TM
9161 Single T1 Network Access Module (NAM)
Installation Instructions
Document Number 9161-A2-GN10-40
December 1998
Product Documentation on the World Wide Web
We provide complete product documentation online. This lets you search the
documentation for specific topics and print only what you need, reducing the waste of
surplus printing. It also helps us maintain competitive prices for our products.
Select Service & Support → Technical Manuals → T1 Access Multiplexers.
Select the following document:
9161-A2-GH30
Model 916x/926x T1 Access Mux Technical Reference
To request a paper copy of a Paradyne document:
H
H
Within the U.S.A., call 1-800-PARADYNE (1-800-727-2396)
Outside the U.S.A., call 1-727-530-8623
Before You Begin
Make sure you have:
-
An operable T1 network connection
-
An async (VT100-compatible) terminal emulator
-
Housing and other associated hardware
-
Applicable cables
Package Checklist
Verify that your package contains the following:
-
T1 NAM and associated I/O card
-
Network Interface Cable (14 ft.)
-
V.35 Interconnect Cable (1 ft.)
-
DB9 COM Port Cable (14 ft.)
-
Affidavit Requirements for Connection to Digital Service
Download from Www.Somanuals.com. All Manuals Search And Download.
1
Cables You May Need
The following cables and connectors are specifically for this product. See Warranty,
Sales, and Service Information on page 15 for ordering information. See the Technical
Reference for all cable pin-out information.
If connecting to a . . .
You need a . . .
Terminal/printer (DB25
interface/connector – EIA-232
connection)
COM Port-to-Terminal/Printer cable (14 ft.)
PC (DB9 interface/connector – COM Port-to-PC cable (14 ft.)
EIA-232 connection)
DTE with a V.35
interface/connector
MS34 to DB25 adapter cable for each port: Port 1
and/or Port 2 (1 ft.)
DTE with a RS-449
interface/connector
DB37 to DB25 DTE adapter cable for each port:
Port 1 and/or Port 2 (1 ft.)
DTE with a V.11/X.21
interface/connector
DB15 to DB25 adapter cable for each port: Port 1
and/or Port 2 (1 ft.)
LAN Adapter
COM Port-to-LAN Adapter cable (14 ft.)
Modem cable
Modem (8-pin
modular-to-DB25 connector)
Recommended Order of Installation
1. First, install the I/O card.
2. Connect all cables into the I/O card.
3. Install the NAM.
4. Go to the appropriate housing installation document for power-up verification
procedures:
— 2-Slot Housing Installation Instructions (Document No. 9000-A2-GN15)
— 5-Slot Housing with AC Power Supply Installation Instructions (Document
No. 9000-A2-GN16)
— 5-Slot Housing with DC Power Supply Installation Instructions (Document
No. 9000-A2-GN1C)
— 9000 Series Access Carrier Installation Instructions (Document No.
9000-A2-GN1D)
Download from Www.Somanuals.com. All Manuals Search And Download.
3
Tools Required
H
A small Phillips screwdriver (#1 or #2) to install the T1 NAM
A small, flat-blade screwdriver to install the:
— I/O card
H
— Cable connections
NAM
Rear Panel
Installing the I/O Card
The NAM’s I/O card provides the COM port, network, DSX and
DTE connections. The I/O card inserts directly behind the NAM
that it supports. Slot numbers are identical (in this case, Slot 01)
to facilitate correct installation.
SINGLE
T1 NAM
NET
1. Remove the I/O card from the shipping box. Handle only
NET
by the top and bottom edges to avoid damaging the card.
DBM
(For
2. At the rear of the housing, align the I/O card with the
upper and lower tracks of the slot. Push gently towards
the midplane until it stops and you cannot push the card
any further.
DBM
Future
Use)
DSX
SX
Access Carrier
5-Slot
2-Slot
Port 1
P
O
RT 1
Port 2
COM
P
RT 2
Screws
Screws
Rear View
Screws
COM
97-15748a
3. There are two captive screws on the I/O card. Using a
screwdriver, alternately tighten each screw until the
screws are all the way in.
98-15050-03
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Connecting to the Network
1. Insert the 8-pin connector on the
RJ48C network cable into the NET
interface.
SINGLE
T1 NAM
NET
RJ48C
Jack
NET
2. Insert the other end of the cable into
the RJ48C modular jack.
DBM
DSX
98-15053-02
Connecting to a DTE
If the DTE cable type is
V.35, RS449, or V.11/X.21
(separately orderable):
1. Connect the plug to the
V.35, RS449, or V.11/X.21
end of the adapter
SINGLE
T1 NAM
NET
cable (as appropriate).
DTE
2. Connect the EIA 530A
end of the adapter cable
to PORT 1 or PORT 2.
