1.0 WARNINGS
1.1 IMPORTANT SAFEGUARDS
Before installing your equipment, please read the following important safeguards
as outlined by Underwriters Laboratories Inc.
Read Instructions
All the safety and operating instructions should be read before the appliance is operated.
Retain Instructions
The safety and operating instructions should be retained for future reference.
Heed Warnings
All warnings on the appliance and in the operating instructions should be followed.
Follow Instructions
All operating and use instructions should be followed.
Cleaning
Do not use liquid cleaners or aerosol cleaners. Use a Damp Cloth for cleaning.
Attachments
Do not use attachments not recommended by Pelco as they may cause hazards.
Water and Moisture
Do not use this CCTV product near water - for example, near a kitchen sink, wash
bowl, bath tub, sprinkler, in a wet basement or near a swimming pool, and the like
unless it is specifically marked “for use in wet locations”.
Accessories
Do not place this CCTV product on an unstable cart, stand, tripod, bracket, or table.
The CCTV product may fall, causing serious injury to a child or adult, and serious
damage to the appliance. Use only with a cart, stand, tripod, bracket or table rec-
ommended by Pelco, or supplied by Pelco with the product. When mounting the
appliance, follow Pelco’s installation instructions, and use only mounting accesso-
ries recommended by Pelco.
Cart & Stand
An appliance and cart combination should be moved with care. Quick stops, excessive
force, and uneven surfaces may cause the appliance and cart combination to overturn.
Ventilation
Slots and openings in the cabinet are provided for ventilation and to ensure reliable
operation of the CCTV product, and to protect it from overheating. These openings
must not be blocked or covered. The openings should never be blocked by placing
the CCTV product on furniture, carpet, or similar surfaces. The CCTV product should
never be placed near or over radiators or heat registers. This CCTV product should
not be placed in a built-in installation, such as a book case or rack unless proper
ventilation is provided or Pelco’s installation instructions are adhered to.
Power Sources
This CCTV product should only be operated from the type of power source indi-
cated on the marketing label. If you are not sure of the type of power supply to your
installation location, consult your local electrical building official or power company.
Refer to the operating instructions for appliances intended to operate from battery
or other power sources.
Grounding
This CCTV product is equipped with a “grounding” type plug. This plug will only fit into
a “grounding” type power outlet. This is a safety feature. If you are unable to insert the
plug into the outlet, contact your electrician to replace your obsolete outlet. Do not
defeat the “grounding” type plug since it is provided to ensure your safety.
Pelco Manual C931M (12/96)
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Power-Cord Protection
Power-supply cords should be routed so that they are not likely to be walked on or
pinched by items placed upon or against them, paying particular attention to cords at
plugs, convenience receptacles, and the point where they exit from the appliance.
Overloading
Do no overload wall outlets and extension cords as this can result in a risk of fire or
electric shock.
Object and Liquid Entry
Never push objects of any kind into this CCTV product through openings as they
may touch dangerous voltage points or short-out parts that could result in a fire or
electric shock. Never spill liquid of any kind on the CCTV product.
Servicing
Do not attempt to service this CCTV product yourself as opening or removing cov-
ers may expose you to dangerous voltages or other hazards. Refer all servicing to
qualified service personnel.
Damage Requiring Servicing
Unplug this CCTV product from the wall outlet and refer servicing to qualified ser-
vice personnel under the following conditions:
a. When the power-supply cord or plug is damaged.
b. If liquid has been spilled, or objects have fallen into the CCTV product.
c. If the CCTV product is not marked “Suitable for Wet Locations” and it has
been exposed to rain or water.
d. If the CCTV product does not operate normally by following the operating
instructions. Adjust only those controls that are covered by the operating in-
structions as an improper adjustment of other controls may result in damage,
and will often require extensive work by a qualified technician to restore the
CCTV product to its normal operation.
e. If the CCTV product has been dropped or the cabinet has been damaged.
f.
When the CCTV product exhibits a distinct change in performance - this indi-
cates a need for service.
Replacement Parts
When replacement parts are required, be sure the service technician has used re-
placement parts specified by Pelco or have the same characteristics as the original
part. Unauthorized substitutions may result in fire, electric shock, or other hazards.
Safety Checks
Upon completion of any service or repairs to this CCTV product, ask the service
technician to perform safety checks to determine that the CCTV product is in proper
operating condition.
WARNING
This product has been evaluated for INDOOR USE ONLY unless it bears the mark-
ing FOR USE IN WET LOCATIONS.
WARNING
To reduce the risk of electric shock hazard, do not remove the cover of the unit. This
unit can not be serviced by the user and must be sent to a qualified service person
for repair when it fails to function.
The Lightning Flash with an arrow head symbol within an equilateral
triangle means that if the enclosure is opened, electrical circuitry is ex-
posed which imposes an electric shock hazard to persons present.
The Exclamation Point within an equilateral triangle means the operat-
ing instructions contain important information on how to operate and
maintain the appliance.
2
Pelco Manual C931M (12/96)
Download from Www.Somanuals.com. All Manuals Search And Download.
