Installation and Assembly:
Projector Ceiling/Wall Mount
Model#
Max UL Load Capacity
EXA, EXA-S, EXA-W, EXB, EXB-S,
EXB-W, EXC, EXC-S, EXC-W
used with PRS projector mount
used with PRG projector mount
25 lb (11.3 kg)
50 lb (22.7 kg)
This product is intended for use with UL
Listed products and must be installed by a
qualified professional installer.
R
Installed to
Ceiling
Installed to Wall
(EXC models are not wall mountable
due to its extensive reach)
Shown with PRG
projector mount and
projector (not included)
Features:
• For use with PRG-UNV and PRS-UNV Projector Mounts
• EXA and EXB series for ceiling or wall mounting
• EXC models for ceiling mounting
Shown with PRS
projector mount and
projector (not included)
• Integrated cable management
• Various height adjustments for ideal viewing positions
ISSUED: 1-11-08 SHEET #: 055-9495-2 10-16-08
1 of 11
3215 W. North Ave. • Melrose Park, IL 60160 • (800) 865-2112 or (708) 865-8870 • Fax: (708) 865-2941 • www.peerlessmounts.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Before you begin, make sure all parts shown are included with your product.
EXA,
EXB
Qty. Part #
EXA-S,
EXB-S
Part #
EXA-W,
EXB-W
Part #
Parts List
EXC
Part #
EXC-S
Part #
EXC-W
Part #
Description
A
B
C
D
E
F
ceiling plate
1
1
1
1
1
1
2
2
2
2
4
4
2
6
1
2
055-1773
055-4773
055-2773
055-1773
055-4773
055-2773
outer channel
SEE CHART
SEE CHART
055-1771
SEE CHART
SEE CHART
055-4771
SEE CHART
SEE CHART
055-2771
SEE CHART SEE CHART SEE CHART
SEE CHART SEE CHART SEE CHART
inner channel
clamp plate
055-1771
055-1876
N/A
055-4771
055-4876
N/A
055-2771
055-2876
N/A
vertical mounting plate
horizontal mounting plate
M5 x 16 mm socket pin screw
#14 x 2.5 wood screw
Alligator® concrete anchor
M6 x 12 mm socket pin screw
M6 x 10 mm socket pin screw
M5 x 10 mm socket pin screw
serrated locknut
055-1876
055-4876
055-2876
055-1787
055-4787
055-2787
G
H
J
520-1161
520-2161
520-2161
520-1161
520-2161
520-2161
5S1-015-C03 5S1-015-C04 5S1-015-C04 5S1-015-C03 5S1-015-C04 5S1-015-C04
590-0097
520-1050
520-1066
520-1063
530-1027
540-1078
560-9646
SEE CHART
590-0097
520-2050
520-2066
520-2063
530-2042
540-2078
560-9646
SEE CHART
590-0097
520-2050
520-2066
520-2063
530-2042
540-2078
560-9646
SEE CHART
590-0097
520-1050
520-1066
520-1063
530-1027
540-1078
560-9646
590-0097
520-2050
520-2066
520-2063
530-2042
540-2078
560-9646
590-0097
520-2050
520-2066
520-2063
530-2042
540-2078
560-9646
K
L
M
N
O
P
Q
flat washer
4 mm security allen wrench
cable cover
SEE CHART SEE CHART SEE CHART
OUTER CHANNEL, INNER CHANNEL AND CABLE COVER
PART NUMBER CHART
extendable
outer channel (B) inner channel (C)
cable cover (Q)
part#
Model#
EXA
length
part#
part#
8.69" - 12.79"
8.69" - 12.79"
8.69" - 12.79"
12.69" - 20.69"
12.69" - 20.69"
12.69" - 20.69"
19.14" - 32.9"
19.14" - 32.9"
19.14" - 32.9"
055-1779
055-4779
055-2779
055-1776
055-4776
055-2776
055-1770
055-4770
055-2770
055-1778
055-4778
055-2778
055-1775
055-4775
055-2775
055-1769
055-4769
055-2769
055-1809-2
055-4809-2
055-2809-2
055-1809-1
055-4809-1
055-2809-1
055-1809
EXA-S
EXA-W
EXB
EXB-S
EXB-W
EXC
EXC-S
EXC-W
055-4809
055-2809
ISSUED: 1-11-08 SHEET #: 055-9495-2 10-16-08
3 of 11
For customer care call 1-800-865-2112 or 708-865-8870.
