side of the switch.  
Figure 2-5 Attach brackets to the switch.  
Caution:  
You must use the screws supplied with the mounting brackets. Damage caused to the parts by using incorrect  
screws would invalidate the warranty.  
Step3: Secure the brackets tightly.  
Step4: Follow the same steps to attach the second bracket to the opposite side.  
Step5: After the brackets are attached to the Switch, use suitable screws to securely attach the brackets to the  
rack, as shown in Figure 2-6  
Figure 2-6 Mounting the Switch in a Rack  
Step6: Proceeds with the steps 4 and steps 5 of session 2.2.1 Desktop Installation to connect the network cabling  
and supply power to the switch.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3. CONSOLE MANAGEMENT  
3.1 Connecting to the Switch  
The console port is a female DB-9 connector that enables a connection to a PC or terminal for monitoring and  
configuring the Switch. Use the supplied RS-232 cable with a male DB-9 connector to connect a terminal or PC to  
the Console port. The Console configuration (out of band) allows you to set Switch for remote terminal as if the  
console terminal were directly connected to it.  
3.2 Login in the Console Interface  
When the connection between Switch and PC is ready, turn on the PC and run a terminal emulation program or  
Hyper Terminal and configure its communication parameters to match the following default characteristics of the  
console port:  
Baud Rate: 9600 bps  
Data Bits: 8  
Parity: none  
Stop Bit: 1  
Flow control: None  
The settings of communication parameters  
After finished the parameter settings, click “OK“. When the prompt shows “switch>”, type “?” for help or type  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
“enable” for further configuration. The system needs password for further configuration. After the “enable”  
command, the system asks for password, please enter “admin” for the default password. As shows in the  
following screen:  
Console login screen  
3.3 Console Management  
Entering a question mark "?" at the prompt displays the list of commands available for command mode.  
As shows in the following screen:  
The question mark “?” command  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3.4 Telnet login  
The switch also supports telnet for remote management. The switch asks for user name and password for remote  
login when using telnet, please use “admin” for username and “admin” for password.  
3.5 Commands  
There are two levels for console commands. The first level provides commands to show system informations and  
current configurations. The second level (privileged mode) provides commands to set, clear and show the  
configuration.  
3.5.1 First level commands  
The follow table lists the first commands and the equivalent usages.  
Command  
Description  
enable  
Enable privileged mode  
Show channel information  
Show console-info  
show channel  
show console-info  
show dow1x local-userInfo  
show dot1x state  
Show dot1x local user information  
Show dot1x information  
show igmp snooping group-limit  
show igmp-snooping group  
number  
show igmp-snooping group policy  
show igmp-snooping info  
show igmp-snooping policy deny  
show ip http server  
show ip telnet server  
show ipstack info  
Show igmp snooping group policy  
Show igmp snooping information  
Show igmp snooping policy deny  
Show http server information  
Show telnet server information  
Show ip stack information  
show mirror  
Show mirror information  
show multicast router  
show port counter  
show port dot1x  
Show multicast router port information  
Show port counter information  
Show port dot1x information  
show port mac-learning  
show port rate-shaping  
show port rstp-extension  
show port spantree  
Show MACs on certain port  
Show port ingress and egress rate-shaping  
Show port RSTP port role and protocol mode  
Show spantree information on ports  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
show port state  
Show port infomation  
show port storm-limit  
show qos map cos-queue-map  
show qos map dot1p-cos-map  
show qos map mac-cos-map  
show qos map port-cos-map  
show qos map vlan-cos-map  
show qos queue egress-policy  
show radius  
Show port storm limit mode and rate  
Show qos map cos-queue-map  
Show qos map cos-queue-map  
Show qos map mac-cos-map  
Show each port's cos  
Show qos map vlan-cos-map  
Show qos queue egress-policy  
Show radius information  
Show MAC aging time  
show security MAC-aging  
show security filter-MAC  
show security mac-learning  
show security static-MAC  
show snmp  
Show MAC filter entry  
Show port security status  
Show static mac table information  
Show snmp information  
show snmp rmon  
Show snmp rmon state  
show spantree  
Show spanning tree information  
Show basic help infomation  
Show system information  
Show trunk information  
show syntax  
show system  
show trunk  
show version  
Get last software version  
Show vlan information  
show vlan  
show vlan type  
Show current vlan type  
3.5.2 Privileged Command  
To access to the second level, enter the “enable” command in the first level. The sysem then prompt for a  
password. Please enter “password” for the password.  
The promt then changes to “Switch\enable>”. Entering a question mark "?" at the prompt displays the list of  
commands available for command mode.  
3.5.2.1 Clear command  
Clear command is to clear the parameter. The follow table lists the clear commands and the equivalent usages.  
Command  
Description  
clear channel  
Clear member from channel  
Clear igmp-snooping group policy  
Clear igmp snooping policy deny  
Clear egress monitored port for mirror  
clear dot1x local-userInfo  
clear igmp-snooping policy deny  
clear mirror monitored-port egress  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
clear mirror monitored-port ingress  
clear multicast router  
clear port counters  
Clear ingress monitored port for mirror  
Clear router port  
Clear port statistics counter  
clear port rate-shaping  
clear port spantree portcost  
clear port spantree portpri  
clear port storm-limit  
clear qos map cos-queue-map  
clear qos map dot1p-cos-map  
clear qos map mac-cos-map  
clear qos map vlan-cos-map  
clear radius key  
Clear rate-shaping of all ports  
Restore spanning tree port cost to default value  
Restore spanning tree port priority to default value  
Clear strom limit of all ports  
Reset cos-queue map to default  
Reset dot1p_cos map to default  
Clear qos map mac-cos-map  
Clear qos map vlan-cos-map  
Clear radius share key  
clear security filter-MAC  
clear security static-MAC  
clear snmp community  
clear snmp trap  
Clear MAC filter entry  
Clear static MAC entry  
Clear snmp community entry  
Clear snmp trap management host  
Restore spanning tree parameters  
Clear trunk port from vlans  
clear spantree root  
clear trunk  
clear vlan  
Clear member from vlan  
copy config flash  
Copy system configuration parameters to default value  
Clear strom limit of all ports  
clear port storm-limit  
clear qos map cos-queue-map  
clear qos map dot1p-cos-map  
clear qos map mac-cos-map  
clear qos map vlan-cos-map  
clear security filter-MAC  
clear security static-MAC  
clear snmp community  
clear snmp trap  
Reset cos-queue map to default  
Reset dot1p_cos map to default  
Clear qos map mac-cos-map  
Clear qos map vlan-cos-map  
Clear MAC filter entry  
Clear static MAC entry  
Clear snmp community entry  
Clear snmp trap management host  
Restore spanning tree parameters  
Clear trunk port from vlans  
clear spantree root  
clear trunk  
clear vlan  
Clear member from vlan  
3.5.2.2 Copy command  
Once the configuration is changed, it remains the original after a reboot unless the configuration is saved. Copy  
command is to save the current configuration to the flash, this saves the configuration to next reboot.  
Command  
Description  
Download from Www.Somanuals.com. All Manuals Search And Download.  
copy config flash  
Copy system configuration parameters to flash  
3.5.2.3 Disable command  
Disable command is to exit the privileged mode and back to the first level of command line interface.  
Command  
Description  
Disable  
Disable privileged mode  
3.5.2.4 Reboot command  
Reboot command is to reboot the switch, please beware to check if the configuration is saved..  
Command  
Description  
Reboot  
Reboot system  
3.5.2.5 Set command  
Set command is to change the parameter of the switch functions. The follow table lists the set commands and the  
equivalent usages.  
Command  
Description  
set channel  
Set ports to be channel  
set default  
Set system load default parameters  
Set dot1x auth mode  
set dot1x auth mode  
set dot1x auth-ctrl disable  
set dot1x auth-ctrl enable  
set dot1x local-userInfo  
set dot1x max-req  
set dot1x quiet-period  
Disable dot1x  
Enable dot1x  
Set dot1x local user information  
Max times of re-transmit EAP request to Supplicant  
Quiet-period in secondst  
Max times of re-transmit Request/ID before port become  
Unauthorized  
set dot1x reauth-max  
set dot1x reauth-mode  
set dot1x reauth-period  
set dot1x servertimeout  
set dot1x supptimeout  
set dot1x tx-period  
Enable or Disable reauthentication  
Period for automatic re-authentication  
Authentication server timeout  
Timeout for supplicant  
Set dot1x server timeout  
set enable password  
Set the password for the privileged level of the CLI  
Disable igmp snooping  
set igmp-snooping disable  
set igmp-snooping enable  
Enable igmp snooping  
Disable/Enable forward all-leave when fastleave is  
disabled  
set igmp-snooping forward-all-leave  
Download from Www.Somanuals.com. All Manuals Search And Download.  
set igmp-snooping group number  
set igmp-snooping group policy  
set igmp-snooping immediate-leave  
set igmp-snooping policy deny  
set ip http server disable  
set ip http server enable  
set ip telnet server disable  
set ip telnet server enable  
set ipstack enable  
Set number of goups that a port can join in  
Set igmp-snooping group policy  
Disable & Enable igmp snooping immediate-leave  
Set igmp snooping policy deny  
Disable http server  
Enable http server  
Disable telnet server  
Enable telnet server  
Set ipstack enable  
set ipstack disable  
Set ipstack disable  
set ipstack group  
Set ipstack group STR  
set ipstack mac-addr  
Set ipstack mac-addr  
set ipstack mode  
Set ipstack mode master/client  
Set ipstack system-priority  
Enable/Disable mirror function  
Set a port to capture traffic  
Capture egress traffic  
set ipstack system-priority  
set mirror  
set mirror capture-port  
set mirror monitored-port egress  
set mirror monitored-port ingress  
set multicast router  
Capture ingress traffic  
Set multicst router port  
set password  
Set the password for telnet  
Disable a port  
set port disable  
set port duplex  
Set port transmission type  
Enable a port  
set port enable  
set port flow-control  
Set port traffic flowcontrol  
Set port mcheck  
set port mcheck-rstp  
set port point-to-point  
Set port point-to-point admin value  
Set port egress rate-shaping rate  
Set port ingress rate-shaping rate  
Set port egress rate-shaping rate  
Set port ingress rate-shaping rate  
Set spanning tree port cost  
Set spanning tree PortFast feature  
Set spanning tree port priority  
Set port transmission speed  
Set port storm limit mode  
Set port storm limit rate  
set port rate-shaping egress  
set port rate-shaping ingress  
set port rate-shaping egress  
set port rate-shaping ingress  
set port spantree <port_num> portco  
set port spantree <port_num> portfa  
set port spantree <port_num> portpr  
set port speed  
set port storm-limit mode  
set port storm-limit rate  
set port vlan-type  
Set port vlan-type  
Download from Www.Somanuals.com. All Manuals Search And Download.  
