Pentair Work Light AquaLumin II User Manual

AquaLumin® II - Nicheless Light  
Installation Guide  
IMPORTANT SAFETY INSTRUCTIONS  
READ AND FOLLOW ALL INSTRUCTIONS  
SAVETHESE INSTRUCTIONS  
Contents  
Section  
1. Installing a mounting bracket and light fixture during new vinyl pool construction...........3  
2. Replacing light fixture in existing pools......................................................................7  
3. Replacing a lamp only..............................................................................................10  
Parts List / Replacement Part Kits........................................................................13-15  
Minimum Qualifications  
Licensed or Certified Electrician  
Electrician or Qualified Pool Serviceman  
Qualified Pool Serviceman or Homeowner  
IMPORTANT NOTICE  
This AquaLumin II light will install only with the following AquaLumin II Mounting Brackets,  
manufactured after JUNE 6, 1994:  
AquaLumin II Vinyl Mounting Bracket Assembly 1"  
AquaLumin II Vinyl Mounting Bracket Assembly 3/4"  
(P/N78887800)  
(P/N78887700)  
BACK VIEW  
Housing  
spacer  
Housing  
Mounting  
spacer  
Mounting  
bracket  
AquaLumin II - Manufactured after June 6, 1994  
P/N 99460100 Rev E - 01/15/08  
P/N 99460100 Rev E - 01/14/08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
14  
Light Assembly Parts  
Section 1: Installing a mounting bracket and light fixture during new vinyl  
pool construction  
1
D A N G E R !  
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION  
This Nicheless light fixture must be installed by a licensed or certified electrician or  
a qualified pool serviceman in accordance with the National Electrical Code and all  
applicable local codes and ordinances. Improper installation will create an electrical  
hazard which could result in death or serious injury to pool users, installers or  
others due to electrical shock and may also cause damage to property. Always  
disconnect power to the pool light at the circuit breaker before servicing the light.  
Failure to do so could result in death or serious injury to serviceman, pool users or  
others due to electrical shock.  
2
3
4
A. Preparatory steps which must be completed by the electrician before light is installed,  
see Figure 1.  
5
6
1. Be sure the electrical system of the pool conforms with the requirements of the current  
National Electrical Code (NEC) and all local codes and ordinances. A licensed or certified  
electrician must install the electrical system to meet or exceed those requirements before  
the Nicheless Light is installed. Some of the requirements of the NEC are listed below.  
a. The lighting circuit must have a Ground Fault Circuit Interrupter (GFCI), and have an  
appropriatelyrated  
circuit breaker.  
48"  
AquaLumin II Replacement Parts  
TO GFCI, CIRCUIT  
MIN.  
b. The junction box (or, for  
12 volt models, the low  
voltage transformer) is  
located at least 12  
BREAKER AND  
12" MIN. FROM BOTTOM  
OF JUNCTION BOX  
OR LOW VOLTAGE  
POWER SOURCE  
Part  
Number  
TRANSFORMER TO WATER LINE  
Item  
1
Description  
WATER  
LEVEL  
RIGID CONDUIT  
18" MIN. FROM WATER  
TO TOP OF FACE RING  
619601  
619632  
619797  
619599  
Facering(white)  
Face ring (black)  
Lens  
inches above water  
PILOT SCREW AT TOP  
level, and at least 48  
inches from the edge of  
the pool, see Figure 1.  
TO EXISTING  
BONDING  
CONNECTOR  
2
3
4
5*  
Lens gasket  
TOP OF FACE RING  
CORRESPONDS  
TO CENTER OF  
MOUNTING HUB  
78889900 Captivescrew  
MOUNTING HUB  
c. The light fixture and all  
metal items within five  
(5) feet of the pool must  
be properly electrically  
bonded.  
619584  
619484  
619792  
600140  
Halogen lamp 12 volt /100 watt  
Halogen lamp 120 volt / 250 watt  
Sealing screws (10 req.)  
Figure 1  
6
Kwik change lens set (4) (not shown)  
Note: (*) Sold in Bulb Replacement Kits 600139  
and 600138.  
