Nortel Networks Switch LKG Nortel ELO GS8MP User Manual

LG-Nortel ELO GS8MP  
(LNGS8MP)  
Gigabit Ethernet Switch  
Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Guide  
Web-Smart PoE Switch  
Layer 2 Workgroup Switch  
with 7 10/100/1000BASE-T (RJ-45) Ports  
and 1 Gigabit Combination (RJ-45/SFP) Port  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LNGS8MP  
January, 2008  
150000052200A  
Issue 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LIMITED WARRANTY  
LG-NORTEL warrants the Products, excluding consumable items to be free from defective  
design attributable to LG-NORTEL, defective material or faulty workmanship and will conform to  
the Specifications for twelve (12) months from the date of Customer acceptance of the Product.  
WARRANTIES EXCLUSIVE: IF AN LG-NORTEL PRODUCT DOES NOT OPERATE AS  
WARRANTED ABOVE, CUSTOMER’S SOLE REMEDY SHALL BE REPAIR OR  
REPLACEMENT OF THE PRODUCT IN QUESTION, AT LG-NORTEL’S OPTION. THE  
FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL  
OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, EITHER IN FACT OR BY  
OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING WARRANTIES OR  
CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. LG-  
NORTEL NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR  
IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION,  
MAINTENANCE OR USE OF ITS PRODUCTS. LG-NORTEL SHALL NOT BE LIABLE UNDER  
THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THE ALLEGED DEFECT  
IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER’S OR ANY THIRD  
PERSON’S MISUSE, NEGLECT, IMPROPER INSTALLATION OR TESTING, UNAUTHORIZED  
ATTEMPTS TO REPAIR, OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED  
USE, OR BY ACCIDENT, FIRE, LIGHTNING, OR OTHER HAZARD.  
LIMITATION OF LIABILITY: IN NO EVENT, WHETHER BASED IN CONTRACT OR TORT  
(INCLUDING NEGLIGENCE), SHALL LG-NORTEL BE LIABLE FOR INCIDENTAL,  
CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY KIND, OR FOR  
LOSS OF REVENUE, LOSS OF BUSINESS, OR OTHER FINANCIAL LOSS ARISING OUT OF  
OR IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE, USE,  
PERFORMANCE, FAILURE, OR INTERRUPTION OF ITS PRODUCTS, EVEN IF LG-NORTEL  
OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH  
DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES  
OR THE LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR CONSUMER  
PRODUCTS, SO THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO YOU.  
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, WHICH MAY VARY FROM STATE  
TO STATE. NOTHING IN THIS WARRANTY SHALL BE TAKEN TO AFFECT YOUR  
STATUTORY RIGHTS.  
* LG-NORTEL will provide warranty service for one year following discontinuance from the active  
LG-NORTEL price list. Under the limited lifetime warranty, internal and external power supplies,  
fans, and cables are covered by a standard one-year warranty from date of purchase.  
LG-NORTEL Co.Ltd.  
GS Tower, 679 Yoksam-dong,  
Kangnam-gu, Seoul, 135-985, Korea  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Compliances and Safety Warnings  
FCC - Class A  
This equipment has been tested and found to comply with the limits for a Class A digital  
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide  
reasonable protection against harmful interference when the equipment is operated in a  
commercial environment. This equipment generates, uses, and can radiate radio  
frequency energy and, if not installed and used in accordance with the instruction manual,  
may cause harmful interference to radio communications. Operation of this equipment in  
a residential area is likely to cause harmful interference in which case the user will be  
required to correct the interference at his own expense.  
You are cautioned that changes or modifications not expressly approved by the party  
responsible for compliance could void your authority to operate the equipment.  
You may use unshielded twisted-pair (UTP) for RJ-45 connections - Category 3 or better  
for 10 Mbps connections, Category 5 or better for 100 Mbps connections, Category 5, 5e,  
or 6 for 1000 Mbps connections. For fiber optic connections, you may use 50/125 or 62.5/  
125 micron multimode fiber or 9/125 micron single-mode fiber.  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
CE Mark Declaration of Conformance for EMI and Safety (EEC)  
This information technology equipment complies with the requirements of the Council  
Directive 89/336/EEC on the Approximation of the laws of the Member States relating to  
Electromagnetic Compatibility and 73/23/EEC for electrical equipment used within certain  
voltage limits and the Amendment Directive 93/68/EEC. For the evaluation of the  
compliance with these Directives, the following standards were applied:  
RFI Emission:  
Limit class A according to EN 55022:1998  
Limit class A for harmonic current emission according to EN 61000-3-2/1995  
Limitation of voltage fluctuation and flicker in low-voltage supply system according to  
EN 61000-3-3/1995  
Immunity:  
Product family standard according to EN 55024:1998  
Electrostatic Discharge according to EN 61000-4-2:1995 (Contact Discharge: ±4 kV,  
Air Discharge: ±8 kV)  
Radio-frequency electromagnetic field according to EN 61000-4-3:1996 (80 - 1000  
MHz with 1 kHz AM 80% Modulation: 3 V/m)  
Electrical fast transient/burst according to EN 61000-4-4:1995 (AC/DC power supply:  
±1 kV, Data/Signal lines: ±0.5 kV)  
Surge immunity test according to EN 61000-4-5:1995  
(AC/DC Line to Line: ±1 kV, AC/DC Line to Earth: ±2 kV)  
Immunity to conducted disturbances, Induced by radio-frequency fields:  
EN 61000-4-6:1996 (0.15 - 80 MHz with  
1 kHz AM 80% Modulation: 3 V/m)  
Power frequency magnetic field immunity test according to EN 61000-4-8:1993 (1 A/m  
at frequency 50 Hz)  
Voltage dips, short interruptions and voltage variations immunity test according to  
EN 61000-4-11:1994 (>95% Reduction @10 ms, 30% Reduction @500 ms, >95%  
Reduction @5000 ms)  
LVD:  
EN 60950-1:2001  
Caution: Do not plug a phone jack connector in the RJ-45 port. This may damage this  
device.  
Attention:Les raccordeurs ne sont pas utilisés pour le système téléphonique!  
Safety Compliance  
Warning: Fiber Optic Port Safety  
When using a fiber optic port, never look at the transmit laser while  
it is powered on. Also, never look directly at the fiber TX port and  
fiber cable ends when they are powered on.  
CLASS I  
LASER DEVICE  
Avertissment: Ports pour fibres optiques - sécurité sur le plan optique  
Ne regardez jamais le laser tant qu'il est sous tension. Ne regardez  
DISPOSITIF LASER  
DE CLASSE I  
jamais directement le port TX (Transmission) à fibres optiques et  
les embouts de câbles à fibres optiques tant qu'ils sont sous  
tension.  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warnhinweis: Faseroptikanschlüsse - Optische Sicherheit  
Niemals ein Übertragungslaser betrachten, während dieses  
eingeschaltet ist. Niemals direkt auf den  
LASERGERÄT  
DER KLASSE I  
Faser-TX-Anschluß und auf die Faserkabelenden schauen,  
während diese eingeschaltet sind.  
Power Cord Safety  
Please read the following safety information carefully before installing this switch:  
Warning: Installation and removal of the unit must be carried out by qualified personnel  
only.  
The unit must be connected to an earthed (grounded) outlet to comply with international  
safety standards.  
Do not connect the unit to an A.C. outlet (power supply) without an earth (ground)  
connection.  
The appliance coupler (the connector to the unit and not the wall plug) must have a  
configuration for mating with an EN 60320/IEC 320 appliance inlet.  
The socket outlet must be near to the unit and easily accessible. You can only remove  
power from the unit by disconnecting the power cord from the outlet.  
This unit operates under SELV (Safety Extra Low Voltage) conditions according to  
IEC 60950. The conditions are only maintained if the equipment to which it is connected  
also operates under SELV conditions.  
France and Peru only  
This unit cannot be powered from IT supplies. If your supplies are of IT type, this unit  
must be powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the  
secondary connection point labelled Neutral, connected directly to earth (ground).  
Impédance à la terre  
Warning: The user should disconnect all Telecommunications Network connectors and all  
Cable Distribution System connectors before disconnecting the power.  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Important! Before making connections, make sure you have the correct cord set. Check  
it (read the label on the cable) against the following:  
Power Cord Set  
U.S.A. and Canada  
The cord set must be UL-approved and CSA certified.  