Download from Www.Somanuals.com. All Manuals Search And Download.
Part List Continued
Parts may appear slightly different than illustrated.
C
A
B
D
H
F
E
K
G
J
L
M
N
O
P
Q
Install Outer Channel to Ceiling Plate
Attach outer channel (B) to ceiling plate (A) using
four M6 x 10 mm socket pin screws (L) as shown.
1
L
Tighten screws with security wrench (P).
A
B
ISSUED: 1-11-08 SHEET #: 055-9495-2 10-16-08
For customer care call 1-800-865-2112 or 708-865-8870.
4 of 11
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation to Wood Joist Ceilings or Wood Stud Walls
WARNING
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
• Tighten wood screws so that ceiling/wall plate is firmly attached, but do not overtighten. Overtightening can damage
the screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud or joist. The use of an "edge to edge" stud
finder is highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs or joists.
Installers are responsible to provide hardware for other types of mounting situations (not UL approved).
NOTE: Wall installation with models EXC, EXC-S and EXC-W is not available.
2
Use a stud finder to locate the edges of the stud or joist. Use of an edge-to-edge stud finder is highly
recommended. Based on its edges, draw a vertical line down the stud's or joist’s center. Place ceiling/wall plate (A)
on wall or ceiling as a template, making sure that the two mounting slots are on the centerline.
For ceiling installation: Opening on outer channel (B) indicates front of mount. Use the correct mounting slots on
the ceiling/wall plate depending on ceiling joist orientation as shown in figure 2.1 and figure 2.2. Mounting slots on
ceiling plate allow for 45° (±22.5) of rotation before securing to joist.
For wall installation: Opening on outer channel (B) indicates top of mount.
Mark the center of the two mounting holes. Drill two 5/32" (4 mm) dia. holes 2-1/2" (65 mm) deep. Secure
ceiling/wall plate (A) to wood stud or joist using two #14 x 2-1/2" wood screws (H) and two flat washers (O)
as shown.
Skip to step 3
WALL INSTALLATION
(EXCEPT FOR EXC MODELS)
CEILING INSTALLATION
WOOD
JOIST
fig. 2.2
WOOD
STUD
fig. 2.1
fig. 2.3
OPENINGONOUTER
CHANNEL(B) INDICATES
TOP OF MOUNT
A
A
B
O
H
MOUNTING
SLOTSALLOW
FOR ROTATION
BEFORE
SECURINGTO
JOIST
O
H
A
O
B
B
H
OPENING ON OUTER CHANNEL (B)
INDICATES FRONTOF MOUNT
ISSUED: 1-11-08 SHEET #: 055-9495-2 10-16-08
5 of 11
For customer care call 1-800-865-2112 or 708-865-8870.
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation to Concrete Ceilings or Concrete/Cinder Block Walls
WARNING
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete
thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid
part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifications.
It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid
breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
NOTE: Wall installation with models EXC, EXC-S
and EXC-W is not available.
CEILING
INSTALLATION
2
Place ceiling/wall plate (A) on ceiling or wall as a
template. Note: Place ceiling/wall plate according
to position of opening in outer channel (B) as shown
in figure 2.4. or figure 2.5. Drill two 1/4" (6 mm) dia.
holes to a minimum depth of 2.5" (64 mm). Attach
fig. 2.4
CONCRETE
CEILING
J
A
ceiling/wall plate (A) using two concrete anchors (J),
two #14 x 2.5" wood screws (H) and two washers (O)
as shown in figure 2.6. Tighten wood screws (H) until
ceiling/wall plate (A) is firmly attached.
O
OPENINGONOUTER
CHANNEL(B) INDICATES
FRONT OF MOUNT
H
B
WARNING
• Tighten wood screws firmly, but do not overtighten.
Overtightening can damage the screws, greatly
reducing their holding power.
CINDER
BLOCK
WALL
WALL INSTALLATION
(EXCEPT FOR
EXC MODELS)
CONCRETE
WALL
fig. 2.5
• Never tighten in excess of 80 in • lb (9 N.M.).
OPENINGONOUTER
CHANNEL (B)
INDICATESTOPOF B
A J
WARNING
• Always attach concrete expansion anchors directly to
load-bearing concrete.
MOUNT
O
H
concrete
surface
fig.