set qos map cos-queue-map  
set qos map dot1p-cos-map  
set qos map mac-cos-map  
set qos map port-cos-map  
set qos map vlan-cos-map  
set qos queue egress-policy  
set radius key  
Set the queue number of each cos  
Set the cos value of each dot1p priority  
Set MAC based qos  
Set port's cos  
Set vlan based qos  
Set the egress policy  
Set share key for radius server  
Set radius server parameters  
Set RSTP force version  
set radius server  
set rstp force-version  
set security MAC-aging  
set security filter-MAC  
set security mac-learning  
set security static-MAC  
set snmp  
Set MAC aging time  
Create MAC filter entry  
Set port leanrning MAC (enable|disable)  
Create static MAC entry  
Enable/Disable snmp agent  
Set snmp community string  
Enable/Disable rmon state  
Set snmp trap receive host  
Disable spanning tree  
set snmp community  
set snmp rmon  
set snmp trap  
set spantree disable  
set spantree enable  
set spantree fwddelay  
set spantree hello  
Enable spaning tree  
Set the forward delay for the spanning tree  
Set the hello interval for the spanning tree  
Set the max age interval for the spanning  
Set the bridge priority for the spanning tree  
Set system contact  
set spantree maxage  
set spantree priority  
set system contact  
set system default-gateway  
set system ip  
Set default gateway  
Set system ip mask  
set system location  
set system mac  
Set system location  
Set system mac address  
Specify a vlan for system management  
Set system name  
set system management-vlan  
set system name  
set trunk  
Set vlan trunk port  
set vlan <vid> name  
set vlan <vlan id> <portlist>  
set vlan port-mode  
Set vlan name  
Set vlan members  
Set vlan port-mode  
set vlan type port-based  
set vlan type dot1q-based  
set snmp rmon  
Set system be port-based vlan  
Set system be dot1q-based vlan  
Enable/Disable rmon state  
Download from Www.Somanuals.com. All Manuals Search And Download.  
set snmp trap  
Set snmp trap receive host  
Disable spanning tree  
set spantree disable  
3.5.2.6 Show command  
Show command is to display the current parameter of the switch functions. The follow table lists the show  
commands and the equivalent usages.  
Command  
Description  
show channel  
Show channel information  
Show console-info  
show console-info  
show dot1x local-userInfo  
show dot1x state  
Show dot1x local user information  
Show dot1x information  
show igmp-snooping group number  
show igmp-snooping group policy  
show igmp-snooping info  
show igmp-snooping policy deny  
show igmp-snooping  
show ip http server  
Show igmp-snooping group-limit  
Show igmp-snooping group policy  
Show igmp snooping information  
Show igmp snooping policy deny  
Show igmp snooping information  
Show http server information  
Show telnet server information  
Show ipstack info  
show ip telnet server  
show ipstack info  
show mirror  
Show mirror information  
show multicast router  
show port counter  
Show multicast router port information  
Show port counter information  
Show dot1x information  
show port dot1x  
show port mac-learning  
show port rate-shaping  
show port spantree  
Show MACs on certain port  
Show port ingress and egress rate-shaping  
Show spantree information on ports  
Show port infomation  
show port state  
show port storm-limit  
show qos map cos-queue-map  
show qos map dot1p-cos-map  
show qos map mac-cos-map  
show qos map port-cos-map  
show qos map vlan-cos-map  
show qos queue egress-policy  
show radius  
Show port storm limit mode and rate  
Show qos map cos-queue-map  
Show qos map cos-queue-map  
Show qos map mac-cos-map  
Show each port's cos  
Show qos map vlan-cos-map  
Show qos queue egress-policy  
Show radius information  
show security MAC-aging  
show security filter-MAC  
Show MAC aging time  
Show MAC filter entry  
Download from Www.Somanuals.com. All Manuals Search And Download.  
show security mac-learning  
show security static-MAC  
show snmp  
Show port security status  
Show static mac table information  
Show snmp information  
Show snmp rmon state  
show snmp rmon  
show spantree  
show syntax  
Show spanning tree information  
Show basic help infomation  
Show system information  
Show trunk information  
show system  
show trunk  
show version  
Get last software version  
Show vlan information  
show vlan  
show vlan type  
Show current vlan type  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. WEB-BASED MANAGEMENT  
This section introduces the configuration and functions of the Web-Based management.  
4.1 About Web-based Management  
The switch offers management features that allow users to manage the switch from anywhere on the network  
through a standard browser such as Microsoft Internet Explorer.  
The Web-Based Management supports Internet Explorer 5.0. It is based on Java Applets with an aim to reduce  
network bandwidth consumption, enhance access speed and present an easy viewing screen.  
Note: By default, IE5.0 or later version does not allow Java Applets to open sockets. The user has to explicitly  
modify the browser setting to enable Java Applets to use network ports.  
4.2 Preparing for Web Management  
Before use web management, you can use console to login the Switch checking the default IP of the Switch.  
Please refer to Console Management Chapter for console login. If you need change IP address in first time, you  
can use console mode to modify it. The default value is as below:  
IP Address: 192.168.0.100  
Subnet Mask: 255.255.255.0  
Default Gateway: 192.168.0.254  
User Name: admin  
Password: admin  
4.3 System Login  
1.  
2.  
3.  
4.  
Launch the Internet Explorer.  
Enter the IP address of the switch.  
When the login screen appears, use admin/admin as the default username/password respectively to login.  
The main web page of the Web-based management appears. As shows in the following screen.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
WSD-800 Web Management Interface  
4.4 System  
4.4.1 IP Configuration  
The switch can be managed by the Web/Telnet/SNMP interfaces. Administrators can access the management  
interface via the IP address of the switch. The default IP address of the switch is 192.168.0.100. You can change  
the IP address to be in the same IP segment as your LAN network for convinence.  
To change the IP address, click on the System/IP Address menu button. The IP address configuration screen  
then shows in the main page on the web. Enter the new IP address, Submask and Gateway then click on the OK  
button to change.  
IP Address Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.4.2 SNMP  
4.4.2.1 Theory  
The Simple Network Management Protocol (SNMP) is an application layer protocol that facilitates the exchange of  
management information between network devices. It is part of the Transmission Control Protocol/Internet  
Protocol (TCP/IP) protocol suite. SNMP enables network administrators to manage network performance, find and  
solve network problems, and plan for network growth.  
An SNMP-managed network consists of three key components: Network management stations (NMSs), SNMP  
agents, Management information base (MIB) and network-management protocol:  
Network management stations (NMSs)Sometimes called consoles, these devices execute management  
applications that monitor and control network elements. Physically, NMSs are usually engineering  
workstation-caliber computers with fast CPUs, megapixel color displays, substantial memory, and abundant  
disk space. At least one NMS must be present in each managed environment.  
AgentsAgents are software modules that reside in network elements. They collect and store management  
information such as the number of error packets received by a network element.  
Management information base (MIB)A MIB is a collection of managed objects residing in a virtual  
information store. Collections of related managed objects are defined in specific MIB modules.  
network-management protocolA management protocol is used to convey management information  
between agents and NMSs. SNMP is the Internet community's de facto standard management protocol.  
SNMP Operations  
SNMP itself is a simple request/response protocol. NMSs can send multiple requests without receiving a  
response.  
Get -- Allows the NMS to retrieve an object instance from the agent.  
Set -- Allows the NMS to set values for object instances within an agent.  
Trap -- Used by the agent to asynchronously inform the NMS of some event. The SNMPv2 trap message is  
designed to replace the SNMPv1 trap message.  
SNMP community  
An SNMP community is the group that devices and management stations running SNMP belong to. It helps define  
where information is sent. The community name is used to identify the group. A SNMP device or agent may belong  
to more than one SNMP community. It will not respond to requests from management stations that do not belong  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
to one of its communities. SNMP default communities are:  
Write = private  
Read = public  
4.2.2.2 SNMP Configuration  
To configure SNMP management, click on System/SNMP menu button, and the web main page changes to the  
SNMP Management function, as shows in the following:  
The followings are the description of the sub-table.  
1. SNMP Agent Status Configuration  
This block enables to turn on SNMP Agent.  
Enabled / Disabled: To turn on or turn off the SNMP function on the Switch.  
2. System Options  
This table is to define the system name, system location and the contact person of the switch. These informations  
show in the SNMP software of the management workstation which helps to identify the switch that is looking into.  
There are three fields in the “system options” configuration block:  
System Name: The system name of the switch which would show in the SNMP software.  
System Location: The system location of the switch which would show in the SNMP software.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contact: The contact person of the switch which would show in the SNMP software.  
Fill the fileds and click on the “OK” button to save.  
3. Community Configuration  
Use this table to configure the SNMP community strings and define the policy of the relative string. The community  
string acts like a password to permit access to the agent on the Switch. One or more of the following  
characteristics can be associated with the community string:  
Add Community: enter private or public  
Chooses community strings for the Switch management access: read only or read/write  
Read only: Enables requests accompanied by this string to display MIB-object information.  
Read/Write: Enables requests accompanied by this string to display MIB-object information and to set MIB  
objects.  
Complete the above steps and click on the “Add” button.  
The added string then shows in the Current Communities field.  
z
Current Communities: show the list in input field  
4. Management Station Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A trap manager is a management station (SNMP application) that receives traps (the system alerts generated by  
the switch). If no trap manager is defined, no traps are issued. Create a trap manager by entering the IP address  
of the station and a community string.  
Enter Network management stations IP address: 192.168.0.53 (for example)  
Trap Community: must be the same string as “Add community”  
Then click on “Add” button.  
The “Current Management Stations” field shows the trap list.  
4.4.3 Password  
The Password management menu is to set or change the password of the Web Management Interface.  
Click on System/Password menu button, and the Modify Password table shows in the main web page.  
Enter “old password “, “new password”, “confirm password” Click “OK” to change the password.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.4.4 CONSOLE  
This function shows the connection parameters for the Console Management Interface. Click on the  
System/CONSOLE menu button, and the following table shows in the main page of the web.  
4.4.5 System Upgrade  
This function allows performing firmware update from the web interface.  
Click on the System/System Upgrade menu button, and the following table shows in the main page of the web.  
Click on the “Browse” button of the main page, the system would pop up the file selection menu to choose  
firmware. Select on the firmware, and the Update Status would show the file upload status.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.4.6 Saving Parameters  
It takes effect immediately when you change the parameters of the management function when the switch is  
running. But the parameters would not be saved after reboot the swith. To keep the changed parameters, Click on  
the System/Saving Parameters menu button, and click on the “Save” button on the web main page as show in  
the following.  
