		 INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.   
					CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS   
					GAS-FIRED DIRECT VENT INSERT   
					INSTALLATION AND OPERATION INSTRUCTIONS FOR:   
					VENTED GAS FIREPLACE   
					NATURAL GAS MODELS GDI-30N   
					PROPANE GAS MODELS GDI-30P   
					/ 
					WARNING: If the information in these instructions is not followed exactly, a fire   
					or explosion may result causing property damage, personal injury or death.   
					FOR YOUR SAFETY   
					Do not store or use gasoline or other flammable vapours and liquids in the   
					vicinity of this or any other appliance.   
					WHAT TO DO IF YOU SMELL GAS:   
					• Immediately call your gas supplier   
					from a neighbour's phone. Follow the   
					gas supplier's instructions.   
					• If you cannot reach your gas supplier,   
					call the fire department.   
					• Do not try to light any appliance.   
					• Do not touch any electrical switch.   
					• Do not use any phone in your   
					building.   
					Installation and service must be performed by a qualified installer, service   
					agency or the gas supplier.   
					Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031   
					
					W415-0384 / D / 09.13.05   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				3 
					NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized   
					ISO 9001:2000 Quality Assurance Certificate.   
					NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen   
					who take great pride in their work. The burner and valve assembly are leak and test-fired at a quality test   
					station. The complete fireplace is thoroughly inspected by a qualified technician before packaging to ensure that   
					you, the customer, receives the quality product that you expect from NAPOLEON.   
					NAPOLEON GAS FIREPLACE PRESIDENT'S LIFETIME LIMITED WARRANTY   
					The following materials and workmanship in your new NAPOLEON gas fireplace are   
					warranted against defects for as long as you own the fireplace. This covers: combustion   
					chamber, heat exchanger, stainless steel burner, phazer™ logs and embers, ceramic glass   
					(thermal breakage only), gold plated parts against tarnishing, porcelainized enamelled com-   
					ponents and aluminum extrusion trims.   
					Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,   
					thermal switch, switches, wiring, remote controls, ignitor, gasketing, and pilot assembly are   
					covered and NAPOLEON will provide replacement parts free of charge during the first year   
					of the limited warranty.   
					Labour related to warranty repair is covered free of charge during the first year. Repair   
					work, however, requires the prior approval of an authorized company official. Labour costs   
					to the account of NAPOLEON are based on a predetermined rate schedule and any repair   
					work must be done through an authorized NAPOLEON dealer.   
					CONDITIONS AND LIMITATIONS   
					NAPOLEON warrants its products against manufacturing defects to the original purchaser only -- i.e., the individual or legal entity (registered customer) whose name appears on the   
					warranty registration card filed with NAPOLEON -- provided that the purchase was made through an authorized NAPOLEON dealer and is subject to the following conditions and limitations:   
					This factory warranty is nontransferable and may not be extended whatsoever by any of our representatives.   
					The gas fireplace must be installed by a licenced, authorized service technician or contractor. Installation must be done in accordance with the installation instructions included with the   
					product and all local and national building and fire codes.   
					This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and parts installed from other manufacturers will nullify this   
					warranty.   
					This limited warranty further does not cover any scratches, dents, corrosion or discolouring caused by excessive heat, abrasive and chemical cleaners nor chipping on porcelain enamel   
					parts, mechanical breakage of PHAZER™ logs and embers, nor any venting components used in the installation of the fireplace.   
					NAPOLEON warrants its stainless steel burners against defects in workmanship and material for life, subject to the following conditions: During the first 10 years NAPOLEON will replace   
					or repair the defective parts at our option free of charge. From 10 years to life, NAPOLEON will provide replacement burners at 50% of the current retail price.   
					In the first year only, this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in   
					accordance with the operation instructions and under normal conditions.   
					After the first year, with respect to this President's Limited Lifetime Warranty, NAPOLEON may, at its discretion, fully discharge all obligations with respect to this warranty by refunding   
					to the original warranted purchaser the wholesale price of any warranted but defective part(s).   
					After the first year, NAPOLEON will not be responsible for installation, labour or any other costs or expenses related to the reinstallation of a warranted part, and such expenses are not   
					covered by this warranty.   
					Notwithstanding any provisions contained in this President's Limited Lifetime Warranty, NAPOLEON’S responsibility under this warranty is defined as above and it shall not in any event   
					extend to any incidental, consequential or indirect damages.   
					This warranty defines the obligations and liability of NAPOLEON with respect to the NAPOLEON gas fireplace and any other warranties expressed or implied with respect to this product,   
					its components or accessories are excluded.   
					NAPOLEON neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. NAPOLEON will not be responsible for:   
					over-firing, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting configurations,   
					insufficient makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.   
					Any damages to fireplace, combustion chamber, heat exchanger, brass trim or other component due to water, weather damage, long periods of dampness, condensation, damaging   
					chemicals or cleaners will not be the responsibility of NAPOLEON.   
					The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your authorized dealer. The warranty registration card   
					must be returned within fourteen days to register the warranty.   
					NAPOLEON reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim.   
					ALLSPECIFICATIONSAND DESIGNSARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® ISAREGISTERED   
					TRADEMARK OF WOLF STEELLTD. PATENTS U.S. 5.303.693.801 - CAN. 2.073.411, 2.082.915 & DES 417,497(12.07.1999). © WOLF STEELLTD.   
