Pelco Switch MS504AFL User Manual

MS500 Series  
Manual Switchers  
Installation/  
Operation Manual  
C820M-D (1/01)  
Pelco • 3500 Pelco Way, Clovis • CA 93612-5699 USA • www.pelco.com  
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150  
International Customers: Tel +1 (559) 292-1981 or FAX +1 (559) 348-1120  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFEGUARDS AND WARNINGS  
Prior to installation and use of this product, the following WARNINGS should be observed.  
1. Installation and servicing should only be done by qualified service personnel and  
conform to all local codes.  
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X ,6 or 6P  
enclosure, it is designed for indoor use only and it must not be installed where  
exposed to rain and moisture.  
3. Only use replacement parts recommended by Pelco.  
4. After replacement/repair of this unit’s electrical components, conduct a resistance  
measurement between line and exposed parts to verify the exposed parts have not  
been connected to line circuitry.  
The product and/or manual may bear the following marks:  
This symbol indicates that dangerous  
voltage constituting a risk of electric shock  
is present within this unit.  
C A U T I O N :  
RISK OF ELECTRIC SHOCK.  
DO NOT OPEN.  
This symbol indicates that there are  
important operating and maintenance  
instructions in the literature accompanying  
this unit.  
Please thoroughly familiarize yourself with the information in this manual prior to installation  
and operation.  
Pelco Manual C820M-D (1/01)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESCRIPTION  
The MS500 Series provides an inexpensive and reliable method of switching 4 to 18 inputs  
to a single monitor output using interlocked manual pushbuttons. Included in this series is  
the MS540 switcher with two monitor outputs and the capacity to switch up to 40 inputs with  
a 14 pushbutton panel.  
The MS500 Series Switchers are designed for either looping or terminating operation,  
depending on the model.  
MODELS  
Terminating  
MS504DT  
4 inputs (UL)  
MS508DT  
8 inputs (UL)  
MS512DT  
12 inputs (UL)  
MS518DT  
18 inputs (UL)  
MS540DT  
40 inputs (UL)  
MS504GDT  
MS508GDT  
MS512GDT  
MS512GDT/220  
MS518GDT  
4 inputs, illuminated buttons, 120 VAC (UL)  
Same as MS504GDT, 8 inputs (UL)  
Same as MS504GDT, 12 inputs (UL)  
Same as MS512GDT except 230 VAC  
Same as MS504GDT, 18 inputs (UL)  
Terminating With Audio Follow  
MS504AF  
MS508AF  
MS512AF  
MS518AF  
4 inputs (UL)  
8 inputs (UL)  
12 inputs (UL)  
18 inputs (UL)  
Terminating With Balanced Audio Follow  
MS504BAF  
MS508BAF  
MS512BAF  
4 inputs (UL)  
8 inputs (UL)  
12 inputs (UL)  
Looping  
MS504LDT  
MS508LDT  
MS512LDT  
MS518LDT  
MS540LDT  
MS540LDT/220  
MS504GLDT  
4 inputs (UL)  
8 inputs (UL)  
12 inputs (UL)  
18 inputs (UL)  
40 inputs, 2 monitor outputs 120 VAC (UL)  
Same as MS540LDT except 230 VAC  
4 inputs, illuminated buttons, 120 VAC input (UL)  
MS504GLDT/220 Same as MS504GLDT except 230 VAC  
MS508GLDT  
MS512GLDT  
Same as MS504GLDT, 8 inputs (UL)  
Same as MS504GLDT, 12 inputs (UL)  
MS512GLDT/220 Same as MS512GLDT except 230 VAC  
MS518GLDT Same as MS504GLDT, 18 inputs (UL)  
Looping With Audio Follow  
MS504AFL  
MS508AFL  
MS512AFL  
MS518AFL  
4 inputs (UL)  
8 inputs (UL)  
12 inputs (UL)  
18 inputs (UL)  
Looping With Balanced Audio Follow  
MS504BAFL  
MS508BAFL  
MS512BAFL  
4 inputs (UL)  
8 inputs (UL)  
12 input (UL)INSTALLATION  
4
Pelco Manual C820M-D (1/01)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
1. Place the unit on a flat surface, or install it in an equipment rack using the appropriate  
NOTE: For the maximum  
recommended cable dis-  
tances refer to the installa-  
tion manuals supplied with  
equipment (camera, lens  
and monitor) to be used with  
the switcher.  
rack-mount kit.  