AquaLumin® II - Nicheless Light Installation Guide  
AquaLumin® II - Nicheless Light Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
4
Vinyl Liner Mounting Bracket Parts  
Section 1: Installing a mounting bracket and light fixture during new vinyl  
pool construction (Continued)  
PatentNumber5,051,875  
Models 250 watt / 120 volt and  
100 watt / 12 volt (transformer required)  
d. The mounting bracket and mounting hub must be  
properly installed so that the top edge of the face ring  
of the Nicheless Light is at least 18 inches below the  
surface of the water in the pool. The top of the face  
ring will line up with the center of the Plastic Mounting  
Hub, see Figure 1 on page 3.  
( & )  
e. The mounting bracket (not shown) and mounting hub  
must be properly electrically bonded and grounded via  
the No. 8 AWG ground connector located at the upper  
left mounting bolt positioned, see Figure 2.  
2. To be certain that the pool's electrical system meets all  
applicable requirements, you should also consult the local  
buildingdepartment.  
Figure 2  
3. Use only Pentair Nicheless Fixtures, (Mounting Bracket  
Assembly), toensureproperbondingandgrounding  
connections.  
B. Perform the following steps after the electrical system requirements are met  
(see Section 1A (page 3) for requirements)  
1. Locate position on a vertical wall where light is to be installed. The top of the light face ring  
must be 18 inches below normal water level as required by NEC Article 680.  
2. Cut or punch a three (3) inch diameter hole through pool wall with center 18 inches below  
normal water level for mounting hub and mounting bracket installation.  
Vinyl Liner Replacement Parts  
Part  
3. If using plastic conduit, install PVC conduit adapter (provided) before installing plastic  
mounting hub. Use only recommended sealant for PVC/ABS threads. Position mounting hub  
over hole with the word “TOP” at the top, and secure with mounting flange and two (2) hex  
nuts and lock washers. Tighten hex nuts evenly with equal torque.  
Item  
Number Description  
1
2
3
4
5
6
7
619547  
619548  
619549  
619550  
Wall mounting bracket assembly  
Metal bracket cup assembly  
Mounting hub 3/4 in. assembly  
Mounting hub 1 in. assembly  
NOTE: Attach the stainless steel mounting bracket temporarily to ABS mounting hub.  
Perfect top and bottom alignment of ABS hub will be easier.  
78872600 Mountingspacer  
619617 Housingspacer  
86001800 Nipple, 1 in.  
CAUTION: Remove mounting bracket before liner is installed. Failure to  
remove mounting bracket can damage the liner during installation.  
AquaLumin® II - Nicheless Light Installation Guide  
AquaLumin® II - Nicheless Light Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
12  
Section 1: Installing a mounting bracket and light fixture during new vinyl  
pool construction (Continued)  
Section 3: Replacing a lamp only (Continued)  
13. While holding the glass lens and plastic face ring, turn the light over and place it face down  
on a flat soft clean surface. Be careful not to scratch the lens.  
4. Connect bonding wire from bonding grid to bonding lug on rear of the mounting hub  
assembly.  
14. Insert one new sealing screw, provided with the Bulb Replacement Kit, through the circular  
hole located at the TOP (12 o'clock) of the back of the housing and loosely tighten it into  
the face ring. Insert the remaining new sealing screw through the circular hole located at  
the BOTTOM (6 o'clock) of the back of the housing and loosely tighten it into the face ring.  
The BOTTOM (6 o'clock) circular hole is accessible through a hole drilled in the center of  
the hook mounting bracket.  
5. Before installing liner, be sure  
gasket is firmly attached to  
mounting hub. After liner is  
installed and properly stretched  
into position, locate bolt holes in  
hub and punch liner for four  
bracket mounting bolts. Install  
the mounting spacer against the  
liner and hold in position with  
mounting bracket. Secure with  
four (4) bracket mounting bolts  
andwashers.  
