Q U I C K S TA R T G U I D E
DX3100 Series
Digital Video Recorder
®
C695M-QS (12/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
DX3100 SERIES DIGITAL VIDEO RECORDER
This guide provides basic information for installing, configuring, and using the DX3100 Series digital video recorder. For detailed information, refer to
the DX3100 Installation/Operation manual.
HARDWARE INSTALLATION
After you place the unit in a rack or on a desktop, set the switches and make the connections as listed:
ᕡ
ᕢ
ᕣ
ᕤ
ᕥ
ᕦ
ᕧ
ᕨ
Set the correct voltage: 115V or 230V.
Set the video format switch: NTSC or PAL.
Connect the cameras. Also connect any looping outputs.
Connect the monitor.
Connect the power cable.
Connect alarm inputs and outputs.
If you will access the unit over a network, connect a network cable to the LAN port.
If installing Spectra, Esprit, or other PTZ:
8a Connect the RS-232 to RS-422/RS-485 converter.
8b Connect power to the converter.
8c Connect camera control cabling to the converter.
4
3
2
1
5
6
1
9
2
3
4
5
6
7
8
MON OUT
IN
10
11
12
13
14
15
16
G 1
2
3
4
G
1
2
NTSC
PAL
IN
OUT ALARM
VERIFY THAT
THE VOLTAGE IS
SET CORRECTLY
(115V/230V)
115V
230V
LAN
P/T/Z
SERIAL
OUT 1-8
OUT 9-16
RC
DX31 16-XX
8
a
8
c
7
USA STANDARD
EUROPEAN STANDARD
ADAPTER
RS-232 TO
RS-422/RS-485
CONVERTER
POWER
ADAPTER
SPECTRA®
ESPRIT®
8
b
Rx-
Rx-
Rx+
Rx+
DAISY-CHAIN HOOKUP FOR PTZ CAMERAS
C695M-QS (12/03)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
FRONT PANEL OPERATION
NOTE: For complete information about the front panel and the IR remote controller, refer to the DX3100 Installation/Operation manual.
The buttons for each section below are shaded in the associated figures.
General
ᕡ
ᕢ
ᕣ
ᕤ
ᕥ
Power switch (startup and shutdown)
Toggle on-screen display (OSD)
Sequence
Activate multi-screen views: ꢀ for 1x1, ꢁ for 2x2, ꢂ for 3x3, ꢃ for 4x4 (DX3116)
Display selected camera (1-8 or 1-16)
Setup
ᕦ
Enter and exit setup mode; exit submenus
NOTE: The default password is 1981.
Select submenu or edit field
ᕧ
ᕨ
ᕩ
Field selection and edit: ꢄ, ꢅ, ꢆ, ꢇ
Edit password (DX3116): buttons 1-9 = numbers 1-9, button 10 = 0
ᕫᕾ Edit password (DX3108): buttons 1-8 = numbers 1-8,
button ꢀ = number 9, button ꢁ = number 0
Playback
ᕫᕵ Enter and exit playback mode
ᕫᕶ VCR-style controls for video playback
ᕫᕷ Display event list
ᕫᕸ Field selection/edit: ꢄ, ꢅ, ꢆ, ꢇ, ENTER
ᕫᕹ Display video from selected camera (1-8 or 1-16)
ᕫᕺ Save image to floppy disk
PTZ
19 20
17
18
21 22 23
ᕫᕻ Enter and exit PTZ mode
ᕫᕼ Toggle on-screen display (OSD)
ᕫᕽ Zoom control: ZM WIDE, ZM TELE
ᕬᕾ PTZ directional movement: ꢀ, ꢄ, ꢁ, ꢆ, ꢇ, ꢂ, ꢅ, ꢃ
ᕬᕵ Enter and exit focus and iris controls
ᕬᕶ Focus controls: FOCUS NEAR, FOCUS FAR
ᕬᕷ Iris controls: IRIS CLOSE, IRIS OPEN
Z
WIDE
Z
FOCUS
FN
FDD
P/T/Z OSD
EVENT
SEQ
FOCUS
NEAR
ZM
WIE
ZM
TELE
FDD
P/T/Z OSD
EVENT
SEQ
FOCUS
NEAR
FOCUS
FAR
TELE
F
FAR
IRIS
CLOSE
IRIS
OPEN
IRIS
CLOSE
IRIS
OPEN
ENTER
ENTER
PLAYBACK
SETUP
PLAYBACK
SETUP
POWER
POWER
RETURN
RETURN
RETURN
RETURN
4
C695M-QS (12/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
CONFIGURATION
ᕢ
To configure the DX3100:
ᕡ
ᕢ
Press SETUP.
Use the camera buttons to enter the four-digit password. The default is 1981. The setup menu
appears.
ᕣ
Change the default DX3100 settings:
a. Select RECORDER SETUP on the setup menu and then press ENTER.
b. Change any of the following DX3100 settings:
ᕣ
•
•
•
•
•
IMAGE SIZE: The default is 352 X 240.
IMAGE RATE: The default is either 8 ips (DX3108) or 16 ips (DX3116).
TIME/DATE SET: The default is set at the factory.