2. Refer to Figures 1 - 6 and select the desired configuration for your installation. Make  
all equipment connections as illustrated in the drawings. Refer to Table A for the type  
of coaxial cable to use.  
3. Plug in the power cord. The switcher will begin operating.  
Table A. Video Coaxial Cable Requirements  
Cable Type*  
Maximum Distance  
RG59/U  
RG6/U  
RG11/U  
750 ft (229 m)  
1,000 ft (305 m)  
1,500 ft (457 m)  
* Minimum cable requirements:  
75 ohms impedance  
All-copper center conductor  
All-copper braided shield with 95% braid coverage  
TERMINATING SWITCHERS  
When using non-looping switchers, the monitor should be terminated unless the looping  
output, if available, on the monitor is used. (Refer to Figures 1 and 2.)  
TERMINATE  
MONITOR  
(SWITCH IN THE  
75POSITION)  
CAMERA  
MON  
4
3
2
1
MS504DT (REAR VIEW)  
AC INPUT  
Figure 1. MS500 Series Switchers - Terminating Configuration  
TERMINATE  
MONITOR  
(SWITCH IN THE  
75POSITION)  
COAXITRON  
TRANSMITTER  
TERMINATE LOOPING  
OUTPUT AT 75Ω  
CAMERA  
MON  
4
3
2
1
AC INPUT  
MS504AF (REAR VIEW)  
Figure 2. MS500 Series Switchers - Terminating Configuration with Coaxitron® Transmitter  
Pelco Manual C820M-D (1/01)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
LOOPING SWITCHERS  
Use coaxial cable to connect the input and looping video cables to the appropriate input  
connectors. Connect the monitor(s) to the monitor output. (Refer to Figures 3 and 4.)  
IMPORTANT: Looping  
switchers do not have inter-  
nal termination. Inputs must  
be terminated at 75 ohms by  
other equipment in the  
system.  
TERMINATE  
MONITOR  
(SWITCH IN THE  
75POSITION)  
UN-TERMINATED  
MONITOR  
(SWITCH IN THE  
HI-Z POSITION)  
CAMERA  
MON  
4
3
2
1
MS504LDT (REAR VIEW)  
MS504DT (REAR VIEW)  
AC INPUT  
CAMERA  
MON  
4
3
2
1
AC INPUT  
Figure 3. MS500 Series Switchers - Looping Configuration  
TERMINATE  
MONITOR  
(SWITCH IN THE  
75POSITION)  
COAXITRON  
TRANSMITTER  
UNTERMINATED  
TRANSMITTER  
CAMERA  
MS504LDT  
(REAR VIEW)  
MON  
4
3
2
1
TERMINATE  
MONITOR  
(SWITCH IN THE  
75POSITION)  
AC INPUT  
COAXITRON  
TRANSMITTER  
CAMERA  
TERMINATE LOOPING  
OUTPUT AT 75Ω  
MON  
MS504DT  
(REAR VIEW)  
4
3
2
1
AC INPUT  
Figure 4. MS500 Series Switchers - Looping Configuration with Coaxitron Transmitter  
6
Pelco Manual C820M-D (1/01)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SWITCHERS WITH AUDIO FOLLOW  
NOTE: Configuration does  
not permit two-way commu-  
nication. Microphones or  
speakers, etc., can be in-  
stalled at the camera site.  