4.4.7 Parameters Backup & Recovery  
This function is to backup the running configuration to the workstation and to restore the configuration you had  
saved in the workstation.  
Click on the System/Backup & Recovering menu button, and the following table shows in the web main page.  
To backup the running configuration, click on the “Backup the system’s parameters” link, and a pop up window  
shows to save the configuration of the switch to your workstation.  
To recover a saved configuration, click on the “Browse” button in the Parameters Recovery table. A pop up  
window would direct you to upload the configuration file.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.4.8 Load Default  
This function is to reset the configuration of switch to the factory default. Click on the System/Load Default menu  
button, and the following table shows in the web main page.  
4.4.9 Reboot  
This function is to reboot the system.  
4.5 Port Management  
4.5.1 Port Configuration  
This function is to configure and to view the configured port management status, port negotiation mode and the  
port flow control function.  
Management Status: Display port status: Enable or Disable. Disable is to turn off the port.  
Link Status: “Up” to indicate the port is linked while “Down” to indicate the port is not connectd.  
Speed: Shows the negotiation mode and the running speed on the port.  
Duplex: Displays full-duplex or half-duplex mode.  
Flow Control: Display Flow status of port: Enable or Disable, Disable indicates Flow control is off.  
Auto: Display which mode the port is auto-negotiated  
Config: (configured) Displays the state defined by the user.  
Atual: Displays the negotiation result.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.5.2 Port Statistics  
The Port Statistics page provides a view of the current status of every port on the Switch.  
Pressing the “Reset” button will reset all port counters to zero.  
4.5.3 Port Band Restrict  
The function provides the In-Band and Out-Band connection speed restriction on the ports. The Band of the  
connection speed rangs from 64Kbps to 80000Kbps.  
Ingress Port List/Egress Port List field can be filled in distinct number or a port range. For example, you can fill  
with “1, 3” for port 1 and port 3 and “3-5” for port 3 to port 5.  
Band(64~80000Kbps) field can be filled with any number between 64 and 80000.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.6 Redundancy  
4.6.1 Spanning Tree  
1. Spanning Tree Protocol  
The IEEE 802.1D Spanning Tree Protocol and IEEE 802.1W Rapid Spanning Tree Protocol allow for the blocking  
of links between switches that form loops within the network. When multiple links between switches are detected,  
a primary link is established. Duplicated links are blocked from use and become standby links. The protocol allows  
for the duplicate links to be used in the event of a failure of the primary link. Once the Spanning Tree Protocol is  
configured and enabled, primary links are established and duplicated links are blocked automatically. The  
reactivation of the blocked links (at the time of a primary link failure) is also accomplished automatically without  
operator intervention.  
This automatic network reconfiguration provides maximum uptime to network users. However, the concepts of the  
Spanning Tree Algorithm and protocol are a complicated and complex subject and must be fully researched and  
understood. It is possible to cause serious degradation of the performance of the network if the Spanning Tree is  
incorrectly configured. Please read the following before making any changes from the default values.  
The Switch STP performs the following functions:  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Creates a single spanning tree from any combination of switching or bridging elements.  
Creates multiple spanning trees – from any combination of ports contained within a single switch, in user  
specified groups.  
Automatically reconfigures the spanning tree to compensate for the failure, addition, or removal of any  
element in the tree.  
Reconfigures the spanning tree without operator intervention.  
Bridge Protocol Data Units  
For STP to arrive at a stable network topology, the following information is used:  
The unique switch identifier  
The path cost to the root associated with each switch port  
The por tidentifier  
STP communicates between switches on the network using Bridge Protocol Data Units (BPDUs). Each BPDU  
contains the following information:  
The unique identifier of the switch that the transmitting switch currently believes is the root switch  
The path cost to the root from the transmitting port  
The port identifier of the transmitting port  
The switch sends BPDUs to communicate and construct the spanning-tree topology. All switches connected to the  
LAN on which the packet is transmitted will receive the BPDU. BPDUs are not directly forwarded by the switch, but  
the receiving switch uses the information in the frame to calculate a BPDU, and, if the topology changes, initiates a  
BPDU transmission.  
The communication between switches via BPDUs results in the following:  
One switch is elected as the root switch  
The shortest distance to the root switch is calculated for each switch  
A designated switch is selected. This is the switch closest to the root switch through which packets will be  
forwarded to the root.  
A port for each switch is selected. This is the port providing the best path from the switch to the root switch.  
Ports included in the STP are selected.  
Creating a Stable STP Topology  
It is to make the root port a fastest link. If all switches have STP enabled with default settings, the switch with the  
lowest MAC address in the network will become the root switch. By increasing the priority (lowering the priority  
number) of the best switch, STP can be forced to select the best switch as the root switch.  
When STP is enabled using the default parameters, the path between source and destination stations in a  
switched network might not be ideal. For instance, connecting higher-speed links to a port that has a higher  
number than the current root port can cause a root-port change.  
STP Port States  
The BPDUs take some time to pass through a network. This propagation delay can result in topology changes  
where a port that transitioned directly from a Blocking state to a Forwarding state could create temporary data  
Download from Www.Somanuals.com. All Manuals Search And Download.  
loops. Ports must wait for new network topology information to propagate throughout the network before starting to  
forward packets. They must also wait for the packet lifetime to expire for BPDU packets that were forwarded based  
on the old topology. The forward delay timer is used to allow the network topology to stabilize after a topology  
change. In addition, STP specifies a series of states a port must transition through to further ensure that a stable  
network topology is created after a topology change.  
Each port on a switch using STP exists is in one of the following five states:  
Blocking – the port is blocked from forwarding or receiving packets  
Listening – the port is waiting to receive BPDU packets that may tell the port to go back to the blocking  
state  
Learning – the port is adding addresses to its forwarding database, but not yet forwarding packets  
Forwarding – the port is forwarding packets  
Disabled – the port only responds to network management messages and must return to the blocking state  
first  
A port transitions from one state to another as follows:  
From initialization (switch boot) to blocking  
From blocking to listening or to disabled  
From listening to learning or to disabled  
From learning to forwarding or to disabled  
From forwarding to disabled  
From disabled to blocking  
Switch  
Blocking  
Listening  
Learning  
Forwarding  
Disable  
STP Port State Transitions  
You can modify each port state by using management software. When you enable STP, every port on every switch  
in the network goes through the blocking state and then transitions through the states of listening and learning at  
Download from Www.Somanuals.com. All Manuals Search And Download.  
power up. If properly configured, each port stabilizes to the forwarding or blocking state. No packets (except  
BPDUs) are forwarded from, or received by, STP enabled ports until the forwarding state is enabled for that port.  
2. STP Parameters  
STP Operation Levels  
The Switch allows for two levels of operation: the switch level and the port level. The switch level forms a spanning  
tree consisting of links between one or more switches. The port level constructs a spanning tree consisting of  
groups of one or more ports. The STP operates in much the same way for both levels.  
The following are the user-configurable STP parameters for the switch level:  
Parameter  
Description  
Default Value  
Bridge Identifier(Not user  
configurable  
A combination of the User-set priority and  
the switch’s MAC address.  
32768 + MAC  
except by setting priority  
below)  
The Bridge Identifier consists of two parts:  
a 16-bit priority and a 48-bit Ethernet MAC  
address 32768 + MAC  
Priority  
A relative priority for each switch – lower  
numbers give a higher priority and a greater  
chance of a given switch being elected as  
the root bridge  
32768  
Hello Time  
The length of time between broadcasts of  
the hello message by the switch  
Measures the age of a received BPDU for a  
port and ensures that the BPDU is discarded  
when its age exceeds the value of the  
maximum age timer.  
2 seconds  
Maximum Age Timer  
20 seconds  
Forward Delay Timer  
The amount time spent by a port in the  
learning and listening states waiting for a  
BPDU that may return the port to the  
blocking state.  
15 seconds  
The following are the user-configurable STP parameters for the port or port group level:  
Variable Description Default Value  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Port Priority  
Port Cost  
A relative priority for each  
32768  
port –lower numbers give a higher priority  
and a greater chance of a given port being  
elected as the root port  
A value used by STP to evaluate paths –  
STP calculates path costs and selects the  
path with the minimum cost as the active  
path  
19-100Mbps Fast Ethernet ports  
4-1000Mbps Gigabit Ethernet ports  
Default Spanning-Tree Configuration  
Feature  
Default Value  
Enable state  
Port priority  
Port cost  
STP enabled for all ports  
128  
19  
Bridge Priority  
32,768  
User-Changeable STA Parameters  
The Switch’s factory default setting should cover the majority of installations. However, it is advisable to keep the  
default settings as set at the factory; unless, it is absolutely necessary. The user changeable parameters in the  
Switch are as follows:  
Priority – A Priority for the switch can be set from 0 to 65535. 0 is equal to the highest Priority.  
Hello Time – The Hello Time can be from 1 to 10 seconds. This is the interval between two transmissions of  
BPDU packets sent by the Root Bridge to tell all other Switches that it is indeed the Root Bridge. If you set a Hello  
Time for your Switch, and it is not the Root Bridge, the set Hello Time will be used if and when your Switch  
becomes the Root Bridge.  
Max. Age – The Max Age can be from 6 to 40 seconds. At the end of the Max Age, if a BPDU has still not been  
received from the Root Bridge, your Switch will start sending its own BPDU to all other Switches for permission to  
become the Root Bridge. If it turns out that your Switch has the lowest Bridge Identifier, it will become the Root  
Bridge.  
Forward Delay Timer – The Forward Delay can be from 4 to 30 seconds. This is the time any port on the  
Switch spends in the listening state while moving from the blocking state to the forwarding state.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Port Priority – A Port Priority can be from 0 to 255. The lower the number, the greater the probability the port will  
be chosen as the Root Port.  
Port Cost – A Port Cost can be set from 0 to 65535. The lower the number, the greater the probability the port will  
be chosen to forward packets.  
3. Illustration of STP  
A simple illustration of three switches connected in a loop is depicted in Figure 5-7. In this example, you can  
anticipate some major network problems if the STP assistance is not applied. If switch A broadcasts a packet to  
switch B, switch B will broadcast it to switch C, and switch C will broadcast it to back to switch A ... and so on. The  
broadcast packet will be passed indefinitely in a loop, potentially causing a network failure. In this example, STP  
breaks the loop by blocking the connection between switch B and C. The decision to block a particular connection  
is based on the STP calculation of the most current Bridge and Port settings. Now, if switch A broadcasts a packet  
to switch C, then switch C will drop the packet at port 2 and the broadcast will end there. Setting-up STP using  
values other than the defaults, can be complex. Therefore, you are advised to keep the default factory settings and  
STP will automatically assign root bridges/ports and block loop connections. Influencing STP to choose a  
particular switch as the root bridge using the Priority setting, or influencing STP to choose a particular port to block  
using the Port Priority and Port Cost settings is, however, relatively straight forward.  
