Pelco Switch SX8205R User Manual

I N S T A L L A T I O N  
SX8205R Unmanaged  
Ethernet Switch  
®
Five 10BASE-T/100BASE-TX Ports  
C2626M (2/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Important Safety Instructions  
1. Read these instructions.  
2. Keep these instructions.  
3. Heed all warnings.  
4. Follow all instructions.  
5. Do not use this apparatus near water.  
6. Clean only with dry cloth.  
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s  
instructions.  
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other  
apparatus (including amplifiers) that produce heat.  
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has  
two blades with one wider than the other. A grounding plug has two blades and a third  
grounding prong. The wide blade or the third prong are provided for your safety. If the provided  
plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.  
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience  
receptacles, and the points where they exit from the apparatus.  
11. Only use attachments/accessories specified by the manufacturer.  
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold  
with the apparatus. When a cart is used, use caution when moving the cart/apparatus  
combination to avoid injury from tip-over.  
13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has  
been damaged in any way, such as power-supply cord or plug is damaged, liquid has been  
spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or  
moisture, does not operate normally, or has been dropped.  
14. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids,  
such as vases shall be placed on the apparatus.  
15. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or  
moisture.  
16. Installation should be done only by qualified personnel and conform to all local codes.  
17. Use only installation methods and materials capable of supporting four times the maximum  
specified load.  
18. A CCC-approved power cord must be used to power this equipment when used in China.  
19. CAUTION: These servicing instructions are for use by qualified service personnel only.  
To reduce the risk of electric shock do not perform any servicing other than that contained in  
the operating instructions unless you are qualified to do so.  
C2626M (2/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
 
The product and/or manual may bear the following marks:  
This symbol indicates that dangerous voltage  
constituting a risk of electric shock is present  
within this unit.  
CAUTION:  
RISK OF ELECTRIC SHOCK.  
DO NOT OPEN.  
This symbol indicates that there are important  
operating and maintenance instructions in the  
literature accompanying this unit.  
4
C2626M (2/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Regulatory Notices  
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two  
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any  
interference received, including interference that may cause undesired operation.  
RADIO AND TELEVISION INTERFERENCE  
This equipment has been tested and found to comply with the limits of a Class A digital device,  
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection  
against harmful interference when the equipment is operated in a commercial environment. This  
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in  
accordance with the instruction manual, may cause harmful interference to radio communications.  
Operation of this equipment in a residential area is likely to cause harmful interference in which case  
the user will be required to correct the interference at his own expense.  
Changes and Modifications not expressly approved by the manufacturer or registrant of this  
equipment can void your authority to operate this equipment under Federal Communications  
Commission’s rules.  
This Class A digital apparatus complies with Canadian ICES-003.  
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.  
C2626M (2/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
 
Product Overview  
DESCRIPTION  
The SX8205R unmanaged Ethernet switch provides five 10BASE-T/100BASE-TX ports for the transport of  
bidirectional Ethernet data. Operating as a single switch in a network, the SX8205R module connects to up  
to five 10BASE-T/100BASE-TX Ethernet devices. If a larger switched network is needed, multiple SX8205R  
switches can be connected by allowing a port on each switch to be used as an uplink port. Refer to Figure 1  
for illustrations of single-switch and multiple-switch applications.  