2.0 DESCRIPTION
The PMM901 and PMM1201 are high resolution, black and white, CCTV video
monitors. The cabinets are made of steel for ruggedness and, with the exception of
the picture tube, the circuitry is all solid-state for reliability.
2.1 MODELS
PMM901
Black and white monitor, 9-inch (22.86 cm) picture display, 120
VAC, EIA standard. (CSA)
PMM901-X
PMM1201
Black and white monitor, 9-inch (22.86 cm) picture display, 230
VAC, CCIR standard. (CSA, CE)
Black and white monitor, 12-inch (30.48 cm) picture display,
120 VAC, EIA standard. (CSA, UL)
PMM1201-X
Black and white monitor, 12-inch (30.48 cm) picture display,
230 VAC, CCIR standard. (CE)
Pelco Manual C931M (12/96)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
3.0 INSTALLATION
3.1 SURFACE MOUNT
The monitor has rubber feet and may be placed on any horizontal surface, such as
a desk or table.
3.2 RACK MOUNT
The monitor may be installed in a 19-inch (48.26 cm) rack using the following kits:
RMA901
RMA1201
Rack kit for one or two 9-inch (22.86 cm) monitors
Rack kit for one 12-inch (106.7 cm) monitor
Follow the instructions that accompany the rack kit.
3.3 CONNECTIONS
3.3.1 Single-Monitor Installation
Refer to Figure 1 and Table A for the following instructions.
1. Set the termination switch on the back of the monitor to 75 ohms.
2. Connect a 75-ohm video cable from the video source, such as a camera, to
the BNC connector labeled IN on the back of the monitor.
3. Plug in the power cord.
IMPEDANCE
75Ω HI
IN
OUT
Figure 1. Single-Monitor Installation
4
Pelco Manual C931M (12/96)
Download from Www.Somanuals.com. All Manuals Search And Download.
3.3.2 Multiple-Monitor Installation
Refer to Figure 2 and Table A for the following instructions.
NOTE: In multiple-monitor in-
stallations, a maximum of three
monitors can be connected to-
gether.
1. Connect a 75-ohm video cable from the video source, such as a camera, to
the BNC connector labeled IN on the back of the first monitor.
2. Connect a 75-ohm video cable from the OUT connector on the back of the first
monitor to the IN connector on the second monitor.
3. If you are using a third monitor, connect a 75-ohm video cable from the OUT
connector on the back of the second monitor to the IN connector on the third
monitor.
4. Set the termination switch on the first monitor to HI.
If you are only using two monitors, set the termination switch on the second
monitor to 75 ohms.
If you are using three monitors, set the termination switch on the second monitor
to HI and the on the third monitor to 75 ohms.
5. Plug in the power cords for the monitors.
Table A. Video Coaxial Cable Wiring Distances
Cable Type
Maximum Distance
RG59
RG6
RG11
750 ft (229 m)
1,000 ft (305 m)
1,500 ft (457 m)
MONITOR 1
MONITOR 2
MONITOR 3
TERMINATION
SWITCH SET
TO "HIGH"
TERMINATION
SWITCH SET
TO "HIGH"
TERMINATION
SWITCH SET
TO "75 OHMS"
FROM VIDEO
SOURCE TO INPUT
FROM OUTPUT
TO INPUT
FROM OUTPUT
TO INPUT
IMPEDANCE
75Ω HI
IN
OUT
NOTE: Set impedance switches
as appropriate for the number of
monitors in your configuration.
REAR PANEL OF MONITOR
3
Figure 2. Multiple Monitor Installation
Pelco Manual C931M (12/96)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
4.0 OPERATION
The controls are located behind the door on the front of the monitor beneath the
screen. Refer to Figure 3 for the locations of the controls.
Power On/Off Switch - This rocker switch turns the power on or off. Push the side
with the white dot to turn on the power. Push the opposite side to turn the power off.
LED Power Indicator - The LED lights when power is turned on.
Brightness Control - This control adjusts the overall picture brightness to com-
pensate for differences in room lighting.
NOTE: On the back of the
monitor there are adjust-
ments for vertical linearity,
vertical size, focus, and sub-
brightness. These are special
adjustments that should be
made only by qualified ser-
vice personnel.
Contrast Control - This control adjusts the contrast between the black and white
portions of the picture. When properly adjusted, you will be able to observe a fine
gradation between blacks, grays, and whites.
Vertical Hold Control - This control permits adjustment of vertical stability. If the
picture “rolls” upward or downward, as shown in Figure 4, turn the VERTICAL HOLD
clockwise or counterclockwise until the picture stabilizes.
Horizontal Hold Control - This control permits adjustment of horizontal stability. If
the picture “tears” to the left or right, as shown in Figure 5, turn the HORIZONTAL
HOLD clockwise or counterclockwise until the picture stabilizes.
To operate a monitor:
1. Make sure a standard 1.0 V peak-to-peak video signal is applied to the video
input of the monitor.
2. Press the power switch to turn on the power. The power indicator LED will
illuminate.
