INSTALLATION/OPERATION
®
Spectra IV and
Spectra IV SE Series
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Welcome . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
SW1: Receiver Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
SW2 Switch 1: AD-32 Preset System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
SW2 Switch 2: CM9502 Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
SW2 Switch 3: Control System Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
SW2 Switches 4–5: Serial Port Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
SW2 Switches 6–8: Baud Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Dome Drive Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
How to Operate Your Dome System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Quick Programming Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Accessing Main Menu (Preset 95) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
CM6700/CM6800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
KBD200A/KBD300A (Direct Mode Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
CM9500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
CM9740/CM9760/CM9770/CM9780 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
KBD4000/KBD4002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
MPT9500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
NET300/NET350/NET4001A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
VCD5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
16X LowLight Color Menu Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
18X LowLight Day/Night Menu Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
22X EXview LowLight Color Menu Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
23X LowLight Day/Night Menu Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
35X LowLight Day/Night Menu Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
System Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
DIP Switch Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Display Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Label Positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
C3412M-D (12/08)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Dome Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Camera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Type of Lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Auto Focus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Zoom Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Low Light Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
IR Cut Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Advanced Camera Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Shutter Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
AGC Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Auto Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Auto Sharpness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Auto White Balance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Backlight Compensation (BLC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Video Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
SENSOR SCAN MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
FIELD ALIGN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Image Enhancement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
LOW LUX NOISE REDUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Wide Dynamic Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Motion Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Auto Flip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Proportional Pan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Park Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Scan Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Preset Freeze Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Limit Stops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Azimuth Zero . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Power Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Power Up Action . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Line Sync . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Presets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Enable Motion Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Edit Detection Areas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Activate Aux Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Aux Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Edit Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Patterns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Window Blanking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Edit Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Reverse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Clear Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Blank All Above/Blank All Below . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
4
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Aux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Edit Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Title Text . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Alert . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Repeat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Ack Action . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Activate Aux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Current Reading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Reset Alert . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Clear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Event . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Event Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Event Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Event Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Edit Event . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Clear Event . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
List Event . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Edit Holiday . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Clear Holiday . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
List Holidays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Scheduled Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Reset, Cycle Power, Reboot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Reset Camera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Cycle Camera Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Reboot System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Software/Language File Upload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Suggested Preventative Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
16X Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
18X Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
22X Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
23X Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
35X Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
C3412M-D (12/08)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Welcome
Thank you for purchasing Pelco’s premier integrated dome system, Spectra® IV/Spectra IV SE. Your new system features a high
resolution camera/optics package with programmable dome drive software.
This manual is designed primarily to be a reference tool for the installation and operation of your system. Inside you will find
information about features and commands, as well as a detailed menu tree and a quick start guide. Installation on page 7 provides
information required to set up and install the dome drive. Please thoroughly familiarize yourself with the information in this manual
before installing and using your system.
6
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
This manual contains installation instructions only for the Spectra IV/Spectra IV SE dome drive. For complete installation
instructions for a Spectra IV/Spectra IV SE dome system, refer to the installation manual shipped with the back box.
SWITCH SETTINGS
Before installing the dome drive, configure the receiver address, termination, and baud setting. The DIP switches used to
configure these settings are located on the base of the dome drive.
Figure 1 shows the default settings for the DIP switches. Switch SW1-1 (SW1, switch 1) is set to the ON position; all other
switches are set to the OFF position.
Refer to the following sections to set the address, termination, and baud settings for the dome drive.
O N
SW2
1
2
3
3
4
4
5
5
6
6
7
7
8
8
9
10
O N
SW1
1
2
Figure 1. Default Switch Settings
SW1: RECEIVER ADDRESS
Set the SW1 switches for the address of the dome drive. The following information is required to set the dome drive
address:
P-type control: The default address is 2. Refer to Table A on page 10 for address settings that use P-type control. The
maximum number of receivers is 32.
D-type control: The default address is 1. Refer to Table B on page 11 for address settings that use D-type control. The
maximum number of receivers is 254.
SW2 SWITCH 1: AD-32 PRESET SYSTEM
SW2-1 should be set to the ON position if an AD-32 controller and Pelco’s TXB-AD translator board are used to control the
dome system.
SW2 SWITCH 2: CM9502 SETTING
If a CM9502 matrix system is used with the dome drive, set SW2-2 to the ON position.
C3412M-D (12/08)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
SW2 SWITCH 3: CONTROL SYSTEM COMPATIBILITY
Coaxial Control Systems
Although Spectra IV/Spectra IV SE dome systems can operate with coaxial control systems from many manufacturers, the
system is designed for optimal performance with Pelco Coaxitron® control products within the length specified for coaxial
cable.
To compensate for coaxial control systems from other manufacturers, Pelco has provided DIP switch SW2-3. Setting
SW2-3 to the ON position may improve dome control with these control systems.
If you are using a Pelco Coaxitron controller, leave SW2-3 in the default OFF position.
Notes:
•
This coaxial control system compatibility feature is only available for dome drive revisions A4 and later (revisions A0
and later for Spectra IV Horizon dome drives). The revision number can be found on the barcode label on the top of
the dome drive. Software version 1.090 and later indicates this mode is available by placing an asterisk next to the
switch number in the Dip Switch Information menu.
•
In some configurations, Pelco CM9502 Series matrix systems use nonstandard Coaxitron commands for functions like
pattern playback. If you experience problems with these functions, set SW2-3 to the ON position.
Pelco P Protocol Control Systems
To compensate for Pelco P protocol control systems from other manufacturers, set SW2-3 to the ON position. This may
improve dome control with some of these control systems.
SW2 SWITCHES 4–5: SERIAL PORT SETTINGS
RS-422 Setting (Default)
SW2-4 and SW2-5 should both be set to the OFF position for RS-422 setting.
For control, only two wires should be connected to the RX- and RX+ connectors on the circuit board inside the back box. For
bidirectional control, four wires should be connected to the RX-, RX+, TX-, and TX+ connectors on the circuit board inside
the back box.
RS-485, 4-Wire Setting
SW2-4 should be set to OFF and SW2-5 should be set to ON if a 4-wire serial port connection is used with RS-485.
Note: This setting is most commonly used with Pelco Endura® systems.
RS-485, 2-Wire Setting
SW2-4 and SW2-5 should both be set to the ON position if a 2-wire serial port connection is used with RS-485.
This setting is used to allow the Spectra dome system to transmit and receive commands on the same pair of wires. Only
two wires should be connected to the RX- and RX+ connectors on the circuit board inside the back box.
8
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
SW2 SWITCHES 6–8: BAUD SETTINGS
Pelco’s D-type controllers are set for 2400 baud. The default setting for the dome drive is 2400 baud. If you are using a
Pelco D-type controller, do not reset SW2 switches 1–3 or SW2 switches 6–8.
P-type controllers can operate at 2400, 4800, and 9600 baud. Set the SW2 switches (6, 7, and 8), located on the base of
the dome drive, to the same baud as the P-type controller.
Switch Number
SW2-6
Off
SW2-7
Off
SW2-8
Off
2400 Baud (default for D-type control)
4800 Baud (default for P-type control)
9600 Baud
On
Off
Off
Off
On
Off
SW2 Switch 9: Coaxial/UTP Cable
SW2-9 should be set to the OFF position (default) if you are using coaxial cable. If you are using unsheilded twisted pair
(UTP) cable, set SW2-9 to the ON position.
SW2 Switch 10: Termination Setting
When connecting more than one Spectra IV/Spectra IV SE dome system to a single controller, terminate the unit farthest
from the controller. Termination is only required for the last dome in the series.
The dome drive is shipped from the factory in the unterminated (OFF) position. To terminate the dome drive, set SW2-10 to
the ON position.
Note: Dome termination is not required for Coaxitron® control.
DOME DRIVE INSTALLATION
Install the dome drive. Align the blue and red tabs with the blue and red arrows on the hinged door inside the back box.
Push the tabs in. Insert one side and then the other side. Continue pushing on the ends of the tabs until both sides click
Figure 2. Dome Drive Installation
Note: When removing a dome drive that has been in use, caution should be taken to avoid direct contact with the top
plate of the unit. This section of the unit will be warm to the touch when first removed from an operating unit.
C3412M-D (12/08)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Table A. Switch Settings for SW1 P-Type Control
SWITCH SETTING
SPECTRA
ADDRESS
SW1-1
OFF
ON
SW1-2
OFF
OFF
ON
SW1-3
OFF
OFF
OFF
OFF
ON
SW1-4
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
SW1-5
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
SW1-6
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
SW1-7
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
SW1-8
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
1
2
3
OFF
ON
4
ON
5
OFF
ON
OFF
OFF
ON
6
ON
7
OFF
ON
ON
8
ON
ON
9
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
10
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
Table B. Switch Settings for SW1 D-Type Control
SWITCH SETTING
SPECTRA
ADDRESS
SW1-1
ON
SW1-2
OFF
ON
SW1-3
OFF
OFF
OFF
ON
SW1-4
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
SW1-5
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
SW1-6
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
SW1-7
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
SW1-8
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
1
2
OFF
ON
3
ON
4
OFF
ON
OFF
OFF
ON
5
ON
6
OFF
ON
ON
7
ON
ON
8
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
9
ON
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
ON
ON
C3412M-D (12/08)
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Table B. Switch Settings for SW1 D-Type Control (Continued)
SWITCH SETTING
SPECTRA
ADDRESS
SW1-1
OFF
ON
SW1-2
OFF
OFF
ON
SW1-3
ON
SW1-4
OFF
OFF
OFF
OFF
ON
SW1-5
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
SW1-6
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
SW1-7
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
SW1-8
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
12
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
Table B. Switch Settings for SW1 D-Type Control (Continued)
SWITCH SETTING
SPECTRA
ADDRESS
SW1-1
ON
SW1-2
ON
SW1-3
ON
SW1-4
OFF
ON
SW1-5
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
SW1-6
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
SW1-7
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
SW1-8
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
C3412M-D (12/08)
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Table B. Switch Settings for SW1 D-Type Control (Continued)
SWITCH SETTING
SPECTRA
ADDRESS
SW1-1
OFF
ON
SW1-2
ON
SW1-3
OFF
OFF
ON
SW1-4
ON
SW1-5
OFF
OFF
OFF
OFF
OFF
OFF
ON
SW1-6
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
SW1-7
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
SW1-8
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
14
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
Table B. Switch Settings for SW1 D-Type Control (Continued)
SWITCH SETTING
SPECTRA
ADDRESS
SW1-1
ON
SW1-2
OFF
ON
SW1-3
ON
SW1-4
ON
SW1-5
OFF
OFF
OFF
ON
SW1-6
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
SW1-7
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
SW1-8
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
C3412M-D (12/08)
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Table B. Switch Settings for SW1 D-Type Control (Continued)
SWITCH SETTING
SPECTRA
ADDRESS
SW1-1
OFF
ON
SW1-2
OFF
OFF
ON
SW1-3
OFF
OFF
OFF
OFF
ON
SW1-4
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
SW1-5
ON
SW1-6
ON
SW1-7
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
SW1-8
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
ON
ON
16
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
Table B. Switch Settings for SW1 D-Type Control (Continued)
SWITCH SETTING
SPECTRA
ADDRESS
SW1-1
ON
SW1-2
ON
SW1-3
OFF
ON
SW1-4
OFF
OFF
OFF
OFF
OFF
ON
SW1-5
ON
SW1-6
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
SW1-7
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
SW1-8
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
C3412M-D (12/08)
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Table B. Switch Settings for SW1 D-Type Control (Continued)
SWITCH SETTING
SPECTRA
ADDRESS
SW1-1
OFF
ON
SW1-2
ON
SW1-3
ON
SW1-4
OFF
OFF
ON
SW1-5
ON
SW1-6
ON
SW1-7
ON
SW1-8
ON
246
247
248
249
250
251
252
253
254
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
18
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
Getting Started
Once installed, apply power to the Spectra IV/Spectra IV SE dome system. The system will start a configuration sequence.
When configuration is done, the following information is displayed:
Pelco Spectra IV/Spectra IV SE
Version X.XX
D Address: 1
P Address: 2
Comm 2400, N, 8, 1
CONFIGURE DONE
This information will remain on the monitor until dome operation begins.
Note: When installing a Spectra IV dome drive in a Spectra III™ back box for the first time, a message appears. When the
installation is complete, the dome drive will continue with a normal configuration sequence.
C3412M-D (12/08)
19
Download from Www.Somanuals.com. All Manuals Search And Download.
How to Operate Your Dome System
Operation
Pan and Tilt
Zoom Far
How to Control
Move the joystick or press the direction keys left/right and up/down.
To zoom far:
1. Press the Zoom Tele button or turn the joystick clockwise until zoom stops at the optical zoom
limit.
2. Release the button or joystick for one second.
3. To continue zooming (digitally), press the button or turn the joystick clockwise again until you
have the picture you want or reach the digital zoom1 limit.
Zoom Wide
Scanning
Press the Zoom Wide button or turn the joystick counterclockwise.
Stop Scan
Preset 96
Preset 97
Preset 98
Preset 99
Random Scan
Frame Scan
Auto Scan
Presets
Patterns2
Zones
Refer to the documentation supplied with the control system.
Refer to the documentation supplied with the control system.
Alarms
Auto Flip
1 Digital zoom magnifies the image electronically and the picture may appear pixilated. The larger the digital zoom limit the greater the
reduction in resolution.
2 The dome cannot do electronic zoom in a pattern. Optical zoom will operate in a pattern.
20
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICK PROGRAMMING GUIDE
Use the joystick to position the cursor beside menu selection.
Note: If your controller does not have a joystick, use the up or down key.
Press Iris Open, the submenu/cursor moves to the right.
Move the joystick up or down to view selections.
Press Iris Open to make a selection.
Press Iris Close to cancel a selection.
ACCESSING MAIN MENU (PRESET 95)
You can call up the main menu on your monitor by programming (setting or creating) preset 95 (preset 28 in AD32-preset
mode).
Programming preset 95 for Pelco’s controllers varies according to the type of controller you are using. Instructions for
programming preset 95 are given below for various Pelco controllers.
CM6700/CM6800
1. Enter the number of the Spectra IV/Spectra IV SE dome system and press the CAM key.
2. Enter 95 and hold the PRESET key for two seconds.
3. In the Edit Preset menu, go to SET and press the ACK key. The main menu appears.
KBD200A/KBD300A (Direct Mode Only)
1. Enter 95.
2. Hold the PRESET key (approximately five seconds) until the main menu appears on the screen.
C3412M-D (12/08)
21
Download from Www.Somanuals.com. All Manuals Search And Download.
CM9500
1. Enter the number of the Spectra IV/Spectra IV SE dome system and press the CAM key. The main menu appears.
2. Highlight SETUP in the main menu and press the SELECT key.
3. Highlight CAM in the Setup menu and press the SELECT key.
4. Highlight PRESET in the Camera menu and press the SELECT key.
5. Enter 95 and press the F1 key. The main menu appears.
CM9740/CM9760/CM9770/CM9780
1. Press the ESCAPE key to open the main menu. Select DEF. The Define submenu appears.
2. Enter your four-digit PIN if this is your first time entering this mode.
3. Enter 95 and select PRST. The main menu appears on the monitor.
4. Select the Quit icon to return to the default menu.
KBD4000/KBD4002
1. Press the SPOT MONITOR key.
2. Enter 95, then hold the PRESET key (approximately five seconds) until the main menu appears on the screen.
MPT9500
Standard Coaxitron Mode
1. Enter 95 and press the PRESET SET key.
2. Position the asterisk in the YES row and press the F1 key. The main menu appears.
Extended Coaxitron or RS-485 Mode
1. Enter 95 and press the PRESET SET key.
2. Press the F2 key. The main menu appears.
22
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
NET300/NET350/NET4001A
1. Check the Set box.
2. Click the preset 95 button. The main menu appears.
ENDURA WORKSTATION
1. Right-click in the video pane of the Spectra IV/Spectra IV SE dome system.
2. Click Preset and then click Select Preset.
3. Enter 95 and then click OK.
VCD5000
1. Enter 95 for the preset action. The shortcuts menu appears.
2. Press the Preset button on the KBD5000.
C3412M-D (12/08)
23
Download from Www.Somanuals.com. All Manuals Search And Download.
16X LowLight Color Menu Tree
SPECTRA IV
LANGUAGE
ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
SYSTEM INFORMATION
DISPLAY SETUP
SERIAL #
XXXXXXXXXXXXXX
XX-XXXX
PRESET LABEL
2 (SECS)
2 (SECS)
2 (SECS)
2 (SECS)
OFF
DOME DRIVE MODEL
BACK BOX MEMORY
SOFTWARE VERSION
BUILD
ZONE LABEL
ZOOM
AVAILABLE
XX.X
AZIMUTH/ELEVATION
DIRECTION
FONT VERSION
COMM
XX.X
ALARM MESSAGE
DATE/TIME
2 (SECS)
ON
XXXXXXXXXX
D ADDRESS
1
2
EVENT LABEL
2 (SECS)
P ADDRESS
CM95OO MODE
32 PRESETS
OFF
OFF
C
<LABEL POSITIONS>
RESTORE FACTORY DEFAULTS
PROTOCOL
DIPSWITCH INFORMATION
PRESSURIZED*
<ADDITIONAL>
X.XX
LABEL POSITION
12345678
1234567890
SW1[--------] SW2[----------]
[ZONE LABEL-------]
[PRESET LABEL-------]
[ALARM 1-------]
ADDITIONAL
SW1 1-8:
D ADDRESS 1
FREE MEMORY
LATEST RESET
XXXXXX
[ALERT MESSAGE---]*
P ADDRESS 1
POWER ON
SW2 1 : 32 PRESETS. OFF
SW2 2 : CM9500 MODE. OFF
SW2 3 : COAX SPIV
SW2 4-5 : RS422 <->
AZIMUTH ZERO OFFSET
MOTOR ACTIVE
CAMERA ACTIVE
VIDEO LEVEL
0°
YES
SAVE AND EXIT
CANCEL AND EXIT
HELP
YES
NORMAL
XXXX-XXXX
ENGLISH X.XX
XXX/-XX
SW2 6-8 : COMM. 2400.N.8.1
SW2 9 : UTC SOURCE. COAX
SW2 10 : TX/RX TERM.. OFF
CAMERA MODEL
LANGUAGE 1
NE
XXX.XX
. . .
LANGUAGE 10
ITALIANO X.XX
PRESS IRIS OPEN TO CONTINUE
<DIPSWITCH INFORMATION>
CAMERA
ADVANCED SETTINGS
MOTION
POWER UP
AUTO FOCUS
SURE FOCUS
ZOOM LIMIT
ON
OFF
SUTTER SPEED
AGC LIMIT
AUTO
28
AUTO FLIP
ON
ON
POWER UP ACTION
AUTO
PROPORTIONAL PAN
PARK TIME (MINUTES)
PARK ACTION
XXXX
AUTO IRIS
AUTO
66
0
ZOOM SPEED
LOW LIGHT LIMIT
XXXX
XXXXXX
AUTO IRIS LEVEL
AUTO IRIS PEAK
AUTO SHARPNESS
SHARPNESS LEVEL
AUTO WHITE BALANCE
R GAIN
B GAIN
BACKLIGHT COMP
VIDEO LEVEL
NONE
25
AUTO
ON
8
ON
26
ON
255
255
OFF
HIGH
SCAN SPEED DEG/S
PRESET FREEZE FRAME
LIMIT STOPS
<SET MANUAL STOPS>
<CLEAR MANUAL STOPS>
<SET SCAN STOPS>
<CLEAR SCAN STOPS>
<SET AZIMUTH ZERO>
<CLEAR AZIMUTH ZERO>
<ADVANCED SETTINGS>
ZONES
WINDOW BLANKING
SET WINDOWS
ALARMS
ZONE NUMBER
1
STYLE
GRAY
OFF
OFF
WINDOW NUMBER
<EDIT WINDOW LOCATION>
<EDIT WINDOW ZOOM>
<EDIT SCHEDULE>
ENABLE WINDOW
REVERSE
1
ALARM CONTACT
***ZONE NOT DEFINED***
<EDIT ZONE LABEL>
<EDIT ZONE>
BLANK ALL ABOVE
BLANK ALL BELOW
<SET WINDOWS>
NO
ZONE ENABLED
ZONE BLANKING
<CLEAR ZONE>
ON
OFF
CLEAR WINDOW
ALERT*
REPEAT
CURRENT READING
CLEAR
PASSWORD
CONSTANT
TEMPERATURE
DEWPOINT
PRESURE
CLEAR ALL ZONES
ENABLE PASSWORD
<EDIT PASSWORD>
OFF
ACK ACTION
ALWAYS ON
CLEAR ALL PRESETS
CLEAR ALL PATTERNS
ACTIVATE AUX
<CURRENT READING>
RESET ALERT
NO
REFRESH
CLEAR ALL WINDOW BLANKING
CLEAR ALL EVENTS
RESTORE FACTORY DEFAULTS
*This setting applies only to Pressurized Spectra IV dome systems. Spectra IV systems that are not pressurized will not display this menu item.
