HS1000 Dimension Drawing .......................................................................................................... 3
HB6000, HB6000/220, and HB6024 Assembly.............................................................................. 5
HS1000 Series Tamper Switch Installation .................................................................................... 6
HB6000/220 Heater/Blower Kit Wiring Diagram (230 VAC) ........................................................... 7
HB6000 Heater/Blower Kit Wiring Diagram (120 VAC) .................................................................. 7
HB6024 Heater/Blower Kit Wiring Diagram (24 VAC) .................................................................... 8
HS1000 Enclosure Exploded Assembly Diagram .......................................................................... 9
REVISION HISTORY
Manual #
C490M
Date
5/90
Comments
Original version.
C490M-A
12/94
Revised manual to include new exploded assembly
diagram, updated parts list, and modified wall mounting
instructions as per ECO# 93-245.
C490M-B
C490M-C
C490M-D
9/95
11/95
1/96
Revised to include wiring instructions for tamper switch
and metric equivalents for specifications.
Revised to include updated tamper switch/bracket part
numbers and exploded view diagram.
Revised to include tamper switch installation, specifica-
tion description and new part numbers per ECO 95-397.
Pelco, the Pelco Logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco.
Endura and ExSite are trademarks of Pelco.
© Copyright 1996, Pelco. All rights reserved.
Pelco Manual C490M-D (1/96)
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
(This page intentionally left blank.)
iv
Pelco Manual C490M-D (1/96)
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION/OPERATION
HS1000 HIGH-SECURITY
CAMERA ENCLOSURE
1.0 WARNINGS
3. OnlyusereplacementpartsrecommendedbyPelco.
Priortoinstallationanduseofthisproduct,thefollowing
WARNINGS should be observed.
4. The installation method and materials should be
capable of supporting 4 times the weight of the
enclosure, camera and lens combination.
1. Installation and servicing should only be done by
Qualified Service Personnel and conform to all
Local codes.
5. The camera and lens combination shall not exceed
2. Unless the unit is specifically marked as a NEMA
Type 3, 3R, 3S, 4, 4X, 6 or 6P enclosure, it is
designed for Indoor use only and it must not be
installed where exposed to rain and moisture.
20 lbs (9.06 kg).
The product may bear the following
marks:
This symbol indicates that dangerous voltage
constituting a risk of electric shock is present
within this unit.
This symbol indicates that there are important
operating and maintenance instructions in the
literature accompanying this unit.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
CAUTION:
TOREDUCETHERISKOFELECTRICAL
SHOCK, DO NOT REMOVE COVER. NO
USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
Please thoroughly familiarize yourself with the information in this manual
prior to installation and operation.
Pelco Manual C490M-D (1/96)
1
Download from Www.Somanuals.com. All Manuals Search And Download.
2.0 SCOPE
4.0 INSTALLATION
The information within this manual covers the installa-
tion of the HS1000 High Security Camera Enclosure.
Before installing the HS1000 to a wall/ceiling, make
certain that the mounting surfaces are able to support
the full weight of the enclosure, plus the camera/lens
and any other options, (i.e., speakers, infrared illumi-
nators, heater/blower kits and/or hoods).
Installation should be in accordance with all applicable
local and national electric codes, utilizing approved ma-
terials only.
The tilt table and the tilt table mounting bracket may
be removed to provide adequate clearance for mount-
ing the enclosure.
3.0 DESCRIPTION
The HS1000 is a large, high-security camera enclosure
designed for indoor “corner mount” installation for such
applications as parking garages, prisons, detention cells,
etc., requiring maximum protection from vandalism.
The front cover and bottom plate can be removed from
the mounting frame to simplify installation.
NOTE: The eight (8) to twelve (12) fasteners
required to secure the HS1000 to a wall/ceiling
(minimum 3/8-inch diameter fasteners
recommended) are not supplied.
Constructed of heavy gauge steel, the HS1000 will ac-
cept most 2/3-inch format cameras with fixed focal
length lenses ranging in size from 4 mm to 75 mm.
