INSTALLATION/OPERATION
®
110 Series Camclosure
Integrated Camera System
With LowLight™ DSS Technology
®
C2404M-A (4/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
Important Safety Instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s
instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other
apparatus (including amplifiers) that produce heat.
9. Only use attachments/accessories specified by the manufacturer.
10. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold
with the apparatus. When a cart is used, use caution when moving the cart/apparatus
combination to avoid injury from tip-over.
11. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has
been damaged in any way, such as power-supply cord or plug is damaged, liquid has been
spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
12. Installation should be done only by qualified personnel and conform to all local codes.
13. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is
designed for indoor use only and it must not be installed where exposed to rain and moisture.
14. Use only installation methods and materials capable of supporting four times the maximum
specified load.
15. Use stainless steel hardware to fasten the mount to outdoor surfaces.
16. To prevent damage from water leakage when installing a mount outdoors on a roof or wall,
apply sealant around the bolt holes between the mount and mounting surface.
17. CAUTION: These servicing instructions are for use by qualified service personnel only.
To reduce the risk of electric shock do not perform any servicing other that contained in the
operating instructions unless you are qualified to do so.
18. Only use replacement parts recommended by Pelco.
19. The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage
CAUTION:
constituting a risk of electric shock is present
within this unit.
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
This symbol indicates that there are important
operating and maintenance instructions in the
literature accompanying this unit.
C2404M-A (4/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
3
REGULATORY NOTICES
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However there is no guarantee that the
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
•
Consult the dealer or an experienced radio/TV technician for help.
You may also find helpful the following booklet, prepared by the FCC: “How to Identify and Resolve
Radio-TV Interference Problems.” This booklet is available from the U.S. Government Printing Office,
Washington D.C. 20402.
Changes and modifications not expressly approved by the manufacturer or registrant of this
equipment can void your authority to operate this equipment under Federal Communications
Commission’s rules.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
4
C2404M-A (4/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
Welcome
Thank you for purchasing Pelco’s Camclosure® integrated camera system with LowLight™,
DSS (digital slow shutter) technology. Your new ICS110 Series surface mount dome system includes
a high resolution, low light, color camera with auto iris and varifocal lens.
The LowLight color camera has extended DSS settings to enhance the low light performance of the
camera by automatically adjusting the number of fields of integration. This slows the picture frame
rate and increases the camera’s sensitivity in low light conditions.
Prior to installation and operation of your new system thoroughly familiarize yourself with
the information in this manual.
C2404M-A (4/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
5
Installation
MOUNTING DIRECTLY TO SURFACE
WIRING THROUGH BASE
Follow the proceeding steps when feeding wire/cables through the base of the cover and back box:
1. Using the cover as a template, mark one
of the large hole positions onto the
mounting surface.
COVER
2. Cut out the hole in the mounting surface
for power and video wiring.
3. Pull video and power wires through the
hole in the cover.
4. Attach the cover to the mounting surface
(hardware not supplied). Use stainless
BACK BOX
steel hardware when installing the
system outdoors.
5. Connect the video cable.
6. Connect the power wires.
•
•
Red wire - 24 VAC/12 VDC
Black wire - GND
7. Install the back box inside the cover. Rotate and position the back box so that the conduit plug
on the side of the box is located on the opposite side (180 degrees) from the notch on the side
of the cover. Use the supplied 8-32 x 0.375-inch screws and washers to secure the back box to
the cover
NOTE: For vandal-resistant installations, the conduit plug located on the side of the back box
should be hidden if it is not used. To hide the conduit plug rotate the back box so that the plug
is located on the opposite side (180 degrees) from the notch on the side of cover.
6
C2404M-A (4/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING THROUGH SIDE CONDUIT
Follow the proceeding steps when feeding wire/cables through the side conduit opening of the unit:
1. Attach the cover to the mounting surface (hardware not supplied). Use stainless steel
hardware when installing the system outdoors.
2. Remove the conduit plug from the side of the back box.
3. Use a blunt tool to pull the wires and plug, located on the base of the back box into the back
box. Insert the black plug (supplied) into the hole in the base of the back box.
4. Install the back box inside the cover. Rotate and position the back box so that the conduit hole
on the side of the back box is aligned with the side notch of the cover. Use the supplied
8-32 x 0.375-inch screws and washers to secure the back box to the cover.
5. Install a 0.75-inch (1.91 cm) conduit fitting in the conduit hole of the back box.
6. Connect the video cable.
7. Connect the power wires.
•
•
Red wire - 24 VAC/12 VDC
Black wire - GND
MOUNTING TO A 4S ELECTRICAL BOX
1. Attach the ICS110-AP adapter plate (not supplied) to a 4S box with the two 8-32 x 0.75-inch
flat head screws supplied with the adapter plate.
2. Pull the video and power wires into the cover, and then attach the cover to the adapter plate
with the three supplied 8-32 x 0.375-inch pan head screws.