15. Continue to tighten all the sealing screws into the face ring. It is recommended that  
opposing sealing screws be tightened in order (12 o'clock and 6 o'clock; 3 o'clock and 9  
o'clock, etc.) to the recommended torque of 10-15 in-lbs. This provides even pressure on  
the lens and lens gasket and creates a seal between the environment and the inside of the  
light fixture.  
16. Wrap a length of the cord up to a maximum of eight (8) feet long on the back of the light  
assembly. Wind a maximum of three (3) wraps of cord so that the last wrap stops at the  
top of the light. This extra cord allows the light to be brought out of the pool for servicing.  
NOTE: If using PVC conduit, you  
must attach grounding wire to  
NOTE: Leave 2" to 3" of slack cord at the top so that the light may be tipped back for  
removal.  
grounding lug on upper left  
mounting bolt positioned, see  
Figure 4, on page 6.  
Figure 3.  
WARNING Always install a new lens gasket, part number 619599, whenever  
reassembling the light. Failure to do so may permit water to leak into the assembly which  
could cause; (a) an electrical hazard resulting in death or serious injury to pool users,  
installer, or others due to electrical shock, or (b) breakage of the lamp or lens, which  
likewise could result in serious injury to pool user, installers, or bystanders, or in damage  
toproperty.  
6. Wrap a length of the cord up to a maximum of eight (8) feet long on the back of the light  
assembly. Wind a maximum of three (3) wraps of cord so the last wrap stops at the top of  
the light. This extra cord allows you to bring the light out of the pool to install a new lamp  
and for servicing.  
NOTE: Leave 2" to 3" of slack cord at the top so that the light may be tipped back for  
removal.  
17. Feed the remaining cord through the conduit hole in the mounting hub. Place the hook  
mounting bracket over the pin on the bottom of the mounting bracket. Press down  
lightly to secure in place. Secure at the top of the light with the captive screw.  
7. Feed the remaining cord through the conduit hole in the mounting hub. Place hook  
mounting bracket over the pin on the bottom of the mounting bracket and press down  
lightly to secure in place. Secure at the top of the light with the captive screw. When  
installed properly, the housing spacer should fill any gap between the pool wall and the  
light.  
18. Before operating the light for more than 10 seconds, be sure the Nicheless Light is  
completely submerged in water. To check for proper operation, switch on the main switch  
or circuit breaker, as well as the switch which operates the Nicheless Light.  
NOTE: If PVC conduit is being used, a #8 ground wire for U.L. or a #6 ground wire for CSA,  
must be pulled through the conduit along with the light cord and fastened at the junction  
box and at the grounding lug located on the light wall Mounting Bracket (the Upper left  
bracket mounting bolt).  
WARNING Use only the special stainless steel captive screw (see Light  
Assembly Parts, item 4, on page 14) provided with this Nicheless Light. This screw  
mounts and electrically grounds the housing securely to the Nicheless fixture. Failure to  
use the screw provided could create an electrical hazard which could result in death or  
serious injury to pool users, installers or others due to electrical shock.  
AquaLumin® II - Nicheless Light Installation Guide  
AquaLumin® II - Nicheless Light Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
6
Section 1: Installing a mounting bracket and light fixture during new vinyl  
Section 3: Replacing a lamp only (Continued)  
pool construction (Continued)  
8. Cut the cord at the junction box, leaving at least six (6) inches of cord to make  
connections.  
WARNING: Be sure power is OFF before installing or removing lamp. Allow lamp to cool  
before relamping. This light fixture uses a Halogen Quartz lamp. Do Not touch lamp with bare  
9. Strip 6 inches of the outer cord jacket to expose the three insulated wires. Be careful not  
to damage the insulation on the three inner wires.  
hands, this may severely reduce its life. Use the plastic furnished with the replacement lamp to  
eliminate finger prints from getting on lamp.  
10. Connect cord to electrical wires at Junction Box, be careful to not pull the three (3) in. of  
slack cord at the light through the conduit when connecting the wires. All wiring should be  
connected to a Class A Ground Fault Circuit Interrupter (GFCI), in accordance with  
electrical codes, see Section 1.A.1.a on page 3.  
