Network Technologies Switch UNIMUX USBV 4 User Manual

R NETWORK  
INCORPORATED  
Tel:330-562-7070  
TECHNOLOGIES Aurora, OH 44202 Fax:330-562-1999  
1275 Danner Dr  
NTI  
UNIMUXTM Series  
UNIMUX-USBV-4/2 (4/2-Port USB KVM Switch)  
INSTALLATION / USER GUIDE  
MAN026 Rev Date 8/19/2003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
INTRODUCTION.............................................................................................................................................................1  
Available Options:........................................................................................................................................................1  
MATERIALS....................................................................................................................................................................1  
FEATURES AND FUNCTIONS.......................................................................................................................................2  
INSTALLATION...............................................................................................................................................................3  
Power-Up Sequence....................................................................................................................................................5  
USING THE NTI SWITCH...............................................................................................................................................5  
Front Panel Control......................................................................................................................................................5  
Keyboard Control.........................................................................................................................................................5  
MODES OF OPERATION...............................................................................................................................................6  
Basic Command Mode ................................................................................................................................................6  
Broadcast Mode...........................................................................................................................................................7  
Scan Mode...................................................................................................................................................................7  
Normal Mode ...............................................................................................................................................................7  
Select Country Code....................................................................................................................................................7  
OPTIONAL OSD CONTROL...........................................................................................................................................8  
Security Option ............................................................................................................................................................8  
Enabling The Security Feature....................................................................................................................................8  
User Login Mode .........................................................................................................................................................9  
ADDITIONAL OSD MODES AVAILABLE WITH SECURITY..........................................................................................9  
Administration Mode....................................................................................................................................................9  
Administrator Password.............................................................................................................................................10  
User Name List..........................................................................................................................................................10  
Edit User....................................................................................................................................................................11  
Alternate Command Hot Key.....................................................................................................................................12  
Command Mode ........................................................................................................................................................12  
Scan Mode.................................................................................................................................................................14  
Broadcast Mode.........................................................................................................................................................14  
Normal Mode .............................................................................................................................................................14  
Edit Mode...................................................................................................................................................................14  
Change Settings ........................................................................................................................................................15  
Broadcast Mode Configuration..................................................................................................................................16  
Scan Mode Configuration..........................................................................................................................................16  
MAC Ports Configuration...........................................................................................................................................17  
Maintenance Mode ....................................................................................................................................................17  
Search Mode .............................................................................................................................................................18  
Help Mode .................................................................................................................................................................19  
F3- Display Information..............................................................................................................................................19  
KEYBOARD FEATURES ..............................................................................................................................................20  
Keyboard-To-Computer Translation..........................................................................................................................20  
Translation Capabilities .............................................................................................................................................20  
Translation Tables .....................................................................................................................................................20  
International Sun Keyboards .....................................................................................................................................21  
CASCADING.................................................................................................................................................................22  
Limitations..................................................................................................................................................................23  
Cable Connections ....................................................................................................................................................23  
Operating Cascaded Switches ..................................................................................................................................24  
DDC SUPPORT (OPTIONAL).......................................................................................................................................25  
TECHNICAL SPECIFICATIONS...................................................................................................................................25  
TROUBLESHOOTING ..................................................................................................................................................26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF FIGURES  
Figure 1- Connect the devices and Monitor ....................................................................................................................3  
Figure 2- Connect a CPU................................................................................................................................................4  
Figure 3- Country Codes for international SUN keyboards.............................................................................................7  
Figure 4- User Login screen............................................................................................................................................8  
Figure 5- Administration Mode menu..............................................................................................................................9  
Figure 6- Administrator Password screen.....................................................................................................................10  
Figure 7- User Name List ..............................................................................................................................................10  
Figure 8- Edit the user access list.................................................................................................................................11  
Figure 9- User level Command Mode ...........................................................................................................................12  
Figure 10- Additional Command Mode options.............................................................................................................13  
Figure 11- Change Setting menu..................................................................................................................................15  
Figure 12- Select ports for broadcasting.......................................................................................................................16  
Figure 13- Maintenance Mode menu ............................................................................................................................17  
Figure 14- Information provided by the F3 command...................................................................................................19  
Figure 15- Keyboard Layouts........................................................................................................................................21  
Figure 16- Cascaded UNIMUX-USBV-4O USB KVM switches ....................................................................................22  
Figure 17- Cascaded configuration with multi-user slaves ...........................................................................................23  
Figure 18- Cascaded switch cable connections............................................................................................................24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
The UNIMUX-USBV-4 (formerly referred to as KEEMUX-USBV-4U) USB KVM switch allows one user to access four USB CPUs  
with only one USB keyboard, USB mouse, and 15HD VGA monitor. Internal microprocessors allow all CPUs to boot  
simultaneously and error-free. Port selection is accomplished by a front panel push button or commands typed on the keyboard.  
Available Options:  
UNIMUX-USBV-2 USB KVM switch with connections to access two USB CPUs rather than four.  
UNIMUX-USBV-4O USB KVM switch with OSD (On Screen Display) feature (not available on 2 port switch)  
Configuration is expandable by cascading switches (UNIMUX-USBV-4O only)  
UNIMUX-USBV-4D USB KVM switch with DDC support (not available on 2 port switch)  
Types of User Input Devices and Monitors Supported:  
USB keyboard with Windows® layout  
USB keyboard with SUN layout  
USB keyboard with MAC layout with mouse  
USB Mouse - (up to 3 buttons)  
USB IntelliMouse® (scrollwheel)  
NTI USB-SUN Adapter  
USB Hub  
Mouse-trak track-ball  
Logitech, Kensington and Microsoft Wheelmouse or Trackball on Mac CPUs with special drivers(OSD Version  
only)  
Logitech Cordless Elite Duo keyboard and mouse  
Crystal Vision keyboard with touchpad  
Gyration keyboard/mouse  
NTI PS2/USB Adapter  
VGA, XGA, SVGA, and most DVI monitors (when used with NTI DVIF-15HDM adapter)  
ADC monitors (when the DDC support option is installed and when using an appropriate VGA-ADC converter)  
Types of CPUs Supported:  
Any USB CPU supporting USB version 1.0 or above including:  
USB WINxx  
USB MAC  
USB SUN  
MATERIALS  
Materials Supplied with this kit:  
1- NTI UNIMUX-USBV-4 / UNIMUX-USBV-2 USB KVM Switch  
1- 5VDC 2A AC Adapter  
Materials Not Supplied, BUT REQUIRED:  
A USBVEXT-xx-MM cable for each USB CPU being connected to the switch must be used for monitor and device (keyboard and  
mouse) interface.  
Legend:  
xx is the length of the cable in feet  
MM indicates male-to-male connector  
Cables can be purchased from Network Technologies Inc by calling (800) 742-8324 (800-RGB-TECH) in the US and Canada or  
(330) 562-7070 (worldwide).  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
F
E
A
T
U
R
E
S
A
N
D
F
U
N
C
T
I
O
N
S
R
e
a
r
V
i
e
w
o
f
U
N
I
M
U
X
-
U
S
B
V
-
4
F
r
o
n
t
V
i
e
w
o
f
U
N
I
M
U
X
-
U
S
B
V
-
4
1
0
6
5
2
3
1
R
N
E
T
W
O
R
K
T
E
C
H
N
O
L
O
G
I
E
S
I
N
C
O
R
P
O
R
A
T
E
D
1
2
7
5
D
a
n
n
e
r
D
r
i
v
e
,
A
u
r
o
r
a
O
h
i
o
4
4
2
0
2
3
3
0
-
5
6
2
-
7
0
7
0
w
w
w
.
n
t
i
1
.
c
o
m
N
T
I
R
M
O
N
I
T
O
R
V
I
D
E
O
4
V
I
D
E
O
3
V
I
D
E
O
2
V
I
D
E
O
1
D
D
C
U
N
I
M
U
X
N
T
I
N
e
t
w
o
r
k
T
e
c
h
n
o
l
o
g
i
e
s
I
n
c
B
R
O
A
D
U
S
B
C
O
M
S
C
A
N
C
A
S
T
D
E
V
I
C
E
S
M
A
N
D
C
P
U
4
C
P
U
3
C
P
U
2
C
P
U
1
5
V
2
D
C
A
2
3
4
1
+
-
7
9
8
4
FEATURES AND FUNCTIONS  
1. Power Switch- to power up or power down the UNIMUX-USBV-4 USB KVM switch.  
2. Mode Status LEDs- for visual indication of switch operating mode  
3. CPU Status LEDs- for visual indication of switch connection between the user and a specific CPU  
4. CPU Select Switch- press to manually switch to a specific CPU or to change the switch operating mode  
5. MONITOR- 15HD female connector- for connection of the user video monitor  
6. VIDEO x- 15HD female connectors- for connecting video cables from CPUs  
7. 5VDC- connection jack for the AC adapter  
8. CPU x- USB type B female connectors-for connection of USB device cables from CPUs  
9. USB DEVICES- USB type A female connectors- for connection of user USB device(s)  
10. DDC button- for manual update of DDC information between the monitor and the CPU(s) attached (optional)  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
1. It is not necessary to turn OFF power to any of the CPUs that will be connected to the UNIMUX-USBV-4 USB KVM switch  
before connecting or disconnecting any cables.  