LAN 1  
Portcast = 19  
Port 3  
A
Bridge ID = 15  
Port 2  
Port 1  
Portcast = 4  
Portcast = 4  
Portcast = 4  
Portcast = 4  
Port 1  
Port 1  
B
C
Bridge ID = 30  
Bridge ID = 20  
Port 3  
Port 3  
Port 2  
Port 2  
Portcast = 19  
Portcast = 19  
LAN 2  
Portcast = 19  
LAN 3  
Before Applying the STA Rules  
In this example, only the default STP values are used.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LAN 1  
Port 3  
A
Root Bridge  
Port 2  
Port 1  
Designated Port  
Designated Port  
Root Port  
Root Port  
Port 1  
Port 1  
B
C
Designated Bridge  
Blocked  
Port 3  
Port 3  
Port 2  
Port 2  
LAN 2  
LAN 3  
After Applying the STA Rules  
The switch with the lowest Bridge ID (switch C) was elected the root bridge, and the ports were selected to give a  
high port cost between switches B and C. The two (optional) Gigabit ports (default port cost = 4) on switch A are  
connected to one (optional) Gigabit port on both switch B and C. The redundant link between switch B and C is  
deliberately chosen as a 100 Mbps Fast Ethernet link (default port cost = 19). Gigabit ports could be used, but the  
port cost should be increased from the default to ensure that the link between switch B and switch C is the blocked  
link.  
4.6.2 Spanning Tree Configuration  
The Spanning Tree Protocol (STP) operates on two levels: On the switch level, the settings are globally  
implemented. On the port level, the settings are implemented on a. per user-defined Group of ports.  
1. Spanning Tree Configuration  
The “Rapid Spanning Tree Bridge Configure” table allows configuring the spanning tree parameters.  
Rapid Spanning Tree Status: The spanning tree function of the switch is default disabled. This field enables to  
turn on the spanning tree on the switch.  
Force Protocol Version: 0 for IEEE 802.1D Spanning Tree, 2 for IEEE 802.1W Rapid Spanning Tree  
Max Age: (6 - 40 sec) the default setting is 20  
Hello Time: (1 - 10sec) the default setting is 2  
Forward Delay: (4 -30 sec) the default setting is 15  
Bridge Priority: (0 - 61440) the default setting is 32768  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2. Bridge Information  
The informations of the STP Root show in the Bridge Information table.  
3. STP Port Configuration  
On the STP port configuration, the settings are implemented on a. per user-defined Group of ports.  
The following fields can be set for STP port configuration:  
Edge Port: Defines if this port connected directly to a single workstation, or this port that is directly connected to a  
LAN segment where a loop cannot be created. For example, this port is connected to a PC, Print-Server, IP  
camera or any other network end-node device. Since end nodes cannot cause forwarding loops, they can pass  
directly through to the spanning tree forwarding state.  
There are two selections for this function:  
True - This port connected directly to a end-node device or LAN segment where a loop cannot be  
created  
False – This port connected to one or more LAN segments – maybe a ethernet switch or HUB, that a  
loop might be occured  
P2P Status: Enables or disables the device to establish a point-to-point link, or specifies for the device to  
automatically establish a point-to-point link. A P2P port is also capable of rapid transition. P2P ports may be used  
Download from Www.Somanuals.com. All Manuals Search And Download.  
to connect to other bridges. Under RSTP, all ports operating in full-duplex mode are considered to be P2P ports,  
unless manually overridden through configuration.  
The link type attached to this port could be selected as following:  
Auto - The switch automatically determines if the interface is attached to a point-to-point link or to shared  
media  
True – A connection to exactly one other bridge.  
False - A connection to two or more bridges.  
Port Priority: Defines if this port is more or less likely to become the root port. The range is from 0 to 255, the  
default setting is 128.The lower number has the highest priority.  
Path Cost: Specifies the path cost of the port. The switch uses this parameter to help determine which port will  
become a forwarding port. Lower numbers will be used as forwarding ports first. The range is from 0 to 65535. The  
default values based on IEEE802.1D are: 10Mb/s = 50-600, 100Mb/s = 10-60, 1000Mb/s = 3-10  
4.6.3 Link Aggregation  
The Link Aggregation Control Protocol (LACP) provides a standardized means for exchanging information  
between Partner Systems that require high speed redundant links. Link aggregation lets you group up to eight  
consecutive ports into a single dedicated connection. This feature can expand bandwidth to a device on the  
network. LACP operation requires full-duplex mode, more detail information refer to the IEEE 802.3ad standard.  
Link aggregation can be used to increase the bandwidth of a network connection or to ensure fault recovery. Link  
aggregation lets you group up consecutive ports into a single dedicated connection between any two of the  
Switches or other Layer 2 switches. However, before making any physical connections between devices, use the  
Link Aggregation menu to specify the link aggregation on the devices at both ends. When using a port link  
aggregation, note that:  
The ports used in a link aggregation must all be of the same media type (RJ-45, 100 Mbps fiber).  
The ports that can be assigned to the same link aggregation have certain other restrictions (see below).  
Ports can only be assigned to one link aggregation.  
The ports at both ends of a connection must be configured as link aggregation ports.  
None of the ports in a link aggregation can be configured as a mirror source port or a mirror target port.  
All of the ports in a link aggregation have to be treated as a whole when moved from/to, added or deleted  
from a VLAN.  
The Spanning Tree Protocol will treat all the ports in a link aggregation as a whole.  
Enable the link aggregation prior to connecting any cable between the switches to avoid creating a data  
loop.  
Disconnect all link aggregation port cables or disable the link aggregation ports before removing a port link  
aggregation to avoid creating a data loop.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
It allows a maximum of four ports to be aggregated at the same time and up to 4 groups. If the group is defined as  
a LACP static link aggregationing group, then any extra ports selected are placed in a standby mode for  
redundancy if one of the other ports fails. If the group is defined as a local static link aggregationing group, then  
the number of ports must be the same as the group member ports.  
4.7 Security  
4.7.1 VLAN  
4.7.1.1 Theory  
Understanding IEEE 802.1p Priority  
Priority tagging is a function defined by the IEEE 802.1p standard designed to provide a means of managing traffic  
on a network where many different types of data may be transmitted simultaneously. It is intended to alleviate  
problems associated with the delivery of time critical data over congested networks. The quality of applications  
that are dependent on such time critical data, such as video conferencing, can be severely and adversely affected  
by even very small delays in transmission.  
Network devices that are in compliance with the IEEE 802.1p standard have the ability to recognize the priority  
level of data packets. These devices can also assign a priority label or tag to packets. Compliant devices can also  
strip priority tags from packets. This priority tag determines the packet's degree of expeditiousness and  
determines the queue to which it will be assigned.  
Priority tags are given values from 0 to 7 with 0 being assigned to the lowest priority data and 7 assigned to the  
highest. The highest priority tag 7 is generally only used for data associated with video or audio applications,  
which are sensitive to even slight delays, or for data from specified end users whose data transmissions warrant  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
special consideration.  
The Switch allows you to further tailor how priority tagged data packets are handled on your network. Using  
queues to manage priority tagged data allows you to specify its relative priority to suit the needs of your network.  
There may be circumstances where it would be advantageous to group two or more differently tagged packets into  
the same queue. Generally, however, it is recommended that the highest priority queue, Queue 1, be reserved for  
data packets with a priority value of 7. Packets that have not been given any priority value are placed in Queue 0  
and thus given the lowest priority for delivery.  
A weighted round robin system is employed on the Switch to determine the rate at which the queues are emptied  
of packets. The ratio used for clearing the queues is 4:1. This means that the highest priority queue, Queue 1, will  
clear 4 packets for every 1 packet cleared from Queue 0.  
Remember, the priority queue settings on the Switch are for all ports, and all devices connected to the Switch will  
be affected. This priority queuing system will be especially beneficial if your network employs switches with the  
capability of assigning priority tags.  
VLAN Description  
A Virtual Local Area Network (VLAN) is a network topology configured according to a logical scheme rather than  
the physical layout. VLAN can be used to combine any collection of LAN segments into an autonomous user  
group that appears as a single LAN. VLAN also logically segment the network into different broadcast domains so  
that packets are forwarded only between ports within the VLAN. Typically, a VLAN corresponds to a particular  
subnet, although not necessarily.  
VLAN can enhance performance by conserving bandwidth, and improve security by limiting traffic to specific  
domains.  
A VLAN is a collection of end nodes grouped by logic instead of physical location. End nodes that frequently  
communicate with each other are assigned to the same VLAN, regardless of where they are physically on the  
network. Logically, a VLAN can be equated to a broadcast domain, because broadcast packets are forwarded to  
only members of the VLAN on which the broadcast was initiated.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Port-based VLAN  
Port-based VLAN limit traffic that flows into and out of switch ports. Thus, all devices connected to a port are  
members of the VLAN(s) the port belongs to, whether there is a single computer directly connected to a switch, or  
an entire department.  
On port-based VLAN.NIC do not need to be able to identify 802.1Q tags in packet headers. NIC send and receive  
normal Ethernet packets. If the packet's destination lies on the same segment, communications take place using  
normal Ethernet protocols. Even though this is always the case, when the destination for a packet lies on another  
switch port, VLAN considerations come into play to decide if the packet is dropped by the Switch or delivered.  
IEEE 802.1Q VLANs  
IEEE 802.1Q (tagged) VLAN are implemented on the Switch. 802.1Q VLAN require tagging, which enables them  
to span the entire network (assuming all switches on the network are IEEE 802.1Q-compliant).  
VLAN allow a network to be segmented in order to reduce the size of broadcast domains. All packets entering a  
VLAN will only be forwarded to the stations (over IEEE 802.1Q enabled switches) that are members of that VLAN,  
and this includes broadcast, multicast and unicast packets from unknown sources.  
VLAN can also provide a level of security to your network. IEEE 802.1Q VLAN will only deliver packets between  
stations that are members of the VLAN. Any port can be configured as either tagging or untagging. The untagging  
feature of IEEE 802.1Q VLAN allows VLAN to work with legacy switches that don't recognize VLAN tags in packet  
headers. The tagging feature allows VLAN to span multiple 802.1Q-compliant switches through a single physical  
connection and allows Spanning Tree to be enabled on all ports and work normally.  
Any port can be configured as either tagging or untagging. The untagging feature of IEEE 802.1Q VLAN allow  
VLAN to work with legacy switches that don’t recognize VLAN tags in packet headers. The tagging feature allows  
VLAN to span multiple 802.1Q-compliant switches through a single physical connection and allows Spanning Tree  
to be enabled on all ports and work normally.  