MS500 Series models with “AF” in the suffix have a connection for an audio signal source.  
Using appropriate cable with compatible connectors, connect audio signal sources to RCA  
jack (refer to Figure 5).  
TERMINATE  
MONITOR  
(SWITCH IN THE  
75POSITION)  
AUDIO IN/OUT  
CAMERA  
AUDIO IN/OUT  
MON  
4
3
2
1
VIDEO OUT  
MS504AF (REAR VIEW)  
Figure 5. MS500 Series Switchers with Audio Follow  
SWITCHERS WITH BALANCED AUDIO FOLLOW  
NOTE: Configuration does  
not permit two-way commu-  
nication. Microphones or  
speakers, etc., can be in-  
stalled at the camera site.  
MS500 Series models with “BAF” in the suffix have terminal block connections for a two-  
conductor cable. This cable can be used for balanced audio follow or similar signals. (Refer  
to Figure 6.)  
TERMINATE  
MONITOR  
(SWITCH IN THE  
75POSITION)  
AUDIO IN/OUT  
AUDIO IN/OUT  
VIDEO OUT  
AUDIO  
OUT  
AUDIO IN  
VIDEO IN  
MON  
1
1
2
3
4
A
B
A
B
A
B
A
B
A
B
4
3
2
1
MS504BAF (REAR VIEW)  
Figure 6. MS500 Series Switchers with Balanced Audio Follow  
Pelco Manual C820M-D (1/01)  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
SWITCHERS WITH AMPLIFIED OUTPUT  
The MS540DT and MS540LDT switchers provide both an amplified output (Monitor 1) and  
a non-amplified output (Monitor 2). Most installations require the use of Monitor 2 output for  
proper operations.  
NOTE: Use Monitor 2 non-amplified output only when interfacing with the  
MPT9000CZ/MPT9000PZ or KBD9000/KBD9000-X Coaxitron controls.  
OPERATION  
To operate the MS500 Series Switcher, plug in the power cord and press a camera button  
to view video from the corresponding camera.  
MAINTENANCE  
Regularly scheduled maintenance is not required. However, maintenance may be required  
in the following situations:  
1. For switcher contacts that are not conducting properly, clean with a non-conducting  
electrical contact spray cleaner especially made for that purpose. Remove cover for  
access to the contacts and spray cleaner carefully into contacts from the rear.  
2. To replace burned out bulbs in illuminated models, remove the switch cover from the  
front of the unit and push the bulb upwards, then lift out. Replace with Pelco #LAP327.  
IMPORTANT: Units plugged into electrical outlets should be unplugged  
before spraying contacts.  
8
Pelco Manual C820M-D (1/01)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AUDIO FOLLOW OPTION  
