Napoleon Fireplaces Indoor Fireplace ZCVF36 User Manual

1
INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.  
Conforms to the standard ANSI Z21.91 2004 Ventless Firebox Enclosures for Unvented Room Heaters  
INSTALLATION INSTRUCTIONS FOR THE  
ZERO CLEARANCE VENTLESS FIREBOX ENCLOSURE  
MODEL ZCVF36  
MODEL ZCVF42  
CERTIFIED FOR UNITED STATES USING ANSI METHODS  
WARNING: If the information in these instructions is not followed exactly, a re or  
explosion may result causing property damage, personal injury or death.  
FOR YOUR SAFETY  
Do not store or use gasoline or other ammable vapours and liquids in the vicinity of  
this or any other appliance.  
WHAT TO DO IF YOU SMELL GAS:  
• Do not try to light any appliance.  
• Do not touch any electrical switch.  
• Do not use any phone in your  
building.  
• Immediately call your gas supplier  
from a neighbour’s phone. Follow the  
gas supplier’s instructions.  
• If you cannot reach your gas supplier,  
call the re department.  
Installation and service must be performed by a qualied installer, service  
agency or the gas supplier.  
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada . (705) 721-1212 .  
fax(705)722-6031  
W415-0527/ 09.29.05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
NAPOLEON gas replaces are manufactured under the strict Standard of the world recognized  
ISO 9001:2000 Quality Assurance Certicate.  
NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great  
pride in their work. The burner and valve assembly are leak and test-red at a quality test station. The complete ventless rebox  
enclosure is test-red and thoroughly inspected by a qualied technician before packaging to ensure that you, the customer,  
receives the quality product that you expect from NAPOLEON.  
NAPOLEON GAS FIREPLACE PRESIDENT’S LIFETIME LIMITED WARRANTY  
The following materials and workmanship in your new NAPOLEON ventless rebox enclosure are warranted against defects for as long as you  
own the ventless rebox enclosure. This covers: combustion chamber, heat exchanger, phazer™ logs and embers.  
Electrical (110V and millivolt) components and wearable parts such as blowers, thermal switch, switches, wiring, and remote controls, are covered  
and NAPOLEON will provide replacement parts free of charge during the rst year of the limited warranty.  
Labour related to warranty repair is covered free of charge during the rst year. Repair work, however, requires the prior approval of an author-  
ized company ofcial. Labour costs to the account of NAPOLEON are based on a predetermined rate schedule and any repair work must be done  
through an authorized NAPOLEON dealer.  
CONDITIONS AND LIMITATIONS  
NAPOLEON warrants its products against manufacturing defects to the original purchaser only -- i.e., the individual or legal entity (reg-  
istered customer) whose name appears on the warranty registration card led with NAPOLEON -- provided that the purchase was made  
through an authorized NAPOLEON dealer and is subject to the following conditions and limitations:  
This factory warranty is nontransferable and may not be extended whatsoever by any of our representatives.  
The ventless rebox enclosure must be installed by a licenced, authorized service technician or contractor. Installation must be done in  
accordance with the installation instructions included with the product and all local and national building and re codes.  
This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and parts  
installed from other manufacturers will nullify this warranty.  
This limited warranty further does not cover any scratches, dents, corrosion or discolouring caused by excessive heat, abrasive and  
chemical cleaners nor chipping on porcelain enamel parts, mechanical breakage of PHAZER™ logs and embers.  
In the rst year only, this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship  
provided that the product has been operated in accordance with the operation instructions and under normal conditions.  
After the rst year, with respect to this President’s Limited Lifetime Warranty, NAPOLEON may, at its discretion, fully discharge all obligations  
with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective part(s).  
After the rst year, NAPOLEON will not be responsible for installation, labour or any other costs or expenses related to the reinstallation  
of a warranted part, and such expenses are not covered by this warranty.  
Notwithstanding any provisions contained in this President’s Limited Lifetime Warranty, NAPOLEON’S responsibility under this warranty  
is dened as above and it shall not in any event extend to any incidental, consequential or indirect damages.  
This warranty denes the obligations and liability of NAPOLEON with respect to the NAPOLEON ventless rebox enclosure and any  
other warranties expressed or implied with respect to this product, its components or accessories are excluded.  
NAPOLEON neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of  
this product. NAPOLEON will not be responsible for: over-ring, inadequate ventilation, insufcient makeup air, or negative air pressures  
which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.  