DBM
V.35, RS-449,
V.11/X.21
DTE
Cable
Adapter Cable
SX
If the DTE cable type is
EIA-530A:
Port 1
Port 2
1. Connect the EIA-530A
end of the DTE cable to
PORT 1 or PORT 2.
RT 1
DTE
RT 2
DTE
Cable
COM
98-15054-02
Download from Www.Somanuals.com. All Manuals Search And Download.
5
Connecting to the DSX
SINGLE
T1 NAM
NET
1. Insert the DB15 end of the DSX
cable into the DSX interface.
2. Insert the other end of the cable
into the CPE (Customer Premises
Equipment, such as a PBX).
DBM
DSX
PBX
X
P
O
RT 1
98-15055-02
Connecting the COM Port to a User Interface
1. Insert the 8-pin end of the cable into the COM port.
2. Insert the other end of the cable into the user interface (VT100-compatible terminal
emulation) connector.
3. Press Return on the keyboard to display the Main Menu. If you need to configure
for other than a direct link, see the Technical Reference.
COM Port-to-Terminal/Printer
Cable or
COM Port-to-PC Cable
COM
P
RT 2
*
COM
496-15052-01
Set the speed of the async (VT100-compatible) terminal so
it matches the NAM's factory-loaded data rate of 19.2 kbps,
character length set to 8, parity set to None, and stop bits
set to 1. The flow control should be set to None or
Hardware.
*
Download from Www.Somanuals.com. All Manuals Search And Download.
6
Installing the T1 NAM
In both the 2- and the 5-slot housings, the NAM is always installed in Slot 01. The NAM
can be installed in any slot in the access carrier.
!
WARNING:
Do NOT remove any jumpers located on the battery. To do so can cause
non-volatile memory loss. Should a jumper become separated from the
battery, contact your service representative immediately.
CAUTION:
Be sure that you install the NAM in the correct slot so that it mates with its
matching I/O card. Otherwise, you could damage your card.
1. Remove the housing’s bezel, if applicable. See the housing installation instructions
for information.
2. Remove the NAM from the shipping box. Handle only by the top and bottom edges
to avoid damaging the card.
3. At the front of the housing, align the NAM with the upper and lower tracks of
the appropriate slot.
2-Slot
5-Slot
Access Carrier
Ejector
Latches
Ejector
Latches
Ejector
Latches
98-15750-01
Front View
4. Slide into the tracks until the NAM seats with the midplane connectors. Be careful
not to force the card or bend any pins.
5. Close both the upper and lower ejector latches on the housing to lock in place,
then tighten the captive screws on the ejector latches.
6. Replace the housing’s bezel, if applicable.
Download from Www.Somanuals.com. All Manuals Search And Download.
7
Removing/Replacing a Card
Card removal procedures differ, depending on whether you are removing the card from
the front or rear of the housing.
If you are removing the . . .
Then go to . . .
NAM
Removing/Replacing the NAM.
Removing/Replacing the I/O Card.
I/O card
Removing/Replacing the NAM
1. Remove the housing’s bezel, if applicable. See the housing installation instructions
for information.
2. Remove the captive screws from the ejector latches on front of the housing.
3. Press open the ejector latches to disengage the card.
4. Supporting the card by its edges, pull straight out until the card clears the housing.
5. Align the replacement card with the upper and lower tracks of the slot. Slide
forward until the NAM seats. Be careful not to force or bend any pins.
6. Close both the upper and lower ejector latches on the housing to lock in place,
then tighten the captive screws.
7. Replace the housing’s bezel, if applicable.
Removing/Replacing the I/O Card
1. Remove the NAM from the housing (see Removing/Replacing the NAM).
2. Remove the network, DSX-1, DTE, and COM port cables from the I/O card (if
applicable).
3. Using a screwdriver, loosen the upper and lower screws fastening the card to the
housing’s frame.
4. Gently pull the I/O card away from the midplane until it clears the housing.
5. Align the replacement I/O card with the upper and lower tracks of the slot. Push
gently towards the midplane until it stops and you cannot push the card any further.
6. Alternately tighten each captive screw until the screws are all the way in.
7. Reattach the cables as appropriate.
8. Reinstall the NAM.
Power-Up
Go to your housing instructions to perform power-up, if needed. The housing
instructions also contain troubleshooting information.
Download from Www.Somanuals.com. All Manuals Search And Download.
8
Front Panel LEDs and Test Jacks
The T1 NAM has 12 LED (light-emitting diode) status indicators and four sets of test
jacks.
Test Jacks
The NAM contains four sets of test jacks. Use these for:
IN
NET
OUT
H
Monitoring and testing towards the Network 1 interface
carrier
IN
DSX
H
Monitoring and testing towards the Network 2 interface
carrier
OUT
Test
Jacks
IN
NET
MON
OUT
Refer to Troubleshooting and Maintenance in the Technical
Reference for more information on the test jacks.