There is no exposed mounting hardware securing the
HS1000 to its mounting surface. Opening the enclo-
sure can only be accomplished with a specially designed
tool, eliminating the possibility of the enclosure being
opened by unauthorized personnel. In addition, a fac-
tory-installed tamper switch is mounted on the secured
access cover.
Designed to fit flush to the ceiling in a corner, an op-
tional hood (HS1000H) allows the HS1000 to be
mounted lower on the wall and still retain the integ-
rity of the enclosure. Provisions are made for mount-
ing 4-inch (10.16 cm) speakers on either side of the
enclosure. The hinged front is supplied with an im-
pact-resistant Lexan window with adequate area for
the installation of an infrared illuminator.
2
Pelco Manual C490M-D (1/96)
Download from Www.Somanuals.com. All Manuals Search And Download.
4.1 CEILING MOUNTING (FLUSH)
6. Make all appropriate connections (i.e., camera
power, video (coax), lens, speakers, infrared illu-
minators, heater/power kits).
To mount the enclosure to a wall/ceiling, perform the
following steps:
7. Position the camera and tighten the 1/4-20 fasten-
ers to secure the tilt table in place.
1. Open the front cover by removing the four (4) 1/4-
20 “Tampruf” screws.Aspecial socket is provided
(fits 1/4-inch square drive). The cover hinges down.
8. Close the cover and check that all components clear.
Secure the cover with the four (4) 1/4-20 “Tampruf”
screws provided.
2. Using the mounting bracket as a template, mark
and drill holes in the mounting surfaces.
3. Attach the enclosure with the required fasteners.
4. Route required cables through the back and/or top
of the enclosure.
5. Mount the camera/lens to the tilt table.
Figure 1. HS1000 Dimension Drawing
Pelco Manual C490M-D (1/96)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
4.2 MID-WALL MOUNTING
4.4 OPTIONAL HB6000, HB6000/220,
AND HB6024 HEATER/BLOWER KITS
To mount the enclosure mid-wall, use the optional hood,
HS1000H, and perform the following steps:
The HB6000, HB6000/220, and HB6024 heater/blower
kits require 120 VAC, 230 VAC, or 24 VAC respectively.
They provide 80 watts of heat which is thermostati-
cally controlled to turn on at 40°F (4.44° C) and turn
off at 60°F (15.56° C). They also provide internal air
circulation which is thermostatically controlled to turn
on at 110°F (43.33° C) and off at 80°F (26.67° C).
1. Follow steps 1-7 in Section 4.1.
2. Attach the hood to the enclosure with the required
fasteners provided (minimum 3/8" diameter rec-
ommended).
3. Close the cover and check that all components clear.
Secure the cover with the four (4) 1/4-20 “Tampruf”
screws provided.
4.4.1 Recommended Cable Size
CAUTION: When using a single power
source for both the camera and accessories,
the camera power consumption must be taken
into consideration when determining the wire
gauge.
4.3 SPEAKER INSTALLATION
The HS1000 provides two (2) positions for mounting
small speakers (3" x 3" bolt pattern) to be provided by
the user.
The cable sizes listed in the table below, should be con-
sidered as the minimum recommended sizes for use with
the combination of blower/heater/camera.
The speaker grills are shipped with a cover plate
mounted over each on the inside. This plate must be
removed prior to speaker installation.
NOTE: The speakers mount to the front cover
of the enclosure. Be sure to leave an adequate
loop of cable to allow the cover to be opened.