2.6
1
• Never attach concrete expansion anchors to concrete
covered with plaster, drywall, or other finishing mate-
rial. If mounting to concrete surfaces covered with a
finishing surface is unavoidable, the finishing surface
must be counterbored as shown below. Be sure
concrete anchors do not pull away from concrete
when tightening screws. If plaster/drywall is thicker
than 5/8" (16 mm), custom fasteners must be sup-
plied by installer (not UL approved).
J
Drill holes and insert anchors (J).
2
A
H
J
O
Place plate (A) over anchors (J) and secure with washers (O)
and screws (H).
INCORRECT
CORRECT
3
A
concrete
concrete
A
plaster/
dry wall
plaster/
dry wall
Tighten all fasteners.
ISSUED: 1-11-08 SHEET #: 055-9495-2 10-16-08
6 of 11
For customer care call 1-800-865-2112 or 708-865-8870.
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing Inner Channel and Routing Cables
Note: Be certain holes on inner channel (C) face in the same direction of opening on outer channel (B).
3
Note: Cables must be removed from projector before routing through channels. If cables are not removable from
projector, routing through channels is not an option.
Guide projector cables into openings in channels then insert inner channel (C) into outer channel (B) as shown in
figure 3.1 or 3.3.
Position inner channel (C) to the desired extended position and secure using two M6 x 12 mm socket pin
screws (K) through clamp plate (D) and into inner channel (C) as shown in figure 3.2 or 3.4.
WALL INSTALLATION
(EXCEPT FOR EXC MODELS)
CEILING INSTALLATION
fig. 3.1
B
OPENING
fig. 3.3
fig. 3.2
HOLES
B
C
OPENING
HOLES
K
K
D
D
B
C
B
GUIDE
CABLES IN
CHANNELS
C
fig. 3.4
C
ISSUED: 1-11-08 SHEET #: 055-9495-2 10-16-08
For customer care call 1-800-865-2112 or 708-865-8870.
7 of 11
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing Projector Mount
Installing PRG projector mount with ceiling installation: Attach vertical mounting plate (E) to PRG projector
mount (not included) using two M5 x 16 mm socket pin screws (G), four flat washers (O) and two locknuts (N) as
shown in figure 4.1.
4
Installing PRG projector mount with wall installation: Position PRG projector mount (not included) to the
orientation shown in figure 4.2 and attach to horizontal mounting plate (F) using two M5 x 16 mm socket pin
screws (G), four flat washers (O) and two locknuts (N).
WALL INSTALLATION
CEILING INSTALLATION
G
O
E
(EXCEPT FOR EXC MODELS)
F
fig. 4.1
fig. 4.2
G
PRGPROJECTOR
MOUNT (NOT
INCLUDED)
O
PRGPROJECTOR
MOUNT (NOT
INCLUDED)
ARROW
INDICATES
FRONT OF
MOUNT
ARROW
INDICATES
FRONT OF
MOUNT
O
O
N
N
Installing PRS projector mount with wall installation: Position PRS projector mount (not included) to the
orientation shown in figure 4.3 and attach to horizontal mounting plate (F) using two M5 x 16 mm socket pin
screws (G), four flat washers (O) and two locknuts (N).
Installing PRS projector mount with ceiling installation: Attach vertical mounting plate (E) to PRS projector
mount (not included) using two M5 x 16 mm socket pin screws (G), four flat washers (O) and two locknuts (N) as
shown in figure 4.4.
Note: Placing washer (O) and nut (N) combination on inside of PRG or PRS projector mount (not included) first while
attaching mounting bracket (E or F) can make installation easier as shown in figure 4.5.
WALL INSTALLATION
CEILING INSTALLATION
G
O
G
O
(EXCEPT FOR EXC MODELS)
fig. 4.3
fig. 4.4
PRSPROJECTORMOUNT
(NOT INCLUDED)
PRSPROJECTORMOUNT
(NOT INCLUDED)
E
F
HOLEINDICATES
FRONT OF MOUNT
HOLEINDICATES
FRONT OF MOUNT
O
O
N
N
PLACE WASHER (O)AND
NUT(N) COMBINATION
FIRST
fig. 4.5
PRSPROJECTORMOUNT
(NOT INCLUDED)
N
O
ISSUED: 1-11-08 SHEET #: 055-9495-2 10-16-08
8 of 11
For customer care call 1-800-865-2112 or 708-865-8870.
