| NICKEL METAL HYDRIDE BATTERIES: INDIVIDUAL DATA SHEET   Typical Charge Characteristics   HHR300CH   Cylindrical C size (HR 26/50) for backup use   Dimensions (with Tube)   (mm)   2.0   1.8   1.6   Charge: 300mA(0.1 It) x 16hrs.   1.4   1.2   25.8+   0 - 1.0   10˚C   25˚C   60˚C   1.0   0.8   (+)   0 2 4 6 8 10   20   30   40   50   60   Charge Time (hours)   50.0+   0 - 1.5   Typical Discharge Characteristics   120   110   100   90   80   70   ( )   Specifications   Charge: 300mA (0.1 It) x 16 hrs.   Charge Temperature: -10 to 60˚C   Discharge: 600mA (0.2 It)   Cut-off Voltage: 1.0V   Discharge Temperature: 25˚C   60   50   40   30   mm   inch   25.8+0/-1.0   50.0+0/-1.5   Grams   1.02+0/-0.04   1.97+0/-0.06   Ounces   Diameter   Height   -20   -10   0 10   20   30   40   50   60   70   Approximate   Weight   Temperature (°C)   80   2.82   Nominal Voltage   1.2V   Average2   3300 mAh   3100 mAh   Discharge   Capacity1   Rated (Min.)   1.8   Charge: 300mA(0.1It) x 16 hrs., 25°C   Discharge: 10A, 20A, 25°C   Approx. Internal impedance   at 1000Hz at charged state.   5mΩ   1.6   1.4   1.2   1.0   0.8   300mA (0.1It) x 16hrs.   1500mA (1It) x 2.4 hrs.4   Standard   Rapid3   Charge   155mA x 32 hrs.   100mA x 48 hrs.   Low Rate   F ˚ C ˚ Standard   32˚F to 113˚F   32˚F to 104˚F   14˚F to 149˚F   14˚F to 113˚F   -4˚F to 95˚F   -4˚F to 95˚F   -4˚F to 131˚F   0˚C to 45˚C   Charge   Rapid   10A   20A   10˚C to 40˚C   Low Rate   Discharge   < 1 year   -10˚C to 45˚C   -10˚C to 65˚C   -20˚C to 35˚C   -20˚C to 35˚C   -20˚C to 55˚C   0 5 10   15   20   25   30   Discharge Time (minutes)   Storage   < 3 months   < 1 month   1 2 3 After charging at 0.1It for 16 hours, discharging at 0.2It.   For reference only.   Need specially designed control system   Control System:   Note: [It] was previously expressed as [C]. [It] is an IEC standard expression   for the amount of charge or discharge current and is expressed as:   It(A) = Cn (Ah)/1h.   dT/dt cut-off; 1 to 2°C/min   -UV cut-off; -UV per cell = 5 to 10 mV   T-control; T=65°C   Rapid charger timer; 2.4h (at 1.25a)   Trickle timer; within 2h   • [It] is the reference test current in ampres   • [Cn] is the rated capacity of the cell or battery in Ampere-hours.   n = the time base [hours] for which the rated capacity is declared   4 With control system   Battery performance and cycle life are strongly affected by how they are used. In   order to maximize battery safety, please consult Panasonic when determining   charge / discharge specs, warning label contents and unit design.   AUGUST 2005   NICKEL METAL HYDRIDE HANDBOOK   modification without notice. Contact Panasonic for the latest information.   This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to   Download from Www.Somanuals.com. All Manuals Search And Download.   |