Interface Adapter
Model
AK-HTF900P
Before attempting to connect, operate or adjust this product,
please read these instructions completely and save this manual for future use.
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
For Your Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Precautions for Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Controls and their Functions
_ Front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
_ Rear panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
How To Connect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Appearance and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Outline
≥ This unit is able to separate multiple data (camera control data and swivel stand control
data) transmitted from the camera controller (AK-HRP900P), and to output the control
information to the multi-purpose camera (AK-HC900P) and the swivel stand (AW-
PH300A, etc.).
≥ The distance between this unit and the camera is 33 ft (10m) max.
Precautions for Use
≥ We recommend that the AC adapter AW-PS505P is used for power supply.
≥ Handle the unit with care.
If dropped or given a strong shock, it may cause a trouble or accident.
≥ Use the unit in a temperature range of 32oF to 104oF (0oC to + 40oC).
If used at a temperature below 32oF or higher than 104oF, it may cause bad influences to
the component parts.
≥ Turn off the power before connecting or disconnecting the cable.
When connecting or disconnecting the cable, be sure to turn off the power switch of the
unit beforehand.
≥ Avoid using the unit outdoors.
≥ Install the unit 3.3 ft (1 m) away from the monitor.
≥ Maintenance
Pull out the power cord plug and clean the unit with dry cloth. If it is hard to clean,
moisten the cloth with a diluted neutral detergent solution and squeeze it well and lightly
wipe the unit.
Precautions
≥ Do not use volatile solvents such as benzene or thinner.
≥ When using a chemical mop, carefully read the instructions.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Controls and their Functions
_Front panel
POWER
OFF
ON
Interface Adapter
1
2
1 Power indication LED [POWER]
When the power control switch 2 is ON, it is lighted green. With the power control
switch 2 set to OFF, it goes out.
2 Power control switch [POWER ON/OFF]
When this switch is set to ON, this unit and the camera connected to it are turned on.
With the switch set to OFF, both of the unit and the camera are tuned off.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Controls and their Functions
_Rear panel
CAMERA
CN
DATA IN
BEAKER
DC 12V
IN
PAN/TILT
CONTROL OUT
6
3
4
5
7
3 Camera connector [CAMERA I/F]
Connected to the camera (AK-HC900P) with the attached multi-cable.
Pin No
Signal
Pin No
8
Signal
15 14 13 12 11 10 9
8
1
2
3
4
5
6
7
NC
NC
NC
NC
NC
NC
NC
NC
7
6
5
4
3
2
1
9
10
11
12
13
14
15
DC 12V
DC GND
TXD (C)
RXD (H)
RXD (C)
Frame GND
TXD (H)
TXD: Data from camera to remote controller.
RXD: Data from remote controller to camera.
4 Swivel stand control signal output connector [PAN/TILT CONTROL OUT]
Connected to the swivel stand.
5 Control data input connector [DATA IN]
Used to input the data multiplexed by the camera controller (AK-HRP900P).
Pin No Signal
Pin No
8
Signal
15 14 13 12 11 10 9
8
1
2
3
4
5
6
7
NC
NC
NC
NC
NC
NC
7
6
5
4
3
2
1
NC
9
NC
10
11
12
13
14
15
NC
NC
Frame GND
TXD (H)
TXD (C)
RXD (H)
RXD (C)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Controls and their Functions
6 Breaker [BREAKER]
DC power breaker. The breaker operates to cut off the power in case of over-current.
7 DC12V input connector [DC 12V IN] (XLR4-pin)
Connects the AC adapter. We recommend that the AW-PS505P (option) is used.
Pin No
Signal
4
1
2, 3
4
GND
–––
1
3
2
12V
6
Download from Www.Somanuals.com. All Manuals Search And Download.
How To Connect
Remote
control
spec. lens
Multi-cable (17ft)
AK-HDMLTCA05
HD-SDI
B
R
E
A
K
E
/
R
Z
F
O
O
O
C
M
S
U
Coaxial cable (5C-FB)
1
2
S
D
I
O
U
T
Interface adapter
AK-HTF900P
1
/
F
Multi-purpose digital camera
AK-HC900P
Remote
(zoom/focus
control) cable
Trans-
mission
O
I
AC adapter
N D / E X T
AW-PS505P
I N
S D I
Multi-cable (17 ft)
L E N S E I / F
I / F
C A M E R A
AK-HDMLTCA05
D
C
I
1
2
V
C
O
N
I
T
P
R
O
L
I
N
N
HD monitor
1394
/
RP
C
S
OP
G/L
I
N
P
b
OUT
P
r
/
SDI
Y
/
VIDEO
OUT
OUT
O
I
Swivel stand
AW-PH300A
O
I
AC adapter
AW-PS505P
AC adapter
AW-PS300
Camera Controller
ON
OFF
SCENE
USER1
OPERATE
CAM
POWER
ALARM
TEST
PRE
USER2
SD CARD
Swivel stand control is
possible for AW-
PH500/PH600 as well.