The minimum specifications for the flexible cord are:  
- No. 18 AWG - not longer than 2 meters, or 16 AWG.  
- Type SV or SJ  
- 3-conductor  
The cord set must have a rated current capacity of at least 10 A  
The attachment plug must be an earth-grounding type with NEMA 5-15P (15 A,  
125 V) or NEMA 6-15P (15 A, 250 V) configuration.  
Denmark  
The supply plug must comply with Section 107-2-D1, Standard DK2-1a or  
DK2-5a.  
Switzerland  
U.K.  
The supply plug must comply with SEV/ASE 1011.  
The supply plug must comply with BS1363 (3-pin 13 A) and be fitted with a 5 A  
fuse which complies with BS1362.  
The mains cord must be <HAR> or <BASEC> marked and be of type  
HO3VVF3GO.75 (minimum).  
Europe  
The supply plug must comply with CEE7/7 (“SCHUKO”).  
The mains cord must be <HAR> or <BASEC> marked and be of type  
HO3VVF3GO.75 (minimum).  
IEC-320 receptacle.  
Veuillez lire à fond l'information de la sécurité suivante avant  
d'installer le Switch:  
AVERTISSEMENT: L’installation et la dépose de ce groupe doivent être confiés à un  
personnel qualifié.  
Ne branchez pas votre appareil sur une prise secteur (alimentation électrique) lorsqu'il  
n'y a pas de connexion de mise à la terre (mise à la masse).  
Vous devez raccorder ce groupe à une sortie mise à la terre (mise à la masse) afin de  
respecter les normes internationales de sécurité.  
Le coupleur d’appareil (le connecteur du groupe et non pas la prise murale) doit  
respecter une configuration qui permet un branchement sur une entrée d’appareil EN  
60320/IEC 320.  
La prise secteur doit se trouver à proximité de l’appareil et son accès doit être facile.  
Vous ne pouvez mettre l’appareil hors circuit qu’en débranchant son cordon électrique  
au niveau de cette prise.  
L’appareil fonctionne à une tension extrêmement basse de sécurité qui est conforme à  
la norme IEC 60950. Ces conditions ne sont maintenues que si l’équipement auquel il  
est raccordé fonctionne dans les mêmes conditions.  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
France et Pérou uniquement:  
Ce groupe ne peut pas être alimenté par un dispositif à impédance à la terre. Si vos  
alimentations sont du type impédance à la terre, ce groupe doit être alimenté par une  
tension de 230 V (2 P+T) par le biais d’un transformateur d’isolement à rapport 1:1, avec  
un point secondaire de connexion portant l’appellation Neutre et avec raccordement  
direct à la terre (masse).  
Cordon électrique - Il doit être agréé dans le pays d’utilisation  
Etats-Unis et Canada:  
Le cordon doit avoir reçu l’homologation des UL et un certificat de la CSA.  
Les spécifications minimales pour un cable flexible sont AWG No. 18, ouAWG  
No. 16 pour un cable de longueur inférieure  
- type SV ou SJ  
- 3 conducteurs  
à
2 métres.  
Le cordon doit être en mesure d’acheminer un courant nominal d’au moins 10  
A.  
La prise femelle de branchement doit être du type à mise à la terre (mise à la  
masse) et respecter la configuration NEMA 5-15P (15 A, 125 V) ou NEMA  
6-15P (15 A, 250 V).  
Danemark:  
La prise mâle d’alimentation doit respecter la section 107-2 D1 de la norme  
DK2 1a ou DK2 5a.  
Suisse:  
Europe  
La prise mâle d’alimentation doit respecter la norme SEV/ASE 1011.  
La prise secteur doit être conforme aux normes CEE 7/7 (“SCHUKO”)  
LE cordon secteur doit porter la mention <HAR> ou <BASEC> et doit être de  
type HO3VVF3GO.75 (minimum).  
Bitte unbedingt vor dem Einbauen des Switches die folgenden  
Sicherheitsanweisungen durchlesen:  
WARNUNG: Die Installation und der Ausbau des Geräts darf nur durch Fachpersonal  
erfolgen.  
Das Gerät sollte nicht an eine ungeerdete Wechselstromsteckdose angeschlossen  
werden.  
Das Gerät muß an eine geerdete Steckdose angeschlossen werden, welche die  
internationalen Sicherheitsnormen erfüllt.  
Der Gerätestecker (der Anschluß an das Gerät, nicht der Wandsteckdosenstecker) muß  
einen gemäß EN 60320/IEC 320 konfigurierten Geräteeingang haben.  
Die Netzsteckdose muß in der Nähe des Geräts und leicht zugänglich sein. Die  
Stromversorgung des Geräts kann nur durch Herausziehen des Gerätenetzkabels aus  
der Netzsteckdose unterbrochen werden.  
Der Betrieb dieses Geräts erfolgt unter den SELV-Bedingungen  
(Sicherheitskleinstspannung) gemäß IEC 60950. Diese Bedingungen sind nur gegeben,  
wenn auch die an das Gerät angeschlossenen Geräte unter SELV-Bedingungen  
betrieben werden.  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stromkabel. Dies muss von dem Land, in dem es benutzt wird geprüft werden:  
Schweiz  
Europe  
Dieser Stromstecker muß die SEV/ASE 1011Bestimmungen einhalten.  
Das Netzkabel muß vom Typ HO3VVF3GO.75 (Mindestanforderung) sein und  
die Aufschrift <HAR> oder <BASEC> tragen.  
Der Netzstecker muß die Norm CEE 7/7 erfüllen (”SCHUKO”).  
Warnings and Cautionary Messages  
Warning: This product does not contain any serviceable user parts.  
Warning: Installation and removal of the unit must be carried out by qualified  
personnel only.  
Warning: When connecting this device to a power outlet, connect the field  
ground lead on the tri-pole power plug to a valid earth ground line to  
prevent electrical hazards.  
Warning: This switch uses lasers to transmit signals over fiber optic cable. The  
lasers are compliant with the requirements of a Class 1 Laser  
Product and are inherently eye safe in normal operation. However,  
you should never look directly at a transmit port when it is powered  
on.  
Caution:  
Wear an anti-static wrist strap or take other suitable measures to  
prevent electrostatic discharge when handling this equipment.  
Caution:  
Do not plug a phone jack connector in the RJ-45 port. This may  
damage this device. Les raccordeurs ne sont pas utilisé pour le  
système téléphonique!  
Caution:  
Use only twisted-pair cables with RJ-45 connectors that conform to  
FCC standards.  
Warnings (in German)  
Achtung: Dieses Produkt enthält keine Teile, die eine Wartung vom Benutzer  
benötigen.  
Achtung: Installation und Deinstallation des Gerätes müssen von qualifiziertem  
Servicepersonal durchgeführt werden.  
Achtung: Wenn das Gerät an eine Steckdose angeschlossen wird, muß der  
Masseanschluß am dreipoligen Netzstecker mit Schutzerde  
verbunden werden, um elektrische Gefahren zu vermeiden.  
Achtung: Dieses Gerät nutzt Laser zur Signalübertragung über Glasfasern. Die  
Laser entsprechen den Anforderungen an eine Lasereinrichtung der  
Klasse 1 und sind durch ihre Bauart im normalen Betrieb sicher für die  
Augen. Trotzdem sollte niemals direkt in den einen  
Übertragungskanal geblickt werden, wenn er eingeschaltet ist.  
vi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Environmental Statement  
The manufacturer of this product endeavours to sustain an environmentally-friendly policy  
throughout the entire production process. This is achieved through the following means:  
Adherence to national legislation and regulations on environmental production  
standards.  
Conservation of operational resources.  
Waste reduction and safe disposal of all harmful un-recyclable by-products.  
Recycling of all reusable waste content.  
Design of products to maximize recyclables at the end of the product’s life span.  
Continual monitoring of safety standards.  
End of Product Life Span  
This product is manufactured in such a way as to allow for the recovery and disposal of all  
included electrical components once the product has reached the end of its life.  
Manufacturing Materials  
There are no hazardous nor ozone-depleting materials in this product.  
Documentation  
All printed documentation for this product uses biodegradable paper that originates from  
sustained and managed forests. The inks used in the printing process are non-toxic.  