CON 3505  
RCA  
JAX  
AUDIO  
OUTPUT  
AUDIO  
INPUTS  
N
2
1
T1  
18 V.A.C.  
BLK  
1
BLK  
I1  
I2  
RED  
IN  
F1  
BLK/YEL  
BLK/GRN  
GRN  
GRN/YEL  
YEL  
AC  
INPUT  
1/16 AMP  
RN  
75  
GRY  
R2  
75Ω  
R2  
75Ω  
BLK/RED  
BRN  
TYPICAL  
2
-FOR 220 VAC INPUT ADD JUMPER TO 2 & 3  
REMOVE JUMPER FROM 1 & 3, 2 & 4  
N
CONNECTION  
FOR  
1
VIDEO  
OUTPUT  
VIDEO  
INPUTS  
LOOPING  
DELETE TERMINATION RESISITORS 75 OHM FOR LOOPING  
Figure 7. Schematic for 4-18 Position Manual Switchers  
75 TYP.  
00-09  
TYPICAL  
CONNECTION  
FOR LOOPING  
10-19  
00  
01  
02*  
03*  
*30-39  
MON 2  
VIDEO  
OUTPUT  
T 1  
*20-29  
YEL  
IN 4005  
GRN/YEL  
56 2 W  
1
BLK  
GRN  
RED  
IN 4740  
50  
25 V  
25  
1 K  
500  
50 V  
F 1  
15 V  
47 K  
220  
2 N  
BLU  
GRY  
2
3
BLK/YEL  
BLK/GRN  
3638  
1/16 AMP  
2N  
3565  
75  
2000  
16 V  
IN 4005  
100  
100  
BRN  
22 PF  
MON I  
BLK/RED  
4
27 K  
AMPLIFIED  
VIDEO OUPUT  
680  
NOTES:  
* AS REQUIRED  
- FOR LOOPING, DELETE RESISTORS 75 OHM  
- FOR 110 VAC INPUT JUMPER 1 & 3; 2 & 4  
- FOR 220 VAC INPUT JUMPER 2 & 3  
A C  
INPUT  
Figure 8. Schematic for 40 Position Manual swithcers  
Pelco Manual C820M-D (1/01)  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
VIDEO  
Inputs:  
4, 8, 12, or 40 as indicated by the last two digits of the model  
number.  
Video Connectors:  
BNC  
Audio Connectors:  
AF Switchers  
BAF Switchers  
1/8-inch RCA phone jack  
Terminal block  
Termination:  
Terminated or Non-looping Switchers  
Input  
75-ohm internal termination  
Output  
75-ohm source termination  
Looping Switchers  
Input  
Output  
High impedance looping  
High impedance looping  
ELECTRICAL  
(Models MS500G, MS500GL, MS540DT, and MS540LDT)  
Input Voltage:  
120 VAC, 50/60 Hz or 230 VAC, 50 Hz  
Power  
Requirement:  
.095 amp (11 vA)  
Fuse:  
3 AG 1/16 amp slo-blow  
3-wire grounded #18 AWG  
Power Cord:  
(Models MS540DT and MS540LDT Only)  
Output Amplifier:  
Gain:  
One amplified output and one non-amplified output for use with  
MPT9000CZ/MPT9000PZ (Coaxitron® System).  
Unity  
Frequency  
Response:  
Flat within ±1 dB to 10 MHz  
Max. Signal  
Level:  
2 Vp-p  
10  
Pelco Manual C820M-D (1/01)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GENERAL  
Switching:  
Interlocked manual pushbuttons  
Construction:  
Cover  
Chassis  
Panel  
Steel, black polyester powder coat  
Steel, zinc plated  
Aluminum, black polyester powder coat  
Environment:  
32° to 120°F (0° to 48.89°C)  
Dimensions  
MS504 Series  
(except AFL,  
BAF, and BAF  
models):  
1.75 (H) x 5.3 (W) x 9.3 (L) inches  
(4.45 cm x 13.46 cm x 23.62 cm)  
MS504AFL,  
MS504BAF,  
MS504BAFL, and  
MS508 Series  
(except AFL  
model):  
1.75 (H) x 14.3 (W) x 9.3 (L) inches  
(4.45 cm x 36.32 cm x 23.62 cm)  
MS508AFL,  
MS512 Series,  
MS518 Series, and  
MS540DT (except  
MS518AFL and  
MS540LDT):  
1.75 (H) x 17.12 (W) x 9.3 (L) inches  
(4.45 cm x 43.48 cm x 23.62 cm)  
MS518AFL and  
MS540LDT:  
3.50 (H) x 17.12 (W) x 9.3 (L) inches  
(8.89 cm x 43.48 cm x 23.62 cm)  
(Design and product specifications subject to change without notice.)  
Pelco Manual C820M-D (1/01)  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRODUCT WARRANTY AND RETURN INFORMATION  
WARRANTY  
Pelco will repair or replace, without charge, any merchandise proved defective in material or  
workmanship for a period of one year after the date of shipment.  
If  
a
warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or  
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following  
information:  
1. Model and serial number  
Exceptions to this warranty are as noted below:  
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number  
3. Details of the defect or problem  
Five years on FT/FR8000 Series fiber optic products.  