8. To remove the lamp:  
a. Place the light in front of you so that the captive screw hole is at the top, and the lamp  
is in a horizontal position.  
11. Connect all three wires to the corresponding circuit wires in the junction box and secure  
the junction box cover in place.  
b. Grasp the lamp on the right side.  
c. Push the lamp to the left, compressing the spring in the spring loaded lamp socket,  
until the right side of the lamp comes free from the fixed socket end.  
WARNING: Never operate this Nicheless Light for more than 10 seconds unless  
it is totally submerged in water. Without total submersion, the light assembly will get  
extremely hot, which may result in serious burns or in breakage of the lamp or lens.  
This may result in serious injury to pool users, installer, or bystanders, or in damage  
toproperty.  
9. Install the new lamp by performing step 8, a through c, in reverse order. NOTE: Select  
proper lamp for either 12 volt or 120 volt applications. Take care not to touch the halogen  
bulb with bare hands.  
WARNING Always install a new lens gasket, part number 619599, whenever  
reassembling the light. Failure to do so may permit water to leak into the assembly which  
could cause; (a) an electrical hazard resulting in death or serious injury to pool users,  
installer, or others due to electrical shock, or (b) breakage of the lamp or lens, which  
likewise could result in serious injury to pool user, installers, or bystanders, or in damage  
toproperty.  
WARNING: Use only the special stainless steel captive screw (see Light  
Assembly Parts, item 4, on page 14) provided with this Nicheless Light. This screw  
mounts and electrically grounds the housing securely to the Nicheless fixture. Failure  
to use the screw provided could create an electrical hazard which could result in death  
or serious injury to pool users, installers or others due to electrical shock.  
10. Never reuse the old lens gasket when reassembling the light. Replace the old lens gasket  
with a new genuine Pentair Water AquaLumin II lens gasket (P/N 619599), provided in the  
Bulb Replacement Kit. The orientation of the tabs on the lens gasket is not important.  
11. Replace the eight (8) sealing screws left in the face ring with eight (8) new sealing screws  
provided in the Bulb Replacement Kit. NOTE: Install the new sealing screws in the same  
location as those removed, leaving "TOP" (12 o'clock) and "BOTTOM" (6 o'clock) open.  
12. Reinstall the lens gasket, lens and plastic face ring. While replacing the lens, be sure the  
tabs around the perimeter of the lens gasket are not under the flange of the lens. Orientate  
the lens so that the word "TOP" is aligned with the captive screw hole. When reinstalling  
the plastic face ring, align the heads of the sealing screws with the large circular holes of  
the keyway slots. Press down on the plastic face ring and rotate in the clockwise direction  
until the sealing screws interfere with the housing (at the end of the slot). Orientate the  
plastic face ring so that the words "MADE IN USA" are aligned with the captive screw hole  
on the housing as well as the word "TOP" on the lens.  
Figure 4.  
12. Before operating the light for more than 10 seconds, fill pool until the Nicheless Light is  
completely submerged in water. To check for proper operation, turn on main switch or  
circuit breaker, as well as the switch which operates the Nicheless Light.  
C. Winterizing: Light should be left in place for winterization.  
AquaLumin® II - Nicheless Light Installation Guide  
AquaLumin® II - Nicheless Light Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
10  
Section 3: Replacing a lamp only  
Section 2: Replacing light fixture in existing pools  
The following steps may be performed by a qualified pool serviceman or a homeowner.  
NOTE: Use ONLY the Pentair Bulb Replacement Kit when relamping (P/N 600139 - 12V/100W  
or P/N 600138 - 120V/250W). See relamping installation instructions provided with the light.  
WARNING: Use only the special stainless steel captive screw (see Light  
Assembly Parts, item 4, on page 14) provided with this Nicheless Light. This screw  
mounts and electrically grounds the housing securely to the Nicheless fixture. Failure to  
use the screw provided could create an electrical hazard which could result in death or  
serious injury to pool users, installers or others due to electrical shock.  