NOTE: If a CPU needs to identify a keyboard, it will be necessary to power ON the CPU after it is connected to the  
UNIMUX-USBV-4 USB KVM switch and only after the keyboard is connected and the UNIMUX-USBV-4 USB  
KVM switch is powered ON.  
2. Connect a USB keyboard to a female USB type A port labeled "USB DEVICES" on the UNIMUX-USBV-4 USB KVM switch.  
See Fig. 1.  
3. Connect a USB mouse to the other female USB type A port labeled "USB DEVICES" on the UNIMUX-USBV-4 USB KVM  
switch.  
4. Connect a VGA multi-scan monitor to the female 15HD VGA port labeled "MONITOR" on the UNIMUX-USBV-4 USB KVM  
switch. Be sure to tighten the two screws on the monitor cable connector to the UNIMUX-USBV-4 USB KVM switch  
securely.  
Note: If the DDC Support option is installed, a monitor with the DDC feature must be connected to the "MONITOR" port.  
(DDC Support option not available on 2 port switches.)  
1
5
H
D
F
e
m
a
l
e
V
i
d
e
o
C
o
n
n
e
c
t
o
r
M
O
N
I
T
O
R
1
5
H
D
M
a
l
e
V
i
d
e
o
C
o
n
n
e
c
t
o
r
R
e
a
r
V
i
e
w
o
f
K
E
E
M
U
X
-
U
S
B
V
-
4
U
R
N
E
T
W
O
R
K
T
E
C
H
N
O
L
O
G
I
E
S
I
N
C
O
R
P
O
R
A
T
E
D
1
2
7
5
D
a
n
n
e
r
D
r
i
v
e
,
A
u
r
o
r
a
O
h
i
o
4
4
2
0
2
3
3
0
-
5
6
2
-
7
0
7
0
w
w
w
.
n
t
i
1
.
c
o
m
N
T
I
M
O
N
I
T
O
R
V
I
D
E
O
4
V
I
D
E
O
3
V
I
D
E
O
2
V
I
D
E
O
1
U
S
B
V
G
A
D
E
V
I
C
E
S
C
P
U
4
C
P
U
3
C
P
U
2
C
P
U
1
5
V
2
D
C
M
u
l
t
i
-
S
c
a
n
A
M
o
n
i
t
o
r
-
+
U
S
B
T
y
p
e
A
M
a
l
e
U
S
B
T
y
p
e
A
F
e
m
a
l
e
U
S
B
M
O
U
S
E
U
S
B
K
E
Y
B
O
A
R
D
Figure 1- Connect the devices and Monitor  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Using the USB cable ends of a USB-VEXT-xx-MM cable connect the USB type A device port of a USB CPU to the USB  
type B port labeled "CPU 1" on the UNIMUX-USBV-4 USB KVM switch.  
6. Using the 15HD male video connector ends of the same USB-VEXT-xx-MM, connect the video port of the same USB CPU  
connected in step 5 to the female 15HD port labeled "VIDEO 1" on the UNIMUX-USBV-4 USB KVM switch . Be sure to  
tighten the two screws on the cable connector to the UNIMUX-USBV-4 USB KVM switch securely. See Fig. 2.  
7. Repeat steps 5 and 6 for connecting each additional USB CPU to the ports labeled "CPU 2" and "VIDEO 2", "CPU 3" and  
"VIDEO 3", etc.  
R
e
a
r
V
i
e
w
o
f
U
N
I
M
U
X
-
U
S
B
V
-
4
V
I
D
E
O
4
R
N
E
T
W
O
R
K
T
E
C
H
N
O
L
O
G
I
E
S
I
N
C
O
R
P
O
R
A
T
E
D
1
2
7
5
D
a
n
n
e
r
D
r
i
v
e
,
A
u
r
o
r
a
O
h
i
o
4
4
2
0
2
3
3
0
-
5
6
2
-
7
0
7
0
w
w
w
.
n
t
i
1
.
c
o
m
N
T
I
M
O
N
I
T
O
R
V
I
D
E
O
4
V
I
D
E
O
3
V
I
D
E
O
2
V
I
D
E
O
1
1
5
H
D
F
e
m
a
l
e
V
i
d
e
o
C
o
n
n
e
c
t
o
r
U
S
B
D
E
V
I
C
E
S
C
P
U
4
C
P
U
3
C
P
U
2
C
P
U
1
5
V
2
D
C
A
+
-
U
S
B
T
y
p
e
B
R
e
a
r
V
i
e
w
o
f
W
i
n
d
o
w
s
U
S
B
C
P
U
M
a
l
e
U
S
B
T
y
p
e
A
M
a
l
e
U
S
B
T
y
p
e
B
I
n
p
u
t
D
e
v
i
c
e
P
o
r
t
F
e
m
a
l
e
C
o
n
n
e
c
t
o
r
U
S
B
T
y
p
e
A
F
e
m
a
l
e
V
i
d
e
o
P
o
r
t
U
S
B
V
E
X
T
-
x
x
-
M
M
1
5
H
D
F
e
m
a
l
e
V
i
d
e
o
C
o
n
n
e
c
t
o
r
Figure 2- Connect a CPU  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Power-Up Sequence  
The UNIMUX-USBV-4 USB KVM switch can be powered at any time. The CPUs can be powered at any time although if a CPU  
needs a keyboard and/or mouse at power-ON it should be powered after connecting to and powering-ON the UNIMUX-USBV-4  
USB KVM switch. USB devices (keyboard and mouse) can be hot plugged to and from the UNIMUX-USBV-4 USB KVM switch at  
any time.  
Note: If the DDC support option is installed, the UNIMUX-USBV-4 and the monitor must be powered up before any CPUs  
are powered up.  
Immediately after powering ON the UNIMUX-USBV-4 USB KVM switch, the following splash screen will appear on the monitor if  
the OSD option is built into the switch:  
If the security option is enabled (see page 8 for details on the "Security Option"), when the user presses any key the user will be  
prompted for a username and password to continue. If the security option is not enabled, when the user presses any key the  
splash screen will disappear, the monitor will display the desktop image for the connected CPU, and the user can resume normal  
operation of the connected CPU.  
USING THE NTI SWITCH  
Front Panel Control  
There is a touch-switch and LED on the front panel of the UNIMUX-USBV-4 USB KVM switch for each CPU the switch will  
connect the monitor and input devices to. Pressing any touch-switch on the front panel of the KEEMUX-USBV-xU USB KVM  
switch will connect the corresponding CPU to the monitor and input devices.  
Holding down any front panel touch-switch for more than 2 seconds will cause the UNIMUX-USBV-4 USB KVM switch to  
cycle through all modes of operation including COMMAND, BROADCAST, SCAN, and NORMAL (described on pages 5-7). The  
two MODE LEDs on the front panel indicate which mode is selected. Release the touch-switch when the LEDs indicate the  
desired mode. When no mode LEDs are illuminated the user is in Normal Mode controlling directly the CPU to which the user is  
connected through the UNIMUX-USBV-4 USB KVM switch.  
