Peerless Industries Flat Panel Television SF 16D User Manual |
Installation and Assembly:
Dedicated Flat Wall Mount for Flat Panel Screens
Models: SF 16D
Features:
• Ultra-slim design holds the screen flat against the wall
• Integrated security features provide effective theft deterrence
Max. Load Capacity: 200 lb (90.7 kg)
3215 W. North Ave. • Melrose Park, IL 60160 • (800) 729-0307 or (708) 865-8870 • Fax: (708) 865-2941 • www.peerlessmounts.com
ISSUED: 08-02-05 SHEET #: 202-9010-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts List
Description
Qty. Part #
wall plate
interface plate
#14 x 2.5" wood screw
Alligator® anchor
M10 x 1.5 x 15 mm socket head screw
4 mm security allen wrench
1
1
4
4
4
1
200-1797
AA
BB
CC
DD
EE
FF
200-0860
5S1-015-C03
590-0097
520-9262
560-1146
AA
BB
EE
DD
CC
FF
ISSUED: 08-02-05 SHEET #: 202-9010-1
3 of 9
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation to Single Wood Stud Wall
WARNING
• Installer must verify that the supporting surface will safely support the combined weight of all attached equipment and
hardware.
Use a stud finder to locate the edges of the stud. Use of an edge-to-edge stud finder is highly recommended. Based
on its edges, draw a vertical line down the stud’s center. Place wall plate (AA) on wall as a template, making sure
that the three mounting holes are over the stud centerline. The top mounting hole should be 2.5" above the desired
screen center as shown in figure 1.1. Level plate, and mark the center of the three holes. Drill three 5/32" (4 mm) dia.
holes 2-1/2" (65 mm) deep. Make sure that the wall plate is level, secure it using three #14 x 2.5" wood screws (CC)
as shown in figure 1.2.
1
Skip to step 2 on page 7.
WARNING
• Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder is
highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Installers
are responsible to provide hardware for other types of mounting situations.
AA
CS = center of screen
2.5"
(64 mm)
CS
fig. 1.1
CC
fig. 1.2
ISSUED: 08-02-05 SHEET #: 202-9010-1
4 of 9
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation to Double Wood Stud Wall
WARNING
• Installer must verify that the supporting surface will safely support the combined weight of all attached equipment and
hardware.
Wall plate (AA) can be mounted to two studs that are 16" apart. Use a stud finder to locate the edges of the studs.
Use of an edge-to-edge stud finder is highly recommended. Based on their edges, draw a vertical line down each
stud’s center. Place wall plate on wall as a template. The top mounting slots should be 2.5" above the desired
screen center as shown in figure 1.3. Level plate, and mark the center of the four mounting holes. Make sure that the
mounting holes are on the stud centerlines. Drill four 5/32" (4 mm) dia. holes 2-1/2" (65 mm) deep. Make sure that
the wall plate is level, secure it using four #14 x 2.5" wood screws (CC) as shown in figure 1.4.
1
Skip to step 2 on page 7.
WARNING
• Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder is
highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Install-
ers are responsible to provide hardware for other types of mounting situations.
CS = center of screen
AA
2.5"
(64 mm)
CC
CS
fig. 1.3
fig. 1.4
ISSUED: 08-02-05 SHEET #: 202-9010-1
5 of 9
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation to Solid Concrete or Cinder Block
WARNING
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete
thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid
part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifica-
tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to
avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard-
ware and components.
Make sure that wall plate (AA) is level, use it as a
concrete
surface
1
template to mark four mounting holes. The top
mounting hole should be 2.5" above the desired
screen center as shown in figure 1.1 on page 4. Drill
four 1/4" (6 mm) dia. holes to a minimum depth of
2.5" (64 mm). Insert anchors (DD) in holes flush with
wall as shown (right). Place wall plate over anchors
and secure with #14 x 2.5" screws (CC). Level, then
tighten all fasteners.
1
DD
Drill holes and insert anchors (DD).
