MS500 Series
Manual Switchers
Installation/
Operation Manual
C820M-D (1/01)
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150
International Customers: Tel +1 (559) 292-1981 or FAX +1 (559) 348-1120
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by qualified service personnel and
conform to all local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X ,6 or 6P
enclosure, it is designed for indoor use only and it must not be installed where
exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
4. After replacement/repair of this unit’s electrical components, conduct a resistance
measurement between line and exposed parts to verify the exposed parts have not
been connected to line circuitry.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous
voltage constituting a risk of electric shock
is present within this unit.
C A U T I O N :
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
This symbol indicates that there are
important operating and maintenance
instructions in the literature accompanying
this unit.
Please thoroughly familiarize yourself with the information in this manual prior to installation
and operation.
Pelco Manual C820M-D (1/01)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
DESCRIPTION
The MS500 Series provides an inexpensive and reliable method of switching 4 to 18 inputs
to a single monitor output using interlocked manual pushbuttons. Included in this series is
the MS540 switcher with two monitor outputs and the capacity to switch up to 40 inputs with
a 14 pushbutton panel.
The MS500 Series Switchers are designed for either looping or terminating operation,
depending on the model.
MODELS
Terminating
MS504DT
4 inputs (UL)
MS508DT
8 inputs (UL)
MS512DT
12 inputs (UL)
MS518DT
18 inputs (UL)
MS540DT
40 inputs (UL)
MS504GDT
MS508GDT
MS512GDT
MS512GDT/220
MS518GDT
4 inputs, illuminated buttons, 120 VAC (UL)
Same as MS504GDT, 8 inputs (UL)
Same as MS504GDT, 12 inputs (UL)
Same as MS512GDT except 230 VAC
Same as MS504GDT, 18 inputs (UL)
Terminating With Audio Follow
MS504AF
MS508AF
MS512AF
MS518AF
4 inputs (UL)
8 inputs (UL)
12 inputs (UL)
18 inputs (UL)
Terminating With Balanced Audio Follow
MS504BAF
MS508BAF
MS512BAF
4 inputs (UL)
8 inputs (UL)
12 inputs (UL)
Looping
MS504LDT
MS508LDT
MS512LDT
MS518LDT
MS540LDT
MS540LDT/220
MS504GLDT
4 inputs (UL)
8 inputs (UL)
12 inputs (UL)
18 inputs (UL)
40 inputs, 2 monitor outputs 120 VAC (UL)
Same as MS540LDT except 230 VAC
4 inputs, illuminated buttons, 120 VAC input (UL)
MS504GLDT/220 Same as MS504GLDT except 230 VAC
MS508GLDT
MS512GLDT
Same as MS504GLDT, 8 inputs (UL)
Same as MS504GLDT, 12 inputs (UL)
MS512GLDT/220 Same as MS512GLDT except 230 VAC
MS518GLDT Same as MS504GLDT, 18 inputs (UL)
Looping With Audio Follow
MS504AFL
MS508AFL
MS512AFL
MS518AFL
4 inputs (UL)
8 inputs (UL)
12 inputs (UL)
18 inputs (UL)
Looping With Balanced Audio Follow
MS504BAFL
MS508BAFL
MS512BAFL
4 inputs (UL)
8 inputs (UL)
12 input (UL)INSTALLATION
4
Pelco Manual C820M-D (1/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
1. Place the unit on a flat surface, or install it in an equipment rack using the appropriate
NOTE: For the maximum
recommended cable dis-
tances refer to the installa-
tion manuals supplied with
equipment (camera, lens
and monitor) to be used with
the switcher.
rack-mount kit.
2. Refer to Figures 1 - 6 and select the desired configuration for your installation. Make
all equipment connections as illustrated in the drawings. Refer to Table A for the type
of coaxial cable to use.