Keyboard Control  
Keyboard control of the UNIMUX-USBV-4 USB KVM switch can be achieved through either  
Basic Command Mode- Basic Command Mode is operated strictly by using keyboard commands as instructed below. Basic  
Command Mode is only applicable if the OSD option is not built into the switch.  
-OR-  
OSD Command Mode (optional- only available on 4 port switch )- OSD Command Mode is operated using the input devices in  
conjunction with OSD menus superimposed onto the monitor. If OSD is built in, use the menus as instructed on page 8.  
By pressing <Ctrl> + ` (accent key), the user can enter Command Mode (either Basic, or OSD). Once in Command Mode, typing  
a series of commands will cause the UNIMUX-USBV-4 USB KVM switch to connect the user to any one CPU connected to the  
switch. Pressing the <Esc> key will exit Command Mode.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODES OF OPERATION  
Basic Command Mode  
In order to control the UNIMUX-USBV-4 USB KVM switch with the keyboard connected, Command Mode must be enabled. To  
enter Command Mode from the keyboard:  
(ACCENT  
KEY)  
~
Press  
Ctrl  
+
`
NOTE: IF THE OSD FEATURE HAS BEEN INSTALLED (ONLY AVAILABLE ON 4 PORT  
SWITCH), PROCEED DIRECTLY TO “OPTIONAL OSD CONTROL” ON PAGE 8. If not,  
continue on the next page.  
When the COMMAND LED is illuminated, all 3 status lights on the keyboard will illuminate (if they aren't already due to caps lock,  
scroll lock, and/or num lock) to indicate that Command Mode is enabled and the following functions are available:  
Command Functions  
KEY SYMBOLS LEGEND:  
Function:  
Keystroke:  
or  
PRESS EITHER KEY  
CHORDED SEQUENCE- PRESS CONSECUTIVELY  
AND KEEP KEYS PRESSED UNTIL ALL ARE PRESSED.  
(select the next  
higher port  
ex. 03 04)  
+
-
Increment Port  
I or or  
PRESS CONSECUTIVELY  
(select the next  
lower port  
ex. 02 01)  
Decrement Port  
or  
or  
D
Toggle Broadcast Mode  
ON and OFF  
(The Broadcast Mode LED will toggle ON and OFF.)  
B
S
Toggle Scan Mode  
ON and OFF  
(The SCAN Mode LED will  
also toggle ON and OFF)  
(xxx from 002 to 255. ie. t002  
would set the time-out period  
for 2 seconds)  
Sets scan time-out  
period for each port.  
(0-2)  
x
(0-9)  
x
(0-9)  
x
-
T
-
-
(0-9)  
x
(0-9)  
x
(Pxx would be P01, P02, etc.)  
Selects a specific  
port  
-
P
L
-
(xx= any number from  
00 to 34. See Country  
Codes table on page 7. )  
Select a specific  
Country code  
x
x
x
-
-
(x= 1 or 2 <M> + <1> will enable function on Port 1  
<M> + <2> will enable function on Port 2. Keyboard  
LED's will flash once to confirm command. )  
Configure port to connect  
To a MAC CPU  
M
+
+
(x= 1 or 2 <W> + <1> will disable function on Port 1  
<W> + <2> will disable function on Port 2. Keyboard  
LED's will flash once to confirm command. )  
Configure port to connect  
To a WINDOWS or SUN  
CPU  
x
W
Note: The user must exit Command Mode to type to a CPU.  
Exit Command Mode  
Esc  
To exit Command Mode, either hold down any touch-switch on  
the front panel for more than 2 seconds, OR press <ESC> on the  
keyboard.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Broadcast Mode  
Broadcast Mode enables the user to type characters to all CPUs simultaneously. A port doesn’t receive broadcast data if  
Security Mode is enabled and the user does not have access rights to the port.  
NOTE: The user must type somewhat slowly when in Broadcast Mode (less than 20 wpm) and cannot use the  
<Backspace> key.  
Scan Mode  
When in Scan Mode the switch scans to each port with a CPU powered-ON. (The SCAN LED on the front panel will illuminate and  
remain ON while in Scan Mode. ) The port with the CPU powered-ON remains active while in use until it becomes idle for the  
configured dwell time (default time-out period is 5 seconds) before switching to the next powered-ON CPU port. See Command  
Mode section above for configuring the scan dwell time.  
NOTE: The keyboard and mouse must remain idle for the full scan dwell time before the switch selects the next active  
port.  
Normal Mode  
When all of the UNIMUX-USBV-4 USB KVM switch mode LEDs are OFF the user is in Normal Mode, controlling the CPU to which  
the user is connected through the UNIMUX-USBV-4 USB KVM switch.  
Select Country Code  
It is possible to configure the UNIMUX-USBV-4 USB KVM switch to emulate a specific international Sun keyboard regardless of  
what actual keyboard is connected. This is recommended when the CPU needs the layout code (i.e. a SUN CPU) and the  
keyboard doesn't have an explicit layout code (i.e. some Windows keyboards). To do this, manually set the UNIMUX-USBV-4  
USB KVM switch to indicate the international keyboard identification number to the CPU using the following procedure;  
1. Connect the keyboard to be used to the UNIMUX-USBV-4 USB KVM switch  
2. Enter Command Mode  
3. Type Lxx, where xx is the number from the list below that corresponds to the desired country code  
4. Exit Command Mode  
5. Reboot the CPU connected to the UNIMUX-USBV-4 USB KVM switch.  
Country Codes  
00  
01  
02  
03  
Auto Detect  
Arabic  
Belgian  
Canadian-  
Bilingual  
Canadian-French  
Czech Republic  
Danish  
Finnish  
French  
German  
Greek  
Hebrew  
Hungary  
13  
14  
15  
16  
International (ISO) 26  
Swedish  
Italian  
Japan (Katakana)  
Korean  
27  
28  
29  
Swiss/French  
Swiss/German  
Switzerland  
04  
05  
06  
07  
08  
09  
10  
11  
12  
17  
18  
19  
20  
21  
22  
23  
24  
25  
Latin American  
30  
Taiwan  
Turkish  
UK  
US  
Yugoslavia  
Netherlands/Dutch 31  
Norwegian  
Persian (Farsi)  
Poland  
32  
33  
34  
Portuguese  
Russia  
Slovakia  
Spanish  
Figure 3- Country Codes for international SUN keyboards  
For more on international SUN keyboards, see page 21.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
No Sun Sleep Mode  
PLEASE NOTE: It may be necessary to configure a Sun CPU (most versions) such that the Sleep Mode is not enabled. If  
the Sun CPU goes into sleep mode either automatically or manually, the user must reboot the Sun CPU in order to  
resume use of the Sun CPU.  
To disable the Sleep Mode, perform the following steps:  
1. Select "Power Manager"  
2. Look for "Device Idle Time Before Power Saving Starts"  
3. Select "Always ON"  
4. Look for "Override Device Idle Time For:"  
5.Make sure neither "Monitors " nor "Disks" are selected.  
Mice and Trackballs with MACs  
The UNIMUX-USBV-4 USB KVM switch can be configured to enable full functionality between mice and trackballs having two or  
more buttons and USB MAC CPUs. By default, the ports on the UNIMUX-USBV-4 USB KVM switch are configured for use with  
WINDOWS and SUN CPUs and have no special translation for using multi-function mice and trackballs when a MAC CPU is  
connected. Using the commands <M> + <x> (x = port number), or <W> + <x> in Command Mode (page 6), either enable or  
disable this feature as needed for each port.  
NOTE: Be sure to re-configure port for connection to a WINDOWS or SUN CPU if a MAC CPU is removed and a  
WINDOWS or SUN CPU is then connected.  
OPTIONAL OSD CONTROL  
OSD superimposes a menu system on the user’s video screen with a list of all connected CPUs. OSD allows CPUs to be named  
(with up to 12 character names). OSD then allows selection of CPUs by that name. Connected CPUs can be listed by name or  
by port number. OSD Search Mode enables the user to type in the first few characters of the CPU's name and the OSD will  
locate it. HELP screens assist with all OSD functions.  