					W415-0384 / D / 09.13.05   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				4 
					GENERAL INSTRUCTIONS   
					GENERAL INFORMATION   
					THIS GAS FIREPLACE INSERT SHOULD BE INSTALLED cle. The grounding prong must not be removed from the   
					AND SERVICED BY A QUALIFIED INSTALLER to con- cord plug.   
					form with local codes. Installation practices vary from re- FOR YOUR SATISFACTION, THIS FIREPLACE INSERT   
					gion to region and it is important to know the specifics that HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION   
					apply to your area,   
					AND QUALITY!   
					for example: in Massachusetts State:   
					Minimum inlet gas supply pressure is 4.5 inches water   
					column for natural gas and 11 inches water column for   
					propane. Maximum inlet gas pressure is 7 inches water   
					column for natural gas and 13 inches water column for   
					propane. Manifold pressure under flow conditions is 3.5   
					inches water column for natural gas and 10 inches water   
					column for propane. When the fireplace is installed at el-   
					evations above 4,500ft, and in the absence of specific rec-   
					ommendations from the local authority having jurisdiction,   
					the certified high altitude input rating shall be reduced at   
					the rate of 4% for each additional 1,000ft.   
					• The fireplace damper must be removed or welded in the open   
					position prior to installation of a fireplace insert or gas log.   
					• The appliance off valve must be a “T” handle gas cock.   
					• The flexible connector must not be longer than 36 inches.   
					• The appliance is not approved for installation in a bedroom or   
					bathroom unless the unit is a direct vent sealed combustion   
					product.   
					• A carbon monoxide detector is required in all rooms containing   
					gas fired appliances.   
					• WARNING: This product must be installed by a licensed plumber   
					or gas fitter when installed within the commonwealth of   
					Massachusetts.   
					Expansion / contraction noises during heating up and cool-   
					ing down cycles are normal and to be expected.   
					In absence of local codes, install to the current CAN1-   
					B149 Installation Code in Canada or to the National Fuel   
					Gas Code, ANSI Z223.1, and NFPA 54 in the United   
					States. Mobile home installation must conform with local   
					codes or in the absence of local codes, install to the   
					current standard for gas equipped mobile housing CAN/   
					CSA Z240 MH Series in Canada or ANSI Z223.1 and NFPA   
					54 in the United States.   
					Purge all gas lines with the glass door of the fireplace   
					insert opened. Assure that a continuous gas flow is at   
					the burner before closing the door.   
					Maximum input is 24,500 BTU/hr for natural gas and pro-   
					pane. Maximum output for natural gas and propane is   
					20,825 BTU/hr at an efficiency of 85% with the fan on. The   
					maximum A.F.U.E. (annual fuel utilization efficiency) rating   
					is 82%. This fireplace insert is not approved for closet or   
					recessed installations. It is approved for bathroom, bed-   
					room and bed-sitting room installations and is suitable for   
					mobile homes. The natural gas model is suitable for in-   
					stallation in a mobile home that is permanently positioned   
					on its site and fuelled with natural gas.   
					This insert must be recessed into a vented noncombus-   
					tible wood-burning fireplace (prefabricated or masonry)   
					only. The minimum fireplace opening size in which the   
					heater is to be installed is:   
					Under extreme vent configurations, allow several min-   
					utes (5-15) for the flame to stabilize after ignition.   
					Objects placed in front of the fireplace must be kept a   
					minimum of 48" away from the front face of the unit.   
					HEIGHT 21.75" WIDTH 28" DEPTH 18"   
					The minimum allowable chimney flue size is 6" round.   
					The minimum distance, from the bottom of a combustible   
					mantle projecting 3" maximum from the wall to the top of   
					the louvre opening, is 12". A non-combustible hearth must   
					The fireplace insert and its individual shutoff valve must be   
					disconnected from the gas supply piping system during   
					any pressure testing of that system at test pressures in   
					excess of 1/2 psig (3.5 kPa). The fireplace insert must be   
					isolated from the gas supply piping system by closing its   
					individual manual shutoff valve during any pressure test-   
					ing of the gas supply piping system at test pressures equal   
					to or less than 1/2 psig (3.5 kPa).   
					A 1/8 inch NPT plug, accessible for test gauge connection,   
					must be installed immediately upstream of the gas supply   
					connection to the fireplace insert.   
					The fireplace insert must be electrically connected and   
					grounded in accordance with local codes. In the absence   
					of local codes, use the current CSA C22.1 CANADIAN ELEC-   
					TRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL   
					ELECTRICAL CODE in the United States. The blower power   
					cord must be connected into a properly grounded recepta-   
					CARE OF GLASS, AND PLATED PARTS   
					protrude a minimum of 18" from the unit unless the insert   
					is elevated a minimum of 12" above the combustible flooring.   
					Do not use abrasive cleaners to clean these parts. Buff   
					lightly with a clean dry cloth.   
					The glass is 3/16" ceramic glass available from your Na-   
					poleon / Wolf Steel Ltd. dealer. DO NOT SUBSTITUTE MA-   
					TERIALS. Clean the glass after the first 10 hours of opera-   
					tion with a recommended gas fireplace glass cleaner.   
