TM
Hotwiret 5620 RTU Customer Premises
Installation Instructions
Document Number 5620-A2-GN10-30
December 1998
Before You Begin
The Hotwiret 5620 RTU (Remote Termination Unit) interoperates with the Hotwire
8510 DSL Card in the DSLAM (Digital Subscriber Line Access Multiplexer) system.
An optional POTS (Plain Old Telephone Service) splitter is available for the Hotwire
5620 RTU. When a POTS splitter is installed, the telephone and 5620 RADSL (Rate
Adaptive Digital Subscriber Line) RTU can function at the same time over the same pair
of copper wires. In order to confirm the RTU installation, the POTS splitter should be
installed first.
To install a POTS splitter, refer to the appropriate POTS splitter document:
Document Number Document Title
5030-A2-GN10
Hotwire 5030 POTS Splitter Customer Premises
Installation Instructions
5038-A2-GN10
Hotwire 5038 Distributed POTS Splitter Customer
Premises Installation Instructions
Contact your sales or service representative to order additional product documentation.
Paradyne documents are also available on the World Wide Web at:
Select Service & Support → Technical Manuals
Wiring and Cables Needed
The following wiring and standard connectors are used with this product:
-
New or existing unshielded twisted-pair wiring (CAT3 or better). The CAT3 wiring
must meet EIA/TIA-568 specifications with 24 AWG (.5 mm) or 26 AWG (.4 mm).
-
Standard RJ11 wall jack.
-
Standard Ethernet 8-pin, non-keyed modular plug for a PC or workstation. An
Ethernet straight-through or crossover cable is used. Refer to Installing the Hotwire
5620 RTU, page 8, for Ethernet cable details.
Download from Www.Somanuals.com. All Manuals Search And Download.
1
Customer Premises (CP)
Demarcation
Point
CP
POTS
POTS
Splitter
End-user
Systems
Central
Office
(CO)
DSL
Jack
RTU
DSL
Local Loop
Network
Service
Provider
(NSP)
Ethernet
Crossover or
Cable
Ethernet
Cable
Punchdown
Block or NID
Hub or
Router
98-16105
DSL – Digital Subscriber Line
NID – Network Interface Device
POTS – Plain Old Telephone Service
RTU – Remote Termination Unit
New Wiring Connections
Existing Wiring (POTS)
DSL Access with a Hotwire 5038 Distributed POTS Splitter
When a Hotwire 5038 Distributed POTS Splitter is used, one 5038 Distributed POTS
Splitter is installed as a filter for each telephone on the same POTS line as DSL.
Customer Premises (CP)
Demarcation
Point
Optional
To End-user
Systems
POTS
Central
Office
(CO)
RTU
Splitter
POTS/DSL
POTS
Splitter
Local Loop
Network
Service
Provider
(NSP)
POTS
Splitter
Punchdown
Block or NID
98-15815-01
DSL – Digital Subscriber Line
NID – Network Interface Device
POTS – Plain Old Telephone Service
RTU – Remote Termination Unit
Download from Www.Somanuals.com. All Manuals Search And Download.
3
DSL Access without a POTS Splitter
When the Hotwire 5620 RTU is installed without a POTS splitter, a second telephone
wiring pair is needed for DSL access.
Customer Premises (CP)
Demarcation
Point
POTS
Central
Office
(CO)
End-user
Systems
DSL
Jack
RTU
DSL
Local Loop
Ethernet
Crossover or
Cable
Network
Service
Provider
(NSP)
Ethernet
Cable
Punchdown
Block or NID
Hub
97-15345-02
DSL – Digital Subscriber Line
NID – Network Interface Device
POTS – Plain Old Telephone Service
RTU – Remote Termination Unit
New Wiring Connections
Existing Wiring (POTS)
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Installing the DSL Access Wiring
The local loop terminates at the punchdown block or NID. Wiring must be connected
from the customer premises side of the punchdown block or the NID to the DSL jack.
Typically, the punchdown block is installed in commercial locations and the NID is
installed in residential locations.
" Procedure
1. Access the punchdown block or NID.
!
WARNING:
Do not continue unless the DSL access line from the local loop has been
disconnected at the NID or punchdown block. Refer to Important Safety
Instructions, page 17.
2. Disconnect the DSL access pair from the local loop. A punchdown block is used
without a POTS splitter in the following example.
Punchdown Block
Customer Premises
Wiring to
DSL Jack
Demarcation Point
Bridge Clip
DSL
Access
from Local
Loop
A
B
C
D
97-15348
Download from Www.Somanuals.com. All Manuals Search And Download.