Purpose  
This guide details the hardware features of this switch, including Its physical and  
performance-related characteristics, and how to install the switch.  
Audience  
This guide is for system administrators with a working knowledge of network  
management. You should be familiar with switching and networking concepts.  
Zielgruppe Dieser Anleitung ist fuer Systemadministratoren mit Erfahrung im  
Netzwerkmangement. Sie sollten mit Switch- und Netzwerkkonzepten vertraut sein.  
Related Publications  
The following publication gives specific information on how to operate and use the  
management functions of this switch:  
The LNGS8MP Management Guide  
Also, as part of both switches firmware, there is an online web-based help that describes  
all management related features.  
vii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
viii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1: Introduction  
Overview  
The LNGS8MP is an intelligent Layer 2 switch with eight 10/100/1000BASE-T ports,  
*
one of which is a Gigabit combination port that is shared with an SFP transceiver  
slot.  
The switch’s eight 10/100/1000 Mbps ports support the IEEE 802.3af  
Power-over-Ethernet (PoE) standard that enables DC power to be supplied to  
attached devices over the data wire pairs in the connecting Ethernet cable.  
10/100/1000 Mbps RJ-45 Ports  
Port Status Indicators  
Status  
1
2
3
4
5
6
7
8
1000BASE-T/SFP Port  
Figure 1-1 Front Panel  
100-240V ~50-60Hz 1.5A  
Power Socket  
Figure 1-2 Rear Panel  
*
If an SFP transceiver is plugged in, the corresponding RJ-45 port is disabled.  
1-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Introduction  
1
Switch Architecture  
The switch employs a wire-speed, non-blocking switching fabric. This permits  
simultaneous wire-speed transport of multiple packets at low latency on all ports.  
The switch also features full-duplex capability on all ports, which effectively doubles  
the bandwidth of each connection.  
The switch uses store-and-forward switching to ensure maximum data integrity. With  
store-and-forward switching, the entire packet must be received into a buffer and  
checked for validity before being forwarded. This prevents errors from being  
propagated throughout the network.  
Power-over-Ethernet Capability  
The switch’s eight 10/100/1000 Mbps ports support the IEEE 802.3af  
Power-over-Ethernet (PoE) standard that enables DC power to be supplied to  
attached devices using wires in the connecting Ethernet cable. Any 802.3af  
compliant device attached to a port can directly draw power from the switch over the  
Ethernet cable without requiring its own separate power source. This capability gives  
network administrators centralized power control for devices such as IP phones and  
wireless access points, which translates into greater network availability.  
For each attached 802.3af-compliant device, the switch automatically senses the  
load and dynamically supplies the required power. Independent overload and  
short-circuit protection for each port allows the switch to automatically shut down a  
port’s power when limits are exceeded.  
Port 1 on the switch can provide up to 25 W of power to an attached device at the  
standard 48 DC voltage. Ports 2-8 can provide up to 15.4 W of power.  
Network Management Options  
The switch contains a comprehensive array of LEDs for “at-a-glance” monitoring of  
network and port status. They also include a management agent that allows you to  
configure or monitor the switch using its embedded management software.  
For a detailed description of switch’s advanced features, refer to the Management  
Guide.  
1-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Description of Hardware  
1
Description of Hardware  
10/100/1000BASE-T Ports  
The switch contains eight RJ-45 ports that operate at 10 Mbps or 100 Mbps, half or  
full duplex, or at 1000 Mbps, full duplex. Because all ports on the switch support  
automatic MDI/MDI-X operation, you can use straight-through cables for all network  
connections to PCs or servers, or to other switches or hubs. (See “1000BASE-T Pin  
Each of these ports support auto-negotiation, so the optimum transmission mode  
(half or full duplex), and data rate (10, 100, or 1000 Mbps) can be selected  
automatically. If a device connected to one of these ports does not support  
auto-negotiation, the communication mode of that port can be configured manually.  
SFP Slot  
The Small Form Factor Pluggable (SFP) transceiver slot is shared with RJ-45 Port 8.  
If an SFP transceiver (purchased separately) is installed in the slot and has a valid  
link on its port, the associated RJ-45 port is disabled and cannot be used.  
Port and Power Status LEDs  
The switch includes a display panel for key system and port indications that simplify  
installation and network troubleshooting. The LEDs, which are located on the front  
panel for easy viewing, are shown below and described in the following tables.  
1
Port Status LEDs  
Power Status LED  
Figure 1-3 Port and Power LEDs  
1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
Introduction  
1
Table 1-1 Port Status LEDs  
Condition Status  
LED  
Fast Ethernet Ports (Ports 1-8)  
Link/Act  
(Link/Activity)  
On/Flashing Green Port has a valid 1000Mbps link. Flashing indicates  
network activity  
On/Flashing Amber Port has a valid 10/100Mbps link. Flashing indicates  
network activity  
Off  
No link.  
PoE  
On Amber  
Off  
A PoE device is connected.  
No PoE device connected.  
SFP transceiver installed correctly.  
No SFP present.  
(SFP) Status  
On Green  
Off  
Table 1-2 Power Status LED  
LED  
Condition  
Status  
Power  
Green  
Off  
Internal power is operating normally.  
Power off.  
Power Supply Socket  
The power socket is located on the rear panel of the switch. The standard power  
socket is for the AC power cord.  
100-240V ~50-60Hz 1.5A  
Figure 1-4 Power Supply Socket  
1-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Features and Benefits  
1
Features and Benefits  
Connectivity  
8 10/100/1000 Mbps ports for easy Gigabit Ethernet integration and for protection  
of your investment in legacy LAN equipment.  
All RJ-45 ports support IEEE 802.3af standard Power-over-Ethernet  
Auto-negotiation enables each RJ-45 port to automatically select the optimum  
communication mode (half or full duplex) if this feature is supported by the  
attached device; otherwise the port can be configured manually.  
RJ-45 ports support auto MDI/MDI-X pinout selection.  
Unshielded (UTP) cable supported on all RJ-45 ports: Category 3 or better for  
10 Mbps connections, Category 5 or better for 100 Mbps connections, and  
Category 5, 5e, 6 or better for 1000 Mbps connections.  
IEEE 802.3-2005 Ethernet, Fast Ethernet, and Gigabit Ethernet.  
Expandability  
One Small Form Factor Pluggable (SFP) transceiver slot (shared with Port 8)  
Supports 1000BASE-SX, 1000BASE-LX and 1000BASE-LH SFP transceivers.  
Performance  
Transparent bridging.  
Provides store-and-forward switching  
Jumbo-Frame up to 9.6 Kbytes  
Supports flow control  
Broadcast storm control  
Management  
“At-a-glance” LEDs for easy troubleshooting.  
Network management agent  
Manages switch in-band  
Supports web-based interface  
1-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
Introduction  
1
1-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Network Planning  
Introduction to Switching  
A network switch allows simultaneous transmission of multiple packets via  
non-crossbar switching. This means that it can partition a network more efficiently  
than bridges or routers. The switch has, therefore, been recognized as one of the  
most important building blocks for today’s networking technology.  
When performance bottlenecks are caused by congestion at the network access  
point (such as the network card for a high-volume file server), the device  
experiencing congestion (server, power user or hub) can be attached directly to a  
switched port. And, by using full-duplex mode, the bandwidth of the dedicated  
segment can be doubled to maximize throughput.  
When networks are based on repeater (hub) technology, the distance between end  
stations is limited by a maximum hop count. However, a switch turns the hop count  
back to zero. So subdividing the network into smaller and more manageable  
segments, and linking them to the larger network by means of a switch, removes this  
limitation.  
A switch can be easily configured in any Ethernet, Fast Ethernet, or Gigabit  
Ethernet, network to significantly boost bandwidth while using conventional cabling  
and network cards.  
2-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Network Planning  
2
Application Examples  
The switch is not only designed to segment your network, but also to provide a wide  
range of options in setting up network connections. Some typical applications are  
described below.  
Supplying PoE  
The switch is an excellent choice for supplying power to connected PoE devices  
such as web cameras, IP telephones or access points. You can easily connect a  
PoE device to a switch port and allow power to be supplied over the connecting  
cable. Each of the eight ports on the switch can provide power to a connected  
device.  
