OnSite™ Model 3088A Series
G.SHDSL.bis CPE with Fixed
Serial Interfaces
Quick Start Guide
Important—This is a Class A device and is intended for use in a light industrial environment. It is not
intended nor approved for use in an industrial or residential environment.
REGULATORY MODEL NUMBER: 03340D4-001
Sales Office: +1 (301) 975-1000
Technical Support: +1 (301) 975-1007
Part Number: 07M3088A-QS, Rev. A
Revised: February 2, 2012
E-mail: [email protected]
Download from Www.Somanuals.com. All Manuals Search And Download.
1.0 Select configuration method
Before powering up, you must select one of the following methods for configuring your OnSite:
•
Plug ‘n’ Play—The OnSite comes factory-configured for Plug ’n’ Play configuration when connected to a
service-provider network.
•
DIP Switch—For deploying the OnSite in back-to-back applications. To use DIP-switch configuration you
must first set the DIP switches to a position other than all OFF or all ON before powering-up the OnSite. To
configure your CPE using the DIP switches, refer to the section entitled “Hardware (DIP-switch) configuration”
in the OnSite Model 3088A Series Getting Started Guide.
•
Software Configuration—Allows you to modify configurable parameters by connecting a PC to the con-
sole port and issuing software commands. To use software configuration you must set all the DIP switches to
the ON position before powering-up the OnSite. To configure your CPE via the console port, refer to section
“Software (CLI) configuration” in the OnSite Model 3088A Series Getting Started Guide.
2.0 Power up the CPE
Your G.SHDSL.bis CPE comes with one of the following power supply options:
•
External AC adaptor with detachable power cord
•
External DC power supply with terminal block connector (model 48V-PSM3)
2.1 Models with external AC adaptor
1. Connect female plug of the AC power cord to the AC adaptor provided.
2. Connect the barrel-type connector of the AC adaptor to the Power connector on the OnSite.
3. Insert the male plug of the AC power cord into an AC power outlet (100–240 VAC).
2.2 Models with external DC power supply
The 36-60 VDC DC to DC adapter is supplied with the DC version of the Model 3088A. The black and red leads
plug into a DC source (nominal 48VDC) and the barrel power connector plugs into the barrel power supply jack
on the 3088A. (See figure 1).
To Power
To -48VDC
Supply Jack
Source
-Vin
Black lead (-V)
Red lead (+V)
+Vin
Barrel power connector
Figure 1. DC Power Supply
Model 3088A Series Quick Start Guide
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Link
Activity
TM / ERR
Terminal
DSL
Power
Figure 2. Model 3088A/CA front panel
2.3 Power up indication
Verify that the Power LED (see figure 2) illuminates and remains lit.
3.0 Connect the G.SHDSL port
1. Obtain single-twisted-pair cable with an RJ-45 plug connector at each end.
2. Plug one end of the cable into the RJ-45 socket (labelled DSL) on the OnSite CPE.
— If you are connecting to a DSL service, plug the other end of the cable into the RJ-45 wall
socket that provides your G.SHDSL service.
— If connecting to another OnSite, verify the other end of the cable is connected to the DSL port
on other OnSite and the DSL port is correctly configured.
3. When a DSL link is established, the front-panel DSL LED will turn on.
4.0 Connect the serial port
Your OnSite comes with one of the following serial WAN ports for connection to an CPE:
•
•
•
•
RS-232 (DB-25F)—Model 3088A/A
V.35 (DB-25F)—Model 3088A/CA
X.21 (DB-15)—Model 3088A/D
E1 (120-Ohm RJ-48C and dual 75-Ohm BNC connectors)—Model 3088A/K
4
Model 3088A Series Quick Start Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Connect the serial cable to the OnSite serial port as follows:
1. Attach the male connector of the serial cable to the female serial connector on the OnSite.
2. Attach the other end of the cable to the serial connector on the local serial CPE.
Note You can connect the V.35 interface to an M/34 connector using Patton’s Model 2-34F25M
interface adapter.
Note You can configure the E1 interface to either recover the network clock from the E1 line or supply the
network clock for the E1 line.
5.0 Additional information
For detailed information about installing, configuring, operating, and troubleshooting, refer to the Model 3088A
A.0 Compliance Information
A.1 Compliance
EMC:
•
•
•
FCC Part 15, Class A
EN55022, Class A
EN55024
Safety:
•
UL 60950-1/CSA C22.2 N0. 60950-1
•
IEC/EN60950-1
•
AS/NZS 60950-1
1.2 Radio and TV Interference (FCC Part 15)
This equipment generates and uses radio frequency energy, and if not installed and used properly—that is, in
strict accordance with the manufacturer's instructions—may cause interference to radio and television recep-
tion. This equipment has been tested and found to comply with the limits for a Class A computing device in accor-
dance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable
protection from such interference in a commercial installation. However, there is no guarantee that interference
will not occur in a particular installation. If the equipment causes interference to radio or television reception,
which can be determined by disconnecting the cables, try to correct the interference by one or more of the fol-
lowing measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna,
and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and
receiver are on different branches).