24
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
LINE SYNC
PRESETS
PATTERNS
LINE SYNC
LINE SYNC PHASE
ON
0
PRESET NUMBER
1
PATTERN NUMBER
1
***PRESET NOT DEFINED***
<EDIT PRESET LABEL>
<EDIT PRESET SCENE>
<EDIT SCHEDULE>
<CLEAR PRESET>
<PROGRAM PATTERN>
<CLEAR PATTERN>
<EDIT SCHEDULE>
REFERENCE INFO
PATTERN USAGE
REMAINING
0%
100%
<CLEAR CAMERA SETTINGS>
REFERENCE INFORMATION
AZIMUTH
ELEVATION
ZOOM
AUX
TITLE TEXT
AUX 1 MODE
TOGGLE
ENABLE TITLE TEXT
<EDIT TITLE TEXT>
DWELL TIME (SECS)
AUX 2 MODE
1
TOGGLE
1
DWELL TIME (SECS)
<EDIT SCHEDULE>
EDIT THE PASSWORD
CLOCK
EVENT
EDIT EVENT
1234567890
ABCDEFGHIJ
KLMNOPQRST
UVWXYZ.,-/
abcdefghij
klmnopqrst
uvwxyz#&:*
TIME BASE
INTERNAL CLOCK
12 HOUR
EVENT TYPE
ALL EVENTS
EVENT LABEL
EVENT01
TIME FORMAT
SET TIME
EVENT LABEL
NEW
12:00 AM
EVENT ACTIVE
EVENT TIME
EVENT OCCURS
SUNDAY
ON
12:00 AM
DATE FORMAT
SET DATE
DAYLIGHT SAVINGS
MM/DD/YYYY
00/00/0000
OFF
<EDIT EVENT LABEL>
<EDIT EVENT>
<CLEAR EVENT>
<LIST EVENT>
ON
MONDAY
ON
TUESDAY
ON
HOLIDAY
WEDNESDAY
THURSDAY
FRIDAY
ON
<EDIT HOLIDAY>
<CLEAR HOLIDAY>
<LIST HOLIDAYS>
ON
ON
ON
SATURDAY
HOLIDAY
SKIP HOLIDAYS
EVENT TYPE
PRESET
C3412M-D (12/08)
25
Download from Www.Somanuals.com. All Manuals Search And Download.
18X LowLight Day/Night Menu Tree
SPECTRA IV
LANGUAGE
ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
SYSTEM INFORMATION
DISPLAY SETUP
SERIAL #
XXXXXXXXXXXXXX
XX-XXXX
PRESET LABEL
2 (SECS)
2 (SECS)
2 (SECS)
2 (SECS)
OFF
DOME DRIVE MODEL
BACK BOX MEMORY
SOFTWARE VERSION
BUILD
ZONE LABEL
ZOOM
AVAILABLE
XX.X
AZIMUTH/ELEVATION
DIRECTION
FONT VERSION
COMM
XX.X
ALARM MESSAGE
DATE/TIME
2 (SECS)
ON
XXXXXXXXXX
D ADDRESS
1
2
EVENT LABEL
2 (SECS)
P ADDRESS
CM95OO MODE
32 PRESETS
OFF
OFF
C
<LABEL POSITIONS>
RESTORE FACTORY DEFAULTS
PROTOCOL
DIPSWITCH INFORMATION
PRESSURIZED*
<ADDITIONAL>
X.XX
LABEL POSITION
12345678
1234567890
SW1[--------] SW2[----------]
[ZONE LABEL-------]
[PRESET LABEL-------]
[ALARM 1-------]
ADDITIONAL
SW1 1-8:
D ADDRESS 1
FREE MEMORY
LATEST RESET
AZIMUTH ZERO OFFSET
MOTOR ACTIVE
CAMERA ACTIVE
VIDEO LEVEL
XXXXXX
POWER ON
0°
[ALERT MESSAGE---]*
P ADDRESS 1
SW2 1 : 32 PRESETS. OFF
SW2 2 : CM9500 MODE. OFF
SW2 3 : COAX SPIV
SW2 4-5 : RS422 <->
SAVE AND EXIT
CANCEL AND EXIT
HELP
YES
YES
NORMAL
XXXX-XXXX
ENGLISH X.XX
XXX/-XX
SW2 6-8 : COMM. 2400.N.8.1
SW2 9 : UTC SOURCE. COAX
SW2 10 : TX/RX TERM.. OFF
CAMERA MODEL
LANGUAGE 1
NE
XXX.XX
. . .
LANGUAGE 10
ITALIANO X.XX
PRESS IRIS OPEN TO CONTINUE
<DIPSWITCH INFORMATION>
CAMERA
ADVANCED SETTINGS
MOTION
POWER UP
AUTO FOCUS
ON
OFF
SUTTER SPEED
AGC LIMIT
AUTO
28
AUTO FLIP
ON
ON
POWER UP ACTION
AUTO
SURE FOCUS
PROPORTIONAL PAN
PARK TIME (MINUTES)
PARK ACTION
ZOOM LIMIT
XXXX
XXXX
XXXXXX
XXXX
OFF
AUTO IRIS
AUTO
66
0
ZOOM SPEED
AUTO IRIS LEVEL
AUTO IRIS PEAK
AUTO SHARPNESS
SHARPNESS LEVEL
AUTO WHITE BALANCE
R GAIN
NONE
25
AUTO
ON
LOW LIGHT LIMIT
IR CUT FILTER
8
ON
26
ON
255
255
OFF
HIGH
OFF
ON
SCAN SPEED DEG/S
PRESET FREEZE FRAME
LIMIT STOPS
<SET MANUAL STOPS>
<CLEAR MANUAL STOPS>
<SET SCAN STOPS>
<CLEAR SCAN STOPS>
<SET AZIMUTH ZERO>
<CLEAR AZIMUTH ZERO>
LOW LIGHT FOCUS
AUTO IR LEVEL
<ADVANCED SETTINGS>
AUTO
B GAIN
BACKLIGHT COMP
VIDEO LEVEL
FIELD ALIGN
LOW LUX NOISE REDUCTION
ZONES
WINDOW BLANKING
SET WINDOWS
ZONE NUMBER
1
STYLE
GRAY
OFF
OFF
WINDOW NUMBER
<EDIT WINDOW LOCATION>
<EDIT WINDOW ZOOM>
<EDIT SCHEDULE>
ENABLE WINDOW
REVERSE
1
***ZONE NOT DEFINED***
<EDIT ZONE LABEL>
<EDIT ZONE>
BLANK ALL ABOVE
BLANK ALL BELOW
<SET WINDOWS>
NO
ZONE ENABLED
ZONE BLANKING
<CLEAR ZONE>
ON
OFF
CLEAR WINDOW
ALERT*
REPEAT
CURRENT READING
CLEAR
PASSWORD
CONSTANT
TEMPERATURE
DEWPOINT
PRESURE
CLEAR ALL ZONES
ENABLE PASSWORD
<EDIT PASSWORD>
OFF
ACK ACTION
ALWAYS ON
CLEAR ALL PRESETS
CLEAR ALL PATTERNS
ACTIVATE AUX
<CURRENT READING>
RESET ALERT
NO
REFRESH
CLEAR ALL WINDOW BLANKING
CLEAR ALL EVENTS
RESTORE FACTORY DEFAULTS
*This setting applies only to Pressurized Spectra IV dome systems. Spectra IV systems that are not pressurized will not display this menu item.
26
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
LINE SYNC
PRESETS
PATTERNS
LINE SYNC
LINE SYNC PHASE
ON
0
PRESET NUMBER
1
PATTERN NUMBER
1
***PRESET NOT DEFINED***
<EDIT PRESET LABEL>
<EDIT PRESET SCENE>
<EDIT CAMERA SETTINGS>
<EDIT SCHEDULE>
<CLEAR PRESET>
<PROGRAM PATTERN>
<CLEAR PATTERN>
<EDIT SCHEDULE>
REFERENCE INFO
PATTERN USAGE
REMAINING
0%
100%
<CLEAR CAMERA SETTINGS>
REFERENCE INFORMATION
AZIMUTH
ELEVATION
ZOOM
ALARMS
AUX
TITLE TEXT
ALARM CONTACT
AUX 1 MODE
TOGGLE
ENABLE TITLE TEXT
<EDIT TITLE TEXT>
DWELL TIME (SECS)
AUX 2 MODE
1
TOGGLE
1
DWELL TIME (SECS)
<EDIT SCHEDULE>
EDIT THE PASSWORD
CLOCK
EVENT
EDIT EVENT
1234567890
ABCDEFGHIJ
KLMNOPQRST
UVWXYZ.,-/
abcdefghij
klmnopqrst
uvwxyz#&:*
TIME BASE
INTERNAL CLOCK
12 HOUR
EVENT TYPE
ALL EVENTS
EVENT LABEL
EVENT01
TIME FORMAT
SET TIME
EVENT LABEL
NEW
12:00 AM
EVENT ACTIVE
EVENT TIME
EVENT OCCURS
SUNDAY
ON
12:00 AM
DATE FORMAT
SET DATE
DAYLIGHT SAVINGS
MM/DD/YYYY
00/00/0000
OFF
<EDIT EVENT LABEL>
<EDIT EVENT>
<CLEAR EVENT>
<LIST EVENT>
ON
MONDAY
ON
TUESDAY
ON
HOLIDAY
WEDNESDAY
THURSDAY
FRIDAY
ON
<EDIT HOLIDAY>
<CLEAR HOLIDAY>
<LIST HOLIDAYS>
ON
ON
ON
SATURDAY
HOLIDAY
SKIP HOLIDAYS
EVENT TYPE
PRESET
C3412M-D (12/08)
27
Download from Www.Somanuals.com. All Manuals Search And Download.
22X EXview LowLight Color Menu Tree
SPECTRA IV
LANGUAGE
ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
SYSTEM INFORMATION
DISPLAY SETUP
SERIAL #
XXXXXXXXXXXXXX
XX-XXXX
PRESET LABEL
2 (SECS)
2 (SECS)
2 (SECS)
2 (SECS)
OFF
DOME DRIVE MODEL
BACK BOX MEMORY
SOFTWARE VERSION
BUILD
ZONE LABEL
ZOOM
AVAILABLE
XX.X
AZIMUTH/ELEVATION
DIRECTION
FONT VERSION
COMM
XX.X
ALARM MESSAGE
DATE/TIME
2 (SECS)
ON
XXXXXXXXXX
D ADDRESS
1
2
EVENT LABEL
2 (SECS)
P ADDRESS
CM95OO MODE
32 PRESETS
OFF
OFF
C
<LABEL POSITIONS>
RESTORE FACTORY DEFAULTS
PROTOCOL
DIPSWITCH INFORMATION
PRESSURIZED*
<ADDITIONAL>
X.XX
LABEL POSITION
12345678
1234567890
SW1[--------] SW2[----------]
[ZONE LABEL-------]
[PRESET LABEL-------]
[ALARM 1-------]
ADDITIONAL
SW1 1-8:
D ADDRESS 1
FREE MEMORY
LATEST RESET
XXXXXX
[ALERT MESSAGE---]*
P ADDRESS 1
POWER ON
SW2 1 : 32 PRESETS. OFF
SW2 2 : CM9500 MODE. OFF
SW2 3 : COAX SPIV
SW2 4-5 : RS422 <->
AZIMUTH ZERO OFFSET
MOTOR ACTIVE
CAMERA ACTIVE
VIDEO LEVEL
0°
YES
SAVE AND EXIT
CANCEL AND EXIT
HELP
YES
NORMAL
XXXX-XXXX
ENGLISH X.XX
XXX/-XX
SW2 6-8 : COMM. 2400.N.8.1
SW2 9 : UTC SOURCE. COAX
SW2 10 : TX/RX TERM.. OFF
CAMERA MODEL
LANGUAGE 1
NE
XXX.XX
. . .
LANGUAGE 10
ITALIANO X.XX
PRESS IRIS OPEN TO CONTINUE
<DIPSWITCH INFORMATION>
CAMERA
ADVANCED SETTINGS
MOTION
POWER UP
TYPE OF LIGHTING
AUTO FOCUS
T1
ON
SUTTER SPEED
AGC LIMIT
AUTO
28
AUTO FLIP
ON
ON
POWER UP ACTION
AUTO
PROPORTIONAL PAN
PARK TIME (MINUTES)
PARK ACTION
SURE FOCUS
OFF
AUTO IRIS
AUTO
66
0
ZOOM LIMIT
XXXX
XXXX
XXXXXX
AUTO IRIS LEVEL
AUTO IRIS PEAK
AUTO SHARPNESS
SHARPNESS LEVEL
AUTO WHITE BALANCE
R GAIN
NONE
25
AUTO
ON
ZOOM SPEED
8
ON
26
ON
255
255
OFF
SCAN SPEED DEG/S
PRESET FREEZE FRAME
LIMIT STOPS
<SET MANUAL STOPS>
<CLEAR MANUAL STOPS>
<SET SCAN STOPS>
<CLEAR SCAN STOPS>
<SET AZIMUTH ZERO>
<CLEAR AZIMUTH ZERO>
LOW LIGHT LIMIT
<ADVANCED SETTINGS>
B GAIN
BACKLIGHT COMP
ZONES
WINDOW BLANKING
SET WINDOWS
ZONE NUMBER
1
STYLE
GRAY
OFF
OFF
WINDOW NUMBER
<EDIT WINDOW LOCATION>
<EDIT WINDOW ZOOM>
<EDIT SCHEDULE>
ENABLE WINDOW
REVERSE
1
***ZONE NOT DEFINED***
<EDIT ZONE LABEL>
<EDIT ZONE>
BLANK ALL ABOVE
BLANK ALL BELOW
<SET WINDOWS>
NO
ZONE ENABLED
ZONE BLANKING
<CLEAR ZONE>
ON
OFF
CLEAR WINDOW
ALERT*
REPEAT
CURRENT READING
CLEAR
PASSWORD
CONSTANT
TEMPERATURE
DEWPOINT
PRESURE
CLEAR ALL ZONES
ENABLE PASSWORD
<EDIT PASSWORD>
OFF
ACK ACTION
ALWAYS ON
CLEAR ALL PRESETS
CLEAR ALL PATTERNS
ACTIVATE AUX
<CURRENT READING>
RESET ALERT
NO
REFRESH
CLEAR ALL WINDOW BLANKING
CLEAR ALL EVENTS
RESTORE FACTORY DEFAULTS
*This setting applies only to Pressurized Spectra IV dome systems. Spectra IV systems that are not pressurized will not display this menu item.
28
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
LINE SYNC
PRESETS
PATTERNS
LINE SYNC
LINE SYNC PHASE
ON
0
PRESET NUMBER
1
PATTERN NUMBER
1
***PRESET NOT DEFINED***
<EDIT PRESET LABEL>
<EDIT PRESET SCENE>
<EDIT CAMERA SETTINGS>
<EDIT SCHEDULE>
<PROGRAM PATTERN>
<CLEAR PATTERN>
<EDIT SCHEDULE>
REFERENCE INFO
PATTERN USAGE
REMAINING
0%
100%
<CLEAR PRESET>
<CLEAR CAMERA SETTINGS>
REFERENCE INFORMATION
AZIMUTH
ELEVATION
ZOOM
CUSTOM CAMERA SETTINGS
ALARMS
ALARM SETTINGS
AUX
TITLE TEXT
RESUME
OFF
5
0
ALARM NUMBER
1
LOW
NONE
NO
AUX 1 MODE
TOGGLE
ENABLE TITLE TEXT
<EDIT TITLE TEXT>
SEQUENCE (SECS)
RESET DELAY (SECS)
<ALARM SETTINGS>
ALARM PRIORITY
ALARM ACTION
ACTIVATE AUX
DWELL TIME (SECS)
AUX 2 MODE
1
TOGGLE
1
DWELL TIME (SECS)
<EDIT SCHEDULE>
ALARM CONTACT
<EDIT SCHEDULE>
N/O
EDIT THE PASSWORD
CLOCK
EVENT
EDIT EVENT
1234567890
ABCDEFGHIJ
KLMNOPQRST
UVWXYZ.,-/
abcdefghij
klmnopqrst
uvwxyz#&:*
TIME BASE
INTERNAL CLOCK
12 HOUR
EVENT TYPE
ALL EVENTS
EVENT LABEL
EVENT01
TIME FORMAT
SET TIME
EVENT LABEL
NEW
12:00 AM
EVENT ACTIVE
EVENT TIME
EVENT OCCURS
SUNDAY
ON
12:00 AM
DATE FORMAT
SET DATE
DAYLIGHT SAVINGS
MM/DD/YYYY
00/00/0000
OFF
<EDIT EVENT LABEL>
<EDIT EVENT>
<CLEAR EVENT>
<LIST EVENT>
ON
MONDAY
ON
TUESDAY
ON
HOLIDAY
WEDNESDAY
THURSDAY
FRIDAY
ON
<EDIT HOLIDAY>
<CLEAR HOLIDAY>
<LIST HOLIDAYS>
ON
ON
ON
SATURDAY
HOLIDAY
SKIP HOLIDAYS
EVENT TYPE
PRESET
C3412M-D (12/08)
29
Download from Www.Somanuals.com. All Manuals Search And Download.
23X LowLight Day/Night Menu Tree
SPECTRA IV
LANGUAGE
ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
SYSTEM INFORMATION
DISPLAY SETUP
SERIAL #
XXXXXXXXXXXXXX
XX-XXXX
PRESET LABEL
2 (SECS)
2 (SECS)
2 (SECS)
2 (SECS)
OFF
DOME DRIVE MODEL
BACK BOX MEMORY
SOFTWARE VERSION
BUILD
ZONE LABEL
ZOOM
AVAILABLE
XX.X
AZIMUTH/ELEVATION
DIRECTION
FONT VERSION
COMM
XX.X
ALARM MESSAGE
DATE/TIME
2 (SECS)
ON
XXXXXXXXXX
D ADDRESS
1
2
EVENT LABEL
2 (SECS)
P ADDRESS
CM95OO MODE
32 PRESETS
OFF
OFF
C
<LABEL POSITIONS>
RESTORE FACTORY DEFAULTS
PROTOCOL
DIPSWITCH INFORMATION
PRESSURIZED*
<ADDITIONAL>
X.XX
LABEL POSITION
12345678
1234567890
SW1[--------] SW2[----------]
[ZONE LABEL-------]
[PRESET LABEL-------]
[ALARM 1-------]
ADDITIONAL
SW1 1-8:
D ADDRESS 1
FREE MEMORY
LATEST RESET
AZIMUTH ZERO OFFSET
MOTOR ACTIVE
CAMERA ACTIVE
VIDEO LEVEL
XXXXXX
POWER ON
0°
[ALERT MESSAGE---]*
P ADDRESS 1
SW2 1 : 32 PRESETS. OFF
SW2 2 : CM9500 MODE. OFF
SW2 3 : COAX SPIV
SW2 4-5 : RS422 <->
SAVE AND EXIT
CANCEL AND EXIT
HELP
YES
YES
NORMAL
XXXX-XXXX
ENGLISH X.XX
XXX/-XX
SW2 6-8 : COMM. 2400.N.8.1
SW2 9 : UTC SOURCE. COAX
SW2 10 : TX/RX TERM.. OFF
CAMERA MODEL
LANGUAGE 1
NE
XXX.XX
. . .