5
3. Locate the DSL pair of T1/R1 connectors on the customer premises side of the
NID or punchdown block. Attach the wiring that will be connected to the DSL jack.
In the following example, a NID is used without a POTS splitter. It includes an
existing POTS line and a second pair installed for DSL access.
Telephone Network Interface Device (NID)
Customer Premises
Demarcation Point
Tip
T1
(Green)
DSL Pair
POTS Pair
Ring
R1
(Red)
Wiring to
DSL Jack
DSL/POTS
Access from
Local Loop
Existing POTS
Wiring to
Telephone
Ground
97-15438-01
Download from Www.Somanuals.com. All Manuals Search And Download.
6
The Hotwire 5620 RTU connects to the local loop via wiring from the demarcation point
to an RJ11 wall jack. The DSL twisted-pair wiring from the local loop terminates at a
new or existing wall jack. It may be necessary to install a standard single RJ11 jack or
replace a single jack with a double RJ11 wall jack.
Customer Premises
Demarcation Point
DSL
Twisted-pair
Wiring
DSL
RJ11
Jack
Central
Office
POTS/DSL
Local Loop
RTU
Punchdown
Block or NID
97-15343-02
" Procedure
1. Wiring can be run from the
punchdown block or NID to a
new or existing wall jack. Match
the pair colors on both ends.
RJ11 Wall Jack
2. Label the DSL jack.
or
3. Reconnect the DSL access pair
at the punchdown block or NID.
Refer to Installing the DSL
Access Wiring, page 5. Tighten
both terminal screws with a flat-
blade screwdriver.
97-15300a
The RJ11 6-pin jack uses the center two pins. For pin assignments, refer to Cables &
Connectors, page 15.
Download from Www.Somanuals.com. All Manuals Search And Download.
7
Installing the Hotwire 5620 RTU
Place the Hotwire 5620 RTU on a flat surface with clearance for the rear connectors.
" Procedure
1. Use the supplied RJ11 6-pin interface cable for the DSL connection. Insert one end
of the cable into the jack labeled DSL. Insert the other end into the wall jack
labeled DSL.
Hotwire RTU
POWER
ETHERNET
DSL
DSL
Jack
97-15300-01
If the Hotwire 5620 RTU is installed on the same line as POTS, a Hotwire 5038
Distributed POTS Splitter can be used as a filter. One Hotwire 5038 Distributed
POTS splitter is installed as a filter for each telephone, as shown below. To install
the Hotwire 5038 Distributed POTS splitter, refer to Hotwire 5038 Distributed
POTS Splitter Customer Premises Installation Instructions.
Customer
Premises (CP)
Hotwire
RTU
Distributed
POTS Splitter
Distributed
POTS Splitter
Line from
RJ11 Wall Jack
Line from
RJ11 Wall Jack
Distributed
POTS Splitter
98-15813
Download from Www.Somanuals.com. All Manuals Search And Download.
8
2. Use an 8-pin Ethernet cable for the Ethernet connection. Insert one end of the
cable into the jack labeled ETHERNET.
H
Use a straight-through cable and connect the other end to an Ethernet hub, or
Hotwire RTU
Ethernet
Line
PO
WER
EERNET
DSL
Ethernet
Ethernet
Cable
Hub
97-15303-01
H
Use an Ethernet crossover cable and connect the other end to a PC with an
Ethernet Network Interface Card (NIC) installed.
Hotwire RTU
Ethernet
Line
PO
WER
EERNET
PC with Ethernet
DSL
Network Interface
Card
Ethernet
Cable
97-15303b
For RTU cable pin assignments, refer to Cables & Connectors, page 15.
Download from Www.Somanuals.com. All Manuals Search And Download.
9
3. Place the large ferrite choke on the
Ethernet cable as closely as possible to
the RTU. Pass the Ethernet cable through
the ferrite choke twice, creating a loop as
shown.
496-14952
Hotwire RTU
4. Close the two halves
around the cable and
snap the ferrite choke
shut. Press down on the
plastic latch to secure
the ferrite choke in place
around the cable.
Ethernet
Line
PO
WER
EERNET
DSL
Ferrite
Choke
97-15303c
5. Insert the power cord’s round end into the jack labeled POWER. Attach the ferrite
choke on the power cord as closely as possible to the RTU. Pass the power cable
through the ferrite choke twice, creating a loop as shown.