WARNING Never operate this Nicheless Light for more than 10 seconds unless it is  
totally submerged in water. Without total submersion, the light assembly will get extremely hot,  
which may result in serious burns or in breakage of the lamp or lens. This may result in serious  
injury to pool users, installer, or bystanders, or in damage to property.  
IMPORTANTNOTICE  
This AquaLumin II light will install only with the following AquaLumin II Mounting  
Brackets, manufactured after JUNE 6, 1994.  
WARNING Use only the special stainless steel pilot screw (see Light Assembly  
Parts, item 4, on page 14) provided with this Nicheless Light. This screw mounts and electri-  
cally grounds the housing securely to the Nicheless fixture. Failure to use the screw provided  
could create an electrical hazard which could result in death or serious injury to pool users,  
installers or others due to electrical shock.  
D A N G E R !  
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION  
D A N G E R !  
This Nicheless light fixture must be installed by a licensed or certified electrician or  
a qualified pool serviceman in accordance with the National Electrical Code and all  
applicable local codes and ordinances. Improper installation will create an electrical  
hazard which could result in death or serious injury to pool users, installers or  
others due to electrical shock and may also cause damage to property. Always  
disconnect power to the pool light at the circuit breaker before servicing the light.  
Failure to do so could result in death or serious injury to serviceman, pool users or  
others due to electrical shock.  
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION  
Always disconnect power to the pool light at the circuit breaker before servicing the  
light. Failure to do so could result in death or serious injury to installer, serviceman,  
pool users, or others due to electrical shock.  
1. Turn off main electrical switch or circuit breaker as well as the switch which operates the  
Nicheless Light.  
2. Unscrew the captive screw on the top of the light, then tilt the top of the light out from the  
wall and lift the bottom of the light out of the bracket. Unwind the excess cable that is  
stored in the back of the light.  
Description  
Part Number  
AquaLumin II Vinyl Mounting Bracket Assembly 1"  
AquaLumin II Vinyl Mounting Bracket Assembly 3/4" 78887700  
78887800  
3. Place the light face down on the deck on a flat soft clean surface. Take care not to scratch  
the lens.  
4. Using a Phillips head screwdriver, loosen (do not remove) all ten 10 screws on the back of  
the light.  
A. The following are preparatory steps which must be completed by the electrician or  
qualified pool serviceman before replacing light fixture, see Figure 5 on page 8.  
5. Using a Phillips head screwdriver, remove the two (2) screws located at the TOP  
(12 o'clock) and BOTTOM (6 o'clock) on the back of the light.  
1. Verify the pool meets the requirements of the current National Electrical Code and all local  
codes and ordinances. A licensed or certified electrician must install the electrical system to  
meet or exceed those requirements before the Nicheless Light is installed. Some of the  
6. While holding the glass lens and plastic face ring, turn the light over. Rotate the face ring  
in a counter-clockwise direction such that the heads of the sealing screws align with the  
large circular holes of the keyways slots. Lift the plastic face ring away from the housing to  
remove the lens and lens gasket.  
requirements of the National Electrical Code which the pool's electrical system must meet are  
as follows:  
7. To remove the lens and lens gasket, gently pull on the tabs located around the perimeter of  
a. The lighting circuit must have a Ground Fault Circuit Interrupter (GFCI), and an  
appropriatelyratedcircuitbreaker.  
the lens gasket. This will allow air to enter the housing and will assist with removal of the  
lens.  
AquaLumin® II - Nicheless Light Installation Guide  
AquaLumin® II - Nicheless Light Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
8
Section 2: Replacing light fixture in existing pools (Continued)  
Section 2: Replacing light fixture in existing pools (Continued)  
B. Replacing light fixture after electrical system requirements are met  
b. The junction box, or the low voltage transformer for 12 volt models, is located at least  
12 inches above water level and at least 48 inches from the edge of the pool, see  
Figure 5.  
1. Turn off main electrical switch or circuit breaker, as well as the switch which operates the  
Nicheless Light.  
c. The light fixture and all metal items within five (5) feet of the pool must be properly  
electricallybonded.  