Recommended Cable Sizes
Model
Input Voltage
Consumption
Cable Size
Cable Distance
HB6000
120 VAC
90 watts
22 Awg
20 Awg
18 Awg
16 Awg
464.7 ft (141.6 m)
738.9 ft (225.2 m)
1,175.5 ft (358.7 m)
1,865.7 ft (568.7 m)
HB6000/220
HB6024
230 VAC
24 VAC
90 watts
90 watts
24 Awg
22 Awg
20 Awg
18 Awg
16 Awg
1,047.4 ft (319.2 m)
1,666.0 ft (507.8 m)
2,649.2 ft (807.5 m)
4,214.6 ft (1,284.6 m)
6,688.8 ft (2,038.7 m)
20 Awg
18 Awg
16 Awg
14 Awg
31.5 ft (9.6 m)
50.2 ft (15.3 m)
79.6 ft (24.3 m)
127.0 ft (38.7 m)
4
Pelco Manual C490M-D (1/96)
Download from Www.Somanuals.com. All Manuals Search And Download.
4.4.2 Heater/Blower Kit Installation
4.4.2.2 Blower/PCB Assembly
To install the HB6000/HB6000/220/HB6024, perform the
following steps (refer to Figure 2).
1. Open the cover.
2. On the HS1000, the blower/PCB bracket is designed
to attach to any two (2) adjacent studs used in retain-
ing the bottom plate.
4.4.2.1 Heater Assembly
1. Open the cover.
3. Remove any two adjacent nuts and washers retain-
ing the bottom plate to the mounting frame.
2. The heater bracket is designed to attach to any two
(2) adjacent studs used in retaining the window.
4. Place the blower/PCB bracket over the studs, then
replace and tighten the hardware.
3. Remove any two (2) adjacent nuts and washers on
both sides of the window.
4.4.2.3 Heater/Blower Wiring
4. Place the heater brackets on the studs, with the heat-
ers angled away from the window, then replace and
tighten the hardware.
The blower is factory wired to the PCB assembly. Con-
nect the heaters to the PCB assembly as shown in the
respective wiring diagrams (Figure 4, Figure 5, or Figure
6). Supply AC line voltage (230 VAC, 120 VAC, or 24
VAC) as shown.
Figure 2. HB6000, HB6000/220, and HB6024 Assembly
Pelco Manual C490M-D (1/96)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
4.5 ELECTRICAL CONNECTION
4.6.1 Tamper Switch Wiring
After the cable has been routed, all wire connections
should be made (i.e., video, lens, camera power, heaters).
A 6-position terminal block has been provided to assist
in this.
The tamper switch comes with both a “Normally Open”
contact and a “Normally Closed” contact.
For a “Normally Open” circuit, use the “open ” and “com-
mon” terminals; for a “Normally Closed” circuit, use the
“closed” and “common” terminals.
CAUTION: When a single power source is
used for both the camera and accessories, the
camera power consumption must be taken into
consideration when determining the wire gauge.
Also, make certain that all electrical connections
are done properly and meet electrical codes.
5.0 CARE AND MAINTENANCE
Maintenance performed at regular intervals will help pro-
long the operational life and appearance of the equipment.
Clean the Lexan window with a mild nonabrasive deter-
gent in water with a soft cloth regularly to maintain pic-
ture clarity. For a heavily soiled window, use vinyl cleaner.
4.6
TAMPER SWITCH INSTALLATION
The HS1000 enclosures come standard from the fac-
tory with a tamper switch installed. Should it become
necessary to install a replacement switch, refer to Fig-
ure 3 for the correct position of the bracket/switch and
perform the following steps:
NOTE: Pelco offers a 24-hour, seven-day-a
week Technical Assistance Program (TAP)
designed to assist any customer with a technical
problem involving Pelco equipment whether it’s
the weekend or late at night. For technical
assistance dial (800) 289-9100 and you will be
connected to a PelcoTAPmember who is trained
to answer your questions.
1. Remove the front cover.
2. Install the bracket/switch and secure with
lockwashers and nuts.
Pelco also guarantees one-day turnaround on any Pelco
equipment sent in for repair. This includes warranty and
non-warranty items. Refer to the section on warranty and
return information in this manual for the proper proce-
dure.