Three years on Genex® Series products (multiplexers, server, and keyboard).  
If there is a dispute regarding the warranty of a product which does not fall under the  
warranty conditions stated above, please include a written explanation with the product  
when returned.  
Three years on Camclosure® and fixed camera models, except the CC3701H-2,  
CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models,  
which have a five-year warranty.  
Method of return shipment shall be the same or equal to the method by which the item was  
received by Pelco.  
Two years on standard motorized or fixed focal length lenses.  
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series  
fixed dome products.  
RETURNS  
In order to expedite parts returned to the factory for repair or credit, please call the factory at  
(800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned  
for credit, and RA number if returned for repair).  
Two years on Spectra®, Esprit®, ExSite, and PS20 scanners, including when used in  
continuous motion applications.  
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).  
All merchandise returned for credit may be subject to a 20% restocking and refurbishing  
charge.  
Eighteen months on DX Series digital video recorders, NVR300 Series network video  
recorders, and EnduraSeries distributed network-based video products.  
Goods returned for repair or credit should be clearly identified with the assigned CA or RA  
number and freight should be prepaid. Ship to the appropriate address below.  
One year (except video heads) on video cassette recorders (VCRs). Video heads will be  
covered for a period of six months.  
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:  
Service Department  
Pelco  
Six months on all pan and tilts, scanners or preset lenses used in continuous motion  
applications (that is, preset scan, tour and auto scan modes).  
3500 Pelco Way  
Clovis, CA 93612-5699  
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco  
shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,  
California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident  
are not covered under this warranty.  
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are  
instructed to return goods to the USA, you may do one of the following:  
If the goods are to be sent by a COURIER SERVICE, send the goods to:  
Pelco  
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from  
the specific use or application made of the Products. Pelcos liability for any claim, whether  
based on breach of contract, negligence, infringement of any rights of any party or product  
liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for  
such Products. In no event will Pelco be liable for any special, incidental or consequential  
damages (including loss of use, loss of profit and claims of third parties) however caused,  
whether by the negligence of Pelco or otherwise.  
3500 Pelco Way  
Clovis, CA 93612-5699 USA  
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:  
Pelco c/o Expeditors  
473 Eccles Avenue  
The above warranty provides the Dealer with specific legal rights. The Dealer may also have  
additional rights, which are subject to variation from state to state.  
South San Francisco, CA 94080 USA  
Phone: 650-737-1700  
Fax: 650-737-0933  
REVISION HISTORY  
Manual #  
C820M  
C820M-A  
C820M-B  
C820M-C  
C820M-D  
Date  
3/88  
9/90  
6/92  
10/97  
1/01  
Comments  
Original version.  
Added to Warning Section for UL compliance.  
Revised to cover all MS500 Series models. Added DT200 to Options section.  
Revised Figures 1 and 2. Put into new format.  
Added illustrations for terminated and looping configurations with a Coaxitron transmitter. Updated manual to new format.  
® Pelco, the Pelco logo, Spectra, Genex, Legacy, Coaxitron, and PelcoVision are registered trademarks of Pelco.  
™ Esprit and Camclosure are trademarks of Pelco.  
© Copyright 2001, Pelco.  
All rights reserved.  
12  
Pelco Manual C820M-D (1/01)  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Pelco Video Games CM6700 User Manual
Pentax Digital Camera QS 1 User Manual
Philips Clock Radio AE2170 User Manual
Philips Digital Photo Frame 7FF1CME User Manual
Plus Fax Machine BF 035 User Manual
Polaroid Digital Camera PDC 2300Z User Manual
Porter Cable Laser Level LL3100 User Manual
Poulan Snow Blower PP291E27 User Manual
PYLE Audio Automobile Accessories PNVU200 User Manual
PYLE Audio DJ Equipment PYD2200 User Manual