In the figure below, the switch is supplying power to three PoE devices. It is also  
providing dedicated 100 Mbps full-duplex data connections to the devices. In  
addition, other non-PoE devices can be connected to the switch.  
Status  
1
2
3
4
5
6
7
8
Power-over-Ethernet Devices  
Access Point  
IP Telephone  
Web Camera  
Figure 2-1 PoE Connections  
Collapsed Backbone  
The switch is an excellent choice for mixed Ethernet, Fast Ethernet, and Gigabit  
Ethernet installations where significant growth is expected in the near future. In a  
basic stand-alone configuration, it can provide direct full-duplex connections for up  
to eight workstations or servers. You can easily build on this basic configuration,  
adding direct full-duplex connections to workstations or servers. When the time  
comes for further expansion, just connect to another hub or switch using one of the  
Gigabit Ethernet ports built into the front panel, a Gigabit Ethernet port on a plug-in  
SFP transceiver.  
In the figure below, the 8-port switch is operating as a collapsed backbone for a  
small LAN. It is providing dedicated 10 Mbps full-duplex connections to  
workstations, 100 Mbps full-duplex connections to power users, and 1 Gbps  
full-duplex connections to servers. In addition, connected IP phones and wireless  
2-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Application Examples  
2
access points are receiving PoE power from the switch.  
Status  
1
2
3
4
5
6
7
8
...  
Power-over-Ethernet Devices  
10/100 Mbps  
Full Duplex  
Servers  
1000 Mbps  
Full Duplex  
...  
Workstations  
100 Mbps  
Full Duplex  
Standard LAN  
PoE  
Network Segment  
100 Mbps  
Full Duplex  
Figure 2-2 Collapsed Backbone  
Meeting Room  
With eight 1000 Mbps parallel bridging ports (i.e., eight distinct collision domains),  
this switch can function as an efficient bridged node that is ideal for a meeting room  
environment. Zero noise makes the switch inobtrusive for such a setting.  
In the figure below, the LNGS8MP is connected to a central wiring closet via a  
1000BASE-SX connection. The 1000BASE-T RJ-45 ports on the switch are  
providing 10/100 Mbps full-duplex connections for PCs and notebooks, as well as  
providing power and connectivity for PoE devices, such as IP telephones and web  
cameras.  
Wiring Closet  
1000BASE-SX SMF  
Meeting Room PoE Switch  
Server Farm  
Status  
1
2
3
4
5
6
7
8
10/100 Mbps Segments  
Computer  
Web Camera IP Telephone  
Standard LAN  
PoE  
Figure 2-3 Meeting Room  
2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Network Planning  
2
Making VLAN Connections  
The switch supports VLANs that can be used to organize any group of network  
nodes into separate broadcast domains. VLANs confine broadcast traffic to the  
originating group, and can eliminate broadcast storms in large networks. This  
provides a more secure and cleaner network environment.  
VLANs can be based on untagged port groups, or traffic can be explicitly tagged to  
identify the VLAN group to which it belongs. Untagged VLANs can be used for small  
networks attached to a single switch. However, tagged VLANs should be used for  
larger networks, and all the VLANs assigned to the inter-switch links.  
R&D  
VLAN 1  
Status  
1
2
3
4
5
6
7
8
Tagged  
Ports  
Untagged Ports  
Tagged Port  
VLAN  
aware  
switch  
VLAN  
unaware  
switch  
Finance  
VLAN 2  
Testing  
R&D  
Marketing  
Finance  
Testing  
VLAN 3  
VLAN 4  
VLAN 1  
VLAN 2  
VLAN 3  
Figure 2-4 Making VLAN Connections  
Note: When connecting to a switch that does not support IEEE 802.1Q VLAN tags, use  
untagged ports.  
2-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Application Notes  
2
Application Notes  
1. Full-duplex operation only applies to point-to-point access (such as when a  
switch is attached to a workstation, server or another switch). When the switch  
is connected to a hub, both devices must operate in half-duplex mode.  
2. For network applications that require routing between dissimilar network types,  
you can attach the switch directly to a multi-protocol router.  
3. As a general rule, the length of fiber optic cable for a single switched link should  
not exceed:  
•1000BASE-SX: 550 m (1805 ft) for multimode fiber  
•1000BASE-LX: 5 km (3.1 miles) for single-mode fiber  
•1000BASE-LH: 70 km (43 miles) for single-mode fiber  
However, power budget constraints must also be considered when calculating  
the maximum cable length for your specific environment.  
2-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Network Planning  
2
2-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Installing the Switch  
Selecting a Site  
switch units can be mounted in a standard 19-inch equipment rack or on a flat  
surface. Be sure to follow the guidelines below when choosing a location.  
The site should:  
be at the center of all the devices you want to link and near a power outlet.  
be able to maintain its temperature within 0 to 45 °C (32 to 113 °F) and its  
humidity within 10% to 90%, non-condensing  
provide adequate space (approximately five centimeters or two inches) on all  
sides for proper air flow  
be accessible for installing, cabling and maintaining the devices  
allow the status LEDs to be clearly visible  
Make sure twisted-pair cable is always routed away from power lines, fluorescent  
lighting fixtures and other sources of electrical interference, such as radios and  
transmitters.  
Make sure that the unit is connected to a separate grounded power outlet that  
provides 100 to 240 VAC, 50 to 60 Hz, is within 2 m (6.6 feet) of each device and  
is powered from an independent circuit breaker. As with any equipment, using a  
filter or surge suppressor is recommended.  
Ethernet Cabling  
To ensure proper operation when installing the switches into a network, make sure  
that the current cables are suitable for 10BASE-T, 100BASE-TX or 1000BASE-T  
operation. Check the following criteria against the current installation of your  
network:  
Cable type: Unshielded twisted pair (UTP) or shielded twisted pair (STP) cables  
with RJ-45 connectors; Category 3 or better for 10BASE-T, Category 5 or better  
for 100BASE-TX, and Category 5, 5e or 6 for 1000BASE-T.  
Protection from radio frequency interference emissions  
Electrical surge suppression  
Separation of electrical wires (switch related or other) and electromagnetic fields  
from data based network wiring  
Safe connections with no damaged cables, connectors or shields  
3-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                   
Installing the Switch  
3
RJ-45 Connector  
Figure 3-1 RJ-45 Connections  
Equipment Checklist  
After unpacking the switch unit, check the contents to be sure you have received all  
the components. Then, before beginning the installation, be sure you have all other  
necessary installation equipment.  
Package Contents  
LNGS8MP switch  
Four adhesive foot pads  
Bracket Mounting Kit containing two brackets and eight screws for attaching the  
brackets to the switch  
Power cord—either US, Continental Europe or UK  
This Installation Guide  
Management Guide CD  
Optional Rack-Mounting Equipment  
If you plan to rack-mount the switches, be sure to have the following equipment  
available:  
Four mounting screws for each device you plan to install in a rack—these are not  
included  
A screwdriver (Phillips or flathead, depending on the type of screws used)  
Mounting  
A switch unit can be mounted in a standard 19-inch equipment rack or on a desktop  
or shelf. Mounting instructions for each type of site follow.  
3-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
Mounting  
3
Rack Mounting  
Before rack mounting the switch, pay particular attention to the following factors:  
Temperature: Since the temperature within a rack assembly may be higher than  
the ambient room temperature, check that the rack-environment temperature is  
within the specified operating temperature range (See page C-1.).  
Mechanical Loading: Do not place any equipment on top of a rack-mounted unit.  
Circuit Overloading: Be sure that the supply circuit to the rack assembly is not  
overloaded.  
Grounding: Rack-mounted equipment should be properly grounded. Particular  
attention should be given to supply connections other than direct connections to  
the mains.  
To rack-mount devices:  
1. Attach the brackets to the device using the screws provided in the Bracket  
Mounting Kit.  
Figure 3-2 Attaching the Brackets  
3-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Installing the Switch  
3
2. Mount the device in the rack, using four rack-mounting screws (not provided).  
Figure 3-3 Installing the Switch in a Rack  
3. If installing a single switch only, turn to “Connecting to a Power Source” at the  
end of this chapter.  
4. If installing multiple switches, mount them in the rack, one below the other, in  
any order.  