LANGUAGE 10
ITALIANO X.XX
PRESS IRIS OPEN TO CONTINUE
<DIPSWITCH INFORMATION>
CAMERA
ADVANCED SETTINGS
MOTION
POWER UP
TYPE OF LIGHTING
AUTO FOCUS
T1
ON
SUTTER SPEED
AGC LIMIT
AUTO
28
AUTO FLIP
ON
ON
POWER UP ACTION
AUTO
PROPORTIONAL PAN
PARK TIME (MINUTES)
PARK ACTION
SURE FOCUS
OFF
AUTO IRIS
AUTO
66
0
ZOOM LIMIT
XXXX
XXXX
XXXXXX
XXXX
OFF
AUTO IRIS LEVEL
AUTO IRIS PEAK
AUTO SHARPNESS
SHARPNESS LEVEL
AUTO WHITE BALANCE
R GAIN
NONE
25
AUTO
ON
ZOOM SPEED
8
ON
26
ON
255
255
OFF
HIGH
OFF
ON
SCAN SPEED DEG/S
PRESET FREEZE FRAME
LIMIT STOPS
<SET MANUAL STOPS>
<CLEAR MANUAL STOPS>
<SET SCAN STOPS>
<CLEAR SCAN STOPS>
<SET AZIMUTH ZERO>
<CLEAR AZIMUTH ZERO>
LOW LIGHT LIMIT
IR CUT FILTER
LOW LIGHT FOCUS
AUTO IR LEVEL
<ADVANCED SETTINGS>
AUTO
B GAIN
BACKLIGHT COMP
VIDEO LEVEL
FIELD ALIGN
LOW LUX NOISE REDUCTION
ZONES
WINDOW BLANKING
SET WINDOWS
ZONE NUMBER
1
STYLE
GRAY
OFF
OFF
WINDOW NUMBER
<EDIT WINDOW LOCATION>
<EDIT WINDOW ZOOM>
<EDIT SCHEDULE>
ENABLE WINDOW
REVERSE
1
***ZONE NOT DEFINED***
<EDIT ZONE LABEL>
<EDIT ZONE>
BLANK ALL ABOVE
BLANK ALL BELOW
<SET WINDOWS>
NO
ZONE ENABLED
ZONE BLANKING
<CLEAR ZONE>
ON
OFF
CLEAR WINDOW
ALERT*
REPEAT
CURRENT READING
CLEAR
PASSWORD
CONSTANT
TEMPERATURE
DEWPOINT
PRESURE
CLEAR ALL ZONES
ENABLE PASSWORD
<EDIT PASSWORD>
OFF
ACK ACTION
ALWAYS ON
CLEAR ALL PRESETS
CLEAR ALL PATTERNS
ACTIVATE AUX
<CURRENT READING>
RESET ALERT
NO
REFRESH
CLEAR ALL WINDOW BLANKING
CLEAR ALL EVENTS
RESTORE FACTORY DEFAULTS
*This setting applies only to Pressurized Spectra IV dome systems. Spectra IV systems that are not pressurized will not display this menu item.
30
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
LINE SYNC
PRESETS
EDIT DETECTION AREAS
PATTERNS
LINE SYNC
LINE SYNC PHASE
ON
0
PRESET NUMBER
1
DETECTION AREA 1
PATTERN NUMBER
1
***PRESET NOT DEFINED***
<EDIT PRESET LABEL>
<EDIT PRESET SCENE>
<EDIT CAMERA SETTINGS>
<EDIT SCHEDULE>
<CLEAR PRESET>
LOCATION
SENSITIVITY
0
<PROGRAM PATTERN>
<CLEAR PATTERN>
<EDIT SCHEDULE>
MEDIUM
DETECTION AREA 2
LOCATION
0
SENSITIVITY
MEDIUM
REFERENCE INFO
PATTERN USAGE
REMAINING
0%
100%
DETECTION AREA 3
LOCATION
<CLEAR CAMERA SETTINGS>
REFERENCE INFORMATION
AZIMUTH
ELEVATION
ZOOM
0
SENSITIVITY
MEDIUM
DETECTION AREA 4
LOCATION
0
SENSITIVITY
MEDIUM
ALARMS
ALARM SETTINGS
AUX
TITLE TEXT
RESUME
OFF
5
0
ALARM NUMBER
ALARM PRIORITY
ALARM ACTION
ACTIVATE AUX
ALARM CONTACT
<EDIT SCHEDULE>
1
LOW
NONE
NO
AUX 1 MODE
TOGGLE
ENABLE TITLE TEXT
<EDIT TITLE TEXT>
SEQUENCE (SECS)
RESET DELAY (SECS)
<ALARM SETTINGS>
DWELL TIME (SECS)
AUX 2 MODE
1
TOGGLE
1
DWELL TIME (SECS)
<EDIT SCHEDULE>
N/O
EDIT THE PASSWORD
CLOCK
EVENT
EDIT EVENT
1234567890
ABCDEFGHIJ
KLMNOPQRST
UVWXYZ.,-/
abcdefghij
klmnopqrst
uvwxyz#&:*
TIME BASE
INTERNAL CLOCK
12 HOUR
EVENT TYPE
ALL EVENTS
EVENT LABEL
EVENT01
TIME FORMAT
SET TIME
EVENT LABEL
NEW
12:00 AM
EVENT ACTIVE
EVENT TIME
EVENT OCCURS
SUNDAY
ON
12:00 AM
DATE FORMAT
SET DATE
DAYLIGHT SAVINGS
MM/DD/YYYY
00/00/0000
OFF
<EDIT EVENT LABEL>
<EDIT EVENT>
<CLEAR EVENT>
<LIST EVENT>
ON
MONDAY
ON
TUESDAY
ON
HOLIDAY
WEDNESDAY
THURSDAY
FRIDAY
ON
<EDIT HOLIDAY>
<CLEAR HOLIDAY>
<LIST HOLIDAYS>
ON
ON
ON
SATURDAY
HOLIDAY
SKIP HOLIDAYS
EVENT TYPE
PRESET
C3412M-D (12/08)
31
Download from Www.Somanuals.com. All Manuals Search And Download.
35X LowLight Day/Night Menu Tree
SPECTRA IV
LANGUAGE
ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
SYSTEM INFORMATION
DISPLAY SETUP
SERIAL #
XXXXXXXXXXXXXX
XX-XXXX
PRESET LABEL
2 (SECS)
2 (SECS)
2 (SECS)
2 (SECS)
OFF
DOME DRIVE MODEL
BACK BOX MEMORY
SOFTWARE VERSION
BUILD
ZONE LABEL
ZOOM
AVAILABLE
XX.X
AZIMUTH/ELEVATION
DIRECTION
FONT VERSION
COMM
XX.X
ALARM MESSAGE
DATE/TIME
2 (SECS)
ON
XXXXXXXXXX
D ADDRESS
1
2
EVENT LABEL
2 (SECS)
P ADDRESS
CM95OO MODE
32 PRESETS
OFF
OFF
C
<LABEL POSITIONS>
RESTORE FACTORY DEFAULTS
PROTOCOL
DIPSWITCH INFORMATION
PRESSURIZED*
<ADDITIONAL>
X.XX
LABEL POSITION
12345678
1234567890
SW1[--------] SW2[----------]
[ZONE LABEL-------]
[PRESET LABEL-------]
[ALARM 1-------]
ADDITIONAL
SW1 1-8:
D ADDRESS 1
FREE MEMORY
LATEST RESET
AZIMUTH ZERO OFFSET
MOTOR ACTIVE
CAMERA ACTIVE
VIDEO LEVEL
XXXXXX
POWER ON
0°
[ALERT MESSAGE---]*
P ADDRESS 1
SW2 1 : 32 PRESETS. OFF
SW2 2 : CM9500 MODE. OFF
SW2 3 : COAX SPIV
SW2 4-5 : RS422 <->
SAVE AND EXIT
CANCEL AND EXIT
HELP
YES
YES
NORMAL
XXXX-XXXX
ENGLISH X.XX
XXX/-XX
SW2 6-8 : COMM. 2400.N.8.1
SW2 9 : UTC SOURCE. COAX
SW2 10 : TX/RX TERM.. OFF
CAMERA MODEL
LANGUAGE 1
NE
XXX.XX
. . .
LANGUAGE 10
ITALIANO X.XX
PRESS IRIS OPEN TO CONTINUE
<DIPSWITCH INFORMATION>
CAMERA
ADVANCED SETTINGS
MOTION
POWER UP
TYPE OF LIGHTING
AUTO FOCUS
T1
ON
SUTTER SPEED
AGC LIMIT
AUTO
28
AUTO FLIP
ON
ON
POWER UP ACTION
AUTO
PROPORTIONAL PAN
PARK TIME (MINUTES)
PARK ACTION
SURE FOCUS
OFF
AUTO IRIS
AUTO
66
0
ZOOM LIMIT
XXXX
XXXX
XXXXXX
XXXX
OFF
AUTO IRIS LEVEL
AUTO IRIS PEAK
AUTO SHARPNESS
SHARPNESS LEVEL
AUTO WHITE BALANCE
R GAIN
NONE
25
AUTO
ON
ZOOM SPEED
8
ON
26
ON
255
255
OFF
HIGH
SCAN SPEED DEG/S
PRESET FREEZE FRAME
LIMIT STOPS
<SET MANUAL STOPS>
<CLEAR MANUAL STOPS>
<SET SCAN STOPS>
<CLEAR SCAN STOPS>
<SET AZIMUTH ZERO>
<CLEAR AZIMUTH ZERO>
LOW LIGHT LIMIT
IR CUT FILTER
LOW LIGHT FOCUS
AUTO IR LEVEL
<ADVANCED SETTINGS>
AUTO
B GAIN
BACKLIGHT COMP
VIDEO LEVEL
SENSOR SCAN MODE
FIELD ALIGN
PROGRESSIVE
OFF
E. IMAGE STABILIZER
IMAGE ENHANCEMENT
OFF
DEFAULT
LOW LUX NOISE REDUCTION
ON
WIDE DYNAMIC RANGE
OFF
ZONES
WINDOW BLANKING
SET WINDOWS
ZONE NUMBER
1
STYLE
GRAY
OFF
OFF
WINDOW NUMBER
<EDIT WINDOW LOCATION>
<EDIT WINDOW ZOOM>
<EDIT SCHEDULE>
ENABLE WINDOW
REVERSE
1
***ZONE NOT DEFINED***
<EDIT ZONE LABEL>
<EDIT ZONE>
BLANK ALL ABOVE
BLANK ALL BELOW
<SET WINDOWS>
NO
ZONE ENABLED
ZONE BLANKING
<CLEAR ZONE>
ON
OFF
CLEAR WINDOW
ALERT*
REPEAT
CURRENT READING
CLEAR
PASSWORD
CONSTANT
TEMPERATURE
DEWPOINT
PRESURE
CLEAR ALL ZONES
ENABLE PASSWORD
<EDIT PASSWORD>
OFF
ACK ACTION
ALWAYS ON
CLEAR ALL PRESETS
CLEAR ALL PATTERNS
ACTIVATE AUX
<CURRENT READING>
RESET ALERT
NO
REFRESH
CLEAR ALL WINDOW BLANKING
CLEAR ALL EVENTS
RESTORE FACTORY DEFAULTS
*This setting applies only to Pressurized Spectra IV dome systems. Spectra IV systems that are not pressurized will not display this menu item.
32
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
LINE SYNC
PRESETS
EDIT DETECTION AREAS
PATTERNS
LINE SYNC
LINE SYNC PHASE
ON
0
PRESET NUMBER
DETECTION AREA 1
PATTERN NUMBER
1
***PRESET NOT DEFINED***
<EDIT PRESET LABEL>
<EDIT PRESET SCENE>
<EDIT CAMERA SETTINGS>
<MOTION DETECTION>
<EDIT SCHEDULE>
LOCATION
SENSITIVITY
0
<PROGRAM PATTERN>
<CLEAR PATTERN>
<EDIT SCHEDULE>
MEDIUM
DETECTION AREA 2
LOCATION
0
SENSITIVITY
MEDIUM
REFERENCE INFO
PATTERN USAGE
REMAINING
0%
100%
DETECTION AREA 3
LOCATION
<CLEAR PRESET>
0
<CLEAR CAMERA SETTINGS>
REFERENCE INFORMATION
AZIMUTH
SENSITIVITY
MEDIUM
DETECTION AREA 4
LOCATION
0
ELEVATION
SENSITIVITY
MEDIUM
ZOOM
CUSTOM CAMERA SETTINGS
ALARMS
ALARM SETTINGS
AUX
TITLE TEXT
RESUME
OFF
5
0
ALARM NUMBER
ALARM PRIORITY
ALARM ACTION
ACTIVATE AUX
ALARM CONTACT
<EDIT SCHEDULE>
1
LOW
NONE
NO
AUX 1 MODE
TOGGLE
ENABLE TITLE TEXT
<EDIT TITLE TEXT>
SEQUENCE (SECS)
RESET DELAY (SECS)
<ALARM SETTINGS>
DWELL TIME (SECS)
AUX 2 MODE
1
TOGGLE
1
DWELL TIME (SECS)
<EDIT SCHEDULE>
N/O
EDIT EVENT
EVENT LABEL
EVENT01
EDIT THE PASSWORD
CLOCK
EVENT
EVENT ACTIVE
EVENT TIME
EVENT OCCURS
SUNDAY
ON
12:00 AM
1234567890
ABCDEFGHIJ
KLMNOPQRST
UVWXYZ.,-/
abcdefghij
klmnopqrst
uvwxyz#&:*
TIME BASE
INTERNAL CLOCK
12 HOUR
EVENT TYPE
ALL EVENTS
TIME FORMAT
SET TIME
EVENT LABEL
NEW
ON
12:00 AM
MONDAY
ON
DATE FORMAT
SET DATE
MM/DD/YYYY
00/00/0000
OFF
<EDIT EVENT LABEL>
<EDIT EVENT>
TUESDAY
ON
WEDNESDAY
THURSDAY
FRIDAY
ON
DAYLIGHT SAVINGS
<CLEAR EVENT>
<LIST EVENT>
ON
ON
ON
SATURDAY
HOLIDAY
HOLIDAY
SKIP HOLIDAYS
<EDIT HOLIDAY>
<CLEAR HOLIDAY>
<LIST HOLIDAYS>
EVENT TYPE
PRESET
C3412M-D (12/08)
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Language
The language for the on-screen menus is selectable. Available languages include English,
Spanish, French, German, Italian, Portuguese, Russian, Polish, Turkish, and Czech. The factory
default language is English.
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
To change the display language:
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
1. Use the joystick to position the cursor beside LANGUAGE.
2. Press Iris Open. The cursor moves to the right, beside the current, selected language.
EXIT
3. Move the joystick up or down to view selections. Press Iris Open to enter selection.
All on-screen menus are changed to the selected language.
*This setting applies only to Pressurized Spectra IV dome systems.
34
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
System Information
The System Information menu displays the dome drive model, software version, available
SPECTRA IV
memory, DIP switch information, and other diagnostic information.
System settings cannot be changed using this menu; this information is for reference only.
Use the following steps to display the System Information menu:
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
1. Use the joystick to position the cursor beside SYSTEM INFORMATION.
2. Press Iris Open. The SYSTEM INFORMATION menu opens.
EXIT
DIP SWITCH INFORMATION
SYSTEM INFORMATION
SERIAL #
The DIP Switch Information menu displays the dome drive’s current DIP switch settings. This
provides a way to remotely view the DIP switch settings without removing the dome drive from
the back box.
DOME DRIVE MODEL
BACK BOX MEMORY
SOFTWARE VERSION
BUILD
FONT VERSION
DIP SWITCH INFORMATION
COMM
12345678
1234567890
D ADDRESS
P ADDRESS
CM9500 MODE
32 PRESETS
PROTOCOL
SW1[- - - - - - - -] SW2[- - - - - - - - - -]
SW1 1-8 :
D ADDRESS 1
P ADDRESS 1
PRESSURIZED*
<ADDITIONAL>
SW2 1 : 32 PRESETS. OFF
SW2 2 : CM9500 MODE. OFF
SW2 3 : COAX SPIV
SW2 4-5 : RS422 <->
BACK
EXIT
SW2 6-8 : COMM. 2400.N.8.1
SW2 9 : UTC SOURCE. COAX
SW2 10 : TX/RX TERM.. OFF
PRESS IRIS OPEN TO CONTINUE
ADDITIONAL
FREE MEMORY
LAST RESET
AZIMUTH ZERO OFFSET
MOTOR ACTIVE
CAMERA ACTIVE
VIDEO LEVEL
CAMERA MODEL
LANGUAGE 1
LANGUAGE 2
LANGUAGE 3
LANGUAGE 4
LANGUAGE 5
LANGUAGE 6
LANGUAGE 7
LANGUAGE 8
LANGUAGE 9
LANGUAGE 10
<DIPSWITCH INFORMATION>
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
C3412M-D (12/08)
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Display Setup
Display setup allows you to program how labels are displayed on the monitor. The following
labels are available:
SPECTRA IV
LANGUAGE
PRESET LABEL: Identifies preset.
ZONE LABEL: Identifies zone.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
ZOOM: Identifies the amount of magnification.
AZIMUTH1/ELEVATION2: Amount of pan from zero degrees vertical and the amount of tilt from
zero degrees horizontal.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
EXIT
DIRECTION: Displays compass direction.
ALARM MESSAGE: Displays activated alarm.
DATE/TIME: Displays current date and time.
EVENT LABEL: Displays activated event.
DISPLAY SETUP
PRESET LABEL
ZONE LABEL
A preset label is displayed when a preset is called. A zone label is displayed when the system
moves into a zone. The zoom ratio label is displayed when zoom is activated. Azimuth/elevation
and direction labels are displayed when pan/tilt is activated. An alarm message appears on the
monitor when an alarm occurs. An event label appears on the monitor when an event occurs.
ZOOM
AZIMUTH/ELEVATION
DIRECTION
ALARM MESSAGE
DATE/TIME
EVENT LABEL
<LABEL POSITIONS>
RESTORE FACTORY DEFAULTS
The following settings are available for each label except date and time:
OFF: Label is not displayed when activated.
BACK
EXIT
CONSTANT: The label is continually displayed when activated.
2 SECONDS: The label is displayed for 2 seconds after activation.
5 SECONDS: The label is displayed for 5 seconds after activation.
10 SECONDS: The label is displayed for 10 seconds after activation.
The settings for date and time are ON or OFF.
1 Azimuth is the pan angle from zero to 359 degrees.
2 Elevation is the tilt position from zero (horizon) to -90 degrees.
*This setting applies only to Pressurized Spectra IV dome systems.
36
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
LABEL POSITIONS
Labels can be placed anywhere on the monitor. This feature allows you to customize the
appearance of your monitor screen.
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
The following labels are not set at fixed positions:
PRESET LABEL
ZONE LABEL
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
ALARM 1
EXIT
ZOOM RATIO - XXX.XX
AZIMUTH1/ELEVATION2 - XXX°/-XX°
DIRECTION - NE
DISPLAY SETUP
ALERT MESSAGE3*
PRESET LABEL
ZONE LABEL
TITLE TEXT
ZOOM
AZIMUTH/ELEVATION
DIRECTION
EVENT LABEL
ALARM MESSAGE
DATE/TIME
To set a label position:
EVENT LABEL
<LABEL POSITIONS>
RESTORE FACTORY DEFAULTS
BACK
EXIT
1. Use the joystick to position the cursor beside a label.
2. Press Iris Open.
3. Use the joystick to move the label up, down, left, or right.
4. Press Iris Open.
LABEL POSITION
5. Repeat steps 1–4 to position other labels.
6. Position the cursor next to Save and Exit. Press Iris Open to save settings and exit the menu.
[ZONE LABEL-------]
[PRESET LABEL-------]
[ALARM 1-------]
[EVENT-------]
[ALERT MESSAGE-------]*
<TITLE TEXT>
SAVE AND EXIT
CANCEL AND EXIT
HELP
XXXo/-XXXo
NE
XXX.XX
XX/XX/YYYY 00:00
1 Azimuth is the pan angle from zero to 359 degrees.
2 Elevation is the tilt position from zero (horizon) to -90 degrees.
3 The alert message is the warning displayed on the monitor if pressure, temperature, or dew point inside the
dome reach unacceptable levels.
*This setting applies only to Pressurized Spectra IV dome systems.
C3412M-D (12/08)
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Dome Settings
CAMERA
TYPE OF LIGHTING
(Does not apply to 16X or 18X models.)
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
Pelco has calibrated settings that optimize the white balance and the picture for several lighting
conditions. There are three settings:
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
T1 (default): For use in outdoor applications.
T2: For use in indoor applications.