					Thereafter clean as required. DO NOT CLEAN GLASS   
					W415-0384 / D / 09.13.05   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				5 
					INSTALLATION   
					WHEN HOT! If the glass is not kept clean permanent Clean out ashes from the inside of the wood-burning fire-   
					discolouration and / or blemishes may result.   
					place. Make sure that the chimney and wood-burning fire-   
					place are in a clean and sound condition and constructed   
					of non-combustible materials. If necessary have any repair   
					work done by a qualified person before installing the in-   
					sert. Remove the existing fireplace damper or lock into an   
					open position.   
					Using screws, attach the fireplace warning tag (W385-0199)   
					to the inside of the firebox of the fireplace into which the   
					insert is being installed.   
					Provide adequate ventilation air.   
					Provide adequate accessibility clearance for   
					servicing and operating the fireplace insert.   
					Never obstruct the front opening of the fire-   
					place insert.   
					Objects placed in front of the fireplace must   
					be kept a minimum of 48" away from the   
					front face of the unit.   
					WARNING: THIS FIREPLACE HAS BEEN CONVERTED FOR USE WITH   
					A 
					GAS   
					FIREPLACE INSERT ONLY AND CANNOT BE USED FOR BURNING WOOD OR SOLID   
					FUELS UNLESS ALL ORIGINAL PARTS HAVE BEEN REPLACED AND THE FIREPLACE   
					IS RE-APPROVED BY THE AUTHORITY HAVING JURISDICTION.   
					FIGURE 1 a-c   
					ATTENTION: CE FOYER A ETE CONVERTI AFIN D'ETRE UTILISE SEULEMENT COMME   
					FOYER ENCASTRE AU GAZ ET NE PEUT ETRE UTILSE POUR BRULER DU BOIS OU   
					TOUT AUTRE COMBUSTIBLE SOLIDE, SANS QUE TOUTES LES PIECES ORIGINALES   
					AIENT ETE REMPLACEES ET QUE LE FOYER SOIT APPROUVE DE NOUVEAU PAR   
					LES AUTORITES AYANT JURIDICTION.   
					W385-0199   
					The sheet-metal parts of the fireplace, in which the gas   
					fireplace insert is to be installed, must not be cut.   
					If the wood-burning factory-built fireplace has no gas   
					access hole(s) provided, an access hole of 1½ inch or   
					less may be drilled through the lower sides or bottom   
					of the fireplace in a proper workman like manner. This   
					access hole must be plugged with non-combustible in-   
					sulation after the gas supply line has been installed.   
					Ensure that existing chimney cleanouts fit properly.   
					The refractory, glass doors, screen rails, screen mesh   
					and log grates may be removed from the fireplace be-   
					fore installing the gas fireplace insert.   
					Smoke shelves, shields and baffles may be removed if   
					attached by mechanical fasteners.   
					The ventilation openings in the fireplace may be ob-   
					structed by the backer plates, aluminium trim etc. but   
					these parts are not to be applied so as to have an air-   
					tight seal.   
					W415-0384 / D / 09.13.05   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				6 
					3. INSIDE: Remove the securing screw from the front of the   
					vent mounting plate. Pull the vent mounting plate only, back   
					into the track, to the front stop. Start the slider back into   
					position. Re-secure the screw. The insert may now be   
					pushed into its final position inside the woodburning fire-   
					place, and the screw tightened until the slider has been   
					pulled tight to the front stop.   
					4. Route the flex liners through the slider. Attach and secure   
					the liners to the vent mounting plate using the same proce-   
					dure as before, ensuring that the marked exhaust liner is   
					attached to the exhaust collar.   
					INSERT VENT CONNECTION   
					Move the insert close to its final position inside the wood-   
					burning fireplace. This unit is equipped with 4 levelling   
					screws located in the four inside corners beneath the log   
					support. Level using the levelling screws to eliminate rock-   
					ing or excessive noise when the fan is in operation. Once   
					the unit is level, move it partially into place within the fire-   
					place to allow for all connections to be made. It is not prac-   
					tical to level the insert once it has been installed. Deter-   
					mine the required depth prior to installing the unit and ad-   
					just the four levelling screws accordingly.   
					CHIMNEY CONNECTION   
					Chimney installation must conform to both national and   
					local code requirements. The chimney must be lined with   
					one 2" or 3" diameter liner for intake and one 3" diameter   
					liner for exhaust. The minimum and maximum vent   
					lengths are 10 and 35 feet respectively. Recommended   
					Napoleon kits come in 3 lengths:   
					1-2" & 1-3" DOUBLE PLY ALUMINUM LINER-INLET AND EXHAUST &   
					2-3" TO 2" REDUCER:   
					GDI-2320KT   
					GDI-2325KT   
					GDI-2335KT   
					VENT KIT 20FT   
					VENT KIT 25FT   
					VENT KIT 35FT   
					2-3" DOUBLE PLY ALUMINUM LINER-INLET AND EXHAUST:   
					GDI-320KT   
					GDI-325KT   
					GDI-335KT   
					VENT KIT 20FT   
					VENT KIT 25 FT   
					VENT KIT 35 FT   
					While the liners must be continuous from the fireplace to   
					the chimney cap, to achieve the needed length, they may   
					be coupled, using an approved coupler.   