3. Connect the video cable.
4. Connect the power wires.
•
•
Red wire - 24 VAC/12 VDC
Black wire - GND
5. Install the back box inside the cover. For vandal-resistant installations, rotate and position the
back box so that the conduit plug on the side of the box is located on the opposite side (180
degrees) from the notch on the side of the cover. Use the supplied 8-32 x 0.375-inch screws
and washers to secure the back box to the cover.
MOUNTING TO A PLASTER RING
1. Pull video and power wires into the cover, and then attach the cover to a 404 plaster ring. Use
the two supplied 6-32 x 0.75-inch flat head screws to attach the cover to a 404 plaster ring.
2. Connect the video cable.
3. Connect the power wires.
•
•
Red wire - 24 VAC/12 VDC
Black wire - GND
4. Install the back box inside the cover. For vandal-resistant installations, rotate and position the
back box so that the conduit plug on the side of the box is located on the opposite side (180
degrees) from the notch on the side of the cover. Use the supplied 8-32 x 0.375-inch screws
and washers to secure the back box to the cover.
C2404M-A (4/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
7
Install the Camera Module
CHECK HEATER JUMPER
The Camclosure is equipped with a heater to defrost the dome. Some installations may not require
this heater. If the unit will never be subjected to a frost temperature, you can disable the heater,
saving power. To disable the heater, remove the jumper cover from the heater jumper block. It is
recommended that the jumper cover be left in the unit by installing it on one of the jumper pins.
CAMERA CONNECTOR
HEATER JUMPER
8
C2404M-A (4/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALL AND POSITION THE CAMERA
1. Plug the video connector from the camera into the mating connector inside the back box.
2. Position the camera so that the tab on the camera bracket is pointing out of the enclosure,
away from the ceiling or wall. Refer to the following illustrations for proper
camera orientation.
CAMERA BRACKET
TAB ALWAYS POINTS
OUT OF THE
TOP OF
CAMERA
ENCLOSURE
CAMERA BRACKET
TAB ALWAYS POINTS
OUT OF THE
ENCLOSURE
Wall Mounting – The camera bracket
tab points out of the enclosure and the
top of the camera points up towards
the tab.
Ceiling Mounting – The camera bracket tab
points out of the enclosure and the top of the
camera is pointed in the opposite direction.
3. Install the camera bracket. Gently squeeze the bracket, place it against the shoulder inside the
back box, and gently release.
4. Turn on power to the camera and monitor.
C2404M-A (4/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
9
MAKE CAMERA SETTINGS
CAUTION: Heater elements could be hot! When camera power is on, use caution when
adjusting the camera. This applies to all models.
ON
OFF
WHITE INDICATES
SWITCH SETTING
LEVEL
PHASE
ZOOM
N
FOCUS
T
W
ZOOM/FOCUS
1. Select a field of view by turning the zoom adjustment ring.
2. Tighten the zoom locking screw.
3. Adjust the focus by moving the focus locking screw clockwise/counterclockwise.
4. Tighten the focus locking screw.
DIGITAL SLOW SHUTTER (DSS)
Digital slow shutter slows the picture frame rate and increases the camera sensitivity under low light
conditions. Depending on the number of fields of integration, the picture will develop a granular
appearance and motion may show some lag, resulting in a stereoscopic effect or streaking on fast
moving objects. These effects increase as the number of fields of integration increase.
Available settings include the following:
ON OFF
30 fields of integration maximum (default setting) – 1/2-second scene update rate.
16 fields of integration maximum – 1/4-second scene update rate.
4 fields of integration maximum – 1/15-second scene update rate.
OFF – Disables the DSS mode.
Digital slow shutter automatically adjusts the number of fields of integration depending on the light
level of the viewed scene, up to the maximum determined by the switch settings.
10
C2404M-A (4/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
AGC (AUTOMATIC GAIN CONTROL)
AGC automatically adjusts the image to compensate for changes in light levels.
ON (Default setting) – Enables the AGC mode.
OFF – Disables the AGC mode.
BLC (BACK LIGHT COMPENSATION)
The BLC (backlight compensation) feature compensates for backlit scenes by enhancing objects in the
center of the scene.
OFF (Default setting) – Disables the BLC mode.
ON – Enables the BLC mode. Use this setting if a bright backlight is present and the subject in the
center of the picture appears dark or as a silhouette.
VERTICAL PHASE ADJUSTMENT (24 VAC OPERATION ONLY)
When using more than one camera power supply, a brief vertical roll may occur on the monitor when
a camera view is switched. To eliminate vertical roll reverse the 24 VAC connections on one camera.
If both cameras are connected to the same transformer, this should solve the problem. If reversing the
connections does not solve the problem, adjust the phase control by synchronizing, or line-locking, the
cameras to one another.
How to Adjust the Phase Control
It may be necessary to have two people in communication when synchronizing the cameras: one
person at the camera and another person at the monitor to observe the vertical roll and the effect of
any adjustments made at the camera.