Hotwire RTU
Power
Jack
PO
WER
EERNET
Ferrite
Choke
DSL
or
97-15796
6. Close the two halves around the cable and snap the ferrite choke shut. Press
down on the plastic latch to secure the ferrite choke in place around the cable.
7. Plug the transformer into an AC outlet. The RTU hardware installation is now
complete. When the power cord is installed, the RTU goes through a power-on
self-test.
Download from Www.Somanuals.com. All Manuals Search And Download.
10
Optional RTU Wall Placement
The Hotwire 5620 RTU is designed for tabletop placement. The RTU can also be
mounted on a wall. To mount an RTU, you will need:
-
Three slotted-head #6 self-threading screws with molly bolts
-
Drill and 3/16I drill bit for the molly bolts
-
Screwdriver
A template with the dimensions for the three screws is provided. See RTU Hardware
Template on page 12.
" Procedure
To mount the RTU:
1. Use a drill to install the plastic anchors (molly bolts).
2. Use a screwdriver to install the screws. Do not install the screws flush with the
wall. Leave enough clearance to hang the RTU housing from the screws.
Wall
Fasteners
Hotwire
RTU
98-16170
Download from Www.Somanuals.com. All Manuals Search And Download.
11
RTU Hardware Template
5.43"
Front
(LEDs)
7.55"
To Bottom
Hole
98-16171
Download from Www.Somanuals.com. All Manuals Search And Download.
12
Power-On
When power is applied, the RTU performs self-diagnostics and the PWR LED is on.
The self-diagnostics includes a power-on self-test. During the power-on self-test, all of
the LEDs turn on for one second.
Power – green
Alarm – red
Test – yellow
Digital Subscriber Line – green
Ethernet Link – green
PWR
ALM
TST
ETHERNET
DSL
5620
TM
98-15835
Refer to Troubleshooting, page 14, for LED indications requiring action.
Status LEDs
All of the LEDs turn on and off during the power-on self-test. After a successful
self-test, the LEDs should appear as indicated in BOLD in the Condition column below.
LED
PWR
ALM
Condition Status
ON
RTU has power.
OFF
No active alarms.
ON
An alarm condition exists.
TST
DSL
OFF
No active tests.
ON
The TST LED is on during the power-on self-test and
during a test initiated by the NSP.
Blinking
ON
RTU is establishing the active DSL link. The LED blinks
on and off about five times per second.
The DSL link is now active and ready to transmit and
receive data.
OFF
The DSL link has not been established.
ETHERNET ON
The Ethernet 10BaseT connection to the Ethernet hub or
PC is active.
OFF
No Ethernet 10BaseT device is detected.
Download from Www.Somanuals.com. All Manuals Search And Download.
13
Troubleshooting
LED Symptom
Action
All LEDs are on.
The RTU may be in download mode. Wait ten minutes.
If LEDs remain on after ten minutes and the RTU is not in
download mode, the RTU is not functional. Contact the NSP.
ALM LED remains
on.
The power-on self-test may have failed. Unplug the unit and
reapply power. If the alarm LED is still on, contact the NSP.
ALM and TST
LEDs are on.
Firmware download may be in progress. If firmware download
is not in progress or the LEDs remain on after ten minutes,
contact the NSP.
DSL LED is off.
Verify that the DSL cable is securely installed on both ends. If
the problem continues, contact the NSP.
DSL LED continues The RTU is attempting to establish the DSL link or is adjusting
to blink after the
power-on self-test.
the rate of the DSL line due to line conditions. If the DSL LED
continues to blink for more than five minutes, contact the NSP.
DSL LED is on and The DSL link has been established but there is no data
there is no data
transmission.
transmission. Verify the Ethernet connection. If the problem
persists, contact the NSP.
DSL and Ethernet
LEDs are on and
there is no data
transmission.
The DSL and Ethernet links have been established but there is
no data transmission. If the problem continues, contact the
NSP.
Ethernet LED is off.
Verify that the Ethernet 10BaseT cable is securely installed at
both ends, and at least one PC is connected and powered on.
Verify that the correct straight-through or crossover cable is
installed. Refer to Installing the Hotwire 5620 RTU, page 8.
PWR LED is off.
Check that the power cord is securely installed on both ends.
If no LEDs are on, the power supply may be defective. Test the
outlet to verify power. If the problem persists, contact the NSP.
If other LEDs are on, the PWR LED may be burned out. Unplug
the unit and reapply power; watch all LEDs during the
power-on self-test to verify if the PWR LED is functioning.
TST LED is on.
A test initiated by the NSP may be active. Wait five minutes.