FIVE 10/100 Mbps  
CONNECTIONS  
SX8205R  
SINGLE-SWITCH APPLICATION  
SX8205R  
SX8205R  
10/100 Mbps  
UPLINK  
FOUR 10/100 Mbps  
CONNECTIONS  
FOUR 10/100 Mbps  
CONNECTIONS  
SAMPLE OF MULTIPLE-SWITCH APPLICATION  
Figure 1. SX8205R Single-Switch and Multiple-Switch Applications  
Features of the SX8205R Ethernet switch include the following:  
Uplink port capability for easy network expansion  
User-selectable networking functions on a per-port basis:  
Autonegotiation between 10 Mbps and 100 Mbps data rates and between full-duplex  
and half-duplex modes  
10 Mbps or 100 Mbps Selectable  
Full-duplex or half-duplex mode selectable  
Enabling/disabling of flow control  
Auto MDI/MDI-X (Medium Dependent Interface/Medium Dependent Interface Crossover)  
operation  
6
C2626M (2/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Compliant with IEEE 802.3, 802.3u, and 802.3x standards  
10BASE-T/100BASE-TX compatibility with all Pelco® and third-party 10BASE-T/100BASE-TX  
Ethernet devices  
Environmentally hardened  
Designed to meet NEMA TS 2 and Caltrans traffic signal control equipment standards for  
ambient operating temperature, mechanical shock and vibration, humidity with condensation,  
high-line/low-line voltage conditions, and transient voltage protection  
NOTE: Conformal coating is required for operation in environments with relative humidity  
above 95 percent (condensing).  
No performance adjustments required  
12 VDC or 24 VAC power supply  
Stand-alone and rack-mountable modular design  
LED indicators for monitoring of 10BASE-T/100BASE-TX port status and operating power  
MODELS  
SX8205R*  
Unmanaged Ethernet switch, five 10BASE-T/100BASE-TX ports  
*The conformal coated version of SX8205R is CX8205R.  
OPTIONAL ACCESSORIES  
The following optional accessories are available:  
WM5001-3U  
Wall mount base kit for single-width module  
WM5001-3UEXP Wall mount expansion kit for single-width module  
RK5000-3U  
19-inch rack mount chassis for 14 slots (no power), 3 RUs  
19-inch rack mount chassis for 12 slots with power, 3 RUs  
External rack power supply, 1 RU, dual 120 W power outputs  
Blank filler panel, single width  
RK5000PS-3U  
EPS5000-120  
RK5001B-3U  
RK5002B-3U  
RK5001-1UEXP  
Blank filler panel, double width  
Adapter kit that allows a 3 RU single-width module to be used in RK5000PS-5U  
rack mount chassis  
C2626M (2/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
   
FRONT PANEL  
Figure 2 illustrates the front panel of the SX8205R module.  
Figure 2. Front Panel of SX8205R Module  
Reset Button: Restarts the unit  
ì
î
Power LED: Pelco badge  
NOTE: For additional information about the Power LED, refer to Troubleshooting on page 15.  
8
C2626M (2/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
REAR PANEL  
Figure 3 illustrates the rear panel of the SX8205R module.  
Figure 3. Rear Panel of SX8205R Module  
Rack Power/Alarm Connector: 4-pin connector for power/alarm connection of rack-  
ì
î
mounted module  
Stand-Alone Power Connector: 2-pin connector for power connection of stand-alone  
module; removable mating connector with screw terminals (not shown)  
ï
ñ
ó
10BASE-T/100BASE-TX Ports 1-5: RJ-45 connectors  
RJ-45 10BASE-T/100BASE-TX Port Status LED, Left: Link/activity status indicator  
RJ-45 10BASE-T/100BASE-TX Port Status LED, Right: Duplex mode/collision indicator  
For additional information about rear-panel connections, refer to Installation on page 10. For detailed  
information about the RJ-45 LEDs, refer to Troubleshooting on page 15.  
C2626M (2/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
   
Installation  
PACKAGE CONTENTS  
The following items are supplied:  
1
1
SX8205R module  
Regulated switching power supply with four plug adapters (North American, Australian, U.K.,  
and European configurations); 100-240 VAC, 50-60 Hz input, 12 VDC output  
1
1
Wall clip with two 4-40 x 0.250-inch Phillips pan head screws with lock washers (for attachment  
of single module to wall)  
SX8205R Unmanaged Ethernet Switch Installation manual (this manual)  
SETTING 10BASE-T/100BASE-TX PORT MODES OF OPERATION  
NOTE: As a matter of convenience, it is recommended that you verify the modes of operation for  
each 10BASE-T/100-BASE-TX port and then change the mode settings—if necessary—before  
mounting the SX8205R module into a rack or onto a wall.  