3. Plug in the power cord. The switcher will begin operating.
Table A. Video Coaxial Cable Requirements
Cable Type*
Maximum Distance
RG59/U
RG6/U
RG11/U
750 ft (229 m)
1,000 ft (305 m)
1,500 ft (457 m)
* Minimum cable requirements:
75 ohms impedance
All-copper center conductor
All-copper braided shield with 95% braid coverage
TERMINATING SWITCHERS
When using non-looping switchers, the monitor should be terminated unless the looping
output, if available, on the monitor is used. (Refer to Figures 1 and 2.)
TERMINATE
MONITOR
(SWITCH IN THE
75Ω POSITION)
CAMERA
MON
4
3
2
1
MS504DT (REAR VIEW)
AC INPUT
Figure 1. MS500 Series Switchers - Terminating Configuration
TERMINATE
MONITOR
(SWITCH IN THE
75Ω POSITION)
COAXITRON
TRANSMITTER
TERMINATE LOOPING
OUTPUT AT 75Ω
CAMERA
MON
4
3
2
1
AC INPUT
MS504AF (REAR VIEW)
Figure 2. MS500 Series Switchers - Terminating Configuration with Coaxitron® Transmitter
Pelco Manual C820M-D (1/01)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
LOOPING SWITCHERS
Use coaxial cable to connect the input and looping video cables to the appropriate input
connectors. Connect the monitor(s) to the monitor output. (Refer to Figures 3 and 4.)
IMPORTANT: Looping
switchers do not have inter-
nal termination. Inputs must
be terminated at 75 ohms by
other equipment in the
system.
TERMINATE
MONITOR
(SWITCH IN THE
75Ω POSITION)
UN-TERMINATED
MONITOR
(SWITCH IN THE
HI-Z POSITION)
CAMERA
MON
4
3
2
1
MS504LDT (REAR VIEW)
MS504DT (REAR VIEW)
AC INPUT
CAMERA
MON
4
3
2
1
AC INPUT
Figure 3. MS500 Series Switchers - Looping Configuration
TERMINATE
MONITOR
(SWITCH IN THE
75Ω POSITION)
COAXITRON
TRANSMITTER
UNTERMINATED
TRANSMITTER
CAMERA
MS504LDT
(REAR VIEW)
MON
4
3
2
1
TERMINATE
MONITOR
(SWITCH IN THE
75Ω POSITION)
AC INPUT
COAXITRON
TRANSMITTER
CAMERA
TERMINATE LOOPING
OUTPUT AT 75Ω
MON
MS504DT
(REAR VIEW)
4
3
2
1
AC INPUT
Figure 4. MS500 Series Switchers - Looping Configuration with Coaxitron Transmitter
6
Pelco Manual C820M-D (1/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
SWITCHERS WITH AUDIO FOLLOW
NOTE: Configuration does
not permit two-way commu-
nication. Microphones or
speakers, etc., can be in-
stalled at the camera site.
MS500 Series models with “AF” in the suffix have a connection for an audio signal source.
Using appropriate cable with compatible connectors, connect audio signal sources to RCA
jack (refer to Figure 5).
TERMINATE
MONITOR
(SWITCH IN THE
75Ω POSITION)
AUDIO IN/OUT
CAMERA
AUDIO IN/OUT
MON
4
3
2
1
VIDEO OUT
MS504AF (REAR VIEW)
Figure 5. MS500 Series Switchers with Audio Follow
SWITCHERS WITH BALANCED AUDIO FOLLOW
NOTE: Configuration does
not permit two-way commu-
nication. Microphones or
speakers, etc., can be in-
stalled at the camera site.
MS500 Series models with “BAF” in the suffix have terminal block connections for a two-
conductor cable. This cable can be used for balanced audio follow or similar signals. (Refer
to Figure 6.)
TERMINATE
MONITOR
(SWITCH IN THE
75Ω POSITION)
AUDIO IN/OUT
AUDIO IN/OUT
VIDEO OUT
AUDIO
OUT
AUDIO IN
VIDEO IN
MON
1
1
2
3
4
A
B
A
B
A
B
A
B
A
B
4
3
2
1
MS504BAF (REAR VIEW)
Figure 6. MS500 Series Switchers with Balanced Audio Follow
Pelco Manual C820M-D (1/01)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
SWITCHERS WITH AMPLIFIED OUTPUT
The MS540DT and MS540LDT switchers provide both an amplified output (Monitor 1) and
a non-amplified output (Monitor 2). Most installations require the use of Monitor 2 output for
proper operations.