WARNING: Failure to bring the pool's electrical system up to code requirements  
before installing this Nicheless Light will create an electrical hazard which could result  
in death or serious injury to pool users, installers, or others due to electrical shock, and  
may also cause damage to property.  
d. The mounting bracket must be properly installed so that the top edge of the face ring  
of the Nicheless Light is at least 18 inches below the surface of the water in the pool,  
seeFigure 5.  
2. To remove light assembly, remove captive screw at top of housing, remove light assembly  
from mounting bracket, and place assembly on deck. Take care not to scratch the lens.  
e. The mounting bracket and mounting hub must be properly electrically bonded and  
grounded via the No. 8 AWG ground connector located at the rear of the Nicheless  
fixture, see Figure 5.  
3. Remove junction box cover, disconnect the light fixture wires, and pull the cord through the  
conduit.  
2. Consult the local building department to be certain that the pool's electrical system meets  
allapplicablerequirements.  
4. Feed the new light fixture cord through the conduit from the Nicheless Fixture to the  
junction box.  
NOTE: Depending on the length of the conduit, special tools may be required to pull the  
3. Install this light fixture only in a Pentair Products mounting bracket. Mounting brackets  
made by other manufacturers may not provide proper bonding and grounding connections.  
cord through the conduit.  
5. Wrap a length of the cord up to a maximum of eight (8) feet long on the back of the light  
assembly. Wind a minimum of three (3) wraps of cord so that the last wrap stops at the top  
of the light. This extra cord allows you to bring the light out of the pool for installation of a  
newlampandforservicing.  
48"  
TO GFCI, CIRCUIT  
MIN.  
BREAKER AND  
12" MIN. FROM BOTTOM  
OF JUNCTION BOX  
OR LOW VOLTAGE  
POWER SOURCE  
NOTE: Leave 2" to 3" of slack cord at the top so that the light may be tipped back for  
TRANSFORMER TO WATER LINE  
removal.  
WATER  
LEVEL  
6. Feed the remaining cord through the conduit hole in the mounting hub. Place hook  
mounting bracket over pin on the bottom of the mounting bracket and press down lightly to  
secure into place. Secure at top of the light with the captive screw.  
RIGID CONDUIT  
18" MIN. FROM WATER  
TO TOP OF FACE RING  
PILOT SCREW AT TOP  
7. Cut the cord at the junction box, leaving at least six (6) inches of cord to make  
connections.  
TO EXISTING  
BONDING  
CONNECTOR  
8. Strip six (6) inches of the outer cord jacket from the cord to expose the three insulated  
wires. Be careful not to damage the insulation on the three inner wires.  
TOP OF FACE RING  
CORRESPONDS  
TO CENTER OF  
MOUNTING HUB  
MOUNTING HUB  
9. Connect cord to electrical wires at Junction Box, be sure not to pull the three (3) inches of  
slack cord at the back of the light through the conduit when connecting the wires. All wiring  
should be connected to a Class A GFCI in accordance with electrical codes, see Section  
2.A.1.a on page 7.  
Figure 5  
10. Connect all three wires to the corresponding circuit wires in the junction box and secure the  
junction box cover in place.  
11. Before operating the light for more than 10 seconds, fill pool until the Nicheless Light is  
completely submerged in water. To check for proper operation, turn on main switch or  
circuit breaker, as well as the switch which operates the Nicheless Light.  
AquaLumin® II - Nicheless Light Installation Guide  
AquaLumin® II - Nicheless Light Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Peavey Speaker 118P User Manual
Peavey Stereo System VSX 48 User Manual
Philips Coffeemaker HD7536 User Manual
Philips CRT Television 15PT2526 User Manual
Philips Portable Radio AE6780 01 User Manual
Philips Universal Remote PM 4S 4 User Manual
Polaris Offroad Vehicle 600 RUSH User Manual
Poulan Chainsaw 2000 01 User Manual
Poulan Snow Blower 189645 User Manual
Power Acoustik Marine RADAR OV2 1600 User Manual