Omnitron Systems Technology TV Converter Box OmniHawk User Manual |
________________________________________________________________________
OmniHawk™ 4/16 Token Ring
Fiber Converter
User’s Manual
___________________________________________________
27 Mauchly, Suite #201, Irvine, CA 92618
Document # 040-00039-001
( 714) 250-6510
Download from Www.Somanuals.com. All Manuals Search And Download.
TECHNICAL SUPPORT
If you encounter any problems in installing or maintaining this equipment,
do not hesitate to call, fax or write Omnitron’s technical support:
OmniHawk™ 4/16 Token Ring
Fiber Converter
Omnitron Systems Technology, Inc.
27 Mauchly, Suite 201
Irvine, CA 92618
Phone: 714-250-6510
Fax:
714-250-6514
USER’S MANUAL
GENERAL DESCRIPTION
The OmniHawk™ 4/16 Token Ring fiber converter provides a solution to
heterogeneous Token Ring media environments. Conversions between
copper (CAT-5 or Type 1) and fiber optic interfaces are required in most
modern Token Ring installations.
Fiber optic cabling is the media of choice for connecting separate buildings
within a campus network. Even trunk connections between floors of a single
building benefit from the advantages of fiber optic media. In heavy industrial
settings, fiber optic media may provide the only reliable connectivity even
when the distances traveled are short. Moreover, a growing number of work-
station interface cards now feature fiber optic connection.
The OmniHawk™ is packaged for a wide variety of media conversion appli-
cations. It can be wall mounted, rack mounted, or attached directly to the
DB9 connector of a workstation.
ALWAYS CONNECT
The OmniHawk™ is specifically designed with an intelligent connection al-
gorithm which assures dependable communications. Whether it is attached
to passive or active devices, the OmniHawk™ will always make a good
connection. The fiber optic interface adheres to the IEEE 802.5j specifica-
tion for fiber optic attachment.
12
1
Download from Www.Somanuals.com. All Manuals Search And Download.
CONNECTORS, SWITCHES & INDICATORS
TECHNICAL SPECIFICATIONS
CONNECTORS
The OmniHawk™ has three interface connectors: a fiber optic transmitter
and receiver pair, an RJ45 jack, and a DB9 male connector.
•
•
Protocol:
Cables
Token Ring (IEEE 802.5)
Fiber Optic:
Multi-mode glass fiber of sizes 50/125,
62.5/125, or 100/140 micron
DB9 female
The DB9 connector and the chassis are designed to attach directly to the
rear of a workstation network interface card. The jack screws ensure a solid
connection.
STP:
UTP:
CAT-5 (EIA/TIA 568):
(lower grade wiring at shorter distances)
The RJ45 connector is designed to attach directly to a hub lobe or ring out
via a CAT-5 patch cable. The RJ45 connector may attach to a ring in with a
crossed patch cable (transmit and receive pairs crossed).
•
•
Data Rate:
16 Mbps or 4 Mbps
Supported Distances
Fiber Optic:
Note that only one copper interface may be used at a time. Other connec-
tions are possible with special cables. Omnitron’s technical support depart-
ment can assist you with your special needs.
2.5 Km multi-mode
20 Km single-mode
300 m
UTP:
SWITCHES
•
Indicators
The OmniHawk™ has two switches which control the attachment mode.
The switches are located to the right of the DB9 connector.
FO Ready
Cu Ready
Power/Error
Insert Status
Yellow - Green LED
Yellow - Green LED
Yellow - Red LED
Yellow - Green LED
•
•
•
Dimensions:
Power:
W: 3.46” x D: 2.83” x H: 0.78”
External Power Supply 9 VDC @ 1.2A
Temperature
Operating:
Storage:
Both switches are placed in the UP position at the factory. The following
table explains the switch settings.
0 to 45 degrees C
-40 to 75 degrees C
ATTACHMENT MODE
Automatic Sensing
SWITCH 1
Up
SWITCH 2
Up
•
Humidity:
Up to 90% (non condensing)
UTP/STP --> RO or Station
UTP/STP --> RI or Lobe
Self Test / Media Test
Up
Down
Up
Down
Down
Down
CONNECTORS
In addition to the two switches there are four LED indicators in a 2 x 2
cluster. Refer to the drawing below.
2
11
Download from Www.Somanuals.com. All Manuals Search And Download.
C. Hub Ring Out (RJ45) to distant hub Ring In (RJ45)
Application C shows the Ring Out of one hub connected to the Ring In of
another hub via a pair of OmniHawk™ converters. Note that the cable from
the second OmniHawk™ to the Ring In is a crossed cable.
D. Distant Lobe Extension
Application D shows a distant hub in lobe extension via a pair of OmniHawk™
converters. In this configuration a standard CAT-5 cable connects the ex-
tended hub to the first OmniHawk™, fiber optic cables connect the two
converters, and another standard CAT-5 patch cable connects the second
OmniHawk™ to the target hub.
