NuTone Ventilation Hood 8663RF User Manual

®
READ & SAVE THESE INSTRUCTIONS!  
INSTALLATION INSTRUCTIONS  
Bathroom Exhaust  
Fan/Fluorescent  
Light Combination  
9"  
9"  
Wiring  
Knockouts  
6"  
Housing  
Slots  
MODEL: 8663RF  
Suitable for use in shower or tub enclosure when used  
with GFCI protected branch circuit.  
Scroll  
Power/Blower  
Unit  
The exhaust fan consists of the housing, power unit/blower  
assembly (motor, wheel, mounting plate,) grille/lens assembly,  
reflector/lamp plug assembly (lamps not furnished,) and duct collar.  
• WARNING: To reduce the risk of shock, do not use this fan with  
any solid-state speed control device.  
Acceptable for use over tub or shower when installed on a GFCI  
protected branch circuit.  
Not for use in kitchens.  
Do not install in a ceiling insulated to a value greater than R-40.  
Wing Nut  
Reflector  
Assembly  
IMPORTANT SAFETY INSTRUCTIONS  
Mounting  
Springs (2)  
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC  
SHOCK, OR INJURY TO PERSONS, OBSERVE THE  
FOLLOWING:  
A. Use this unit only in the manner intended by the manufacturer.  
If you have questions, contact the manufacturer.  
B. Before servicing or cleaning unit, switch power off at Service Panel  
and lock Service Panel to prevent power from being switched on  
accidentally.  
Grille/Lens  
Assembly  
When the service disconnecting means cannot be locked,  
securely fasten a prominent warning device, such as a tag, to the  
service panel.  
CAUTION:  
For general ventilating use only. Do not use to exhaust  
hazardous or explosive materials and vapors.  
1
/
8
14 " DIA.  
FIGURE 1  
INSTALLATION INSTRUCTIONS  
FOR BEST RESULTS  
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC  
SHOCK, OR INJURY TO PERSONS, OBSERVE THE  
FOLLOWING:  
A. Installation work and electrical wiring must be done by qualified  
person(s) in accordance with all applicable codes and standards,  
including fire-rated construction.  
B. Sufficient air is needed for proper combustion and exhausting of  
gases through the flue (chimney) of fuel burning equipment to  
prevent back drafting. Follow the heating equipment  
manufacturer's guideline and safety standards such as those  
published by the National Fire Protection Association (NFPA), and  
the American Society for Heating, Refrigeration and Air  
Conditioning Engineers (ASHRAE), and the local code authorities.  
C. When cutting or drilling into wall or ceiling, do not damage  
electrical wiring and other hidden utilities.  
When installing the Exhaust Fan/Light in a new construction site,  
install housing during the rough-in construction of the building. The  
blower unit, reflector and grille should be installed after the finished  
ceiling is in place.  
PLANNING DUCTWORK AND WIRING  
DUCTWORK  
1. Use 4" round duct.  
2. Plan duct run from discharge opening of fan to the outside. For  
best fan performance, make duct run as short as possible and use  
minimum number of elbows.  
3. Use optional NuTone ducting accessories as needed.  
WIRING  
D. Ducted fans must always be vented to the outdoors.  
E. If this unit is to be installed over a tub or shower, it must be marked  
as appropriate for the application.  
F. NEVER place a switch where it can be reached from a tub or  
shower.  
Plan to run 120vAC house wiring (with ground) from power source,  
through wall switch, to junction box in housing. For separate control of  
fan and light use an optional NuTone switch.  
IMPORTANT: Use wire suitable for 90oC.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COMPLETING INSTALLATION  
11-1/2"  
1. Insert lamp plug into junction box receptacle and secure reflector  
assembly to motor frame with wing nut provided.  
2. Insert lamp (26 watt compact fluorescent - NEMA Type  
CFQ26W/G24D) into the socket.  
5-3/4"  
NOTE: Lamp must be purchased separately.  
3. Insert the grille assembly's mounting springs into the slots on both  
sides of the housing by squeezing the springs together.  
4. Press grille assembly firmly into place against the ceiling.  
2"  
CLEANING AND RELAMPING  
1. Pull grille assembly away from ceiling.  
2. Squeezing the grille assembly's mounting springs together,  
remove grille assembly from housing to expose socket for  
relamping.  
4"  
9-1/8"-10"  
3. Clean grille and lens of assembly using a mild soap and water  
solution.  
4. Replace grille assembly flat against ceiling after cleaning or  
relamping.  
Joist  
FIGURE 6  
INSTALLATION IN EXISTING CONSTRUCTION  
PLANNING  
Review INSTALLATION IN A NEW CONSTRUCTION SITEand  
follow all instructions which apply to your installation.  
LOCATION: Locate fan between ceiling joists.  
WIRING AND DUCTING: Plan ducting and wiring BEFORE  
proceeding with installation. Refer to Figures 4 and 5 for wiring and  
Figure 3 for ducting.  
4" Flexible  
Duct  
CAUTION: Check area above planned location to be sure that:  
1. Ducting can be installed or that area is sufficient for proper  
venting.  
2. Wiring can be run to the planned location.  
3. No wiring or other obstruction might interfere with installation.  
INSTALLATION  
120vAC  
House Wiring  
1. The fan must be mounted between ceiling joists. Decide where  
you want to locate the fan, and then determine where the nearest  
joists are.  
2. Locate the joists. Drill a starter hole in the ceiling between the  
joists.  