If the TST LED does not go off, contact the NSP.
Increasing the Number of End-User Systems
A single PC is attached to the Hotwire 5620 RTU using an Ethernet crossover cable. To
increase the number of PCs, connect all PCs to an Ethernet hub using a
straight-through cable. The Hotwire 5620 RTU can support up to 32 PCs. Verify any
planned changes with the NSP.
Download from Www.Somanuals.com. All Manuals Search And Download.
14
Cables & Connectors
Use standard twisted-pair CAT3 or better cables.
This section is reference information.
H
The Ethernet interface connector uses an 8-pin, non-keyed modular plug.
— To connect the RTU to an Ethernet hub, use the straight-through connection.
8-Pin Straight-Through Connection
Ethernet
Cable
Pin # Function
1
2
3
10BaseT TX D+
10BaseT TX D–
10BaseT RX D+
8-Pin
Plug
4 & 5 Not used
6
10BaseT RX D–
7 & 8 Not used
Pin #8
Pin #1
98-16055a
— To connect the RTU directly to a PC with an Ethernet NIC card, use an
Ethernet crossover cable.
8-Pin Ethernet Crossover Cable
Function Pin #
Pin # Function
10BaseT TX D+
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
10BaseT TX D+
10BaseT TX D–
10BaseT RX D+
Not Used
10BaseT TX D–
10BaseT RX D+
Not Used
Not Used
Not Used
10BaseT RX D–
Not Used
10BaseT RX D–
Not Used
Not Used
Not Used
97-15316
Download from Www.Somanuals.com. All Manuals Search And Download.
15
H
The DSL interface connector uses a 6-pin,
non-keyed modular plug.
DSL
Cable
RJ11 6-Pin Connector
6-Pin
RJ11 Plug
Pin # Function
1 & 2 Not used
Pin #6
Pin #1
3
4
DSL Ring
DSL Tip
5 & 6 Not used
98-15304-01
Model 5620 RTU Technical Specifications
*
Item
Specification
Height x Width x Depth
Weight
1.43″ x 6.00″ x 8.75″ (3.64 cm x 15.24 cm x 22.23 cm)
1 lb. 1 oz. (0.48 kg)
Power
Input:
100 Vac (+10%), 50 Hz;
120 Vac (+10%), 60 Hz; or
230 Vac (+10%), 50/60 Hz
Class 2 Transformer normal
service input voltage range
Output:
15 Vdc nominal, minimum 0.6A
Approvals
FCC Part 15
CISPR 22
Class B Subpart B digital device
Class B
Safety Certifications
Refer to equipment’s label for approvals on product
Physical Environment
Operating temperature
Storage temperature
Relative humidity
32°F to 104°F (0°C to 40°C)
–4°F to 158°F (–20°C to 70°C)
5% to 95% (noncondensing)
Shock and vibration
Withstands normal shipping and handling
Heat Dissipation
33.8 Btu/hr. (max.) at nominal input voltage
Interface Connectors
DSL Interface
Ethernet Type II Frame
*
RJ11 6-pin
10BaseT 8-pin
Technical Specifications subject to change without notification.
Download from Www.Somanuals.com. All Manuals Search And Download.
16
Important Safety Instructions
1. Read and follow all warning notices and instructions marked on the product or
included in the manual.
2. Slots and openings in the cabinet are provided for ventilation. To ensure reliable
operation of the product and to protect it from overheating, these slots and
openings must not be blocked or covered.
3. Do not allow anything to rest on the power cord and do not locate the product
where persons will walk on the power cord.
4. Do not attempt to service this product yourself, as opening or removing covers
may expose you to dangerous high voltage points or other risks. Refer all servicing
to qualified service personnel.
5. General purpose cables are used with this product for connection to the network.
Special cables, which may be required by the regulatory inspection authority for
the installation site, are the responsibility of the customer. Use a UL Listed, CSA
certified, minimum No. 24 AWG line cord for connection to the Digital Subscriber
Line (DSL) network.
6. When installed in the final configuration, the product must comply with the
applicable Safety Standards and regulatory requirements of the country in which it
is installed. If necessary, consult with the appropriate regulatory agencies and
inspection authorities to ensure compliance.
7. A rare phenomenon can create a voltage potential between the earth grounds of
two or more buildings. If products installed in separate buildings are
interconnected, the voltage potential may cause a hazardous condition. Consult a
qualified electrical consultant to determine whether or not this phenomenon exists
and, if necessary, implement corrective action prior to interconnecting the products.