Figure 3. HS1000 SeriesTamper Switch Installation
6
Pelco Manual C490M-D (1/96)
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 4. HB6000/220 Heater/Blower Kit Wiring Diagram (230 VAC)
Figure 5. HB6000 Heater/Blower Kit Wiring Diagram (120 VAC)
Pelco Manual C490M-D (1/96)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 6. HB6024 Heater/Blower Kit Wiring Diagram (24 VAC)
6.0 MECHANICAL PARTS LIST FOR HS1000 ENCLOSURE (FIGURE 7)
Item No.
Qty
Description
Part Number
1
2
1
2
Plate, Cover, Front
HS10004013COMP
HS80004115COMP
HS100010009
Plate, Grill, Block-Off
3
1
Window, HS1000, Clear, 12" x 15" x .50"
Switch, Tamper
Bracket, Switch, Break-In
Bracket, Mounting
Hood, Mid Wall Mount (optional accessory)
Tilt Table
Bracket, Tilt Table Mount
4
1
SWI1DM401
5
1
HS10004313COMP
HS10004011COMP
HS1000H
AH80004013COMP
AH80004014COMP
HS10004005COMP
HS10004008COMP
ZH1/4-20NUTCH
ZH1/4WSSL
ZH260X562X65C
ZH1/420NUTCHN
ZH255X1.50X62
ZH1/420X.625CH
ZH10-32NUTSH
ZH10LWSSL
6
1
7
1
8
1
9
1
10
11
A
B
C
D
E
F
G
H
I
1
Plate, Bottom, Corner Mount
Hinge, Cover
1
11
13
17
6
1/4-20 Hex, Finished Nut SS
Washer, Split Lock, 1/4-inch SS
Washer, Flat, 3/16-inch SS
Nut Lock 1/4-20 Nylon Insert Lock Nut
Washer, Fender, 1/4-inch Black Oxide
Bolt, 1/4-20 x 5/8-inch, Hex C/S SS
Nut, Hex, 10-32 SS
Washer, Split Lock, #10 SS
Washer, Flat, #10 SS
Screw, 1/4-20 x 1/2", Round, Tampruf, #10 SS
6
2
4
4
4
ZH204X436X60C
ZH1/4-20X.50SRT
J
4
8
Pelco Manual C490M-D (1/96)
Download from Www.Somanuals.com. All Manuals Search And Download.
7.0 EXPLODED ASSEMBLY DIAGRAM
Figure 7. HS1000 Enclosure Exploded Assembly Diagram
Pelco Manual C490M-D (1/96)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
8.0 SPECIFICATIONS
MECHANICAL
9.0 MODELS
The HS1000 high-security corner mount enclosure has
been designed for installations such as parking garages,
prisons, detention cells and many other areas requiring
maximum protection from vandalism. Below is a list
of available HS1000 enclosure options.
Window:
1/2" (12.7 mm) thick impact and
abrasion resistant clear Lexan
Camera
Mounting:
Adjustable tilt table
9.1 OPTIONS
Maximum
Camera/Lens
Size:
HS1000H
Hood for mid-wall mounting of
HS1000 enclosure.
Accepts camera/lens combinations
(including BNC connector) up to:
12.0" L x 6.0" W x 6.0" H
HB6000
120 VAC thermostatically controlled
heater and blower.
(30.48 cm x 15.24 cm x 15.24 cm)
Provides 80 watts of heat: activates
ON at 40°F (4.44° C); and OFF at
60°F (15.56° C).
Enclosure
Mounting:
Twelve (12) .390" (0.99 cm) diam-
eter holes on protected rear surfaces
(top and back)
Provides internal air circulation: ac-
tivates ON at 110°F (43.33° C); and
OFF at 80°F (26.67° C).
Security:
Tamper-resistant screws
N.O./N.C. switch contact on cover
HB6000/220
HB6024
Same as HB6000 except operates at
230 VAC.
Tamper Switch: Plunger type door switch with “pull
to cheat” feature. N.O./N.C. contacts
clearly marked on body of switch.
DM electrical rating: 10A, 125V.
Plunger type with .20" (0.51 cm)
Same as HB6000 except operates at
24 VAC.
ELECTRICAL
Cable Entry:
Six-position terminal block. Cable
entry access through back and top
Tamper Switch: 1/4" (.63 cm) quick connect. N.O./
N.C. clearly marked on switch body.