DAYLIGHT SAVING: The default is US.
PTZ PROTOCOL: The default is NONE.
c. Press SETUP to return to the setup menu.
ᕤ
Configure the settings for each camera:
a. Select CAMERA SETUP on the setup menu and then press ENTER.
b. Press ꢅ (down arrow) to select the camera and press ENTER.
c. Change any of the following default camera settings:
ᕤ
NOTE: Select MANUAL to change any setting under RECORD PARAMETER.
•
•
•
•
•
CAMERA NAME: The default name for each channel: CH1 to CH16.
RECORD TIME: The default is 0 to 24.
IMAGE QUALITY: The default is 70.
MOTION SENSITIVITY: The default is 100.
PTZ RX ADDRESS: The default is 0.
d. Press SETUP to return to the setup menu.
ᕥ
ᕥ
ᕦ
Configure the network settings (optional):
a. Select NETWORK SETUP on the setup menu and then press ENTER.
b. Enter the network address information for the DX3100: IP ADDRESS, SUBNET MASK
and GATEWAY.
NOTE: You may also set the network password for this DX3100.
c. Press SETUP to return to the setup menu.
Press SETUP to exit the setup menu.
C695M-QS (12/03)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
SETTING SYSTEM DATE AND TIME
ᕡ
ᕢ
ᕣ
Press SETUP.
Use the camera buttons to enter the four-digit password. The default is 1981. The setup menu appears.
Select RECORDER SETUP and then press ENTER.
ᕤ
Update the daylight saving time setting (optional). The default is US.
a. Select DAYLIGHT SAVING and then press ENTER.
b. To disable daylight saving time processing, press ꢄ (up arrow) or ꢅ (down arrow) to select NONE and then press ENTER.
c. To enable daylight saving time processing for a different country, press ꢄ (up arrow) or ꢅ (down arrow) to select the country and then
press ENTER.
ᕥ
ᕦ
Select the time format (optional):
a. Select TIME FORMAT and then press ENTER.
b. Press ꢄ (up arrow) or ꢅ (down arrow) to select AM/PM or 24HR.
c. Press ENTER.
Set the system date and time:
a. Select TIME/DATE SET and then press ENTER.
b. Press ꢇ (right arrow) to select a field to change: day, month, day, year, AM/PM, hours, minutes, or seconds.
c. Press ꢄ (up arrow) or ꢅ (down arrow) to change the field value.
d. When the date and time are correct, press ENTER.
ᕧ
ᕨ
Press SETUP to return to the setup menu.
Press SETUP again to exit the setup menu.
6
C695M-QS (12/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
DX3100RX REMOTE SITE SOFTWARE
NOTE: Before installing this software, refer to the DX3100 Series Remote Site Software manual for minimum system requirements.
NOTE: This Quick Start Guide is written for installers who are familiar with the Windows® operating system.
Installation
ᕡ
ᕢ
ᕣ
Insert the Remote Site Software CD that came with the DX3100.
Follow the on-screen prompts, specifying default program folder.
Restart the computer.
Configuration
ᕡ
Launch the Remote Site Software:
Start > Program > DX3100RX > DX3100RX v1.0.
ᕢ
ᕣ
Click OK on the Input password screen. You can add a password later.
Create a site for the DX3100:
a. Click CONNECT. The Site/File Open screen appears.
b. Click Add. The Connection Property (New) screen appears.
c. Do the following:
•
•
Site Name: Enter the site name for this DX3100. It appears on the screen when you access the site.
Server IP: Enter the network address for the DX3100. It must match the IP ADDRESS field on the NETWORK SETUP screen on
the DX3100.
•
•
•
User ID: Enter dx3100 (case-sensitive).
Password: Enter the password from the PASSWORD field on the NETWORK SETUP screen on the DX3100.
Camera: Specify the cameras to display.
d. Click OK.
ᕤ
Select Live or Remote Playback on the Site/File Open screen. Then click OK. The site video (live or playback) begins to display.
Operation
ᕡ
Launch the Remote Site Software:
Start > Program > DX3100RX > DX3100RX v1.0.
ᕢ
ᕣ
ᕤ
ᕥ
Click OK on the Input password screen. You can add a password later.
Click CONNECT. The Site/File Open screen appears.
Select the DX3100 to view.
Select Live or Remote Playback on the Site/File Open screen. Then click OK. The site video (live or playback) begins to display.
NOTE: To reconnect automatically when a network error occurs, select Try Reconnecting Continuously for Network or Server Error on the
Network Setup screen.
Pelco, the Pelco logo, Spectra, and Esprit are registered trademarks of Pelco in the United States and other countries.
Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
© Copyright 2003, Pelco. All rights reserved.
C695M-QS (12/03)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
World Headquarters
3500 Pelco Way
Clovis, California 93612 USA
USA & Canada
Tel: 800/289-9100
Fax: 800/289-9150
International
Tel: 1-559/292-1981
Fax: 1-559/348-1120
ISO9001
Orangeburg, New York Las Vegas, Nevada Eindhoven, The Netherlands Wokingham, United Kingdom Montreal, Canada
Singapore
Download from Www.Somanuals.com. All Manuals Search And Download.
|