8. Input power to this product must be provided by one of the following: (1) a UL
Listed/CSA certified power source with a Class 2 or Limited Power Source (LPS)
output for use in North America, or (2) a certified transformer, with a Safety Extra
Low Voltage (SELV) output having a maximum 240 VA available, for use in the
country of installation.
9. In addition, since the equipment is to be used with telecommunications circuits,
take the following precautions:
— Never install telephone wiring during a lightning storm.
— Never install telephone jacks in wet locations unless the jack is specifically
designed for wet locations.
— Never touch uninsulated telephone wires or terminals unless the telephone
line has been disconnected at the network interface.
— Use caution when installing or modifying telephone lines.
— Avoid using a telephone (other than a cordless type) during an electrical
storm. There may be a remote risk of electric shock from lightning.
— Do not use the telephone to report a gas leak in the vicinity of the leak.
Download from Www.Somanuals.com. All Manuals Search And Download.
17
Declaration of Conformity
This Declaration of Conformity is made by Paradyne Corporation pursuant to Parts 2
and 15 of the Federal Communications Commission’s Rules. This compliance
information statement pertains to the following products:
Trade Name:
Hotwire
Model Number: 5620-A2-200
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
The name, address, and telephone number of the responsible party is given below:
Paradyne Corporation
8545 126th Avenue North
Largo, FL 33773-1502
Phone: (727) 530-2000
The authority to operate this equipment is conditioned by the requirement that no
modifications will be made to the equipment unless the changes or modifications are
expressly approved by Paradyne Corporation.
In order to maintain compliance with Part 15, FCC rules, the clamp-on ferrite chokes
must be installed on the Ethernet cable and the Power cable in accordance with the
installation instructions.
Download from Www.Somanuals.com. All Manuals Search And Download.
18
Canada EMI Warnings
!
WARNING:
To Users of Digital Apparatus in Canada:
This Class B digital apparatus meets all requirements of the Canadian
interference-causing equipment regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du
règlement sur le matérial brouilleur du Canada.
Notice to Users of the Canadian Telephone Network
The Industry Canada label identifies certified equipment. This certification means that
the equipment meets telecommunications network protective, operational and safety
requirements as prescribed in the appropriate Terminal Equipment Technical
Requirements document(s). The Department does not guarantee the equipment will
operate to the user’s satisfaction.
Before installing this equipment, users should ensure that it is permissible to be
connected to the facilities of the local telecommunications company. The equipment
must also be installed using an acceptable method of connection. The customer should
be aware that compliance with the above conditions may not prevent degradation of
service in some situations.
Repairs to certified equipment should be coordinated by a representative designated by
the supplier. Any repairs or alterations made by the user to this equipment, or
equipment malfunctions, may give the telecommunications company cause to request
to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of
the power utility, telephone lines and internal metallic water pipe system, if present, are
connected together. This precaution may be particularly important in rural areas.
CAUTION:
Users should not attempt to make such connections themselves, but should
contact the appropriate electric inspection authority, or electrician, as
appropriate.
The Ringer Equivalence Number (REN) assigned to each terminal device provides an
indication of the maximum number of terminals allowed to be connected to a telephone
interface. The termination on an interface may consist of any combination of devices
subject only to the requirement that the sum of the Ringer Equivalence Numbers of all
the devices does not exceed 5.
If your equipment is in need of repair, refer to Warranty, Sales, and Service Information
on page 20.
Download from Www.Somanuals.com. All Manuals Search And Download.
19
Warranty, Sales, and Service Information
Contact your local sales representative, service representative, or distributor directly for
any help needed. For additional information concerning warranty, sales, service, repair,
installation, documentation, training, distributor locations, or Paradyne worldwide office
locations, use one of the following methods:
H
Via the Internet: Visit the Paradyne World Wide Web site at
H
Via Telephone: Call our automated call system to receive current information via
fax or to speak with a company representative.
— Within the U.S.A., call 1-800-870-2221
— Outside the U.S.A., call 1-727-530-2340
Trademarks
All products and services mentioned herein are the trademarks, service marks,
registered trademarks or registered service marks of their respective owners.
Document Feedback
We welcome your comments and suggestions about this document. Please mail them
to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773,
or send e-mail to [email protected]. Include the number and title of this
document in your correspondence. Please include your name and phone number if you
are willing to provide additional clarification.
*5620-A2-GN10-30*
*5620–A2–GN10–30*
Copyright E 1998 Paradyne Corporation
Download from Www.Somanuals.com. All Manuals Search And Download.
20
|