EXIT
T3: (Available only with 23X models.) For use in applications that use sodium lighting.
AUTO FOCUS
DOME SETTINGS
Auto focus allows the lens to remain in focus during zoom-in, zoom-out, and motion functions.
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
There are two auto focus settings:
ON (default): If auto focus mode is set to ON, the camera will focus automatically when using
pan, tilt, and zoom (PTZ) functions.
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
BACK
EXIT
OFF: Focus is operated manually. To focus, press the Focus Far or Focus Near button on the
controller.
Sure Focus
When sure focus is enabled and all PTZ motions are stopped, the camera will attempt to find a
fixed focus position and lock to an object in the scene. If a focus lock is acquired or a specific
amount of time has expired with no focus lock, the focus position remains fixed until PTZ is
resumed.
CAMERA
TYPE OF LIGHTING
AUTO FOCUS
SURE FOCUS
ZOOM LIMIT
ZOOM SPEED
LOW LIGHT LIMIT
IR CUT FILTER
LOW LIGHT FOCUS
AUTO IR LEVEL
<ADVANCED SETTINGS>
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
38
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
ZOOM LIMIT
SPECTRA IV
LANGUAGE
Zoom limit allows the user to define a limitation on the amount of telephoto zoom. The settings
vary depending on camera model.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
16X (Models DD4TC16 and DD4TC16-X)
The default setting is 32X. Cameras with 128X zoom (16X optical zoom and 8X digital zoom) can
be set for 16X, 32X, 64X, or 128X.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
EXIT
18X (Models DD4CBW18 and DD4CBW18-X)
The default setting is 32X. Cameras with 216X zoom (18X optical zoom and 12X digital zoom) can
be set for 18X, 32X, 72X, or 144X, 180X, or 216X.
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
22X (Models DD4C22, and DD4C22-X)
The default setting is 32X. Cameras with 264X zoom (22X optical zoom and 12X digital zoom) can
be set for 22X, 32X, 88X, 176X, 220X, or 264X.
23X (Models DD4CBW23 and DD4CBW23-X)
The default setting is 32X. Cameras with 276X zoom (23X optical zoom and 12X digital zoom) can
be set for 23X, 32X, 92X, 184X, 230X, 276X.
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
BACK
EXIT
35X (Models DD4CBW35 and DD4CBW35-X)
The default setting is 70X. Cameras with 420X zoom (35X optical zoom and 12X digital zoom) can
be set for 35X, 70X, 140X, 280X, 350X, or 420X.
CAMERA
TYPE OF LIGHTING
AUTO FOCUS
SURE FOCUS
ZOOM LIMIT
ZOOM SPEED
LOW LIGHT LIMIT
IR CUT FILTER
LOW LIGHT FOCUS
AUTO IR LEVEL
<ADVANCED SETTINGS>
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
C3412M-D (12/08)
39
Download from Www.Somanuals.com. All Manuals Search And Download.
ZOOM SPEED
SPECTRA IV
LANGUAGE
Zoom speed allows the user to define how fast the dome will go from full wide zoom to the 16X,
18X, 22X, 23X, or 35X optical zoom.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
Available zoom speed settings for 16X models include:
HIGH: 1.9 seconds
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
MEDIUM (default): 3.6 seconds
LOW: 6.0 seconds
EXIT
Available zoom speed settings for 18X and 23X models include:
HIGH: 2.9 seconds
DOME SETTINGS
MEDIUM (default): 4.2 seconds
LOW: 5.8 seconds
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
Available zoom speed settings for 22X models include:
HIGH: 2.4 seconds
MEDIUM (default): 3.9 seconds
LOW: 6.3 seconds
<TITLE TEXT>
<ALERT>*
<CLEAR>
Available zoom speed settings for 35X models include:
HIGH: 3.2 seconds
<PASSWORD>
<CLOCK>
<EVENT>
BACK
EXIT
MEDIUM (default): 4.6 seconds
LOW: 6.6 seconds
Note: When using the HIGH setting, the image may be out of focus until zooming stops.
CAMERA
LOW LIGHT LIMIT
Low light limit is the maximum duration, in fractions of a second, that the electronic shutter will
remain open in low light conditions. The default setting is 2.
TYPE OF LIGHTING
AUTO FOCUS
SURE FOCUS
ZOOM LIMIT
ZOOM SPEED
LOW LIGHT LIMIT
IR CUT FILTER
LOW LIGHT FOCUS
AUTO IR LEVEL
Settings include the following:
2 = 1/2 second
4 = 1/4 second
8 = 1/8 second
30 = 1/30 second
60 = 1/60 second
<ADVANCED SETTINGS>
15 = 1/15 second
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
40
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
IR CUT FILTER
(Applies only to 18X, 23X, and 35X models.)
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
The 18X, 23X, and 35X cameras have two modes of operation: color, and black-white. You can
increase sensitivity in low light conditions by switching to black-white mode (removing the IR cut
filter). Color mode is preferred in normal lighting conditions.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
The following are the settings for the IR cut filter:
EXIT
OFF: Manual operation is controlled by preset 88 (filter IN) and 89 (filter OUT).
AUTO (default): Automatic operation is controlled by the auto IR level setting.
IN: Images are always displayed in color mode.
DOME SETTINGS
OUT: Images are always displayed in black-white mode.
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
Note: The IN and OUT settings are only available when editing camera settings through the
Low Light Focus
If you are using an IR illuminator, the low light focus feature of the camera can be tuned to
correspond to the setting of the illuminator.
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
There are three low light focus settings:
OFF (default): Low light focus is not activated.
850NM: Low light focus is tuned to 850 nm (nanometers).
950NM: Low light focus is tuned to 950 nm.
BACK
EXIT
CAMERA
Auto IR Level
TYPE OF LIGHTING
AUTO FOCUS
The auto IR level is the light level at which the infrared filter switches IN or OUT.
SURE FOCUS
ZOOM LIMIT
ZOOM SPEED
Following are the available settings for the auto IR level:
LOW LIGHT LIMIT
IR CUT FILTER
LOW LIGHT FOCUS
AUTO IR LEVEL
DUSK (default): Approximately 6 lux (black-white); approximately 13 lux (color).
DARK: Approximately 0.1 lux (black-white); approximately 2 lux (color).
<ADVANCED SETTINGS>
Notes:
BACK
EXIT
• If backlight compensation is ON and the IR cut filter switches OUT in normal lighting
conditions, adjust the Auto IR Level to a darker setting. Refer to Backlight Compensation (BLC)
• Low light does not mean no light. Some type of illumination is required (street light, IR light,
etc.). The camera is not sensitive to IR light when the IR cut filter is IN.
*This setting applies only to Pressurized Spectra IV dome systems.
C3412M-D (12/08)
41
Download from Www.Somanuals.com. All Manuals Search And Download.
ADVANCED CAMERA SETTINGS
SHUTTER SPEED
SPECTRA IV
LANGUAGE
Shutter speed is the duration of the electronic shutter. Program shutter speed to operate
automatically (Auto) or manually (Numeric Value).
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
AUTO (default): The electronic shutter speed is set automatically by the amount of light sensed
by the camera.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
NUMERIC VALUE: Spectra IV/Spectra IV SE dome systems have several numerical shutter
speed settings. The higher the number, the faster the electronic shutter.
EXIT
The slowest shutter speed setting is 2 = 1/2 second.
The fastest setting is 30,000 = 1/30,000 second.
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
Increasing the shutter speed lowers the light sensitivity and reduces the streaking of fast moving
objects.
Set the shutter speed to 100 if you are using an NTSC camera in a 50 Hz environment. This will
eliminate any flicker that may occur in the picture.
<TITLE TEXT>
<ALERT>*
AGC LIMIT
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
AGC limit allows users to adjust how the system balances AGC (automatic gain control) and
electronic shutter in low light conditions. As scene lighting decreases, the system will
automatically adjust, adding a mixture of AGC and slow shutter according to the AGC limit
setting. AGC limit can be set between 0 and 40, with 40 applying maximum AGC before slow
shutter. In contrast, setting AGC limit to 0 will force the system software to apply maximum slow
shutter (as defined by the low light limit setting) before any AGC is applied. The default AGC
settings vary depending on camera model.
BACK
EXIT
CAMERA
TYPE OF LIGHTING
AUTO FOCUS
SURE FOCUS
ZOOM LIMIT
ZOOM SPEED
LOW LIGHT LIMIT
IR CUT FILTER
LOW LIGHT FOCUS
AUTO IR LEVEL
Note: The maximum slow shutter that the system will achieve is 1/2 second shutter (refer to
<ADVANCED SETTINGS>
BACK
EXIT
ADVANCED SETTINGS
SHUTTER SPEED
AGC LIMIT
AUTO IRIS
AUTO IRIS LEVEL
AUTO IRIS PEAK
AUTO SHARPNESS
SHARPNESS LEVEL
AUTO WHITE BALANCE
R GAIN
B GAIN
BACKLIGHT COMP
VIDEO LEVEL
SENSOR SCAN MODE
FIELD ALIGN
E. IMAGE STABILIZER
IMAGE ENHANCEMENT
LOW LUX NOISE REDUCTION
WIDE DYNAMIC RANGE
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
42
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
AUTO IRIS
SPECTRA IV
LANGUAGE
Auto iris is the lens function that automatically opens and closes the iris in response to changing
light conditions.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
Program the auto iris to operate automatically or at a user-defined level.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
OFF: Auto iris is disabled, and control is always manual.
AUTO (default): The iris is adjusted automatically to produce a constant video output as
determined by the auto iris level setting.
EXIT
If auto iris is in the auto mode, it will remain that way until the iris is manually opened or closed.
The dome will return to auto mode when it is panned or tilted more than 15 degrees.
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
Auto Iris Level
Auto iris level is the numeric value the auto iris uses to maintain the brightness level of the
camera. Increase the value to brighten the scene. Decrease the value to darken the scene.
This setting can be adjusted if the video level in the auto iris mode is too bright or too dark.
<TITLE TEXT>
<ALERT>*
Note: If backlight compensation is ON, decrease the auto iris level setting.
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
BACK
EXIT
Auto Iris Peak
Increasing the peak value will cause the auto iris circuit to react more to highlights or “peaks” in
the picture. Decreasing this value will cause it to use the average video level to adjust the iris.
CAMERA
TYPE OF LIGHTING
AUTO FOCUS
SURE FOCUS
ZOOM LIMIT
ZOOM SPEED
LOW LIGHT LIMIT
IR CUT FILTER
LOW LIGHT FOCUS
AUTO IR LEVEL
<ADVANCED SETTINGS>
BACK
EXIT
ADVANCED SETTINGS
SHUTTER SPEED
AGC LIMIT
AUTO IRIS
AUTO IRIS LEVEL
AUTO IRIS PEAK
AUTO SHARPNESS
SHARPNESS LEVEL
AUTO WHITE BALANCE
R GAIN
B GAIN
BACKLIGHT COMP
VIDEO LEVEL
SENSOR SCAN MODE
FIELD ALIGN
E. IMAGE STABILIZER
IMAGE ENHANCEMENT
LOW LUX NOISE REDUCTION
WIDE DYNAMIC RANGE
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
C3412M-D (12/08)
43
Download from Www.Somanuals.com. All Manuals Search And Download.
AUTO SHARPNESS
Auto sharpness enhances picture detail by increasing the aperture gain of the camera and
sharpening the edges in the picture.
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
There are two settings:
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
ON (default): The camera automatically maintains a normal sharpness mode.
OFF: The sharpness of the picture is set manually by programming the sharpness level.
Sharpness level settings range from 0–63.
EXIT
DOME SETTINGS
AUTO WHITE BALANCE
This feature automatically processes the viewed image to retain color balance over a color
temperature range. The default setting for auto white balance is ON.
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
R GAIN: Adjusts the picture output in the red range. As you change the value, you will see the
color change on your monitor.
B GAIN: Adjusts the picture output in the blue range. As you change the value, you will see the
color change on your monitor.
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
BACK
EXIT
CAMERA
TYPE OF LIGHTING
AUTO FOCUS
SURE FOCUS
ZOOM LIMIT
ZOOM SPEED
LOW LIGHT LIMIT
IR CUT FILTER
LOW LIGHT FOCUS
AUTO IR LEVEL
<ADVANCED SETTINGS>
BACK
EXIT
ADVANCED SETTINGS
SHUTTER SPEED
AGC LIMIT
AUTO IRIS
AUTO IRIS LEVEL
AUTO IRIS PEAK
AUTO SHARPNESS
SHARPNESS LEVEL
AUTO WHITE BALANCE
R GAIN
B GAIN
BACKLIGHT COMP
VIDEO LEVEL
SENSOR SCAN MODE
FIELD ALIGN
E. IMAGE STABILIZER
IMAGE ENHANCEMENT
LOW LUX NOISE REDUCTION
WIDE DYNAMIC RANGE
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
44
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
BACKLIGHT COMPENSATION (BLC)
SPECTRA IV
LANGUAGE
If a bright backlight is present, the subjects in the picture may appear dark or as a silhouette.
Backlight compensation enhances objects in the center of the picture. The dome uses the center
of the picture to adjust the iris. If there is a bright light source outside of this area, it will wash
out to white. The camera will adjust the iris so that the object in the sensitive area is properly
exposed.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
EXIT
There are two backlight compensation settings:
OFF (default): Backlight compensation is not activated.
ON: Backlight compensation is activated.
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
If backlight compensation is ON, decrease the auto iris level setting and adjust the auto IR level
VIDEO LEVEL
Set the video output to one of the following options:
NORMAL: 1.0 Vp-p.
HIGH (default setting): 1.2 Vp-p. to compensate for losses in video cable.
BACK
EXIT
CAMERA
TYPE OF LIGHTING
AUTO FOCUS
SURE FOCUS
ZOOM LIMIT
ZOOM SPEED
LOW LIGHT LIMIT
IR CUT FILTER
LOW LIGHT FOCUS
AUTO IR LEVEL
<ADVANCED SETTINGS>
BACK
EXIT
ADVANCED SETTINGS
SHUTTER SPEED
AGC LIMIT
AUTO IRIS
AUTO IRIS LEVEL
AUTO IRIS PEAK
AUTO SHARPNESS
SHARPNESS LEVEL
AUTO WHITE BALANCE
R GAIN
B GAIN
BACKLIGHT COMP
VIDEO LEVEL
SENSOR SCAN MODE
FIELD ALIGN
E. IMAGE STABILIZER
IMAGE ENHANCEMENT
LOW LUX NOISE REDUCTION
WIDE DYNAMIC RANGE
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
C3412M-D (12/08)
45
Download from Www.Somanuals.com. All Manuals Search And Download.
SENSOR SCAN MODE
(Applies only to 35X models.)
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
Sensor scan mode controls the internal processing of the camera's image sensor. The data
scanned from the image sensor at each field time is used for the internal image control
algorithms and digital signal processing (DSP).
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
Note: When changing from PROGRESSIVE to INTERLACED, or vice-versa, the camera restarts to
establish the new setting.
EXIT
There are two sensor scan modes:
DOME SETTINGS
PROGRESSIVE (default): Produces a higher quality image by using each line scanned from the
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
image sensor.
INTERLACED: Produces a slight increase in sensitivity by using blended data from pairs of lines
scanned from the image sensor.
When sensor scan mode is set to INTERLACED, the wide dynamic range and image enhancement
features are automatically disabled. There may be additional effects, such as a degradation of
the signal-to-noise ratio, degradation of the color reproduction, and a loss of motion detection for
presets configured with motion detection.
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
FIELD ALIGN
(Applies only to 18X, 23X, and 35X models.)
<EVENT>
BACK
EXIT
Field align determines whether the camera produces progressive segmented frame output (PsF)
or interlaced frame output. Analog video from the camera is always output in separate fields as
required for compatibility. This feature allows PsF to be recombined by an encoding device
without a time difference between fields, as is typically seen from interlaced analog video
output. Enabling field align requires that the encoding device you are using always combines the
odd and even fields in the specified order.
CAMERA
TYPE OF LIGHTING
AUTO FOCUS
SURE FOCUS
ZOOM LIMIT
ZOOM SPEED
LOW LIGHT LIMIT
IR CUT FILTER
LOW LIGHT FOCUS
AUTO IR LEVEL
There are three field alignment settings:
<ADVANCED SETTINGS>
BACK
EXIT
OFF (default): Field alignment is disabled. Use this setting if you are using an analog device/
system or a digital encoder that does not support PsF.
ODD: Arranges the odd field for a particular video frame before the even field for that frame.
EVEN: Arranges the even field for a particular video frame before the odd field for that frame.
Notes:
ADVANCED SETTINGS
SHUTTER SPEED
AGC LIMIT
AUTO IRIS
AUTO IRIS LEVEL
AUTO IRIS PEAK
AUTO SHARPNESS
SHARPNESS LEVEL
AUTO WHITE BALANCE
R GAIN
• If you enable field alignment by selecting ODD or EVEN, you must disable any deinterlacing
settings for the encoding device to achieve maximum resolution.
B GAIN
• The ODD and EVEN settings require that the sensor scan mode is set to PROGRESSIVE. If field
align is set to ODD or EVEN, the sensor scan mode automatically changes to PROGRESSIVE.
BACKLIGHT COMP
VIDEO LEVEL
SENSOR SCAN MODE
FIELD ALIGN
E. IMAGE STABILIZER
IMAGE ENHANCEMENT
LOW LUX NOISE REDUCTION
WIDE DYNAMIC RANGE
BACK
EXIT
46
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
ELECTRONIC IMAGE STABILIZATION
SPECTRA IV
LANGUAGE
(Applies only to 35X models.)
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
Electronic image stabilization is a feature of the camera that can compensate for some forms of
external influences. In all cases, care should be taken to make sure that any dome system is
mounted to a rigid location.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
EXIT
In the event that vibration is introduced to the dome system, a user can select one of the
electronic image stabilization settings in the menu. The available settings are OFF, 5 Hz, and
10 Hz. Users should apply each of the settings to the camera to see which one best addresses
the vibration that is affecting the video quality.
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
Electronic image stabilization will not correct for all ranges of vibration. If either of the settings
fails to eliminate the vibration seen in the video, other measures should be taken to isolate the
vibration or to seek a more rigid mounting location.
Notes:
<TITLE TEXT>
<ALERT>*
• When electronic image stabilization is applied, digital slow shutter and wide dynamic range
are disabled. Zoom, image resolution, and viewing angle are also limited when this feature
is activated.
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
BACK
EXIT
• Electronic image stabilization cannot be used while in a preset that has motion detection
activated.
CAMERA
TYPE OF LIGHTING
AUTO FOCUS
SURE FOCUS
ZOOM LIMIT
ZOOM SPEED
LOW LIGHT LIMIT
IR CUT FILTER
LOW LIGHT FOCUS
AUTO IR LEVEL
<ADVANCED SETTINGS>
BACK
EXIT
ADVANCED SETTINGS
SHUTTER SPEED
AGC LIMIT
AUTO IRIS
AUTO IRIS LEVEL
AUTO IRIS PEAK
AUTO SHARPNESS
SHARPNESS LEVEL
AUTO WHITE BALANCE
R GAIN
B GAIN
BACKLIGHT COMP
VIDEO LEVEL
SENSOR SCAN MODE
FIELD ALIGN
E. IMAGE STABILIZER
IMAGE ENHANCEMENT
LOW LUX NOISE REDUCTION
WIDE DYNAMIC RANGE
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
C3412M-D (12/08)
47
Download from Www.Somanuals.com. All Manuals Search And Download.
IMAGE ENHANCEMENT
(Applies only to 35X models.)
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
The image enhancement feature improves the definition of objects, lines, or text in high contrast
areas, making them appear sharper.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
There are two image enhancement settings:
DEFAULT: Image enhancement is not activated.
ENHANCED: Image enhancement is activated.
EXIT
DOME SETTINGS
Warning: When using this feature be aware that picture noise, although unnoticeable to
the eye, will increase and may cause compression rate changes in DVRs, NVRs, and
network devices.
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
LOW LUX NOISE REDUCTION
(Applies only to 18X and 23X models.)
<TITLE TEXT>
<ALERT>*
<CLEAR>
Low lux noise reduction helps to reduce video noise in low light scenes. When enabled, low lux
noise reduction is directly affected by the AGC settings for the dome system.