Some relevant terms:  
Tagging - The act of putting 802.1Q VLAN information into the header of a packet.  
Untagging - The act of stripping 802.1Q VLAN information out of the packet header.  
802.1Q VLAN Tags  
The figure below shows the 802.1Q VLAN tag. There are four additional octets inserted after the source MAC  
address. Their presence is indicated by a value of 0x8100 in the Ether Type field. When a packet's Ether Type field  
is equal to 0x8100, the packet carries the IEEE 802.1Q/802.1p tag. The tag is contained in the following two octets  
and consists of 3 bits of user priority, 1 bit of Canonical Format Identifier (CFI - used for encapsulating Token Ring  
packets so they can be carried across Ethernet backbones), and 12 bits of VLAN ID (VID). The 3 bits of user  
Download from Www.Somanuals.com. All Manuals Search And Download.  
priority are used by 802.1p. The VID is the VLAN identifier and is used by the 802.1Q standard. Because the VID  
is 12 bits long, 4094 unique VLAN can be identified.  
The tag is inserted into the packet header making the entire packet longer by 4 octets. All of the information  
originally contained in the packet is retained.  
802.1Q Tag  
User Priority  
3 bits  
CFI  
VLAN ID (VID)  
12 bits  
1 bits  
TPID (Tag Protocol Identifier)  
2 bytes  
TCI (Tag Control Information)  
2 bytes  
Preamble  
Destination  
Address  
6 bytes  
Source  
Address  
6 bytes  
VLAN TAG  
Ethernet  
Type  
Data  
FCS  
4 bytes  
2 bytes  
46-1517 bytes  
4 bytes  
The Ether Type and VLAN ID are inserted after the MAC source address, but before the original Ether  
Type/Length or Logical Link Control. Because the packet is now a bit longer than it was originally, the Cyclic  
Redundancy Check (CRC) must be recalculated.  
Adding an IEEE802.1Q Tag  
Original Ethernet  
Dest. Addr.  
Dest. Addr.  
Src. Addr.  
Src. Addr.  
Length/E. type  
Data  
Old CRC  
E. type  
Tag  
Length/E. type  
Data New CRC  
New Tagged Packet  
Priority  
CFI  
VLAN ID  
Port VLAN ID  
Packets that are tagged (are carrying the 802.1Q VID information) can be transmitted from one 802.1Q compliant  
network device to another with the VLAN information intact. This allows 802.1Q VLAN to span network devices  
(and indeed, the entire network – if all network devices are 802.1Q compliant).  
Every physical port on a switch has a PVID. 802.1Q ports are also assigned a PVID, for use within the switch. If no  
VLAN are defined on the switch, all ports are then assigned to a default VLAN with a PVID equal to 1. Untagged  
packets are assigned the PVID of the port on which they were received. Forwarding decisions are based upon this  
PVID, in so far as VLAN are concerned. Tagged packets are forwarded according to the VID contained within the  
tag. Tagged packets are also assigned a PVID, but the PVID is not used to make packet forwarding decisions, the  
VID is.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Tag-aware switches must keep a table to relate PVID within the switch to VID on the network. The switch will  
compare the VID of a packet to be transmitted to the VID of the port that is to transmit the packet. If the two VID  
are different the switch will drop the packet. Because of the existence of the PVID for untagged packets and the  
VID for tagged packets, tag-aware and tag-unaware network devices can coexist on the same network.  
A switch port can have only one PVID, but can have as many VID as the switch has memory in its VLAN table to  
store them.  
Because some devices on a network may be tag-unaware, a decision must be made at each port on a tag-aware  
device before packets are transmitted – should the packet to be transmitted have a tag or not? If the transmitting  
port is connected to a tag-unaware device, the packet should be untagged. If the transmitting port is connected to  
a tag-aware device, the packet should be tagged.  
Default VLANs  
The Switch initially configures one VLAN, VID = 1, called "default." The factory default setting assigns all ports on  
the Switch to the "default". As new VLAN are configured in Port-based mode, their respective member ports are  
removed from the "default."  
VLAN and Trunk Groups  
In order to use VLAN segmentation in conjunction with port trunk groups, you can first set the port trunk group(s),  
and then you may configure VLAN settings. If you wish to change the port trunk grouping with VLAN already in  
place, you will not need to reconfigure the VLAN settings after changing the port trunk group settings. VLAN  
settings will automatically change in conjunction with the change of the port trunk group settings  
4.7.1.2 VLAN Configuration  
Port-based VLAN Configuration  
Packets can only be broadcast among other members of the same VLAN group. Note all unselected ports are  
treated as belonging to the default system VLAN. If port-based VLAN are enabled, then VLAN-tagging is ignored.  
1. On VLAN Configuration table, choose Port-based VLAN. Click on the “OK” button.  
2. The main page then change to Port-base VLAN table, click on the “Add/Modify” button to create a new VLAN  
group.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. The Port-base VLAN Confirutation table then pops up, enter the VLAN group ID, VLAN name and select the  
member ports for the VLAN.  
4. Click the “OK” button to add the VLAN.  
5. Select the ports in the Port List field and click on the Add button to add the member ports to the VLAN. The  
selected VLAN member then shows in the VLAN Member field.  
6. Click on the “Close” button and back to the Port-based VLAN main page.  
The “Show VLAN Member” button is to list the valid VLANs. You can also remove the added VALN by click on  
this button.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
802.1Q VLAN Configuration  
There are up to 256 configurable VLAN groups. By default when 802.1Q is enabled, all ports on the switch belong  
to default VLAN (VID 1). The default VLAN cannot be deleted.  
Understand nomenclature of the Switch  
Tagging and Untagging  
Every port on an 802.1Q compliant switch can be configured as tagging or untagging.  
Tagging: Ports with tagging enabled will put the VID number, priority and other VLAN information into the  
header of all packets that flow into those ports. If a packet has previously been tagged, the port will not alter  
the packet, thus keeping the VLAN information intact. The VLAN information in the tag can then be used by  
other 802.1Q compliant devices on the network to make packet-forwarding decisions.  
Untagging: Ports with untagging enabled will strip the 802.1Q tag from all packets that flow into those ports.  
If the packet doesn't have an 802.1Q VLAN tag, the port will not alter the packet. Thus, all packets received  
by and forwarded by an untagging port will have no 802.1Q VLAN information. (Remember that the PVID is  
only used internally within the Switch). Untagging is used to send packets from an 802.1Q-compliant  
network device to a non-compliant network device.  
Frame Income  
Income Frame is tagged  
Income Frame is untagged  
Frame Leave  
Leave port is tagged  
Frame remains tagged  
Tag is removed  
Tag is inserted  
Leave port is untagged  
Frame remain untagged  
Here pay attention to the explainion of “Access”, ”Always Untag”and “Trunk”.  
Access: Ports will strip the 802.1Q tag from all packets that out of those ports. If the packet doesn’t have an  
802.1Q VLAN tag, the port will not alter the packet. Thus, all packets received by and forwarded by an  
untagging port will have no 802.1Q VLAN information. Untagging is used to send packets from an  
802.1Q-compliant network device to a non-compliant network device.  
Ports with “Access” mode belong to a single untagged VLAN.  
Trunk: Ports with tagging enabled will put the VID number, priority and other VLAN information into the  
header of all packets that out of those ports. If a packet has previously been tagged, the port will not alter the  
packet, thus keeping the VLAN information intact. The VLAN information in the tag can then be used by  
other 802.1Q compliant devices on the network to make packet forwarding decisions.  
Always Untag: The port belongs to VLANs, and each VLAN is user-defined as tagged or untagged (full  
802.1Q mode). Ports will strip the 802.1Q tag from all packets that out of those ports.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Port Mode  
Access  
VLAN Membership  
Frame Leave  
Untagged  
( Tag=PVID be removed)  
Untagged  
Belongs to a single untagged VLAN  
Allowed to belongs to multiple untagged  
VLANs at the same time  
Always Untag  
Trunk  
(Tag=PVID be removed)  
Tagged  
Allowed to belongs to multiple Tagged  
VLANs at the same time  
(Tag=PVID or Original VID be remained)  
Port VID (PVID)  
Set the port VLAN ID that will be assigned to untagged traffic on a given port. This feature is useful for  
accommodating devices that you want to participate in the VLAN but that don’t support tagging. The Switch allows  
each port to set one PVID, the range is 1~255, default PVID is 1. The PVID must be the same as the VLAN ID that  
the port was defined as belonging to in the VLAN group, or the untagged traffic will be dropped.  
1. Select 802.1Q VLAN in the VLAN Type field and click on the “OK” button.  
The main page then changes to the 802.1Q VLAN table which displays the VLAN configuration of each port.  
2. If you want to configure port #2 to be in a VLAN other than default VLAN. Double click on “port2” to enter into  
VLAN port configuration window.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Choose the Link Type in the drop drop down menu: Access , Always Untag or Trunk.  
Note that if the Access type is chosen, it will strip the 802.1Q tag from all packets that out of this port. On the other  
hand, if the Trunk type is chosen, it will put the VID number, priority and other VLAN information into the header of  
all packets that out of this port. And if the Always Untag type is chosen, it will strip the 802.1Q tag from all packets  
that out of the port. But the port can be assigned to more than one VLAN group.  
4. Define the PVID for the port  
Set the port VLAN ID that will be assigned to untagged traffic on a given port. This feature is useful for  
accommodating devices that you want to participate in the VLAN but that don’t support tagging.  
5. Trunk configuration: If the Trunk type is chosen, please follow the steps to set the Trunk of the port.  
5.1 Add and define the names and VIDs for new VLANs. The VID number ranges from 2 to 4094. Fill the VID field  
and the VLAN Name field in the Set VLAN’s VID & Name table and click on the “Add/Modify” button to save.  
5.2 The added new VLAN then shows the the VLAN Table field in the Set Trunk Port for VLAN table.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5.3 Select on the VLAN chich you want to tag with in the VLAN Table field and click on the “Add” button to add.  
This will add the VLAN in to the VLAN with The Trunk Port field.  
5.4 Click on the “close” button to close the VLAN port configuration table of port #2, and back to the 802.1Q main  
page.  
5.5 Click on the “Show VLAN Members” button to show the VLAN members.  
5.6 As shows in the following screen:  
4.7.2 MAC Address Bind  
This function is based upon for the switch security. When you add one MAC Address is bind with one port. It  
remains in the switch's address table, regardless of whether the device is physically connected to the switch. This  
saves the switch from having to re-learn a device's MAC address after it has been disconnected or powered-off  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
from the network, and then reconnected at some time later. If the Network station is connected with one port want  
to control the switch, the station’s MAC Address must be the same as one MAC Address  
To bind the MAC Address, click on the Security/MAC Address Binding menu button, the main web page then  
shows the MAC Address Bind function table.  