The SX8205R module provides various configuration options that allow you to select the desired  
modes of operation for each 10BASE-T/100BASE-TX port (ports 1-5). You can select the desired  
modes of operation by means of a TX Mode switch that is provided on the bottom of the module for  
each port (refer to Figure 4).  
TX MODE SWITCHES - PORTS 1-5  
TX Mode  
Figure 4. TX Mode Switches for 10BASE-T/100BASE-TX Ports 1-5  
10  
C2626M (2/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Using the TX Mode switch for a particular port, you can do the following:  
Enable autonegotiation or select (force) a specific data rate and duplex mode:  
Enabling autonegotiation allows the SX8205R module to automatically negotiate with  
the device to which the port is connected for data rate and duplex modes of operation:  
10 Mbps or 100 Mbps data rate and half-duplex or full-duplex mode. The highest  
common denominator of operational modes is automatically selected.  
Autonegotiation is enabled by default.  
If autonegotiation is not desired, you can select a specific data rate and duplex mode:  
Data rate configuration allows you to select 10 Mbps or 100 Mbps.  
Duplex mode configuration allows you to select half-duplex mode or full-duplex  
mode.  
Enable or disable flow control. Flow control controls data transmission at the sending device  
to avoid overfilling buffers and losing data at the receiving device. When the buffers on the  
receiving device are full, a message is sent to the sending device to suspend the transmission  
until the data in the buffers has been processed.  
NOTE: For time-sensitive data applications (for example, video and audio applications), it is  
recommended that flow control be disabled.  
Flow control is disabled by default.  
With the SX8205R module powered off, set each TX Mode switch to the desired modes of operation.  
Refer to Table A for TX Mode switch settings and corresponding 10BASE-T/100BASE-TX port modes  
of operation. Note that each 10BASE-T/100BASE-TX port operates independently of one another;  
therefore, each port can be set to different modes of operation as appropriate.  
Table A. TX Mode Switch Settings  
TX Mode  
Switch Position  
10BASE-T/100BASE-TX Modes of Operation  
0
Auto Neg/Dis FC: Enables autonegotiation between 10 Mbps and  
100 Mbps and between half-duplex and full-duplex modes, disables  
flow control (default setting)  
1
2
3
4
5
100 FD/Dis FC: Selects 100 Mbps full-duplex, disables flow control  
100 HD/DIS FC: Selects 100 Mbps half-duplex, disables flow control  
10 FD/Dis FC: Selects 10 Mbps full-duplex, disables flow control  
10 HD/Dis FC: Selects 10 Mbps half-duplex, disables flow control  
Auto Neg/En FC: Enables autonegotiation between 10 and 100 Mbps  
and between half-duplex and full-duplex modes, enables flow control  
6
7
8
9
100 FD/En FC: Selects 100 Mbps full-duplex, enables flow control  
100 HD/En FC: Selects 100 Mbps half-duplex, enables flow control  
10 FD/En FC: Selects 10 Mbps full-duplex, enables flow control  
10 HD/En FC: Selects 10 Mbps half-duplex, enables flow control  
NOTE: Switch positions 0-4 disable flow control. Positions 5-9 enable flow control.  
C2626M (2/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
 
NOTE: TX Mode configuration must be set when the module is powered off. If you wish to change  
a TX Mode switch setting after the module has been powered on, power off the module, change the  
TX Mode switch setting, and then power on the module again.  
MOUNTING  
The SX8205R module can be mounted into a rack or can be used as a stand-alone module. As a stand-  
alone module, the unit can be placed on a desktop or can be mounted to a wall.  