Note: The optional OSD control feature is only available on the 4 port switch.  
Security Option  
The security option in the OSD Control of the UNIMUX-USBV-4O USB KVM switch enables an administrator to control access to  
CPU ports for each user. Up to 63 users can be created. These users have controlled access to any CPU. Only the  
administrator can activate or deactivate the security features on each user port. Finally, the administrator can set a maximum idle  
time value after which the current user will be logged out and the login screen displayed again. This time out does not function  
while the OSD is active. The current security status, idle time out, and scan dwell time are all saved and will be restored  
whenever power to the switch is cycled OFF, then ON. In the event the administrator password is lost or forgotten, to reset the  
administrator’s password call NTI and have the device serial number of the UNIMUX-USBV-4O USB KVM switch available.  
Enabling The Security Feature  
To enable the security feature the administrator must first enter Command Mode from the keyboard using the <Ctrl> + <`> (accent  
key). The OSD menu will automatically appear on the monitor. This provides a visual way to control the UNIMUX-USBV-4O  
USB KVM switch using the keyboard and mouse.  
The administrator will activate security when logging in by typing <Ctrl> +  
<M> , then <A>, and then <Y>. The administrator will then be prompted  
for a valid administrator username and password (see Fig. 4).  
The factory administrator login settings are:  
default user name = ADMINISTRATOR  
default password = ADMINISTRATOR  
Note: The username for the administrator cannot be changed  
from "ADMINISTRATOR".  
Figure 4- User Login screen  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Once logged-in, follow the instructions on page 10 for setting up users and changing the password. Once the password is setup,  
if it is lost or forgotten the administrator will have to contact NTI for assistance on clearing the password and set it up again. The  
administrator can setup each of the users and the limitations of their use of the individual CPUs within the Administration Mode.  
When a standard user powers up the system a security screen may appear as setup by the administrator. The user will  
need to login to the system by following the instructions below for the USER LOGIN. If the user does not know the appropriate  
user name and password (setup by the administrator), contact the system administrator for this information. Once logged-in a  
user can follow the Command Mode functions described on page 12 to control the system of CPUs within the limitations as  
determined by the administrator.  
User Login Mode  
User Login Mode requires a user to login with a user name and password from the list created by the administrator. With security  
enabled, the user will be locked to the current CPU and the login screen will remain on the monitor until the user logs in.  
Function:  
Keystroke:  
A-Z  
0-9  
(Type any upper or lower case  
alphabetical or numeric character)  
Add a character to the  
user name/password  
A-Z  
Shift  
or  
+
Remove previous character  
from the user name/password  
Backspace  
If the password submitted is incorrect, the user will not be  
able to proceed.  
Enter  
Submit user name/password  
If the password submitted is correct, the user will proceed  
to Normal Mode.  
Exit USER LOGIN and return  
to previous mode. This function  
is only available if security is  
not currently enabled.  
Esc  
ADDITIONAL MODES AVAILABLE WITH SECURITY  
Administration Mode  
To enter the Administration Mode: press <A> from the Maintenance Mode menu. (See page 17 for Maintenance Mode menu.)  
The Administration Mode (see Fig. 5) can be accessed only when security features are activated and the administrator is logged-  
in. Users other than the administrator are not allowed to enter the Administration Mode.  
If a different user is logged-in, log-out by pressing <Q> from the Maintenance  
Mode menu, then log-in as Administrator. (See page 8, "Enabling The  
Security Feature".)  
Administration Mode allows the administrator to use the following functions:  
Function:  
Keystroke:  
Change the administrator’s  
password  
C
Disable security  
S
U
Enter User Name List Mode  
Figure 5- Administration Mode menu  
(xxx from 002 to 255. ie. t002  
would set the time out period  
for 2 minutes. 000 will disable it. )  
(0-2)  
x
(0-9)  
x
(0-9)  
x
Selects the idle time in minutes  
-
T
X
-
-
Change Alternate Command  
Hot Key  
(See page 12 for details)  
Esc  
Exit Administration Mode and  
return to previous mode  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Administrator Password  
To enter the Administrator Password menu press <C> from the  
Administration Mode menu.  
The Administrator Password menu (see Fig. 6) enables the administrator to  
change his password. Two edit fields are available, one for password, the  
other for verify password. The password can be up to 13 characters in  
length.  
NOTE: The default password for the administrator is  
ADMINISTRATOR.  
Function:  
Keystroke:  
Tab  
Switch between Password and  
Verify Password fields  
Figure 6- Administrator Password screen  
A-Z  
0-9  
(Type any upper or lower case  
A-Z  
Add character to password string  
or verify password string  
Shift  
or  
+
alphabetical or numeric character)  
Delete previous character in  
edited string  
Backspace  
Save new password. (The  
administrator will be prompted  
for a Yes or No confirmation)  
(If Password string and Verify Password string  
are different, this command will have no effect,  
enabling the administrator to correct the password)  
Enter  
Return to Administration Mode  
Esc  
User Name List  
To enter the User Name List press <U> from the Administration Mode menu.  
The User Name List (see Fig. 7) enables the administrator to see a list of users. The administrator can select either an existing  
user to modify user settings, or an empty record to add a new user.  
Function:  
Keystroke:  
Select previous user in the list  
Select next user in the list  
Page  
Up  
Scroll the list with one page up  
Scroll the list with one page down  
Page  
Down  
Edit selected user settings-  
Enter Edit User Mode  
E
Esc  
Return to Administration Mode  
Figure 7- User Name List  
Download from Www.Somanuals.com.1A0ll Manuals Search And Download.  
Edit User  
To enter the Edit User mode press <E> from the User Name List after selecting a user or an empty record.  
The Edit User mode (see Fig. 7) enables the administrator to:  
-
-
-
add a new user  
remove an existing user  
edit the settings for an existing user  
The Edit User mode contains three edit boxes and a check box list of up to  
4 check boxes representing the User Access List (list of the CPU port(s)  
the user has access rights to).  
The first edit box is used to edit the user name. The next two edit boxes  
are used to input the password twice (in order to verify it was typed  
correctly). The password can be up to 13 characters in length.  
The check boxes are usea usea ancess rstrts.]TJ0 -1.1467 TD-0.0017 Tc0 00289Tw[(T)-1.9(ye user h-6.6(w)14.58()-5.72(ll onl)12.36 )-6.6(ih  
11  
Alternate Command Hot Key  
To enable the administrator to assign a key in addition to the <`> (accent key) to use with <Ctrl> to enter into OSD Command  
Mode, an Alternate Command Hot Key option is provided. The default factory setting for this option is <`> (disabling the option).  
To select an Alternate Command Hot Key, press <X> from Administration Mode menu (page 9). A window will open and the  
administrator will be prompted to press a key. After pressing the key, a confirmation message will appear. The administrator  
should press <Y> (Yes) to validate the key as the Alternate Command Hot Key, or <N> (No) to select another key. Pressing  
<Esc> will return to the Administration Mode menu.  
Only the administrator is allowed to set or change the Alternate Command Hot Key. This function must be set individually for each  
of the USB User Device ports on the UNIMUX USBV-4 USB KVM switch .  
Note: The Alternate Command Hot Key does not replace the <`> (accent) key, it just works as another way to enter into Command  
Mode. After setting it, the user can enter into Command Mode either with <Ctrl> + <`> or with <Ctrl> + <Alternative Command Hot  
Key> combination. To disable it, the administrator should set <`> as the Alternate Command Hot Key.  
USER ACCESS FUNCTIONS  
Command Mode  
In order to control the switch with the keyboard, Command Mode must be enabled. To enable Command Mode from the  
keyboard:  
Press  
(ACCENT  
KEY)  
~
Ctrl  
+
`
All the status lights on the keyboard will illuminate to indicate that Command Mode is enabled. At this point, the Command Mode  
menu will be displayed.  
The Command Mode menu (see Fig. 8) lists all CPUs by name and port number. When the Command Mode main menu is  
displayed, the first displayed port in the list will be the port the current user is connected to, followed by the next three  
consecutively numbered ports. (Alternatively the list may be alphabetically sequential- see Maintenance Mode on page 17 to  
toggle sort method.) The names of accessible ports are displayed with white characters. If Security is activated, the access  
rights for the user logged-in may not include all ports. Names of restricted access ports are displayed in blue.  
