Pelco TV Mount IWM24 User Manual

I N S T A L L A T I O N / O P E R A T I O N  
IWM/IWM24 Series  
Wall Mount  
C288M-G (8/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Important Safety Instructions  
Read these instructions.  
1. Keep these instructions.  
2. Heed all warnings.  
3. Follow all instructions.  
4. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.  
5. Only use attachments/accessories specified by the manufacturer.  
6. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-  
supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or  
moisture, does not operate normally, or has been dropped.  
7. Installation should be done only by qualified personnel and conform to all local codes.  
8. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not  
be installed where exposed to rain and moisture.  
9. Use only installation methods and materials capable of supporting four times the maximum specified load.  
10. Use stainless steel hardware to fasten the mount to outdoor surfaces.  
11. To prevent damage from water leakage when installing a mount outdoors on a roof or wall, apply sealant around the bolt holes between  
the mount and mounting surface.  
12. Only use replacement parts recommended by Pelco.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Description  
IWM Series wall mount is designed for Spectra® Series pendant dome systems, and DF5 and DF8 fixed domes. The indoor/outdoor mounts can  
be installed directly to a wall or attached to an adapter and mounted to a corner, parapet, or pole mount. The mounts support maximum loads of  
75 lb (34 kg) and feature cable feedthrough holes to conceal wiring.  
The IWM24 Series mount has a 24 VAC, 100 VA transformer with selectable input power (120/240 VAC, 50/60 Hz).  
MODELS  
IWM-BK  
Black-finish wall mount  
IWM-GY  
Gray-finish wall mount  
IWM24-BK  
IWM24-GY  
Black-finish wall mount with 100 VA transformer inside mount to power Spectra Series pendant domes.  
Same as IWM24-BK except gray finish.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installation  
IWM-BK AND IWM-GY  
1. Determine the mounting location. If the mount is to be attached to a corner, parapet, or pole mount adapter, install the adapter plate (refer  
to the instructions supplied with the adapter). If the mount is to be attached to a wall, use the base of the IWM mount as a template and  
mark the four fastener positions on the mounting surface. Set the IWM mount to the side and prepare the holes for the fasteners.  
2. Pull the wiring through the mount. Refer to Table A for the type of video coaxial cable to use. For 24 VAC power, refer to Table B to  
determine the size of wire to use.  
3. Attach the mount securely with four fasteners of appropriate length (fasteners are not provided). Use fasteners with a maximum diameter  
of 3/8-inch (0.95 cm) (fasteners are not supplied). If you install the IWM outdoors, seal the fastener holes with an appropriate sealant to  
prevent water damage. Apply the sealant between the mount and the mounting surface.  
4. If using an NPT threaded pipe (not supplied), pull the wiring through the NPT pipe and the dome back box.  
5. Attach the dome back box to the mount arm following the instructions in the dome manual.  
6. Tighten the set screw on the mount.  
7. Refer to the manual supplied with the Spectra dome system to complete the installation.  
IWM24-BK AND IWM24-GY  
PREPARE MOUNTING SURFACE  
Determine the mounting location. If the mount is to be attached to a corner, parapet, or pole mount adapter, install the adapter plate (refer to the  
instructions supplied with the adapter). If the mount is to be attached to a wall, use the base of the IWM mount as a template and mark the four  
fastener positions on the mounting surface. Set the IWM24 mount to the side and prepare the holes for the fasteners.  
PREPARE IWM24 MOUNT FOR INSTALLATION  
SET SCREW  
ACCESS PLATE  
(IWM24-BK AND  
IWM24-GY ONLY)  
3/4-INCH NPT PLUG  
Figure 1. IWM24 Series Mount  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
2. Install the conduit fittings or glands. Refer to one of the following installation methods:  
METHOD 1 – INSTALL A CONDUIT FITTING TO THE BOTTOM OF THE MOUNT  
Remove the 0.75-inch (1.91 cm) NPT plug.  
Install a conduit fitting in the 0.75-inch NPT hole.  
METHOD 2 – INSTALL THE CONDUIT FITTINGS/GLANDS TO THE BACK OF THE MOUNT  
Insert the male end of the gland or conduit fitting into the cable hole located on the back plate of the mount.  
Hold the gland or conduit fitting in the hole with one hand while you reach, with the other hand, into the mount through the  
access hole.  
Attach the fitting nut to the gland or conduit fitting, and rotate the fitting nut to hand-tighten.  
Repeat the above steps to install a second gland or conduit fitting.  