Any damages to the ventless rebox enclosure, combustion chamber, brass trim or other component, due to water, weather damage,  
long periods of dampness, condensation, damaging chemicals or cleaners will not be the responsibility of NAPOLEON.  
The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your  
authorized dealer. The warranty registration card must be returned within fourteen days to register the warranty.  
NAPOLEON reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim.  
ALL SPECIFICATIONSAND DESIGNSARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® ISAREGISTERED  
TRADEMARK OF WOLF STEEL LTD. PATENTS U.S. 5.303.693.801 - CAN. 2.073.411, 2.082.915. © WOLF STEEL LTD.  
W415-0527/ 09.29.05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
SPECIFICATIONS  
GENERAL INSTRUCTIONS  
THE INSTALLATION MUST CONFORM WITH LOCAL  
CODES OR, IN THE ABSENCE OF LOCAL CODES WITH  
THE NATIONAL FUEL GAS CODE, ANSI Z223.1 / NFPA  
54 AND TO THE NATIONAL ELECTRICAL CODE, ANSI /  
NFPA 70.  
ZCVF36  
1 3/4”  
42.000”  
Use only accessories designed for and listed  
with your specic rebox.  
Not designed for use with a glass door.  
Screen must be closed when appliance is in  
operation.  
21 1/8”  
HOOD INSTALLATION  
31 7/8”  
Warning: Do not operate without hood in place.  
The rebox hood must not be modied or replaced with a  
hood that may be provided with the unvented decorative  
room heater.  
32 1/2”  
2
1
ZCVF42  
1 3/4”  
46 5/8”  
FIGURE 1  
Note: Remove the hood from the back side of the  
carton by cutting the cable ties holding it in place.  
1. Slide the edge of the hood into place on the top inside  
surface of the ventless rebox enclosure to align with the  
three pre-drilled holes.  
21 1/8”  
2. Screw the hood securely into place with the three screws  
provided. (FIGURE 1)  
36 3/8”  
35 1/2”  
W415-0527 / 09.29.05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
GAS INLET LOCATIONS  
There are ve gas inlet locations on the ventless rebox enclosure. One on each side of the unit, two at the rear, and one  
on the bottom. Using the following illustrations (FIGURE 2a-f) identify the preferred inlet and remove corresponding knock  
out.  
ZCVF36  
ZCVF42  
7”  
7”  
13 1/4”  
13 1/4”  
FIGURE 2a  
FIGURE 2b  
7”  
7”  
16 1/3”  
13”  
FIGURE 2c  
FIGURE 2d  
16 3/8”  
16 3/8”  
23 1/3”  
21”  
FIGURE 2e  
FIGURE 2f  
W415-0527/ 09.29.05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
FRAMING  
ANY CHANGE TO THIS ENCLOSURE CAN BE DANGEROUS AND IS PROHIBITED.  
It is best to frame your ventless rebox enclosure after it is positioned. Use 2x4’s and frame to local building codes.  
(FIGURE 3-5)  
ZCVF36  
ZCVF42  
FIGURE 3  
32 3/4"  
35 3/4"  
FIGURE 4  
52 1/3”  
55 5/8”  
42 1/2”  
74 1/8”  
47 1/8”  
78 5/8”  
FIGURE 5  
OUTSIDE  
CHASE  
OUTSIDE  
CHASE  
21 1/4"  
21 1/4"  
42 1/2"  
47 1/8"  
INSIDE  
CHASE  
INSIDE  
CHASE  
21 1/4”  
21 1/4”  
42 1/2”  
47 1/8”  
6"  
6"  
Minimum clearance to combustible construction from ventless firebox enclosure:  
sides, back, bottom and top of the unit  
recessed depth  
0 inches  
21 1/4 inches  
Note: In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the ventless rebox  
enclosure body, it is recommended that the walls of the ventless rebox enclosure enclosure be “nished” (ie: drywall/sheet-  
rock), as you would nish any other outside wall of a home. This will ensure that clearance to combustibles is maintained  
within the cavity.  
When roughing in the ventless rebox enclosure, raise the ventless rebox enclosure to accommodate for the thickness of  
the nished oor materials, i.e. tile, carpeting, hard wood.  
Objects placed in front of the ventless rebox enclosure should be kept a minimum of 4 feet away from the front face.  
W415-0527 / 09.29.05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
CORNER  
POST  
NAILING TAB INSTRUCTION  
1) Attach the nailing tabs to the corner posts using the 2  
sheet metal screws supplied. Secure through the centre of  
the top and bottom slots in the nailing tab and then through  
the existing holes in the corner posts.  