An arrow to the left of a port number in the list indicates the port the user is currently connected to. From left to right, the columns  
display the following:  
Type of  
CPU  
Port  
Power  
Status  
Number  
Port Name  
Port Number  
Port Name  
Type of CPU connected (USB)  
Power Status of the CPU (ON/OFF)  
Figure 9- User level Command Mode  
NOTE: While in Command Mode, the numbers on the NUM PAD on the keyboard are not active. If numbers are required  
while in Command Mode, use the numbers on the main key bank.  
Download from Www.Somanuals.com.1A2ll Manuals Search And Download.  
The list below describes the command functions available from the keyboard within the OSD mode of control after entering into  
Command Mode:  
Function:  
Keystroke:  
Select the previous port  
Select the next port  
Enable/disable Scan Mode  
Enable/disable Broadcast Mode  
Ctrl  
Ctrl  
Ctrl  
S
B
E
T
+
+
+
+
+
Enter Edit Mode  
(Only available if administrator  
is logged in)  
Ctrl  
Ctrl  
Enter Change Settings Menu  
Enter Maintenance Mode  
M
F1  
Display Help Menu  
Figure 10- Additional Command Mode options  
Home  
Select the first port on the switch  
Note: When the user presses and holds the  
<Ctrl> key from the first Command Mode  
image, the additional options of  
Maintenance, Port, and Edit will appear.  
(See Fig.10)  
End  
Select the last port on the switch  
Select a specific port  
(0-9)  
x
(0-9)  
x
(Pxx would be P01, P02, etc.)  
Ctrl  
-
P
-
+
Enter Search Mode, add a character  
to search string and select the CPU’s  
name that matches best.  
A-Z  
0-9  
(Type any alphabetical or numeric character)  
Note: use is case sensitive  
Enter  
Switch to a selected port  
Update Configuration  
Display port information  
Exit Command Mode  
(Use this command to update the information  
Tab  
describing the structure of the cascaded  
switches. Used if a slave is powered-ON or  
OFF at any time after initial startup.)  
Ctrl  
+
(Display information about the selected port. When pressed,  
a window displays the port name and its position in the configuration  
structure by level and port number.)  
F3  
Esc  
Download from Www.Somanuals.com.1A3ll Manuals Search And Download.  
The mouse can also be used to control the UNIMUX-USBV-4O USB KVM switch Command Mode within the menu.  
The scroll wheel can be used to scroll through the ports list.  
The mouse cursor can be moved to the Sharing, Scan and Broadcast fields where the user can click on  
the left mouse button to toggle that indicator.  
Ports listed on the screen can be selected by moving the cursor onto a port and clicking.  
NOTE: Exit Command Mode to type to a CPU. To exit Command Mode, press <Esc> or click the “ESC” command on the  
screen with the mouse.  
Scan Mode  
To activate Scan Mode press <Ctrl> + <S> from the Command Mode menu.  
Scan Mode enables the user to scan through selected ports and to have full device control of the connected port. From the  
Change Settings menu (see page 15) the user can edit the list of ports that can be scanned. A port is skipped from the scan cycle  
if one of the following conditions is true:  
- the port is not in the scan list  
- security mode is enabled and the user does not have access rights to the port  
- the CPU connected to the port is OFF  
When switching to a new port the port name is displayed by OSD in the left upper corner of the monitor for 5 seconds or until a  
key is pressed or the mouse is moved, whichever comes first. The scan dwell time is programmable from 2 to 255 seconds  
(default time-out period is 5 seconds). When the user uses the mouse or keyboard the scanned port becomes active and scanning  
is stopped. The switch will resume scanning after a period of user inactivity determined by the scan dwell time. See Change  
Settings Menu on page 15 for configuring the scan dwell time.  
NOTE: The scan dwell time set by the user only effects that user and has no effect on other switch users.  
NOTE: The keyboard and mouse must remain idle for the full scan dwell time before the switch selects the next active  
port.  
Broadcast Mode  
To activate Broadcast Mode press <Ctrl> + <B> from the Command Mode menu.  
Broadcast Mode enables the user to type characters to more computers simultaneously. From the Change Settings menu (see  
page 15) the user can edit the list of ports that receive data in Broadcast Mode. A port doesn’t receive broadcast data if one of the  
following conditions is true:  
- the port is not in the Broadcast Mode list  
- Security Mode is enabled and the user does not have access rights to the port  
NOTE: The user must type somewhat slowly when in Broadcast Mode (less than 20 wpm) and cannot use the  
<Backspace> key.  
Normal Mode  
When the UNIMUX-USBV-4 USB KVM switch is not in Command, Scan, or Broadcast mode and the OSD control is not active on  
the monitor, the user is in Normal Mode, controlling the CPU to which the user is connected through the UNIMUX-USBV-4 USB  
KVM switch.  
Edit Mode  
To activate Edit Mode press <Ctrl> + <E> from the Command Mode menu.  
Edit Mode allows only the administrator to modify the names of the CPUs connected to the switch. Names of CPUs can be up to  
12 characters in length. Characters typed can be upper or lower case. After changes have been made the administrator will be  
prompted by the menu to save the changes. Answer "Y" to save changes and answer "N" to continue using previously entered  
port names.  
Function:  
Keystroke:  
Move cursor one position  
to the right  
Move cursor one position  
to the left  
Download from Www.Somanuals.com.1A4ll Manuals Search And Download.  
Edit Mode (Cont'd)  
Function:  
Keystroke:  
Move cursor to the  
previous port  
NOTE: If a change has been made, using the up or  
down arrow will also prompt the user to save any  
changes.  
Move cursor to the  
next port  
When finished making changes in Edit Mode, press <Esc> and a prompt will appear to press either <Y> to save the changes or  
<N> to continue making changes without saving the changes just made.  
Change Settings  
To enter the Change Settings menu (see Fig. 11) press <Ctrl>+<T> from the Command Mode menu.  
The list below describes the Change Settings menu functions available from the keyboard:  
Function:  
Keystroke:  
Go to Broadcast Mode Configuration  
B
Go to Scan Mode Configuration  
S
L
Go to Language Selection Menu  
(Option only available if the  
administrator is logged in)  
Change the scan dwell time period  
T
Configure ports for MAC or non-  
MAC CPUs (Administrator only)  
M
Figure 11- Change Setting menu  
Exit from Change Settings  
Return to Command Mode  
Esc  
When the <T> is pressed, an edit field showing the actual value of the scan dwell time is displayed at the bottom of the Change  
Settings menu. The user can introduce a new value for scan dwell time and press <Enter> to save it or <Esc> to exit. Any value  
between 002 and 255 (seconds) is acceptable.  
Download from Www.Somanuals.com.1A5ll Manuals Search And Download.  
Broadcast Mode Configuration  
To enter the Broadcast Mode Configuration menu press <B> from the Change Settings menu (see Fig. 10).  
The Broadcast Mode Configuration menu (see Fig. 12) enables the user to select specific ports to be active in Broadcast Mode.  
Only the selected ports will receive keyboard messages in Broadcast Mode.  
A check list with all the port numbers will be displayed in the window.  
unchecked box = the corresponding port is not in the broadcast list  
checked box = the corresponding port is in the broadcast list  
The user can toggle the state of the selected check box by pressing  
<Spacebar> or clicking the left mouse button.  
press <S> to check all of the ports  
press <C> to uncheck all of the ports  
The selected port is highlighted with a green bar. To select another port, the  
user can use the arrow keys or mouse movement. The name of the selected  
port is displayed at the bottom left of the menu.  
When <Esc> is pressed the display will return to the Change Settings menu.  
The broadcast selection list is automatically saved.  
Figure 12- Select ports for broadcasting  
Scan Mode Configuration  
To enter the Scan Mode Conf  
16  
MAC Ports Configuration  
NOTE: The CONFIGURE MAC PORTS option will be in blue text in the Change Settings menu and will only be accessible  
if the administrator is logged in.  