					We recommend that exhaust vents that pass through   
					unheated spaces, such as a garage or attic, be   
					wrapped in a protective sleeve to minimize condensa-   
					tion and reverse flow symptoms. See Trouble Shooting   
					for details.   
					This unit is approved for use with a 2" liner for air intake   
					and a 3" liner for exhaust. For best performance, how-   
					ever, it is recommended to use two 3" liners.   
					If a 2" liner is used for the intake, it may be necessary to   
					adjust the primary air shutter.   
					FIGURE3   
					GAS INSTALLATION   
					FIGURE 2   
					1. OUTSIDE: Slip the   
					one end of a liner a mini-   
					mum of 2" over the   
					sleeve of the air terminal.   
					Secure using 3 screws.   
					Then seal the joint and   
					screw heads with high   
					temperature sealant. Re-   
					peat with the other liner.   
					Install suitable supply piping connection to a flex connector   
					(as per local gas codes).   
					FIGURE4   
					WALL SWITCH / THERMOSTAT   
					NOTE: We recommend that the other end of the exhaust   
					liner be marked to eliminate the exhaust liner being con-   
					nected to the intake collar at the unit.   
					2. Gently stretch the liners to the required lengths and in-   
					sert into the chimney. Trim and fit the flashing plate to suit   
					the chimney termination. Place the air terminal onto the top   
					of the chimney. Make weather tight by sealing with caulking   
					(not supplied). Fasten to the chimney with screws and plugs   
					(not supplied).   
					For ease of accessibility, an optional remote wall switch   
					or millivolt thermostat may be installed in a convenient   
					location. Route 2-strand solid core millivolt wire from   
					the gas fireplace insert to the wall switch / millivolt ther-   
					mostat. The recommended maximum lead length de-   
					pends on the wire size: WIRE SIZE MAX. LENGTH   
					14gauge   
					16gauge   
					18gauge   
					100 feet   
					60 feet   
					40 feet   
					Do not connect either the wall switch, thermo-   
					stat or gas valve to electricity (110 VOLTS).   
					W415-0384 / D / 09.13.05   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				7 
					FINISHING   
					3. Place the bottom of the left crossover log (#4) against   
					the left firebox side and pulled forward to the grate.   
					The top of the log should rest in the pocket on the back log.   
					LOG PLACEMENT   
					PHAZERTM logs and glowing embers exclusive to Napoleon Fire-   
					places, provide a unique and realistic glowing effect that is   
					different in every installation. Take the time to carefully po-   
					sition the glowing embers for a maximum glowing effect.   
					Log colours may vary. During the initial use of the fireplace,   
					the colours will become more uniform as colour pigments   
					burn in during the heat activated curing process.   
					FIGURE 5a-d   
					4. Position the notch located on the end of the center log   
					(#5) against the middle grate post with the other end of the   
					log resting in the pocket of the left crossover log.   
					1. Place the back log (#1)   
					onto the log support tray and   
					behind the tabs. The tabs   
					TABS   
					maintain an air space be-   
					tween the log and the burner   
					to facilitate combustion air   
					flow. Ensure that the back   
					of the log rests against the   
					bracket on the back wall of the firebox.   
					5. Place the bottom of the right crossover log (#6) against   
					the right firebox side and pulled forward to the grate. The   
					top of the log should rest in the pocket provided on the   
					center log (#5).   
					OPTIONAL CHARCOAL EMBERS   
					Randomly place the charcoal embers along the front and   
					sides of the log support tray in a realistic manner. Fine   
					dust found in the bottom of the bag should not be used.   
					GLOWING EMBERS   
					2. Move the two small logs (#2 & #3) into position, lining   
					up the studs located on the burner with the holes on the   
					bottom of the logs. Ensure that the small logs sit flat on the   
					burner.   
					Tear the embers into pieces and place along the front row   
					of ports covering all of the burner area in front of the small   
					logs (#2 & #3). Care should be taken to shred the embers   
					into thin, small irregular pieces as only the exposed edges   
					of the fibre hairs will glow. The ember material will only   
					glow when exposed to direct flame; however, care   
					should be taken to not block the burner ports.   
					Blocked burner ports can cause an incorrect flame pattern,   
					carbon deposits and delayed ignition. PHAZERTM logs glow   
					when exposed to direct flame. Use only certified "glowing   
					embers" and PHAZERTM logs available from your Napo-   
					leon dealer.   
					W415-0384 / D / 09.13.05   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				8 
					DOOR OPERATION   
					MANTLE CLEARANCE   
					The upper louvres must be removed to allow the door to be   
					opened or closed. Release the top and bottom door latches,   
					located at the right side of the door.   
					This can vary according to the mantle depth. Use the graph   
					to help evaluate the clearance needed.   
					FIGURE 6   
					FIGURE 7   
					DOOR LATCH   
					H 
					E 
					I 
					G 
					H 
					T 
					M 
					A 
					N 
					T 
					L 
					E 
					MANTLE WIDTH   
					OPERATION / MAINTENANCE   
					When lit for the first time, the fireplace will emit a slight   
					OPERATING INSTRUCTIONS   
					odour for a few hours. This is a normal temporary con-   
					dition caused by the "burn-in" of paints and lubricants   
					used in the manufacturing process and will not occur   
					again. Simply open a window to sufficiently ventilate   
					the room. After extended periods of non-operation such   
					as following a vacation or a warm weather season, the   
					fireplace may emit a slight odour for a few hours. This   
					is caused by dust particles in the heat exchanger burn-   
					ing off. Open a window to sufficiently ventilate the room.   