If there are no existing holes, follow these instructions:  
Position the nailing tab so that the front face is offset with  
the front edge of the corner post (approx. ½”). Centre the  
nailing tab vertically on the corner post. (FIGURE 6a) Drill  
through the centre of the top  
NAILING  
TAB  
TOP  
SLOT  
and bottom slots in the nailing  
tab. Secure using the two  
sheet metal screws supplied.  
This allows the nailing tab to  
slide back and forth for desired  
framing. (FIGURE 6b)  
2) To determine the nal  
location of the nailing tab you  
must rst determine the width  
of your nishing material (i.e.  
drywall). This will determine  
the dimension from the front  
edge of the corner post to the  
nailing tab. Once the nailing tab  
is in the desired location, drill  
through the centre hole of the  
nailing tab. Secure with a sheet  
metal screw*. (FIGURE 6c)  
* Additional set screws may be installed.  
FIGURE 6a  
FIGURE 6b  
MANTEL CLEARANCES  
Combustible materials may be installed ush with the front  
of the ventless rebox enclosure but must not cover any  
of the black face-areas of the ventless rebox enclosure.  
Non-combustible material (brick, stone or ceramic tile) may  
protrude in these areas.  
FINISHING MATERIAL  
Combustible mantel clearance can vary according to the  
mantel depth. Use the graph to help evaluate the clearance  
FIGURE 7  
MANTEL  
7"MANTLE  
COMBUSTIBLE  
MATERIALS  
MANTEL  
6"M
7"  
MANTEL  
4"MANTLE  
STUD  
6"  
4"  
TOP OF UNIT  
FIGURE 8  
CENTRE HOLE  
7
6
5
4
M
H  
E
I
A
N
G
H
T
T
E
L
4567  
MANTEL  
FIGURE 6c  
ME WIDTH  
W415-0527/ 09.29.05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
OPTIONAL BLOWER INSTALLATION  
INSTALLATIONTOBEDONEBYAQUALIFIEDINSTALLER  
and must be electrically connected and grounded in  
accordance with local codes. In the absence of local codes,  
use the current ANSI/NFPA 70 National Electrical Code.  
If the rebox was not previously equipped with a blower:  
route a grounded 2-wire, 60hz power cable through the  
junction plate cover. At this point it must be strain relieved  
and insulated.  
Secure to the threaded stud using the lock washer and  
wing nut provided. Ensure that the blower does not touch  
the rebox base or the rebox. (FIGURE 9) Attach the  
connectors from the black and red wires to the blower.  
The three slots on the blower mounting bracket allow ease  
of adjustment when attaching the blower. (FIGURE 10) For  
a quiet running blower, do not allow the assembly to sit on  
the rebox base.  
FIGURE 10  
S
a
T
i
The wire harness provided in this kit is a universal  
harness. When installed, ensure that any excess wire is  
contained, preventing it from making contact with moving  
or hot objects. Because the blower is thermally activated,  
when turned on, it will automatically start approximately  
30 minutes after lighting the vent free room heater and will  
run for approximately 30-45 after the vent free room heater  
has been turned off. Use of the fan increases the output of  
heat.  
B
Drywall dust will penetrate into the blower bearings  
causing irreparable damage. Care must be taken to  
prevent drywall dust from coming into contact with the  
blower or its compartment. Any damage resulting from this  
condition is not covered by the warranty policy.  
A
C
W415-0527 / 09.29.05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
Note: In either application it is necessary to remove the variable speed switch from the wiring harness and  
install into an electrical switch box as per electrical codes.  
WITH THERMAL SWITCH BRACKET  
WITHOUT THERMAL SWITCH BRACKET  
1. Remove the hearth pads and blower access cover.  
(FIGURE 9)  
1. Remove the hearth pads and the blower access cover.  
(FIGURE 9)  
2. Install the blower using the optional blower installation  
instructions.  
2. Install the blower using the optional blower installation  
instructions.  
3. Cut the red wire as close to the plug as possible.  
4. Cut the black wire as close to the ag connection as  
possible. (FIGURE 12).  
5. Using a box connector, connect supply wire though  
the junction cover plate located on the right side of the  
rebox enclosure.  
3. Pull the black and white thermal disc wires through the  
7/8” bushing in the blower access cover.  
4. Cut the white wire as close to the connector as  
possible. (FIGURE 11).  