<PASSWORD>
<CLOCK>
<EVENT>
BACK
EXIT
The following are the low lux noise reduction settings:
ON (default): Low lux noise reduction is enabled. As the scene darkens and AGC increases, the
noise reduction effect automatically increases. As noise reduction increases, you may also notice
some afterimaging and a slight reduction in color saturation.
CAMERA
TYPE OF LIGHTING
AUTO FOCUS
SURE FOCUS
ZOOM LIMIT
OFF: Low lux noise reduction is disabled.
ZOOM SPEED
LOW LIGHT LIMIT
IR CUT FILTER
LOW LIGHT FOCUS
AUTO IR LEVEL
<ADVANCED SETTINGS>
BACK
EXIT
ADVANCED SETTINGS
SHUTTER SPEED
AGC LIMIT
AUTO IRIS
AUTO IRIS LEVEL
AUTO IRIS PEAK
AUTO SHARPNESS
SHARPNESS LEVEL
AUTO WHITE BALANCE
R GAIN
B GAIN
BACKLIGHT COMP
VIDEO LEVEL
SENSOR SCAN MODE
FIELD ALIGN
E. IMAGE STABILIZER
IMAGE ENHANCEMENT
LOW LUX NOISE REDUCTION
WIDE DYNAMIC RANGE
BACK
EXIT
48
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
WIDE DYNAMIC RANGE
(Applies only to 23X and 35X models.)
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
Wide dynamic range (WDR) balances the brightest and darkest sections of a scene to produce a
picture that is better balanced in lighting and provides more detail.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
Available settings are OFF and ON; the default setting is OFF. When wide dynamic range is set to
ON the frame rate is reduced from the standard 30–15 frames per second (fps). Also, when this
setting is ON the iris will not close completely, even in manual mode.
EXIT
Note: Wide dynamic range is disabled when electronic image stabilization is set to 5 Hz or 10 Hz.
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
BACK
EXIT
Wide Dynamic Range ON
Wide Dynamic Range OFF
CAMERA
TYPE OF LIGHTING
AUTO FOCUS
SURE FOCUS
ZOOM LIMIT
ZOOM SPEED
LOW LIGHT LIMIT
IR CUT FILTER
LOW LIGHT FOCUS
AUTO IR LEVEL
<ADVANCED SETTINGS>
BACK
EXIT
ADVANCED SETTINGS
SHUTTER SPEED
AGC LIMIT
AUTO IRIS
AUTO IRIS LEVEL
AUTO IRIS PEAK
AUTO SHARPNESS
SHARPNESS LEVEL
AUTO WHITE BALANCE
R GAIN
B GAIN
BACKLIGHT COMP
VIDEO LEVEL
SENSOR SCAN MODE
FIELD ALIGN
E. IMAGE STABILIZER
IMAGE ENHANCEMENT
LOW LUX NOISE REDUCTION
WIDE DYNAMIC RANGE
BACK
EXIT
C3412M-D (12/08)
49
Download from Www.Somanuals.com. All Manuals Search And Download.
MOTION SETTINGS
AUTO FLIP
SPECTRA IV
LANGUAGE
When the camera tilts downward and goes just beyond the vertical position, the dome rotates
180 degrees. When the dome rotates (flips), the camera starts moving upward as long as you
continue to hold the joystick in the down position. Once you let go of the joystick after the dome
rotates, joystick control returns to normal operation. The auto-flip feature is useful for following a
person who passes directly beneath the dome.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
There are two auto flip modes:
EXIT
ON (default): Auto flip mode is enabled.
OFF: Auto flip mode is disabled.
DOME SETTINGS
PROPORTIONAL PAN
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
Proportional pan automatically reduces or increases the pan and tilt speeds in proportion to the
amount of zoom. At telephoto zoom settings, the pan and tilt speeds will be slower for a given
amount of joystick deflection than at wide zoom settings. This keeps the image from moving too
fast on the monitor when there is a large amount of zoom.
There are three proportional pan modes:
ON (default): Enables the proportional pan mode.
OFF: Disables proportional pan mode. The pan speed will not depend on the amount of zoom.
2X: Increases the speed of the proportional pan mode to twice that used when proportional pan
is set to ON.
BACK
EXIT
MOTION
AUTO FLIP
PROPORTIONAL PAN
PARK TIME (MINUTES)
PARK ACTION
SCAN SPEED (DEG/S)
PRESET FREEZE FRAME
LIMIT STOPS
<SET MANUAL STOPS>
<CLEAR MANUAL STOPS>
<SET SCAN STOPS>
<CLEAR SCAN STOPS>
<SET AZIMUTH ZERO>
<CLEAR AZIMUTH ZERO>
BACK
EXIT
REFERENCE INFORMATION
MANUAL LIMITS SET
SCAN LIMITS SET
*This setting applies only to Pressurized Spectra IV dome systems.
50
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
PARK TIME
SPECTRA IV
LANGUAGE
This feature allows the dome to begin a specified operation (scan, preset, or pattern) after a
programmed time of inactivity.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
Park time can be programmed from 1–720 minutes (12 hours), or set to zero, which disables this
feature. The default setting is zero.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
EXIT
Park Action
This feature will define the activity when the dome parks. The following settings are available:
NONE (default): No action.
DOME SETTINGS
AUTO SCAN: Dome starts auto scan operation.
RANDOM SCAN: Dome starts random scan operation.
FRAME SCAN: Dome starts frame scan operation.
PRESET 1: Dome goes to preset 1.
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
PRESET 8: Dome goes to preset 8.
PATTERN 1: Dome runs pattern 1.
<TITLE TEXT>
<ALERT>*
PATTERN 2: Dome runs pattern 2.
<CLEAR>
PATTERN 3: Dome runs pattern 3.
<PASSWORD>
<CLOCK>
<EVENT>
PATTERN 4: Dome runs pattern 4.
BACK
EXIT
PATTERN 5: Dome runs pattern 5.
PATTERN 6: Dome runs pattern 6.
PATTERN 7: Dome runs pattern 7.
PATTERN 8: Dome runs pattern 8.
MOTION
(Only 22X, 23X, and 35X models allow PATTERN 2 through PATTERN 8.)
AUTO FLIP
PROPORTIONAL PAN
PARK TIME (MINUTES)
PARK ACTION
SCAN SPEED (DEG/S)
PRESET FREEZE FRAME
LIMIT STOPS
<SET MANUAL STOPS>
<CLEAR MANUAL STOPS>
<SET SCAN STOPS>
<CLEAR SCAN STOPS>
<SET AZIMUTH ZERO>
<CLEAR AZIMUTH ZERO>
BACK
EXIT
REFERENCE INFORMATION
MANUAL LIMITS SET
SCAN LIMITS SET
*This setting applies only to Pressurized Spectra IV dome systems.
C3412M-D (12/08)
51
Download from Www.Somanuals.com. All Manuals Search And Download.
SCAN SPEED
SPECTRA IV
LANGUAGE
Scan speed is the degrees per second that the dome will pan when in a scan mode. Scan speed is
adjustable from 1 to 40 degrees per second through the programming menu. The default setting
is 25 degrees per second.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
PRESET FREEZE FRAME
EXIT
This feature freezes the scene on the monitor when going to a preset. This allows for smooth
transition from one preset scene to another. Preset freeze frame also reduces bandwidth when
used with digital network systems such as PelcoNet™ and guarantees that blanked areas will not
be revealed when going to a preset.
DOME SETTINGS
There are three preset freeze frame settings:
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
ON: The image on the screen freezes when a preset is called. When the dome reaches the
preset, the image is unfrozen and the preset scene is displayed.
OFF: The image is never frozen.
AUTO (default): Freeze frame is turned on automatically if window blanking is ON. If window
blanking is OFF, freeze frame is off.
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
BACK
EXIT
MOTION
AUTO FLIP
PROPORTIONAL PAN
PARK TIME (MINUTES)
PARK ACTION
SCAN SPEED (DEG/S)
PRESET FREEZE FRAME
LIMIT STOPS
<SET MANUAL STOPS>
<CLEAR MANUAL STOPS>
<SET SCAN STOPS>
<CLEAR SCAN STOPS>
<SET AZIMUTH ZERO>
<CLEAR AZIMUTH ZERO>
BACK
EXIT
REFERENCE INFORMATION
MANUAL LIMITS SET
SCAN LIMITS SET
*This setting applies only to Pressurized Spectra IV dome systems.
52
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
LIMIT STOPS
SPECTRA IV
LANGUAGE
Limit stops are programmable stops that limit the pan range of the dome. There must be two
limits, a left and a right, to define an area.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
There are two types of limit stops:
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
MANUAL: A manual (joystick) pan operation stops when a limit stop is reached.
SCAN: The dome reverses direction during random, frame, or auto scanning when a limit stop
is reached.
EXIT
To set manual or scan stops:
1. Use the joystick to position the cursor beside SET MANUAL STOPS or SET SCAN STOPS.
2. Press Iris Open.
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
3. Follow the directions displayed on the monitor.
Note: In order for the manual or scan stops to work, the LIMIT STOPS option must be ON.
To clear manual or scan stops:
<TITLE TEXT>
<ALERT>*
1. Use the joystick to position the cursor beside CLEAR MANUAL STOPS or CLEAR SCAN
STOPS.
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
BACK
EXIT
2. Press Iris Open.
3. Follow the directions displayed on the monitor.
MOTION
AUTO FLIP
PROPORTIONAL PAN
PARK TIME (MINUTES)
PARK ACTION
SCAN SPEED (DEG/S)
PRESET FREEZE FRAME
LIMIT STOPS
<SET MANUAL STOPS>
<CLEAR MANUAL STOPS>
<SET SCAN STOPS>
<CLEAR SCAN STOPS>
<SET AZIMUTH ZERO>
<CLEAR AZIMUTH ZERO>
BACK
EXIT
REFERENCE INFORMATION
MANUAL LIMITS SET
SCAN LIMITS SET
*This setting applies only to Pressurized Spectra IV dome systems.
C3412M-D (12/08)
53
Download from Www.Somanuals.com. All Manuals Search And Download.
AZIMUTH ZERO
SPECTRA IV
LANGUAGE
Azimuth is the pan angle from zero to 359 degrees. Azimuth zero is the pan position you specify to
be the zero degree point. Azimuth zero is normally set to magnetic north. Once set, azimuth and
compass readings are based on the set Azimuth Zero point.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
To program azimuth zero:
1. Use the joystick to position the cursor beside SET AZIMUTH ZERO.
2. Press Iris Open.
EXIT
3. Follow the directions displayed on the monitor.
To clear azimuth zero:
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
1. Use the joystick to position the cursor beside CLEAR AZIMUTH ZERO.
2. Press Iris Open.
<WINDOW BLANKING>
<ALARMS>
<AUX>
3. Follow the directions displayed on the monitor.
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
BACK
EXIT
MOTION
AUTO FLIP
PROPORTIONAL PAN
PARK TIME (MINUTES)
PARK ACTION
SCAN SPEED (DEG/S)
PRESET FREEZE FRAME
LIMIT STOPS
<SET MANUAL STOPS>
<CLEAR MANUAL STOPS>
<SET SCAN STOPS>
<CLEAR SCAN STOPS>
<SET AZIMUTH ZERO>
<CLEAR AZIMUTH ZERO>
BACK
EXIT
REFERENCE INFORMATION
MANUAL LIMITS SET
SCAN LIMITS SET
*This setting applies only to Pressurized Spectra IV dome systems.
54
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER UP
POWER UP ACTION
SPECTRA IV
LANGUAGE
This setting defines a specific activity (scan, preset, pattern) to be performed in the event the
power to the dome is cycled.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
The following settings are available:
NONE: No action.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
AUTO (default): The dome resumes its prior activity or direction before the power outage.
AUTO SCAN: Dome starts auto scan operation.
RANDOM SCAN: Dome starts random scan operation.
FRAME SCAN: Dome starts frame scan operation.
PRESET 1: Dome goes to preset 1.
EXIT
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
PRESET 2: Dome goes to preset 2.
PRESET 3: Dome goes to preset 3.
PRESET 4: Dome goes to preset 4.
PRESET 5: Dome goes to preset 5.
PRESET 6: Dome goes to preset 6.
PRESET 7: Dome goes to preset 7.
PRESET 8: Dome goes to preset 8.
PATTERN 1: Dome runs pattern 1.
BACK
EXIT
PATTERN 2: Dome runs pattern 2.
PATTERN 3: Dome runs pattern 3.
PATTERN 4: Dome runs pattern 4.
PATTERN 5: Dome runs pattern 5.
POWER UP
PATTERN 6: Dome runs pattern 6.
POWER UP ACTION
PATTERN 7: Dome runs pattern 7.
BACK
EXIT
PATTERN 8: Dome runs pattern 8.
(Only 22X, 23X, and 35X models allow PATTERN 2 through PATTERN 8.)
*This setting applies only to Pressurized Spectra IV dome systems.
C3412M-D (12/08)
55
Download from Www.Somanuals.com. All Manuals Search And Download.
LINE SYNC
Line sync refers to a programmable function that allows you to synchronize all cameras within a
matrix system.
SPECTRA IV
LANGUAGE
Spectra IV and Spectra IV SE dome systems automatically sense V-Sync input. No line sync setup
is required for Pelco control systems that provide a V-Sync signal.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
For matrix systems that do not output V-Sync, there are two settings for line synchronization:
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
ON (default): Adjusts the phase of the line sync to synchronize input power. Line sync phase
settings range from zero to 359 degrees.
EXIT
OFF: The dome synchronizes to the internal clock.
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
BACK
EXIT
LINE SYNC
LINE SYNC
LINE SYNC PHASE
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
56
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
PRESETS
The model of the back box you are using limits the number of programmable presets that can be stored and retrieved in the
back box memory. If you are using an older model back box, you may program and use up to the maximum number of
presets available to the dome drive. However, if the dome drive is changed, the back box model will limit the number of
stored presets available to the new dome drive. Refer to the table below for more information.
Back Box Series
Model
Number of Stored Presets
Spectra
99
Spectra SE
Spectra III
Spectra IV
BB53
BB4
15
128
256
The Spectra IV dome system, which includes 16X and 18X models, has 128 preset positions. The programmable presets
are numbered 1–32, 35–82, and 100–150.
The Spectra IV SE dome system, which includes 22X, 23X, and 35X models, has 256 preset positions. The programmable
presets are numbered 1–32, 35–82, and 100–256.
Note: The number of available presets may be limited by the head-ins, controllers, and DVRs that are connected to your
dome system.
Each of the user-definable presets can be programmed to use pan, tilt, camera settings, and motion detection.
The following presets are predefined for specific functions:
Preset
33:
Action
Flip command. Pans the dome drive 180 degrees.
34:
Pan zero command. Directs the dome drive to the factory-determined zero reference point.
83–87:
88:
89:
90–91:
92–93:
94:
Reserved.
IR filter IN (color).
IR filter OUT (black-white).
Manual limit stops.
Scan limit stops.
Reserved.
95:
96:
Select main programming menu.
Stop a scan.
97:
98:
Random scanning.
Frame scanning.
99:
Start auto scanning
C3412M-D (12/08)
57
Download from Www.Somanuals.com. All Manuals Search And Download.
Note: For American Dynamics controllers with only 32 presets, switch SW2-1 on the dome drive
SPECTRA IV
to the ON position. When SW2-1 is ON, preset
LANGUAGE
99 becomes 32
98 becomes 31
97 becomes 30
96 becomes 29
95 becomes 28
93 becomes 26
92 becomes 25
91 becomes 24
90 becomes 23
89 becomes 22
88 becomes 21
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
EXIT
If the limit stops are turned off, presets 23–26 can be used as regular presets.
Use the following steps to program a preset.
DOME SETTINGS
1. Select the preset number:
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
a. Use the joystick to position the cursor beside PRESET NUMBER. Press Iris Open.
The cursor moves to the right.
b. Move the joystick up or down to view selections. Press Iris Open to enter selection.
2. Edit the preset label:
<TITLE TEXT>
<ALERT>*
a. Use the joystick to position the cursor beside EDIT PRESET LABEL.
b. Press Iris Open. The following appears on the monitor:
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
BACK
EXIT
LABEL FOR PRESET
PRESET NUMBER ------
1234567890
ABCDEFGHIJ
KLMNOPQRST
UVWXYZ.,-/
abcdefghij
OK
CANCEL
SPACE
BACKSPACE
PRESETS
klmnopqrst
uvwxyz*;:
PRESET NUMBER
1
* * * PRESET NOT DEFINED * * *
<EDIT PRESET LABEL>
<EDIT PRESET SCENE>
<EDIT CAMERA SETTINGS>
<MOTION DETECTION>
c. Use the joystick to position the cursor beside a character. Press Iris Open to enter
selection. To clear a character, position the cursor beside BACKSPACE, and then press
Iris Open.
<EDIT SCHEDULE>
<CLEAR PRESET>
<CLEAR CAMERA SETTINGS>
BACK
EXIT
d. When label is completed, move the cursor to OK. Press Iris Open to return to the
Preset menu.
REFERENCE INFORMATION
AZIMUTH
-
-
-
-
ELEVATION
ZOOM RATIO
3. Edit the preset scene:
CUSTOM CAMERA SETTINGS
a. Use the joystick to position the cursor beside EDIT PRESET SCENE.
b. Press Iris Open.
c. Follow the directions displayed on the monitor.
*This setting applies only to Pressurized Spectra IV dome systems.
58
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Edit preset camera settings:
SPECTRA IV
LANGUAGE
a. Use the joystick to position the cursor beside EDIT CAMERA SETTINGS.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
b. Press Iris Open. The EDIT CAMERA SETTINGS window appears on the monitor. Refer
camera settings.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
c. To edit the camera settings schedule, use the joystick to position the cursor beside
EDIT SCHEDULE. Press Iris Open.
EXIT
page 80) with the following exceptions. In the Edit Schedule menu, the event type
cannot be changed. Also, the Holiday feature cannot be accessed from the Edit
Schedule menu.
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
For instructions on changing the features in the Edit Schedule menu, refer to Edit
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
Notes:
• For 23X and 35X models, there are two additional options available for the IR cut filter that are
only available when programming a preset. The additional settings are IN and OUT. If the IR cut
filter is set to IN, the preset scene will be in color. If the IR cut filter is set to OUT, the preset
scene will be in black-white.
BACK
EXIT
• You can copy camera settings from one preset to another preset. To copy camera settings do
the following:
(1) Use the joystick to position the cursor beside COPY CAMERA SETTINGS.
(2) Press Iris Open. The cursor moves to the right.
PRESETS
(3) Move the joystick up or down to view selections. Press Iris Open to enter selection.
PRESET NUMBER
1
* * * PRESET NOT DEFINED * * *
<EDIT PRESET LABEL>
<EDIT PRESET SCENE>
<EDIT CAMERA SETTINGS>
<MOTION DETECTION>
<EDIT SCHEDULE>
<CLEAR PRESET>
<CLEAR CAMERA SETTINGS>
BACK
EXIT
REFERENCE INFORMATION
AZIMUTH
-
-
-
-
ELEVATION
ZOOM RATIO
CUSTOM CAMERA SETTINGS
*This setting applies only to Pressurized Spectra IV dome systems.
C3412M-D (12/08)
59
Download from Www.Somanuals.com. All Manuals Search And Download.
ENABLE MOTION DETECTION
(Applies only to 23X and 35X models.)
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
The following are the settings for motion detection:
OFF (default): Motion detection is turned off (disabled).
ON: Motion detection is turned on (enabled).
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
Note: Motion detection does not work if the shutter speed is set at less than 1/60 of a second.
EXIT
EDIT DETECTION AREAS
(Applies only to 23X and 35X models.)
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
Four motion detection areas can be defined for a preset. Use the following steps to edit motion
detection areas.
<WINDOW BLANKING>
<ALARMS>
<AUX>
1. Edit detection areas 1, 2, 3, or 4:
<TITLE TEXT>
<ALERT>*
<CLEAR>
a. Use the joystick to position the cursor beside EDIT DETECTION AREAS.
<PASSWORD>
<CLOCK>
b. Press Iris Open. The EDIT DETECTION AREAS programming window appears on the
monitor.
<EVENT>
BACK
EXIT
c. Use the joystick to position the cursor beside LOCATION for DETECTION AREA 1, 2, 3,
or 4.
PRESETS
d. Press Iris Open. The cursor moves to the right next to the number 0.