					PURGE THE GAS LINE WITH THE GLASS DOOR OPEN.   
					Purge all gas lines with the glass door open. Assure   
					that a continuous gas flow is at the burner before clos-   
					ing the door. Allow several minutes (5-15) for the flame   
					to stabilize after ignition.   
					Do not operate the main burner of the in-   
					sert with the door opened.   
					W415-0384 / D / 09.13.05   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				9 
					FOR YOUR SAFETY READ BEFORE LIGHTING:   
					WHAT TO DO IF YOU SMELL GAS:   
					• Turn off all gas to the fireplace.   
					A. This fireplace is equipped with a pilot which must be lit   
					by hand. While following these instructions exactly.   
					B. Before operating smell all around the fireplace area for   
					gas and next to the floor because some gas is heavier   
					than air and will settle on the floor.   
					C. Use only your hand to turn the gas control knob. Never   
					use tools. If the knob will not turn by hand, do not try to   
					repair it. Call a qualified service technician. Force or at-   
					tempted repair may result in a fire or explosion.   
					D. Do not use this fireplace if any part has been under water.   
					Immediately call a qualified service technician to inspect   
					the fireplace and replace any part of the control system   
					and any gas control which has been under water.   
					• Open windows.   
					• Do not try to light any appliance.   
					• Do not touch any electric switch; do not use any phone in   
					your building.   
					• Immediately call your gas supplier from a neighbour's   
					phone. Follow the gas supplier's instructions.   
					• If you cannot reach your gas supplier, call the fire depart-   
					ment.   
					FLAME   
					PILOT   
					ADJUSTMENT   
					ON/OFF   
					KNOB   
					KNOB   
					LIGHTING INSTRUCTIONS   
					When lighting and re-lighting, the gas knob cannot be turned   
					from pilot to off unless the knob is depressed slightly.   
					1. Stop! Read the above safety information on this label.   
					2. Turn off all electric power to the fireplace.   
					7. Depress slightly and hold gas knob while lighting the pilot   
					with the push button ignitor. Keep knob depressed for one   
					minute, then release. If pilot does not continue to burn, re-   
					peat steps 3 through 7.   
					8. With pilot lit, depress and turn gas knob counter-clock-   
					wise to on.   
					9. If equipped with flame adjustment valve, push and turn   
					knob to high.   
					10. If equipped with remote on-off switch/thermostat, main   
					burner may not come on when you turn valve to on. Remote   
					switch must be in the on position to ignite burner.   
					11. Turn on all electric power to the fireplace.   
					3. Turn the gas knob clockwise to off.   
					4. Wait five (5) minutes to clear out any gas. If you smell gas   
					including near the floor. Stop! Follow "B" in the above safety   
					information on this label. If you don't smell gas go the next step.   
					5. Find pilot located in front of back log.   
					6. Turn gas knob counter-clockwise to pilot.   
					TO TURN OFF GAS   
					1. Turn off all electrical power to the unit if service is to be 2. Push in gas control knob slightly and turn clockwise to   
					performed.   
					off. Do not force.   
					MAINTENANCE   
					TURN OFF THE GAS AND UNPLUG ELECTRICAL   
					POWER BEFORE SERVICING THE FIREPLACE   
					INSERT!   
					2. Keep the control compartment, logs, burner, air shutter   
					opening and the area surrounding the logs clean by vacu-   
					uming or brushing, at least once a year.   
					CAUTION: Label all wires prior to disconnection when   
					servicing controls. Wiring errors can cause improper and   
					dangerous operation. Verify proper operation after servic-   
					ing. This insert and its venting system should be in-   
					spected before use and at least annually by a qualified   
					service person. The fireplace area must be kept clear   
					and free of combustible materials, gasoline or other flam-   
					mable vapours and liquids. The flow of combustion and   
					ventilation air must not be obstructed.   
					3. Check to see that all burner ports are burning. Clean out   
					any of the ports which may not be burning or are not burn-   
					ing properly.   
					4. Check to see that the pilot flame is large enough to engulf   
					the thermocouple on one leg and reaches toward the   
					burner on the other leg.   
					5. Replace the cleaned logs.   
					6. Check to see that the main burner ignites completely on   
					all openings when the gas knob for the burner is turned   
					on. A 5-10 second total light-up period is satisfactory. If   
					ignition takes longer, consult your Napoleon dealer/dis-   
					tributor.   
					1. In order to properly clean the burner and pilot assembly,   
					remove the logs exposing both assemblies.   
					7. Check that the door gasketing is not broken or missing.   
					Replace if necessary.   
					Remove the pilot screw cap. Adjust the pilot screw to pro-   
					vide properly sized flame. Turn in a clockwise direction to   
					reduce the gas flow. Replace the pilot screw cap.   
					1 
					Natural gas has the air shutter set at /4" opening; pro-   
					pane has the air shutter set at 3/8" opening. Closing the air   
					W415-0384 / D / 09.13.05   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				10   
					BLOWER REPLACEMENT INSTALLATION   
					1. Turn off the electri-   
					cal power and the gas   
					supply to the fireplace   
					insert.   