MODE
BAR
AUTO
WHITE
BLACK
TALLY
GAIN
BLACK
MENU
ON
MENU
4
ND FLTER
1/16 1/32
CC FLTER
3200 4300 6300 CROSS
1
0
1
/
4
PRESET
3
DDC
power
cable
1
2
5
GAIN
9dB
SHUTTER
OFF STEP SYNCRO
18dB
SPEED
TELE
ZOOM
FOCUS
S1
S2
S3
CHECK
FAR
I
R
I
S
M-PED
AUTO
WIDE
NEAR
Swivel stand controller
AW-RP301
Camera controller
AK-HRP900P
AC adapter
AW-PS301
≥ Make the connections with all the units turned off.
≥ We recommend that the AW-PS505P (option) is used as AC adapter
≥ Use a swivel stand, AW-PH300A, AW-PH500, AW-PH600, and an adapter suited for the
swivel stand.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Appearance and Dimensions
(
): mm
O U T
C O N T R O L
A P N / T I L
T
I N
D C 1 2 V
C N
B E A K E R
I N A T D A
C A M E R A
POWER
OFF
ON
Interface Adapter
8-3/16z (206.5)
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
Power supply:
DC +12V (XLR 4-pin connector)
Power consumption: 25 W (with camera connected)
1is the safety information.
Swivel control output:
Switch function:
Control signal (RJ-45 8P modular jack)
Power control
Cable max. extension distance: 33 ft (10m)
Operating temperature:
Dimensions:
32oF to 104oF (0oC to +40oC)
8-3/16(W)k2-1/8(H)k9-7/8(D) inch
(206.5k52.7k250 mm)
Weight:
Finish:
Approx. 4.18 lbs (1.9 kg)
AV ivory coating (Munsell 7.9Y 6.8/0.8 approx. color)
Weight and dimensions shown are approximate.
Specifications are subject to change without notice.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Memo
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Memo
11
Download from Www.Somanuals.com. All Manuals Search And Download.
PANASONIC BROADCAST & TELEVISION SYSTEMS COMPANY
UNIT COMPANY OF MATSUSHITA ELECTRIC CORPORATION OF AMERICA
Executive Office:
One Panasonic Way 4E-7, Secaucus, NJ 07094 (201)348-7000
EASTERN ZONE
One Panasonic Way 4E-7, Secaucus, NJ 07094 (201)348-7621
Southeast Region:
1225 Northbrook Parkway, Ste 1-160, Suwanee, GA 30024 (770) 338-6835
Central Region:
1707 N Randall Road E1-C-1, Elgin, IL 60123 (847) 468-5200
WESTERN ZONE:
3330 Cahuenga Blvd W., Los Angeles, CA 90068 (323) 436-3500
Government Marketing Department:
52 West Gude Drive, Rockville, MD 20850 (301) 738-3840
Broadcast PARTS INFORMATION & ORDERING:
9:00 a.m. – 5:00 p.m. (EST) (800) 334-4881/24 Hr. Fax (800) 334-4880
Emergency after hour parts orders (800) 334-4881
TECHNICAL SUPPORT:
Emergency 24 Hour Service (800) 222-0741
Panasonic Canada Inc.
5770 Ambler Drive, Mississauga, Ontario L4W 2T3 (905) 624-5010
Panasonic de Mexico S.A. de C.V.
Av angel Urraza Num. 1209 Col. de Valle 03100 Mexico, D.F. (52) 1 951 2127
Panasonic Sales Company
Division of Matsushita Electric of Puerto Rico Inc.
San Gabriel Industrial Park, 65th Infantry Ave., Km. 9.5, Carolina, Puerto Rico 00630 (787) 750-4300
Printed in Japan
VQT0A80
@3
F0902H
Download from Www.Somanuals.com. All Manuals Search And Download.
|