IN
DSXMON
OUT
General Status LEDs
961
OK
Label Indication Color
What It Means
ALM
OK
Power and Green
Operational
Status
ON – NAM has power
and is
TST
BKP
SIG
operational.
NTEWORK
OFF – NAM is in a
power-up
OOF
ALM
SIG
OOF
ALM
1–
LEDs
self-test, or there
is a failure.
DXS
CYCLING – The unit is in
Minimum mode.
Requires an FTP
download.
OK
PRO
2–
T
O
K
ALM
TST
System
Failure/
Self-Test
Red
ON – NAM has just
been reset, or an
error or fault has
been detected.
496-15051
OFF – No failures have
been detected.
Test Mode Yellow
ON – Loopback or test
pattern in
progress,
initiated locally,
remotely, or from
the network.
OFF – No tests are
active.
BKP
Backup
Yellow
Not supported. Remains
off except during a Lamp
Test.
Download from Www.Somanuals.com. All Manuals Search And Download.
9
Network and DSX Interface LEDs
Label
Indication
Color
What It Means
SIG
Signal
Green
ON – A recoverable signal is present on
the network/DSX interface.
OFF – The signal cannot be recovered
from the network/DSX interface. An
LOS condition exists.
OOF
ALM
Out of Frame
Alarm
Yellow
Yellow
ON – At least one OOF was detected
during the sampling period.
OFF – No OOFs were detected during the
sampling period.
ON – An alarm condition is present on the
network/DSX interface.
Current alarm conditions:
H Loss of Signal (LOS)
H Loss of Frame (LOF)
H Excessive Error Rate (EER)
H Yellow Alarm
H Alarm Indication Signal (AIS)
OFF – No alarm condition is present on
the network/DSX interface.
Port 1 and Port 2 LEDs
Label
Indication
Color
What It Means
1-OK
2-OK
Operational
Status
Green
ON – The interchange circuits for the port
are in the correct state to transmit
and receive data.
OFF – The port is idle. Occurs if the port is
disabled, if an EDL Out of Frame or
EER condition is present, if a DCLB
is active, or if the port is configured
to monitor DTR and/or RTS and the
lead(s) is not asserted.
Download from Www.Somanuals.com. All Manuals Search And Download.
10
Troubleshooting
Symptom
Possible Cause
Solutions
No power, or none of the For DC power source, DC
Check the DC power
source.
system LEDs are lit.
power is not present.
For AC power source, the
wall receptacle has no
power, or the housing’s
power cord is not securely
plugged into the wall
receptacle or the back of
the housing.
1. Check the wall
receptacle power by
plugging in some
equipment that is known
to be working.
2. Check that the power
cord is securely attached
at both ends.
3. Check the circuit
breaker.
Run the Lamp Test. If the
LED in question does not
flash with the other LEDs,
then contact your service
representative.
LED is burned out.
Power-Up Self-Test fails. The NAM has detected an
1. Reset the NAM and try
again (see the Technical
Reference).
Only Alarm LED is on
internal hardware failure.
after power-up.
2. Contact your service
representative.
Cannot access the NAM Login or password is
1. Reset the NAM (see the
Technical Reference).
or the user interface.
incorrect, COM port is
misconfigured, or the NAM
otherwise configured so it
prevents access.
2. Contact your service
representative.
Device Fail appears on
the System Health and
Status screen.
The NAM detects an
internal hardware failure.
Record the 8-digit code
from the System Health
and Status screen, then
contact your service
representative.
Not receiving data at
DTE or DSX-1 interface. correct timeslot(s).
Not cross-connected to the Verify cross connections
using the Cross Connect
configuration option.
Download from Www.Somanuals.com. All Manuals Search And Download.