PRESET NUMBER
* * * PRESET NOT DEFINED * * *
<EDIT PRESET LABEL>
<EDIT PRESET SCENE>
<EDIT CAMERA SETTINGS>
<MOTION DETECTION>
e. Move the joystick up. A blue rectangle appears in the upper left-hand corner of the
screen.
<EDIT SCHEDULE>
f. Use the joystick to place the blue rectangle over the desired detection area.
g. Press Iris Open to make a selection.
<CLEAR PRESET>
<CLEAR CAMERA SETTINGS>
BACK
EXIT
REFERENCE INFORMATION
AZIMUTH
2. Set the sensitivity of the motion detection area:
ELEVATION
ZOOM RATIO
CUSTOM CAMERA SETTINGS
a. Position the cursor next to SENSITIVITY for DETECTION AREA 1, 2, 3, or 4.
b. Press Iris Open, the cursor moves to the right.
MOTION DETECTION
MOTION DETECTION ENABLED
<EDIT DETECTION AREAS>
ACTIVATE AUX
c. Use the joystick to select one of the following sensitivity levels:
HIGH: The sensitivity level is high.
MEDIUM (default): Average sensitivity.
LOW: The sensitivity level is low.
AUX TIME (SECS)
BACK
EXIT
d. Press Iris Open to make selection.
*This setting applies only to Pressurized Spectra IV dome systems.
60
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
EDIT DETECTION AREAS
DETECTION AREA 1
LOCATION
0
SENSITIVITY
MEDIUM
DETECTION AREA 2
LOCATION
SENSITIVITY
0
MEDIUM
DETECTION AREA 3
LOCATION
SENSITIVITY
0
MEDIUM
DETECTION AREA 4
LOCATION
0
SENSITIVITY
MEDIUM
BACK
EXIT
MOTION DETECTION AREAS
Note: Motion detection is not guaranteed to catch 100 percent of activity.
C3412M-D (12/08)
61
Download from Www.Somanuals.com. All Manuals Search And Download.
ACTIVATE AUX COMMAND
(Applies only to 23X and 35X models.)
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
Motion detection can be programmed to trigger an auxiliary command when motion is detected.
The following are the settings for ACTIVATE AUX:
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
OFF (default): Motion detection will not trigger an AUX command.
1: Triggers a command to AUX 1.
EXIT
2: Triggers a command to AUX 2.
DOME SETTINGS
AUX TIME
(Applies only to 23X and 35X models.)
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
Aux time is the length of time the auxiliary will remain on after motion is detected. Available
settings for AUX TIME are 1–60 seconds.
<TITLE TEXT>
<ALERT>*
<CLEAR>
EDIT SCHEDULE
the following exceptions. In the Edit Schedule menu, the event type cannot be changed. Also,
the Holiday feature cannot be accessed from the Edit Schedule menu.
<PASSWORD>
<CLOCK>
<EVENT>
BACK
EXIT
PRESETS
PRESET NUMBER
* * * PRESET NOT DEFINED * * *
<EDIT PRESET LABEL>
<EDIT PRESET SCENE>
<EDIT CAMERA SETTINGS>
<MOTION DETECTION>
<EDIT SCHEDULE>
<CLEAR PRESET>
<CLEAR CAMERA SETTINGS>
BACK
EXIT
REFERENCE INFORMATION
AZIMUTH
ELEVATION
ZOOM RATIO
CUSTOM CAMERA SETTINGS
MOTION DETECTION
MOTION DETECTION ENABLED
<EDIT DETECTION AREAS>
ACTIVATE AUX
AUX TIME (SECS)
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
62
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
PATTERNS
A pattern is a memorized, repeating series of pan, tilt, zoom, and preset functions that can be
recalled with a command from a controller or automatically by a programmed function (alarm,
park, event, or power-up).
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
Both 16X and 18X models have one user-defined pattern available. The 22X, 23X, and 35X models
can handle up to eight patterns. Pattern length is based upon memory usage rather than a fixed
amount of time. The complexity of a pattern will determine the amount of storage available to
program other patterns.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
EXIT
Note: In most cases, the memory available will allow for ample time to schedule typical
patterns. If the scheduled patterns are unusually lengthy or complex, there is a possibility that
there may not be enough remaining memory to program all eight patterns for the 22X, 23X, and
35X models.
DOME SETTINGS
To program a pattern:
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
1. Use the joystick to position the cursor beside PATTERN NUMBER. Press Iris Open.
The cursor moves to the right.
2. Move the joystick up or down to view selections. Press Iris Open to enter selection.
3. Use the joystick to position the cursor beside PROGRAM PATTERN.
4. Press Iris Open. The Patterns programming window appears on the monitor.
5. Follow the directions displayed on the monitor.
After a pattern is programmed, the remaining storage percentage is displayed on the screen.
This is the amount of memory available to program the remaining patterns.
BACK
EXIT
To clear a pattern:
1. Use the joystick to position the cursor beside CLEAR PATTERN.
2. Press Iris Open.
PATTERNS
PATTERN NUMBER
<PROGRAM PATTERN>
<CLEAR PATTERN>
<EDIT SCHEDULE>
3. Follow the directions displayed on the monitor.
To edit the pattern schedule:
BACK
EXIT
the following exceptions. In the Edit Schedule menu, the event type cannot be changed. Also,
the Holiday feature cannot be accessed from the Edit Schedule menu.
REFERENCE INFORMATION
PATTERN USAGE
REMAINING
Note: When programming one or more presets within a pattern, use the normal controller
commands to call a preset. Not all controllers can start all patterns. However, any of the patterns
can be automatically started with park, power-up, event, and alarm functions.
*This setting applies only to Pressurized Spectra IV dome systems.
C3412M-D (12/08)
63
Download from Www.Somanuals.com. All Manuals Search And Download.
ZONES
A zone is a pan area, defined by a left and right limit, on the 360-degree pan plane. The
Spectra IV and Spectra IV SE dome systems are capable of eight zones, each with a 20-character
label.
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
To program a zone:
1. Use the joystick to position the cursor beside ZONE NUMBER. Press Iris Open, and the
cursor moves to the right.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
2. Move the joystick up or down to view selections. Press Iris Open to enter selection.
3. Use the joystick to position the cursor beside EDIT ZONE.
EXIT
4. Press Iris Open. The Zone programming window appears on the monitor.
5. Follow the directions displayed on the monitor. After the left and right limit stops are set,
the Zones menu reappears with the ZONE ENABLED option set to YES.
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
To edit a zone label:
1. Use the joystick to position the cursor beside EDIT ZONE LABEL.
2. Press Iris Open. The following information appears on the monitor:
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
LABEL FOR ZONE
ZONE NUMBER ------
1234567890
ABCDEFGHIJ
KLMNOPQRST
UVWXYZ.,-/
abcdefghij
OK
CANCEL
SPACE
BACKSPACE
klmnopqrst
uvwxyz*;:
BACK
EXIT
3. Use the joystick to position the cursor beside a character. Press Iris Open to enter selection.
To clear a character, position the cursor beside BACKSPACE, and then press Iris Open.
ZONES
ZONE NUMBER
* * * ZONE NOT DEFINED * * *
4. When the label is completed, move the cursor to OK. Press Iris Open to return to the Zones
menu.
<EDIT ZONE LABEL>
<EDIT ZONE>
ZONE ENABLED
ZONE BLANKING
To disable a zone (a zone is enabled automatically when it is programmed) or to blank a zone:
1. Move the cursor beside ZONE ENABLED or ZONE BLANKING.
2. Press Iris Open. The cursor moves to the right.
<CLEAR ZONE>
BACK
EXIT
3. Move the joystick up or down to view selections. Press Iris Open to enter selection.
To clear a zone:
1. Use the joystick to position the cursor beside CLEAR ZONE.
2. Press Iris Open. Follow the instructions on the screen.
*This setting applies only to Pressurized Spectra IV dome systems.
64
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
WINDOW BLANKING
Window blanking allows a user to program four-sided areas that cannot be viewed by the
operator of the dome system. A blanked area will move with pan and tilt functions and
automatically adjust in size as the lens zooms telephoto and wide.
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
The 16X and 18X models have one user-defined window blank available. The 22X, 23X, and 35X
models have eight available user-defined window blanks.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
Spectra IV and Spectra IV SE dome systems have two styles of window blanking: Gray and Smear.
If the style is set to Gray, the blanked area is covered with a solid gray window. If Smear is
selected images behind the window will be noticeable but not distinguishable.
EXIT
To set a window blanking area:
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
1. Use the joystick to position the cursor beside WINDOW BLANKING. Press Iris Open.
The WINDOW BLANKING menu appears on the screen.
2. Move the joystick to position the cursor beside SET WINDOWS. Press Iris Open to enter.
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
BACK
EXIT
3. Position the cursor beside WINDOW NUMBER. Press Iris Open. The cursor moves to the
right.
4. Move the joystick up or down to view selections. Press Iris Open to enter selection.
5. Use the joystick to position the cursor beside EDIT WINDOW LOCATION. Press Iris Open,
and then follow the instructions that appear on the screen. When all four corners are set,
the SET WINDOWS menu reappears, the blanked area is displayed, and the ENABLE
WINDOW option is set to YES.
WINDOW BLANKING
STYLE
Notes:
• Use the inside corner of the window selection tool as a guide
when selecting the upper left, upper right, bottom right, and
bottom left corners of the window.
BLANK ALL ABOVE
BLANK ALL BELOW
<SET WINDOWS>
INSIDE CORNER
• Set windows are not visible when editing a new window
location.
BACK
EXIT
SET WINDOWS
WINDOW NUMBER
<EDIT WINDOW LOCATION>
<EDIT WINDOW ZOOM>
<EDIT SCHEDULE>
ENABLE WINDOW
REVERSE
CLEAR WINDOW
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
C3412M-D (12/08)
65
Download from Www.Somanuals.com. All Manuals Search And Download.
6. The blanked area can be programmed to turn on or off at a specified zoom point. To set the
zoom point:
SPECTRA IV
LANGUAGE
a. Use the joystick to position the cursor beside EDIT WINDOW ZOOM, and then press
Iris Open.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
b. Zoom in to the point where you want window blanking to turn on. Press Iris Open to
set the zoom point.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
Notes:
EXIT
• Since the area is already blanked out, it may be difficult to determine when you want
window blanking to turn on. Reverse the window before setting the zoom point. When
finished reverse the window again to blank out the area.
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
• Increase the size of the window if any part of the blanked area is revealed during PTZ
operations.
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
BACK
EXIT
WINDOW BLANKING
STYLE
Window Blanking Disabled
Window Blanking Enabled
BLANK ALL ABOVE
BLANK ALL BELOW
EDIT SCHEDULE
<SET WINDOWS>
following exceptions. In the Edit Schedule menu, the event type cannot be changed. Also, the
Holiday feature cannot be accessed from the Edit Schedule menu.
BACK
EXIT
SET WINDOWS
REVERSE
WINDOW NUMBER
A blanked out area can be reversed to make it visible and the areas on both sides of it not visible.
The areas above and below the blanking area remain visible. Reversing the window a second
time will return it to its original condition.
<EDIT WINDOW LOCATION>
<EDIT WINDOW ZOOM>
<EDIT SCHEDULE>
ENABLE WINDOW
REVERSE
CLEAR WINDOW
CLEAR WINDOW
All areas that have been set for window blanking are cleared.
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
66
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
BLANK ALL ABOVE/BLANK ALL BELOW
The Blank All Above and Blank All Below options add additional flexibility to setting up privacy areas. These settings are
ideal for applications where a complete pan location needs to be blanked.
Table C. Window Blank Settings
Blank All Above
Tilt Angle Blanked Area
Blank All Below
Tilt Angle Blanked Area
OFF
0
No blanking
OFF
0
No blanking
Horizon to 3° above horizon
Horizon to 92° below horizon
10° to 92° below horizon
20° to 92° below horizon
30° to 92° below horizon
40° to 92° below horizon
50° to 92° below horizon
60° to 92° below horizon
70° to 92° below horizon
80° to 92° below horizon
-10
-20
-30
-40
-50
-60
-70
-80
3° above horizon to 10° below horizon
3° above horizon to 20° below horizon
3° above horizon to 30° below horizon
3° above horizon to 40° below horizon
3° above horizon to 50° below horizon
3° above horizon to 60° below horizon
3° above horizon to 70° below horizon
3° above horizon to 80° below horizon
-10
-20
-30
-40
-50
-60
-70
-80
HORIZON
CAMERA
Figure 3. Window Blank Tilt Angles
C3412M-D (12/08)
67
Download from Www.Somanuals.com. All Manuals Search And Download.
ALARMS
SPECTRA IV
LANGUAGE
The Spectra IV SE dome systems have seven alarm inputs that can be programmed as high,
medium, or low priority. When an alarm is received, an input signal to the dome triggers the user-
defined action (go to preset, run pattern, etc.) programmed for the alarm.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
Note: Refer to the notation in step 6 for the limited alarm features available for 16X and 18X
models.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
There are three global alarm settings:
EXIT
RESUME: This mode lets the dome resume its previous activity (scan, pattern, or previous
position) after all alarms are cleared.
DOME SETTINGS
SEQUENCE: This is the time the dome will perform an alarm activity when more than one alarm
of the same priority occurs at the same time.
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
RESET DELAY: This is the amount of time the dome considers the alarm to be active after it has
physically cleared.
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
BACK
EXIT
Use the following steps to program alarm settings.
1. Use the joystick to position the cursor beside ALARM SETTINGS. Press Iris Open.
2. Select the alarm number:
a. Use the joystick to position the cursor beside ALARM NUMBER.
b. Press Iris Open. The cursor moves to the right.
c. Move the joystick up or down to view selections. Press Iris Open to enter selection.
ALARMS
RESUME
SEQUENCE (SECS)
RESET DELAY (SECS)
<ALARM SETTINGS>
BACK
EXIT
ALARM SETTINGS
ALARM NUMBER
ALARM PRIORITY
ALARM ACTION
ACTIVATE AUX
ALARM CONTACT
<EDIT SCHEDULE>
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
68
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Select the alarm priority:
SPECTRA IV
LANGUAGE
a. Use the joystick to position the cursor beside ALARM PRIORITY.
b. Press Iris Open. The cursor moves to the right.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
c. Move the joystick up or down to view the available selections. Available settings
include HIGH, MEDIUM, and LOW (default). If multiple alarms with different priorities
are active at the same time, the dome will only go to the alarms with the highest
priority.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
EXIT
d. Press Iris Open to enter selection.
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
HIGH: Alarm action takes highest priority and will override manual PTZ control.
MEDIUM/LOW: Alarm action will not occur if an alarm occurs during manual pan,
tilt, and zoom control.
4. Set the alarm action:
a. Use the joystick to position the cursor beside ALARM ACTION.
b. Press Iris Open. The cursor moves to the right.
c. Move the joystick up or down to view the available selections. The following are the
settings for alarm action:
BACK
EXIT
NONE: No action when alarm is triggered.
PRESET: Dome goes to the preset that is the same as the alarm number. Preset 1 will
go to Alarm 1.
ALARMS
RESUME
SEQUENCE (SECS)
RESET DELAY (SECS)
PATTERN 1: Dome runs pattern 1 when alarm is triggered.
PATTERN 2: Dome runs pattern 2 when alarm is triggered.
PATTERN 3: Dome runs pattern 3 when alarm is triggered.
PATTERN 4: Dome runs pattern 4 when alarm is triggered.
PATTERN 5: Dome runs pattern 5 when alarm is triggered.
PATTERN 6: Dome runs pattern 6 when alarm is triggered.
PATTERN 7: Dome runs pattern 7 when alarm is triggered.
PATTERN 8: Dome runs pattern 8 when alarm is triggered.
AUTO SCAN: Dome starts auto scan operation when alarm is triggered.
RANDOM SCAN: Dome starts random scan operation when alarm is triggered.
FRAME SCAN: Dome starts frame scan operation when alarm is triggered.
<ALARM SETTINGS>
BACK
EXIT
ALARM SETTINGS
ALARM NUMBER
ALARM PRIORITY
ALARM ACTION
ACTIVATE AUX
ALARM CONTACT
<EDIT SCHEDULE>
d. Press Iris Open to enter selection.
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
C3412M-D (12/08)
69
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Set the auxiliary to activate:
SPECTRA IV
LANGUAGE
a. Use the joystick to position the cursor beside ACTIVATE AUX.
b. Press Iris Open. The cursor moves to the right.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
c. Move the joystick up or down to view the following available selections.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
NO (default): Not activated.
EXIT
1: An alarm action will close AUX 1.
2: An alarm action will close AUX 2.
DOME SETTINGS
d. Press Iris Open to enter selection.
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
Note: The AUX 1/AUX2 will stop when all the alarms assigned to it have cleared. If the
AUX1/AUX is set up as momentary, then it will be activated each time a new alarm is
activated.
<WINDOW BLANKING>
<ALARMS>
<AUX>
6. Set the alarm contact:
<TITLE TEXT>
<ALERT>*
a. Use the joystick to position the cursor beside ALARM CONTACT.
b. Press Iris Open. The cursor moves to the right.
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
BACK
EXIT
c. Move the joystick up or down to view the following available selections.
N/O (default): Normally open.
N/C: Normally closed.
ALARMS
RESUME
SEQUENCE (SECS)
RESET DELAY (SECS)
d. Press Iris Open to enter selection.
Note: The alarm contact feature is functional and available for 16X and 18X models only if
the dome drive is installed in a Spectra III SE or Spectra IV SE back box.
<ALARM SETTINGS>
BACK
EXIT
7. To edit the alarm schedule:
with the following exceptions. In the Edit Schedule menu, the event type cannot be
changed. Also, the Holiday feature cannot be accessed from the Edit Schedule menu.
ALARM SETTINGS
ALARM NUMBER
ALARM PRIORITY
ALARM ACTION
ACTIVATE AUX
ALARM CONTACT
<EDIT SCHEDULE>
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
70
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
AUX
Note: If a 16X or 18X model dome drive is installed in a Spectra III SE or Spectra IV SE back box,
the auxiliary feature is functional and available. If a 16X or 18X model is installed in a standard
Spectra III or Spectra IV back box, the auxiliary feature is not available.
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
An auxiliary output is a programmable signal from the dome back box that can trigger another
device to operate. An auxiliary output is programmable to trigger from an alarm or from a controller.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
An AUX 1 command from the controller will activate the relay in the dome and operate the device
that is connected to the relay. The output of AUX 1 can be connected to the alarm input of a
system switch to activate automatic monitor switching and recording.
EXIT
An AUX 2 command from the controller will place a ground at the output of AUX 2 to operate the
device that is connected to it.
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
The following are the available AUX mode settings:
TOGGLE (default): Changes the state of the auxiliary output every time an AUX command
is received from the controller.
LATCHING: Must receive an AUX ON/AUX OFF command from the controller to turn the
auxiliary output on/off.
MOMENTARY: An AUX ON command from the controller turns the auxiliary output on for the
programmed DWELL TIME. The auxiliary output will automatically turn off when the dwell time
is finished.
EDIT SCHEDULE
BACK
EXIT
the following exceptions. In the Edit Schedule menu, the event type cannot be changed. Also,
the Holiday feature cannot be accessed from the Edit Schedule menu.
AUX
AUX 1 MODE
TOGGLE
DWELL TIME (SECS)
AUX 2 MODE
DWELL TIME (SECS)
<EDIT SCHEDULE>
1
TOGGLE
1
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
C3412M-D (12/08)
71
Download from Www.Somanuals.com. All Manuals Search And Download.
TITLE TEXT
Title text is the label used to identify the camera viewed on the monitor. Up to 20 characters can
be used for a title.
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
To edit the title text label, do the following:
1. Use the joystick to position the cursor beside EDIT TITLE TEXT.
2. Press Iris Open. The following appears on the monitor:
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
EXIT
EDIT TITLE TEXT
1234567890
ABCDEFGHIJ
KLMNOPQRST
UVWXY.,-/
OK
CANCEL
SPACE
BACKSPACE
abcdefghij
DOME SETTINGS
klmnopqrst
uvwxyz#&:*
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
3. Use the joystick to position the cursor beside a character. Press Iris Open to select the
character. To clear a character, position the cursor beside BACKSPACE, and then press Iris
Open.
4. When the title is completed, move the cursor to OK. Press Iris Open to return to the Title
Text menu.
