| AquaLumin® II - Nicheless Light   Installation Guide   IMPORTANT SAFETY INSTRUCTIONS   READ AND FOLLOW ALL INSTRUCTIONS   SAVETHESE INSTRUCTIONS   Contents   Section   1. Installing a mounting bracket and light fixture during new vinyl pool construction...........3   2. Replacing light fixture in existing pools......................................................................7   3. Replacing a lamp only..............................................................................................10   Parts List / Replacement Part Kits........................................................................13-15   Minimum Qualifications   • • • Licensed or Certified Electrician   Electrician or Qualified Pool Serviceman   Qualified Pool Serviceman or Homeowner   IMPORTANT NOTICE   This AquaLumin II light will install only with the following AquaLumin II Mounting Brackets,   manufactured after JUNE 6, 1994:   AquaLumin II Vinyl Mounting Bracket Assembly 1"   AquaLumin II Vinyl Mounting Bracket Assembly 3/4"   (P/N78887800)   (P/N78887700)   BACK VIEW   Housing   spacer   Housing   Mounting   spacer   Mounting   bracket   AquaLumin II - Manufactured after June 6, 1994   P/N 99460100 Rev E - 01/15/08   P/N 99460100 Rev E - 01/14/08   Download from Www.Somanuals.com. All Manuals Search And Download.   3 14   Light Assembly Parts   Section 1: Installing a mounting bracket and light fixture during new vinyl   pool construction   1 D A N G E R !   RISK OF ELECTRICAL SHOCK OR ELECTROCUTION   This Nicheless light fixture must be installed by a licensed or certified electrician or   a qualified pool serviceman in accordance with the National Electrical Code and all   applicable local codes and ordinances. Improper installation will create an electrical   hazard which could result in death or serious injury to pool users, installers or   others due to electrical shock and may also cause damage to property. Always   disconnect power to the pool light at the circuit breaker before servicing the light.   Failure to do so could result in death or serious injury to serviceman, pool users or   others due to electrical shock.   2 3 4 A. Preparatory steps which must be completed by the electrician before light is installed,   see Figure 1.   5 6 1. Be sure the electrical system of the pool conforms with the requirements of the current   National Electrical Code (NEC) and all local codes and ordinances. A licensed or certified   electrician must install the electrical system to meet or exceed those requirements before   the Nicheless Light is installed. Some of the requirements of the NEC are listed below.   a. The lighting circuit must have a Ground Fault Circuit Interrupter (GFCI), and have an   appropriatelyrated   circuit breaker.   48"   AquaLumin II Replacement Parts   TO GFCI, CIRCUIT   MIN.   b. The junction box (or, for   12 volt models, the low   voltage transformer) is   located at least 12   BREAKER AND   12" MIN. FROM BOTTOM   OF JUNCTION BOX   OR LOW VOLTAGE   POWER SOURCE   Part   Number   TRANSFORMER TO WATER LINE   Item   1 Description   WATER   LEVEL   RIGID CONDUIT   18" MIN. FROM WATER   TO TOP OF FACE RING   619601   619632   619797   619599   Facering(white)   Face ring (black)   Lens   inches above water   PILOT SCREW AT TOP   level, and at least 48   inches from the edge of   the pool, see Figure 1.   TO EXISTING   BONDING   CONNECTOR   2 3 4 5*   Lens gasket   TOP OF FACE RING   CORRESPONDS   TO CENTER OF   MOUNTING HUB   78889900 Captivescrew   MOUNTING HUB   c. The light fixture and all   metal items within five   (5) feet of the pool must   be properly electrically   bonded.   619584   619484   619792   600140   Halogen lamp 12 volt /100 watt   Halogen lamp 120 volt / 250 watt   Sealing screws (10 req.)   Figure 1   6 Kwik change lens set (4) (not shown)   Note: (*) Sold in Bulb Replacement Kits 600139   and 600138.   AquaLumin® II - Nicheless Light Installation Guide   AquaLumin® II - Nicheless Light Installation Guide   Download from Www.Somanuals.com. All Manuals Search And Download.   13   4 Vinyl Liner Mounting Bracket Parts   Section 1: Installing a mounting bracket and light fixture during new vinyl   pool construction (Continued)   PatentNumber5,051,875   Models 250 watt / 120 volt and   100 watt / 12 volt (transformer required)   d. The mounting bracket and mounting hub must be   properly installed so that the top edge of the face ring   of the Nicheless Light is at least 18 inches below the   surface of the water in the pool. The top of the face   ring will line up with the center of the Plastic Mounting   Hub, see Figure 1 on page 3.   ( & )   e. The mounting bracket (not shown) and mounting hub   must be properly electrically bonded and grounded via   the No. 8 AWG ground connector located at the upper   left mounting bolt positioned, see Figure 2.   2. To be certain that the pool's electrical system meets all   applicable requirements, you should also consult the local   buildingdepartment.   Figure 2   3. Use only Pentair Nicheless Fixtures, (Mounting Bracket   Assembly), toensureproperbondingandgrounding   connections.   