Desktop or Shelf Mounting  
1. Attach the four adhesive feet to the bottom of the first switch.  
8
S t a t u s  
7
6
5
4
3
1
2
Figure 3-4 Attaching the Adhesive Feet  
3-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Installing an Optional SFP Transceiver  
3
2. Set the device on a flat surface near an AC power source, making sure there  
are at least two inches of space on all sides for proper air flow.  
3. If installing a single switch only, go to “Connecting to a Power Source” at the  
end of this chapter.  
4. If installing multiple switches, attach four adhesive feet to each one. Place each  
device squarely on top of the one below, in any order.  
Installing an Optional SFP Transceiver  
Figure 3-5 Inserting an SFP Transceiver into a Slot  
The switch supports the following optional transceivers:  
1000BASE-SX  
1000BASE-LX  
1000BASE-LH  
To install an SFP transceiver, do the following:  
1. Consider network and cabling requirements to select an appropriate transceiver  
2. Insert the transceiver with the optical connector facing outward and the slot  
connector facing down. Note that SFP transceivers are keyed so they can only  
be installed in one orientation.  
3. Slide the transceiver into the slot until it clicks into place.  
Note: SFP transceivers are hot-swappable. The switch does not need to be powered off  
before installing or removing a transceiver. However, always first disconnect the  
network cable before removing a transceiver.  
Note: SFP transceivers are not provided in the switch package.  
3-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installing the Switch  
3
Connecting to a Power Source  
To connect a device to a power source:  
1. Insert the power cable plug directly into the socket located at the back of the  
device.  
100-240V ~50-60Hz 1.5A  
Figure 3-6 Power Socket  
2. Plug the other end of the cable into a grounded, three-pin, AC power source.  
Note: For international use, you may need to change the AC line cord. You must use  
a line cord set that has been approved for the socket type in your country.  
3. Check the front-panel LEDs as the device is powered on to be sure the Power  
LED is on. If not, check that the power cable is correctly plugged in.  
3-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Chapter 4: Making Network Connections  
Connecting Network Devices  
The switch units are designed to interconnect multiple segments (or collision  
domains). It can be connected to network cards in PCs and servers, as well as to  
hubs, switches or routers. It may also be connected to devices using optional SFP  
transceivers.  
If 802.3af-compliant PoE devices are connected to the switch’s 10/100 Mbps ports,  
the switch automatically supplies the required power.  
Twisted-Pair Devices  
Each device requires an unshielded twisted-pair (UTP) cable with RJ-45 connectors  
at both ends. Use Category 5, 5e or 6 cable for 1000BASE-T connections, Category  
5 or better for 100BASE-TX connections, and Category 3 or better for 10BASE-T  
connections.  
Power-over-Ethernet Connections  
The switch automatically detects an 802.3af-compliant device by its authenticated  
PoE signature and senses its required load before turning on DC power to the port.  
This detection mechanism prevents damage to other network equipment that is not  
802.3af complaint.  
Note: Power-over-Ethernet connections work with all existing Category 3, 4, 5, 5e or 6  
network cabling, including patch cables and patch-panels, outlets, and other  
connecting hardware, without requiring modification.  
The switch delivers power to a device using wire pairs in the connecting Ethernet  
cable. The switch can provide up to 15.4 W of power continuously on each 10/100  
Mbps port. However, taking into account some power loss over the cable run, the  
amount of power that can be delivered to a terminal device is 12.95 W. If a device  
draws more than 15.4 W, from a port, an overload condition occurs and the port  
turns off the power.  
The switch controls the power and data on a port independently. Power can be  
requested from a device that already has a data link to the switch. Also, the switch  
can supply power to a device even if the port’s data connection has been disabled.  
The power on a port is continuously monitored by the switch and it will be turned off  
as soon as a device connection is removed.  
4-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Making Network Connections  
4
Cabling Guidelines  
The RJ-45 ports on the switch support automatic MDI/MDI-X pinout configuration, so  
you can use standard straight-through twisted-pair cables to connect to any other  
network device (PCs, servers, switches, routers, or hubs).  
See Appendix B: for further information on cabling.  
Caution: Do not plug a phone jack connector into an RJ-45 port. This will  
damage the switch. Use only twisted-pair cables with RJ-45 connectors that  
conform to FCC standards.  
Connecting to PCs, Servers, Hubs and Switches  
1. Attach one end of a twisted-pair cable segment to the device’s RJ-45  
connector.  
Figure 4-1 Making Twisted-Pair Connections  
2. If the device is a PC card and the switch is in the wiring closet, attach the other  
end of the cable segment to a modular wall outlet that is connected to the wiring  
closet. (See “Network Wiring Connections” on page 4-3.) Otherwise, attach the  
other end to an available port on the switch.  
Make sure each twisted pair cable does not exceed 100 meters (328 ft) in  
length.  
3. As each connection is made, the Link LED (on the switch) corresponding to  
each port turns on to indicate that the connection is valid.  
4-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Twisted-Pair Devices  
4
Network Wiring Connections  
Today, the punch-down block is an integral part of many of the newer equipment  
racks. It is actually part of the patch panel. Instructions for making connections in the  
wiring closet with this type of equipment follows.  
1. Attach one end of a patch cable to an available port on the switch, and the other  
end to the patch panel.  
2. If not already in place, attach one end of a cable segment to the back of the  
patch panel where the punch-down block is located, and the other end to a  
modular wall outlet.  
3. Label the cables to simplify future troubleshooting. See “Cable Labeling and  
Equipment Rack  
(side view)  
Network Switch  
w
h
0
/
4
L
7
Status  
1
2
3
4
5
6
7
8
454
Punch-Down Block  
Patch Panel  
Wall  
Figure 4-2 Wiring Closet Connections  
4-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Making Network Connections  
4
Fiber Optic SFP Devices  
An optional Gigabit SFP transceiver (1000BASE-SX, 1000BASE-LX or  
1000BASE-LH) can be used for a backbone connection between switches, or for  
connecting to a high-speed server.  
Each single-mode fiber port requires 9/125 micron single-mode fiber optic cable with  
an LC connector at both ends. Each multimode fiber optic port requires 50/125 or  
62.5/125 micron multimode fiber optic cabling with an LC connector at both ends.  
Warning: The switch use lasers to transmit signals over fiber optic cable. The lasers are  
compliant with the requirements of a Class 1 Laser Product and are inherently  
eye safe in normal operation. However, you should never look directly at a  
transmit port when it is powered on.  
Note: When selecting a fiber SFP device, considering safety, please make sure that it  
can function at a temperature that is not less than the recommended maximum  
operational temperature of the product. You must also use an approved Laser  
Class 1 SFP transceiver.  
Hinweis:Bei der Wahl eines Glasfasertransceivers muß für die Beurteilung der  
Gesamtsicherheit beachtet werden, das die maximale Umgebungstemperatur  
des Transceivers für den Betrieb nicht niedriger ist als die für dieses Produkts.  
Der Glasfasertransceiver muß auch ein überprüftes Gerät der Laser Klasse 1  
sein.  
1. Remove and keep the LC port’s rubber cover. When not connected to a fiber  
cable, the rubber cover should be replaced to protect the optics.  
2. Check that the fiber terminators are clean. You can clean the cable plugs by  
wiping them gently with a clean tissue or cotton ball moistened with a little  
ethanol. Dirty fiber terminators on fiber cables will impair the quality of the light  
transmitted through the cable and lead to degraded performance on the port.  
4-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Fiber Optic SFP Devices  
4
3. Connect one end of the cable to the LC port on the switch and the other end to  
the LC port on the other device. Since LC connectors are keyed, the cable can  
be attached in only one orientation.  
Figure 4-3 Making Connections to SFP Transceivers  
4. As a connection is made, check the Link LED on the switch corresponding to  
the port to be sure that the connection is valid.  
The 1000BASE-SX, 1000BASE-LX and 1000BASE-LH fiber optic ports operate at  
1 Gbps full duplex. The maximum length for fiber optic cable operating at Gigabit  
speed will depend on the fiber type as listed under “1000 Mbps Gigabit Ethernet  
4-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Making Network Connections  
4
Connectivity Rules  
When adding hubs (repeaters) to your network, please follow the connectivity rules  
listed in the manuals for these products. However, note that because switches break  
up the path for connected devices into separate collision domains, you should not  
include the switch or connected cabling in your calculations for cascade length  
involving other devices.  