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
5. Enable the title text label by doing the following:
a. Move the cursor beside ENABLE TITLE TEXT.
b. Press Iris Open. The cursor moves to the right.
<EVENT>
BACK
EXIT
c. Move the joystick up or down to view the selections. Select ON and then press Iris
Open to enable the title text.
TITLE TEXT
ENABLE TITLE TEXT
<EDIT TITLE TEXT>
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
72
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
ALERT
Note: The Alert option applies only to Pressurized Spectra IV dome systems. Spectra IV systems
SPECTRA IV
that are not pressurized will not display this menu item.
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT
Sensors strategically placed inside the pressurized dome system continually monitor pressure,
temperature, and dew point. If internal conditions reach unacceptable levels, an alert message
appears on the screen describing the alert condition. For example, if pressure drops below 1 psig,
LOW PRESSURE is displayed on the monitor.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
The following system conditions will trigger an alert message:
EXIT
System Condition
Alert Message
Temperature is above 140°F (60°C)
Temperature is below -40°F (-40°C)
Pressure is above 13 PSIG
Pressure is below 1 PSIG
HIGH TEMPERATURE
LOW TEMPERATURE
HIGH PRESSURE
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
LOW PRESSURE
The difference between the temperature and
the dew point is less than or equal to 3°C.
DEW POINT (HIGH HUMIDITY)
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
The alert message will be repeatedly displayed until the system controller acknowledges the
alert condition by selecting ACK ALERT in the main menu. Once acknowledged, the alert message
changes to the programmed acknowledge action (ACK ACTION). If the alert condition remains
active after a period of time, the alert message reappears on the monitor, restarting the alert
message cycle. This cycle will continue to repeat until the alert condition is resolved.
BACK
EXIT
REPEAT
This setting programs how often an alert message is repeatedly displayed until the system
controller acknowledges the alert condition. The following are the settings:
CONSTANT: The alert message is continuously displayed on the monitor until acknowledged.
ALERT
REPEAT
15 MIN: The alert message is displayed every 15 minutes for a 15-second duration until
acknowledged.
ACK ACTION
ACTIVATE AUX
<CURRENT READING>
RESET ALERT
30 MIN: The alert message is displayed every 30 minutes for a 15-second duration until
acknowledged.
BACK
EXIT
60 MIN: The alert message is displayed every 60 minutes for a 15-second duration until
acknowledged.
OFF: The alert message is disabled and will not be displayed on the monitor.
C3412M-D (12/08)
73
Download from Www.Somanuals.com. All Manuals Search And Download.
ACK ACTION
SPECTRA IV
LANGUAGE
Set ACK ACTION to program the frequency at which an alert message is displayed after the alert
condition has been acknowledged. The following settings are available:
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT
ALWAYS ON: The alert message is displayed until alert conditions are cleared.
OFF 8 HRS: The alert message is turned off for 8 hours. Message returns after 8 hours if the
alert condition persists.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
OFF 24 HRS: The alert message is turned off for 24 hours. Message returns after 24 hours if
EXIT
the alert condition persists.
OFF 48 HRS: The alert message is turned off for 48 hours. Message returns after 48 hours if the
alert condition persists.
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
ACTIVATE AUX
This setting activates an auxiliary when an alert condition exists. Settings include the following
options:
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>
<CLEAR>
NONE (default): Not activated.
1: An alert condition will close AUX 1.
2: An alert condition will close AUX 2.
<PASSWORD>
<CLOCK>
CURRENT READING
The Current Reading menu displays the existing status of temperature, pressure, and dew point
inside the dome system. An arrow displayed to the left of a menu item denotes that an alert
condition exists.
<EVENT>
BACK
EXIT
ALERT
An up arrow indicates the reading is over the threshold. A down arrow indicates the reading is
below the threshold.
REPEAT
ACK ACTION
ACTIVATE AUX
<CURRENT READING>
RESET ALERT
The high temperature alert occurs if the temperature is above 140°F (60°C).
The low temperature alert occurs if the temperature is below -40°F (-40°C).
The high pressure alert occurs if the pressure is above 13 PSIG.
The low pressure alert occurs if the pressure is below 1 PSIG.
BACK
EXIT
The dew point (high humidity) alert occurs if the difference between the temperature and the dew
point is less than or equal to 3°C.
Note: The normal operating temperature inside the unit will be greater than the temperature
outside the back box due to the heat emitted by the system’s electronics.
CURRENT READING
TEMPERATURE
DEWPOINT
PRESSURE
REFRESH
RESET ALERT
Reset alert clears the alert condition and removes the alert label from the monitor. The system
automatically checks internal conditions 60 seconds after reset. If conditions are still unacceptable,
the alert label reappears on the screen indicating further corrective action is required.
BACK
EXIT
74
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEAR
Use this setting to clear user-defined settings or return the dome to factory default settings.
The following are the available settings:
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
ALL WINDOW BLANKING: Clears all blanked windows. To clear a single blanked window,
EXIT
RESTORE FACTORY DEFAULTS: Restores all camera settings to factory default settings.
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
BACK
EXIT
CLEAR
CLEAR ALL ZONES
CLEAR ALL PRESETS
CLEAR ALL PATTERNS
CLEAR ALL WINDOW BLANKING
CLEAR ALL EVENTS
RESTORE FACTORY DEFAULTS
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
C3412M-D (12/08)
75
Download from Www.Somanuals.com. All Manuals Search And Download.
PASSWORD
Spectra IV and Spectra IV SE feature password protection to prevent unauthorized changes to the
dome settings. An operator can open the System Information and Display Setup menus, but
cannot access any of the dome settings menus.
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
Controller/keyboard commands cannot override password-protected settings. If a keyboard is
used to set a preset, pattern, or zone, the Enter Password menu appears on the monitor.
The password must be entered before programming can continue.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
At least one character must be entered to create a valid password.
EXIT
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
BACK
EXIT
PASSWORD
ENABLE PASSWORD
<EDIT PASSWORD>
BACK
EXIT
EDIT THE PASSWORD
----------
1234567890
OK
ABCDEFGHIJ
KLMNOPQRST
UVWXYZ.,-/
CANCEL
SPACE
BACKSPACE
abcdefghij
klmnopqrst
uvwxyz*;:
*This setting applies only to Pressurized Spectra IV dome systems.
76
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
CLOCK
The clock is used to program the current date and time. The date and time set in the Clock menu
is used to program events. The date and time can also be displayed on the monitor when the
menus are not being accessed.
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
To program the clock, do the following:
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
1. Use the joystick to position the cursor beside TIME BASE. Press Iris Open. The following are
the settings for time base:
EXIT
POWER LINE: This is the most accurate time base and is the preferred selection in areas
with a stable power line frequency.
INTERNAL CLOCK: The internal clock should be used in areas where the power line
frequency is not accurate.
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
a. Move the joystick up or down to view the selections.
b. Press Iris Open to select INTERNAL CLOCK or POWER LINE.
2. Use the joystick to position the cursor beside TIME FORMAT. Press Iris Open. Move the
joystick up or down to view the selections. Select 12 HOUR or 24 HOUR, and then press Iris
Open to confirm the time format.
3. Use the joystick to position the cursor beside SET TIME. Press Iris Open. Scroll through the
hours until the desired time appears. Use the joystick to move the cursor to the right. Scroll
through the minutes until the desired time appears. Press Iris Open to select the time.
BACK
EXIT
4. Use the joystick to position the cursor beside DATE FORMAT. Press Iris Open. Move the
joystick up or down to select MM/DD/YYYY or DD/MM/YYYY. Press Iris Open to confirm
the date format.
CLOCK
5. Use the joystick to position the cursor beside SET DATE. Press Iris Open. Scroll through the
TIME BASE
TIME FORMAT
SET TIME
days, months, and years until the desired number appears. Press Iris Open to select the
date.
DATE FORMAT
SET DATE
6. Use the joystick to position the cursor beside DAYLIGHT SAVINGS. Press Iris Open.
The following are the settings for daylight savings:
DAYLIGHT SAVINGS
BACK
EXIT
OFF: Daylight saving time will be turned off.
FIXED DATE: Daylight saving time occurs on the same date each year.
RELATIVE DATE: Daylight saving time occurs on a different date each year, such as the
first Sunday in April.
*This setting applies only to Pressurized Spectra IV dome systems.
C3412M-D (12/08)
77
Download from Www.Somanuals.com. All Manuals Search And Download.
7. If FIXED DATE was selected, the following appears on the monitor:
CLOCK
TIME BASE
TIME FORMAT
SET TIME
INTERNAL CLOCK
12 HOUR
00:00 AM
DATE FORMAT
SET DATE
MM/DD/YYYY
00/00/0000
DAYLIGHT SAVINGS
TIME SHIFT
START DATE
MONTH
FIXED DATE
1 HOUR
APRIL
1
02:00 AM
DAY
START TIME
END DATE
MONTH
DAY
OCTOBER
1
02:00 AM
END TIME
BACK
EXIT
a. Use the joystick to position the cursor beside TIME SHIFT. Press Iris Open. Scroll through the options until the
desired selection appears. Press Iris Open to select the time shift.
b. Use the joystick to position the cursor beside the start date MONTH. Press Iris Open. Scroll through the options
until the desired month appears. Press Iris Open to select the month.
c. Use the joystick to position the cursor beside the start date DAY. Press Iris Open. Scroll through the options until
the desired date appears. Press Iris Open to select the day.
d. Use the joystick to position the cursor beside START TIME. Press Iris Open. Scroll through the hours until the
desired time appears. Use the joystick to move the cursor to the right. Scroll through the minutes until the
desired time appears. Press Iris Open to select the start time.
e. Repeat steps b–d for the ending date and time.
78
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
8. If RELATIVE DATE was selected, the following appears on the monitor:
CLOCK
TIME BASE
TIME FORMAT
SET TIME
INTERNAL CLOCK
12 HOUR
00:00 AM
DATE FORMAT
SET DATE
MM/DD/YYYY
00/00/0000
DAYLIGHT SAVINGS RELATIVE DATE
TIME SHIFT
START DATE
MONTH
1 HOUR
APRIL
1ST
SUNDAY
02:00 AM
WEEK
DAY
START TIME
END DATE
MONTH
WEEK
OCTOBER
LAST
SUNDAY
02:00 AM
DAY
END TIME
BACK
EXIT
Follow the instructions in step 7 for FIXED DATE, adding WEEK.
C3412M-D (12/08)
79
Download from Www.Somanuals.com. All Manuals Search And Download.
EVENT
An event is a preprogrammed camera, park, scan, preset, pattern, window blanking, alarm, or
auxiliary function that can be performed automatically at a specific date and time.
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
For example, suppose a camera is set to run in a continuous pattern that scans a parking lot
during business hours Monday through Friday. On Saturday and Sunday the camera needs to stop
running the pattern and observe a gate. First, program a preset to set the camera to observe the
gate. Second, schedule an event to activate the preset on the weekends. Finally, a second,
separate event must be scheduled to end the first event and allow the camera to return to the
pattern on Monday.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
EXIT
Note: Events do not have a selectable duration. A second event must be scheduled to end a
previous event.
DOME SETTINGS
Events can be programmed from the Preset, Pattern, Window Blanking, Alarm, or Aux menus, or
they can be programmed from the Event menu. Events are managed individually or as a group
from the Event menu.
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
80
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
EVENT TYPE
SPECTRA IV
LANGUAGE
Any of the available event types can be selected from this menu, or you may select ALL EVENTS
to manage the events as a group.The following are the settings for event type:
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
SCAN: A scan event executes a specified scan (random, auto, or frame scan) using the limit
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
PARK: A park event executes the user-defined park action as specified in the Motion menu.
EXIT
WINDOW BLANKING: A window blanking event activates or deactivates a previously defined
window blank. The window blank remains activated or deactivated until another programmed
event changes the state of the window or you modify it through the Window Blanking menu.
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
ALARM: An alarm event executes the action associated with the specified alarm number. Refer
PATTERN: A pattern event starts a previously defined pattern when the event is triggered. Refer
<TITLE TEXT>
<ALERT>*
CAMERA: A camera event assigns the camera settings of a preset to the current camera
by the event must be defined prior to setting up a camera event.
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
BACK
EXIT
For the camera event to function, the referenced preset must have Custom Camera Settings
Note: If you have camera settings defined in the Camera menu that you wish to restore
following a camera event which overwrites those settings, you must save the original settings as
a separate preset prior to the camera event being triggered. You can then set a second camera
event to call the preset that has the original settings saved. Camera settings can also be changed
manually from the Camera menu following the original camera event.
EVENT
EVENT TYPE
EVENT LABEL
<EDIT EVENT LABEL>
<EDIT EVENT>
<CLEAR EVENT>
<LIST EVENT>
PRESET: A preset event executes a previously defined preset when the event is triggered. Refer
HOLIDAY
Note: The event type cannot be changed if you are accessing it through the Edit Schedule option
from the Preset, Pattern, Window Blanking, Alarm, or Aux menu.
<EDIT HOLIDAY>
<CLEAR HOLIDAY>
<LIST HOLIDAYS>
BACK
EXIT
REFERENCE INFORMATION
*This setting applies only to Pressurized Spectra IV dome systems.
C3412M-D (12/08)
81
Download from Www.Somanuals.com. All Manuals Search And Download.
EVENT LABEL
Set the event label to NEW to create a new event.
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
Use the following steps to manage an existing event.
1. Use the joystick to position the cursor beside EVENT LABEL. Press Iris Open.
2. Move the joystick up or down to scroll through the events. Press Iris Open to enter selection.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
EXIT
As you scroll through the events, the reference information at the bottom of the screen
displays the corresponding details for each event. To view a list of all events and their
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
EVENT LABEL
After an event is programmed, the label can be changed using the following steps:
1. Use the joystick to position the cursor beside EDIT EVENT LABEL.
2. Press Iris Open. The following appears on the monitor:
EDIT EVENT LABEL
EVENT 1
1234567890
ABCDEFGHIJ
KLMNOPQRST
UVWXY.,-/
abcdefghij
OK
CANCEL
BACK
EXIT
SPACE
BACKSPACE
klmnopqrst
uvwxyz#&:*
EVENT
3. Use the joystick to position the cursor beside a character. Press Iris Open to enter the
selection. To clear a character, position the cursor beside BACKSPACE, and then press Iris
Open.
EVENT TYPE
EVENT LABEL
<EDIT EVENT LABEL>
<EDIT EVENT>
<CLEAR EVENT>
<LIST EVENT>
4. When the label is completed, move the cursor to OK. Press Iris Open to return to the Edit
Schedule menu.
HOLIDAY
After an event is labeled, the label will be displayed when the event is activated according to the
change the way a label is displayed on the monitor.
<EDIT HOLIDAY>
<CLEAR HOLIDAY>
<LIST HOLIDAYS>
BACK
EXIT
REFERENCE INFORMATION
*This setting applies only to Pressurized Spectra IV dome systems.
82
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
EDIT EVENT
Use the following steps to edit an event.
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
1. Use the joystick to position the cursor beside EDIT EVENT.
2. Press Iris Open. The following appears on the monitor:
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
EDIT EVENT
EXIT
EVENT LABEL
EVENT 1
EVENT ACTIVE
EVENT TIME
EVENT OCCURS
SUNDAY
NO
12:00 AM
OFF
DOME SETTINGS
MONDAY
OFF
TUESDAY
OFF
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
WEDNESDAY
THURSDAY
FRIDAY
OFF
OFF
OFF
SATURDAY
HOLIDAY
OFF
SKIP HOLIDAYS
EVENT TYPE
NUMBER
PRESET
1
BACK
EXIT
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
a. Use the joystick to position the cursor beside EVENT ACTIVE. Press Iris Open. Scroll
to select NO to leave the event inactive or YES to activate the event. Press Iris Open to
confirm your selection.
<EVENT>
BACK
EXIT
b. Use the joystick to position the cursor beside EVENT TIME. Press Iris Open. Scroll
through the hours until the desired time appears. Use the joystick to move the cursor
to the right. Scroll through the minutes until the desired time appears. Press Iris Open
to select the time.
EVENT
EVENT TYPE
EVENT LABEL
c. Use the joystick to position the cursor beside SUNDAY. Press Iris Open. The available
options are OFF and ON. Press Iris Open to confirm your selection.
<EDIT EVENT LABEL>
<EDIT EVENT>
<CLEAR EVENT>
<LIST EVENT>
d. Follow the instructions in the previous step for the remaining days of the week.
HOLIDAY
<EDIT HOLIDAY>
<CLEAR HOLIDAY>
<LIST HOLIDAYS>
e. Use the joystick to position the cursor beside HOLIDAY. Press Iris Open. The following
are the holiday settings:
BACK
EXIT
SKIP HOLIDAYS: The event will not occur on a day of the week for which it is set if
that date is in the list of holidays.
REFERENCE INFORMATION
ON: The event will activate on holidays that are set in the Event menu, in addition to
its normally scheduled days of the week.
OFF: The event only occurs on the days of the week that it is scheduled; holidays have
no effect on the event.
*This setting applies only to Pressurized Spectra IV dome systems.
C3412M-D (12/08)
83
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEAR EVENT
To clear an event:
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
1. Use the joystick to position the cursor beside CLEAR EVENT.
2. Press Iris Open.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
3. Follow the directions displayed on the monitor.
EXIT
LIST EVENT
To list events:
DOME SETTINGS
1. Use the joystick to position the cursor beside LIST EVENT.
2. Press Iris Open.
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
3. All programmed events will be listed.
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
HOLIDAY
Use the following steps to create a new holiday.
<PASSWORD>
<CLOCK>
<EVENT>
1. Use the joystick to position the cursor beside HOLIDAY. Press Iris Open.
BACK
EXIT
2. Move the joystick up or down to scroll through the options. If no holidays were created in
the past, NEW is the only selectable option. Press Iris Open to select NEW.
EVENT
Use the following steps to manage an existing holiday.
1. Use the joystick to position the cursor beside HOLIDAY. Press Iris Open.
EVENT TYPE
EVENT LABEL
<EDIT EVENT LABEL>
<EDIT EVENT>
<CLEAR EVENT>
<LIST EVENT>
2. Move the joystick up or down to scroll through the holidays. Press Iris Open to enter a
selection.
HOLIDAY
<EDIT HOLIDAY>
<CLEAR HOLIDAY>
<LIST HOLIDAYS>
Note: Holidays cannot be changed through the Edit Schedule option from the Preset, Pattern,
Window Blanking, Alarm, or Aux menus.
BACK
EXIT
REFERENCE INFORMATION
*This setting applies only to Pressurized Spectra IV dome systems.
84
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
EDIT HOLIDAY
Use the following steps to edit a holiday:
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
1. Use the joystick to position the cursor beside EDIT EVENT LABEL.
2. Press Iris Open.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
3. Use the joystick to position the cursor beside OCCURRENCE. Press Iris Open. The following
are the settings for Occurrence:
EXIT
FIXED DATE: The holiday occurs on the same date each year.
RELATIVE DATE: The holiday occurs on a different date each year, such as the third
Sunday in April.
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
4. If FIXED DATE was selected as the occurrence, the following appears on the monitor:
EDIT HOLIDAY
OCCURRENCE
MONTH
DAY
FIXED DATE
JANUARY
1
BACK
EXIT
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
a. Use the joystick to position the cursor beside MONTH. Press Iris Open. Scroll through
the options until the desired month appears. Press Iris Open to select the month.
<EVENT>
BACK
EXIT
b. Use the joystick to position the cursor beside DAY. Press Iris Open. Scroll through the
options until the desired date appears. Press Iris Open to select the day.
5. If RELATIVE DATE was selected as the occurrence, the following appears on the monitor:
EVENT
EVENT TYPE
a. Use the joystick to position the cursor beside MONTH. Press Iris Open. Scroll through
the options until the desired month appears. Press Iris Open to select the month.
EVENT LABEL
<EDIT EVENT LABEL>
<EDIT EVENT>
<CLEAR EVENT>
<LIST EVENT>
b. Use the joystick to position the cursor beside WEEK. Press Iris Open. Scroll through
the options until the desired week appears. Press Iris Open to select the week.
HOLIDAY
<EDIT HOLIDAY>
<CLEAR HOLIDAY>
<LIST HOLIDAYS>
c. Use the joystick to position the cursor beside DAY. Press Iris Open. Scroll through the
options until the desired day of the week appears. Press Iris Open to select the day.