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing Projector Mount (continued)
Ceiling installation: Insert vertical mounting plate (E) into inner channel (C) with projector mount in the correct
orientation shown in figure 5.1 or 5.2. Secure vertical mounting plate to inner channel using four socket pin
screws (M) as shown in figure 5.3.
5
CEILING INSTALLATION
fig. 5.2
fig. 5.3
fig. 5.1
C
C
E
E
C
E
PRGPROJECTOR
MOUNT (NOT
INCLUDED)
PRSPROJECTOR
MOUNT (NOT
INCLUDED)
M
ARROW
HOLE
INDICATES
FRONT OF
MOUNT
INDICATES
FRONT OF
MOUNT
Wall installation: Insert horizontal mounting plate (F) into inner channel (C) as shown in figure 5.4 or 5.5. Secure
horizontal mounting plate to inner channel using four socket pin screws (M) as shown in figure 5.6.
WALL INSTALLATION
fig. 5.6
(EXCEPT FOR EXC MODELS)
fig. 5.5
fig. 5.4
M
C
ARROW
HOLEINDICATES
FRONT OF MOUNT
INDICATES
FRONT OF
MOUNT
F
C
C
F
F
PRSPROJECTOR
MOUNT (NOT
INCLUDED)
PRGPROJECTOR
MOUNT (NOT
INCLUDED)
Installing Projector
Refer to instruction manual included with your projector
mount for installing projector.
6
NOTE: Refer to instruction manual included with your
projector mount for max load capacity of your projector
mount.
Shown with PRG
projector mount and
projector (not included)
ISSUED: 1-11-08 SHEET #: 055-9495-2 10-16-08
9 of 11
For customer care call 1-800-865-2112 or 708-865-8870.
Download from Www.Somanuals.com. All Manuals Search And Download.
Adjusting Mount Extension
While supporting the weight of the projector, loosen clamp plate screws half a turn and position projector to the
desired extended position. Retighten clamp plate screws securely.
7
WARNING
• On ceiling installations, clamp plate adjustment screws support weight of projector when fully tightened. Weight of the
projector will need to be supported if clamp plate screws are loosened.
WALL INSTALLATION
(EXCEPT FOR EXC MODELS)
CEILING INSTALLATION
CLAMPPLATE
SCREWS
D
CLAMPPLATE
SCREWS
D
Install Cable Covers
Cut cable covers (Q) to the length of inner channel (C) and outer channel (B) openings, leaving space for cables if
routed through channels. Snap cable covers (Q) into openings as shown.
8
CEILING INSTALLATION
WALL INSTALLATION
(EXCEPT FOR EXC MODELS)
Q
CUT TO
LENGTH OF
OPENING
B
C
Q
CUT TO
LENGTH OF
OPENING
Q
B
CUT TO
Q
LENGTH OF
LENGTH OF
OPENING
C
CUT TO
OPENING
CABLES
CABLES
ISSUED: 1-11-08 SHEET #: 055-9495-2 10-16-08
10 of 11
For customer care call 1-800-865-2112 or 708-865-8870.
Download from Www.Somanuals.com. All Manuals Search And Download.
Projector Alignment
For PRG swivel adjustment: Loosen two screws indicated in figure 9.1 half a turn using allen wrench (P) to allow
for adjusting swivel. Align projector to the desired swivel position and fully tighten screws indicated.
9
For PRS swivel adjustment: Loosen two screws indicated in figure 9.1 half a turn using allen wrench (P) to allow
for adjusting swivel. Align projector to the desired swivel position and fully tighten screws indicated.
To adjust tilt and roll, refer to instruction included with projector mount.
WARNING
• Do not loosen adjustment screws to the point they become disengaged from the mount. Weight of the projector should
be supported in case of accidental disengagement.
fig. 9.2
fig. 9.1
SWIVEL ADJUSTMENT WITH PRG
SWIVEL ADJUSTMENT WITH PRS
SCREWS FOR SWIVEL
ADJUSTMENT
SCREWS FOR SWIVEL
ADJUSTMENT
20° (±10°) SWIVEL
SWIVEL ADJUSTMENT
TOP VIEW
ISSUED: 1-11-08 SHEET #: 055-9495-2 10-16-08
11 of 11
For customer care call 1-800-865-2112 or 708-865-8870.
©2008, PeerlessIndustries, Inc. Allrightsreserved.
Allotherbrandandproductnamesaretrademarksorregisteredtrademarksoftheirrespectiveowners.
Download from Www.Somanuals.com. All Manuals Search And Download.
|