MAC Ports Configuration menu enables the administrator to select specific ports to be connected to MAC CPUs for passing  
mouse information to the MAC CPUs. This is useful when the user wants to use mouse drivers provided by the mouse vendor,  
which allows the use of programmable functions for each button. Ports should be configured at installation time or whenever  
necessary. After setting, the configuration is stored in non-volatile memory and will be retrieved whenever the switch is power  
ON. When the port is connected to a Windows or SUN CPU, this configuration SHOULD BE DISABLED. By default, all ports are  
configured as non-MAC CPUs (Windows and SUN).  
NOTE: If a port is configured as connected to a non-MAC CPU, but is in fact connected to a MAC CPU, the mouse will  
still work as a generic mouse. No special functions provided by software drivers will be available.  
To enter the MAC Ports Configuration menu, the administrator must press <M> from the Change Settings menu, described on  
page 15.  
A check list with all the ports numbers preceded by a check-box will be displayed in the window.  
unchecked box = the corresponding port is set as connected to a non-MAC CPU  
checked box = the corresponding port is set as connected to a MAC CPU  
In order to change the status of a port, the administrator has to first select the port. The selected port is highlighted with a green  
bar.  
To select another port, the administrator can use the arrow keys or mouse movement. The name of the selected port is displayed  
at the bottom left of the menu, right above the yellow bar.  
The administrator can toggle the state of the selected check box by pressing the <Spacebar> or clicking the left mouse button.  
Press <S> to check all the ports  
Press <C> to uncheck all the ports  
When <Esc> is pressed, the display will return to the Change Settings menu. The list is automatically saved.  
The settings apply to all users of the switch.  
Maintenance Mode  
To enter Maintenance Mode (see Fig. 13) press <Ctrl>+<M> from the Command Mode menu.  
Maintenance Mode enables a user to customize the On Screen Display to their requirements. Also, the Security Mode can be  
activated/deactivated from this menu.  
Function:  
Keystroke:  
Reset all of the port names  
R
Toggle between numeric and  
alphabetic listing of ports  
L
Move On Screen Display (OSD)  
menu up on monitor  
Move OSD menu down on  
monitor  
Figure 13- Maintenance Mode menu  
Move OSD menu to the right  
Download from Www.Somanuals.com.1A7ll Manuals Search And Download.  
Maintenance Mode (Cont'd)  
Function:  
Keystroke:  
Move OSD menu to the left  
Make OSD menu taller  
Make OSD menu shorter  
T
S
NOTE: If activating security features, the user will be  
prompted for a “Y” (yes) or “N” (no) to confirm the menu  
choice, at which point the user will be asked for a  
username and password before continuing. Only the  
administrator can activate the security features.  
Activate security features.  
Present only when security is  
available but not active.  
A
Enter Administration Mode.  
Option present only when administrator  
is logged in.  
Log current user out and return  
to User Login Mode.  
(Only displayed when security is active)  
Q
Save OSD window parameters  
for the port  
Enter  
Return to Command Mode  
Esc  
NOTE: Based on different scan rates, the OSD window may appear in different areas of the monitor as different CPU  
ports are selected. The Maintenance Mode functions allow placement of the window in a particular area of the monitor  
and the window will return there when the UNIMUX-USBV-4O USB KVM switch is reconnected to that particular CPU  
(provided the parameters are saved before exiting Maintenance Mode).  
Search Mode  
Search Mode is enabled by typing any alphabetical or numeric characters while in the Command Mode menu (see page 13).  
Search Mode allows the user to enter and maneuver through a list of CPU names. The CPU name best matching the characters  
typed is selected. The list of CPUs may also be searched for a specific (or similar) name. The following commands are valid when  
the search option has been invoked from Command Mode.  
Function:  
Keystroke:  
Erase previous character  
in search name  
Backspace  
Add a character to the search  
string and select the best  
matching CPU name  
A-Z  
0-9  
(Type any alphabetical or numeric character)  
Exit Search Mode, return to  
Command Mode  
Enter  
Esc  
or  
Download from Www.Somanuals.com.1A8ll Manuals Search And Download.  
Help Mode  
To enter Help Mode press the <F1> key from the Command Mode menu (see page 13).  
Help Mode displays a list of commands with a short explanation of their function. The following options allow the user to quickly  
obtain information on any command.  
Function:  
Keystroke:  
Page  
Up  
View the previous page of help  
if available  
Page  
Down  
View the next page of help  
if available  
Exit HELP and return to previous  
mode  
Esc  
F3- Display Information  
To display information about a selected port, pressing the <F3> key from within the Command Mode main menu will cause a  
window to open. The window will show the name of the port and its position in the system structure, level by level. This is most  
useful when cascading switches (for Cascading see page 22). An example of this structure might be  
LEVEL 1 : PORT 5  
LEVEL 2 : PORT 3  
This means that the CPU connected through this port is actually connect through Port 5 of the master switch (Level 1), and  
through port 3 of the slave connected to port 4 (Level 2). See Fig. 14 below.  
U
S
E
R
1
U
S
O
E
R
P
O
R
T
S
U
N
I
A
M
U
X
L
E
V
E
L
1
M
S
T
E
R
C
P
U
P
R
T
5
U
S
E
R
P
O
R
T
S
U
N
I
M
U
X
E
L
E
V
E
L
2
S
L
A
V
C
P
U
P
O
R
T
S
C
P
U
P
O
R
T
3
C
P
U
Figure 14- Information provided by the F3 command  
Download from Www.Somanuals.com.1A9ll Manuals Search And Download.  
KEYBOARDFEATURES  
The keyboard configuration of each CPU is saved in the NTI UNIMUX-USBV-4 USB KVM switch. For example, if the CPU  
attached to Port 2 had CAPS LOCK and NUM LOCK selected the last time that CPU was accessed, then they will automatically  
be set when that CPU is accessed again.  
Keyboard-To-Computer Translation  
(See Fig. 15 on page 21 for reference.)  
The NTI UNIMUX-USBV-4 USB KVM switch enables a mixture of otherwise incompatible peripheral computer components to be  
connected together. This is accomplished by performing keyboard-to-computer translations automatically (i.e. translate a MAC  
keyboard and mouse to a Windows type CPU). The chart below shows the capabilities of devices controlling certain CPU types.  
Translation Capabilities  
CPU  
Sun  
Mac  
Windows  
Device  
Full functionality  
Extra keys emulation  
Extra keys emulation  
Full functionality  
Power key emulation  
Full functionality  
Full functionality  
Full functionality  
Full functionality-except  
Application Key  
Sun Keyboard  
AT101 Keyboard  
Mac keyboard  
Apple Pro Keyboard  
Extra keys emulation  
Extra Keys not supported Full functionality  
(Eject, Mute, Volume+,  
Volume-)  
Sun Mouse  
Wheel Mouse  
Apple Mouse  
Full functionality  
Full functionality  
Right button emulation  
Full functionality  
Full functionality  
Full functionality  
Full functionality  
Full functionality  
Right button emulation  
Translation Tables  
Use the charts below to type SUN’s additional keys with Win95 and Apple keyboards:  
SUN Extra Keys  
WINxx or Mac Keyboards  
Space Bar + F1  
Sun Extra Keys  
Stop  
Power Key Emulation  
Win95 Keyboards  
Mac CPU  
Sun CPU  
Space Bar + F2  
Space Bar + F3  
Again  
Props  
SB+RT Arrow  
Power  
Power  
Space Bar + F4  
Undo  
Space Bar + F5  
Front  
Space Bar + F6  
Copy  
Space Bar + F7  
Open  
Space Bar + F8  
Paste  
Space Bar + F9  
Find  
Cut  
Help  
Compose  
Volume +  
Volume -  
Mute  
Mouse Click Equivalents  
Space Bar + F10  
Space Bar + F11  
Space Bar + F12  
Space Bar + Up Arrow  
Space Bar + Down Arrow  
Space Bar + Left Arrow  
To emulate right-button click using an Apple 1-button  
mouse, hold down the CMND key (key with open  
apple insignia) while pressing the mouse button.  