NOTE: Use Monitor 2 non-amplified output only when interfacing with the
MPT9000CZ/MPT9000PZ or KBD9000/KBD9000-X Coaxitron controls.
OPERATION
To operate the MS500 Series Switcher, plug in the power cord and press a camera button
to view video from the corresponding camera.
MAINTENANCE
Regularly scheduled maintenance is not required. However, maintenance may be required
in the following situations:
1. For switcher contacts that are not conducting properly, clean with a non-conducting
electrical contact spray cleaner especially made for that purpose. Remove cover for
access to the contacts and spray cleaner carefully into contacts from the rear.
2. To replace burned out bulbs in illuminated models, remove the switch cover from the
front of the unit and push the bulb upwards, then lift out. Replace with Pelco #LAP327.
IMPORTANT: Units plugged into electrical outlets should be unplugged
before spraying contacts.
8
Pelco Manual C820M-D (1/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
AUDIO FOLLOW OPTION
CON 3505
RCA
JAX
AUDIO
OUTPUT
AUDIO
INPUTS
N
2
1
T1
18 V.A.C.
BLK
1
BLK
I1
I2
RED
IN
F1
BLK/YEL
BLK/GRN
GRN
GRN/YEL
YEL
AC
INPUT
1/16 AMP
RN
75Ω
GRY
R2
75Ω
R2
75Ω
BLK/RED
BRN
TYPICAL
2
-FOR 220 VAC INPUT ADD JUMPER TO 2 & 3
REMOVE JUMPER FROM 1 & 3, 2 & 4
N
CONNECTION
FOR
1
VIDEO
OUTPUT
VIDEO
INPUTS
LOOPING
DELETE TERMINATION RESISITORS 75 OHM FOR LOOPING
Figure 7. Schematic for 4-18 Position Manual Switchers
75 TYP.
00-09
TYPICAL
CONNECTION
FOR LOOPING
10-19
00
01
02*
03*
*30-39
MON 2
VIDEO
OUTPUT
T 1
*20-29
YEL
IN 4005
GRN/YEL
56 2 W
1
BLK
GRN
RED
IN 4740
50
25 V
25
1 K
500
50 V
F 1
15 V
47 K
220
2 N
BLU
GRY
2
3
BLK/YEL
BLK/GRN
3638
1/16 AMP
2N
3565
75
2000
16 V
IN 4005
100
100
BRN
22 PF
MON I
BLK/RED
4
27 K
AMPLIFIED
VIDEO OUPUT
680
NOTES:
* AS REQUIRED
- FOR LOOPING, DELETE RESISTORS 75 OHM
- FOR 110 VAC INPUT JUMPER 1 & 3; 2 & 4
- FOR 220 VAC INPUT JUMPER 2 & 3
A C
INPUT
Figure 8. Schematic for 40 Position Manual swithcers
Pelco Manual C820M-D (1/01)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS
VIDEO
Inputs:
4, 8, 12, or 40 as indicated by the last two digits of the model
number.
Video Connectors:
BNC
Audio Connectors:
AF Switchers
BAF Switchers
1/8-inch RCA phone jack
Terminal block
Termination:
Terminated or Non-looping Switchers
Input
75-ohm internal termination
Output
75-ohm source termination
Looping Switchers
Input
Output
High impedance looping
High impedance looping
ELECTRICAL
(Models MS500G, MS500GL, MS540DT, and MS540LDT)
Input Voltage:
120 VAC, 50/60 Hz or 230 VAC, 50 Hz
Power
Requirement:
.095 amp (11 vA)
Fuse:
3 AG 1/16 amp slo-blow
3-wire grounded #18 AWG
Power Cord:
(Models MS540DT and MS540LDT Only)
Output Amplifier:
Gain:
One amplified output and one non-amplified output for use with
MPT9000CZ/MPT9000PZ (Coaxitron® System).