B. Perform the following steps after the electrical system requirements are met   (see Section 1A (page 3) for requirements)   1. Locate position on a vertical wall where light is to be installed. The top of the light face ring   must be 18 inches below normal water level as required by NEC Article 680.   2. Cut or punch a three (3) inch diameter hole through pool wall with center 18 inches below   normal water level for mounting hub and mounting bracket installation.   Vinyl Liner Replacement Parts   Part   3. If using plastic conduit, install PVC conduit adapter (provided) before installing plastic   mounting hub. Use only recommended sealant for PVC/ABS threads. Position mounting hub   over hole with the word “TOP” at the top, and secure with mounting flange and two (2) hex   nuts and lock washers. Tighten hex nuts evenly with equal torque.   Item   Number Description   1 2 3 4 5 6 7 619547   619548   619549   619550   Wall mounting bracket assembly   Metal bracket cup assembly   Mounting hub 3/4 in. assembly   Mounting hub 1 in. assembly   NOTE: Attach the stainless steel mounting bracket temporarily to ABS mounting hub.   Perfect top and bottom alignment of ABS hub will be easier.   78872600 Mountingspacer   619617 Housingspacer   86001800 Nipple, 1 in.   CAUTION: Remove mounting bracket before liner is installed. Failure to   remove mounting bracket can damage the liner during installation.   AquaLumin® II - Nicheless Light Installation Guide   AquaLumin® II - Nicheless Light Installation Guide   Download from Www.Somanuals.com. All Manuals Search And Download.   5 12   Section 1: Installing a mounting bracket and light fixture during new vinyl   pool construction (Continued)   Section 3: Replacing a lamp only (Continued)   13. While holding the glass lens and plastic face ring, turn the light over and place it face down   on a flat soft clean surface. Be careful not to scratch the lens.   4. Connect bonding wire from bonding grid to bonding lug on rear of the mounting hub   assembly.   14. Insert one new sealing screw, provided with the Bulb Replacement Kit, through the circular   hole located at the TOP (12 o'clock) of the back of the housing and loosely tighten it into   the face ring. Insert the remaining new sealing screw through the circular hole located at   the BOTTOM (6 o'clock) of the back of the housing and loosely tighten it into the face ring.   The BOTTOM (6 o'clock) circular hole is accessible through a hole drilled in the center of   the hook mounting bracket.   5. Before installing liner, be sure   gasket is firmly attached to   mounting hub. After liner is   installed and properly stretched   into position, locate bolt holes in   hub and punch liner for four   bracket mounting bolts. Install   the mounting spacer against the   liner and hold in position with   mounting bracket. Secure with   four (4) bracket mounting bolts   andwashers.   15. Continue to tighten all the sealing screws into the face ring. It is recommended that   opposing sealing screws be tightened in order (12 o'clock and 6 o'clock; 3 o'clock and 9   o'clock, etc.) to the recommended torque of 10-15 in-lbs. This provides even pressure on   the lens and lens gasket and creates a seal between the environment and the inside of the   light fixture.   16. Wrap a length of the cord up to a maximum of eight (8) feet long on the back of the light   assembly. Wind a maximum of three (3) wraps of cord so that the last wrap stops at the   top of the light. This extra cord allows the light to be brought out of the pool for servicing.   NOTE: If using PVC conduit, you   must attach grounding wire to   NOTE: Leave 2" to 3" of slack cord at the top so that the light may be tipped back for   removal.   grounding lug on upper left   mounting bolt positioned, see   Figure 4, on page 6.   Figure 3.   WARNING Always install a new lens gasket, part number 619599, whenever   reassembling the light. Failure to do so may permit water to leak into the assembly which   could cause; (a) an electrical hazard resulting in death or serious injury to pool users,   installer, or others due to electrical shock, or (b) breakage of the lamp or lens, which   likewise could result in serious injury to pool user, installers, or bystanders, or in damage   toproperty.   6. Wrap a length of the cord up to a maximum of eight (8) feet long on the back of the light   assembly. Wind a maximum of three (3) wraps of cord so the last wrap stops at the top of   the light. This extra cord allows you to bring the light out of the pool to install a new lamp   and for servicing.   NOTE: Leave 2" to 3" of slack cord at the top so that the light may be tipped back for   removal.   17. Feed the remaining cord through the conduit hole in the mounting hub. Place the hook   mounting bracket over the pin on the bottom of the mounting bracket. Press down   lightly to secure in place. Secure at the top of the light with the captive screw.   