1. Fill the MAC Address field with MAC address in the format “xx-xx-xx-xx-xx-xx “ and choose the port to bind  
the MAC Address in the Port field.  
2. Click on the “Add” button.  
3. To remove the MAC Address binded by the port. Simply click on the “Delete” button of the MAC Address in the  
Show MAC Address Table.  
4.7.3 MAC Address Filtering  
MAC address filtering allows the switch to drop unwanted traffic. Traffic is filtered based on the destination  
addresses.  
To filter the MAC Address, click on the Security/MAC Address Filtering menu button, the main web page then  
shows the MAC Address Filtering function table.  
1. Fill the MAC Address field with MAC address in the format “xx-xx-xx-xx-xx-xx “.  
2. Click on the “Add” button to add.  
3. To remove the MAC Address filtered by the port. Simply click on the “Delete” button of the MAC Address in the  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Current Filtering MAC Table.  
4.7.4 MAC Address Learning  
The switch is able to disable MAC Address learning function on ports.  
1. Fill the Port List field in the MAC Address Learning table and select Enable/Disable in the MAC Address  
Learning field.  
2. Click on the “OK” button to save.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.7.5 MAC Address Aging Time  
The Aging Time affects the learning process of the Switch. Dynamic forwarding table entries, which are made up  
of the source and destination MAC addresses and their associated port numbers, are deleted from the table if they  
are not accessed within the aging time.  
The aging time can be from 30 to 1,000,000 seconds with a default value of 300 seconds. A very long aging time  
can result in dynamic forwarding table entries that are out-of-date or no longer exist. This may cause incorrect  
packet forward indecisions by the Switch.  
If the Aging Time is too short however, many entries may be aged out too soon. This will result in a high  
percentage of received packets whose source addresses cannot be found in the forwarding table, in which case  
the switch will broadcast the packet to all ports, negating many of the benefits of having a switch.  
Static forwarding entries are not affected by the aging time.  
To set the Aging Time, enter the number in the MAC Address Aging Time field, and click on the “OK” button to  
save. The valid range is 30~1000 seconds. Default is 300 seconds.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.7.6 802.1X Port-Based Network Access Control  
4.7.6.1 Theory  
Understanding IEEE 802.1X Port-Based Authentication  
The IEEE 802.1X standard defines a client-server-based access control and authentication protocol that restricts  
unauthorized clients from connecting to a LAN through publicly accessible ports. The authentication server  
authenticates each client connected to a switch port before making available any services offered by the switch or  
the LAN.  
Until the client is authenticated, 802.1X access control allows only Extensible Authentication Protocol over LAN  
(EAPOL) traffic through the port to which the client is connected. After authentication is successful, normal traffic  
can pass through the port.  
This section includes this conceptual information:  
Device Roles  
With 802.1X port-based authentication, the devices in the network have specific roles as shown below.  
z
Client—the device (workstation) that requests access to the LAN and switch services and responds to  
requests from the switch. The workstation must be running 802.1X-compliant client software such as that  
offered in the Microsoft Windows XP operating system. (The client is the supplicant in the IEEE 802.1X  
specification.)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
z
Authentication server—performs the actual authentication of the client. The authentication server  
validates the identity of the client and notifies the switch whether or not the client is authorized to access  
the LAN and switch services. Because the switch acts as the proxy, the authentication service is  
transparent to the client. In this release, the Remote Authentication Dial-In User Service (RADIUS)  
security system with Extensible Authentication Protocol (EAP) extensions is the only supported  
authentication server; it is available in Cisco Secure Access Control Server version 3.0. RADIUS operates  
in a client/server model in which secure authentication information is exchanged between the RADIUS  
server and one or more RADIUS clients.  
z
Switch (802.1X device)—controls the physical access to the network based on the authentication status  
of the client. The switch acts as an intermediary (proxy) between the client and the authentication server,  
requesting identity information from the client, verifying that information with the authentication server, and  
relaying a response to the client. The switch includes the RADIUS client, which is responsible for  
encapsulating and decapsulating the Extensible Authentication Protocol (EAP) frames and interacting  
with the authentication server. When the switch receives EAPOL frames and relays them to the  
authentication server, the Ethernet header is stripped and the remaining EAP frame is re-encapsulated in  
the RADIUS format. The EAP frames are not modified or examined during encapsulation, and the  
authentication server must support EAP within the native frame format. When the switch receives frames  
from the authentication server, the server's frame header is removed, leaving the EAP frame, which is  
then encapsulated for Ethernet and sent to the client.  
Authentication Initiation and Message Exchange  
The switch or the client can initiate authentication. If you enable authentication on a port by using the dot1x  
port-control auto interface configuration command, the switch must initiate authentication when it determines  
that the port link state transitions from down to up. It then sends an EAP-request/identity frame to the client to  
request its identity (typically, the switch sends an initial identity/request frame followed by one or more requests for  
authentication information). Upon receipt of the frame, the client responds with an EAP-response/identity frame.  
However, if during bootup, the client does not receive an EAP-request/identity frame from the switch, the client  
can initiate authentication by sending an EAPOL-start frame, which prompts the switch to request the client's  
identity  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
When the client supplies its identity, the switch begins its role as the intermediary, passing EAP frames between  
the client and the authentication server until authentication succeeds or fails. If the authentication succeeds, the  
switch port becomes authorized. For more information, see the "Ports in Authorized and Unauthorized States"  
section  
The specific exchange of EAP frames depends on the authentication method being used. “Figure 2-43” shows a  
message exchange initiated by the client using the One-Time-Password (OTP) authentication method with a  
RADIUS server.  
Ports in Authorized and Unauthorized States  
The switch port state determines whether or not the client is granted access to the network. The port starts in the  
unauthorized state. While in this state, the port disallows all ingress and egress traffic except for 802.1X protocol  
packets. When a client is successfully authenticated, the port transitions to the authorized state, allowing all traffic  
for the client to flow normally.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
If a client that does not support 802.1X is connected to an unauthorized 802.1X port, the switch requests the  
client's identity. In this situation, the client does not respond to the request, the port remains in the unauthorized  
state, and the client is not granted access to the network.  
In contrast, when an 802.1X-enabled client connects to a port that is not running the 802.1X protocol, the client  
initiates the authentication process by sending the EAPOL-start frame. When no response is received, the client  
sends the request for a fixed number of times. Because no response is received, the client begins sending frames  
as if the port is in the authorized state  
If the client is successfully authenticated (receives an Accept frame from the authentication server), the port state  
changes to authorized, and all frames from the authenticated client are allowed through the port. If the  
authentication fails, the port remains in the unauthorized state, but authentication can be retried. If the  
authentication server cannot be reached, the switch can retransmit the request. If no response is received from  
the server after the specified number of attempts, authentication fails, and network access is not granted.  
When a client logs off, it sends an EAPOL-logoff message, causing the switch port to transition to the  
unauthorized state.  
If the link state of a port transitions from up to down, or if an EAPOL-logoff frame is received, the port returns to the  
unauthorized state.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.7.6.2 802.1X Configuration  
This switch has two 802.1X Mode: Radius Server & Local Authenticate, choose one you need  
Local Authenticate — In this situation, do not need Radius server in the network, all authentication completed  
by 802.1x Switchthe normal topologies as below  
1. Enter802.1X Port Status Configuration, there are 3“Authenticate authorization” states  
Auto: enables 802.1X authentication and causes the port to begin in the unauthorized state, allowing only  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EAPOL frames to be sent and received through the port. It’s a default status  
Force authorized: disables 802.1X authentication and causes the port to transition to the authorized state  
without any authentication exchange required. The port transmits and receives normal traffic without  
802.1X-based authentication of the client. This is the default setting.  
Force unauthorized: causes the port to remain in the unauthorized state, ignoring all attempts by the client  
to authenticate. The switch cannot provide authentication services to the client through the interface.  
Maximum account number: the biggest user's quantity of passing authentication under this port, set 1,  
Only one user can pass this authenticationThe second user is unable to carry on authentication on this  
portThe max value is 32  
Current account number: show the current user who passed authentication under one port.  
2. Enter”802.1X Local Authenticate” to set legitimate user information: In the local server model, the need  
for each port through the establishment of the legitimate user authentication information available. As  
Figure2-45  
3. “Other configuration”: only choose “Local Authenticate” mode is available. If you not have good  
experiences please keep the default value.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Radius Server — In this situation, need a Radius server in the network, the normal topologies as below  
1. Select the “Radius Server” mode.  
2. The RADIUS Server configuration table includes the following fields:  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The IP address of the RADIUS server being added.  
RADIUS Server IP  
Address  
The UDP port used by this server. The valid range is 0 - 65535.  
Authentication  
The default UDP Port No. is 1812  
Port(1-65535)  
The UDP port used by accounting server. The valid range is 0 -  
65535.  
Account  
Port(1-65535)  
The default UDP Port No. is 1813  
Indicates if the shared secret for this server has been  
configured.  
Share Key  
3. Setup the RADIUS server and assign the client IP address to the Web-Smart switch. In this case, field in  
the default IP Address of the Web-Smart switch with 192.168.0.100. And also make sure the shared secret  
key is as same as the one you had set at the switch RADIUS server – 12345678 at this case.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Configure ports attribute of 802.1X, the same as “802.1X Port Status Configuration”.  
5. Create user data. That step are different of “Local Authenticate”, the establishment of the user data needs  
Download from Www.Somanuals.com. All Manuals Search And Download.  
to be created on the Radius Server PC. For example, the Radius Server founded on Win2000 Server, and  
then:  
Enter ” Active Directory Users and Computers”, create legal user data, the next,  
right-click a user what you created to enter properties, and what to be noticed:  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. The last, run your 802.1X Client  
4.7.6.3 802.1X Client Configuration  
Windows XP is originally 802.1X support. As to other operating systems (windows 98SE, ME, 2000), an 802.1X  
client utility is needed. The following procedures show how to configure 802.1X Authentication in Windows XP.  
Please note that if you want to change the 802.1x authentication type of a wireless client, i.e. switch to EAP-TLS  
from EAP-MD5, you must remove the current existing wireless network from your preferred connection first, and  
add it in again.  
Configure Sample: EAP-MD5 Authentication  
1. Go to Start > Control Panel, double-click on “Network Connections”.  
2. Right-click on the Local Network Connection.  
3. Click Properties” to open up the Properties setting window.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Select Authentication” tab.  
5. Select Enable network access control using IEEE 802.1X” to enable 802.1x authentication.  
6. Select MD-5 Challenge” from the drop-down list box for EAP type.  
7. Click OK”.  
8. When wireless client has associated with WGSW-2840/5240, a user authentication notice appears in system  
tray. Click on the notice to continue.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9. Enter the user name, password and the logon domain that your account belongs.  