1000BASE-T Cable Requirements  
All Category 5 UTP cables that are used for 100BASE-TX connections should also  
work for 1000BASE-T, providing that all four wire pairs are connected. However, it is  
recommended that for all critical connections, or any new cable installations,  
Category 5e (enhanced Category 5) or Category 6 cable should be used. The  
Category 5e specification includes test parameters that are only recommendations  
for Category 5. Therefore, the first step in preparing existing Category 5 cabling for  
running 1000BASE-T is a simple test of the cable installation to be sure that it  
complies with the IEEE 802.3-2005 standards.  
1000 Mbps Gigabit Ethernet Collision Domain  
Table 4-1 Maximum 1000BASE-T Gigabit Ethernet Cable Length  
Cable Type  
Maximum Cable Length  
Connector  
Category 5, 5e, 6 100-ohm UTP or STP  
100 m (328 ft)  
RJ-45  
Table 4-2 Maximum 1000BASE-SX Fiber Optic Cable Length  
Fiber Diameter  
Fiber Bandwidth  
160 MHz/km  
Cable Length Range  
2-220 m (7-722 ft)  
2-275 m (7-902 ft)  
2-500 m (7-1641 ft)  
2-550 m (7-1805 ft)  
Connector  
62.5/125 micron multimode  
fiber (MMF)  
LC  
LC  
LC  
LC  
200 MHz/km  
50/125 micron multimode fiber 400 MHz/km  
(MMF)  
500 MHz/km  
Table 4-3 Maximum 1000BASE-LX Fiber Optic Cable Length  
Fiber Diameter Fiber Bandwidth Cable Length Range  
9/125 micron single-mode fiber N/A  
Connector  
2 m - 5 km  
(7 ft - 3.2 miles)  
LC  
Table 4-4 Maximum 1000BASE-LH Fiber Optic Cable Length  
Fiber Diameter  
Fiber Bandwidth Cable Length Range  
Connector  
9/125 micron single-mode fiber N/A  
2 m - 70 km  
(7 ft - 43 miles)  
LC  
4-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                       
Connectivity Rules  
4
100 Mbps Fast Ethernet Collision Domain  
Table 4-5 Maximum Fast Ethernet Cable Length  
Type  
Cable Type  
Maximum Cable Length  
Connector  
100BASE-TX  
Category 5 or better 100-ohm 100 m (328 ft)  
UTP or STP  
RJ-45  
10 Mbps Ethernet Collision Domain  
Table 4-6 Maximum Ethernet Cable Length  
Connector  
Type  
Cable Type  
Maximum Length  
10BASE-T  
Categories 3, 4, 5 or better  
100-ohm UTP  
100 m (328 ft)  
RJ-45  
4-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
Making Network Connections  
4
Cable Labeling and Connection Records  
When planning a network installation, it is essential to label the opposing ends of  
cables and to record where each cable is connected. Doing so will enable you to  
easily locate inter-connected devices, isolate faults and change your topology  
without need for unnecessary time consumption.  
To best manage the physical implementations of your network, follow these  
guidelines:  
Clearly label the opposing ends of each cable.  
Using your building’s floor plans, draw a map of the location of all  
network-connected equipment. For each piece of equipment, identify the devices  
to which it is connected.  
Note the length of each cable and the maximum cable length supported by the  
switch ports.  
For ease of understanding, use a location-based key when assigning prefixes to  
your cable labeling.  
Use sequential numbers for cables that originate from the same equipment.  
Differentiate between racks by naming accordingly.  
Label each separate piece of equipment.  
Display a copy of your equipment map, including keys to all abbreviations at each  
equipment rack.  
4-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Appendix A: Troubleshooting  
Diagnosing Switch Indicators  
Table A-1 Troubleshooting Chart  
Symptom  
Action  
Power LED is Off  
Check connections between the switch, the power cord, and the wall  
outlet.  
Contact our Technical Support.  
Link LED is Off  
Verify that the switch and attached device are powered on.  
Be sure the cable is plugged into both the switch and corresponding  
device.  
If the switch is installed in a rack, check the connections to the  
punch-down block and patch panel.  
Verify that the proper cable type is used and its length does not exceed  
specified limits.  
Check the adapter on the attached device and cable connections for  
possible defects. Replace the defective adapter or cable if necessary.  
Power and Cooling Problems  
If the power indicator does not turn on when the power cord is plugged in, you may  
have a problem with the power outlet, power cord, or internal power supply.  
However, if the unit powers off after running for a while, check for loose power  
connections, power losses or surges at the power outlet. If you still cannot isolate  
the problem, then the internal power supply may be defective.  
A-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Troubleshooting  
A
Installation  
Verify that all system components have been properly installed. If one or more  
components appear to be malfunctioning (such as the power cord or network  
cabling), test them in an alternate environment where you are sure that all the other  
components are functioning properly.  
In-Band Access  
You can access the management agent in the switch from anywhere within the  
attached network using a Web browser, or other network management software  
tools. However, you must first configure the switch with a valid IP address, subnet  
mask, and default gateway. If you have trouble establishing a link to the  
management agent, check to see if you have a valid network connection. Then  
verify that you entered the correct IP address. Also, be sure the port through which  
you are connecting to the switch has not been disabled. If it has not been disabled,  
then check the network cabling that runs between your remote location and the  
switch.  
A-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Appendix B: Cables  
Twisted-Pair Cable and Pin Assignments  
For 10BASE-T/100BASE-TX connections, a twisted-pair cable must have two pairs  
of wires. For 1000BASE-T connections the twisted-pair cable must have four pairs of  
wires. Each wire pair is identified by two different colors. For example, one wire  
might be green and the other, green with white stripes. Also, an RJ-45 connector  
must be attached to both ends of the cable.  
Caution:  
Each wire pair must be attached to the RJ-45 connectors in a specific  
orientation.  
Caution:  
DO NOT plug a phone jack connector into any RJ-45 port. Use only  
twisted-pair cables with RJ-45 connectors that conform with FCC standards.  
Figure B-1 illustrates how the pins on the RJ-45 connector are numbered. Be sure to  
hold the connectors in the same orientation when attaching the wires to the pins.  
8
8
1
1
Figure B-1 RJ-45 Connector Pin Numbers  
10BASE-T/100BASE-TX Pin Assignments  
Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for RJ-45  
connections: 100-ohm Category 3 or better cable for 10 Mbps connections, or  
100-ohm Category 5 or better cable for 100 Mbps connections. Also be sure that the  
length of any twisted-pair connection does not exceed 100 meters (328 feet).  
The RJ-45 ports on the switch base unit support automatic MDI/MDI-X operation, so  
you can use straight-through cables for all network connections to PCs or servers, or  
to other switches or hubs. In straight-through cable, pins 1, 2, 3, and 6, at one end of  
the cable, are connected straight through to pins 1, 2, 3, and 6 at the other end of  
the cable. When using any RJ-45 port on the switch, you can use either  
straight-through or crossover cable.  
B-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
Cables  
B
Table B-1 10/100BASE-TX MDI-X and MDI Port Pinouts  
Pin  
MDI Signal Name  
MDI-X Signal Name  
1
Receive Data plus (RD+)  
Transmit Data plus (TD+)  
and GND (Positive V  
)
and -48V feeding power (Negative V  
)
)
port  
port  
2
Receive Data minus (RD-) and  
and GND (Positive V  
Transmit Data minus (TD-)  
and -48V feeding power (Negative V  
)
port  
port  
3
Transmit Data plus (TD+)  
Receive Data plus (RD+)  
and -48V feeding power (Negative V  
)
)
and GND (Positive V  
)
port  
port  
6
Transmit Data minus (TD-)  
and -48V feeding power (Negative V  
Receive Data minus (RD-)  
and GND (Positive V  
)
port  
port  
4, 5, 7, 8  
Not used  
Not used  
Note: The “+” and “-” signs represent the polarity of the wires that make up each wire pair.  
Straight-Through Wiring  
If the twisted-pair cable is to join two ports and only one of the ports has an internal  
crossover (MDI-X), the two pairs of wires must be straight-through. (When  
auto-negotiation is enabled for any RJ-45 port on the switch, you can use either  
straight-through or crossover cable to connect to any device type.)  
You must connect all four wire pairs as shown in the following diagram to support  
Gigabit Ethernet connections.  