7. Feed the remaining cord through the conduit hole in the mounting hub. Place hook   mounting bracket over the pin on the bottom of the mounting bracket and press down   lightly to secure in place. Secure at the top of the light with the captive screw. When   installed properly, the housing spacer should fill any gap between the pool wall and the   light.   18. Before operating the light for more than 10 seconds, be sure the Nicheless Light is   completely submerged in water. To check for proper operation, switch on the main switch   or circuit breaker, as well as the switch which operates the Nicheless Light.   NOTE: If PVC conduit is being used, a #8 ground wire for U.L. or a #6 ground wire for CSA,   must be pulled through the conduit along with the light cord and fastened at the junction   box and at the grounding lug located on the light wall Mounting Bracket (the Upper left   bracket mounting bolt).   WARNING Use only the special stainless steel captive screw (see Light   Assembly Parts, item 4, on page 14) provided with this Nicheless Light. This screw   mounts and electrically grounds the housing securely to the Nicheless fixture. Failure to   use the screw provided could create an electrical hazard which could result in death or   serious injury to pool users, installers or others due to electrical shock.   AquaLumin® II - Nicheless Light Installation Guide   AquaLumin® II - Nicheless Light Installation Guide   Download from Www.Somanuals.com. All Manuals Search And Download.   11   6 Section 1: Installing a mounting bracket and light fixture during new vinyl   Section 3: Replacing a lamp only (Continued)   pool construction (Continued)   8. Cut the cord at the junction box, leaving at least six (6) inches of cord to make   connections.   WARNING: Be sure power is OFF before installing or removing lamp. Allow lamp to cool   before relamping. This light fixture uses a Halogen Quartz lamp. Do Not touch lamp with bare   9. Strip 6 inches of the outer cord jacket to expose the three insulated wires. Be careful not   to damage the insulation on the three inner wires.   hands, this may severely reduce its life. Use the plastic furnished with the replacement lamp to   eliminate finger prints from getting on lamp.   10. Connect cord to electrical wires at Junction Box, be careful to not pull the three (3) in. of   slack cord at the light through the conduit when connecting the wires. All wiring should be   connected to a Class A Ground Fault Circuit Interrupter (GFCI), in accordance with   electrical codes, see Section 1.A.1.a on page 3.   8. To remove the lamp:   a. Place the light in front of you so that the captive screw hole is at the top, and the lamp   is in a horizontal position.   11. Connect all three wires to the corresponding circuit wires in the junction box and secure   the junction box cover in place.   b. Grasp the lamp on the right side.   c. Push the lamp to the left, compressing the spring in the spring loaded lamp socket,   until the right side of the lamp comes free from the fixed socket end.   WARNING: Never operate this Nicheless Light for more than 10 seconds unless   it is totally submerged in water. Without total submersion, the light assembly will get   extremely hot, which may result in serious burns or in breakage of the lamp or lens.   This may result in serious injury to pool users, installer, or bystanders, or in damage   toproperty.   9. Install the new lamp by performing step 8, a through c, in reverse order. NOTE: Select   proper lamp for either 12 volt or 120 volt applications. Take care not to touch the halogen   bulb with bare hands.   WARNING Always install a new lens gasket, part number 619599, whenever   reassembling the light. Failure to do so may permit water to leak into the assembly which   could cause; (a) an electrical hazard resulting in death or serious injury to pool users,   installer, or others due to electrical shock, or (b) breakage of the lamp or lens, which   likewise could result in serious injury to pool user, installers, or bystanders, or in damage   toproperty.   WARNING: Use only the special stainless steel captive screw (see Light   Assembly Parts, item 4, on page 14) provided with this Nicheless Light. This screw   mounts and electrically grounds the housing securely to the Nicheless fixture. Failure   to use the screw provided could create an electrical hazard which could result in death   or serious injury to pool users, installers or others due to electrical shock.   10. Never reuse the old lens gasket when reassembling the light. Replace the old lens gasket   with a new genuine Pentair Water AquaLumin II lens gasket (P/N 619599), provided in the   Bulb Replacement Kit. The orientation of the tabs on the lens gasket is not important.   11. Replace the eight (8) sealing screws left in the face ring with eight (8) new sealing screws   provided in the Bulb Replacement Kit. NOTE: Install the new sealing screws in the same   location as those removed, leaving "TOP" (12 o'clock) and "BOTTOM" (6 o'clock) open.   12. Reinstall the lens gasket, lens and plastic face ring. While replacing the lens, be sure the   tabs around the perimeter of the lens gasket are not under the flange of the lens. Orientate   the lens so that the word "TOP" is aligned with the captive screw hole. When reinstalling   the plastic face ring, align the heads of the sealing screws with the large circular holes of   the keyway slots. Press down on the plastic face ring and rotate in the clockwise direction   until the sealing screws interfere with the housing (at the end of the slot). Orientate the   plastic face ring so that the words "MADE IN USA" are aligned with the captive screw hole   on the housing as well as the word "TOP" on the lens.   