3. The transformer is preset to operate at 120 VAC. If necessary, change the voltage selection switch to operate at 230 VAC. Refer to Figure 2.  
mount arm is shipped with extra fuses. For 120 VAC, use the 1.6A, 120 VAC, fast-acting fuse; or for 240 VAC, use the 500 mA, 240 VAC,  
fast-acting fuse.  
VOLTAGE  
SELECTION  
SWITCH  
FUSE  
HOLDER  
TRANSFORMER  
POWER  
SPARE FUSE  
STORAGE  
Figure 2. Voltage Selection Switch and Fuse Holder Location  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
PULL WIRING  
1. Refer to Table A and B for coaxial cable requirements and 24 VAC wiring distances.  
2. Pull wiring/cabling for video and power. Refer to one of the following installation methods:  
METHOD 1 – THROUGH CONDUIT FITTINGS TO THE BOTTOM OF THE MOUNT  
If you are pulling video and power cables from the bottom of the mount, first attach the mount. Then pull the cables through the conduit in  
the bottom of the mount. Continue to pull the video cable only through the top of the mount.  
METHOD 2 – THROUGH CONDUIT FITTINGS/GLANDS TO THE BACK OF THE MOUNT  
If you are pulling video and power cables through the back of the mounting plate, pull the cables through the glands or conduit under the  
transformer. Continue to pull the video cable only through the top of the mount. Attach the mount.  
ATTACH THE MOUNT TO THE SURFACE  
1. Attach the mount to the mounting surface with fasteners of an appropriate length with a maximum diameter of 3/8-inch (0.95 cm)  
(fasteners are not supplied). When installing the mount to a wall outdoors, seal the bolt holes with an appropriate sealant. Apply the  
sealant around the bolt holes between the mount and the wall.  
2. Tighten the fasteners enough to seal the gasket attached to the back of the mounting plate and create a waterproof seal.  
CONNECT INPUT POWER  
1. Connect the power to the transformer.  
a. Connect the AC High (hot) wire to the clamp on the black transformer wire. The AC High wire is labeled AC HI [HOT].  
b. Connect the AC Low (neutral) wire to the clamp on the white transformer wire. The AC Low wire is labeled AC LOW [NEUT].  
2. Connect the input ground wire to the green and yellow striped wire that is attached to the mount.  
WIRING DIAGRAM COLOR KEY  
COLOR  
DESCRIPTION  
FS02-0301-1103  
BLK  
BLACK, SOLID  
WHT  
BLU  
WHITE, SOLID  
BLUE, SOLID  
BRN  
ORG  
RED  
BROWN, SOLID  
ORANGE, SOLID  
RED, SOLID  
YEL  
YELLOW, SOLID  
GREEN & YELLOW, STRIPED  
BRN  
GRN/YEL  
BLK  
SW03-2211-0500  
2a  
2
2b  
1a  
1
1b  
YEL  
BRN  
BLU  
BLU  
RED  
ORG  
YEL  
AC HIGH  
(HOT)  
XF02-0604-0001  
120/230 VAC INPUT  
SPLICE  
AC LOW  
(NEUT)  
WHT  
GRN/YEL  
(TO DOME)  
24 VAC 100 VA OUTPUT  
Figure 3. IWM24 Wiring Diagram  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
INSTALL DOME  
1. Attach the dome back box to the mount and tighten the set screw.  
2. Make all necessary electrical connections to dome. (Use the documentation provided with the dome.)  
IMPORTANT: If you are wiring more than one dome, wire the power in each dome the same way. For example, the wiring from one side  
of the transformer must be connected to the corresponding connector on each dome. If you reverse the wiring, the cameras will be out of  
phase with each other and may produce what appears to be vertical roll when switching between cameras.  
3. Place extra fuses in the clips attached to the inside of the access plate.  
4. Replace the access plate and tighten the screws enough to compress the gasket and create a waterproof seal.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Wiring Tables  
Table A. Video Coaxial Cable Requirements  
Cable Type*  
Maximum Distance  
RG59/U  
RG6/U  
RG11/U  
750 ft (229 m)  
1,000 ft (305 m)  
1,500 ft (457 m)  
*Minimum cable requirements:  
75 ohms impedance  
All-copper center conductor  
All-copper braided shield with 95% braid coverage  
The following are the recommended maximum distances for 24 VAC applications and are calculated with a 10 percent voltage drop. (Ten percent  
is generally the maximum allowable voltage drop for AC-powered devices.)  