11
Technical Specifications
Specification
Criteria
Weight
T1 NAM
T1 I/O card
1 lb. 2 oz. (.51 kg)
6 oz. (.17 kg)
Size
T1 NAM
T1 I/O card
11.58″ x 8.00″ (29.41 cm x 20.32 cm)
2.90″ x 10.15″ (7.37 cm x 25.78 cm)
Power Consumption
9.4 watts, 0.78 amps input current at 12 volts
Physical Environment
Operating temperature
Storage temperature
Relative humidity
35°F to 122°F (1.7°C to 50°C)
–4°F to 158°F (–20°C to 70°C)
5% to 85% (noncondensing)
Shock and vibration
Withstands normal shipping and handling
Network T1 Interface
Physical Interface (USA)
Physical Interface (Canada)
Framing Format
RJ48C
CA81A using adapter cable
D4, ESF
AMI, B8ZS
Coding Format
Line Build-Out (LBO)
ANSI PRM
Bit Stuffing
0.0 dB, –7.5 dB, –15 dB, –22.5 dB
Selectable
FCC Part 68, AT&T TR 62411
Selectable
Yellow Alarm Generation
DSX-1 Interface
Physical Interface
Framing Format
Coding Format
DB15 socket
D4, ESF
AMI, B8ZS
DTE Line Equalization
5 selectable ranges from 0 to 655 feet
(0 to 196.5 meters)
Selectable
Send AIS
DTE Ports/Interfaces
Standards
Rates
EIA-530A, V.35, RS-449, V.11, X.21
Nx64 – 64K to 1.536 Mb
Nx56 – 56K to 1.344 Mb
COM Port/Interface
Data Rates
9.6, 14.4, 19.2, 28.8, 38.4 , 57.6, 115.2 kbps
57.6, 115.2 kbps are recommended for FTP
download only
Download from Www.Somanuals.com. All Manuals Search And Download.
12
Specification
Criteria
DBM (Backup) connector
One 8-position modular keyed USOC RJ45 jack
(reserved for future use)
Clocking Sources
T1 network interface, any port, internal clock, DSX-1
T1 interface or external clock
Loopbacks
Standard
Network Line Loopback, Network Payload
Loopback, V.54 Loop 2 (DCLB) and V.54 Loop 3
(DTPLB)
Additional
Network Repeater Loopback, DSX-1 Line Loopback
DSX-1 Payload Loopback, DSX-1 Repeater
Loopback, DTE Loopback
Pin Assignments
NET Port/Interface
Function
Circuit
Pin #
Receive ring from the network
Receive tip from the network
Transmit ring to the network
Transmit tip to the network
R1
T1
R
1
2
4
5
T
COM Port/Interface
Signal
Direction
Pin #
DCE Transmit Clock (TXC)
DCE Receive Data (RXD)
Signal Ground (SG)
Out
Out
—
1
2
3
4
5
6
7
8
DCE Transmit Data (TXD)
DCE Data Terminal Ready (DTR)
DCE Carrier Detect (CD)
DCE Request to Send (RTS)
DCE Receive Clock (RXC)
In
In
Out
In
Out
Download from Www.Somanuals.com. All Manuals Search And Download.
13
DSX Port/Interface
Function
Circuit
Pin #
1
Receive tip from the DTE
Receive ring from the DTE
Transmit tip to the DTE
Transmit ring to the DTE
Shield
T1
R1
T
9
3
R
11
2,4
–
DTE Ports/Interfaces
Circuit
Mnemonic CCITT #
ITU/
25-Pin
Pin #
Signal
Direction
—
Shield
—
—
1
Transmitted Data (TXD)
BA
103
To DCE
2 (A)
14 (B)
Received Data (RXD)
Request to Send (RTS)
Clear to Send (CTS)
BB
CA
CB
CC
104
105
106
107
From DCE 3 (A)
16 (B)
To DCE
4 (A)
19 (B)
From DCE 5 (A)
13 (B)
Data Set (or DCE) Ready
(DSR)
From DCE
6
Signal Ground/Common (SG) AB
102A
109
—
7
Received Line Signal Detector CF
(RLSD or LSD)
From DCE 8 (A)
10 (B)
Transmit Signal Element
Timing (TXC – DTE Source)
DA
DB
DD
113
114
115
To DCE
11 (B)
24 (A)
Transmitter Signal Element
Timing (TXC – DCE Source)
From DCE 12 (B)
15 (A)
Receiver Signal Element
Timing (RXC – DCE Source)
From DCE 17 (A)
9 (B)
Local Loopback (LL)
LL
141
To DCE
To DCE
18
20
Data Terminal (or DTE)
Ready (DTR)
CD
108/1, /2
Remote Loopback (RL)
Signal Common
RL
AC
TM
140
To DCE
—
21
102B
142
22, 23
Test Mode Indicator (TM)
From DCE 25
Download from Www.Somanuals.com. All Manuals Search And Download.
14
Warranty, Sales, and Service Information
Contact your local sales representative, service representative, or distributor directly for
any help needed. For additional information concerning warranty, sales, service, repair,
installation, documentation, training, distributor locations, or Paradyne worldwide office
locations, use one of the following methods:
H
Via the Internet: Visit the Paradyne World Wide Web site at
H
Via Telephone: Call our automated call system to receive current information via
fax or to speak with a company representative.
— Within the U.S.A., call 1-800-870-2221
— Outside the U.S.A., call 1-727-530-2340
Document Feedback
We welcome your comments and suggestions about this document. Please mail them
to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773,
or send e-mail to [email protected]. Include the number and title of this
document in your correspondence. Please include your name and phone number if you