Figure 4.   12. Before operating the light for more than 10 seconds, fill pool until the Nicheless Light is   completely submerged in water. To check for proper operation, turn on main switch or   circuit breaker, as well as the switch which operates the Nicheless Light.   C. Winterizing: Light should be left in place for winterization.   AquaLumin® II - Nicheless Light Installation Guide   AquaLumin® II - Nicheless Light Installation Guide   Download from Www.Somanuals.com. All Manuals Search And Download.   7 10   Section 3: Replacing a lamp only   Section 2: Replacing light fixture in existing pools   The following steps may be performed by a qualified pool serviceman or a homeowner.   NOTE: Use ONLY the Pentair Bulb Replacement Kit when relamping (P/N 600139 - 12V/100W   or P/N 600138 - 120V/250W). See relamping installation instructions provided with the light.   WARNING: Use only the special stainless steel captive screw (see Light   Assembly Parts, item 4, on page 14) provided with this Nicheless Light. This screw   mounts and electrically grounds the housing securely to the Nicheless fixture. Failure to   use the screw provided could create an electrical hazard which could result in death or   serious injury to pool users, installers or others due to electrical shock.   WARNING Never operate this Nicheless Light for more than 10 seconds unless it is   totally submerged in water. Without total submersion, the light assembly will get extremely hot,   which may result in serious burns or in breakage of the lamp or lens. This may result in serious   injury to pool users, installer, or bystanders, or in damage to property.   IMPORTANTNOTICE   This AquaLumin II light will install only with the following AquaLumin II Mounting   Brackets, manufactured after JUNE 6, 1994.   WARNING Use only the special stainless steel pilot screw (see Light Assembly   Parts, item 4, on page 14) provided with this Nicheless Light. This screw mounts and electri-   cally grounds the housing securely to the Nicheless fixture. Failure to use the screw provided   could create an electrical hazard which could result in death or serious injury to pool users,   installers or others due to electrical shock.   D A N G E R !   RISK OF ELECTRICAL SHOCK OR ELECTROCUTION   D A N G E R !   This Nicheless light fixture must be installed by a licensed or certified electrician or   a qualified pool serviceman in accordance with the National Electrical Code and all   applicable local codes and ordinances. Improper installation will create an electrical   hazard which could result in death or serious injury to pool users, installers or   others due to electrical shock and may also cause damage to property. Always   disconnect power to the pool light at the circuit breaker before servicing the light.   Failure to do so could result in death or serious injury to serviceman, pool users or   others due to electrical shock.   RISK OF ELECTRICAL SHOCK OR ELECTROCUTION   Always disconnect power to the pool light at the circuit breaker before servicing the   light. Failure to do so could result in death or serious injury to installer, serviceman,   pool users, or others due to electrical shock.   1. Turn off main electrical switch or circuit breaker as well as the switch which operates the   Nicheless Light.   2. Unscrew the captive screw on the top of the light, then tilt the top of the light out from the   wall and lift the bottom of the light out of the bracket. Unwind the excess cable that is   stored in the back of the light.   Description   Part Number   AquaLumin II Vinyl Mounting Bracket Assembly 1"   AquaLumin II Vinyl Mounting Bracket Assembly 3/4" 78887700   78887800   3. Place the light face down on the deck on a flat soft clean surface. Take care not to scratch   the lens.   4. Using a Phillips head screwdriver, loosen (do not remove) all ten 10 screws on the back of   the light.   A. The following are preparatory steps which must be completed by the electrician or   qualified pool serviceman before replacing light fixture, see Figure 5 on page 8.   5. Using a Phillips head screwdriver, remove the two (2) screws located at the TOP   (12 o'clock) and BOTTOM (6 o'clock) on the back of the light.   1. Verify the pool meets the requirements of the current National Electrical Code and all local   codes and ordinances. A licensed or certified electrician must install the electrical system to   meet or exceed those requirements before the Nicheless Light is installed. Some of the   6. While holding the glass lens and plastic face ring, turn the light over. Rotate the face ring   in a counter-clockwise direction such that the heads of the sealing screws align with the   large circular holes of the keyways slots. Lift the plastic face ring away from the housing to   remove the lens and lens gasket.   