10. Click OK” to complete the validation process.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.8 QoS  
4.8.1 Understand QOS  
Quality of Service (QoS) is an advanced traffic prioritization feature that allows you to establish control over  
network traffic. QoS enables you to assign various grades of network service to different types of traffic, such as  
multi-media, video, protocol-specific, time critical, and file-backup traffic.  
QoS reduces bandwidth limitations, delay, loss, and jitter. It also provides increased reliability for delivery of your  
data and allows you to prioritize certain applications across your network. You can define exactly how you want the  
switch to treat selected applications and types of traffic.  
You can use QoS on your system to:  
Control a wide variety of network traffic by:  
Classifying traffic based on packet attributes.  
Assigning priorities to traffic (for example, to set higher priorities to time-critical or business-critical  
applications).  
Applying security policy through traffic filtering.  
Provide predictable throughput for multimedia applications such as video conferencing or voice over IP by  
minimizing delay and jitter.  
Improve performance for specific types of traffic and preserve performance as the amount of traffic grows.  
Reduce the need to constantly add bandwidth to the network.  
Manage network congestion.  
QoS Terminology  
Classifierclassifies the traffic on the network. Traffic classifications are determined by protocol, application,  
source, destination, and so on. You can create and modify classifications. The Switch then groups classified traffic  
in order to schedule them with the appropriate service level.  
DiffServ Code Point (DSCP) is the traffic prioritization bits within an IP header that are encoded by certain  
applications and/or devices to indicate the level of service required by the packet across a network.  
Service Leveldefines the priority that will be given to a set of classified traffic. You can create and modify  
service levels.  
Policycomprises a set of “rules” that are applied to a network so that a network meets the needs of the business.  
That is, traffic can be prioritized across a network according to its importance to that particular business type.  
QoS Profileconsists of multiple sets of rules (classifier plus service level combinations). The QoS profile is  
assigned to a port(s).  
Rulescomprises a service level and a classifier to define how theSwitch will treat certain types of traffic. Rules  
are associated with a QoS Profile (see above).  
To implement QoS on your network, you need to carry out the following actions:  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1.  
2.  
3.  
4.  
Define a service level to determine the priority that will be applied to traffic.  
Apply a classifier to determine how the incoming traffic will be classified and thus treated by the Switch.  
Create a QoS profile which associates a service level and a classifier.  
Apply a QoS profile to a port(s).  
4.8.2 QOS Configuration  
QoS settings allow customization of packet priority in order to facilitate delivery of data traffic that might be affected  
by latency problems. The IEEE 802.1p Priority specification uses 8 priority levels to classify data packets. In  
802.1p compliant devices, a tag inserted into the packet header is used to identify the priority level of data packets.  
The Switch supports four kinds of Traffic classifiers: 802.1P/ Port/MAC/VLANs and four queues.  
1. MAC-COS Mapping  
QoS settings allow customization of MAC address to Traffic classifiers.  
1. Fill the MAC Address field in the MAC-CoS Mapping Configuration Table in the In the format  
“xx-xx-xx-xx-xx-xx “.  
2. Fill the mapping number in the CoS (0-7) field.  
3. Click on the “OK” button to save.  
4. To remove the MAC-CoS mapping item, simply click on the “Delete” button in the Show MAC-CoS Mapping  
table.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2. VLAN-COS Mapping  
QoS settings allow customization of VLAN ID to Traffic classifiers  
1. Fill the VID (1-2094) field in the VLAN-CoS Mapping Table.  
2. Fill the mapping number in the CoS (0-7) field.  
3. Click on the “OK” button to save.  
4. To remove the VLAN-CoS mapping item, simply click on the “Delete” button in the Show VLAN-CoS  
Mapping table.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. 802.1p-CoS Mapping  
QoS settings allow customization of packet priority in order to facilitate delivery of data traffic that might be affected  
by latency problems. The IEEE 802.1p Priority specification uses 8 priority levels to classify data packets. In  
802.1p compliant devices, a tag inserted into the packet header is used to identify the priority level of data packets.  
1. Fill the 802.1p Priority (0-7) field in the 802.1p-priority-CoS Mapping Configuration Table.  
2. Fill the mapping number in the CoS (0-7) field.  
3. Click on the “OK” button to save.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Port-COS Mapping  
QoS settings allow customization of VLAN ID to Traffic classifiers  
1. Fill the Port List (e.g. 1-3,7) field in the port-based QoS Configuration Table.  
2. Fill the mapping number in the CoS (0-7) field.  
3. Click on the “OK” button to save.  
5. COS-Queue Mapping  
1. Fill the CoS (0-7) field in the CoS-Queue Mapping Configuration Table.  
2. Fill the mapping number in the Queue (0-3) field.  
3. Click on the “OK” button to save.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Queue Management  
There are two rules for the Priority Queue: Weighted Round Robin (WRR) and Always Hight.  
To configure Queue Rule, select the Queue Policy drop down menu in the Queue Rule Configuration table. And  
Click on the “OK” button to save.  
If the WRR was chosen as the Queue Policy, the page would show in the main page.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.9 Multicast  
4.9.1 IGMP Snooping  
Theory  
Computers and network devices that want to receive multicast transmissions need to inform nearby routers that  
they will become members of a multicast group. The Internet Group Management Protocol (IGMP) is used to  
communicate this information. IGMP is also used to periodically check the multicast group for members that are no  
longer active. In the case where there is more than one multicast router on a sub network, one router is elected as  
the ‘queried’. This router then keeps track of the membership of the multicast groups that have active members.  
The information received from IGMP is then used to determine if multicast packets should be forwarded to a given  
sub network or not. The router can check, using IGMP, to see if there is at least one member of a multicast group  
on a given subnet work. If there are no members on a sub network, packets will not be forwarded to that sub  
network.  
IGMP Versions 1 and 2  
Multicast groups allow members to join or leave at any time. IGMP provides the method for members and  
multicast routers to communicate when joining or leaving a multicast group.  
IGMP version 1 is defined in RFC 1112. It has a fixed packet size and no optional data.  
The format of an IGMP packet is shown below:  
IGMP Message Format  
Octets  
0
8
16  
31  
Type  
Response Time  
Group Address (all zeros if this is a query)  
Checksum  
The IGMP Type codes are shown below:  
Type Meaning  
0x11 Membership Query (if Group Address is 0.0.0.0)  
0x11 Specific Group Membership Query (if Group Address is Present)  
0x16 Membership Report (version 2)  
0x17 Leave a Group (version 2)  
0x12 Membership Report (version 1)  
IGMP packets enable multicast routers to keep track of the membership of multicast groups, on their respective  
sub networks. The following outlines what is communicated between a multicast router and a multicast group  
member using IGMP.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
A host sends an IGMP “report” to join a group  
A host will never send a report when it wants to leave a group (for version 1).  
A host will send a “leave” report when it wants to leave a group (for version 2).  
Multicast routers send IGMP queries (to the all-hosts group address: 224.0.0.1) periodically to see whether any  
group members exist on their sub networks. If there is no response from a particular group, the router assumes  
that there are no group members on the network.  
The Time-to-Live (TTL) field of query messages is set to 1 so that the queries will not be forwarded to other sub  
networks.  
IGMP version 2 introduces some enhancements such as a method to elect a multicast queried for each LAN, an  
explicit leave message, and query messages that are specific to a given group.  
The states a computer will go through to join or to leave a multicast group are shown below:  
Non-Member  
Leave Group  
Leave Group  
(Stop Timer)  
Join Group  
(Send Report,  
Start Timer)  
Query Received  
(Start Timer)  
Delaying Member  
Idle Member  
Report Received  
(Stop Timer)  
Timer Expried  
(Send report)  
IGMP State Transitions  
IGMP Snooping Configuration  
The default status of the IGMP Snooping function is disabled. To turn on the IGMP Snooping, select “Enable” of  
the IGMP Snooping Status field and click on the “OK” button to save.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
This function is to configure ports to be the member of IGMP Groups in VLANs.  
To do this, fill the Port List field and the VID field for the static routing and click on the “Add” button to save.  
4.10 Port Analysis  
This function shows the statistical information of each port, it helps to diagnose the network malfunction.  
The following example shows the statistic table of port #6.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.10.2 Port Mirror  
Port Mirroring is a method of monitoring network traffic that forwards a copy of each incoming and/or outgoing  
packet from one port of a network switch to another port where the packet can be studied. It enables the manager  
to keep close track of switch performance and alter it if necessary.  
Configuring the port mirroring by assigning a source port from which to copy all packets and a sniffer port where  
those packets will be sent.  
Capture Port: Use this option to select the destination port for monitored traffic. This is the port that your network  
analyzer would be connected to.  
Ingress Port: Duplicate the date transmitted from the source port and forward it to the Capture port.  
Egress Port: Duplicate the data sent to the source and forward it to the Capture port.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.11 Storm Control  
This function is to control the Braodcast Storm, Multicast Storm and Flooded Storm packet on each port.  
To configure the Storm Control, click on the Storm Control menu button. The web main page then shows the  
Strom Restricting function table.  
1. Fill the Port List field in the Broadcast Storm Restricting table, select the type in the Restricting Type drop  
down menu and enter the packet size in the Flow field.  
2. Click on the “OK” button to save.  
3. To remove the Storm Restricting function on the port, simpy click on the “Delete” button in the Show Port  
Restricting Table table.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.12 IP Stacking  
4.12.1 About IP Stacking  
IP Stacking function enables you to use a single IP address and standard network cabling to manage a group of  
up to 8 PLANET WSW-2401A/WGSW-2840/5240 switches in the same IP subnet (broadcast domain).  
Once one switch had been operated as the Master of a stack, additional switches can join the IP stack by manual  
methods to setting with the same group name. After a switch becomes a Client and stack group member, you can  
work through the Master switch to further configure the Member switch as necessary for all of the IP Stack  
features available in the switch.  
4.12.2 IP Stacking Configuration  
Before the IP Stacking Configuration, the network manager have to identify the roles of the stackable switches –  
the Master mode and Client mode. At a IP stacking group domain, there is only one Master switch and many  
Client switches. If there’re more than one switch be configured to the Master mode, the it will depends on the  
“System Priority” to elect a active Master. The others with Master mode would be Backup Master.  
To join a IP Stack group, both the Master and Client have to be assigned with the same string at “IP Stacking  
Group” filed.  
Once the switch be assigned as a Client switch, it’s not allowed to management the Client switch with its original  
system IP address. That is, the administrator has to configure the Client switch via the Master switch  
mamagement UI.  