					FIGURE 11   
					2. Open the glass door   
					and remove the logs   
					and fibre bricks, if in-   
					stalled.   
					FIGURE 8   
					FIGURE 9   
					BLOWER ACCESS COVER   
					THERMODISC / BRACKET ASSEMBLY   
					damaged.   
					5. Disconnect the two blower wires. Remove the blower   
					from the mounting plate and replace.   
					For thermodisc replacement: Remove the mounting   
					bracket secured to the underside of the burner base. Re-   
					move the thermodisc from the bracket and replace.   
					6. Reconnect the two wires. Re-install the blower gasket.   
					Reattach the blower mounting plate and blower access   
					cover. Replace the logs. Close the fire viewing door.   
					7. Turn the gas supply and electricity back on.   
					3. Remove the blower access cover held on with 4 screws.   
					FIGURE 10   
					BLOWER ACCESS COVER REMOVED   
					Because the blower is thermally activated, when turned on,   
					it will automatically start approximately 5-15 minutes after   
					lighting the fireplace insert and will run for approximately   
					30-45 minutes after the fireplace insert has been turned   
					off. Use of the fan increases the output of heat.   
					MOUNTING   
					PLATE   
					Drywall dust will penetrate into the blower bearings caus-   
					ing irreparable damage and must be prevented from com-   
					ing into contact with the blower or its compartment. Any   
					damage resulting from this condition is not covered by the   
					warranty policy.   
					4. Remove the blower mounting plate with the blower   
					attached.   
					NOTE: Check the blower gasket for damage. Replace if   
					ADJUSTMENTS   
					PILOT BURNER ADJUSTMENT   
					VENTURI ADJUSTMENT   
					The flame may not appear yellow immediately; allow 15 to   
					30 minutes for the final flame colour to be established.   
					shutter will cause a more yellow flame, but can lead to   
					carboning. Opening the air shutter will cause a more blue   
					flame, but can cause flame lifting from the burner ports.   
					I 
					FIGURE 14   
					PILOT SCREW   
					FIGURE 13   
					FIGURE 12   
					Air shutter adjustment must only be done by a qualified   
					gas installer!   
					W415-0384 / D / 09.13.05   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				11   
					REPLACEMENTS   
					Contact your dealer for questions concerning prices and When ordering replacement parts always give the follow-   
					availability of replacement parts. Normally all parts can be ing information:   
					ordered through your Napoleon dealer or distributor.   
					1. MODEL & SERIAL NUMBER OF FIREPLACE   
					2. INSTALLATION DATE OF FIREPLACE   
					3. PART NUMBER   
					4. DESCRIPTION OF PART   
					5. FINISH   
					FOR WARRANTY REPLACEMENT PARTS, APHOTOCOPY OF THE   
					ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM.   
					ACCESSORIES:   
					REPLACEMENT PARTS   
					# 
					PART NO. DESCRIPTION   
					GI-1LK   
					# 
					1 
					2 
					2 
					3 
					3 
					4 
					5 
					6 
					7 
					7 
					8 
					9 
					10   
					11   
					12   
					13   
					14   
					15   
					16   
					17   
					18   
					19   
					19   
					20   
					21   
					22   
					23   
					24   
					PART # DESCRIPTION   
					GZ552   
					28   
					28   
					28   
					28   
					BLACK UPPER & LOWER LOUVRES   
					REPLACEMENT BLOWER   
					NATURAL GAS VALVE   
					GI-1LPB   
					GI-1LAB   
					GI-1LSS   
					BLACK UPPER & POLISHED BRASS LOWER LOUVRES   
					BLACK UPPER & ANTIQUE BRASS LOWER LOUVRES   
					BLACK UPPER & BRUSHED STAINLESS STEEL   
					LOWER LOUVRES   
					W725-0035   
					W725-0026   
					W455-0019   
					W455-0003   
					W357-0001   
					W680-0004   
					W680-0005   
					W010-0801   
					W010-0800   
					W690-0002   
					W660-0009   
					W135-0183   
					W135-0184   
					W135-0185   
					W135-0186   
					W135-0187   
					W135-0188   
					GL-639   
					PROPANE GAS VALVE   
					#43 NATURAL GAS BURNER ORIFICE   
					#54 PROPANE GAS BURNER ORIFICE   
					PIEZO IGNITER   
					THERMOPILE   
					THERMOCOUPLE   
					NATURAL GAS PILOT ASSEMBLY   
					PROPANE GAS PILOTASSEMBLY   
					THERMAL SENSING SWITCH   
					BURNER ON/OFF SWITCH   
					REAR LOG (#1)   
					LEFT MIDDLE LOG (#2)   
					RIGHT MIDDLE LOG (#3)   
					LEFT CROSSOVER LOG (#4)   