NOTE: As a matter of convenience, it is recommended that you set the modes of operation for each  
10BASE-T/100-BASE-TX port—if required—before mounting the SX8205R module into a rack or onto  
a wall. For information about setting the port modes of operation, refer to Setting 10BASE-T/  
MOUNTING THE SX8205R MODULE INTO A RACK  
The SX8205R module can be installed into an RK5000 Series rack mount chassis, which can be  
mounted into an industry-standard 19-inch (48.26 cm) equipment rack. The RK5000 Series rack mount  
chassis includes the following models:  
RK5000PS-3U and RK5000-3U: Designed to accommodate fiber optic modules as follows:  
The RK5000PS-3U rack mount chassis provides 12 single-width module slots and a  
power supply.  
The RK5000-3U rack mount chassis provides 14 single-width module slots (a power  
supply is not included). Power to the modules can be supplied using the optional  
external power supply (EPS5000-120).  
For additional information, refer to the RK5000PS-3U/RK5000-3U Fiber Rack Mount Chassis  
Installation manual.  
RK5000PS-5U: Designed to accommodate Enduramodules but can also accommodate fiber  
optic modules and the SX8205R module with the use of the appropriate adapter kit. The  
RK5001-1UEXP adapter kit is required for installation of the SX8205R module into the  
RK5000PS-5U chassis.  
MOUNTING THE SX8205R MODULE TO A WALL  
The SX8205R module can be mounted to a wall in the following ways:  
Using the supplied wall clip for attachment of a single module to a wall. For installation  
Using the optional WM5001 wall mount kits, which are designed for mounting of single-width  
fiber optic modules. The WM5001-3U base kit allows mounting of a single module to a wall.  
The WM5001-3UEXP expansion kit allows mounting of an additional module. It is  
recommended that a maximum of three expansion kits be used with the base kit, allowing a  
maximum of four single-width modules to be mounted to a wall.  
NOTE: The WM5001 wall mount kits can be used with the WM5002 wall mount kits, which are  
designed for mounting of double-width fiber optic modules. If mounting a mix of single-width  
and double-width modules is desired, it is recommended that a maximum of two single-width  
modules and one double-width module be mounted in combination with one another.  
For mounting instructions using the wall mount kits, refer to the WM5000 Series Wall Mount  
Kit Installation manual.  
12  
C2626M (2/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Mounting the SX8205R Module Using the Wall Clip  
NOTE: Before mounting the SX8205R module to a wall, ensure that there is adequate space at both  
ends for viewing the front-panel Power LED and for making the various rear-panel cable connections.  
To attach the SX8205R module to a wall using the supplied wall clip, refer to Figure 5 and do the  
following:  
1. Using the two vertical or horizontal wall-mounting holes, attach the wall clip to a wall using  
two screws (not provided).  
2. Slide the module into the clip until the two holes on the bottom of the module align with the  
two holes on the lower flange of the clip.  
3. Attach the module to the clip using the two Phillips pan head screws provided for the clip.  
UPPER  
FLANGE  
VERTICAL  
MOUNTING HOLE (2)  
HORIZONTAL  
MOUNTING HOLE (2)  
LOWER  
FLANGE  
SCREW, PHILLIPS  
PAN HEAD WITH  
LOCK WASHER (2)  
WALL CLIP  
Figure 5. Mounting the SX8205R Module Using the Wall Clip  
C2626M (2/07)  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CONNECTIONS  
Connections to the SX8205R module are made on the rear panel of the module (refer to Figure 6).  
POWER/ALARM CONNECTION  
FOR RACK-MOUNTED MODULE  
POWER CONNECTION  
FOR STAND-ALONE MODULE  
10/100 NETWORK CABLE  
10/100 NETWORK CABLE  
10/100 NETWORK CABLE  
10/100 NETWORK CABLE  
10/100 NETWORK CABLE  
Figure 6. SX8205R Module Connections  
As illustrated in Figure 6, SX8205R module connections consist of the following:  
Power connection  
NOTES:  
A 12 VDC or 24 VAC power supply can be used to power the module when used as a  
stand-alone unit. A 12 VDC power supply is provided. If a 24 VAC power supply is used,  
the power supply must be a Listed Direct Plug-In Power Unit marked as Class 2 and  
rated as 24 VAC, 0.50 A (minimum output).  