The following fields can be set for IP Stacking configuration:  
Current mode: Display the current mode of IP Stacking, there’re three possible statuses:  
Disable – The IP Stacking function is disabled.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Master – The IP Stacking Management status is enabled and the current switch is a Master switch at this  
IP Stack Group.  
Client.- The IP Stacking Management status is enabled and the current switch is a Client switch at this IP  
Stack Group.  
Manamement status: This filed is to Enable or Disable the IP Stack function.  
Management mode: Identify the management mode of the current switch. There’re two possible selections:  
Master – The switch plays as a Master of the IP Stack Group.  
Client - The switch plays as a Client of the IP Stack Group.  
IP Stacking group: This filed effects if the switches be joined to the same IP Stack group. With the same “string”  
entry, both the Master and Client will be assigned to the same IP Stack group. If not, the switches will not be the IP  
Stack group members.  
System priority: If there’re more than one switch be configured to the Master mode, the it will depends on the  
“System Priority” to elect a active Master. The others with Master mode would be Backup Master. If there is no  
other Master switch, it’s no need to modify this value.  
IPStacking MAC: The Master will base on the MAC address to find out the Cleint switches. Generally the entry  
would be the burn-in MAC address of the switch.  
Stack name: Identify the name at a IP Stack group. The entry will be displayed at the Master switch management  
UI for Master and Client switches identify.  
Following we’ll show you how to configure the Master switch and Client switch.  
Master Switch configuration  
1. Please enter into switch web main screen and choose “Enable” in Management status field. It will enable the  
stack function of the switch and the following screen appears.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Then assign a role to the WGSW-2840 as Master in Management mode field, the following screen appears.  
3. Enter a string in the “IP Stacking Group” field; the default string of the WGSW-2840/5240 is “planet_switch”.  
This string must be the same with the Client switches that to be assigned to the same IP Stack group.  
4. Modify the “System priority” and “Stack name” if necessary. At this sample we change the Stack name of the  
Master to “Switch-1”  
5. Click OK” if the configuration is down.  
Client Switch configuration  
6. Please enter into Client switch web main screen and choose “Enable” in Management status field. It will  
enable the stack function of the switch.  
7. Then assign a role to the WGSW-2840 as Client in Management mode field, the following screen appears.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Enter a string in the “IP Stacking Group” field; the default string of the WGSW-2840/5240 is “planet_switch”.  
This string must be the same with the Master switch that to be assigned to the same IP Stack group.  
9. Modify the “System priority” and “Stack name” if necessary. At this sample we change the Stack name of  
the Client to “Switch-2”  
10. Click OK” if the configuration is down.  
11. Please use a UTP cable to uplink together through its Ethernet interface  
12. Back to login the WEB main screen of Master switch- then you can see two WGSW-2840 stacks together  
from its web interface. The following screen appears.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13. After setup complete, please go to system and choose “Saving parameters” to save current configuration.  
The following screen appears.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. TROUBLE SHOOTING  
This section is intended to help you solve the most common problems on the WSD-800 Managed Ethernet Switch  
5.1 Incorrect connections  
The switch port can auto detect straight or crossover cable when you link switch with other Ethernet device. For  
the RJ-45 connector should use correct UTP or STP cable, 10/100Mbps port use 2 pairs twisted cable. If the  
RJ-45 connector is not correct pin on right position then the link will fail. For fiber connection, please notice that  
fiber cable mode and fiber module should be match.  
5.1.1 Faulty or loose cables  
Look for loose or obviously faulty connections. If they appear to be OK, make sure the connections are snug. IF  
that does not correct the problem, try a different cable.  
5.1.2 Non-standard cables  
Non-standard and miss-wired cables may cause numerous network collisions and other network problem, and can  
seriously impair network performance. A category 5-cable tester is a recommended tool for every 100Base-T  
network installation.  
5.1.3 Improper Network Topologies  
It is important to make sure that you have a valid network topology. Common topology faults include excessive  
cable length and too many repeaters (hubs) between end nodes. In addition, you should make sure that your  
network topology contains no data path loops. Between any two ends nodes, there should be only one active  
cabling path at any time. Data path loops will cause broadcast storms that will severely impact your network  
performance.  
5.2 Diagnosing LED Indicators  
The Switch can be easily monitored through panel indicators to assist in identifying problems, which describes  
common problems you may encounter and where you can find possible solutions.  
IF the power indicator does turn on when the power cord is plugged in, you may have a problem with power outlet,  
or power cord. However, if the Switch powers off after running for a while check for loose power connections,  
power losses or surges at power outlet. IF you still cannot resolve the problem, contact your local dealer for  
assistance.  
5.2.1 Cabling  
RJ-45 ports: use unshielded twisted-pair (UTP) or shield twisted-pair (STP) cable for RJ-45 connections: 100Ω  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Category 3, 4 or 5 cable for 10Mbps connections or 100Category 5 cable for 100Mbps connections. Also be  
sure that the length of any twisted-pair connection does not exceed 100 meters (328 feet).  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. APPENDIX  
6.1 Console Port Pin Assignments  
The DB-9 serial port on the front panel is used to connect to the switch for out-of-band console configuration. The  
console menu-driven configuration program can be accessed from a terminal or a PC running a terminal emulation  
program. The pin assignments used to connect to the serial port are provided in the following tables.  
DB-9 Console Port Pin Numbers  
DB-9 Port Pin Assignments  
CCITT  
Signal  
Switch’s DB9 DTE  
Pin #  
PC DB9  
EIA Circuit  
Description  
DTE Pin #  
BB  
BA  
AB  
104  
103  
102  
RxD (Received Data)  
TxD (Transmitted Data)  
SGND (Signal Ground)  
2
3
5
2
3
5
Console Port to 9-Pin DTE Port on PC  
Switch’s 9-Pin Serial Port  
CCITT Signal PC’s 9-Pin  
DTE Port  
2 RXD  
3 TXD  
<---------RXD ------------  
-----------TXD ---------->  
-----------SGND ----------  
3 TxD  
2 RxD  
5 SGND  
5 SGND  
Cable Types and Specifications  
Cable  
Type  
Max. Length  
Connector  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
10BASE-T  
Cat. 3, 4, 5100-ohm  
Cat. 5 100-ohm UTP  
UTP 100 m (328 ft)  
100 m (328 ft)  
RJ-45  
RJ-45  
100BASE-TX  
50/125 or 62.5/125 micron  
core multimode fiber (MMF)  
100BASE-FX  
2 km (1.24 miles)  
SC or ST  
6.2 100BASE-TX/10BASE-T Pin Assignments  
With 100BASE-TX/10BASE-T cable, pins 1 and 2 are used for transmitting data, and pins 3 and 6 for receiving  
data.  
RJ-45 Pin Assignments  
Pin Number  
Assignment  
1
2
3
6
Tx+  
Tx-  
Rx+  
Rx-  
Note: "+" and "-" signs represent the polarity of the wires that make up each wire pair.  
All ports on this switch support automatic MDI/MDI-X operation, you can use straight-through cables for all  
network connections to PCs or servers, or to other switches or hubs. In straight-through cable, pins 1, 2, 3, and 6,  
at one end of the cable, are connected straight through to pins 1, 2, 3 and 6 at the other end of the cable. The table  
below shows the 10BASE-T/ 100BASE-TX MDI and MDI-X port pin outs.  
Pin MDI-X  
Signal Name  
MDI Signal Name  
1
2
3
6
Receive Data plus (RD+)  
Receive Data minus (RD-)  
Transmit Data plus (TD+)  
Transmit Data minus (TD-)  
Transmit Data plus (TD+)  
Transmit Data minus (TD-)  
Receive Data plus (RD+)  
Receive Data minus (RD-)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
7. APPENDIX-B  
802.1Q VLAN Multi-Untagged VLAN setting sample 1  
The version V.1.4.27 of WGSW-2840 had added the multiple untagged VLAN function on a port. The function  
could be applied at if the members of two or more different VLAN groups all have to access the same  
server/AP/Printer. But the two VLAN groups are separated and can’t access to each other. The graphic in Figure  
7-1 appears.  
Figure 7-1 Overlap VLAN graphic  
The next will be a configure sample- how to setup the WGSW-2840 802.1Q VLAN with a multiple untagged port.  
1. At the menu bar ,click “Security” > “ VLAN”  
2. After the VLAN configuration page appear, select “802.1Q VALN“ and clink “OK” to apply. Then the following  
screen in Figure 7-2 appears.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 7-2 802.1Q VLAN page screen  
3. Move the mouse course to the port, which had be assigned to be connect to the server/AP/printer, then click  
on the port. For this case, we set the Port-1 to be the multiple untagged port. The screen in Figure 7-3  
appears.  
4. At the Link Type, select “Always Untag” at the draw bar. Click “OK” to apply.  
Figure 7-3 802.1Q VLAN Port Configuration – Port1 screen  
5. Click the “Add/Modify” button to create new VLAN groups with VID=2 and VID=3.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. At the Port 1-VLAN Port configuration page, select VLAN 2 and VLAN 3 to add to the Port 1. The right  
information window at this table shows the status. The screen in Figure 7-4 appears.  
Figure 7-4 Assign Port-1 to be VLAN 2 and VLAN 3 member.  
7. After the down the Port 1 VLAN configuration, press “close” to back to the 802.1Q VLAN main screen. And  
check if the setting be applied to Port 1 at the “Egress Policy” column. The screen in Figure 7-5 appears.  
Figure 7-5 Port 1 VLA N status  
8. Assign the VLAN 2 and VLAN 3 group member. At this case, Port 2 had been assigned to as VLAN 2 group  
member and Port 3 be assigned to as VLAN 3 group member.  
9. Repeat step 2 to step 7, expect that :  
Configure the Port 2 with PVID=2, Port 3 with PVID=3.  
The link type of both Port-2 and Port 3 are “Always Untag”.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
And both Port 2 and Port 3 are VLAN 1 members.  
10. After properly configure the 802.1Q VLAN per port setting, it should be as the screen in Figure 7-6 appears.  
Figure 7-6 Port 1, Port 2 and Port 3 VLAN configuration  
Although Port 2 and Port 3 are VLAN 1 members, with different PVID setting, the two ports are not able to access  
each other. But they all can access with the server/AP/Printer which connect to the Port 1 now.  
Part No. 2081-A92310-001  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Perception Digital MP3 Player PD 200 User Manual
Philips Flat Panel Television 191TV4L User Manual
Philips Iron GC3360 User Manual
Pioneer Car Stereo System VP 1000 User Manual
Pioneer Home Theater System S DV700ST User Manual
Playskool Games 6168020000 User Manual
Porter Cable Paint Sprayer PSH3 User Manual
Poulan Trimmer 530164693 User Manual
Poulan Trimmer FL26 User Manual
Proxima ASA Projector 4100 4200 User Manual