10A, maximum switching current
125V, maximum switching voltage.
GENERAL
Construction:
Formed 10 gauge .134" (0.34 cm)
steel
Finish:
Poly vinyl powder coat
See Figure 1
Dimensions:
Environment:
Unit Weight:
Indoor, 32° to 120° F (0° to 48.89° C)
40 lbs 13 oz (18.36 kg)
10
Pelco Manual C490M-D (1/96)
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes:
Pelco Manual C490M-D (1/96)
11
Download from Www.Somanuals.com. All Manuals Search And Download.
10.0 WARRANTY AND RETURN
INFORMATION
WARRANTY
RETURNS
Pelco will repair or replace, without charge, any merchandise proved
defectiveinmaterialorworkmanshipforaperiodofoneyearafterthedate
of shipment.
In order to expedite parts returned to the factory for repair or credit, please
call the factory at (800) 289-9100 or (559) 292-1981 to obtain an
authorization number (CA number if returned for credit, and RA number
if returned for repair).
Exceptions to this warranty are as noted below:
All merchandise returned for credit may be subject to a 20% restocking
and refurbishing charge.
•
•
Five years on FT/FR8000 Series fiber optic products.
Three years on Genex® Series products (multiplexers, server, and
keyboard).
Three years on Camclosure® and fixed camera models, except the
CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2,
and MC3651H-2X camera models, which have a five-year warranty.
Goods returned for repair or credit should be clearly identified with the
assigned CA or RA number and freight should be prepaid. Ship to the
appropriate address below.
•
If you are located within the continental U.S., Alaska, Hawaii or Puerto
Rico, send goods to:
Service Department
Pelco
•
•
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and
DF5/DF8 Series fixed dome products.
Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, includ-
ing when used in continuous motion applications.
Two years on Esprit® and WW5700 Series window wiper (excluding
wiper blades).
3500 Pelco Way
Clovis, CA 93612-5699
•
•
•
If you are located outside the continental U.S., Alaska, Hawaii or Puerto
Rico and are instructed to return goods to the USA, you may do one of the
following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Eighteen months on DX Series digital video recorders, NVR300
Series network video recorders, and Endura™ Series distributed
network-based video products.
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
•
•
One year (except video heads) on video cassette recorders (VCRs).
Video heads will be covered for a period of six months.
If the goods are to be sent by a FREIGHT FORWARDER, send the goods
to:
Six months on all pan and tilts, scanners or preset lenses used in
continuousmotionapplications(thatis,presetscan,tourandautoscan
modes).
Pelco c/o Expeditors
473 Eccles Avenue
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
Pelco will warrant all replacement parts and repairs for 90 days from the
date of Pelco shipment. All goods requiring warranty repair shall be sent
freight prepaid to Pelco, Clovis, California. Repairs made necessary by
reason of misuse, alteration, normal wear, or accident are not covered
under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or
loss resulting from the specific use or application made of the Products.
Pelco’s liability for any claim, whether based on breach of contract,
negligence, infringement of any rights of any party or product liability,
relating to the Products shall not exceed the price paid by the Dealer to
Pelco for such Products. In no event will Pelco be liable for any special,
incidental or consequential damages (including loss of use, loss of profit
and claims of third parties) however caused, whether by the negligence
of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The
Dealer may also have additional rights, which are subject to variation from
state to state.
Ifawarrantyrepairisrequired,theDealermustcontactPelcoat(800) 289-
9100 or (559) 292-1981 to obtain a Repair Authorization number (RA),
and provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice
number
3. Details of the defect or problem If there is a dispute regarding the
warranty of a product which does not fall under the warranty conditions
stated above, please include a written explanation with the product
when returned.
Method of return shipment shall be the same or equal to the method by
which the item was received by Pelco.
12
Pelco Manual C490M-D (1/96)
Download from Www.Somanuals.com. All Manuals Search And Download.
|