EIA/TIA 568B RJ-45 Wiring Standard  
10/100BASE-TX Straight-through Cable  
White/Orange Stripe  
Orange  
White/Green Stripe  
Blue  
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
End A  
End B  
White/Blue Stripe  
Green  
White/Brown Stripe  
Brown  
Figure B-2 Straight-through Wiring  
Crossover Wiring  
If the twisted-pair cable is to join two ports and either both ports are labeled with an  
“X” (indicating MDI-X) or neither port is labeled with an “X” (which indicates MDI), a  
crossover must be implemented in the wiring. (When auto-negotiation is enabled for  
B-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Twisted-Pair Cable and Pin Assignments  
B
any RJ-45 port on the switch, you can use either straight-through or crossover cable  
to connect to any device type.)  
You must connect all four wire pairs as shown in the following diagram to support  
Gigabit Ethernet connections.  
EIA/TIA 568B RJ-45 Wiring Standard  
10/100BASE-TX Crossover Cable  
White/Orange Stripe  
Orange  
White/Green Stripe  
Blue  
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
End A  
End B  
White/Blue Stripe  
Green  
White/Brown Stripe  
Brown  
Figure B-3 Crossover Wiring  
1000BASE-T Pin Assignments  
All 1000BASE-T ports support automatic MDI/MDI-X operation, so you can use  
straight-through cables for all network connections to PCs or servers, or to other  
switches or hubs.  
The table below shows the 1000BASE-T MDI and MDI-X port pinouts. These ports  
require that all four pairs of wires be connected. Note that for 1000BASE-T  
operation, all four pairs of wires are used for both transmit and receive.  
Use 100-ohm Category 5, 5e or 6 unshielded twisted-pair (UTP) or shielded  
twisted-pair (STP) cable for 1000BASE-T connections. Also be sure that the length  
of any twisted-pair connection does not exceed 100 meters (328 feet).  
Table B-2 1000BASE-T MDI-X and MDI Port Pinouts  
1000BASE-T MDI-X and MDI Port Pinouts  
Pin  
1
MDI-X Signal Name  
MDI Signal Name  
Bi-directional Data Two Plus (BI_D2+)  
Bi-directional Data Two Minus (BI_D2-)  
Bi-directional Data One Plus (BI_D1+)  
Bi-directional Data Four Plus (BI_D4+)  
Bi-directional Data Four Minus (BI_D4-)  
Bi-directional Data One Plus (BI_D1+)  
Bi-directional Data One Minus (BI_D1-)  
Bi-directional Data Two Plus (BI_D2+)  
Bi-directional Data Three Plus (BI_D3+)  
Bi-directional Data Three Minus (BI_D3-)  
2
3
4
5
B-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
Cables  
B
1000BASE-T MDI-X and MDI Port Pinouts  
Pin  
MDI-X Signal Name  
MDI Signal Name  
6
7
8
Bi-directional Data One Minus (BI_D1-)  
Bi-directional Data Three Plus (BI_D3+)  
Bi-directional Data Three Minus (BI_D3-)  
Bi-directional Data Two Minus (BI_D2-)  
Bi-directional Data Four Plus (BI_D4+)  
Bi-directional Data Four Minus (BI_D4-)  
Cable Testing for Existing Category 5 Cable  
Installed Category 5 cabling must pass tests for Attenuation, Near-End Crosstalk  
(NEXT), and Far-End Crosstalk (FEXT). This cable testing information is specified in  
the ANSI/TIA/EIA-TSB-67 standard. Additionally, cables must also pass test  
parameters for Return Loss and Equal-Level Far-End Crosstalk (ELFEXT). These  
tests are specified in the ANSI/TIA/EIA-TSB-95 Bulletin, “The Additional  
Transmission Performance Guidelines for 100 Ohm 4-Pair Category 5 Cabling.”  
Note that when testing your cable installation, be sure to include all patch cables  
between switches and end devices.  
Adjusting Existing Category 5 Cabling to Run 1000BASE-T  
If your existing Category 5 installation does not meet one of the test parameters for  
1000BASE-T, there are basically three measures that can be applied to try and  
correct the problem:  
1. Replace any Category 5 patch cables with high-performance Category 5e or  
Category 6 cables.  
2. Reduce the number of connectors used in the link.  
3. Reconnect some of the connectors in the link.  
Fiber Standards  
The current TIA (Telecommunications Industry Association) 568-A specification on  
optical fiber cabling consists of one recognized cable type for horizontal subsystems  
and two cable types for backbone subsystems.  
Horizontal 62.5/125 micron multimode (two fibers per outlet).  
Backbone 62.5/125 micron multimode or single mode.  
TIA 568-B will allow the use of 50/125 micron multimode optical fiber in both the  
horizontal and backbone in addition to the types listed above. All optical fiber  
components and installation practices must meet applicable building and safety  
codes.  
B-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Appendix C: Specifications  
Physical Characteristics  
Ports  
8 10/100/1000BASE-T, with auto-negotiation  
1 SFP transceiver slot.  
Network Interface  
Ports 1-8: RJ-45 connector, auto MDI/X  
10BASE-T: RJ-45 (100-ohm, UTP cable; Category 3 or better)  
100BASE-TX: RJ-45 (100-ohm, UTP cable; Category 5 or better)  
1000BASE-T: RJ-45 (100-ohm, UTP or STP cable; Category 5, 5e, or 6)  
*Maximum Cable Length - 100 m (328 ft)  
Buffer Architecture  
144 Kbytes  
Aggregate Bandwidth  
16 Gbps  
Switching Database  
4K MAC address entries  
LEDs  
System: Power  
Port: Link/Act; Status for SFP ports; PoE  
Weight  
2.06 kg (4.54 lbs)  
Size  
33.0 x 20.3 x 4.4 cm (12.99 x 7.99 x 1.73 in.)  
Temperature  
Operating: 0 to 45 °C (32 to 114 °F)  
Storage: -40 to 70 °C (-40 to 158 °F)  
Humidity  
Operating: 10% to 90% (non-condensing)  
C-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Specifications  
C
AC Input  
100 to 240 V, 50-60 Hz, 1.5 A  
Power-over-Ethernet  
Input voltage: 48 V DC  
Maximum output power 70 W:  
15.4 W for any four ports simultaneously  
port 1 can provide 25 W  
Maximum output current per port: 350 mA DC  
port 1 can reach: 565 mA DC  
Output Voltage: 44 - 57 V DC  
Maximum output current per port: 350 mA DC  
Power Supply  
Internal, auto-ranging transformer: 100 to 240 VAC, 50 to 60 Hz  
Power Consumption  
165 W maximum (full PoE load)  
Maximum Current  
1.5 A @ 110 VAC  
0.75 A @ 220 VAC  
Switch Features  
Forwarding Mode  
Store-and-forward  
Throughput  
Wire speed  
Management Features  
In-Band Management  
Web and SNMP  
Software Loading  
HTTP in-band  
C-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Standards  
C
Standards  
IEEE 802.3-2005  
Ethernet, Fast Ethernet, Gigabit Ethernet  
IEEE 802.3af Power-over-Ethernet  
IEEE 802.1D Spanning Tree Protocol  
IEEE D802.1Q Virtual LAN  
IEEE 802.1X, Port-Based Network Access Control, 2001  
ISO/IEC 8802-3  
Compliances  
CE Mark  
Emissions  
FCC Class A  
Immunity  
EN 61000-4-2/3/4/5/6/8/11  
Safety  
CB (IEC60950-1, EN60950-1)  
C-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Specifications  
C
C-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Glossary  
10BASE-T  
IEEE 802.3 specification for 10 Mbps Ethernet over two pairs of Category 3 or better  
UTP cable.  
100BASE-TX  
IEEE 802.3u specification for 100 Mbps Fast Ethernet over two pairs of Category 5  
or better UTP cable.  
1000BASE-LH  
Specification for long-haul Gigabit Ethernet over two strands of 9/125 micron core  
fiber cable.  
1000BASE-LX  
IEEE 802.3z specification for Gigabit Ethernet over two strands of  
50/125, 62.5/125 or 9/125 micron core fiber cable.  
1000BASE-SX  
IEEE 802.3z specification for Gigabit Ethernet over two strands of  
50/125 or 62.5/125 micron core fiber cable.  