requirements of the National Electrical Code which the pool's electrical system must meet are   as follows:   7. To remove the lens and lens gasket, gently pull on the tabs located around the perimeter of   a. The lighting circuit must have a Ground Fault Circuit Interrupter (GFCI), and an   appropriatelyratedcircuitbreaker.   the lens gasket. This will allow air to enter the housing and will assist with removal of the   lens.   AquaLumin® II - Nicheless Light Installation Guide   AquaLumin® II - Nicheless Light Installation Guide   Download from Www.Somanuals.com. All Manuals Search And Download.   9 8 Section 2: Replacing light fixture in existing pools (Continued)   Section 2: Replacing light fixture in existing pools (Continued)   B. Replacing light fixture after electrical system requirements are met   b. The junction box, or the low voltage transformer for 12 volt models, is located at least   12 inches above water level and at least 48 inches from the edge of the pool, see   Figure 5.   1. Turn off main electrical switch or circuit breaker, as well as the switch which operates the   Nicheless Light.   c. The light fixture and all metal items within five (5) feet of the pool must be properly   electricallybonded.   WARNING: Failure to bring the pool's electrical system up to code requirements   before installing this Nicheless Light will create an electrical hazard which could result   in death or serious injury to pool users, installers, or others due to electrical shock, and   may also cause damage to property.   d. The mounting bracket must be properly installed so that the top edge of the face ring   of the Nicheless Light is at least 18 inches below the surface of the water in the pool,   seeFigure 5.   2. To remove light assembly, remove captive screw at top of housing, remove light assembly   from mounting bracket, and place assembly on deck. Take care not to scratch the lens.   e. The mounting bracket and mounting hub must be properly electrically bonded and   grounded via the No. 8 AWG ground connector located at the rear of the Nicheless   fixture, see Figure 5.   3. Remove junction box cover, disconnect the light fixture wires, and pull the cord through the   conduit.   2. Consult the local building department to be certain that the pool's electrical system meets   allapplicablerequirements.   4. Feed the new light fixture cord through the conduit from the Nicheless Fixture to the   junction box.   NOTE: Depending on the length of the conduit, special tools may be required to pull the   3. Install this light fixture only in a Pentair Products mounting bracket. Mounting brackets   made by other manufacturers may not provide proper bonding and grounding connections.   cord through the conduit.   5. Wrap a length of the cord up to a maximum of eight (8) feet long on the back of the light   assembly. Wind a minimum of three (3) wraps of cord so that the last wrap stops at the top   of the light. This extra cord allows you to bring the light out of the pool for installation of a   newlampandforservicing.   48"   TO GFCI, CIRCUIT   MIN.   BREAKER AND   12" MIN. FROM BOTTOM   OF JUNCTION BOX   OR LOW VOLTAGE   POWER SOURCE   NOTE: Leave 2" to 3" of slack cord at the top so that the light may be tipped back for   TRANSFORMER TO WATER LINE   removal.   WATER   LEVEL   6. Feed the remaining cord through the conduit hole in the mounting hub. Place hook   mounting bracket over pin on the bottom of the mounting bracket and press down lightly to   secure into place. Secure at top of the light with the captive screw.   RIGID CONDUIT   18" MIN. FROM WATER   TO TOP OF FACE RING   PILOT SCREW AT TOP   7. Cut the cord at the junction box, leaving at least six (6) inches of cord to make   connections.   TO EXISTING   BONDING   CONNECTOR   8. Strip six (6) inches of the outer cord jacket from the cord to expose the three insulated   wires. Be careful not to damage the insulation on the three inner wires.   TOP OF FACE RING   CORRESPONDS   TO CENTER OF   MOUNTING HUB   MOUNTING HUB   9. Connect cord to electrical wires at Junction Box, be sure not to pull the three (3) inches of   slack cord at the back of the light through the conduit when connecting the wires. All wiring   should be connected to a Class A GFCI in accordance with electrical codes, see Section   2.A.1.a on page 7.   Figure 5   10. Connect all three wires to the corresponding circuit wires in the junction box and secure the   junction box cover in place.   11. Before operating the light for more than 10 seconds, fill pool until the Nicheless Light is   completely submerged in water. To check for proper operation, turn on main switch or   circuit breaker, as well as the switch which operates the Nicheless Light.   AquaLumin® II - Nicheless Light Installation Guide   AquaLumin® II - Nicheless Light Installation Guide   Download from Www.Somanuals.com. All Manuals Search And Download.   |