In extreme temperature conditions, it is recommended that an industrial-rated outdoor  
power supply such as the Pelco WCS1-4 power supply be used.  
10BASE-T/100BASE-TX connections  
NOTES:  
Use Cat5e or a higher category of cable to connect to a 10BASE-T/100BASE-TX port.  
Cable length must not exceed 328 feet (100 meters).  
The 10BASE-T/100BASE-TX ports are auto MDI/MDI-X ports; therefore, either a  
straight-through or crossover cable can be used. The ports automatically detect the  
cable type that is used. Refer to Appendix. RJ-45 Connector Pinouts on page 22 for  
pinout information.  
14  
C2626M (2/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Troubleshooting  
LED indicators on the front and rear panels of the SX8205R module allow you to monitor operational  
status:  
The Power LED (Pelco badge) on the front panel (refer to Figure 2) allows you to monitor  
operating power. Refer to Table B for information about the Power LED and associated  
troubleshooting guidelines.  
LED indicators on the rear panel (refer to Figure 3) allow you to monitor RJ-45 10BASE-T/  
100BASE-TX port status. Refer to Table C for information about the rear-panel indicators and  
associated troubleshooting guidelines.  
Table B. Troubleshooting with Front-Panel Indicator  
Indicator Color  
Meaning  
Possible Cause  
Corrective Action  
Power LED (Pelco badge)  
Blue  
Power is being  
applied to the  
module.  
No action required.  
Not lit  
Power is not being  
applied to the  
module.  
Power connection is faulty. Check power connection.  
If module is rack mounted,  
reseat module or power  
supply as necessary.  
Power supply has failed.  
Replace power supply.  
Loss of power occurs due to Check circuit breakers, fuses,  
tripped circuit breakers, or electrical service as  
blown fuses, or faulty elec- necessary.  
trical service.  
C2626M (2/07)  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Table C. Troubleshooting with Rear-Panel Indicators  
Meaning Possible Cause Corrective Action  
RJ-45 10BASE-T/100BASE-TX Port Status LED - Left (Link/Activity)  
Indicator Color  
Amber  
A 10BASE-T link is  
established.  
If 10BASE-T operation is  
desired, no action is required.  
If 10BASE-T operation is not  
desired, refer to Setting  
10BASE-T/100BASE-TX Port  
page 10 for information.  
Flashing amber  
Data activity is  
If 10BASE-T operation is  
desired, no action is required.  
If 10BASE-T operation is not  
desired, refer to Setting  
10BASE-T/100BASE-TX Port  
occurring on the  
10BASE-T link; data  
is being transmitted  
or received.  
page 10 for information.  
Green  
A 100BASE-TX link  
is established.  
If 100BASE-TX operation is  
desired, no action is required.  
If 100BASE-TX operation is not  
desired, refer to Setting  
10BASE-T/100BASE-TX Port  
page 10 for information.  
Flashing green  
Data activity is  
If 100BASE-TX operation is  
desired, no action is required.  
If 100BASE-TX operation is not  
desired, refer to Setting  
10BASE-T/100BASE-TX Port  
occurring on the  
100BASE-TX link;  
data is being trans-  
mitted or received.  
page 10 for information.  
(Continued on next page)  
16  
C2626M (2/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table C. Troubleshooting with Rear-Panel Indicators (Continued)  
Meaning Possible Cause Corrective Action  
RJ-45 10BASE-T/100BASE-TX Port Status LED - Left (Link/Activity) (Continued)  
Indicator Color  
Not lit  
A 10BASE-T or  
100BASE-TX link  
cannot be  
A problem may exist with  
the cable:  
Do any of the following as  
applicable:  
Cable is not connected  
to the module or to the  
10BASE-T/100BASE-TX  
compatible device.  