BACK
EXIT
REFERENCE INFORMATION
*This setting applies only to Pressurized Spectra IV dome systems.
C3412M-D (12/08)
85
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEAR HOLIDAY
To clear a holiday:
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
1. Use the joystick to position the cursor beside CLEAR HOLIDAY.
2. Press Iris Open.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
3. Follow the directions displayed on the monitor.
EXIT
LIST HOLIDAYS
To list events:
DOME SETTINGS
1. Use the joystick to position the cursor beside LIST HOLIDAYS.
2. Press Iris Open.
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
3. All programmed holidays will be listed.
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
BACK
EXIT
EVENT
EVENT TYPE
EVENT LABEL
<EDIT EVENT LABEL>
<EDIT EVENT>
<CLEAR EVENT>
<LIST EVENT>
HOLIDAY
<EDIT HOLIDAY>
<CLEAR HOLIDAY>
<LIST HOLIDAYS>
BACK
EXIT
REFERENCE INFORMATION
*This setting applies only to Pressurized Spectra IV dome systems.
86
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
SCHEDULED EVENTS
Use this page to record scheduled events.
EVENT NUMBER
Example:
EVENT TYPE
LABEL
TIME
OCCURS
HOLIDAY
1
Preset
Weekend
11:00 AM
Sat–Sun
Skips Holidays
Description: Camera focuses on gate on weekends when the office is closed.
_______________________________________________________________________________________
_______________________________________________________________________________________
_______________________________________________________________________________________
_______________________________________________________________________________________
_______________________________________________________________________________________
_______________________________________________________________________________________
_______________________________________________________________________________________
_______________________________________________________________________________________
_______________________________________________________________________________________
_______________________________________________________________________________________
_______________________________________________________________________________________
_______________________________________________________________________________________
_______________________________________________________________________________________
_______________________________________________________________________________________
_______________________________________________________________________________________
_______________________________________________________________________________________
_______________________________________________________________________________________
_______________________________________________________________________________________
_______________________________________________________________________________________
_______________________________________________________________________________________
C3412M-D (12/08)
87
Download from Www.Somanuals.com. All Manuals Search And Download.
Reset, Cycle Power, Reboot
RESET CAMERA
Use this function to reset all camera settings to factory default parameters.
SPECTRA IV
LANGUAGE
ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
CYCLE CAMERA POWER
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
If the camera is not operating or if you lose camera control, cycle camera power. Cycling camera
power resets the camera but does not change any saved camera settings.
EXIT
REBOOT SYSTEM
Reboot the system if it is not operating or if there is no control. Rebooting the system will cycle
dome and camera power without changing programmed dome settings.
88
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
Software/Language File Upload
The RJ-45 data port of the dome drive allows access for on-site setup, testing, and uploading of revised operating
software and language files. A Pelco field service tool is required to perform these operations. Field service tools include
Pelco’s remote monitor kit (IPS-RMK), remote data port box (IPS-RDPE-2), and remote monitor cable (IPS-CABLE).
For instructions on how to upload revised operating software and language files refer to the Installation/Operation manual
supplied with the field service tool.
Note: Only perform software uploads when necessary. Software uploads do not need to be performed if the dome system
is operating properly.
During a software/language file upload, a progress bar will appear on the monitor to indicate data is being transferred to
the Spectra dome system. The default setting for data transmission is 115.2 KB per second. Noisy and long-run
connections will slow the transmission rate.
C3412M-D (12/08)
89
Download from Www.Somanuals.com. All Manuals Search And Download.
Suggested Preventative Maintenance
The Spectra IV and Spectra IV SE dome systems do not require any special maintenance.
Occasionally, dust may build up on the inside or the outside of the dome. If this occurs, turn power off to the unit and
remove the lower dome from the back box. Remove the dust from the lower dome using compressed air from a spray can.
Replace the lower dome following the installation instructions that were shipped with it.
Warning: Proper eye protection should be worn when using compressed air cans.
90
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
16X MODELS
DD4TC16
Signal Format
NTSC
Scanning System
Image Sensor
Effective Pixels
Horizontal Resolution
Lens
Zoom Speed (optical range)
Horizontal Angle of View
Focus
Maximum Sensitivity at 35 IRE
Sync System
2:1 Interlace
1/4-inch interline transfer CCD
768 (H) X 494 (V)
>470 TV lines
f/1.4 (focal length, 4~64 mm; 16X optical zoom, 8X digital zoom)
1.9/3.6/6.0 seconds
43° at 4 mm wide zoom; 3° at 64 mm telephoto zoom
Automatic with manual override
0.05 lux at 1/2 sec. shutter speed (color)
AC line lock, phase adjustable using remote control, V-Sync
Automatic (electronic iris)/manual; 1/2 ~ 1/30,000
Automatic iris control with manual override
Automatic with manual override
1 Vp-p, 75 ohms
Shutter Speed
Iris Control
Gain Control
Video Output
Video Signal-to-Noise
>50 dB
DD4TC16-X
Signal Format
PAL
Scanning System
Image Sensor
Effective Pixels
Horizontal Resolution
Lens
Zoom Speed (optical range)
Horizontal Angle of View
Focus
Maximum Sensitivity at 35 IRE
Sync System
2:1 Interlace
1/4-inch interline transfer CCD
752 (H) X 582 (V)
>460 TV lines
f/1.4 (focal length, 4~64 mm; 16X optical zoom, 8X digital zoom)
1.9/3.6/6.0 seconds
43° at 4 mm wide zoom; 3° at 64 mm telephoto zoom
Automatic with manual override
0.05 lux at 1/1.5 sec. shutter speed (color)
AC line lock, phase adjustable using remote control, V-Sync
Automatic (electronic iris)/manual; 1/1.5~1/30,000
Automatic iris control with manual override
Automatic with manual override
1 Vp-p, 75 ohms
Shutter Speed
Iris Control
Gain Control
Video Output
Video Signal-to-Noise
>50 dB
C3412M-D (12/08)
91
Download from Www.Somanuals.com. All Manuals Search And Download.
18X MODELS
DD4CBW18
Signal Format
NTSC
Scanning System
Image Sensor
Effective Pixels
2:1 Interlace
1/4-inch progressive scan CCD
768 (H) X 494 (V)
Horizontal Resolution
Lens
Zoom Speed (optical range)
Horizontal Angle of View
Focus
540 TV lines
f/1.6 (focal length, 3.8~68.4 mm; 18X optical zoom, 12X digital zoom)
2.9/4.2/5.8 seconds
51° at 3.8 mm wide zoom; 3° at 68.4 mm telephoto zoom
Automatic with manual override
Maximum Sensitivity at 35 IRE
0.025 lux at 1/2 sec. shutter speed (color)
0.1 lux at 1/60 sec. shutter speed (B-W)
0.004 lux at 1/2 sec. shutter speed (B-W)
Sync System
Internal/AC line lock, phase adjustable using remote control, V-Sync
Automatic with manual override
Automatic (electronic iris)/manual; 1/2~1/30,000
Automatic iris control with manual override
Automatic/off
White Balance
Shutter Speed
Iris Control
Gain Control
Video Output
Video Signal-to-Noise
1 Vp-p, 75 ohms
>50 dB
DD4CBW18-X
Signal Format
PAL
Scanning System
Image Sensor
Effective Pixels
2:1 Interlace
1/4-inch progressive scan CCD
752 (H) X 582 (V)
Horizontal Resolution
Lens
Zoom Speed (optical range)
Horizontal Angle of View
Focus
540 TV lines
f/1.6 (focal length, 3.8~68.4 mm; 18X optical zoom, 12X digital zoom)
2.9/4.2/5.8 seconds
51° at 3.8 mm wide zoom; 3° at 68.4 mm telephoto zoom
Automatic with manual override
Maximum Sensitivity at 35 IRE
0.025 lux at 1/1.5 sec. shutter speed (color)
0.1 lux at 1/50 sec. shutter speed (B-W)
0.004 lux at 1/1.5 sec. shutter speed (B-W)
Sync System
Internal/AC line lock, phase adjustable using remote control, V-Sync
Automatic with manual override
Automatic (electronic iris)/manual; 1/1.5~1/30,000
Automatic iris control with manual override
Automatic/off
White Balance
Shutter Speed
Iris Control
Gain Control
Video Output
Video Signal-to-Noise
1 Vp-p, 75 ohms
>50 dB
92
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
22X MODELS
DD4C22
Signal Format
NTSC
Scanning System
Image Sensor
2:1 Interlace
1/4-inch CCD
Effective Pixels
Horizontal Resolution
Lens
Zoom Speed (optical range)
Horizontal Angle of View
Focus
Maximum Sensitivity at 35 IRE
Sync System
White Balance
768 (H) X 494 (V)
>470 TV lines
f/1.6 (focal length, 4~88 mm; 22X optical zoom, 12X digital zoom)
2.4/3.9/6.3 seconds
47° at 4 mm wide zoom; 2.2° at 88 mm telephoto zoom
Automatic with manual override
0.02 lux at 1/2 sec. shutter speed
Internal/AC line lock, phase adjustable using remote control, V-Sync
Automatic with manual override
Automatic (electronic iris)/manual; 1/2~1/30,000
Automatic iris control with manual override
Automatic/off
Shutter Speed
Iris Control
Gain Control
Video Output
1 Vp-p, 75 ohms
Video Signal-to-Noise
>50 dB
DD4C22-X
Signal Format
PAL
Scanning System
Image Sensor
2:1 Interlace
1/4-inch CCD
Effective Pixels
Horizontal Resolution
Lens
Zoom Speed (optical range)
Horizontal Angle of View
Focus
Maximum Sensitivity at 35 IRE
Sync System
White Balance
752 (H) X 582 (V)
>460 TV lines
f/1.6 (focal length, 4~88 mm; 22X optical zoom, 12X digital zoom)
2.4/3.9/6.3 seconds
47° at 4 mm wide zoom; 2.2° at 88 mm telephoto zoom
Automatic with manual override
0.02 lux at 1/1.5 sec. shutter speed
Internal/AC line lock, phase adjustable using remote control, V-Sync
Automatic with manual override
Automatic (electronic iris)/manual; 1/1.5~1/30,000
Automatic iris control with manual override
Automatic/off
Shutter Speed
Iris Control
Gain Control
Video Output
1 Vp-p, 75 ohms
Video Signal-to-Noise
>50 dB
C3412M-D (12/08)
93
Download from Www.Somanuals.com. All Manuals Search And Download.
23X MODELS
DD4CBW23
Signal Format
NTSC
Scanning System
Image Sensor
Effective Pixels
2:1 Interlace
1/4-inch progressive scan CCD
768 (H) X 494 (V)
Horizontal Resolution
Lens
Zoom Speed (optical range)
Horizontal Angle of View
Focus
540 TV lines
f/1.6 (focal length, 3.6~82.8 mm; 23X optical zoom, 12X digital zoom)
2.9/4.2/5.8 seconds
54° at 3.6 mm wide zoom; 2.5° at 82.8 mm telephoto zoom
Automatic with manual override
Maximum Sensitivity at 35 IRE
0.025 lux at 1/2 sec. shutter speed (color)
0.1 lux at 1/60 sec. shutter speed (B-W)
0.004 lux at 1/2 sec. shutter speed (B-W)
Sync System
Internal/AC line lock, phase adjustable using remote control, V-Sync
White Balance
Shutter Speed
Iris Control
Automatic with manual override
Automatic (electronic iris)/manual; 1/2~1/30,000
Automatic iris control with manual override
Gain Control
Video Output
Video Signal-to-Noise
Wide Dynamic Range
Automatic/off
1 Vp-p, 75 ohms
>50 dB
80X
94
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
DD4CBW23-X
Signal Format
PAL
Scanning System
Image Sensor
Effective Pixels
Horizontal Resolution
Lens
2:1 Interlace
1/4-inch progressive scan CCD
752 (H) X 582 (V)
540 TV lines
f/1.6 (focal length, 3.6~82.8 mm; 23X optical zoom, 12X digital zoom)
2.9/4.2/5.8 seconds
Zoom Speed
Horizontal Angle of View
Focus
54° at 3.6 mm wide zoom; 2.5° at 82.8 mm telephoto zoom
Automatic with manual override
Maximum Sensitivity at 35 IRE
0.025 lux at 1/1.5 sec. shutter speed (color)
0.1 lux at 1/50 sec. shutter speed (B-W)
0.004 lux at 1/1.5 sec. shutter speed (B-W)
Sync System
Internal/AC line lock, phase adjustable using remote control, V-Sync
White Balance
Shutter Speed
Iris Control
Automatic with manual override
Automatic (electronic iris)/manual; 1/1.5~1/30,000
Automatic iris control with manual override
Gain Control
Video Output
Video Signal-to-Noise
Wide Dynamic Range
Automatic/off
1 Vp-p, 75 ohms
>50 dB
80X
C3412M-D (12/08)
95
Download from Www.Somanuals.com. All Manuals Search And Download.
35X MODELS
DD4CBW35
Signal Format
NTSC
Scanning System
Image Sensor
2:1 Interlace/1:1 Progressive (user-selectable)
1/4-inch CCD
Effective Pixels
768 (H) X 494 (V)
Horizontal Resolution
Lens
Zoom Speed (optical range)
Horizontal Angle of View
Focus
>540 TV lines
f/1.4 (focal length, 3.4~119 mm; 35X optical zoom, 12X digital zoom)
3.2/4.6/6.6 seconds
55.8° at 3.4 mm wide zoom; 1.7° at 119 mm telephoto zoom
Automatic with manual override
Maximum Sensitivity at 35 IRE
0.55 lux at 1/60 sec. shutter speed (color)
0.063 lux at 1/4 sec. shutter speed (color)
0.00018 lux at 1/2 sec. shutter speed (B-W)
Sync System
Internal/AC line lock, phase adjustable using remote control, V-Sync
White Balance
Shutter Speed
Iris Control
Automatic with manual override
Automatic (electronic iris)/manual; 1/2~1/30,000
Automatic iris control with manual override
Gain Control
Video Output
Video Signal-to-Noise
Wide Dynamic Range
Automatic/off
1 Vp-p, 75 ohms
>46–50 dB
128X
96
C3412M-D (12/08)
Download from Www.Somanuals.com. All Manuals Search And Download.
DD4CBW35-X
Signal Format
PAL
Scanning System
Image Sensor
2:1 Interlace/1:1 Progressive (user-selectable)
1/4-inch CCD
Effective Pixels
Horizontal Resolution
Lens
752 (H) X 582 (V)
>540 TV lines
f/1.4 (focal length, 3.4~119 mm; 35X optical zoom, 12X digital zoom)
3.2/4.6/6.6 seconds
Zoom Speed
Horizontal Angle of View
Focus
55.8° at 3.4 mm wide zoom; 1.7° at 119 mm telephoto zoom
Automatic with manual override
Maximum Sensitivity at 35 IRE
0.50 lux at 1/50 sec. shutter speed (color)
0.062 lux at 1/3 sec. shutter speed (color)
0.00014 lux at 1/1.5 sec. shutter speed (B-W)
Sync System
Internal/AC line lock, phase adjustable using remote control, V-Sync
White Balance
Shutter Speed
Iris Control
Automatic with manual override
Automatic (electronic iris)/manual; 1/1.5~1/30,000
Automatic iris control with manual override
Gain Control
Video Output
Video Signal-to-Noise
Wide Dynamic Range
Automatic/off
1 Vp-p, 75 ohms
>46–50 dB
128X
The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002/95/EC.
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the
European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures
for recycling this equipment.
C3412M-D (12/08)
97
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in
material or workmanship for a period of one year after the date of shipment.
Pelco will warrant all replacement parts and repairs for 90 days from the date of
Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid
to a Pelco designated location. Repairs made necessary by reason of misuse,
alteration, normal wear, or accident are not covered under this warranty.
Exceptions to this warranty are as noted below:
•
•
Five years:
Pelco assumes no risk and shall be subject to no liability for damages or loss
resulting from the specific use or application made of the Products. Pelco’s
liability for any claim, whether based on breach of contract, negligence,
infringement of any rights of any party or product liability, relating to the
Products shall not exceed the price paid by the Dealer to Pelco for such
Products. In no event will Pelco be liable for any special, incidental, or
consequential damages (including loss of use, loss of profit, and claims of third
parties) however caused, whether by the negligence of Pelco or otherwise.
–
–
–
Fiber optic products
TW3000 Series unshielded twisted pair (UTP) transmission products
CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and
MC3651H-2X camera models
Three years:
–
Pelco-branded fixed camera models (CCC1390H Series, C10DN Series,
C10CH Series, and IP3701H Series)
–
–
–
–
EH1500 Series enclosures
The above warranty provides the Dealer with specific legal rights. The Dealer
may also have additional rights, which are subject to variation from state to
state.
Spectra® IV products (including Spectra IV IP)
Camclosure® Series (IS, ICS, IP) integrated camera systems
DX Series digital video recorders, DVR5100 Series digital video
recorders, Digital Sentry® Series hardware products, DVX Series digital
video recorders, and NVR300 Series network video recorders
Endura® Series distributed network-based video products
Genex® Series products (multiplexers, server, and keyboard)
PMCL200/300/400 Series LCD monitors
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100
or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the
following information:
–
–
–
1. Model and serial number
2. Date of shipment, P.O. number, sales order number, or Pelco invoice number
3. Details of the defect or problem
•
Two years:
If there is a dispute regarding the warranty of a product that does not fall
–
–
–
–
Standard motorized or fixed focal length lenses
DF5/DF8 Series fixed dome products
Legacy® Series integrated positioning systems
Spectra III™, Spectra Mini, Spectra Mini IP, Esprit®, ExSite®, and PS20
scanners, including when used in continuous motion applications.
Esprit Ti and TI2500 Series thermal imaging products
Esprit and WW5700 Series window wiper (excluding wiper blades).
CM6700/CM6800/CM9700 Series matrix
Digital Light Processing (DLP®) displays (except lamp and color wheel).
The lamp and color wheel will be covered for a period of 90 days. The
air filter is not covered under warranty.
Intelli-M® eIDC controllers
under the warranty conditions stated above, please include
explanation with the product when returned.
a
written
Method of return shipment shall be the same or equal to the method by which
the item was received by Pelco.
–
–
–
–
RETURNS
To expedite parts returned for repair or credit, please call Pelco at (800) 289-9100
or (559) 292-1981 to obtain an authorization number (CA number if returned for
credit, and RA number if returned for repair) and designated return location.
–
All merchandise returned for credit may be subject to a 20 percent restocking
and refurbishing charge.
•
•
One year:
Video cassette recorders (VCRs), except video heads. Video heads will
be covered for a period of six months.
Six months:
All pan and tilts, scanners, or preset lenses used in continuous motion
applications (preset scan, tour, and auto scan modes).
–
Goods returned for repair or credit should be clearly identified with the
assigned CA or RA number and freight should be prepaid
–
11-11-08
REVISION HISTORY
Manual #
C3412M
Date
9/06
Comments
Original version.
C3412M-A
C3412M-B
10/06
6/07
Upgraded 23X to Spectra IV SE and added 18X information. Corrected specifications. Revised SW2 Switches 4–5 section.
Corrected menus and Specifications. Added cross references. Added information about low light focus, event labels, and image
enhancement features.
C3412M-C
C3412M-D
11/07
12/08
Updated manual to reflect software version 1.070. Added DIP switch and progressive scan sections. Revised switch settings, type of
lighting, IR cut filter, and proportional pan settings.
Updated to reflect software version 1.090. Added new sections for sure focus, event types, low lux noise reduction, sensor scan mode,
and field align. Revised information regarding SW2-3, type of lighting settings, 18X and 23X specifications, auto white balance defaults,
and limitations to presets. Removed all references to 22X black-white models.
Pelco, the Pelco logo, Camclosure, Digital Sentry, Endura, Esprit, ExSite, Genex, Intelli-M, Legacy, and Spectra are registered trademarks of Pelco, Inc.
Spectra III is a trademark of Pelco, Inc.
© Copyright 2008, Pelco, Inc. All rights reserved.
DLP is a registered trademark of Texas Instruments Incorporated.
Vicon is a registered trademark of Vicon Industries, Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
Pelco, Inc. Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA
USA & Canada Tel (800) 289-9100 Fax (800) 289-9150
International Tel +1 (559) 292-1981 Fax +1 (559) 348-1120
Download from Www.Somanuals.com. All Manuals Search And Download.
|