To synchronize the cameras:
1. Choose a reference camera to which all other cameras will be phased.
2. Select a camera and synchronize it to the reference camera by turning the phase adjustment
control clockwise and/or counterclockwise.
3. Each time an adjustment is made, switch back and forth between the camera you are
adjusting and the reference camera. Repeat this process as many times as necessary, until the
roll between the cameras is no longer noticeable.
4. Adjust the phase of all other cameras by repeating steps 2 through 3. Always adjust to the
reference camera selected in step 1.
NOTE: The preferred method for camera phase adjustment is to use a dual trace oscilloscope
to align the vertical synchronization pulses of the reference camera to the selected camera(s).
VARIFOCAL LENS AUTO IRIS LEVEL ADJUSTMENT
To adjust the auto iris level, turn the level adjustment counterclockwise to decrease the brightness
level and clockwise to increase the brightness level.
C2404M-A (4/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
11
Install Dome and Trim Ring
1. Domes with Liners: Position the viewing window over the lens of the camera.
a. Loosen the three Phillip screws located in the dome.
b. Insert the blade of a standard screwdriver in one of the adjustment grooves. Move the
dome into position.
c.
Tighten the three Phillip screws to lock the liner in place.
2. Align the screw holes in the trim ring with those in the Camclosure base.
3. Tighten the tamper-resistant screws with the supplied 1/8-inch hollow screwdriver bit.
ADJUSTMENT
GROOVE
DOME LINER
LOOSEN SCREWS
12
C2404M-A (4/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
Backbox
Electrical
Input Voltage
Power Consumption
Video Connector
12 VDC or 24 VAC, 10%, auto-sensing
13 watts or less
BNC
General
Operating Temperature
-50° to 122°F (-46° to 50°C)
De-ices to 25°F (-4°C)
Pan/Tilt Adjustment:Manual 360° pan; 180° tilt
Construction
Finish
Environment
Weight
Aluminum with steel camera mounting bracket and polycarbonate dome
Light gray polyester powder coat
Indoor/outdoor
2.20 lb (1.0 kg)
Camera
Signal System
Imaging Device
Resolution
NTSC/PAL
1/3-inch interline transfer CCD
480 TV lines
Min. Illumination
0.75 lux at 40 IRE, DSS off, f1.6 at wide angle
1.20 lux at 50 IRE, DSS off, f1.6 at wide angle
0.025 lux at 40 IRE, 30 fields of DSS, f1.6 at wide angle
0.040 lux at 50 IRE, 30 fields of DSS, f1.6 at wide angle
2.6-6.0 mm or 4.0–9.0 mm varifocal, D-mount, f1.6
Adjustable AC line lock/internal, auto select
Electronic/automatic
Lens
Synchronize
Iris Control
Signal to Noise
AGG
50 dB
Selectable, ON/OFF
BLC
DIP switch
selectable, ON/OFF
5.50
(13.97)
Auto Iris Type
Shutter
DC drive
1/60–1/100,000
electronic, auto
1.76
(4.47)
2.36
(6.00)
Video Level
Adjustable
4.01
(10.19)
3.79
(9.63)
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS;
ALL OTHERS ARE INCHES.
(Design and product specifications subject to change without notice.)
C2404M-A (4/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
13
14
C2404M-A (4/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of
shipment.
Exceptions to this warranty are as noted below:
•
•
•
Five years on FT/FR8000 Series fiber optic products.
Three years on Genex® Series products (multiplexers, server, and keyboard).
Three years on Camclosure® and fixed camera models, except the CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and
MC3651H-2X camera models, which have a five-year warranty.
•
•
•
•
•
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed dome products.
Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, including when used in continuous motion applications.
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).
Eighteen months on DX Series digital video recorders, NVR300 Series network video recorders, and Endura™ Series distributed network-based video
products.
•
•
One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.
Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight
prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this
warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s
liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products
shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential
damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state
to state.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and
provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written
explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization
number (CA number if returned for credit, and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate
address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the
following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco
Pelco c/o Expeditors
473 Eccles Avenue
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
3500 Pelco Way
Clovis, CA 93612-5699 USA
REVISION HISTORY
Manual #
C2404M
C2404M-A
Date Comments
2/05 Original version.
4/05 Replaced 8-32 x 0.5-inch screws with 8-32 x 0.375-inch screws per ECO 05-10876.
©Copyright 2005, Pelco.
All rights reserved.
Camclosure, Pelco, the Pelco logo, and Coaxitron are registered trademarks of Pelco.
LowLight is a trademark of Pelco.
Download from Www.Somanuals.com. All Manuals Search And Download.
Worldwide Headquarters
3500 Pelco Way
Clovis, California 93612 USA
USA & Canada
Tel: 800/289-9100
Fax: 800/289-9150
International
Tel: 1-559/292-1981
Fax: 1-559/348-1120
ISO9001
United States Canada United Kingdom The Netherlands Singapore Spain Scandinavia France Middle East
|
|
|
|
|
|
|
|
Download from Www.Somanuals.com. All Manuals Search And Download.
|