Table B. 24 VAC Wiring Distances  
Wire Gauge  
Total  
VA  
20  
(0.5 mm2)  
18  
(1.0 mm2)  
16  
14  
12  
10  
(6.0 mm2)  
(1.5 mm2) (2.5 mm2) (4.0 mm2)  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
283  
(86)  
451  
(137)  
716  
(218)  
1142  
(348)  
1811  
(551)  
2880  
(877)  
141  
(42)  
225  
(68)  
358  
(109)  
571  
(174)  
905  
(275)  
1440  
(438)  
94  
(28)  
150  
(45)  
238  
(72)  
380  
(115)  
603  
(183)  
960  
(292)  
70  
(21)  
112  
(34)  
179  
(54)  
285  
(86)  
452  
(137)  
720  
(219)  
56  
(17)  
90  
(27)  
143  
(43)  
228  
(69)  
362  
(110)  
576  
(175)  
47  
(14)  
75  
(22)  
119  
(36)  
190  
(57)  
301  
(91)  
480  
(146)  
40  
(12)  
64  
(19)  
102  
(31)  
163  
(49)  
258  
(78)  
411  
(125)  
35  
(10)  
56  
(17)  
89  
(27)  
142  
(43)  
226  
(68)  
360  
(109)  
31  
(9)  
50  
(15)  
79  
(24)  
126  
(38)  
201  
(61)  
320  
(97)  
28  
(8)  
45  
(13)  
71  
(21)  
114  
(34)  
181  
(55)  
288  
(87)  
EXAMPLE: An enclosure that requires 80 VA and is installed 35 feet (10 m) from the transformer would require a minimum wire gauge  
of 20 AWG.  
NOTE: Wire gauges are standard AWG or metric sizes. Distances are calculated in feet; values in parentheses are meters.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Specifications  
MECHANICAL  
UNIT WEIGHT  
IWM Series  
Construction  
Cast aluminum  
2.46 lb (1.12 kg)  
6.58 lb (2.98 kg)  
Finish  
IWM24 Series  
IWM-BK, IWM24-BK  
IWM-GY, IWM24-GY  
Cable Entry  
Black polyester powder coat  
Gray polyester powder coat  
Ratings  
IWM24 Series only  
Meets NEMA 4 and IP 56  
standards  
(Design and product specifications subject to change without  
notice.)  
IWM Series Mount  
One 0.75-inch (1.91 cm) NPT  
opening on the bottom of the  
mount  
14.629 (37.15)  
IWM24 Series Mount  
Two cable feedthrough holes  
on the mounting plate  
accommodate 0.50-inch (1.27  
cm) conduit fittings or PG13.5  
liquid-tight gland fittings. One  
0.75-inch (1.91 cm) NPT  
8.0  
(20.32)  
7.5  
(19.05)  
6.5  
(16.51)  
opening on the bottom of the  
mount for conduit connector.  
4.5 (11.43)  
Mount Method  
Secure to wall with four  
fasteners of appropriate  
length (fasteners not  
13.50 (34.30)  
5.50 (13.97)  
supplied). Use fasteners up to  
3/8-inch (0.95 cm) diameter.  
Locking Method  
Dome Mounting  
6-32 Allen-head set screw to  
tighten pipe  
Figure 4. IWM and IWM24 Series Dimension Drawing  
Dome screws directly into  
mount.  
Maximum Load  
ELECTRICAL  
IWM24 Series  
Input Power  
75 lb (34 kg)  
Switchable 120/240 VAC, 50/  
60 Hz via an internal slide  
switch  
Output Power  
Fuse  
24 VAC, 100 VA transformer  
One 1.6 A, 120 VAC fast-  
acting fuse  
One 500 mA, 240 VAC fast-  
acting fuse  
General  
Environment  
Operating Range  
Indoor/outdoor  
-50° to 120°F (-46° to 49°C)  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
PRODUCT WARRANTY AND RETURN INFORMATION  
WARRANTY  
Pelco will repair or replace, without charge, any merchandise proved defective in material or  
workmanship for a period of one year after the date of shipment.  
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or  
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following  
information:  
Exceptions to this warranty are as noted below:  
1. Model and serial number  
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number  
3. Details of the defect or problem  
Five years on FT/FR8000 Series fiber optic products.  
Three years on Genex® Series products (multiplexers, server, and keyboard).  
Three years on Camclosure® and fixed camera models, except the CC3701H-2,  
CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models,  
which have a five-year warranty.  
