TURBOPOWER® GAS/OIL PACKAGED WATER HEATER  
NICKELSHIELD® NICKEL-PLATED STORAGE TANK  
TANK SERIES 600 GALLONS  
Blower  
Motor  
Recovery gph ꢀ  
Dimensions (inches)  
Min. Inlet Flow  
Gas Pressure  
"W.C. ꢂ  
Shipping  
Weight  
lbs  
Model  
Number  
Input  
Btu/h  
#2 Oil  
gph  
Volt/Ph/  
Amps  
40°- 120°F 40°- 140°F  
A
B
C
J ꢁ  
HP  
750 N 600A-TPGO  
1000 N 600A-TPGO  
1250 N 600A-TPGO  
1500 N 600A-TPGO  
2000 N 600A-TPGO  
2500 N 600A-TPGO  
750  
1000  
1250  
1500  
2000  
2500  
600  
800  
600,000  
800,000  
4.5  
6.0  
7.5  
7.5  
6.5  
8.0  
4.3  
5.7  
46  
46  
54  
54  
63  
65  
6
8
1
31  
31  
31  
31  
36  
36  
1/2  
1/2  
3/4  
1
2720  
2760  
2850  
2930  
3140  
3260  
115/1/10  
115/1/10  
115/1/14  
115/1/16  
115/1/24  
115/1/24  
1
1
1000  
1200  
1600  
2000  
1,000,000  
1,200,000  
1,600,000  
2,000,000  
7.2  
8
8.6  
8
1-1/4  
2
11.4  
14.3  
10  
10  
2
2
2
Recoveries based on 83% thermal efficiency. ASHRAE 90.1 compliant for efficiency and standby loss.  
"J" dimension is for the burner housing only. Gas train may exceed this dimension.  
Standard gas train.  
*
The information presented is for Natural gas 0.6 S.G.— For operation with propane (LP gas), consult factory.  
Dimensions are in inches unless otherwise specified.  
Higher inputs available. Consult the factory.  
For standard and optional equipment, see form PV 6046.  
* REAR ACCESS MODULE  
* GAS PRESSURE REQUIREMENTS  
MODEL PREFIX  
750-1500  
M
L
STD or OPTIONAL  
OPTIONAL  
SEE TABLE FOR MINIMUM PRESSURE BY MODEL NUMBER.  
MAXIMUM STATIC INLET PRESSURE: 14" W.C.  
23"  
23"  
8"  
FOR PRESSURES OTHER THAN LISTED, CONSULT FACTORY.  
2000-2500  
16"  
STANDARD  
Pressure shown is for standard UL gas train. Additional controls  
may increase pressure requirements.  
STANDARD ELECTRICAL REQUIREMENTS  
VENTING REQUIREMENTS  
CONTROL VOLTAGE: 120V, 1Ø, 60 HZ., 2 AMPS.  
MOTOR VOLTAGE:  
-.02" TO -.06" W.C. (NEGATIVE PRESSURE)  
208V, 230V, AND 460V MOTORS ARE AVAILABLE BUT WILL  
REQUIRE A SEPARATE 120V/2 amps CONTROL CIRCUIT OR AN  
OPTIONAL CONTROL CIRCUIT TRANSFORMER.  
ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED  
UPON THE VENT CONNECTION DIAMETER EXCLUSIVELY.  
FOR PROPER SIZING, CONSULT  
THE NATIONAL FUEL GAS CODE UNDER “FAN-ASSISTED.”  
PVI RESERVES THE RIGHT TO CHANGE THE DESIGN  
AND SPECIFICATION WITHOUT NOTICE.  
PVI INDUSTRIES, LLC  
FORT WORTH, TEXAS 76111  
(800) 784-8326 (817) 335-9531 www.pvi.com  
Product is patented in the U.S., Canada, and Mexico.  
PV 5460 03/04  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Peavey Music Mixer 3014 User Manual
Pelco Home Security System C491M D User Manual
Petsafe Pet Fence Cottageview Dog Kennel User Manual
Philips CRT Television 13PR19C User Manual
Philips Electric Shaver 6709X User Manual
Philips Flat Panel Television TH 50PH10UKA User Manual
Philips Laptop SA2200 User Manual
Philips VCR VR205 User Manual
Philips Work Light CD7 2 User Manual
ProForm Home Gym PFEL51053 User Manual