Unity
Frequency
Response:
Flat within ±1 dB to 10 MHz
Max. Signal
Level:
2 Vp-p
10
Pelco Manual C820M-D (1/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
GENERAL
Switching:
Interlocked manual pushbuttons
Construction:
Cover
Chassis
Panel
Steel, black polyester powder coat
Steel, zinc plated
Aluminum, black polyester powder coat
Environment:
32° to 120°F (0° to 48.89°C)
Dimensions
MS504 Series
(except AFL,
BAF, and BAF
models):
1.75 (H) x 5.3 (W) x 9.3 (L) inches
(4.45 cm x 13.46 cm x 23.62 cm)
MS504AFL,
MS504BAF,
MS504BAFL, and
MS508 Series
(except AFL
model):
1.75 (H) x 14.3 (W) x 9.3 (L) inches
(4.45 cm x 36.32 cm x 23.62 cm)
MS508AFL,
MS512 Series,
MS518 Series, and
MS540DT (except
MS518AFL and
MS540LDT):
1.75 (H) x 17.12 (W) x 9.3 (L) inches
(4.45 cm x 43.48 cm x 23.62 cm)
MS518AFL and
MS540LDT:
3.50 (H) x 17.12 (W) x 9.3 (L) inches
(8.89 cm x 43.48 cm x 23.62 cm)
(Design and product specifications subject to change without notice.)
Pelco Manual C820M-D (1/01)
11
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or
workmanship for a period of one year after the date of shipment.
If
a
warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following
information:
1. Model and serial number
Exceptions to this warranty are as noted below:
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
•
•
•
Five years on FT/FR8000 Series fiber optic products.
Three years on Genex® Series products (multiplexers, server, and keyboard).
If there is a dispute regarding the warranty of a product which does not fall under the
warranty conditions stated above, please include a written explanation with the product
when returned.
Three years on Camclosure® and fixed camera models, except the CC3701H-2,
CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models,
which have a five-year warranty.
Method of return shipment shall be the same or equal to the method by which the item was
received by Pelco.
•
•
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series
fixed dome products.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at
(800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned
for credit, and RA number if returned for repair).
•
Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, including when used in
continuous motion applications.
•
•
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing
charge.
Eighteen months on DX Series digital video recorders, NVR300 Series network video
recorders, and Endura™ Series distributed network-based video products.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA
number and freight should be prepaid. Ship to the appropriate address below.
•
•
One year (except video heads) on video cassette recorders (VCRs). Video heads will be
covered for a period of six months.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department
Pelco
Six months on all pan and tilts, scanners or preset lenses used in continuous motion
applications (that is, preset scan, tour and auto scan modes).
3500 Pelco Way
Clovis, CA 93612-5699
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco
shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,
California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident
are not covered under this warranty.
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are
instructed to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from
the specific use or application made of the Products. Pelco’s liability for any claim, whether
based on breach of contract, negligence, infringement of any rights of any party or product
liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for
such Products. In no event will Pelco be liable for any special, incidental or consequential
damages (including loss of use, loss of profit and claims of third parties) however caused,
whether by the negligence of Pelco or otherwise.
3500 Pelco Way
Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors
473 Eccles Avenue
The above warranty provides the Dealer with specific legal rights. The Dealer may also have
additional rights, which are subject to variation from state to state.
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
REVISION HISTORY
Manual #
C820M
C820M-A
C820M-B
C820M-C
C820M-D
Date
3/88
9/90
6/92
10/97
1/01
Comments
Original version.
Added to Warning Section for UL compliance.
Revised to cover all MS500 Series models. Added DT200 to Options section.
Revised Figures 1 and 2. Put into new format.
Added illustrations for terminated and looping configurations with a Coaxitron transmitter. Updated manual to new format.
® Pelco, the Pelco logo, Spectra, Genex, Legacy, Coaxitron, and PelcoVision are registered trademarks of Pelco.
™ Esprit and Camclosure are trademarks of Pelco.
© Copyright 2001, Pelco.
All rights reserved.
12
Pelco Manual C820M-D (1/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
|