					MIDDLE CROSSOVER LOG (#5)   
					RIGHT CROSSOVER LOG (#6)   
					LOG SET   
					28   
					29   
					GI-1LG   
					GI-OIK   
					GOLD PLATED UPPER & LOWER LOUVRES   
					BLACK UPPER & LOWER INSET W/ POLISHED   
					BRASS LOWER DOOR TRIM   
					29   
					30   
					31   
					31   
					31   
					31   
					31   
					32   
					32   
					33   
					33   
					33   
					33   
					34   
					34   
					34   
					35   
					35   
					35   
					35   
					36   
					36   
					36   
					37   
					37   
					37   
					GI-OIG   
					GOLD PLATED UPPER & LOWER INSET   
					BAY FRONT COMPLETE WITH PULL SCREEN   
					BLACK LOUVRES   
					POLISHED BRASS LOWER LOUVRES   
					ANTIQUE BRASS LOWER LOUVRES   
					BRUSHED STAINLESS STEEL LOWER LOUVRES   
					GOLD PLATED LOWER LOUVRES   
					BLACK LOWER INSET   
					GI30B-KT   
					GIB-1LK   
					GIB-1LPB   
					GIB-1LAB   
					GIB-1LSS   
					GIB-1LG   
					GIB-1OIK   
					GIB-1OIG   
					GI-900K6   
					GI-900B6   
					GI-900AB6   
					GI-900SS6   
					GI-909S6   
					GI-909K6   
					GI-909F6   
					GI-900K9   
					GI-900B9   
					GI-900AB9   
					GI-900SS9   
					GI-909S9   
					GI-909K9   
					GI-909F9   
					CISK   
					GOLD PLATED LOWER INSETS   
					6" BLACK WITH MARQUIS TRIM   
					6" POLISHED BRASS WITH MARQUIS TRIM   
					6" ANIQUE BRASS WITH MARQUIS TRIM   
					6" BRUSHED STAINLESS STEEL BLACK TRIM   
					6" PORCELAIN ALMOND WITH MARQUIS TRIM   
					6" PORCELAIN BLACK WITH MARQUIS TRIM   
					6" PORCELAIN GREEN WITH MARQUIS TRIM   
					9" BLACK WITH MARQUIS TRIM   
					9" POLISHED BRASS WITH MARQUIS TRIM   
					9" ANTIQUE BRASS WITH MARQUIS TRIM   
					9" BRUSHED STAINLESS STEEL WITH BLACK TRIM   
					9" POCELAIN ALMOND WITH MARQUIS TRIM   
					9" PORCELAIN BLACK WITH MARQUIS TRIM   
					9" PORCELAIN GREEN WITH MARQUIS TRIM   
					CAST SURROUND PAINTED BLACK   
					CAST SURROUND PORCELAIN ENAMEL BLACK   
					CAST SURROUND PORCELAIN ENAMEL   
					MAJOLICA BROWN   
					W361-0016   
					W010-1046   
					W455-0070   
					W455-0068   
					W385-0245   
					W562-0008   
					KB-35   
					GLOWING EMBERS   
					BURNER ASSEMBLY   
					NATURAL GAS PILOT INJECTOR   
					PROPANE GAS PILOT INJECTOR   
					NAPOLEON LOGO   
					GLASS GASKET   
					VARIABLE SPEED SWITCH   
					GLASS W/ GASKET   
					W010-1095   
					W010-1042   
					DOOR, GLASS & GASKETASSEMBLY   
					TERMINAL KITS   
					25   
					GDI-223   
					TERMINAL   
					CISKK   
					CISKN   
					VENT KITS   
					37   
					37   
					CISKB   
					CISKF   
					CAST SURROUND PORCELAIN ENAMEL   
					MAJOLICA BLUE   
					CAST SURROUND PORCELAIN ENAMEL   
					MAJOLICA GREEN   
					1-2" & 1-3" DOUBLE PLY ALUMINUM LINER-INLET AND EXHAUST &   
					2-3" TO 2" REDUCER:   
					26   
					26   
					26   
					GDI-2320KT   
					GDI-2325KT   
					GDI-2335KT   
					VENT KIT 20FT   
					VENT KIT 25FT   
					VENT KIT 35FT   
					38   
					39   
					40   
					41   
					42   
					42   
					43   
					44   
					45   
					45   
					46   
					W690-0001   
					W660-0011B   
					GD-660   
					W660-0026   
					ANI-K   
					MILLIVOLTTHERMOSTAT   
					REMOTE CONTROL - ADVANTAGE PLUS   
					REMOTE WALL SWITCH WITH 20" WIRE   
					TIMER, BATTERY OPERATED   
					ANDIRONS - BLACK   
					ANDIRONS - GOLD PLATED   
					DECORATIVE BRICK PANELS   
					6" BEVELLED FLASHING - BLACK   
					TRIM FOR BEVELLED FLASHING - BLACK   
					TRIM FOR BEVELLED FLASHING - POLISHED BRASS   
					RISER BOX - PAINTED BLACK   
					2-3" DOUBLE PLY ALUMINUM LINER-INLET AND EXHAUST:   
					ANI-G   
					27   
					27   
					27   
					GDI-320KT   
					GDI-325KT   
					GDI-335KT   
					VENT KIT 20FT   
					VENT KIT 25 FT   
					VENT KIT 35 FT   
					GI-798KT   
					GI-910K   
					GI-942K   
					GI-942B   
					GI-RB   
					47* W175-0218   
					47* W175-0216   
					CONVERSION KIT - LP-NG   
					CONVERSION KIT - NG-LP   
					W415-0384 / D / 09.13.05   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				12   
					W415-0384 / D / 09.13.05   
					* WARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with   
					a fast acting thermocouple supplied by Wolf Steel Ltd.   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				13   
					TROUBLE SHOOTING GUIDE   
					BEFORE ATTEMPTING TO TROUBLESHOOT, PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR OPEN.   