Download from Www.Somanuals.com.2A0ll Manuals Search And Download.  
i
c
a
p
E
s
c
N
L
u
m
B
a
c
k
s
p
a
c
e
o
c
k
T
a
b
E
n
t
e
r
C
a
p
s
L
o
c
k
S
h
i
f
t
S
h
i
f
t
E
n
t
e
r
C
t
r
l
A
l
t
A
l
t
C
t
r
l
W
i
n
d
o
w
s
U
S
B
K
e
y
b
o
a
r
d
n
l
u
m
o
c
k
d
e
l
e
t
e
g
y
o
~
`
K
e
t
a
b
r
e
t
u
r
n
c
a
p
s
L
o
c
k
s
h
i
f
t
a
l
t
e
n
t
e
r
c
o
n
t
r
o
l
o
p
t
i
o
n
P
o
e
w
r
k
e
y
o
w
s
L
o
H
e
l
p
C
p
o
d
y
a
o
n
U
i
A
n
g
S
t
o
p
r
P
o
s
p
r
F
n
o
i
t
n
O
d
p
e
n
C
F
t
u
a
P
e
s
t
t
C
m
o
o
-
U
s
U
p
N
e
B
S
K
S
o
e
a
y
d
r
b
S
h
i
f
t
g
y
i
o
W
n
d
K
e
C
a
p
s
l
o
c
k
A
l
t
a
B
c
k
s
p
a
c
e
M
a
K
e
e
t
y
M
a
K
e
e
t
y
l
S
h
i
f
Figu
o
w
s
L
o
International Sun Keyboards  
The UNIMUX-USBV-4 USB KVM switch can recognize inte
Sun keyboard, follow this procedure:  
r
y
i
K
W
n
e
d
1. Power-OFF the CPU from the UNIMUX-USBV-4 USB KV
2. Connect the international keyboard to be used to the UNIMUX-USBV-4 USB KVM switch  
3. Power-ON the CPU to the UNIMUX-USBV-4 USB KVM switch  
t
It is also possible to configure the UNIMUX-USBV-4 USB KVM switch to emulate a specific international Sun keyboard gardless  
of what actual keyboard is connected. This is recommended when the CPU needs the layout code (i.e. a SUN CPU) and the  
keyboard doesn't have an explicit layout code (i.e. some Windows keyboards). To do this, manually set the UNIMUX-USBV-4  
USB KVM switch to indicate the international keyboard identification number to the CPU by following the instruction on page 7 (for  
switches without OSD feature) or on page 16 (for switches with OSD feature).  
e
r
i
C
o
n
t
l
a
e
i
t
a
c
k
P
r
i
n
e
r
E
n
t
y
c
k
T
a
b
21  
a
p
s
A
L
o
L
o
c
k
T
F
n
o
c
t
n
e
t
r
r
f
o
e
a
B
b
S
y
s
R
CASCADING  
The UNIMUX-USBV-4O USB KVM switch can be expanded to access up to 128 CPUs by cascading multiple units together. As  
many switches as there are CPU ports may be connected to a UNIMUX-USBV-4O USB KVM switch. Single user and multi-user  
UNIMUX switches may be connected downstream (see Figs.16 and 17). The first switch in a cascaded system is referred to as  
the "master", while all downstream switches are referred to as "slaves". The only additional hardware required to cascade  
switches is a set of device and monitor cables for each “SLAVE UNIT” (see MATERIALS on page 1). All CPUs and switches can  
then be controlled by users using OSD commands with Command Mode.  
Note: The UNIMUX 4 port USB KVM switch must have OSD installed to use cascading.  
Note: Cascading is not an option in the UNIMUX-USBV-2 2 port USB KVM switch.  
U
S
E
R
1
U
S
E
R
P
O
R
T
U
N
I
M
U
X
-
1
X
4
M
A
S
T
E
R
C
P
U
P
O
R
T
S
U
S
B
V
E
X
T
-
x
x
-
M
M
U
S
B
V
E
X
T
-
x
x
-
M
M
U
S
B
V
E
X
T
-
x
x
-
M
M
U
S
B
V
E
X
T
-
x
x
-
M
M
U
S
E
R
P
O
R
T
U
S
E
R
P
O
R
T
U
S
E
R
P
O
R
T
U
S
E
R
P
O
R
T
U
N
I
M
U
X
-
1
x
4
U
N
I
M
U
X
-
1
x
4
U
N
I
M
U
X
-
1
x
4
U
N
I
M
U
X
-
1
x
4
S
L
A
V
O
E
S
L
A
V
E
S
L
A
V
O
E
S
L
A
V
E
C
P
U
P
R
T
S
C
P
U
P
O
R
T
S
C
P
U
P
R
T
S
C
P
U
P
O
R
T
S
U
S
B
V
E
X
T
-
x
x
-
M
M
U
S
B
V
E
X
T
-
x
x
-
M
M
U
S
B
V
E
X
T
-
x
x
-
M
M
U
S
B
V
E
X
T
-
x
x
-
M
M
(
4
C
A
B
L
E
S
)
(
4
C
A
B
L
E
S
)
(
4
C
A
B
L
E
S
)
(
4
C
A
B
L
E
S
)
C
P
U
1
3
C
P
U
1
6
C
P
U
1
C
P
U
4
C
P
U
5
C
P
U
8
C
P
U
9
C
P
U
1
2
Figure 16- Cascaded UNIMUX-USBV-4O USB KVM switches  
Download from Www.Somanuals.com.2A2ll Manuals Search And Download.  
Limitations  
The front panel buttons are only used to operate standalone switches. To control a cascaded network of switches, only the OSD  
commands within Command Mode will be recognized.  
Users connected to accessible ports on downstream slaves (i.e. ports not connected to the master, as in the case of multi-user  
slaves) will not be able to control switches or CPUs connected upstream. Only control over CPUs and slaves downstream from  
a user's connection point will be enabled. (See Fig. 17)  
U
S
E
R
1
U
S
E
R
2
U
S
E
R
3
U
S
E
R
4
U
S
E
R
P
O
R
T
U
S
E
R
P
O
R
T
U
S
E
R
P
O
R
T
U
S
E
R
P
O
R
T
U
U
s
s
e
e
r
r
s
s
5
1
-
-
8
4
o
h
n
a
l
y
h
a
v
e
a
c
c
e
s
s
t
o
C
P
U
s
2
5
-
4
0
.
U
N
I
M
U
X
-
1
X
4
U
N
I
M
U
X
-
1
X
4
U
N
I
M
U
X
-
1
X
4
U
N
I
M
U
X
-
1
X
4
v
e
a
c
c
e
s
s
t
o
a
l
l
C
P
U
s
M
A
S
T
E
R
M
A
S
T
E
R
M
A
S
T
E
R
M
A
S
T
E
R
C
P
U
P
O
R
T
S
C
P
U
P
O
R
T
S
C
P
U
P
O
R
T
S
C
P
U
P
O
R
T
S
(
T
O
U
S
E
R
P
O
R
T
2
O
N
(
T
O
U
S
E
R
P
O
R
T
3
O
N
(
T
O
U
S
E
R
P
O
R
T
4
O
N
S
L
A
V
E
S
1
-
4
)
S
L
A
V
E
S
1
-
4
)
S
L
A
V
E
S
1
-
4
)
U
S
B
V
E
X
T
-
x
x
-
M
M
U
S
B
V
E
X
T
-
x
x
-
M
M
U
S
E
R
6
U
S
E
R
8
U
S
E
R
5
U
S
E
R
7
U
S
B
V
E
X
T
-
x
x
-
M
M
U
S
B
V
E
X
T
-
x
x
-
M
M
(
P
U
S
E
R
(
P
U
S
E
R
(
P
U
S
E
R
(
P
U
S
E
R
O
R
T
1
)
O
R
T
1
)
O
R
T
1
)
O
R
T
1
)
U
S
E
R
P
O
R
T
S
U
S
E
R
P
O
R
T
S
U
S
E
R
P
O
R
T
S
U
S
E
R
P
O
R
T
S
U
N
I
M
U
X
-
4
X
8
U
N
I
M
U
X
-
4
X
8
U
N
I
M
U
X
-
4
X
8
U
N
I
M
U
X
-
8
X
1
6
S
L
A
V
O
E
S
L
A
V
O
E
S
L
A
V
O
E
S
L
A
V
E
C
P
U
P
R
T
S
C
P
U
P
R
T
S
C
P
U
P
R
T
S
C
P
U
P
O
R
T
S
U
S
B
V
E
X
T
-
x
x
-
M
M
U
S
B
V
E
X
T
-
x
x
-
M
M
U
S
B
V
E
X
T
-
x
x
-
M
M
U
S
B
V
E
X
T
-
x
x
-
M
M
(
8
C
A
B
L
E
S
)
(
8
C
A
B
L
E
S
)
(
8
C
A
B
L
E
S
)
(
1
6
C
A
B
L
E
S
)
C
P
U
2
5
C
P
U
4
0
C
P
U
1
C
P
U
8
C
P
U
9
C
P
U
1
6
C
P
U
1
7
C
P
U
2
4
Figure 17- Cascaded configuration with multi-user slaves  
Cable Connections  
The same cable used to connect a CPU to the UNIMUX is used to connect two UNIMUX switches together- USBVEXT-xx-MM.  