The bottom left LED is yellow / red, the remaining three LEDs are yellow /
green. The meaning of the LEDs are shown on the cover of the OmniHawk™
and in the tables below.
POWER UP LED TEST
E. Other Applications
The above examples show the most common applications of the
OmniHawk™. Your network may require an application not listed here. The
configuration you need will be supported by the OmniHawk™ as long as
the correct cable is used. The fiber optic cables will always be the same.
The table below will guide you in selecting the proper copper cables, media
filters, and connector adapters.
ALL LEDS
MEANING
Yellow for 1/2 second then Green or Red
or 1/2 second
Self Test OK
Any other behavior
Failed Self Test, Call Technical Support
The OmniHawk™ performs a self test every time power is newly applied.
OST PART #
CONNECT FROM
CONNECT TO
9300-P45
OmniHawk™ RJ45 Lobe, RJ45
OmniHawk™ RJ45 Ring Out, RJ45
OmniHawk™ RJ45 Ring In, RJ45
OmniHawk™ RJ45 Workstation, RJ45
OmniHawk™ RJ45 Workstation, DB9(if not directly
attaching the OmniHawk™ to the
workstation)
OPERATIONAL MODES
9301-P45X
FIBER READY
(top left)
COPPER READY
(top right)
MEANING
MEANING
5700-CMF &
9301-P45X
Data received from
fiber
Data received from
copper
GREEN
Off
GREEN
OFF
5701-IP45 &
9300-P45
OmniHawk™ RJ45 Lobe, IBM Data Connector
No data is being
received from Fiber
No data is being
received from copper
OmniHawk™ RJ45 Ring Out, IBM Data Connector
OmniHawk™ RJ45 Ring In, IBM Data Connector
POWER /
ERROR (bot.
left)
5701-IP45 &
9301-P45X
INSERT STATUS
(bot. right)
MEANING
MEANING
9310-IF9
OmniHawk™ DB9
OmniHawk™ DB9
OmniHawk™ DB9
OmniHawk™ DB9
Ring In, IBM Data Connector
Ring Out, IBM Data Connector
Lobe, IBM Data Connector
Workstation, DB9(if not directly
attaching the OmniHawk™ to the
workstation)
The fiber optic and
copper interfaces have
both actively inserted
YELLOW
RED
Power is on
GREEN
9311-IF9X
An attachment error
occurred
FLASHING
GREEN
Still attempting to
insert
9320-FM9
Insertion is not being
attempted
OFF
10
3
Download from Www.Somanuals.com. All Manuals Search And Download.
The operational modes are:
APPLICATIONS
The following drawing illustrates three different applications of the
OmniHawk™.
1. AUTOMATIC SENSING
2. UTP/STP —> RO or STATION
3. UTP/STP —> RI or LOBE
The power / error LED turns red when an attachment error occurs. An error
can only occur when attaching to active devices (devices which signal for
insertion with phantom current or the fiber optic key). The error condition
occurs when copper device initiates the phantom current and the fiber optic
device initiates the fiber optic key. In Token Ring, the active insertion pro-
cess may only be directed from one direction.
SELF TEST / MEDIA TEST MODE
COPPER
READY (top
right)
FIBER READY
MEANING
MEANING
(top left)
Data received from
fiber
Data received from
copper
GREEN
GREEN
No data is being
received from fiber
No data is being
received from copper
OFF
OFF
POWER /
ERROR (bot.
left)
INSERT
STATUS (bot.
right)
MEANING
MEANING
The OmniHawk™ is
in the self test /
YELLOW
Power is on
YELLOW
media test mode.
A. STP Workstation (DB9) to distant hub (RJ45)
DIAGNOSTIC FEATURES
The OmniHawk™ diagnostic features make it easy to install and maintain.
There are four levels of diagnostics: Power-On LED Test, Self Test / Media
Test, Installation Test, and run-time ready and error monitoring.
Application A shows an STP workstation connecting via its DB9 connector
directly to one OmniHawk™, which is connected to a second OmniHawk™
via fiber optic cables. The last connection to the hub is made via a standard
CAT-5 patch cable.
B. Fiber optic Workstation to hub (RJ45)
Application B shows a fiber optic workstation connecting to an OmniHawk™
vi its fiber optic cables. The OmniHawk™ connects to the hub via a stan-
dard CAT-5 patch cable.
4
9
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER-ON LED TEST
Every time power is newly applied to the OmniHawk™ the LEDs will flash
through all possible colors to give the user the assurance that other diag-
nostic information may be correctly interpreted. The LEDs will flash all yel-
low, then either green or red. After that, the LED test is over and the LEDs
will illuminate according to the mode (as set by the switches) and the cur-
rent media connections.
SELF TEST / MEDIA TEST
The self test / media test ensures that the OmniHawk™ is fully operational.