If there is a dispute regarding the warranty of a product which does not fall under the  
warranty conditions stated above, please include a written explanation with the product  
when returned.  
Two years on standard motorized or fixed focal length lenses.  
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series  
fixed dome products.  
Method of return shipment shall be the same or equal to the method by which the item was  
received by Pelco.  
RETURNS  
Two years on Spectra®, Esprit®, ExSite, and PS20 scanners, including when used in  
continuous motion applications.  
In order to expedite parts returned to the factory for repair or credit, please call the factory at  
(800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned  
for credit, and RA number if returned for repair).  
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).  
Two years (except lamp and color wheel) on Digital Light Processing (DLP) displays. The  
lamp and color wheel will be covered for a period of 90 days. The air filter is not covered  
under warranty.  
All merchandise returned for credit may be subject to a 20% restocking and refurbishing  
charge.  
Eighteen months on DX Series digital video recorders, NVR300 Series network video  
recorders, and EnduraSeries distributed network-based video products.  
Goods returned for repair or credit should be clearly identified with the assigned CA or RA  
number and freight should be prepaid. Ship to the appropriate address below.  
One year (except video heads) on video cassette recorders (VCRs). Video heads will be  
covered for a period of six months.  
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:  
Service Department  
Pelco  
3500 Pelco Way  
Clovis, CA 93612-5699  
Six months on all pan and tilts, scanners or preset lenses used in continuous motion  
applications (that is, preset scan, tour and auto scan modes).  
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco  
shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,  
California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident  
are not covered under this warranty.  
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are  
instructed to return goods to the USA, you may do one of the following:  
If the goods are to be sent by a COURIER SERVICE, send the goods to:  
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from  
the specific use or application made of the Products. Pelco’s liability for any claim, whether  
based on breach of contract, negligence, infringement of any rights of any party or product  
liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for  
such Products. In no event will Pelco be liable for any special, incidental or consequential  
damages (including loss of use, loss of profit and claims of third parties) however caused,  
whether by the negligence of Pelco or otherwise.  
Pelco  
3500 Pelco Way  
Clovis, CA 93612-5699 USA  
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:  
Pelco c/o Expeditors  
473 Eccles Avenue  
South San Francisco, CA 94080 USA  
Phone: 650-737-1700  
Fax: 650-737-0933  
The above warranty provides the Dealer with specific legal rights. The Dealer may also have  
additional rights, which are subject to variation from state to state.  
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union  
regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.  
REVISION HISTORY  
Manual #  
C288M  
Date  
Comments  
Original version.  
C288M-A  
C288M-B  
C288M-C  
C288M-D  
C288M-E  
C288M-F  
C288M-G  
9/97  
3/98  
5/99  
12/01  
10/03  
7/04  
8/05  
Completely revised. Includes IWM24 Series mounts.  
Included wiring diagram. Modified Section 3.2, step 3f. Changed manual pagination.  
Removed template. Revised Description and Installation instructions. Updated Dimension Drawing. Added certifications. Changed to new format.  
Modified manual to reflect changes per ECO 01-7388. Changed to new format. Removed IWM-WT model.  
Modified manual to incorporate power wiring changes per ECO 03-8870.  
Modified manual to incorporate design changes per ECO 04-9902.  
Revised manual per ECO 05-11280 to change input power and a fuse value from 230 VAC to 240 VAC.  
Pelco, the Pelco logo, Spectra, Genex, Esprit, Camclosure, and Legacy are registered trademarks of Pelco.  
Copyright2004,Pelco.  
All rights reserved.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
World Headquarters  
3500 Pelco Way  
Clovis, California 93612 USA  
USA & Canada  
Tel: 800/289-9100  
Fax: 800/289-9150  
International  
Tel: 1-559/292-1981  
Fax: 1-559/348-1120  
ISO9001  
United States | Canada | United Kingdom | The Netherlands | Singapore | Spain | Scandinavia | France | Middle East  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Pelco Universal Remote C2908M B User Manual
Philips Digital Camera SPC 300NC User Manual
Philips Microphone AEA3000 User Manual
Philips Stereo Amplifier SA5223 User Manual
Philips Switch SWV2053W User Manual
Pioneer Automobile Parts GBBT series User Manual
Pioneer Stereo Amplifier GM 4200 User Manual
Porter Cable Saw 647 T3 User Manual
Powermate Portable Generator PM0106001 User Manual
Presto Fryer 16 inch Electric Skillet User Manual