Model 3088A Series Quick Start Guide
5
Download from Www.Somanuals.com. All Manuals Search And Download.
1.3 Industry Canada Notice
This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications. This is con-
firmed by the registration number. The abbreviation, IC, before the registration number signifies that registra-
tion was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications
were met. It does not imply that Industry Canada approved the equipment.
This Declaration of Conformity means that the equipment meets certain telecommunications network protective,
operational and safety requirements. The Department does not guarantee the equipment will operate to the
user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to
the facilities of the local telecommunications company. The equipment must also be installed using an acceptable
method of connection. In some cases, the company’s inside wiring associated with a single line individual service
may be extended by means of a certified connector assembly (telephone extension cord). The customer should
be aware that compliance with the above condition may not prevent degradation of service in some situations.
Repairs to some certified equipment should be made by an authorized maintenance facility designated by the
supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give
the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for
their own protection that the ground connections of the power utility, telephone lines and internal metallic water
pipe system, are connected together. This protection may be particularly important in rural areas.
A.4 EC Declaration of Conformity
(See section A.5 “EG-Konformitätserklärung” for German version.)
Product Description: OnSite 3088A Series
This equipment conforms to the requirements of Council Directive 1999/5/EC on the approximation of the laws
of the member states relating to Radio and Telecommunication Terminal Equipment and the mutual recognition
of their conformity.
The safety advice in the documentation accompanying the products shall be obeyed.
The conformity to the above directive is indicated by the CE sign on the device.
The signed Declaration of Conformity can be downloaded from www.patton.com/certifications/.
A.5 EG-Konformitätserklärung
(see section A.4 “EC Declaration of Conformity” for English version)
Produktbezeichnung: OnSite 3088A Sendereihe
Die bezeichneten Produkte stimmen in der von uns in Verkehr gebrachten Ausführung mit den Vorschriften fol-
gender Richtlinie überein:
R&TTE 1999/5/EG
Richtlinie des europäischen Parlaments und des Rates zur Angleichung der Rechtsvorschriften der
Mitgliedstaaten über Funkanlagen und Telekommunikations-Endeinrichtungen und die gegenseitige
Anerkennung ihrer Konformität.
6
Model 3088A Series Quick Start Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Die Sicherheitshinweise in der mitgelieferten Produktdokumentation sind zu beachten.
Die Konformität mit der oben erwähnten Richtlinie wird durch das CE-Zeichen auf dem
Gerät bestätigt.
Die unterzeichnete Konformitätserklärung kann heruntergeladen werden von: www.patton.com/
certifications/.
A.6 Authorized European Representative
D R M Green
European Compliance Services Limited.
Oakdene House, Oak Road
Watchfield,
Swindon, Wilts SN6 8TD, UK
Copyright statement
Copyright © 2012, Patton Electronics Company. All rights reserved.
The information in this document is subject to change without notice. Patton Electronics assumes no
liability for errors that may appear in this document.
Trademarks statement
The term OnSite is a trademark of Patton Electronics Company. All other trademarks presented in this document
are the property of their respective owners.
Patton support headquarters in the USA
•
•
•
Online support: Available at www.patton.com
Telephone support: Standard telephone support is available five days a week—from 8:00 am to
5:00 pm EST (1300 to 2200 UTC/GMT)—by calling +1 (301) 975-1007
•
•
Support via VoIP: Contact Patton free of charge by using a VoIP ISP phone to call sip:[email protected]
Fax: +1 (253) 663-5693
Alternate Patton support for Europe, Middle East, and Africa (EMEA)
•
Telephone support: Standard telephone support is available five days a week—from 8:00 am to
5:00 pm CET (0900 to 1800 UTC/GMT)—by calling +41 (0)31 985 25 55
•
Fax: +41 (0)31 985 25 26
Note For additional service and support information, refer to the “Contacting Patton for assistance” chapter
3088A.pdf.
Model 3088A Series Quick Start Guide
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Warranty, Trademark, & Compliance Information
For warranty, trademark and compliance information, refer to the OnSite 3088A Getting Started Guide available
8
Model 3088A Series Quick Start Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
|