AHR5
V-ROTARY
HIGH CONTACT PRESSURE
WITH LIGHT OPERATING
ACTION
ACTION(AHR5)
SWITCHES
FEATURES
TYPICAL
• High contact pressure with light oper-
ating action
APPLICATIONS
• Vending machines
• Easy installation of the lever—Tools
or adhesives are unnecessary for at-
taching the actuating lever
• Low-level circuit type is also available
The AHR5 switch with actuating
lever and retainer assembled
CONSTRUCTION
Rotating
Actuating spring
Movable contact
shaft
Handle
Solder and
Q.C. (187)
N.O. terminal
Pin
plunger
Common
terminal
N.C. terminal
Operating spring
Restoration
spring
Stationary
contact
PRODUCT TYPES
SPDT .187 Quick-connect/
Release force (min.)
Type
Retainer mounting direction
Operating force (max.)
solder terminal
Counter-clockwise
Clockwise
AHR5401
Standard (Silver alloy)
AHR5411
0.013N•cm {1.3gf•cm}
0.1N•cm {10.2gf•cm}
Counter-clockwise
Clockwise
AHR540161
Low-level circuit type
(Gold clad)
AHR541161
AHR5801
Actuator lever
52.3mm 2.059inch
—
Remarks: 1. The retainer is provided with the switch body without assembled.
2. Actuating levers are available separately.
(AHR5801, length: 52.3mm 2.059inch)
3. As for International standard, please refer to the “Information”.
SPECIFICATIONS
1. Contact rating (Resistive load)
Type
Standard rating
Low-level rating
Standard (Silver alloy)
5A 250V AC
6V DC 5mA
12V DC 2mA
24V DC 1mA
Low-level circuit type (Gold clad)
1A 250V AC
75
Download from Www.Somanuals.com. All Manuals Search And Download.
11/2002
AHR5
NOTES
1. Method of attaching actuating lever
Insert tha lever in the rotating spindle,
then place the retainer over the spindle to
lock the lever in place as shown in Fig. 1.
Be sure that the retainer has snapped
over the lugs on the rotating spindle, with
the lugs entering fully into the holes in the
retainer.
4. Regarding switch mounting
Mount the switch to a smooth surface us-
ing M3 screws.Tighten the screw with 3 to
5 kg-cm torque. To prevent loosening of
the mounting screws, it is recommended
that spring washers be used in combina-
tion with adhesive material for locking the
screws.
In the mounted condition, the insulating
distance between each terminal and
ground should be checked for assurance
of proper distance.
Retainer
Hole (2 places)
5. Regarding changes in operating
characteristics
Actuating lever
When selecting theV rotary action switch,
allow 20% to the rated operating and re-
lease forces.
Rotating spindle
(Example)
Lug section (2 places)
OF: 10.2 g-cm max. specification
10.2 × (100+20%) = 12.24 g-cm
RF: 1.3 g-cm min. specification
1.3 g-cm × (100–20%) = 1.04 g-cm
6. Adjustment of the operating object
The positioning of the operating object
should be such that when direct force is
not applied to the actuator, the actuator is
in its free position. The operating object
should apply force in the operating direc-
tion. The standard value of overtravel to
be used should be set within the range of
70% to 100% of the rated O.T. value. Fur-
thermore, if the operating position limit is
exceeded, the electrical and mechanical
life of the switch will be shortened.
7. Avoid usingV Rotary switches in the
following conditions:
2. Regarding the actuating lever
As an accessory, the standard lever
(Product No. AHR5801) is available sepa-
rately.
0.7 DIA. .028 DIA.
Stainless steel
Standard lever
AHR5801
52.3
2.059
At time of mounting,
50 mm from center of rotating spindle
3. Cautions regarding design of actuat-
ing lever
The dimensions of the lever at the mount-
ing section are as shown in Fig. 2. These
dimensions should be used in the design
of an alternate actuating lever. The mate-
rial can be stainless steel wire or piano
wire. The standard lever length is 50 mm
1.969 inch. A lever in excess of this length
would have a weight which could cause
erroneous operation.
• Where the ambient temperature ex-
ceeds the range of –25°C to +65°C –13°F
to +149°F.
• Where the relative humidity exceeds
85%.
• Where the permissible operating speed
of 1 to 100°/sec. is exceed.
• Where the operating speed of 240 cpm.
is exceeded.
• Where the lever length of 50mm
1.969inch is exceeded.
1.2 0.2
.047 .008
Less than
0.5R
.020R
d = 0.7 0.015 DIA.
d = .028 .001 DIA.
90°
77
Download from Www.Somanuals.com. All Manuals Search And Download.