Duct  
Collar  
3. To exactly locate the edge of joist, saw a line from hole to joist.  
4. Refer to page 1. Remove power/blower unit from housing.  
5. Use the housing pan as a template to mark cutout: place pan  
centered between joist and trace around pan.  
6. Make cutout along outside of marked line.  
7. Refer to Figure 6. Install 2 x 4 cleats to both ceiling joists. In  
some cases it may be necessary to use more than a single cleat  
on one side. The distance between cleats must be at least 91/8"  
but not more than 10".  
Mounting  
Holes  
Wiring  
Knockout  
Bend  
Mounting  
Tabs  
Flush To  
Side of  
Housing  
8. Remove side wiring knockout and insert and secure an approved  
box connector into the wiring entrance hole.  
9. Use pliers to bend both mounting tabs as flush as possible to the  
side of the housing.  
FIGURE 7  
10. Install duct collar.  
11. String wiring through box connector and connect 4" flexible duct  
to duct collar.  
12. Carefully push ductwork and wiring back into cutout. Place  
housing into cutout.  
13. Use wood screws to secure housing to cleats through four holes  
in housing's pan. make sure pan is flush to finished ceiling.  
14. Install Power/Blower Unit and complete installation.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
One Year Limited Warranty  
WARRANTY OWNER: NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period  
of one (1) year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED  
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
During this one year period, NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.  
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, FILTERS, DUCT, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES  
FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident,  
improper maintenance or repair (other than by NuTone), faulty installation or installation contrary to recommended installation instructions.  
The duration of any implied warranty is limited to the one year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty  
lasts, so the above limitation may not apply to you.  
NUTONES OBLIGATION TO REPAIR OR REPLACE, AT NUTONES OPTION, SHALL BE THE PURCHASERS SOLE AND EXCLUSIVE REMEDY UNDER THIS  
WARRANTY. NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH  
PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may  
not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.  
WARRANTY SERVICE:To qualify for warranty service, you must (a) notify NuTone at the address stated below or telephone 1/800-543-8687, (b) give the model  
number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present  
evidence of the original purchase date.  
Date of Installation  
Builder or Installer  
Model No. and Product Description  
IFYOU NEED ASSISTANCE OR SERVICE:  
For the location of your nearest NuTone Independent Authorized Service Center:  
Residents of the contiguous United States Dial Free 1-800-543-8687  
Please be prepared to provide:  
Product model number Date and Proof of purchase The nature of the difficulty  
Residents of Alaska or Hawaii should write to: NuTone Inc. Attn: Department of National Field Service, 4820 Red Bank Road, Cincinnati Ohio 45227-1599.  
Residents of Canada should write to: Broan-NuTone Canada, 1140 Tristar Drive, Mississauga, Ontario, Canada L5T 1H9.  
Rev. 03/2001  
4820 Red Bank Road, Cincinnati, Ohio 45227  
Printed in U.S.A., Rev. 04/2001, Part No. 87588  
Product specifications subject to change without notice.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EFFECTIVE  
DATE  
PRODUCT  
GROUP  
MODEL NUMBER  
8663RF  
PARTS LIST  
DECEMBER  
1997  
FAN  
11  
9
7
8
5
5
6
16  
17  
2
4
15  
13  
3
3
12  
1
4
14  
18  
CURRENT  
REPLACEMENT  
PART NO.  
ORIGINAL  
PART NO.  
MODEL USED ON  
REF.  
PART DESCRIPTION  
1
2
87587  
86933  
32787  
32788  
51919  
63007  
89248  
85936  
85976  
16133  
30652  
82304  
10034  
85970  
89539  
85937  
57000  
44388  
POWER UNIT ASSEMBLY  
MOTOR  
8663RF  
8663RF  
8663RF  
8663RF  
8663RF  
8663RF  
8663RF  
8663RF  
8663RF  
8663RF  
8663RF  
8663RF  
8663RF  
8663RF  
8663RF  
8663RF  
8663RF  
8663RF  
87587-000  
86933-000  
32787-000  
32788-000  
51919-000  
51919-000  
89248-000  
85936-000  
85976-000  
16133-000  
30652-000  
82304-000  
10034-000  
85970-000  
89539-000  
85937-000  
57000-000  
44388-000  
3
MOTOR ISOLATION MOUNT  
GROUND CLIP  
4
5
BLOWER WHEEL  
PUSH NUT  
6
7
REFLECTOR  
8
LAMPHOLDER BRACKET  
LAMPHOLDER, BALLAST&PLUGASSEMBLY  
WING NUT  
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
DUCT ADAPTER ASSEMBLY  
RECEPTACLE - WHITE  
RECEPTACLE - BLACK  
GRILLE ASSEMBLY  
GRILLE  
LENS  
GRILLE SPRING (1)  
HANGER BAR (1)  
NuTone  
Attn: Parts Department  
®
4820 Red Bank Road  
Cincinnati, OH 45227-1599  
Phone: (513) 527-5426  
Fax: (513) 527-5173  
NOTE: Always order by  
current part number  
8663RF I.I.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Multiquip Automobile Parts DCA25SSIU3 User Manual
Multitech Modem MT5634ZBA User Manual
Murphy Switch Annunciators and Magnetic Switches User Manual
Muse electronic DVD Player Model Eleven User Manual
NETGEAR Network Card MA111 v2 User Manual
Nissan Automobile 2009 Altima Sedan User Manual
NuTone Fan QTXN110HL User Manual
Oki Printer PAGE 10I User Manual
Panasonic Laptop CF 52TKGBZ1M User Manual
Panasonic Telephone KX T2365A User Manual