Connect the cable.  
established.  
Replace the cable. Use  
Cat5e or higher cable.  
Ensure that cable is proper  
length. Cable length must  
not exceed  
Cable is defective.  
Cable is not the proper  
cable type.  
328 feet (100 meters).  
Cable is not the proper  
length.  
Device connected to the  
Power on the device connected  
module is not powered on. to the module.  
Duplex mode setting (half- Set the duplex mode setting on  
duplex or full-duplex) does modules to match one another  
not match the duplex mode (autonegotiation or forced half-  
setting of the remote  
module.  
duplex or full-duplex). Refer to  
Setting 10BASE-T/  
information.  
Port on module is defective. Replace the module.  
(Continued on next page)  
C2626M (2/07)  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table C. Troubleshooting with Rear-Panel Indicators (Continued)  
Meaning Possible Cause Corrective Action  
RJ-45 10BASE-T/100BASE-TX Port Status LED - Right (Duplex/Collision)  
Indicator Color  
Amber  
Port is set to  
10BASE-T full-  
duplex mode.  
If 10BASE-T full-duplex  
operation is desired, no action  
is required. If 10BASE-T full-  
duplex operation is not  
desired, refer to Setting  
10BASE-T/100BASE-TX Port  
page 10 for information.  
Flashing amber  
Port is set to  
Normal or excessive colli-  
If a normal collision occurs, no  
10BASE-T half-  
duplex mode and  
network collision  
has occurred.*  
sions occur on a half-duplex action is required.  
link.* If a problem with the network  
exists due to excessive colli-  
sions, do any of the following  
as appropriate:  
If half-duplex mode is not  
required, set the TX Mode  
switch to full-duplex mode  
by means of autonegotia-  
tion or by forcing the mode  
information).  
If half-duplex mode is  
required, do any of the  
following as applicable:  
Replace network cable  
if it is defective or if it is  
not the proper cable  
type. Use Cat5e or  
higher cable.  
Ensure that cable is  
proper length. Cable  
length must not exceed  
328 feet (100 meters).  
Replace the network  
interface card (NIC) if it  
is defective or if it is  
incompatible.  
Segment the network.  
(Continued on next page)  
18  
C2626M (2/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table C. Troubleshooting with Rear-Panel Indicators (Continued)  
Meaning Possible Cause Corrective Action  
RJ-45 10BASE-T/100BASE-TX Port Status LED - Right (Duplex/Collision) (Continued)  
Indicator Color  
Green  
Port is set to  
100BASE-TX full-  
duplex mode.  
If 100BASE-TX full-duplex  
operation is desired, no action  
is required. If 100BASE-TX full-  
duplex operation is not  
desired, refer to Setting  
10BASE-T/100BASE-TX Port  
page 10 for information.  
Flashing green  
Port is set to  
Normal or excessive colli-  
If a normal collision occurs, no  
100BASE-TX half-  
duplex mode and  
network collision  
has occurred.*  
sions occur on a half-duplex action is required.  
link.* If a problem with the network  
exists due to excessive  
collisions, do any of the  
following as appropriate:  
If half-duplex mode is not  
required, set the TX Mode  
switch to full-duplex mode  
by means of autonegotia-  
tion or by forcing the mode  
information).  
If half-duplex mode is  
required, do any of the  
following as applicable:  
Replace cable if it is  
defective or if it is not  
the proper cable type.  
Use Cat5e or higher  
cable.  
Ensure that cable is the  
proper length. Cable  
length must not exceed  
328 feet (100 meters).  
Replace the network  
interface card (NIC) if it  
is defective or if it is  
incompatible.  
Segment the network.  