1000BASE-T  
IEEE 802.3ab specification for Gigabit Ethernet over 100-ohm Category 5 or 5e  
twisted-pair cable (using all four wire pairs).  
Auto-Negotiation  
Signalling method allowing each node to select its optimum operational mode (e.g.,  
speed and duplex mode) based on the capabilities of the node to which it is  
connected.  
Bandwidth  
The difference between the highest and lowest frequencies available for network  
signals. Also synonymous with wire speed, the actual speed of the data  
transmission along the cable.  
Collision  
A condition in which packets transmitted over the cable interfere with each other.  
Their interference makes both signals unintelligible.  
Collision Domain  
Single CSMA/CD LAN segment.  
Glossary-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Glossary  
CSMA/CD  
CSMA/CD (Carrier Sense Multiple Access/Collision Detect) is the communication  
method employed by Ethernet, Fast Ethernet, or Gigabit Ethernet.  
End Station  
A workstation, server, or other device that does not forward traffic.  
Ethernet  
A network communication system developed and standardized by DEC, Intel, and  
Xerox, using baseband transmission, CSMA/CD access, logical bus topology, and  
coaxial cable. The successor IEEE 802.3 standard provides for integration into the  
OSI model and extends the physical layer and media with repeaters and  
implementations that operate on fiber, thin coax and twisted-pair cable.  
Fast Ethernet  
A 100 Mbps network communication system based on Ethernet and the CSMA/CD  
access method.  
Full Duplex  
Transmission method that allows two network devices to transmit and receive  
concurrently, effectively doubling the bandwidth of that link.  
Gigabit Ethernet  
A 1000 Mbps network communication system based on Ethernet and the CSMA/CD  
access method.  
IEEE  
Institute of Electrical and Electronic Engineers.  
IEEE 802.3  
Defines carrier sense multiple access with collision detection (CSMA/CD) access  
method and physical layer specifications.  
IEEE 802.3ab  
Defines CSMA/CD access method and physical layer specifications for  
1000BASE-T Gigabit Ethernet. (Now incorporated in IEEE 802.3-2005.)  
IEEE 802.3u  
Defines CSMA/CD access method and physical layer specifications for  
100BASE-TX Fast Ethernet. (Now incorporated in IEEE 802.3-2005.)  
Glossary-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Glossary  
IEEE 802.3x  
Defines Ethernet frame start and stop requests and timers used for flow control on  
full-duplex links. (Now incorporated in IEEE 802.3-2005.)  
IEEE 802.3z  
Defines CSMA/CD access method and physical layer specifications for 1000BASE  
Gigabit Ethernet. (Now incorporated in IEEE 802.3-2005.)  
LAN Segment  
Separate LAN or collision domain.  
Layer 2  
Data Link layer in the ISO 7-Layer Data Communications Protocol. This is related  
directly to the hardware interface for network devices and passes on traffic based on  
MAC addresses.  
LED  
Light emitting diode used for monitoring a device or network condition.  
Link Segment  
Length of twisted-pair or fiber cable joining a pair of repeaters or a repeater and a  
PC.  
Local Area Network (LAN)  
A group of interconnected computers and support devices.  
Management Information Base (MIB)  
An acronym for Management Information Base. It is a set of database objects that  
contains information about the device.  
Media Access Control (MAC)  
A portion of the networking protocol that governs access to the transmission  
medium, facilitating the exchange of data between network nodes.  
Modal Bandwidth  
Bandwidth for multimode fiber is referred to as modal bandwidth because it varies  
with the modal field (or core diameter) of the fiber. Modal bandwidth is specified in  
units of MHz per km, which indicates the amount of bandwidth supported by the fiber  
for a one km distance.  
Network Diameter  
Wire distance between two end stations in the same collision domain.  
Glossary-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Glossary  
Redundant Power Supply (RPS)  
A backup power supply unit that automatically takes over in case the primary power  
supply should fail.  
RJ-45 Connector  
A connector for twisted-pair wiring.  
Switched Ports  
Ports that are on separate collision domains or LAN segments.  
TIA  
Telecommunications Industry Association  
Transmission Control Protocol/Internet Protocol (TCP/IP)  
Protocol suite that includes TCP as the primary transport protocol, and IP as the  
network layer protocol.  
UTP  
Unshielded twisted-pair cable.  
Virtual LAN (VLAN)  
A Virtual LAN is a collection of network nodes that share the same collision domain  
regardless of their physical location or connection point in the network. A VLAN  
serves as a logical workgroup with no physical barriers, allowing users to share  
information and resources as though located on the same LAN.  
Glossary-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
Numerics  
D
10 Mbps connectivity rules 4-7  
100 Mbps connectivity rules 4-7  
1000 Mbps connectivity rules 4-6  
1000BASE-LH fiber cable lengths 4-6  
1000BASE-LX fiber cable lengths 4-6  
1000BASE-SX fiber cable lengths 4-6  
1000BASE-T  
desktop mounting 3-4  
device connections 4-1  
E
electrical interference, avoiding 3-1  
equipment checklist 3-2  
Ethernet connectivity rules 4-6, 4-7  
pin assignments B-3  
ports 1-3  
100BASE-TX  
F
Fast Ethernet connectivity rules 4-7  
features C-2  
management 1-5  
full-duplex connectivity 2-1  
cable lengths 4-7  
ports 1-3  
10BASE-T ports 1-3  
10BASE-T/100BASE-TX pin  
assignments B-1  
G
grounding for racks 3-3  
A
adhesive feet, attaching 3-4  
air flow requirements 3-1  
applications  
collapsed backbone 2-2  
VLAN connections 2-3  
I
IEEE 802.3 Ethernet 1-5  
IEEE 802.3ae 10 Gigabit Ethernet 1-5  
IEEE 802.3u Fast Ethernet 1-5  
IEEE 802.3z Gigabit Ethernet 1-5  
indicators, LED 1-3  
B
installation  
brackets, attaching 3-3  
buffer size C-1  
connecting devices to the switch 4-2  
desktop or shelf mounting 3-4  
port connections 4-1  
power requirements 3-1  
problems A-2  
rack mounting 3-3  
site requirements 3-1  
wiring closet connections 4-7  
C
cable  
Ethernet cable compatibility 3-1  
labeling and connection records 4-8  
lengths 4-7  
cleaning fiber terminators 4-4  
connectivity rules  
10 Mbps 4-7  
100 Mbps 4-7  
1000 Mbps 4-6  
L
laser safety 4-4  
LC port connections 4-4  
LED indicators  
Power 1-4  
problems A-1  
location requirements 3-1  
contents of package 3-2  
cooling problems A-1  
cord sets, international 3-6  
Index-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Index  
switching, introduction to 2-1  
M
management  
agent 1-2  
T
temperature within a rack 3-3  
troubleshooting  
in-band access A-2  
power and cooling problems A-1  
switch indicators A-1  
twisted-pair connections 4-1  
features 1-5, C-2  
SNMP 1-2  
mounting the switch  
in a rack 3-3  
on a desktop or shelf 3-4  
N
V
network  
VLANs  
connections 4-1  
examples 2-2  
tagging 2-4  
P
package contents 3-2  
pin assignments B-1  
1000BASE-T B-3  
100BASE-TX/10BASE-T B-1  
ports, connecting to 4-1  
power, connecting to 3-6  
problems, troubleshooting A-1  
R
rack mounting 3-3  
rear panel receptacles 1-4  
RJ-45 port 1-3  
connections 4-1  
pinouts B-3  
rubber foot pads, attaching 3-4  
S
screws for rack mounting 3-2  
site selelction 3-1  
SNMP agent 1-2  
specifications  
compliances C-2  
environmental C-1  
physical C-1  
power C-2  
standards  
IEEE C-3  
status LEDs 1-3  
surge suppressor, using 3-1  
switch architecture 1-2  
Index-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
JAN/2008/ISSUE 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Coffeemaker 09 732 150 User Manual
Miele Oven H4890BP2 User Manual
MTD Blower 245 692 000 User Manual
NEC Telephone 10930 95 User Manual
NETGEAR Network Router DG834GV v2 User Manual
Net Optics Switch 4xN100 User Manual
Nikon Camera Lens 2198 User Manual
Nilfisk Advance America Pressure Washer E 1302 User Manual
Olicom Network Router A400A User Manual
Omega Speaker Systems Switch RD8300 User Manual