3. Adjust the brightness and contrast controls to obtain optimum picture quality.
Figure 3. Location of Controls
6
Pelco Manual C931M (12/96)
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 4. Vertical Roll
Figure 5. Horizontal Tear
Pelco Manual C931M (12/96)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
5.0 MAINTENANCE
The only maintenance required is to periodically clean the cabinet and screen.
Use a damp cloth to clean the screen.
Use mild soap and water to clean the cabinet. Some common household aerosol
sprays, cleaning agents, solvents, or polishes may damage the cabinet finish. Dry
the cabinet with a soft cloth.
6.0 SPECIFICATIONS
ELECTRICAL
Input Voltage:
PMM901,
PMM1201
120 VAC, 60 Hz
230 VAC, 50 Hz
PMM901-X,
PMM1201-X
Power Consumption:
PMM901,
PMM901-X
25 W
PMM1201,
PMM1201-X
30 W
Input Signal:
0.5 to 2.0 V peak-to-peak composite video, negative synchro-
nization
Input Impedance: 75 ohms or high (switchable)
Bandwidth:
Video Gain:
100 Hz to 10 MHz
30 dB
Resolution:
Center
Corner
1,000 lines
800 lines
Linearity:
Horizontal
Vertical
15% maximum
10%
Operating System:
EIA
Horizontal:
Vertical:
15,750 Hz ±400 Hz
60 Hz
CCIR
Horizontal:
Vertical:
15,625 Hz ±400 Hz
50 Hz
8
Pelco Manual C931M (12/96)
Download from Www.Somanuals.com. All Manuals Search And Download.
GENERAL
Environment:
Construction:
Finish:
Indoor
Steel cabinet with black plastic front
Black matte texture coat finish
Dimensions:
PMM901,
PMM901-X
8.9" W x 9.9" H x 9.3" D
(22.5 cm x 25.2 cm x 23.5 cm)
PMM1201,
PMM1201-X
12.2" W x 12.2" H x 12.2" D
(31.0 cm x 31.0 cm x 31.0 cm)
Picture Tube Dimension:
PMM901,
PMM901-X
9" (22.86 cm), measured diagonally
PMM1201,
PMM1201-X
12" (30.48 cm), measured diagonally
Operating
Temperature:
50° to 131° F (10° to 55° C)
Storage
Temperature:
-22° to 149° F (-30° to 65° C)
Humidity:
10 to 95 percent, non-condensing
Weight:
Unit
PMM901,
PMM901-X
13.2 lbs (6.0 kg)
14.6 lbs (6.6 kg)
PMM1201,
PMM1201-X
Shipping
PMM901,
PMM901-X
20.9 lbs (9.5 kg)
23.1 lbs (10.5 kg)
PMM1201,
PMM1201-X
Specifications subject to change without notice.
Pelco Manual C931M (12/96)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
7.0 WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or
workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
•
•
•
Five years on FT/FR8000 Series fiber optic products.
Three years on Genex® Series products (multiplexers, server, and keyboard).
Three years on Camclosure® and fixed camera models, except the CC3701H-2, CC3701H-2X,
CC3751H-2,CC3651H-2X,MC3651H-2,andMC3651H-2Xcameramodels,whichhaveafive-
year warranty.
•
•
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed
dome products.
•
Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, including when used in
continuous motion applications.
•
•
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).
Eighteen months on DX Series digital video recorders, NVR300 Series network video
recorders, and Endura™ Series distributed network-based video products.
•
•
One year (except video heads) on video cassette recorders (VCRs). Video heads will be
covered for a period of six months.
Sixmonthsonallpanandtilts,scannersorpresetlensesusedincontinuousmotionapplications
(that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment.
AllgoodsrequiringwarrantyrepairshallbesentfreightprepaidtoPelco,Clovis,California.Repairs
made necessary by reason of misuse, alteration, normal wear, or accident are not covered under
this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the
specific use or application made of the Products. Pelco’s liability for any claim, whether based on
breach of contract, negligence, infringement of any rights of any party or product liability, relating
totheProductsshallnotexceedthepricepaidbytheDealertoPelcoforsuchProducts. Innoevent
will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss
of profit and claims of third parties) however caused, whether by the negligence of Pelco or
otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have
additional rights, which are subject to variation from state to state.
Ifawarrantyrepairisrequired, theDealermustcontactPelcoat(800) 289-9100or(559)292-1981
to obtain a Repair Authorization number (RA), and provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall under the warranty
conditions stated above, please include a written explanation with the product when returned.
Methodofreturnshipmentshallbethesameorequaltothemethodbywhichtheitemwasreceived
by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800)
289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit,
and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number
and freight should be prepaid. Ship to the appropriate address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed
to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco, the Pelco logo, Camclosure, Esprit,
Genex, Legacy, and Spectra are registered
trademarks of Pelco.
Pelco c/o Expeditors
473 Eccles Avenue
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
Endura and ExSite are trademarks of Pelco.
© Copyright 1999, Pelco. All rights reserved.