(Continued on next page)  
C2626M (2/07)  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table C. Troubleshooting with Rear-Panel Indicators (Continued)  
Meaning Possible Cause Corrective Action  
RJ-45 10BASE-T/100BASE-TX Port Status LED - Right (Duplex/Collision) (Continued)  
Indicator Color  
Not lit  
Port is set to  
If 10BASE-T half-duplex  
operation is desired, no action  
is required. If 10BASE-T half-  
duplex operation is not  
desired, refer to Setting  
10BASE-T/100BASE-TX Port  
10BASE-T half-  
duplex mode and no  
collisions are  
detected.*  
page 10 for information.  
*A collision is a normal event on a half-duplex Ethernet link. A collision occurs when two or more devices,  
referred to as stations, attempt to transmit at the same time on a shared physical medium.  
Ethernet uses the CSMA/CD (Carrier Sense Multiple Access/Collision Detect) media access method by  
which two or more stations share a common transmission medium. Using CSMA/CD, a station monitors  
the medium and transmits a message in bit-serial form when it senses that no other station is  
transmitting. If, after initiating a transmission, the message collides with that of another station, each  
transmitting station then intentionally transmits for an additional predefined period to ensure  
propagation of the collision throughout the system. To avoid another collision, each station waits a  
random amount of time (backoff) before attempting to transmit again.  
Excessive collisions occur when retransmission of a frame fails after 16 consecutive times and the frame  
is dropped. Excessive collisions may indicate that the network is becoming congested.  
20  
C2626M (2/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
PERFORMANCE  
Switch Type  
Unmanaged Layer 2  
Switch Method  
Switch Fabric  
Data Rate  
Store and forward  
Non-head-of-line blocking  
10/100 Mbps  
Compliance  
Interface  
IEEE 802.3, 802.3u, 802.3x  
Auto MDI/MDI-X  
Operating Mode  
Address Table Size  
Quality of Service  
Full-duplex or half-duplex  
1,024 MAC address entries with automatic learning and aging  
IEEE 802.1p priority, tag-based, 4 queues per port,  
weighted fair queuing scheduling  
Maximum Frame Size  
Untagged Ethernet frames up to 1,518 bytes  
Tagged Ethernet frames up to 1,522 bytes  
GENERAL  
Operating Temperature  
Input Power Requirements  
LED Indicators  
-40° to 167°F (-40° to 75°C)  
12 VDC or 24 VAC, 0.50 A  
Power  
10BASE-T/100BASE-TX port status (2 LEDs per port:  
link/activity and speed, duplex/collision and speed)  
8.75" D x 1.08" W x 4.81" H  
Dimensions  
Unit Weight  
(22.23 x 2.74 x 12.22 cm)  
1.6 lb (0.73 kg)  
MECHANICAL  
Connectors  
Rack Power/Alarm  
Stand-Alone Power  
Electrical  
1, 4-pin connector  
1, 2-pin connector, screw terminal  
5, RJ-45, 10BASE-T/100BASE-TX  
C2626M (2/07)  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Appendix. RJ-45 Connector Pinouts  
Figure 7 illustrates RJ-45 MDI/MDI-X connector pinouts.  
MDI (NORMAL MODE)  
MDI-X (CROSSED MODE)  
8
8
7
6
5
4
3
2
1
7
6
5
4
3
2
1
TX-  
RX-  
TX+  
RX-  
RX+  
RX+  
TX-  
TX+  
Figure 7. RJ-45 MDI/MDI-X Connector Pinouts  
Table D summarizes RJ-45 MDI/MDI-X connector pinouts.  
Table D. RJ-45 MDI/MDI-X Connector Pinouts  
MDI  
MDI-X  
Pin Number (Normal Mode) (Crossed Mode)  
1
2
3
4
5
6
7
8
RX+  
TX+  
RX-  
TX-  
TX+  
RX+  
Not used  
Not used  
TX-  
Not used  
Not used  
RX-  
Not used  
Not used  
Not used  
Not used  
The materials used in the manufacture of this document and its components are compliant to the  
requirements of Directive 2002/95/EC.  