5. Cut the red wire as close to the plug as possible.  
(FIGURE 11)  
6. Attach the ground to the ground screw on the junction  
plate cover.  
7. Replace the blower access cover plate and hearth  
pads.  
6. Using a box connector, connect supply wire through  
the junction cover plate located on the right sidce of  
the rebox enclosure.  
7. Connect the red and white wires to the power supply.  
Attach the ground to the ground screw on the junction  
plate cover.  
8. Replace the blower access cover.  
9. Attach the black & white wires to the back of the  
thermal switch and install at the rear of the rebox  
using the thermal switch support bracket as circled in  
(FIGURE 9).  
BLOWER  
BLACK  
10. Replace the hearth pads.  
RED  
BLOWER  
WHITE  
THERMAL DISC  
BLACK  
RED  
VARIABLE  
SPEED  
WHITE  
SWITCH  
FIGURE 12  
THERMAL DISC  
VARIABLE  
SPEED  
SWITCH  
FIGURE 11  
3
2
4
1
5
1. Hearth Pads  
2. Blower Access Cover  
3. Thermal Switch Support Bracket  
4. 7/8” Bushing  
5. Junction Box  
FIGURE 9  
W415-0527/ 09.29.05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10  
REPLACEMENTS  
Contact your dealer for questions concerning prices and  
availability of replacement parts. Normally all parts can be  
ordered through your Napoleon dealer or distributor.  
When ordering replacement parts always give the following  
information:  
1. Model & Serial Number of ventless rebox enclosure  
2. Installation date of ventless rebox enclosure  
FOR WARRANTY REPLACEMENT PARTS, A  
PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE  
REQUIRED TO HONOUR THE CLAIM.  
3. Part Number  
4. Description of part  
5. Finish  
ZCVF36  
ZCVF42  
REPLACEMENT PARTS  
REPLACEMENT PARTS  
#
1*  
2
3
4
5*  
6
7
PART No.  
DESCRIPTION  
Napoleon Logo  
Curtain Mesh  
Curtain Rod  
#
1*  
2
3
4
5*  
6
7
PART No.  
DESCRIPTION  
Napoleon Logo  
Curtain Mesh  
Curtain Rod  
W385-0245  
W565-0084  
W555-0056  
W335-0044  
W500-0192  
W475-0400  
W475-0386  
W385-0245  
W565-0085  
W555-0057  
W335-0045  
W500-0192  
W475-0399  
W475-0382  
Hood  
Hood  
Panel Brackets  
Hearth Pad (Right)  
Hearth Pad (Left)  
Panel Brackets  
Hearth Pad (Right)  
Hearth Pad (Left)  
ACCESSORIES  
ACCESSORIES  
#
8*  
PART No.  
111KT  
DESCRIPTION  
Outside Air Kit  
#
8*  
PART No.  
111KT  
DESCRIPTION  
111-KT Kit  
9*  
112KT  
Adaptor Plate, Outside Air Kit  
Brick Panels (Cobblestone)  
Decorative Door  
36” 3” Bevelled trim (textured black)  
36” 3” Bevelled trim (satin chrome)  
Blower kit  
9*  
112KT  
112 Collars  
Brick Panels (Cobblestone)  
Decorative Door  
42” 3” Bevelled trim (textured black)  
42” 3” Bevelled trim (satin chrome)  
Blower kit  
10*  
11  
12  
13*  
14  
15*  
GD810-KT  
DKZC36SS  
TBZC36K  
TBZC36SS  
GZ550-1KT  
W500-0033  
10*  
11  
12  
13*  
14  
15*  
GD809-KT  
DKZC42SS  
TBZC42K  
TBZC42SS  
GZ550-1KT  
W500-0033  
Switch Wall Mounting Plate  
Switch Wall Mounting Plate  
* IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED. FOR FURTHER INFORMATION, CONTACT YOUR NAPOLEON DEALER.  
7
6
W415-0527 / 09.29.05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
W415-0527/ 09.29.05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12  
NOTES  
W415-0527 / 09.29.05  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Washer W 340 User Manual
Milwaukee Cordless Drill LOK TOR II User Manual
MTD Lawn Mower Series 54M User Manual
Muratec Marine Radio IC F50 User Manual
National Instruments Computer Hardware PXI 8150 User Manual
National Instruments Network Card DP8400 User Manual
NETGEAR Network Router R6300 100NAS User Manual
Omega Thermometer A12P User Manual
Omnimount TV Mount WM4 L User Manual
P3 International Pest Control Equipment P7901 User Manual