No other cables will be necessary. To connect a slave to a master  
1. Connect the USB-A-male end of the USBVEXT-xx-MM to the USER 1 port on the slave.  
2. Connect the 15HD male at the same end of the USBVEXT-xx-MM cable to the MONITOR 1 port on the slave.  
3. Connect the USB-B-male end of the USBVEXT-xx-MM to the CPU 1 port on the master.  
4. Connect the 15HD male at the same end of the USBVEXT-xx-MM to the VIDEO 1 port on the master.  
Repeat this procedure for each USER and MONITOR port on the slave that is desired to be controlled through the master. Any  
USER and MONITOR ports that do not get connected to the master can be connected to by users. Users connected to a slave  
downstream from the master will control only the CPUs directly connected to that slave switch (i.e. users 5 and 6 in fig. 17 above  
can only control CPUs 25-40).  
Download from Www.Somanuals.com.2A3ll Manuals Search And Download.  
R
E
A
R
V
I
E
W
O
F
M
A
S
T
E
R
U
N
I
M
U
X
-
U
S
B
V
-
4
O
R
N
E
T
W
O
R
K
T
E
C
H
N
O
L
O
G
I
E
S
I
N
C
O
R
P
O
R
A
T
E
D
1
2
7
5
D
a
n
n
e
r
D
r
i
v
e
,
A
u
r
o
r
a
O
h
i
o
4
4
2
0
2
3
3
0
-
5
6
2
-
7
0
7
0
w
w
w
.
n
t
i
1
.
c
o
m
N
T
I
M
O
N
I
T
O
R
V
I
D
E
O
4
V
I
D
E
O
3
V
I
D
E
O
2
V
I
D
E
O
1
U
S
B
D
E
V
I
C
E
S
C
P
U
4
C
P
U
3
C
P
U
2
C
P
U
1
5
V
2
D
C
A
+
-
U
S
E
R
4
U
S
E
R
3
U
S
E
R
2
U
S
E
R
1
U
S
E
R
4
U
S
E
R
3
U
S
E
R
2
U
S
E
R
1
R
R
N
T
I
N
T
I
C
P
U
1
6
C
P
U
1
6
M
M
O
O
N
N
I
I
T
T
O
O
R
R
3
4
M
M
O
O
N
N
I
I
T
T
O
O
R
R
1
2
M
M
O
O
N
N
I
I
T
T
O
O
R
R
3
4
M
M
O
O
N
N
I
I
T
T
O
O
R
R
1
2
R
S
2
3
2
R
S
2
3
2
Figure 18- Cascaded switch cable connections  
Operating Cascaded Switches  
Immediately after powering-ON the Master switch, the following splash screen will display on the monitor:  
24  
All the downstream switches should be powered ON before pressing any keyboard key. If there are USB extenders connected,  
they should also be powered ON. An extra time of about 5 seconds after powering-ON the last unit may be needed to complete  
the USB enumeration process. If the switch is a standalone unit (no downstream switches connected), the keyboard key could be  
pressed immediately.  
When a keyboard key is pressed, the master switch will start the process of detecting the configuration. This could take several  
seconds, depending on how many switches are connected together. When configuration update is ready, the splash screen  
disappears and the system is ready to operate. (If security mode is activated, the login window will be displayed on the screen).  
The update-configuration function can be recalled at any time by entering into Command Mode and pressing the <Ctrlt> + <Tab>  
keys  
Note: The front panel buttons are used to operate only standalone switches. To operate a cascaded network of switches  
use only OSD commands from Command Mode (see page 12).  
After completing the configuration detection, the splash screen is turned OFF and the switches can be operated. All configuration  
can be controlled from the keyboard, mouse and monitor through OSD menus (page 8).  
Option not available on 2 port switches.  
DDC Support (Optional)  
DDC information allows the CPU to automatically select the optimal resolution for the monitor by receiving, at power up,  
information from the monitor concerning its resolution specifications.  
When DDC Support is installed, the DDC information is acquired from the monitor by the UNIMUX switch when the UNIMUX is  
powered-up. A monitor with DDC support must be connected to MONITOR for this to occur. The DDC information will be  
made available at every CPU port.  
The DDC information can also be acquired by pressing the DDC button located on the front of the switch (see page  
2, item 10). This button allows the monitor configuration to be changed without powering down the switch.  
Note: In order for the CPU to correctly receive the DDC information from the switch at boot-up, the switch  
must be powered up before all attached CPUs.  
TECHNICAL SPECIFICATIONS  
USB Type B  
USB Type A  
VGA Video  
Pin #  
Signal  
+VCC  
- DATA  
+DATA  
GND  
Pin #  
Signal  
Pin # Signal  
Pin # Signal  
1
2
3
4
1
2
3
4
+VCC  
- DATA  
+DATA  
GND  
1
2
3
4
5
6
7
8
RED  
GREEN  
BLUE  
ID2  
TST  
RED GND  
GREEN GND  
BLUE GND  
9
NC  
GND  
ID0  
ID1  
HS  
10  
11  
12  
13  
14  
15  
VS  
ID3  
Mating face of a 15HD female  
VGA VIDEO  
Mating face of a USB Type B Female  
Mating face of a USB Type A Female  
4
3
5
2
1
2
3
1
4
10  
14  
9
8
6
7
3
4
1
2
15  
13 12 11  
Barrel  
Power Connector  
5VDC @ 2.0A OUTPUT  
(Outside  
barrel)  
(Inside  
barrel)  
2.1 mm x 5.5 mm Female  
Download from Www.Somanuals.com.2A5ll Manuals Search And Download.  
TROUBLESHOOTING  
1. Verify all cables are securely connected and that the installation procedure was carefully followed.  
2. If a CPU seems to be locked up,  
cycle the power to the UNIMUX-USBV-4 USB KVM switch OFF, then ON  
disconnect the "USB DEVICES" keyboard and mouse cables (not the "CPU x" keyboard and mouse) from the UNIMUX-  
USBV-4 USB KVM switch and reconnect them  
reboot the CPU  
If the NTI UNIMUX-USBV-4 USB KVM switch still seems work improperly, help may be found in the Frequently Ask  
(330) 562-7070 and we will be happy to assist in any way we can.  
SERIAL NO.:  
UNIMUX-USBV-4  
UNIMUX-USBV-2  
DATE:  
INSPECTED BY:  
UNIMUX-USBV-4O  
UNIMUX-USBV-4D  
MAN026 Rev 8/19/2003  
Download from Www.Somanuals.com.2A6ll Manuals Search And Download.  

Miele Cooktop CS 1223 User Manual
Miele Cooktop KM 326G User Manual
Milan Technology Switch MIL SM801XX User Manual
Milwaukee Power Hammer 1854 1 User Manual
MTD Cultivator 21A 120R000 User Manual
MTX Audio Car Amplifier TA8502 User Manual
NDC comm Network Router NWH650 User Manual
Niles Audio Speaker CM5MP User Manual
Optoma Technology Projector BM 5001U User Manual
Panasonic CD Player CQ DFX55 User Manual