This equipment contains electrical or electronic components that must be recycled properly to  
comply with Directive 2002/96/EC of the European Union regarding the disposal of waste  
electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling  
this equipment.  
22  
C2626M (2/07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
PRODUCT WARRANTY AND RETURN INFORMATION  
WARRANTY  
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of  
shipment.  
Exceptions to this warranty are as noted below:  
Five years on fiber optic products and TW3000 Series unshielded twisted pair transmission products.  
Three years on Spectra® IV products.  
Three years on Genex® Series products (multiplexers, server, and keyboard).  
Three years on Camclosure® and fixed camera models, except the CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-  
2X camera models, which have a five-year warranty.  
Three years on PMCL200/300/400 Series LCD monitors.  
Two years on standard motorized or fixed focal length lenses.  
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed dome products.  
Two years on Spectra III, Esprit®, ExSite, and PS20 scanners, including when used in continuous motion applications.  
Two years on Esprit and WW5700 Series window wiper (excluding wiper blades).  
Two years (except lamp and color wheel) on Digital Light Processing (DLP®) displays. The lamp and color wheel will be covered for a period of  
90 days. The air filter is not covered under warranty.  
Eighteen months on DX Series digital video recorders, NVR300 Series network video recorders, and EnduraSeries distributed network-based video  
products.  
One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.  
Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes).  
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight  
prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this  
warranty.  
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelcos  
liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products  
shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential  
damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.  
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state  
to state.  
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and  
provide the following information:  
1. Model and serial number  
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number  
3. Details of the defect or problem  
If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written  
explanation with the product when returned.  
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.  
RETURNS  
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization  
number (CA number if returned for credit, and RA number if returned for repair).  
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.  
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate  
address below.  
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:  
Service Department  
Pelco  
3500 Pelco Way  
Clovis, CA 93612-5699  
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the  
following:  
If the goods are to be sent by a COURIER SERVICE, send the goods to:  
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:  
Pelco  
Pelco c/o Expeditors  
3500 Pelco Way  
Clovis, CA 93612-5699 USA  
473 Eccles Avenue  
South San Francisco, CA 94080 USA  
Phone: 650-737-1700  
Fax: 650-737-0933  
REVISION HISTORY  
Manual #  
Date Comments  
C2626M-BETA 10/06 Beta version.  
C2626M 2/07 Official release.  
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco.  
Endura, ExSite, and Spectra III are trademarks of Pelco.  
DLP is a registered trademark of Texas Instruments, Inc.  
©Copyright 2007, Pelco.  
All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
Worldwide Headquarters  
3500 Pelco Way  
Clovis, California 93612 USA  
USA & Canada  
Tel: 800/289-9100  
Fax: 800/289-9150  
International  
Tel: 1-559/292-1981  
Fax: 1-559/348-1120  
ISO9001  
Australia Canada Finland France Germany Italy Macau The Netherlands Russia Singapore  
|
|
|
|
|
|
|
|
|
South Africa Spain Sweden United Arab Emirates United Kingdom United States  
|
|
|
|
|
Download from Www.Somanuals.com. All Manuals Search And Download.  

Peavey Music Mixer PA 200 User Manual
Peavey Stereo Amplifier CA6 X User Manual
Peerless Industries TV Mount PM 13 User Manual
Perception Digital CD Player PD 450 01 User Manual
Philips Digital Photo Frame 7FF1CMI 37 User Manual
Philips DVD Recorder LX7500R User Manual
Pioneer Portable DVD Player AVH X6500DVD User Manual
Polycom Cell Phone KH 150 SE User Manual
Powerware Power Supply 9315s User Manual
PYLE Audio Automobile Accessories PNVS4 User Manual