					SYMPTOM   
					PROBLEM   
					TEST SOLUTION   
					No spark at pilot burner   
					- check if pilot can be lit by a match   
					Pilot will not light.   
					- check that the wire is connected to the push button ignitor.   
					- check if the push button ignitor needs tightening.   
					- replace the push button ignitor.   
					- spark gap should be 0.150" to 0.175" (5/32" to 11/64" approx.)   
					from the electrode tip and the pilot burner.   
					Spark gap is incorrect   
					No gas at the pilot burner   
					- check that the manual valve is turned on.   
					- check the pilot orifice for blockage.   
					- replace the valve.   
					- call the gas distributor.   
					Out of propane gas.   
					- fill the tank.   
					- purge the gas line with the glass door open.   
					Pilot goes out when   
					the gas knob is re-   
					leased.   
					System is not correctly purged.   
					Out of propane gas   
					- fill the tank.   
					Pilot flame is not large enough   
					- turn up the pilot flame.   
					Pilot flame is not engulfing the - turn up pilot flame.   
					thermocouple.   
					- 
					replace pilot assembly.   
					- loosen and tighten thermocouple.   
					- clean thermocouple and valve connection.   
					- replace thermocouple.   
					Thermocouple shorting.   
					- replace valve.   
					Faultly thermocouple.   
					Faulty valve.   
					- replace.   
					- replace.   
					- remove stoppage in orifice.   
					- replace.   
					Pilot burning; no gas Main burner orifice is plugged.   
					to main burner; gas   
					knob is on 'HI'; wall   
					Faulty themostat or switch.   
					switch / thermostat is   
					Faulty thermopile.   
					- connect a jumper wire across the wall switch terminals; if   
					main burner lights, replace thermostat.   
					on.   
					- disconnect the switch wires & connect a jumper wire across   
					terminals 1 & 3; if the main burner lights, check the wires for   
					defects and / or replace wires.   
					Faulty valve.   
					- replace.   
					- 
					turn on all gas appliances and see if pilot flame flutters,   
					Gas piping is undersized.   
					Pilot goes out while   
					standing; Main burner   
					is in 'OFF' position.   
					diminishes or extinguishes, especially when main burner ig-   
					nites. Monitor supply pressure.   
					- check if supply piping size is to code. Correct all undersized   
					piping.   
					Pilot flame is not large enough - turn up pilot flame.   
					or not engulfing the thermopile. - replace pilot assembly.   
					Main burner goes out;   
					pilot stays on.   
					- clean thermopile and thermopile connection to valve.   
					Thermopile shorting   
					Remote wall switch wire is too   
					long, too much resistance in   
					the system   
					- shorten wire to correct length or wire gauge.   
					- replace   
					Faulty thermostat or switch   
					W415-0384 / D / 09.13.05   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				14   
					SYMPTOM   
					PROBLEM   
					TEST SOLUTION   
					REFER TO "MAIN BURNER GOES OUT; PILOT STAYS ON"   
					Main burner goes out;   
					pilot goes out.   
					Vent re-circulating   
					- check joint seals and installation.   
					Thermocouple shorting or   
					faulty.   
					- loosen and tighten thermocouple   
					- clean thermocouple and valve connection.   
					- replace thermocouple.   
					- replace valve.   
					Vent is reversing   
					- check all venting and insert seals.   
					- check that door is properly sealed. If the insert is allowed to   
					burn with the door open when purging the unit, exhaust products   
					may reverse the venting action. Let the unit cool down to correct   
					the reversed venting action.   
					Exhaust   
					fumes   
					- check all seals.   
					Fireplace is spilling.   
					smelled in room,   
					headaches.   
					Carbon is being de- Air shutter has become   
					posited on glass, blocked   
					- ensure air shutter opening is free of lint or other obstruc-   
					tions.   
					logs or combustion   
					chamber surfaces.   
					Flame is impinging on the - check that the logs are correctly positioned.   
					logs or combustion chamber. - open air shutter to increase the primary air.   
					- check the input rate: check the manifold pressure and orifice   
					size as specified by the rating plate values.   
					- check that the door gasketing is not broken or missing and   
					that the seal is tight.   
					- check that both vent liners are free of holes and well sealed at   
					all joints.   
					Main burner flame is Blockage in vent.   
					a blue, lazy, transpar-   
					- remove blockage. In really cold conditions, ice buildup may   
					occur on the terminal and should be removed as required.   
					ent flame.   
					- vent liners are reversed. Refer to Figures 2 & 3.   
					- check all venting and insert seals.   
					Incorrect installation.   
					Sulphur from fuel is being de- - clean the glass with a recommended gas fireplace glass   
					posited on glass, logs or com- cleaner. DO NOT CLEAN GLASS WHEN HOT.   
					White / grey film   
					forms.   
					bustion chamber surfaces.   
					If deposits are not cleaned off regularly, the glass may be-   
					come permanently marked.   
					Flames are very   
					aggressive.   
					Door is ajar   
					-ensure door seal is tight.   