2
AA
CC
WARNING
• Tighten screws so that wall plate is firmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
DD
Place plate (AA) over anchors (DD) and secure with screws (CC).
• Never tighten in excess of 80 in. • lb (9 N.M.).
3
WARNING
• Always attach concrete expansion anchors directly to
load-bearing concrete.
Tighten all fasteners.
• Never attach concrete expansion anchors to concrete
covered with plaster, drywall, or other finishing mate-
rial. If mounting to concrete surfaces covered with a
finishing surface is unavoidable, the finishing surface
must be counterbored as shown below. Be sure
concrete anchors do not pull away from concrete
when tightening screws. If plaster/drywall is thicker
than 5/8", custom fasteners must be supplied by
installer.
DD
AA
CC
CORRECT
INCORRECT
wall plate
concrete
concrete
wall
plate
plaster/
drywall
plaster/
drywall
ISSUED: 08-02-05 SHEET #: 202-9010-1
6 of 9
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing Interface Bracket to PLP Adapter Plate
To prevent scratching the screen, set a cloth on a flat, level surface that will support the weight of the screen. Place
screen face side down. Attach the interface bracket (BB) to the PLP adapter plate (sold separately) using four M10 x
15 mm socket head screws (EE) as shown in figures 2.1 (portrait) or 2.2 (landscape).
2
WARNING
• Tighten screws so adapter brackets are firmly attached. Do not tighten with excessive force. Overtightening can cause
stress damage to screws, greatly reducing their holding power and possibly causing screw heads to become
detached. Tighten to 40 in. • lb (4.5 N.M.) maximum torque.
GENERICPLP
ADAPTER PLATE
GENERICPLP
ADAPTER PLATE
BB
EE
EE
BB
fig. 2.2
(landscape)
fig. 2.1
(portrait)
ISSUED: 08-02-05 SHEET #: 202-9010-1
7 of 9
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing Interface Bracket to LC Adapter Plate
To prevent scratching the screen, set a cloth on a flat, level surface that will support the weight of the screen. Place
screen face side down. Attach the interface bracket (BB) to the LC adapter plate (sold separately) using four M5
screws provided with plate as shown in figures 2.3 (portrait) or 2.4 (landscape).
2
WARNING
• Tighten screws so adapter brackets are firmly attached. Do not tighten with excessive force. Overtightening can cause
stress damage to screws, greatly reducing their holding power and possibly causing screw heads to become
detached. Tighten to 40 in. • lb (4.5 N.M.) maximum torque.
GENERICLC
ADAPTER PLATE
GENERICLC
ADAPTER PLATE
BB
BB
M5 SCREWS
M5 SCREWS
fig. 2.4
(landscape)
fig. 2.3
(portrait)
ISSUED: 08-02-05 SHEET #: 202-9010-1
8 of 9
Download from Www.Somanuals.com. All Manuals Search And Download.
Mounting and Removing Flat Panel Screen
Note: Security screw may need to be loosened to avoid interference with wall plate.
3
Hook interface bracket (BB) onto wall plate (AA). Then slowly swing screen in as shown. Turn security screw, using
security allen wrench (FF), clockwise at least six times to prevent screen from being removed as shown in detail 1.
Screen can be adjusted horizontally if desired.
Note: To lock the screen down, tighten security screw to wall plate using security allen wrench as shown in detail 1.
To remove screen from mount, loosen security screw, swing screen away from mount, and lift screen off of mount.
WARNING
• Always use an assistant or mechanical lifting equipment to safely lift and position the plasma television.
BB
AA
SECURITY
SCREW
BB
DETAIL 1
ISSUED: 08-02-05 SHEET #: 202-9010-1
©2005PeerlessIndustries,Inc.Allrightsreserved.
SmartMountisatrademarkandPeerlessisaregisteredtrademarkofPeerlessIndustries,Inc.
Allotherbrandandproductnamesaretrademarksorregisteredtrademarksoftheirrespectiveowners.
9 of 9
Download from Www.Somanuals.com. All Manuals Search And Download.
|