Testing occurs when the switches both set to the DOWN position. The bot-
tom two LEDs will both illuminate yellow indicating that power is on and that
the unit is in the test mode. The testing checks both the data passing capa-
bility of the OmniHawk™ and the physical continuity of the media. For both
fiber optic and copper media test data is looped back to the OmniHawk™.
When a looped back fiber cable is connected from the transmit (TX) to the
receive (RX) fiber optic connectors, the fiber optic ready LED lights green.
When a CAT-5 patch cable is connected from the OmniHawk™ to an un-
used lobe of a hub, the copper ready LED lights green. If good connections
are made and the corresponding LED does not illuminate, then the media is
broken. This CAT-5 cable used in this test may be inserted into an operat-
ing hub since the OmniHawk™ will not assert phantom current during the
test mode (and consequently will not enter the network).
To test the integrity of copper patch cables and any intervening baluns con-
nect the OmniHawk™ to an unused lobe of any powered hub. If the cable is
unbroken, the copper ready LED will light green. If the cable is broken, the
LED will be off.
Note that the power / error LED and the test mode LED will both be yellow.
INSTALLATION TEST
NOTE: TURN OFF THE SELF TEST / MEDIA TEST MODE TO RETURN
TO NORMAL OPERATIONAL MODES.
The OmniHawk™ tests for proper installation and lights the power / error
LED red if a wrong connection is made. This check will only be made when
the connecting devices are stations and/or active hubs. Among active de-
vices, there are initiators and echoers. An initiator is a device that either
sends phantom current or the fiber optic insertion key. An echoer is a de-
vice that receives phantom current or the fiber optic insertion key.
The OmniHawk™ installation test feature warns the installer that an initiator
has been connected to both the fiber optic interface and to the copper inter-
face. Since it doesn’t make sense to connect two ring out (RO) trunk lines
together, the power / error LED warns of this condition by lighting red.
8
5
Download from Www.Somanuals.com. All Manuals Search And Download.
RUN-TIME ACTIVITY & ERROR MONITORING
SITE REQUIREMENTS
During normal operation the fiber optic and copper ready LEDs provide
continuous diagnostic information. These LEDs detect and display token
ring activity.
A power outlet should be available within 5 ft. of the unit. The following
power supply modules are required for the following power outlets:
The insert status LED informs the user of the insert status of the fiber optic
and copper media. This LED lights green when both the active signaling
fiber optic and copper devices have successfully reached insertion.
MODEL
3900
POWER OUTLET
110 Volt - 60 Hz
220 Volt - 50 Hz
110 Volt - 60 Hz
220 Volt - 50 Hz
3900-2
3910
The insert status LED flashes when the OmniHawk™ has received phan-
tom current on its copper side but has not yet achieved insertion on its fiber
optic side, or conversely, when the unit has received the fiber optic key on
its fiber side but has not yet sensed a phantom current echoer on its copper
side.
3910-2
NORMAL CONFIGURATION
a. Attach the workstation or hub with the appropriate cable to the
OmniHawk™.
When the OmniHawk™ connects to passive devices, the insert status LED
will always be off.
b. Plug the external power supply into the appropriate AC wall outlet.
c. Plug the power jack into the OmniHawk™ power connector.
f. The LEDs will flash during their self test, then settle according to the
current connection status.
UNPACKING
a. Visual Inspection - before unpacking, a visual inspection should be con-
ducted in order to detect any physical damage to the equipment. Any
evidence of damage should be noted and reported immediately.
Refer to the APPLICATIONS section for useful application information.
b. Unpacking - place shipping container on a flat surface, cut straps or
tape, open top. Take out each item carefully and place securely on a
clean flat surface. Return all packing material into container (foam, boxes
etc.), close and store away for future re-use.
ALTERNATE POWER SOURCE
Some Token Ring network interface cards supply power via the DB-9 con-
nector. Compatible network interface cards supply +5V on pin 3 and ground
on pins 2, 4, 7, and 8. When power from the network interface card is avail-
able, the OmniHawk™ will use that power and the external power supply
may be disconnected.
c. Inspection - Inspect each item for any apparent damage, any evidence
of damage should be noted and reported immediately.
d. Content - Review the content; the following items should be included:
•
•
•
OmniHawk™ module (1)
power supply module
User’s Manual (the document you are now reading)
INSTALLATION TEST CONFIGURATIONS
The OmniHawk™ supports the following media test configuration.
Loopback Media Test
Please note any missing items or discrepancies and report them imme-
diately.
To test the integrity of fiber optic media connect the fiber optic patch cable
in a loopback fashion (i.e., one end in the transmit port and the other in the
receive port). If the fiber is unbroken, the OmniHawk™ fiber ready LED will
illuminate green. If the fiber is partially or completely broken, the LED will be
off.
6
7
Download from Www.Somanuals.com. All Manuals Search And Download.
|