Installation
The default switch settings (all switches in the UP position) will
work for most installations. See the Operation section of this guide
for more details.
The converter comes equipped with a bank of DIP switches and
set of jumpers for setting configuration.
The following steps are used to configure the Media Converter.
1. Set the DIP switch settings (optional).
2. Insert the SFP modules (purchased separately) into the
transceiver ports.
3. Connect the power cord strain relief clip (optional) and
connect and apply power.
DIP Switch Settings
The DIP switches are accessible through the opening in the side
of the enclosure.
Link Mode (Switch 1)
Switch Position Mode
Up (default)
Down
Smart Link Pass-Through Mode
Standard Mode
Smart Link Pass-Through: In this mode, the fiber link state on
one connection is directly reflected through the Media Converter to
the other fiber connection. Since this media converter is protocol
independent, it monitors the Signal Detect indicator from the SFP
3
Download from Www.Somanuals.com. All Manuals Search And Download.
and reflects this on the TX port of the other SFP by turning off the
transmitter. When the signal (Link) gets restored and Signal
Detector becomes active the affected transmitter gets re-enabled.
Standard Mode: In Standard Mode the media converter will
monitor the fiber link in the same manner. If Signal Detect goes
down the media converter will output a 25MHz signal on the TX
port of the other SFP.
Fiber Fault Alert (Switch 2)
Switch Position Mode
Up (default)
Down
Enabled
Disabled
Enabled: If the media converter detects a loss of fiber signal on its
fiber receiver, it will disable its fiber transmitter on the same SFP.
This, in effect, notifies the fiber link partner that an error condition
exists on the fiber connection.
Disabled: The Protocol Transparent Media Converter will not
monitor for Fiber Fault.
Rate Select (Switch 3)
Switch Position Mode
Up (default)
Down
High Speed
Low Speed
High Speed – When a multi-rated SFP is inserted, it is enabled for
its higher speed of operation.
Slow Speed – When a multi-rated SFP is inserted, it is enabled
for its slower speed of operation.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Attaching the Power Cord Strain Relief
Clip
For extra power cable strain relief, attach the strain clip to the side
of the unit, then thread the power cable through the clip in either
one or two loops.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Powering up the Perle Media Converter
1. Connect the Perle supplied power adapter to the media
converter.
2. Turn on the power at the source.
3. Check that the PWR LED light is lit.
Terminal Block Connector
1. Ensure the Power Source is off prior to connection.
2. Strip insulator sheathing from both wires 5mm (3/16th
inch) to expose the copper conductor wire.
3. Loosen the terminal block screws and connect Positive (+)
wire to the left terminal. Connect the Negative (-) wire to
the right terminal. Tighten Terminal screws (0.22Nm-
0.25Nm torque).
4. Turn on power source.
5. Check that the PWR LED light is lit.
Status LED
There are three status LEDs located on the front of the unit.
PWR
On – Power is applied to the unit
Blinking Fast – Hardware Error
LK1
On – Signal Detected
Off – No Signal Detected
LK2
On – Signal Detected
Off – No Signal Detected
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Specifications
Extended
Temperature
Max Power Input
Commercial
Consumption
6-30 VDC 0.625A
Max
325mA at 12VDC 325mA at 12VDC
Operating
0°C - 50°C
-40°C - 75°C
Temperature
(32°F - 122°F)
(-40°F - 167°F)
-25°C - 70°C
(-13°F - 158°F)
-40°C - 85°C
(-40°F - 158°F)
Storage Temperature
Operating Humidity
Storage Humidity
Operating Altitude
5% to 90% non-condensing
5% to 95% non-condensing
Up to 3,048 m (10,000 ft)
Note: Please refer the product page on the Perle website for the
most up to date models and specifications.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Compliance Information
EMI/EMC
EN 55022/CISPR22
EN 55022/CISPR22
FCC
This product has been found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions in this Guide, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference, in which case the user will be required to correct the interference at
his/her own expense.
Safety
IEC 60950-1 2nd edition
UL 60950-1 CAN/CSA STD C22.2 No 60950-1
Warning: If this unit is to be installed in a location where the
ambient temperature exceeds 50C, the case temperature may
exceed safe levels. For this reason, this unit should installed in a
restricted access location.
Warranty / Registration
Perle’s standard Lifetime Warranty provides customers with return
to factory repairs for Perle products that fail under the conditions of
the warranty coverage. Details can be found at:
Contacting Technical Support
Contact information for the Perle Technical Assistance Center
(PTAC) can be found at the link below. A Technical Support Query
may be made via this web page.
Copyright© 2013 Perle Systems Limited
All rights reserved. No part of this document may be reproduced or used in any form
without written permission from Perle Systems.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
|